Hearth Record

Fkc - Lenexa

A dialysis facility in Lenexa, Kansas 66215

13201 W 98th St, Lenexa, Kansas 66215. (913) 492-4571.

CMS’s own record, on Care Compare

Watch and the shortlist are kept with a free account, on every device. Your watch list. CMS’s own record is on Care Compare.

The short answer

Record last released by CMS on Oct 14, 2026. We couldn’t read Centers for Medicare & Medicaid Services’ list since Nov 2, 2026: qcor.cms.gov now refuses our reader. This record is as of then.

The last 24 months 4 deficiencies in 1 month of the last 36. Last cited Apr 2025. Most serious: Standard-level. Every month

Each figure’s source sits beside it, in its section below.

What these words mean3
Star ratings
CMS rates some kinds of place from 1 to 5 stars, more stars meaning better on CMS’s own measures for that kind: for a nursing home, its health inspections, staffing and quality measures. A rating is CMS’s summary of those measures; it doesn’t promise good care. Source: CMS, Care Compare and the Five-Star Quality Rating System.
Inspection (survey)
A visit by state inspectors, often unannounced, who check a place against the rules it must meet. For nursing homes and other places Medicare pays, CMS calls these visits surveys: a standard survey of a nursing home comes at least every 15 months, and a complaint survey whenever a complaint calls for one. Source: CMS; 42 CFR 488.308.
Deficiency, citation, violation
What inspectors write up when a place didn’t meet a rule: the rule, what they saw, and when. CMS calls it a deficiency; states may say citation or violation. It is the inspectors’ finding, not a court’s, and the place is usually asked for a plan to correct it. Source: CMS, statement of deficiencies (Form CMS-2567); each state’s licensing agency.

What did inspectors find?

The last inspection on record was on Apr 10, 2025: a standard inspection.

4 deficiencies cited in the last three years.

Source:

CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 14, 2026. Updated monthly.

When those deficiencies happened

4 deficiencies in 1 month of the last 36. Last cited Apr 2025. Most serious: Standard-level. The last 3 years, to Oct 19, 2026.

4 deficiencies by month over the last 3 years. Each cell is one month.
JanFebMarAprMayJunJulAugSepOctNovDec
2023 NovDec
2024 JanFebMarAprMayJunJulAugSepOctNovDec
2025 JanFebMarAprMayJunJulAugSepOctNovDec
2026 JanFebMarAprMayJunJulAugSepOct

Hover or focus a month to read it.

No visit on record Visited, nothing cited A stronger orange is more serious, on its source’s own levels, read onto four bands: from the least serious it publishes to the most
Source:

Hearth Record drew this from the dates and levels in the source’s own records.

Each deficiency, as cited

Rule titles as CMS’s inspectors cite them, set in sentence case.

Source:

CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 14, 2026. Updated monthly.

Apr 10, 2025: standard inspection4 deficiencies
  • Ic - Wear Gloves/Hand Hygiene

    The inspectors’ words, 454 words

    “IC-WEAR GLOVES/HAND HYGIENE CFR(s): 494.30(a)(1) Wear disposable gloves when caring for the patient or touching the patient’s equipment at the dialysis station. Staff must remove gloves and wash hands between each patient or station. This Standard is not met as evidenced by: 50529 Based on observation, policy review, and interview, the facility failed to ensure patients washed their hands or performed hand hygiene after holding their dialysis (a medical treatment that removes waste products and excess fluid from the blood when the kidneys are unable to do so) access site (a surgically created entry point into the bloodstream) after treatment. This deficient practice provided a mode of contamination with the potential spread of infectious pathogens (organisms that may cause disease or infection) which could negatively impact the health and well-being of the 56 patients that received dialysis treatments at the facility. Findings Include: Review of a policy titled, “Hand Hygiene,” dated 11/06/23, showed, “...Patients should perform hand hygiene if able, prior to and after each dialysis treatment ...Gloves must be provided to patients when performing procedures which risk exposure to blood or body fluids, such as when self-cannulating or holding access sites post treatment to achieve hemostasis. To help ensure the prevention of cross contamination to their family member or other patients, hand hygiene must be performed...Gloves must be provided to patients when performing procedures which risk exposure to blood or body fluids ...To help ensure the prevention of cross contamination to their family members or other patients, hand hygiene must be performed.” An observation of the treatment floor on 04/08/25 at 11:25 AM, showed staff failed to offer hand sanitizer or remind a patient to wash their hands after holding access sites (site where needles were removed) after treatment. During an interview on 04/08/25 at 3:38 PM, Staff A, Clinical Manager (CM), stated that hand hygiene for patients after holding sites is an expectation, as well as staff following facility policy and procedure. Failure to follow policy could increase the risk of the possible spread of infectious pathogens. An observation of the treatment floor on 04/09/25 at 9:15 AM, showed Staff K, Patient Care Technician (PCT), assist the patient at station #4 with the removal of his “dirty” glove but failed to offer hand sanitizer or remind patient to wash hands before leaving the treatment floor. During an interview on 04/09/25 at 9:22 AM, Staff K, PCT, stated that he/she knew that offering hand sanitizer or reminding patients to wash hands after holding access sites and before leaving the treatment floor was in the facility policy but had forgotten. Staff K stated that failure to ensure hand hygiene of some form is performed puts patients, staff, and visitors at risk for cross contamination.”

    Rule V0113. Standard-level.

  • Ic - Handling Infectious Waste

    The inspectors’ words, 274 words

    “IC-HANDLING INFECTIOUS WASTE CFR(s): 494.30(a)(4)(i) [The facility must demonstrate that it follows standard infection control precautions by implementing-] (4) And maintaining procedures, in accordance with applicable State and local laws and accepted public health procedures, for the- (i) Handling, storage and disposal of potentially infectious waste; This Standard is not met as evidenced by: 50529 Based on observation, policy review, and interview, the facility failed to contain biohazardous medical waste (blood or other bodily fluids) prior to transporting waste across the dialysis (a medical procedure that removes waste products and excess fluid from the blood when the kidneys are unable to do so) treatment floor to nearest biohazardous waste bin. Failure to contain medical waste prior to transport has the potential to spread pathogens (organisms that may cause disease or infection), which could negatively impact the health and well-being of the 56 patients who receive treatments at the facility. Findings Include: Review of a policy titled, “General Cleanliness and Infection Control Guidelines,” dated 11/04/24, showed that blood or other potentially infectious materials are to be placed in a container that prevents leakage during collection, handling, and transport. Observation of the treatment floor on 04/09/25 between 9:29 AM and 10:11 AM showed staff carrying used dialyzers and bloodlines containing blood/blood products from the dialysis stations across the treatment floor to one of two centralized biohazardous containers without being contained in a manner to prevent spills/leaks. During an interview on 04/08/25 at 3:38 PM, Staff A, Clinical Manager, stated that staff carrying non-contained biohazardous waste across the treatment floor is against facility policy. Staff A confirmed this practice increases infection risk and endangers staff and patients.”

    Rule V0121. Standard-level.

  • Assess Current Health Status Inc Comorbids

    The inspectors’ words, 681 words

    “PA-ASSESS CURRENT HEALTH STATUS/COMORBIDS CFR(s): 494.80(a)(1) The patient’s comprehensive assessment must include, but is not limited to, the following: (1) Evaluation of current health status and medical condition, including co-morbid conditions. This Standard is not met as evidenced by: 50529 Based on policy review, record review and interview, the facility failed to monitor patient vital signs and/or machine parameters according to facility policy for 4 (Patient 1, 2, 3, and 6) of 4 sampled in-center patients. This deficient practice provided an opportunity for changes in vital signs to go unrecognized and unaddressed which could negatively impact the health and well-being of the 56 in-center patients who receive treatments at the facility. Findings Include: Review of a policy titled, “Patient Assessment and Monitoring,” dated 05/01/23, showed, “ ...Obtain blood pressure and pulse rate every 30 minutes or more as needed but not to exceed 45 minutes or per state regulations. Document machine parameters and safety checks every 30 or more often as needed but not to exceed 45 minutes or per state regulations...” Patient 1 Patient 1’s treatment sheet, dated 04/02/25, showed blood pressure and pulse were not documented for 76 minutes, from 2:40 PM until 3:36 PM. Documentation failed to show rationale why patient monitoring data was not completed. Patient 1’s treatment sheet, dated 03/24/25, showed blood pressure and pulse were not documented for 52 minutes, from 3:14 PM until 4:06 PM. Documentation failed to show rationale why patient monitoring data was not completed. Patient 1’s treatment sheet, dated 03/24/25, showed monitoring of machine parameters were not documented for 48 minutes, from 6:06 PM until 6:54 PM. Documentation failed to show rationale why patient monitoring data was not completed. Patient 2 Patient 2’s treatment sheet, dated 04/02/25, showed blood pressure and pulse were not documented for 61 minutes, from 4:32 PM until 5:33 PM. Documentation failed to show rationale why patient monitoring data was not completed. Patient 2’s treatment sheet, dated 04/02/25, showed blood pressure and pulse were not documented for 57 minutes, from 4:38 PM until 5:35 PM. Documentation failed to show rationale why patient monitoring data was not completed. Patient 3 Patient 3’s treatment sheet, dated 03/27/25, showed blood pressure and pulse were not documented 59 minutes, from 8:32 AM until 9:31 AM. Documentation failed to show rationale why patient monitoring data was not completed. Patient 3’s treatment sheet, dated 04/03/25, showed blood pressure and pulse were not documented for 51 minutes, from 6:11 AM until 7:02 AM. Documentation failed to show rationale why patient monitoring data was not completed. Patient 3’s treatment sheet, dated 04/03/25, showed monitoring of machine parameters were not documented for 49 minutes, from 8:33 AM until 9:22 AM. Documentation failed to show rationale why patient monitoring data was not completed. Patient 6 Patient 6’s treatment sheet, dated 03/29/25, showed blood pressure and pulse were not documented for 107 minutes, from 9:31 AM until 11:18 AM. Documentation failed to show rationale why patient monitoring data was not completed. Patient 6’s treatment sheet, dated 04/05/25, showed blood pressure and pulse were not documented for 48 minutes, from 8:30 AM until 9:18 AM. Documentation failed to show rationale why patient monitoring data was not completed. Patient 6’s treatment sheet, dated 04/05/25, showed blood pressure and pulse were not documented for 52 minutes, from 9:18 AM until 10:09 AM. Documentation failed to show rationale why patient monitoring data was not completed. Patient 6’s treatment sheet, dated 04/05/25, showed blood pressure and pulse were not documented for 42 minutes, from 10:36 AM until 11:18 AM. Documentation failed to show rationale why patient monitoring data was not completed. During an interview on 04/08/25 at 11:05 AM, Staff E, Registered Nurse (RN), stated that staff are expected to chart on and monitor patients every 30 minutes. Staff E could not speak to the risks, only that he/she knew it was the policy. During an interview on 04/08/25 at 3:38 PM, Staff A, Clinical Manager, (CM), stated that the expectation is for staff to monitor patients the entire time they’re on treatment, but treatment data is to be entered every 30 minutes.”

    Rule V0502. Standard-level.

  • Appropriateness Of Dialysis Rx

    The inspectors’ words, 838 words

    “PA-APPROPRIATENESS OF DIALYSIS RX CFR(s): 494.80(a)(2) The patient’s comprehensive assessment must include, but is not limited to, the following: (2) Evaluation of the appropriateness of the dialysis prescription, This Standard is not met as evidenced by: 50529 Based on policy review and record review, the facility failed to follow the individualized dialysis prescription as prescribed by the medical provider for 4 (Patient 1, 2, 3, and 6) of 4 sampled in-center patients. Failure to follow the medical providers’ dialysis prescription had the potential to negatively impact the effectiveness of the prescribed dialysis treatments for the 56 in-center patients who received dialysis treatments at the facility. Findings Include: Review of a policy titled, “Patient Assessment and Monitoring,” dated 05/01/23, showed, “ ...Check machine settings and measurements: Check prescribed blood flow is being achieved or reason is documented in medical record if unable to meet the prescribed blood flow. Check the dialysate flow rate setting is correct, and the prescribed flow rate is being delivered ...” Review of a policy titled, “Physician Order Documentation,” dated 07/03/23, showed “ ...It is the nurses’ responsibility to ensure that all treatments, medications, labs or any care provided to the patient have an accurately documented physician order ...Nurse practice acts requires nurses to carry out treatment care, medication administration, lab tests, procedures, and other treatments, based on physician orders ...” Patient 1 Patient 1’s treatment sheet, dated 03/24/25, showed a prescribed dialysate flow rate (DFR) of 700 milliliters per minute (mL/min) and prescribed blood flow rate (BFR) of 400 milliliters per minute (mL/min). The DFR was documented as 800 mL/min during the entire treatment. Documentation failed to show rationale why the prescribed DFR was not attained. Patient 1’s treatment sheet, dated 03/26/25, showed a prescribed DFR of 700 mL/min and prescribed BFR of 400 mL/min. The DFR was documented as 800 mL/min during the entire treatment. Documentation failed to show rationale why the prescribed DFR was not attained. Patient 1’s treatment sheet, dated 03/28/25, showed a prescribed DFR of 700 mL/min and prescribed BFR of 400 mL/min. The BFR was documented as 300 mL/min at 2:56 PM. Documentation failed to show rationale why the prescribed DFR and BFR was not attained. Patient 1’s treatment sheet, dated 03/31/25, showed a prescribed DFR of 700 mL/min and prescribed BFR of 400 mL/min. The BFR was documented as 300 mL/min and 350 mL/min during the entire treatment. Documentation failed to show rationale why the prescribed DFR was not attained. Patient 1’s treatment sheet, dated 04/04/25, showed a prescribed DFR of 700 mL/min and prescribed BFR of 400 mL/min. The BFR was documented as 250 mL/min and 350 mL/min from 4:16 PM until 4:31 PM. Documentation failed to show rationale why the prescribed DFR was not attained. Patient 2 Patient 2’s treatment sheet, dated 03/31/25, showed a prescribed DFR of 700 mL/min and prescribed BFR of 400 mL/min. The BFR was documented as 350 mL/min at 4:36 PM and was documented as 325 mL/min at 5:31 PM & 6:01 PM. Documentation failed to show rationale why the prescribed BFR was not attained. Patient 2’s treatment sheet, dated 04/04/25, showed a prescribed DFR of 700 mL/min and prescribed BFR of 400 mL/min. The BFR was documented as 300 mL/min from 5:35 PM until 6:31 PM. Documentation failed to show rationale why the prescribed BFR was not attained. Patient 3 Patient 3’s treatment sheet, dated 03/29/25, showed a prescribed DFR of 800 mL/min and prescribed BFR of 500 mL/min. The BFR was documented as 300 mL/min during the entire treatment. Documentation failed to show rationale why the prescribed BFR was not attained. Patient 3’s treatment sheet, dated 04/01/25, showed a prescribed DFR of 800 mL/min and prescribed BFR of 500 mL/min. The BFR was documented as 400 mL/min during the entire treatment. Documentation failed to show rationale why the prescribed BFR was not attained. Patient 3’s treatment sheet, dated 04/03/25, showed a prescribed DFR of 800 mL/min and prescribed BFR of 500 mL/min. The BFR was documented as 300 mL/min during the entire treatment. Documentation failed to show rationale why the prescribed BFR was not attained. Patient 6 Patient 6’s treatment sheet, dated 03/27/25, showed a prescribed DFR of Auto that based on treatment pressures and fluid removal that fluctuates from 600 mL/min to 800 mL/min and prescribed BFR of 400 mL/min. The BFR was documented as 450 mL/min at 8:01 AM and 415 mL/min for 119 minutes from 9:05 AM until 11:04 AM. Documentation failed to show rationale why the prescribed BFR was not attained. Patient 6’s treatment sheet, dated 04/01/25, showed a prescribed DFR of 800 mL/min and prescribed BFR of 500 mL/min. The BFR was documented as 350 mL/min during the entire treatment. Documentation failed to show rationale why the prescribed BFR was not attained. Patient 6’s treatment sheet, dated 04/05/25, showed a prescribed DFR of 800 mL/min and prescribed BFR of 500 mL/min. The BFR was documented as 350 mL/min during the entire treatment. Documentation failed to show rationale why the prescribed BFR was not attained.”

    Rule V0503. Standard-level.

The one inspection in the last three years
Inspections on record
DateVisitWhat the record says
Apr 10, 2025Standard inspection4 deficiencies cited

Is it certified?

  • Medicare-certified dialysis facility, certified or last recertified on May 31, 2018.
  • Run for profit.
  • No deficiency on record in the last three years.
  • Chain: Fresenius Medical Care.
Source:

CMS, Dialysis Facility - Listing by Facility. Released Jul 15, 2026. Updated quarterly.

CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 14, 2026. Updated monthly.

Has it been penalized?

  • CMS doesn’t publish fines or other penalties for dialysis facilities.
  • None of the deficiencies cited in the last three years came from an inspection that included a complaint investigation.
Source:

CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 14, 2026. Updated monthly.

What does it offer?

  • Offers in-center hemodialysis, peritoneal dialysis and home hemodialysis training.
  • Doesn’t offer a shift starting at 5 p.m. or later.
  • 13 dialysis stations.
  • CMS doesn’t publish staffing levels for dialysis facilities.
  • In CMS’s survey, patients rate its staff 5 of 5.
Source:

CMS, Dialysis Facility - Listing by Facility and Patient survey (ICH CAHPS) - Facility. Released Jul 15, 2026. Updated quarterly.

Who owns it?

  • Part of the Fresenius Medical Care chain, as CMS lists it.
  • CMS publishes no owners file for dialysis facilities, so no other owner is named.
Source:

CMS, Dialysis Facility - Listing by Facility. Released Jul 15, 2026. Updated quarterly.

How do patients fare?

  • CMS rates it 5 of 5 stars (Jan 1, 2021 to Dec 31, 2024).
  • Compared by CMS with what it expects for the facility’s patients: patient survival, better than expected; hospital admissions, as expected; readmissions to hospital, as expected; blood transfusions, as expected; emergency department visits, as expected; emergency department visits within 30 days of a hospital stay, as expected; bloodstream infections, as expected; patients dialysing through a fistula, as expected; patients put on a kidney transplant waitlist in their first year of dialysis, as expected; patients on a kidney transplant waitlist, as expected.
  • Patients rate it 4 of 5 in CMS’s survey of in-center hemodialysis patients (35 interviews, Oct 18, 2024 to Jul 11, 2025): 92% rated the facility 9 or 10 out of 10.
Source:

CMS, Dialysis Facility - Listing by Facility and Patient survey (ICH CAHPS) - Facility. Released Jul 15, 2026. Updated quarterly.

Ratings and measures, as published
MeasureRating
Star ratingCMS’s star rating for dialysis facilities, 1 to 55 of 5
Patient survey ratingCMS star rating from its survey of the facility’s in-center hemodialysis patients (ICH CAHPS), 1 to 54 of 5

How does it compare nearby?

  • Of the 12 dialysis facilities CMS lists in Johnson County, 11 have a star rating from CMS: 1 rated 5 of 5, 4 rated 4 of 5, 4 rated 3 of 5, 2 rated 2 of 5.
  • CMS rates this one 5 of 5.
Source:

CMS, Dialysis Facility - Listing by Facility. Released Jul 15, 2026. Updated quarterly.

What the record doesn’t say

  • CMS doesn’t publish fines or other penalties for dialysis facilities, so none are shown.
  • Only complaints that led to a citation appear; complaints that didn’t aren’t published.
  • QCOR says it has no dialysis inspection reports after February 19, 2026, while it moves to a new system: a later inspection is not shown yet.
  • CMS doesn’t publish staffing levels for dialysis facilities.
  • CMS publishes no owners file for dialysis facilities: the chain it lists is the only owner named.

Sources

If you believe something here is wrong, a correction starts with the agency whose record this copies: CMS. CMS’s own record is on Care Compare. If Hearth Record copied something wrongly, it will fix it and log the correction publicly, with its date: how corrections work.

Source:

This copy of the record was made on Oct 19, 2026.

From the facility

The public record above comes first. Anything the facility adds will appear here, below it, and say who wrote it.

Replies

None. Replies aren’t open yet. When they open, the facility will be able to answer any finding for free, and the reply will show beside that finding, unedited and dated.

Paid listing

None. Paid listings aren’t open yet. When they open, anything paid for will say “Paid by the facility”, and paying will never change a finding, a rating or the order of results.

How to read a record

Four things every record does, shown on an example record made up for this guide.

An example record, made up for this guide

An example nursing home

Made up for this guide: no real place is shown

Not fully inspected in over two years (CMS flag)

11 health citations at the latest inspection cycle

The state average is 14.3.

Source:

CMS, State and US Averages and Health Deficiencies. Released Oct 28, 2026. Updated monthly.

From the homeNone yet. Replies and paid listings aren’t open, and when they open they will sit here, below the record.

1 of 4

Every fact names its source.

Who published it, when, and how often it changes sit beside each fact, with a link to the agency’s own file.

Sign in

A free account keeps your watch list, shortlists, comparisons and saved searches on every device, and can email you when something you watch changes. Browsing never needs one.