Davita Bayonne
A dialysis facility in Bayonne, New Jersey 07002
434-436 Broadway, Bayonne, New Jersey 07002. (201) 436-1664.
Watch and the shortlist are kept with a free account, on every device. Your watch list. CMS’s own record is on Care Compare.
The short answer
Record last released by CMS on Oct 14, 2026.
- 5of 5 CMS’s star rating
- Not rated patient survey rating
- 4 deficiencies cited in the last three years
- 21 dialysis stations
Each figure’s source sits beside it, in its section below.
What these words mean3
- Star ratings
- CMS rates some kinds of place from 1 to 5 stars, more stars meaning better on CMS’s own measures for that kind: for a nursing home, its health inspections, staffing and quality measures. A rating is CMS’s summary of those measures; it doesn’t promise good care. Source: CMS, Care Compare and the Five-Star Quality Rating System.
- Inspection (survey)
- A visit by state inspectors, often unannounced, who check a place against the rules it must meet. For nursing homes and other places Medicare pays, CMS calls these visits surveys: a standard survey of a nursing home comes at least every 15 months, and a complaint survey whenever a complaint calls for one. Source: CMS; 42 CFR 488.308.
- Deficiency, citation, violation
- What inspectors write up when a place didn’t meet a rule: the rule, what they saw, and when. CMS calls it a deficiency; states may say citation or violation. It is the inspectors’ finding, not a court’s, and the place is usually asked for a plan to correct it. Source: CMS, statement of deficiencies (Form CMS-2567); each state’s licensing agency.
What did inspectors find?
The last inspection on record was on Nov 29, 2023: a standard inspection.
4 deficiencies cited in the last three years.
CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 14, 2026. Updated monthly.
When those deficiencies happened
4 deficiencies in 1 month of the last 36. Last cited Nov 2023. Most serious: Standard-level. The last 3 years, to Oct 19, 2026.
| Jan | Feb | Mar | Apr | May | Jun | Jul | Aug | Sep | Oct | Nov | Dec | |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 2023 | Nov | Dec | ||||||||||
| 2024 | Jan | Feb | Mar | Apr | May | Jun | Jul | Aug | Sep | Oct | Nov | Dec |
| 2025 | Jan | Feb | Mar | Apr | May | Jun | Jul | Aug | Sep | Oct | Nov | Dec |
| 2026 | Jan | Feb | Mar | Apr | May | Jun | Jul | Aug | Sep | Oct |
Hover or focus a month to read it.
Hearth Record drew this from the dates and levels in the source’s own records.
Each deficiency, as cited
Rule titles as CMS’s inspectors cite them, set in sentence case.
CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 14, 2026. Updated monthly.
Nov 29, 2023: standard inspection4 deficiencies
-
Dialysis Emergency Equipment
The inspectors’ words, 315 words
“Dialysis Emergency Equipment CFR(s): §494.62(b)(9) Condition for Coverage: [(b) Policies and procedures. The dialysis facility must develop and implement emergency preparedness policies and procedures, based on the emergency plan set forth in paragraph (a) of this section, risk assessment at paragraph (a)(1) of this section, and the communication plan at paragraph (c) of this section. The policies and procedures must be reviewed and updated at least every 2 years. At a minimum, the policies and procedures must address the following:] (9) A process by which the staff can confirm that emergency equipment, including, but not limited to, oxygen, airways, suction, defibrillator or automated external defibrillator, artificial resuscitator, and emergency drugs, are on the premises at all times and immediately available. This Standard is not met as evidenced by: 48966 Based on observation, staff interview, and review of facility documentation, it was determined the facility failed to ensure that the emergency evacuation box contained patient treatment orders and were updated monthly for 53 of 53 hemodialysis patients. Findings include: During an observation of the emergency evacuation box on 11/27/23 at 1:12 PM, a binder containing patient treatment orders and medication lists were noted within the box. The treatment orders and medication lists were dated 2/3/23. On 11/27/23 during an interview at 1:34 PM, Staff (S)2, the Clinical Coordinator (CC), stated the patient’s treatment orders and medication lists are updated quarterly by the Administrative Assistant. On 11/27/23 during an interview at 2:33 PM, Staff (S)1, the Facility Administrator (FA), explained that the patient’s treatment orders and medication lists should be updated monthly. S1 provided the emergency evacuation box policy. Review of the facility policy titled, “Facility Emergency Management Plan,” revised in October 2023, stated....”Emergency Evacuation Kit...6. Each evacuation kit(s) should contain: a. Copy of each patient’s treatment orders and medication list. FA or designee will verify patient information is updated and replaced at least monthly.” N.J.A.C. 8:43A-15.1(d)”
-
Pe - Building - Constructed/Maintained To Ensure Safety
The inspectors’ words, 230 words
“PE-BUILDING-CONSTRUCT/MAINTAIN FOR SAFETY CFR(s): 494.60(a) The building in which dialysis services are furnished must be constructed and maintained to ensure the safety of the patients, the staff and the public. This Standard is not met as evidenced by: 33557 Based on observation and staff interview on 11/28/23, it was determined that: 1. the ceiling tiles surrounding ten (10) of ten (10) heating and air conditioning discharge louvers, mounted on the ceiling throughout the Hemodialysis Treatment floor, are discolored and stained; and 2. the exhaust fan in the Janitor’s Closet is disconnected and should be remounted. Findings include: 1. During a tour of the Treatment Floor at 11:05 AM, white ceiling tiles surrounding ten (10) of ten (10) heating and air conditioning discharge louvers, mounted on the ceiling of the treatment floor, were visibly dirty and stained gray. During an interview at 11:05 AM, Staff #8 stated, “Those ceiling tiles need to be changed out. They look dirty.” 2. On 11/28/23 at 10:30 AM in the Janitor’s Closet, the exhaust fan that was previously mounted on the ceiling, was found resting on the top shelf on its side, still running. The exhaust fan was no longer connected to the exhaust ductwork which exhausted air to the outside. The frame, which held the fan in place, was still hanging from the ceiling grid. During an interview, Staff #8 confirmed the above finding.”
-
Pe - Equipment Maintenance - Manufacturer’S Dfu
The inspectors’ words, 135 words
“PE-EQUIPMENT MAINTENANCE-MANUFACTURER’S DFU CFR(s): 494.60(b) The dialysis facility must implement and maintain a program to ensure that all equipment (including emergency equipment, dialysis machines and equipment, and the water treatment system) are maintained and operated in accordance with the manufacturer’s recommendations. This Standard is not met as evidenced by: 33557 Based on observation and staff interview on 11/28/23, it was determined the facility failed to ensure the toilet paper dispenser in the patient toilet is maintained for one of one patient toilets on the treatment floor. Findings include: During a tour of the Treatment Floor at 10:45 AM, the toilet paper dispenser in the patient toilet, on the Treatment Floor, was apart with the front cover lying on the floor. During an interview at 10:45 AM, Staff #8 stated, “That should not be like that.””
-
Achieve Adequate Clearance
The inspectors’ words, 468 words
“POC-ACHIEVE ADEQUATE CLEARANCE CFR(s): 494.90(a)(1) Achieve and sustain the prescribed dose of dialysis to meet a hemodialysis Kt/V of at least 1.2 and a peritoneal dialysis weekly Kt/V of at least 1.7 or meet an alternative equivalent professionally-accepted clinical practice standard for adequacy of dialysis. This Standard is not met as evidenced by: 39228 Based on medical record review and staff interview, it was determined the facility failed to ensure that one of seven patients (Patient (P) 1) received his/her hemodialysis treatments in accordance with the physician prescribed dialysis order. Findings include: A review of P1’s medical record revealed the following: “Orders,” dated 11/8/23, included an order for a dialysis flow rate (DFR) of “600.” On 11/8/23, the “Treatment Details Report” indicated P1 was dialyzed with a DFR of 500 instead of the prescribed DFR of 600 from the initiation of the treatment at 11:16 AM until the end of the treatment at 14:17 (2:17 PM), three hours and 1 minute later. The medical record lacked documented evidence of a rationale for a lower DFR rate of 500. On 11/13/23, the “Treatment Details Report” indicated that P1 was dialyzed with a DFR of 500 instead of the prescribed DFR of 600 from the initiation of the treatment at 10:59 AM until the end of the treatment at 14:02 (2:07 PM), three hours and three minutes later. The medical record lacked documented evidence of a rationale for a lower DFR rate of 500. “Orders,” dated 11/22/23, included an order for a dialysis flow rate (DFR) of “600.” On 11/22/23, the “Treatment Details Report” indicated that P1 was dialyzed with a DFR of 500 instead of the prescribed DFR of 600, from the initiation of the treatment at 10:56 AM until the end of the treatment at 14:02 (2:02 PM), three hours and six (6) minutes later. The medical record lacked documented evidence of a rationale for a lower DFR rate of 500. During an interview on 11/28/23 at 11:45 AM, the above findings were reviewed with Staff (S) 2, a Registered Nurse. S2 stated that the DFR was ordered at 600 on the above dates and that the staff should be running it at 600 not 500. The above findings are not in accordance with the prescribed orders. A review of facility policy titled, “Interdisciplinary Team (IDT) Patient Assessment and Plan of Care,” revised April 2023, stated, “... PLAN OF CARE: 8. The facility’s interdisciplinary team will develop and implement a written, individualized comprehensive plan of care that specifies the services necessary to address the patient’s needs ... 9. The plan of care will address, but not be limited to, the following: Dose of dialysis which addresses care and services to manage the patient;s volume status; and achieve and sustain the prescribed dose of dialysis ...” N.J.A.C. 8:43A-24.13 (b)”
The one inspection in the last three years
| Date | Visit | What the record says |
|---|---|---|
| Nov 29, 2023 | Standard inspection | 4 deficiencies cited |
Is it certified?
- Medicare-certified dialysis facility, certified or last recertified on Apr 23, 2002.
- Run for profit.
- No For hospices, home health agencies, hospitals and dialysis facilities, CMS writes deficiencies at two levels. Standard is the usual one; condition-level is the more serious, when a problem is serious enough that the provider doesn’t meet a whole condition of taking part in Medicare. Source: CMS, State Operations Manual. deficiency on record in the last three years.
- Chain: DaVita.
CMS, Dialysis Facility - Listing by Facility. Released Jul 15, 2026. Updated quarterly.
CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 14, 2026. Updated monthly.
Has it been penalized?
- CMS doesn’t publish fines or other penalties for dialysis facilities.
- None of the deficiencies cited in the last three years came from an inspection that included a complaint investigation.
CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 14, 2026. Updated monthly.
What does it offer?
- Offers in-center hemodialysis.
- Doesn’t offer peritoneal dialysis, home hemodialysis training and a shift starting at 5 p.m. or later.
- 21 dialysis stations.
- CMS doesn’t publish staffing levels for dialysis facilities.
CMS, Dialysis Facility - Listing by Facility and Patient survey (ICH CAHPS) - Facility. Released Jul 15, 2026. Updated quarterly.
Who owns it?
- Part of the DaVita chain, as CMS lists it.
- CMS publishes no owners file for dialysis facilities, so no other owner is named.
CMS, Dialysis Facility - Listing by Facility. Released Jul 15, 2026. Updated quarterly.
How do patients fare?
- CMS rates it 5 of 5 stars (Jan 1, 2021 to Dec 31, 2024).
- Compared by CMS with what it expects for the facility’s patients: patient survival, as expected; hospital admissions, as expected; readmissions to hospital, as expected; blood transfusions, as expected; emergency department visits, as expected; emergency department visits within 30 days of a hospital stay, as expected; bloodstream infections, as expected; patients dialysing through a fistula, as expected; patients on a kidney transplant waitlist, as expected.
- CMS gives no CMS rates some kinds of place from 1 to 5 stars, more stars meaning better on CMS’s own measures for that kind: for a nursing home, its health inspections, staffing and quality measures. A rating is CMS’s summary of those measures; it doesn’t promise good care. Source: CMS, Care Compare and the Five-Star Quality Rating System.: “Too few completed survey responses to report.”
CMS, Dialysis Facility - Listing by Facility and Patient survey (ICH CAHPS) - Facility. Released Jul 15, 2026. Updated quarterly.
| Measure | Rating |
|---|---|
| Star ratingCMS’s star rating for dialysis facilities, 1 to 5 | 5 of 5 |
| Patient survey ratingCMS star rating from its survey of the facility’s in-center hemodialysis patients (ICH CAHPS), 1 to 5 | Not rated |
How does it compare nearby?
- Of the 13 dialysis facilities CMS lists in Hudson County, 11 have a star rating from CMS: 4 rated 5 of 5, 4 rated 4 of 5, 1 rated 3 of 5, 2 rated 2 of 5.
- CMS rates this one 5 of 5.
CMS, Dialysis Facility - Listing by Facility. Released Jul 15, 2026. Updated quarterly.
What the record doesn’t say
- CMS doesn’t publish fines or other penalties for dialysis facilities, so none are shown.
- Only complaints that led to a citation appear; complaints that didn’t aren’t published.
- QCOR says it has no dialysis inspection reports after February 19, 2026, while it moves to a new system: a later inspection is not shown yet.
- CMS doesn’t publish staffing levels for dialysis facilities.
- CMS publishes no owners file for dialysis facilities: the chain it lists is the only owner named.
Sources
-
Centers for Medicare & Medicaid Services, Dialysis Facility - Listing by Facility (23ew-n7w9).
Released Jul 15, 2026 and checked Oct 19, 2026. Updated quarterly. Public domain (U.S. Government work).
-
Centers for Medicare & Medicaid Services, Patient survey (ICH CAHPS) - Facility (59mq-zhts).
Released Jul 15, 2026 and checked Oct 19, 2026. Updated quarterly. Public domain (U.S. Government work).
-
Centers for Medicare & Medicaid Services, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies (ESRD_2567s_2018_to_2026YTD.xlsx).
Released Oct 14, 2026 and checked Oct 19, 2026. Updated monthly. Public domain (U.S. Government work).
If you believe something here is wrong, a correction starts with the agency whose record this copies: CMS. CMS’s own record is on Care Compare. If Hearth Record copied something wrongly, it will fix it and log the correction publicly, with its date: how corrections work.
This copy of the record was made on Oct 19, 2026.
From the facility
The public record above comes first. Anything the facility adds will appear here, below it, and say who wrote it.
Replies
None. Replies aren’t open yet. When they open, the facility will be able to answer any finding for free, and the reply will show beside that finding, unedited and dated.
Paid listing
None. Paid listings aren’t open yet. When they open, anything paid for will say “Paid by the facility”, and paying will never change a finding, a rating or the order of results.