Valparaiso Dialysis
A dialysis facility in Valparaiso, Indiana 46383
2711 Leonard Drive, Suite 100, Valparaiso, Indiana 46383. (219) 462-1233.
Watch and the shortlist are kept with a free account, on every device. Your watch list. CMS’s own record is on Care Compare.
The short answer
Record last released by CMS on Oct 28, 2026. We couldn’t read Centers for Medicare & Medicaid Services’ list since Nov 2, 2026: qcor.cms.gov now refuses our reader. This record is as of then.
- 3of 5 CMS’s star rating
- Not rated patient survey rating
- 7 deficiencies cited in the last three years
- 16 dialysis stations
Each figure’s source sits beside it, in its section below.
What these words mean3
- Star ratings
- CMS rates some kinds of place from 1 to 5 stars, more stars meaning better on CMS’s own measures for that kind: for a nursing home, its health inspections, staffing and quality measures. A rating is CMS’s summary of those measures; it doesn’t promise good care. Source: CMS, Care Compare and the Five-Star Quality Rating System.
- Inspection (survey)
- A visit by state inspectors, often unannounced, who check a place against the rules it must meet. For nursing homes and other places Medicare pays, CMS calls these visits surveys: a standard survey of a nursing home comes at least every 15 months, and a complaint survey whenever a complaint calls for one. Source: CMS; 42 CFR 488.308.
- Deficiency, citation, violation
- What inspectors write up when a place didn’t meet a rule: the rule, what they saw, and when. CMS calls it a deficiency; states may say citation or violation. It is the inspectors’ finding, not a court’s, and the place is usually asked for a plan to correct it. Source: CMS, statement of deficiencies (Form CMS-2567); each state’s licensing agency.
What did inspectors find?
The last inspection on record was on Feb 26, 2025: a standard inspection.
7 deficiencies cited in the last three years.
CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.
When those deficiencies happened
7 deficiencies in 1 month of the last 36. Last cited Feb 2025. Most serious: Standard-level. The last 3 years, to Oct 30, 2026.
| Jan | Feb | Mar | Apr | May | Jun | Jul | Aug | Sep | Oct | Nov | Dec | |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 2023 | Nov | Dec | ||||||||||
| 2024 | Jan | Feb | Mar | Apr | May | Jun | Jul | Aug | Sep | Oct | Nov | Dec |
| 2025 | Jan | Feb | Mar | Apr | May | Jun | Jul | Aug | Sep | Oct | Nov | Dec |
| 2026 | Jan | Feb | Mar | Apr | May | Jun | Jul | Aug | Sep | Oct |
Hover or focus a month to read it.
Hearth Record drew this from the dates and levels in the source’s own records.
Each deficiency, as cited
Rule titles as CMS’s inspectors cite them, set in sentence case.
CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.
Feb 26, 2025: standard inspection7 deficiencies
-
Local, State, Tribal Collaboration Process
The inspectors’ words, 331 words
“Local, State, Tribal Collaboration Process CFR(s): §403.748(a)(4), §416.54(a)(4), §418.113(a)(4), §441.184(a)(4), §460.84(a)(4), §482.15(a)(4), §483.73(a)(4), §483.475(a)(4), §484.102(a)(4), §485.68(a)(4), §485.542(a)(4), §485.625(a)(4), §485.727(a)(5), §485.920(a)(4), §486.360(a)(4), §491.12(a)(4), §494.62(a)(4) [(a) Emergency Plan. The [facility] must develop and maintain an emergency preparedness plan that must be reviewed, and updated at least every 2 years [annually for LTC facilities]. The plan must do the following:] (4) Include a process for cooperation and collaboration with local, tribal, regional, State, and Federal emergency preparedness officials’ efforts to maintain an integrated response during a disaster or emergency situation. * * [For ESRD facilities only at §494.62(a)(4)]: (4) Include a process for cooperation and collaboration with local, tribal, regional, State, and Federal emergency preparedness officials’ efforts to maintain an integrated response during a disaster or emergency situation. The dialysis facility must contact the local emergency preparedness agency at least annually to confirm that the agency is aware of the dialysis facility’s needs in the event of an emergency. This Standard is not met as evidenced by: 47022 Based on record review and interview, the dialysis facility failed to ensure collaboration with local/regional emergency management officials was documented annually to confirm officials were aware of the dialysis facility needs in an emergency in 1 of 1 agency. Findings include: A revised policy, dated 05/20/2022, titled, “Emergency Preparedness Overview,” indicated the Clinic Manager would contact the local emergency management agency annually to ensure that the agency was aware of the dialysis facility’s needs in the event of an emergency. The policy indicated a record of the contact would be kept in the emergency preparedness manual. Dialysis facility letters, dated 12/19/2018 and 01/09/2019, to an Emergency Management Disaster Services, indicated the local emergency management was to be notified annually to ensure the Emergency Management was aware of the dialysis facility needs in the event of an emergency. During an interview on 02/24/2025, beginning at 1:00 PM, the Clinical Manager indicated the dialysis facility did not have documentation their local emergency management officials were contacted since 2019.”
-
Ic - Sanitary Environment
The inspectors’ words, 586 words
“IC-SANITARY ENVIRONMENT CFR(s): 494.30 The dialysis facility must provide and monitor a sanitary environment to minimize the transmission of infectious agents within and between the unit and any adjacent hospital or other public areas. This Standard is not met as evidenced by: 51199 Based on observation, record review, and interview, the dialysis facility failed to ensure a sanitary environment to minimize the transmission of infectious agents in 2 of 3 observations of prepared bleach during 1 of 3 observations of the incenter and failed to ensure all staff [PCT 4] minimized the transmission of infectious agents when cleaning nondisposable equipment between clean and dirty areas in 1 of 2 observations of staff preparing an HD [a process to filter the blood of a patients whose kidneys do not work normally] station. Findings include: 1. A revised policy, dated 06/20/2024, titled “G45 Cleaning & Disinfection of Equipment, Supplies & Treatment Area”, indicated that bleach solutions must be covered with a lid to prevent contamination. 2. A policy, dated 06/20/2024, titled, “Checking Conductivity and Ph of Dialysate - Using Phoenix Meter,” indicated after the dialysate sample was collected and discarded in dirty sink or prime bucket the external meter would be wiped with 1:100 prepared bleach solution if the meter was to be stored in a clean designated area. 3. A revised policy, dated 11/29/2022, titled, “Infection Control,” indicated each center would maintain a clean and dirty work area, clean items such as medications and gloves are kept in the designated clean areas. The policy indicated reusable supplies would not be shared between patients without being disinfected between each use per the appropriate procedure. 4. During an observation on 02/21/2025, beginning at 10:16AM, a container on the treatment floor, identified as a bleach 1:100 solution, was observed near station 14; the container was uncovered and remained uncovered at the conclusion of observation, at 11:25AM. 5. During an interview on 02/25/2025, beginning at 10:10AM, The Clinical Manager indicated that bleach solutions on the treatment floor were to remain covered when not in use. 47022 6. During an observation, on 02/21/2025 beginning at 9:55 AM, PCT 4 retrieved the Phoenix meter from the top of a cabinet, where other supplies were stored, and included packaged saline, packaged tubing, packaged dialyzers, a container labeled as clean ancillary supplies, and gloves. PCT 4 then entered station #3 where Patient #9 was present. PCT 4 completed a conductivity test, with the Phoenix meter, and returned the Phoenix meter to the top of the cabinet, with the other supplies, without decontaiminating / cleaning the meter. 7. During an interview on 02/21/2025, beginning at 10:55 AM, PCT 4 indicated the Phoenix meter did not need to be cleaned prior to returning to the clean cabinet because she did not put the Phoenix meter on the HD machine nor place near computer at the station. PCT 4 indicated the Phoenix meter would be cleaned in the morning and at the end of the day. 8. During an observation on 02/21/2025, beginning at 9:55 AM, a 1:100 bleach solution, with submerged clamps, was observed next to the dirty sink in the pod with Stations #1 to #8; the lid was off, and staff was not present at the dirty sink area. At 10:05 AM, PCT 5 went to the dirty sink area, placed a clamp in the 1:100 bleach solution and covered the bleach solution container. 9. During an interview on 02/21/2025, beginning at 10:55 AM, PCT 4 indicated bleach solutions should be covered with a lid.”
-
Ic - Wear Gloves/Hand Hygiene
The inspectors’ words, 330 words
“IC-WEAR GLOVES/HAND HYGIENE CFR(s): 494.30(a)(1) Wear disposable gloves when caring for the patient or touching the patient’s equipment at the dialysis station. Staff must remove gloves and wash hands between each patient or station. This Standard is not met as evidenced by: 51199 Based on observation, record review, and interview, the facility failed to ensure PCT 5 performed hand hygiene when they performed central venous catheter [CVC] (large catheter into vein) care in 1 of 2 CVC discontinuations observed (PCT 5 with Patient #14) and the facility failed to ensure that PCT 6 performed hand hygiene and a change of gloves in 1 of 3 observation of CVC exit site care (PCT 6 with Patient #6). Findings include: 1. A revised policy, dated 11/29/2022, titled “G40 Infection Control”, indicated that hands should always be washed after gloves are removed. 2. A revised policy, dated 11/29/2022, titled, “Infection Control,” indicated hands are washed after gloves are removed, between patient contacts, and after touching contaminated items. The policy indicated that all blood line and CVC connections would be handled using proper aseptic technique 3. During an observation on 02/21/2025, beginning at 10:09AM, PCT 6 and PCT 3, at station #10, changed the CVC dressing on Patient #6. During the observation, after removing the old dressing, PCT 6 failed to perform hand hygiene and don new gloves prior to cleansing area and applying new dressing. 4. During an interview on 02/21/2025, beginning at 10:15AM, PCT 3 indicated that hand hygiene and glove change should occur after discarding old dressing. 47022 5. During an observation on 02/24/2025, beginning at 2:30 PM, PCT 5 was at station #8, with Patient #14. PCT 5 was wearing gloves and touched the buttons on the hemodialysis machine [HD] (a process to filter the blood of a patient whose kidneys do not work normally), PCT 5 then returned to Patient’s CVC and began to clean the hubs [HD access] of the CVC without changing gloves or performing hand hygiene.”
-
Carbon Adsorption - Monitoring, Testing Frequency
The inspectors’ words, 380 words
“CARBON ADSORP-MONITOR, TEST FREQUENCY CFR(s): 494.40(a) 6.2.5 Carbon adsorption: monitoring, testing freq Testing for free chlorine, chloramine, or total chlorine should be performed at the beginning of each treatment day prior to patients initiating treatment and again prior to the beginning of each patient shift. If there are no set patient shifts, testing should be performed approximately every 4 hours. Results of monitoring of free chlorine, chloramine, or total chlorine should be recorded in a log sheet. Testing for free chlorine, chloramine, or total chlorine can be accomplished using the N.N-diethyl-p-phenylene-diamine (DPD) based test kits or dip-and-read test strips. On-line monitors can be used to measure chloramine concentrations. Whichever test system is used, it must have sufficient sensitivity and specificity to resolve the maximum levels described in [AAMI] 4.1.1 (Table 1) [which is a maximum level of 0.1 mg/L]. Samples should be drawn when the system has been operating for at least 15 minutes. The analysis should be performed on-site, since chloramine levels will decrease if the sample is not assayed promptly. This Standard is not met as evidenced by: 51199 Based on interview and record review, the facility failed to evidence all staff were tested and passed a color-blindness test to ensure their ability to accurately interpret colors on test strips in 1 of 3 PCT employee files reviewed [PCT 3]. Findings include: 1. A policy, dated 04/24/2024, titled “IC30 Color Blindness Testing,” indicated that upon hire, all staff responsible for interpreting results of any testing strips must have documentation of completing and passing the Ishihara Color Blind Test with results maintained in their training record. Additionally, it indicated that the Clinic Manager should administer the test and document the results on the testing form. 2. During a personnel record review on 02/25/2025, the dialysis facility presented a blank color-blindness test with no results for PCT 3, dated 07/17/2023. 3. During a review of daily water logs and chlorine logs on 02/25/2025, it was noted that PCT 3 performed water testing, that included reading test strips, on multiple days in December 2024, January 2025, and February 2025. 4. During an interview on 02/25/2025, beginning at 10:20 AM, The clinical manager admitted that they did not input test results, after administering the color blind test of PCT 3 on 07/17/2023.”
-
Assess B/P & Fluid Management Needs
The inspectors’ words, 601 words
“PA-ASSESS B/P, FLUID MANAGEMENT NEEDS CFR(s): 494.80(a)(2) The patient’s comprehensive assessment must include, but is not limited to, the following: Blood pressure, and fluid management needs. This Standard is not met as evidenced by: 47022 Based on record review and interview, the dialysis facility failed to evidence PCT 1 and PCT 2 notified RN 2 of patient’s low blood pressure prior to initiation of hemodialysis [HD] (a process to filter the blood when kidneys do not work normally) in 1 of 3 in center HD clinical records reviewed (Patient #5). Findings include: 1. A revised policy, dated 01/13/2025, titled, “Charge Nurse Notification Protocol,” indicated a systolic blood pressure less than 90 or a diastolic blood pressure less than 50 should be reported to the nurse by the direct patient care staff prior to initiation of HD. 2. A revised policy, dated 11/29/2022, titled, “Monitoring and Documentation of Patient Care During Treatment,” indicated patient status observations and interventions must be documented. The policy indicated patient care data entered manually must be documented at the time those actions are performed by the person providing the patient care. The policy indicated patient care data that cannot be documented when done must be documented as a late entry along, with a reason for the late entry, and include the time that activity occurred. The policy indicated information that was manually entered included notes documenting the patient status at each check, and interventions for unexpected situations. 3. A Treatment Flowsheet, dated 01/24/2025, for Patient #5 evidenced, at 10:29 AM, a pre-treatment dialysis low blood pressure of 87/47 (normal blood pressure 120/80) and failed to evidence documentation PCT 3 notified RN 2 of the low blood pressure and evidenced the following: A. The Treatment Flowsheet indicated at 10:31 AM HD treatment was initiated with a blood pressure of 90/60. B. The Treatment Flowsheet indicated at 10:32 AM blood pressure 103/63 followed by a 10:32 note by RN 2 that patient’s blood pressure dropped systolic [top number of blood pressure indicates pressure on the arteries when heart beating] less than 100 with Patient complaints of nausea/vomiting, 300 milliliters flush given and ultrafiltration [fluid removal] was turned off. C. 10:47 AM blood pressure 78/25. 4. A Treatment Flowsheet, dated 01/22/2025, for Patient #5 indicated, at 10:34 AM, HD treatment was initiated with a low blood pressure of 85/54 and failed to evidence documentation PCT 3 notified the RN of the low blood pressure prior to initiating treatment and evidenced the following: A. The Treatment Flowsheet indicated at 11:02 AM Patient’s blood pressure was 95/49. A RN 2 note at 11:03 AM indicated systolic blood pressure at start of HD was less than 100 and would continue to monitor. 5. A Treatment Flowsheet, dated 01/31/2025, for Patient #5 indicated, at 10:41 AM, HD treatment was initiated with a low blood pressure of 82/53 and failed to evidence documentation PCT 1 notified RN 2 of the low blood pressure prior to initiating treatment and evidenced the following: A. The Treatment Flowsheet indicated at 10:51 AM Patient’s blood pressure was low at 78/52, the RN was notified, and the ultrafiltration was turned off. B. The Treatment Flowsheet indicated at 11:02 AM Patient’s blood pressure was 100/67. 6. During an interview on 02/26/2025, beginning at 10:00 AM, RN 2 indicated the PCT should notify the RN of low blood pressure and document notification prior to initiating HD. 7. During an interview on 02/26/2025, beginning at 10:05 AM, PCT 1 indicated the PCT should notify the RN of systolic blood pressure less than 90 prior to initiating HD and the notification should be documented.”
-
Achieve Adequate Clearance
The inspectors’ words, 945 words
“POC-ACHIEVE ADEQUATE CLEARANCE CFR(s): 494.90(a)(1) Achieve and sustain the prescribed dose of dialysis to meet a hemodialysis Kt/V of at least 1.2 and a peritoneal dialysis weekly Kt/V of at least 1.7 or meet an alternative equivalent professionally-accepted clinical practice standard for adequacy of dialysis. This Standard is not met as evidenced by: 47022 Based on record review and interview, the dialysis facility failed to ensure patient hemodialysis [a process to clean the blood when kidneys do not work normally] prescription orders were adhered to in order to achieve and sustain the prescribed dose of dialysis to meet the adequacy of dialysis in 2 of 3 in center hemodialysis patient’s clinical records reviewed (Patient #5 and Patient #1). Findings include: 1. A revised policy dated 11/29/2022, titled, “Monitoring and Documentation of Patient Care During Treatment,” indicated before starting the patient treatment the treatment prescription would be documented indicating the staff reviewed and verified the patient treatment data. The policy indicated information that would be entered manually included but not limited to interventions for unexpected situations such as slowing blood flow for access problem, and if the patient’s prescription was not met for any reason a detailed progress note would be entered explaining why the prescription was not met and actions taken to address the situation. The policy indicated all patient care data that would be entered manually would be documented at the time those actions are performed by the person providing the patient care. The policy indicated if patient care data could not be documented when done would be documented as a late entry along with the time the activity actually occurred. The policy indicated information that would be entered manually would include interventions for unexpected situations such as slowing blood flow for access problems 2. A Treatment Flowsheet, dated 01/22/2025, indicated Patient #5’s blood flow rate[BFR] was to be 400 milliliters/minute [ml/min] and evidenced the following: A. During patient treatment, initiation at 10:31 AM, the BFR from 11:17 AM to 12:04 PM was at 375 ml/min, and failed to evidence documentation of the reason Patient did not receive the prescribed BFR. B. During patient treatment, the BFR from 12:17 PM to 12:32 PM was at 350ml/min, and failed to evidence documentation of the reason Patient did not receive the prescribed BFR. C. During patient treatment the BFR from 12:47 PM to 1:33 PM was at 300ml/min and failed to evidence documentation of reason Patient did not receive the prescribed BFR. 3. A Treatment Flowsheet, dated 01/31/2025, indicated Patient #5’s BFR was to be 400 ml/min and evidenced the following: During patient treatment, initiation at 10:41 AM, the BFR from 10:51 AM to 2:32 PM was at 350 ml/min, and failed to evidence documentation of the reason Patient did not receive the prescribed BFR. 4. A Treatment Flowsheet, dated 02/03/2025, indicated Patient #5’s BFR was to be 400ml/min and evidenced the following: A. During patient treatment, initiation at 10:34 AM, the BFR from 11:03 AM to 11:47 AM was at 375 ml/min, and failed to evidence documentation of the reason Patient did not receive the prescribed BFR. B. During patient treatment the BFR from 12:02 PM to 2:19 PM was at 350 ml/min, and failed to evidence documentation of the reason Patient did not receive the prescribed BFR. 5. During an interview on 02/26/2025, beginning at 10:00 AM, RN 2 indicated BFR changes from the prescription orders should be documented by the PCT or RN. 6. During an interview on 02/26/2025, beginning at 10:05 AM, PCT 1 indicated BFR changes should be documented after discussion with the RN. 51199 7. The clinical record for Patient #1 included two dialysis prescriptions, one dated 02/12/2025 and the other 02/21/2025, which indicated a Dialysis Flow Rate [DFR] (speed at which blood is pumped through a dialyzer during hemodialysis) of 400. A. A dialysis treatment record, dated on 02/12/2025, indicated that initiation of treatment, at 10:25 AM, began with a DFR at 800. The DFR was changed to 400 at 10:32 AM for the remainder of treatment. No progress note was entered explaining why the prescription was not followed. B. A treatment run sheet, dated 02/14/2025, indicated initiation of treatment was 6:28 AM and began with DFR of 400. The DFR was changed to 800 at 7:04 AM and remained at 800 for the remainder of treatment. No progress note was entered explaining why the prescription was not followed. C. A treatment run sheet, for 02/17/2025, indicated that initiation of treatment was at 7:24 AM and began with DFR at 600. The DFR remained at 600 for the remainder of treatment. No progress note was entered explaining why the prescription was not followed. D. A treatment run sheet for 02/19/2025 indicated that the initiation of treatment was at 6:24 AM and began with a DFR of 800. The DFR remained at 800 for the remainder of the treatment. No progress note was entered explaining why the prescription was not followed. E. A treatment run sheet for 02/21/2025 indicated that the initiation of treatment was at 6:14 AM and began with a DFR of 800. The DFR remained at 800 for the remainder of the treatment. No progress note was entered explaining why the prescription was not followed. 8. During an interview, on 02/25/2025 beginning at 10:10 AM, RN 2 indicated that they wrote the orders for DFR of 400, indicated the order should have been for DFR of 800 and was transcribed incorrectly by RN2. RN 2 indicated that he/she verbally instructed staff that Patient #1 should have a DFR of 800. RN 2 additionally indicated that a note was not entered with reason why prescription is not followed.”
-
Md Resp - Ensure All Adhere To P&P
The inspectors’ words, 215 words
“MD RESP-ENSURE ALL ADHERE TO P&P CFR(s): 494.150(c)(2)(i) The medical director must- (2) Ensure that- (i) All policies and procedures relative to patient admissions, patient care, infection control, and safety are adhered to by all individuals who treat patients in the facility, including attending physicians and nonphysician providers; This Standard is not met as evidenced by: 51199 Based on clinical record review, interview, and record review, the dialysis facility failed to ensure patients were evaluated by an RN, prior to their first dialysis treatment at the dialysis facility, in 1 of 1 clinical record reviewed of a new patient admission [Patient #1]. Findings include: 1. A revised policy, dated 06/20/2024, titled “IC07 Patient Assessment: Pre & Post Dialysis,” indicated that a new admission patient must have a full pre-dialysis assessment before the initiation of or at the beginning of the first treatment in the dialysis center. 2. During a clinical record review on 02/25/2025, a Nursing Initial Assessment, dated 02/14/2025, at 06:00, was noted as a late entry for admission date of 01/12/2025, no time noted. 3. During an interview on 02/25/2025, beginning at 10:10 AM, RN 2 indicated that he/she entered a late entry on 02/14/2025 for initial assessment of Patient #1 on 02/12/2025, and failed to include the time of the initial assessment.”
The one inspection in the last three years
| Date | Visit | What the record says |
|---|---|---|
| Feb 26, 2025 | Standard inspection | 7 deficiencies cited |
Is it certified?
- Medicare-certified dialysis facility, certified or last recertified on Jan 18, 2019.
- Run for profit.
- No For hospices, home health agencies, hospitals and dialysis facilities, CMS writes deficiencies at two levels. Standard is the usual one; condition-level is the more serious, when a problem is serious enough that the provider doesn’t meet a whole condition of taking part in Medicare. Source: CMS, State Operations Manual. deficiency on record in the last three years.
- Chain: American Renal Associates.
CMS, Dialysis Facility - Listing by Facility. Released Jul 15, 2026. Updated quarterly.
CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.
Has it been penalized?
- CMS doesn’t publish fines or other penalties for dialysis facilities.
- None of the deficiencies cited in the last three years came from an inspection that included a complaint investigation.
CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.
What does it offer?
- Offers in-center hemodialysis, peritoneal dialysis and home hemodialysis training.
- Doesn’t offer a shift starting at 5 p.m. or later.
- 16 dialysis stations.
- CMS doesn’t publish staffing levels for dialysis facilities.
CMS, Dialysis Facility - Listing by Facility and Patient survey (ICH CAHPS) - Facility. Released Jul 15, 2026. Updated quarterly.
Who owns it?
- Part of the American Renal Associates chain, as CMS lists it.
- CMS publishes no owners file for dialysis facilities, so no other owner is named.
CMS, Dialysis Facility - Listing by Facility. Released Jul 15, 2026. Updated quarterly.
How do patients fare?
- CMS rates it 3 of 5 stars (Jan 1, 2021 to Dec 31, 2024).
- Compared by CMS with what it expects for the facility’s patients: patient survival, as expected; hospital admissions, as expected; readmissions to hospital, as expected; blood transfusions, worse than expected; emergency department visits, as expected; emergency department visits within 30 days of a hospital stay, as expected; bloodstream infections, better than expected; patients dialysing through a fistula, better than expected; patients put on a kidney transplant waitlist in their first year of dialysis, as expected; patients on a kidney transplant waitlist, as expected.
- CMS gives no CMS rates some kinds of place from 1 to 5 stars, more stars meaning better on CMS’s own measures for that kind: for a nursing home, its health inspections, staffing and quality measures. A rating is CMS’s summary of those measures; it doesn’t promise good care. Source: CMS, Care Compare and the Five-Star Quality Rating System.: “Too few completed survey responses to report.”
CMS, Dialysis Facility - Listing by Facility and Patient survey (ICH CAHPS) - Facility. Released Jul 15, 2026. Updated quarterly.
| Measure | Rating |
|---|---|
| Star ratingCMS’s star rating for dialysis facilities, 1 to 5 | 3 of 5 |
| Patient survey ratingCMS star rating from its survey of the facility’s in-center hemodialysis patients (ICH CAHPS), 1 to 5 | Not rated |
How does it compare nearby?
- Of the 6 dialysis facilities CMS lists in Porter County, 6 have a star rating from CMS: 1 rated 5 of 5, 4 rated 3 of 5, 1 rated 2 of 5.
- CMS rates this one 3 of 5.
CMS, Dialysis Facility - Listing by Facility. Released Jul 15, 2026. Updated quarterly.
What the record doesn’t say
- CMS doesn’t publish fines or other penalties for dialysis facilities, so none are shown.
- Only complaints that led to a citation appear; complaints that didn’t aren’t published.
- QCOR says it has no dialysis inspection reports after February 19, 2026, while it moves to a new system: a later inspection is not shown yet.
- CMS doesn’t publish staffing levels for dialysis facilities.
- CMS publishes no owners file for dialysis facilities: the chain it lists is the only owner named.
Sources
-
Centers for Medicare & Medicaid Services, Dialysis Facility - Listing by Facility (23ew-n7w9).
Released Jul 15, 2026 and checked Oct 30, 2026. Updated quarterly. Public domain (U.S. Government work).
-
Centers for Medicare & Medicaid Services, Patient survey (ICH CAHPS) - Facility (59mq-zhts).
Released Jul 15, 2026 and checked Oct 30, 2026. Updated quarterly. Public domain (U.S. Government work).
-
Centers for Medicare & Medicaid Services, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies (ESRD_2567s_2018_to_2026YTD.xlsx).
Released Oct 28, 2026 and checked Oct 30, 2026. Updated monthly. Public domain (U.S. Government work).
If you believe something here is wrong, a correction starts with the agency whose record this copies: CMS. CMS’s own record is on Care Compare. If Hearth Record copied something wrongly, it will fix it and log the correction publicly, with its date: how corrections work.
This copy of the record was made on Oct 30, 2026.
From the facility
The public record above comes first. Anything the facility adds will appear here, below it, and say who wrote it.
Replies
None. Replies aren’t open yet. When they open, the facility will be able to answer any finding for free, and the reply will show beside that finding, unedited and dated.
Paid listing
None. Paid listings aren’t open yet. When they open, anything paid for will say “Paid by the facility”, and paying will never change a finding, a rating or the order of results.