Davita Gardner Dialysis
A dialysis facility in Gardner, Kansas 66030
328 E Main St, Gardner, Kansas 66030. (913) 884-8488.
Watch and the shortlist are kept with a free account, on every device. Your watch list. CMS’s own record is on Care Compare.
The short answer
Record last released by CMS on Oct 28, 2026. We couldn’t read Centers for Medicare & Medicaid Services’ list since Nov 2, 2026: qcor.cms.gov now refuses our reader. This record is as of then.
- 3of 5 CMS’s star rating
- Not rated patient survey rating
- 2 deficiencies cited in the last three years
- 16 dialysis stations
Each figure’s source sits beside it, in its section below.
What these words mean3
- Star ratings
- CMS rates some kinds of place from 1 to 5 stars, more stars meaning better on CMS’s own measures for that kind: for a nursing home, its health inspections, staffing and quality measures. A rating is CMS’s summary of those measures; it doesn’t promise good care. Source: CMS, Care Compare and the Five-Star Quality Rating System.
- Inspection (survey)
- A visit by state inspectors, often unannounced, who check a place against the rules it must meet. For nursing homes and other places Medicare pays, CMS calls these visits surveys: a standard survey of a nursing home comes at least every 15 months, and a complaint survey whenever a complaint calls for one. Source: CMS; 42 CFR 488.308.
- Deficiency, citation, violation
- What inspectors write up when a place didn’t meet a rule: the rule, what they saw, and when. CMS calls it a deficiency; states may say citation or violation. It is the inspectors’ finding, not a court’s, and the place is usually asked for a plan to correct it. Source: CMS, statement of deficiencies (Form CMS-2567); each state’s licensing agency.
What did inspectors find?
The last inspection on record was on Oct 24, 2024: a standard inspection.
2 deficiencies cited in the last three years.
CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.
When those deficiencies happened
2 deficiencies in 1 month of the last 36. Last cited Oct 2024. Most serious: Standard-level. The last 3 years, to Oct 30, 2026.
| Jan | Feb | Mar | Apr | May | Jun | Jul | Aug | Sep | Oct | Nov | Dec | |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 2023 | Nov | Dec | ||||||||||
| 2024 | Jan | Feb | Mar | Apr | May | Jun | Jul | Aug | Sep | Oct | Nov | Dec |
| 2025 | Jan | Feb | Mar | Apr | May | Jun | Jul | Aug | Sep | Oct | Nov | Dec |
| 2026 | Jan | Feb | Mar | Apr | May | Jun | Jul | Aug | Sep | Oct |
Hover or focus a month to read it.
Hearth Record drew this from the dates and levels in the source’s own records.
Each deficiency, as cited
Rule titles as CMS’s inspectors cite them, set in sentence case.
CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.
Oct 24, 2024: standard inspection2 deficiencies
-
Ic - Wear Gloves/Hand Hygiene
The inspectors’ words, 439 words
“IC-WEAR GLOVES/HAND HYGIENE CFR(s): 494.30(a)(1) Wear disposable gloves when caring for the patient or touching the patient’s equipment at the dialysis station. Staff must remove gloves and wash hands between each patient or station. This Standard is not met as evidenced by: 35949 Based on observation, interview, and facility policy review, the facility failed to ensure 2 (Certified Clinical Hemodialysis Technician [CCHT] 5 and CCHT 6) of 2 observed staff performed hand hygiene before they touched patient care equipment (dialysis machine). Failure to perform hand hygiene provided a mode of cross contamination with the potential spread of pathogens, which could negatively impact the health and well-being of the 39 patients who received dialysis treatments at the facility. Findings Include: A facility policy titled, “Infection Control for Dialysis Facilities,” revised 04/2023, indicated, “Hand Hygiene 1. All teammates, Physicians and Non-Physician (NPP) will perform hand hygiene a. upon entering and exiting the treatment area, b. prior to gloving and immediately after glove removal, c. after contamination with blood or other infectious material, d. after patient and dialysis delivery system contact, e. after interacting with wall boxes (i.e., plugging/unplugging acid/bicarb lines form [sic] dialysis machine, changing acid types, when exchanging a dialysis machine), f. between patients even if the contact is casual, g. before touching clean areas such as supplies, supply cart and chairside keyboard/mouse.” Observations of the dialysis treatment area on 10/22/24 revealed the following: At 9:17 AM, CCHT 5 was observed opening supply storage drawers while holding a pair of gloves in her left hand. CCHT 5 applied the held pair of gloves, entered Station 6, and touched the dialysis machine. At 9:18 AM, CCHT 5 was observed typing on a computer keyboard near Station 6. CCHT 5 obtained and applied a pair of gloves, entered Station 6, and touched the dialysis machine. At 9:21 AM, CCHT 6 was observed typing on a computer keyboard near Station 7. CCHT 6 obtained and applied a pair of gloves, entered Station 7, and touched the dialysis machine. During an interview on 10/22/24 at 9:26 AM, CCHT 5 stated she was sure she was trained and expected to perform hand hygiene before she touched patient care equipment. During an interview on 10/22/24 at 9:27 AM, CCHT 6 acknowledged she was trained and expected to perform hand hygiene before she touched patient care equipment. During an interview on 10/23/24 at 2:45 PM, the Medical Director confirmed staff should perform hand hygiene before they touched patient care equipment. During an interview on 10/24/24 at 8:30 AM, the Facility Administrator confirmed staff were trained and expected to perform hand hygiene before they touched patient care equipment.”
-
Appropriateness Of Dialysis Rx
The inspectors’ words, 992 words
“PA-APPROPRIATENESS OF DIALYSIS RX CFR(s): 494.80(a)(2) The patient’s comprehensive assessment must include, but is not limited to, the following: (2) Evaluation of the appropriateness of the dialysis prescription, This Standard is not met as evidenced by: 35949 Based on interview, record review, and facility policy review, the facility failed to follow the individualized dialysis prescription as prescribed by the medical provider for 2 (Patient 3 and Patient 4) of 5 sampled patients. Failure to follow the medical providers’ dialysis prescription had the potential to negatively impact the effectiveness of the prescribed dialysis treatments for the 39 patients who received dialysis treatments at the facility. Findings Include: A facility policy titled, “Anticoagulation,” revised 09/2024, revealed “Use of Heparin: 3. Heparin is administered per physician/Non-Physician Practitioner (NPP) order.” 1. Review of Patient 3’s “Treatment Details Report,” dated 10/01/24, revealed a prescribed hourly infusion of heparin to be stopped 60 minutes before the end of the treatment. The “Intradialytic Vitals Stat Line” revealed a heparin pump stop time of 9:02 AM, 42 minutes before the treatment termination at 9:44 AM. Review of Patient 3’s “Treatment Details Report,” dated 10/03/24, revealed a prescribed hourly infusion of heparin to be stopped 60 minutes before the end of the treatment. The “Intradialytic Vitals Stat Line” revealed a heparin pump stop time of 9:02 AM, 45 minutes before the treatment termination at 9:47 AM. Review of Patient 3’s “Treatment Details Report,” dated 10/05/24, revealed a prescribed hourly infusion of heparin to be stopped 60 minutes before the end of the treatment. The “Intradialytic Vitals Stat Line” revealed a heparin pump stop time of 9:03 AM, 44 minutes before the treatment termination at 9:47 AM. Review of Patient 3’s “Treatment Details Report,” dated 10/08/24, revealed a prescribed hourly infusion of heparin to be stopped 60 minutes before the end of the treatment. The “Intradialytic Vitals Stat Line” revealed a heparin pump stop time of 9:47 AM, three minutes after the treatment termination at 9:44 AM. Review of Patient 3’s “Treatment Details Report,” dated 10/10/24, revealed a prescribed hourly infusion of heparin to be stopped 60 minutes before the end of the treatment. The “Intradialytic Vitals Stat Line” revealed a heparin pump stop time of 9:02 AM, 44 minutes before the treatment termination at 9:46 AM. Review of Patient 3’s “Treatment Details Report,” dated 10/12/24, revealed a prescribed hourly infusion of heparin to be stopped 60 minutes before the end of the treatment. The “Intradialytic Vitals Stat Line” revealed a heparin pump stop time of 9:03 AM, 43 minutes before the treatment termination at 9:46 AM. Review of Patient 3’s “Treatment Details Report,” dated 10/15/24, revealed a prescribed hourly infusion of heparin to be stopped 60 minutes before the end of the treatment. The “Intradialytic Vitals Stat Line” revealed a heparin pump stop time of 9:03 AM, 48 minutes before the treatment termination at 9:51 AM. Review of Patient 3’s “Treatment Details Report,” dated 10/17/24, revealed a prescribed hourly infusion of heparin to be stopped 60 minutes before the end of the treatment. The “Intradialytic Vitals Stat Line” revealed a heparin pump stop time of 9:03 AM, 41 minutes before the treatment termination at 9:44 AM. 2. Review of Patient 4’s “Treatment Details Report,” dated 10/02/24, revealed a prescribed hourly infusion of heparin to be stopped 60 minutes before the end of the treatment. The “Intradialytic Vitals Stat Line” revealed a heparin pump stop time of 12:31 PM, 38 minutes before the treatment termination at 1:09 PM. Review of Patient 4’s “Treatment Details Report,” dated 10/07/24, revealed a prescribed hourly infusion of heparin to be stopped 60 minutes before the end of the treatment. The “Intradialytic Vitals Stat Line” revealed a heparin pump stop time of 12:31 PM, 34 minutes before the treatment termination at 1:05 PM. Review of Patient 4’s “Treatment Details Report,” dated 10/09/24, revealed a prescribed hourly infusion of heparin to be stopped 60 minutes before the end of the treatment. The “Intradialytic Vitals Stat Line” revealed a heparin pump stop time of 12:31 PM, 51 minutes before the treatment termination at 1:22 PM. Review of Patient 4’s “Treatment Details Report,” dated 10/11/24, revealed a prescribed hourly infusion of heparin to be stopped 60 minutes before the end of the treatment. The “Intradialytic Vitals Stat Line” revealed a heparin pump stop time of 12:31 PM, 40 minutes before the treatment termination at 1:11 PM. Review of Patient 4’s “Treatment Details Report,” dated 10/14/24, revealed a prescribed hourly infusion of heparin to be stopped 60 minutes before the end of the treatment. The “Intradialytic Vitals Stat Line” revealed a heparin pump stop time of 1:24 PM, the same time as the treatment termination at 1:24 PM. Review of Patient 4’s “Treatment Details Report,” dated 10/16/24, revealed a prescribed hourly infusion of heparin to be stopped 60 minutes before the end of the treatment. The “Intradialytic Vitals Stat Line” revealed a heparin pump stop time of 12:31 PM, 35 minutes before the treatment termination at 1:06 PM. Review of Patient 4’s “Treatment Details Report,” dated 10/18/24, revealed a prescribed hourly infusion of heparin to be stopped 60 minutes before the end of the treatment. The “Intradialytic Vitals Stat Line” revealed a heparin pump stop time of 12:31 PM, 39 minutes before the treatment termination at 1:10 PM. Review of Patient 4’s “Treatment Details Report,” dated 10/21/24, revealed a prescribed hourly infusion of heparin to be stopped 60 minutes before the end of the treatment. The “Intradialytic Vitals Stat Line” revealed a heparin pump stop time of 12:31 PM, 35 minutes before the treatment termination at 1:06 PM. During an interview on 10/23/24 at 2:45 PM, the Medical Director confirmed staff were expected to follow physicians’ orders. During an interview on 10/23/24 at 5:06 PM, Registered Nurse (RN) 4 confirmed staff were trained and expected to follow physicians’ orders. During an interview on 10/24/24 at 8:30 AM, the Facility Administrator confirmed the staff were trained and expected to follow physicians’ orders.”
The one inspection in the last three years
| Date | Visit | What the record says |
|---|---|---|
| Oct 24, 2024 | Standard inspection | 2 deficiencies cited |
Is it certified?
- Medicare-certified dialysis facility, certified or last recertified on Oct 23, 2015.
- Run for profit.
- No For hospices, home health agencies, hospitals and dialysis facilities, CMS writes deficiencies at two levels. Standard is the usual one; condition-level is the more serious, when a problem is serious enough that the provider doesn’t meet a whole condition of taking part in Medicare. Source: CMS, State Operations Manual. deficiency on record in the last three years.
- Chain: DaVita.
CMS, Dialysis Facility - Listing by Facility. Released Jul 15, 2026. Updated quarterly.
CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.
Has it been penalized?
- CMS doesn’t publish fines or other penalties for dialysis facilities.
- None of the deficiencies cited in the last three years came from an inspection that included a complaint investigation.
CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.
What does it offer?
- Offers in-center hemodialysis.
- Doesn’t offer peritoneal dialysis, home hemodialysis training and a shift starting at 5 p.m. or later.
- 16 dialysis stations.
- CMS doesn’t publish staffing levels for dialysis facilities.
CMS, Dialysis Facility - Listing by Facility and Patient survey (ICH CAHPS) - Facility. Released Jul 15, 2026. Updated quarterly.
Who owns it?
- Part of the DaVita chain, as CMS lists it.
- CMS publishes no owners file for dialysis facilities, so no other owner is named.
CMS, Dialysis Facility - Listing by Facility. Released Jul 15, 2026. Updated quarterly.
How do patients fare?
- CMS rates it 3 of 5 stars (Jan 1, 2021 to Dec 31, 2024).
- Compared by CMS with what it expects for the facility’s patients: patient survival, as expected; hospital admissions, as expected; readmissions to hospital, as expected; blood transfusions, as expected; emergency department visits, as expected; emergency department visits within 30 days of a hospital stay, as expected; bloodstream infections, as expected; patients dialysing through a fistula, as expected; patients on a kidney transplant waitlist, as expected.
- CMS gives no CMS rates some kinds of place from 1 to 5 stars, more stars meaning better on CMS’s own measures for that kind: for a nursing home, its health inspections, staffing and quality measures. A rating is CMS’s summary of those measures; it doesn’t promise good care. Source: CMS, Care Compare and the Five-Star Quality Rating System.: “Too few completed survey responses to report.”
CMS, Dialysis Facility - Listing by Facility and Patient survey (ICH CAHPS) - Facility. Released Jul 15, 2026. Updated quarterly.
| Measure | Rating |
|---|---|
| Star ratingCMS’s star rating for dialysis facilities, 1 to 5 | 3 of 5 |
| Patient survey ratingCMS star rating from its survey of the facility’s in-center hemodialysis patients (ICH CAHPS), 1 to 5 | Not rated |
How does it compare nearby?
- Of the 12 dialysis facilities CMS lists in Johnson County, 11 have a star rating from CMS: 1 rated 5 of 5, 4 rated 4 of 5, 4 rated 3 of 5, 2 rated 2 of 5.
- CMS rates this one 3 of 5.
CMS, Dialysis Facility - Listing by Facility. Released Jul 15, 2026. Updated quarterly.
What the record doesn’t say
- CMS doesn’t publish fines or other penalties for dialysis facilities, so none are shown.
- Only complaints that led to a citation appear; complaints that didn’t aren’t published.
- QCOR says it has no dialysis inspection reports after February 19, 2026, while it moves to a new system: a later inspection is not shown yet.
- CMS doesn’t publish staffing levels for dialysis facilities.
- CMS publishes no owners file for dialysis facilities: the chain it lists is the only owner named.
Sources
-
Centers for Medicare & Medicaid Services, Dialysis Facility - Listing by Facility (23ew-n7w9).
Released Jul 15, 2026 and checked Oct 30, 2026. Updated quarterly. Public domain (U.S. Government work).
-
Centers for Medicare & Medicaid Services, Patient survey (ICH CAHPS) - Facility (59mq-zhts).
Released Jul 15, 2026 and checked Oct 30, 2026. Updated quarterly. Public domain (U.S. Government work).
-
Centers for Medicare & Medicaid Services, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies (ESRD_2567s_2018_to_2026YTD.xlsx).
Released Oct 28, 2026 and checked Oct 30, 2026. Updated monthly. Public domain (U.S. Government work).
If you believe something here is wrong, a correction starts with the agency whose record this copies: CMS. CMS’s own record is on Care Compare. If Hearth Record copied something wrongly, it will fix it and log the correction publicly, with its date: how corrections work.
This copy of the record was made on Oct 30, 2026.
From the facility
The public record above comes first. Anything the facility adds will appear here, below it, and say who wrote it.
Replies
None. Replies aren’t open yet. When they open, the facility will be able to answer any finding for free, and the reply will show beside that finding, unedited and dated.
Paid listing
None. Paid listings aren’t open yet. When they open, anything paid for will say “Paid by the facility”, and paying will never change a finding, a rating or the order of results.