Fmc - Joplin East
A dialysis facility in Joplin, Missouri 64804
522 West 32nd St Suite B, Joplin, Missouri 64804. (417) 782-4055.
Watch and the shortlist are kept with a free account, on every device. Your watch list. CMS’s own record is on Care Compare.
The short answer
Record last released by CMS on Oct 28, 2026.
- 2of 5 CMS’s star rating
- Not rated patient survey rating
- 5 deficiencies cited in the last three years
- 24 dialysis stations
Each figure’s source sits beside it, in its section below.
What these words mean3
- Star ratings
- CMS rates some kinds of place from 1 to 5 stars, more stars meaning better on CMS’s own measures for that kind: for a nursing home, its health inspections, staffing and quality measures. A rating is CMS’s summary of those measures; it doesn’t promise good care. Source: CMS, Care Compare and the Five-Star Quality Rating System.
- Inspection (survey)
- A visit by state inspectors, often unannounced, who check a place against the rules it must meet. For nursing homes and other places Medicare pays, CMS calls these visits surveys: a standard survey of a nursing home comes at least every 15 months, and a complaint survey whenever a complaint calls for one. Source: CMS; 42 CFR 488.308.
- Deficiency, citation, violation
- What inspectors write up when a place didn’t meet a rule: the rule, what they saw, and when. CMS calls it a deficiency; states may say citation or violation. It is the inspectors’ finding, not a court’s, and the place is usually asked for a plan to correct it. Source: CMS, statement of deficiencies (Form CMS-2567); each state’s licensing agency.
What did inspectors find?
The last inspection on record was on Mar 13, 2024: a standard inspection.
5 deficiencies cited in the last three years.
CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.
When those deficiencies happened
5 deficiencies in 1 month of the last 36. Last cited Mar 2024. Most serious: Standard-level. The last 3 years, to Oct 30, 2026.
| Jan | Feb | Mar | Apr | May | Jun | Jul | Aug | Sep | Oct | Nov | Dec | |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 2023 | Nov | Dec | ||||||||||
| 2024 | Jan | Feb | Mar | Apr | May | Jun | Jul | Aug | Sep | Oct | Nov | Dec |
| 2025 | Jan | Feb | Mar | Apr | May | Jun | Jul | Aug | Sep | Oct | Nov | Dec |
| 2026 | Jan | Feb | Mar | Apr | May | Jun | Jul | Aug | Sep | Oct |
Hover or focus a month to read it.
Hearth Record drew this from the dates and levels in the source’s own records.
Each deficiency, as cited
Rule titles as CMS’s inspectors cite them, set in sentence case.
CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.
Mar 13, 2024: standard inspection5 deficiencies
-
Carbon Adsorption - Monitoring, Testing Frequency
The inspectors’ words, 323 words
“CARBON ADSORP-MONITOR, TEST FREQUENCY CFR(s): 494.40(a) 6.2.5 Carbon adsorption: monitoring, testing freq Testing for free chlorine, chloramine, or total chlorine should be performed at the beginning of each treatment day prior to patients initiating treatment and again prior to the beginning of each patient shift. If there are no set patient shifts, testing should be performed approximately every 4 hours. Results of monitoring of free chlorine, chloramine, or total chlorine should be recorded in a log sheet. Testing for free chlorine, chloramine, or total chlorine can be accomplished using the N.N-diethyl-p-phenylene-diamine (DPD) based test kits or dip-and-read test strips. On-line monitors can be used to measure chloramine concentrations. Whichever test system is used, it must have sufficient sensitivity and specificity to resolve the maximum levels described in [AAMI] 4.1.1 (Table 1) [which is a maximum level of 0.1 mg/L]. Samples should be drawn when the system has been operating for at least 15 minutes. The analysis should be performed on-site, since chloramine levels will decrease if the sample is not assayed promptly. This Standard is not met as evidenced by: 17026 Based on observation and staff interview, the facility staff failed to properly check the chlorine level in the water. Elevated chlorine levels can cause hemolysis (destruction of red blood cells) for patients on dialysis treatment. This had the potential to effect all patients on dialysis treatment and cause in increase in complications. The facility census was 101. Findings included: 1. Observation on 3/11/24 at 1:01 PM showed Certified Clinical Hemodialysis Technician (CCHT) (C) checked the chlorine level in the water. CCHT (C) swished the test strip for 60 seconds, but did not wait 20 seconds after swishing the test strip to compare the test strip to the color chart. 2. During an interview on 3/11/24 at 1:03 PM, Registered Nurse (RN) (I) said staff should wait 20 seconds after swishing the test strip to compare the test strip to the color chart.”
-
Dialysate Proportioning - Monitor Ph/Conductivity
The inspectors’ words, 183 words
“DIALYS PROPORT-MONITOR PH/CONDUCTIVITY CFR(s): 494.40(a) 5.6 Dialysate proportioning: monitor pH/conductivity It is necessary for the operator to follow the manufacturer’s instructions regarding dialysate conductivity and to measure approximate pH with an independent method before starting the treatment of the next patient. This Standard is not met as evidenced by: 17026 Based on observations and staff interview, the facility staff failed to ensure three conductivity solutions were not expired. This had the potential to effect all patients on dialysis treatment and cause an increase in complications. The facility census was 101. Findings included: 1. Observation on 3/11/24 at 1:18 PM of the treatment area showed an approximately on-fourth full standard buffer solution 4.0 that expired 10/26/23. 2. Observation on 3/11/24 at 1:16 PM of the treatment area showed an approximately one-fourth full standard buffer solution 10.0 that expired 2/23/24. 3. Observation on 3/11/24 at 1:15 PM of the treatment area showed an approximately one-half full conductivity solution 14.0 that expired 2/29/24. 4. During an interview on 3/11/24 at 1:19 PM, the clinic manager said staff need to ensure the conductivity solutions are not expired.”
-
Appropriateness Of Dialysis Rx
The inspectors’ words, 255 words
“PA-APPROPRIATENESS OF DIALYSIS RX CFR(s): 494.80(a)(2) The patient’s comprehensive assessment must include, but is not limited to, the following: (2) Evaluation of the appropriateness of the dialysis prescription, This Standard is not met as evidenced by: 17026 Based on record review and staff interview, the facility staff failed to follow the physician order for the dialysate flow rate for three patients (Patient # 2, # 3, and # 4) out of 10 clinical records reviewed. This had the potential to effect all patients on dialysis treatment and cause an increase in complications. The facility census was 101. Findings included: 1. Review of the treatment flow sheet dated 3/11/24 for Patient # 2 showed the physician directed staff to set the dialysate flow rate at 600. The treatment flow sheet showed staff set the dialysate flow rate at 800 during the patient’s dialysis treatment. 2. Review of the treatment flow sheet dated 3/6/24 for Patient # 3 showed the physician directed staff to set the dialysate flow rate at 700. The treatment flow sheet showed staff set the dialysate flow rate at 800 during the patient’s dialysis treatment. 3. Review of the treatment flow sheet dated 3/11/24 for Patient # 4 showed the physician directed staff to set the dialysate flow rate at 700. The treatment flow sheet showed staff set the dialysate flow rate at 800 during the patient’s dialysis treatment. 4. During an interview on 3/12/24 at 2:15 PM, the clinic manager said staff should follow the physician order for the dialysate flow rate.”
-
Assess B/P & Fluid Management Needs
The inspectors’ words, 199 words
“PA-ASSESS B/P, FLUID MANAGEMENT NEEDS CFR(s): 494.80(a)(2) The patient’s comprehensive assessment must include, but is not limited to, the following: Blood pressure, and fluid management needs. This Standard is not met as evidenced by: 17026 Based on record review and staff interview, the facility staff failed to check the blood pressure every 30 minutes for two patients (Patient # 1 and # 2) out of 10 clinical records reviewed. This had the potential to effect all patients on dialysis treatment and cause an increase in blood pressure complications. The facility census was 101. Findings included: 1. Review of the treatment flow sheet dated 3/11/24 for Patient # 1 showed staff checked the patient’s blood pressure at 1:37 PM but did not check the blood pressure again until 3:00 PM during the patient’s dialysis treatment. 2. Review of the treatment flow sheet dated 3/11/24 for Patient # 2 showed staff checked the patient’s blood pressure at 2:24 PM but did not check the blood pressure again until 4:04 PM during the patient’s dialysis treatment. 3. During an interview on 3/12/24 at 2:15 PM, the clinic manager said staff should check the patient’s blood pressure every 30 minutes during dialysis treatment.”
-
Clia Labs/Meet Needs Of Patients
The inspectors’ words, 182 words
“LAB-CLIA LABS/MEET NEEDS OF PTS CFR(s): 494.130 The dialysis facility must provide or make available, laboratory services (other than tissue pathology and histocompatibility) to meet the needs of the ESRD patient. Any laboratory services, including tissue pathology and histocompatibility must be furnished by or obtained from, a facility that meets the requirements for laboratory services specified in part 493 of this chapter. This Standard is not met as evidenced by: 17026 Based on observations and staff interview, the facility staff failed to ensure six blood culture kits and 16 laboratory tubes were not expired. This had the potential to effect all patients on dialysis treatment and cause an increase in complications. The facility census was 101. Findings included: 1. Observation on 3/11/24 at 1:07 PM of the laboratory area showed six blood culture kits that expired 10/7/23. 2. Observation on 3/11/24 at 1:05 PM of the laboratory area showed 16 laboratory tubes that expired 11/30/23. 3. During an interview on 3/11/24 at 1:08 PM, the clinic manager said staff need to ensure the blood culture kits and laboratory tubes are not expired.”
The one inspection in the last three years
| Date | Visit | What the record says |
|---|---|---|
| Mar 13, 2024 | Standard inspection | 5 deficiencies cited |
Is it certified?
- Medicare-certified dialysis facility, certified or last recertified on Mar 29, 1996.
- Run for profit.
- No For hospices, home health agencies, hospitals and dialysis facilities, CMS writes deficiencies at two levels. Standard is the usual one; condition-level is the more serious, when a problem is serious enough that the provider doesn’t meet a whole condition of taking part in Medicare. Source: CMS, State Operations Manual. deficiency on record in the last three years.
- Chain: Fresenius Medical Care.
CMS, Dialysis Facility - Listing by Facility. Released Jul 15, 2026. Updated quarterly.
CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.
Has it been penalized?
- CMS doesn’t publish fines or other penalties for dialysis facilities.
- None of the deficiencies cited in the last three years came from an inspection that included a complaint investigation.
CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.
What does it offer?
- Offers in-center hemodialysis, peritoneal dialysis, home hemodialysis training and a shift starting at 5 p.m. or later.
- 24 dialysis stations.
- CMS doesn’t publish staffing levels for dialysis facilities.
CMS, Dialysis Facility - Listing by Facility and Patient survey (ICH CAHPS) - Facility. Released Jul 15, 2026. Updated quarterly.
Who owns it?
- Part of the Fresenius Medical Care chain, as CMS lists it.
- CMS publishes no owners file for dialysis facilities, so no other owner is named.
CMS, Dialysis Facility - Listing by Facility. Released Jul 15, 2026. Updated quarterly.
How do patients fare?
- CMS rates it 2 of 5 stars (Jan 1, 2021 to Dec 31, 2024).
- Compared by CMS with what it expects for the facility’s patients: patient survival, as expected; hospital admissions, as expected; readmissions to hospital, as expected; blood transfusions, as expected; emergency department visits, worse than expected; emergency department visits within 30 days of a hospital stay, as expected; bloodstream infections, as expected; patients dialysing through a fistula, as expected; patients put on a kidney transplant waitlist in their first year of dialysis, as expected; patients on a kidney transplant waitlist, as expected.
- CMS gives no CMS rates some kinds of place from 1 to 5 stars, more stars meaning better on CMS’s own measures for that kind: for a nursing home, its health inspections, staffing and quality measures. A rating is CMS’s summary of those measures; it doesn’t promise good care. Source: CMS, Care Compare and the Five-Star Quality Rating System.: “Too few completed survey responses to report.”
CMS, Dialysis Facility - Listing by Facility and Patient survey (ICH CAHPS) - Facility. Released Jul 15, 2026. Updated quarterly.
| Measure | Rating |
|---|---|
| Star ratingCMS’s star rating for dialysis facilities, 1 to 5 | 2 of 5 |
| Patient survey ratingCMS star rating from its survey of the facility’s in-center hemodialysis patients (ICH CAHPS), 1 to 5 | Not rated |
How does it compare nearby?
- Of the 4 dialysis facilities CMS lists in Jasper County, 4 have a star rating from CMS: 3 rated 3 of 5, 1 rated 2 of 5.
- CMS rates this one 2 of 5.
CMS, Dialysis Facility - Listing by Facility. Released Jul 15, 2026. Updated quarterly.
| Place | Star rating |
|---|---|
| Freeman Nephrology & Dialysis Center | 3 |
| Heartland Kidney Center | 3 |
| Freeman Health System Outpatient Dialysis Center | 3 |
What the record doesn’t say
- CMS doesn’t publish fines or other penalties for dialysis facilities, so none are shown.
- Only complaints that led to a citation appear; complaints that didn’t aren’t published.
- QCOR says it has no dialysis inspection reports after February 19, 2026, while it moves to a new system: a later inspection is not shown yet.
- CMS doesn’t publish staffing levels for dialysis facilities.
- CMS publishes no owners file for dialysis facilities: the chain it lists is the only owner named.
Sources
-
Centers for Medicare & Medicaid Services, Dialysis Facility - Listing by Facility (23ew-n7w9).
Released Jul 15, 2026 and checked Oct 30, 2026. Updated quarterly. Public domain (U.S. Government work).
-
Centers for Medicare & Medicaid Services, Patient survey (ICH CAHPS) - Facility (59mq-zhts).
Released Jul 15, 2026 and checked Oct 30, 2026. Updated quarterly. Public domain (U.S. Government work).
-
Centers for Medicare & Medicaid Services, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies (ESRD_2567s_2018_to_2026YTD.xlsx).
Released Oct 28, 2026 and checked Oct 30, 2026. Updated monthly. Public domain (U.S. Government work).
If you believe something here is wrong, a correction starts with the agency whose record this copies: CMS. CMS’s own record is on Care Compare. If Hearth Record copied something wrongly, it will fix it and log the correction publicly, with its date: how corrections work.
This copy of the record was made on Oct 30, 2026.
From the facility
The public record above comes first. Anything the facility adds will appear here, below it, and say who wrote it.
Replies
None. Replies aren’t open yet. When they open, the facility will be able to answer any finding for free, and the reply will show beside that finding, unedited and dated.
Paid listing
None. Paid listings aren’t open yet. When they open, anything paid for will say “Paid by the facility”, and paying will never change a finding, a rating or the order of results.