Davita Mebane Dialysis
A dialysis facility in Mebane, North Carolina 27302
616 N First Street, Mebane, North Carolina 27302. (919) 563-1052.
Watch and the shortlist are kept with a free account, on every device. Your watch list. CMS’s own record is on Care Compare.
The short answer
Record last released by CMS on Oct 28, 2026.
- 3of 5 CMS’s star rating
- Not rated patient survey rating
- 5 deficiencies cited in the last three years
- 10 dialysis stations
Each figure’s source sits beside it, in its section below.
What these words mean3
- Star ratings
- CMS rates some kinds of place from 1 to 5 stars, more stars meaning better on CMS’s own measures for that kind: for a nursing home, its health inspections, staffing and quality measures. A rating is CMS’s summary of those measures; it doesn’t promise good care. Source: CMS, Care Compare and the Five-Star Quality Rating System.
- Inspection (survey)
- A visit by state inspectors, often unannounced, who check a place against the rules it must meet. For nursing homes and other places Medicare pays, CMS calls these visits surveys: a standard survey of a nursing home comes at least every 15 months, and a complaint survey whenever a complaint calls for one. Source: CMS; 42 CFR 488.308.
- Deficiency, citation, violation
- What inspectors write up when a place didn’t meet a rule: the rule, what they saw, and when. CMS calls it a deficiency; states may say citation or violation. It is the inspectors’ finding, not a court’s, and the place is usually asked for a plan to correct it. Source: CMS, statement of deficiencies (Form CMS-2567); each state’s licensing agency.
What did inspectors find?
The last inspection on record was on Mar 20, 2025: a standard inspection.
5 deficiencies cited in the last three years.
CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.
When those deficiencies happened
5 deficiencies in 1 month of the last 36. Last cited Mar 2025. Most serious: Standard-level. The last 3 years, to Oct 30, 2026.
| Jan | Feb | Mar | Apr | May | Jun | Jul | Aug | Sep | Oct | Nov | Dec | |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 2023 | Nov | Dec | ||||||||||
| 2024 | Jan | Feb | Mar | Apr | May | Jun | Jul | Aug | Sep | Oct | Nov | Dec |
| 2025 | Jan | Feb | Mar | Apr | May | Jun | Jul | Aug | Sep | Oct | Nov | Dec |
| 2026 | Jan | Feb | Mar | Apr | May | Jun | Jul | Aug | Sep | Oct |
Hover or focus a month to read it.
Hearth Record drew this from the dates and levels in the source’s own records.
Each deficiency, as cited
Rule titles as CMS’s inspectors cite them, set in sentence case.
CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.
Mar 20, 2025: standard inspection5 deficiencies
-
Ic - Clean, Disinfect Surfaces & Equipment/Written Protocols
The inspectors’ words, 421 words
“IC-DISINFECT SURFACES/EQUIP/WRITTEN PROTOCOL CFR(s): 494.30(a)(4)(ii) [The facility must demonstrate that it follows standard infection control precautions by implementing- (4) And maintaining procedures, in accordance with applicable State and local laws and accepted public health procedures, for the-] (ii) Cleaning and disinfection of contaminated surfaces, medical devices, and equipment. This Standard is not met as evidenced by: 38766 Based on a review of policy and procedures, observations, and staff interviews, the facility staff failed to disinfect infectious surfaces to minimize the spread of infection in 1 (one) of 19 hemodialysis stations observed on the treatment floor. Findings included: A review on 07/01/2021 of the facility policy titled “Infection Control for Dialysis Facilities” revised 04/2023 revealed “Purpose: To minimize the spread of infections or blood-borne pathogens in the dialysis facility environment... Disinfection... 13. At the end of each treatment, the dialysis station will be cleaned and disinfected. A ...i. The wall box, Drain, and Water supply lines are considered part of the dialysis delivery system...” Observation on 03/18/2025 between 1155 and 1255 on the treatment floor revealed a clear bin under the water box behind the hemodialysis machine in station #14. The observation indicated that the bin was roughly half full of a clear liquid. An interview on 03/18/2025 at 1220 with PCT #1 during the observation revealed that PCT #1 did know the bin was behind the hemodialysis machine. The interview revealed that a patient was at the station early in the morning, and the bin was not emptied or cleaned between patients. The interview revealed that it was a slow drip but could not tell where the leak was coming from. An interview on 03/18/2025 at 1235 The Biomedical Technician revealed that if a bin was placed under the water box, this indicated a leak at the station. The interview revealed that the staff were to notify Biomed of any leak on the treatment floor. The interview revealed that if Biomed had been notified of the leak, Biomed would have repaired the leak and emptied and disinfected the bin with 1:100 (one part bleach to 100 part water) bleach solution. A follow-up interview on 03/20/2025 at 0930 revealed the cleaning person had placed the bin under the water box behind the station. The interview revealed that the cleaning person saw the water leaking under the box and placed the bin under the water box to collect the water. The interview revealed that the bin was placed under the box on Friday or Saturday of last week. The interview confirmed the findings.”
-
Pe - Equipment Maintenance - Manufacturer’S Dfu
The inspectors’ words, 209 words
“PE-EQUIPMENT MAINTENANCE-MANUFACTURER’S DFU CFR(s): 494.60(b) The dialysis facility must implement and maintain a program to ensure that all equipment (including emergency equipment, dialysis machines and equipment, and the water treatment system) are maintained and operated in accordance with the manufacturer’s recommendations. This Standard is not met as evidenced by: 38766 Based on policy review, observations, and staff interviews, the facility staff failed to maintain oxygen (O2) cylinders per facility policy for five (5) of nine (9) O2 cylinders observed. Findings included: A review on 03/18/2025 of the “Safety Data Sheet” prepared on 09/06/2024 revealed “...Section 7: Handling and Storage ...Storage... Oxygen... Store and handle in accordance with all current regulations and standards. Grounding and bonding required...” An observation on 03/18/2025 between 1155 and 1255 during a tour of the treatment floor revealed that 9 oxygen cylinders were stored towards the back door near the lab area. Five of the nine cylinders were on the floor unsecured. An interview on 03/18/2025 at 1600 with the Manager of Clinical Services revealed that the oxygen cylinders were not supposed to be left unsecured on the floor. The interview revealed that the FA had ordered the holders, and the clinic was waiting for delivery. The interview confirmed that the policy was not followed.”
-
Pe-Fire Safety-Life Safety Code
The inspectors’ words, 279 words
“PE-FIRE SAFETY-LIFE SAFETY CODE CFR(s): 494.60(e)(1) (1) Except as provided in paragraph (d)(2) of this section, dialysis facilities that do not provide one or more exits to the outside at grade level from the patient treatment area level must comply with provisions of the Life Safety Code (NFPA 101 and its Tentative Interim Amendments TIA 12-1, TIA 12-2, TIA 12-3, and TIA 12-4) applicable to Ambulatory Health Care Occupancies, regardless of the number of patients served. This Standard is not met as evidenced by: 38766 Based on a review of the facility’s policy, Fire drill exercise documentation, and interview, the facility staff failed to ensure fire drill exercises were performed per policy. Findings included: A review on 03/20/2025 of the facility’s policy “Facility Emergency Management Plan (ICHD, Home) revised 10/2024 revealed “...Fire Safety Preparedness 1. FA, or designee, is responsible to: ...b. Conduct and review quarterly fire safety and evacuation training and drills for compliance, identify additional training and education needs...” A review on 03/20/2025 of the facility’s fire drill documentation from January 2024 to the present revealed that a fire drill was conducted on 12/10/2024. The review revealed no documentation of fire drills from January 1, 2024, to December 9, 2024 (the first three quarters of the calendar year). The review revealed that the facility failed to perform fire drill exercises as per policy. An interview with the FA on 03/20/2025 at 1620 revealed that the fire drill on December 10, 2024, was the only documentation found. The interview revealed that fire drills should be conducted every quarter. The interview revealed that the FA was on leave, and the facility failed to follow the policy in her absence.”
-
Assess B/P & Fluid Management Needs
The inspectors’ words, 537 words
“PA-ASSESS B/P, FLUID MANAGEMENT NEEDS CFR(s): 494.80(a)(2) The patient’s comprehensive assessment must include, but is not limited to, the following: Blood pressure, and fluid management needs. This Standard is not met as evidenced by: 38766 Based on a review of policy and procedures, medical records review, and staff interviews, the facility staff failed to perform and/or document patient monitoring every 30-45-minute during dialysis treatments for three (3) of eight (8) in-patient records reviewed (Patient #2, #3, and #6). Findings included: A review on 03/19/2025 of the facility policy titled, “Pre-Intra-Post Treatment Data Collection, Monitoring and Nursing Assessment,” revised 04/2024, revealed “... Intradialytic Data Collection/Assessment ...9. ...a. Vital signs and treatment monitoring ...iii. Non-nocturnal treatments are completed at least every thirty (30) minutes...” 1. An open medical record review on 03/19/2025 for Patient #2 revealed a 60-year-old male was admitted to the facility for ICHD treatments on 12/14/2022. A review of the treatment sheet dated 03/12/2025 revealed the treatment started at 0702 and ended at 1054 (229 minutes). The treatment flowsheet revealed no documented vital signs from 0901 through 1001 (60 minutes). A review of the treatment flowsheet on 03/17/2025 revealed the treatment started at 0736 and ended at 1118 (218 minutes). The treatment flowsheet revealed no documented vital signs from 1001 through 1118 (77 minutes). The review revealed the facility staff failed to monitor the patient every 30 minutes during the hemodialysis treatment per the facility policy. An interview on 03/20/2025 at 1330 with CCHT #2 revealed that the staff should take the patient’s vital signs and safety checks every 30 minutes. The CCHT confirmed that the policy required these checks to be conducted and documented every 30 minutes. 2. An open medical record review on 03/19/2025 for Patient #3 revealed a 46-year-old female was admitted to the facility for ICHD treatments on 12/12/2024. A review of the treatment sheet dated 03/4/2025 revealed the treatment started at 0720 and ended at 1104 (224 minutes). The treatment flowsheet revealed no documented vital signs from 0720 through 0816 (56 minutes). A review of the treatment flowsheet on 03/13/2025 revealed the treatment started at 0712 and ended at 1115 (243 minutes). The treatment flowsheet revealed no documented vital signs from 1000 through 1115 (75 minutes). The review revealed the facility staff failed to monitor the patient every 30 minutes during the hemodialysis treatment per the facility policy. An interview on 03/20/2025 at 1330 with CCHT #2 revealed that the staff should take the patient’s vital signs and safety checks every 30 minutes. The CCHT confirmed that the policy required these checks to be conducted and documented every 30 minutes. 3. An open medical record review on 03/19/2025 for Patient #6 revealed a 54-year-old female was admitted to the facility for ICHD treatments on 09/09/2024. A review of the treatment sheet dated 03/4/2025 revealed the treatment started at 0540 and ended at 0846 (186 minutes). The treatment flowsheet revealed no documented vital signs from 0603 through 0702 (59 minutes). An interview on 03/20/2025 at 1330 with CCHT #2 revealed that the staff should take the patient’s vital signs and safety checks every 30 minutes. The CCHT confirmed that the policy required these checks to be conducted and documented every 30 minutes.”
-
Achieve Adequate Clearance
The inspectors’ words, 719 words
“POC-ACHIEVE ADEQUATE CLEARANCE CFR(s): 494.90(a)(1) Achieve and sustain the prescribed dose of dialysis to meet a hemodialysis Kt/V of at least 1.2 and a peritoneal dialysis weekly Kt/V of at least 1.7 or meet an alternative equivalent professionally-accepted clinical practice standard for adequacy of dialysis. This Standard is not met as evidenced by: 38766 Based on policy review, medical record review, and staff interviews, the facility staff failed to follow the adequacy plan of care by failing to dialyze 2 of 10 (Patient #8 and #7) in-center hemodialysis patients at the prescribed BFR/DFR and/or treatment duration. Findings included: A review on 03/18/2025 of the facility policy titled “PRE-INTRA-POST TREATMENT DATA COLLECTION, MONITORING AND NURSING ASSESSMENT” revised April 2024 revealed “INTRADIALYTIC DATA COLLECTION/ASSESSMENT ... 9. ... b. At a minimum, obtain and document the following: ...iii. Blood and dialysate flows, arterial and venous pressures ... 10. If the dialysis prescription is not being met (including dialysis flow rate or change to/inability to obtain prescribed blood flow rate), the reason will be documented and the licensed nurse informed...” 1. An open medical record review on 03/18/2025 for Patient #8 revealed a 45-year-old female admitted to the facility for ICHD treatments on 05/21/2020. A review of the Physician orders revealed Patient #8’s Blood Flow Rate (BFR) was ordered at 400 and Dialysate Flow Rate (DFR) at 800. A review of the treatment flowsheet on 03/04/2025 revealed the treatment started at 0632 and ended at 1243 (315 minutes). A review of the Flowsheet revealed Patient #8’s BFR/DFR averages were 358/800, with no documentation for the decrease in the BFR. A review of the treatment flowsheet on 03/07/2025 revealed the treatment started at 0651 and ended at 1204 (313 minutes). A review of the Flowsheet revealed Patient #8’s BFR/DFR averages were 298/782, with no documentation for the decrease in the BFR/DFR. A review of the treatment flowsheet on 03/10/2025 revealed the treatment started at 0641 and ended at 1222 (341 minutes). A review of the Flowsheet revealed Patient #8’s BFR/DFR averages were 303/800, with no documentation for the decrease in the BFR. A review of the treatment flowsheet on 03/12/2025 revealed the treatment started at 0648 and ended at 1207 (315 minutes). A review of the Flowsheet revealed Patient #8’s BFR/DFR averages were 361/800, with no documentation for the decrease in the BFR. A review of the treatment flowsheet on 03/14/2025 revealed the treatment started at 0641 and ended at 1137 (296 minutes). A review of the Flowsheet revealed Patient #8’s BFR/DFR averages were 319/800, with no documentation for the decrease in the BFR. An interview on 03/20/2025 at 1330 with the FA revealed that the facility’s PCTs should notify the nursing staff any time they decrease the patient’s BFR/DFR, or the patients are unable to achieve their ordered BFR/DFR. The interview further revealed that the nursing staff should have assessed and documented the reason for the decrease or the patient’s inability to obtain the prescribed BFR/DFR. The interview confirmed the medical record findings that patient #8 was not treated at the prescribed BFR/DFR. 2. An open medical record review on 03/18/2025 for Patient #7 revealed a 45-year-old female admitted to the facility for ICHD treatments on 10/28/2024. A review of the Physician orders revealed Patient #7’s Blood Flow Rate (BFR) was ordered at 400 and Dialysate Flow Rate (DFR) at 500. A review of the treatment flowsheet on 03/03/2025 revealed the treatment started at 1311 and ended at 1621 (190 minutes). A review of the Flowsheet revealed Patient #7’s BFR/DFR averages were 371/467, with no documentation for the decrease in the BFR/DFR. A review of the treatment flowsheet on 02/10/2025 revealed the treatment started at 1331 and ended at 1622 (171 minutes). A review of the Flowsheet revealed Patient #8’s BFR/DFR averages were 300/500, with no documentation for the decrease in the BFR. An interview on 03/20/2025 at 1330 with the FA revealed that the facility’s PCTs should notify the nursing staff any time they decrease the patient’s BFR/DFR, or the patients are unable to achieve their ordered BFR/DFR. The interview further revealed that the nursing staff should have assessed and documented the reason for the decrease or the patient’s inability to obtain the prescribed BFR/DFR. The interview confirmed the medical record findings that patient #8 was not treated at the prescribed BFR/DFR.”
The one inspection in the last three years
| Date | Visit | What the record says |
|---|---|---|
| Mar 20, 2025 | Standard inspection | 5 deficiencies cited |
Is it certified?
- Medicare-certified dialysis facility, certified or last recertified on Sep 26, 2018.
- Run for profit.
- No For hospices, home health agencies, hospitals and dialysis facilities, CMS writes deficiencies at two levels. Standard is the usual one; condition-level is the more serious, when a problem is serious enough that the provider doesn’t meet a whole condition of taking part in Medicare. Source: CMS, State Operations Manual. deficiency on record in the last three years.
- Chain: DaVita.
CMS, Dialysis Facility - Listing by Facility. Released Jul 15, 2026. Updated quarterly.
CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.
Has it been penalized?
- CMS doesn’t publish fines or other penalties for dialysis facilities.
- None of the deficiencies cited in the last three years came from an inspection that included a complaint investigation.
CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.
What does it offer?
- Offers in-center hemodialysis.
- Doesn’t offer peritoneal dialysis, home hemodialysis training and a shift starting at 5 p.m. or later.
- 10 dialysis stations.
- CMS doesn’t publish staffing levels for dialysis facilities.
CMS, Dialysis Facility - Listing by Facility and Patient survey (ICH CAHPS) - Facility. Released Jul 15, 2026. Updated quarterly.
Who owns it?
- Part of the DaVita chain, as CMS lists it.
- CMS publishes no owners file for dialysis facilities, so no other owner is named.
CMS, Dialysis Facility - Listing by Facility. Released Jul 15, 2026. Updated quarterly.
How do patients fare?
- CMS rates it 3 of 5 stars (Jan 1, 2021 to Dec 31, 2024).
- Compared by CMS with what it expects for the facility’s patients: patient survival, as expected; hospital admissions, as expected; readmissions to hospital, as expected; emergency department visits, as expected; emergency department visits within 30 days of a hospital stay, as expected; bloodstream infections, as expected; patients dialysing through a fistula, as expected; patients put on a kidney transplant waitlist in their first year of dialysis, as expected; patients on a kidney transplant waitlist, as expected.
- CMS gives no CMS rates some kinds of place from 1 to 5 stars, more stars meaning better on CMS’s own measures for that kind: for a nursing home, its health inspections, staffing and quality measures. A rating is CMS’s summary of those measures; it doesn’t promise good care. Source: CMS, Care Compare and the Five-Star Quality Rating System.: “Too few completed survey responses to report.”
CMS, Dialysis Facility - Listing by Facility and Patient survey (ICH CAHPS) - Facility. Released Jul 15, 2026. Updated quarterly.
| Measure | Rating |
|---|---|
| Star ratingCMS’s star rating for dialysis facilities, 1 to 5 | 3 of 5 |
| Patient survey ratingCMS star rating from its survey of the facility’s in-center hemodialysis patients (ICH CAHPS), 1 to 5 | Not rated |
How does it compare nearby?
- Of the 7 dialysis facilities CMS lists in Alamance County, 7 have a star rating from CMS: 4 rated 3 of 5, 3 rated 2 of 5.
- CMS rates this one 3 of 5.
CMS, Dialysis Facility - Listing by Facility. Released Jul 15, 2026. Updated quarterly.
What the record doesn’t say
- CMS doesn’t publish fines or other penalties for dialysis facilities, so none are shown.
- Only complaints that led to a citation appear; complaints that didn’t aren’t published.
- QCOR says it has no dialysis inspection reports after February 19, 2026, while it moves to a new system: a later inspection is not shown yet.
- CMS doesn’t publish staffing levels for dialysis facilities.
- CMS publishes no owners file for dialysis facilities: the chain it lists is the only owner named.
Sources
-
Centers for Medicare & Medicaid Services, Dialysis Facility - Listing by Facility (23ew-n7w9).
Released Jul 15, 2026 and checked Oct 30, 2026. Updated quarterly. Public domain (U.S. Government work).
-
Centers for Medicare & Medicaid Services, Patient survey (ICH CAHPS) - Facility (59mq-zhts).
Released Jul 15, 2026 and checked Oct 30, 2026. Updated quarterly. Public domain (U.S. Government work).
-
Centers for Medicare & Medicaid Services, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies (ESRD_2567s_2018_to_2026YTD.xlsx).
Released Oct 28, 2026 and checked Oct 30, 2026. Updated monthly. Public domain (U.S. Government work).
If you believe something here is wrong, a correction starts with the agency whose record this copies: CMS. CMS’s own record is on Care Compare. If Hearth Record copied something wrongly, it will fix it and log the correction publicly, with its date: how corrections work.
This copy of the record was made on Oct 30, 2026.
From the facility
The public record above comes first. Anything the facility adds will appear here, below it, and say who wrote it.
Replies
None. Replies aren’t open yet. When they open, the facility will be able to answer any finding for free, and the reply will show beside that finding, unedited and dated.
Paid listing
None. Paid listings aren’t open yet. When they open, anything paid for will say “Paid by the facility”, and paying will never change a finding, a rating or the order of results.