Fmc-Indianapolis Northeast
A dialysis facility in Indianapolis, Indiana 46216
9140 Harrison Park Drive, Indianapolis, Indiana 46216. (317) 543-5128.
Watch and the shortlist are kept with a free account, on every device. Your watch list. CMS’s own record is on Care Compare.
The short answer
Record last released by CMS on Oct 28, 2026. We couldn’t read Centers for Medicare & Medicaid Services’ list since Nov 2, 2026: qcor.cms.gov now refuses our reader. This record is as of then.
- 3of 5 CMS’s star rating
- Not rated patient survey rating
- 2 deficiencies cited in the last three years
- 13 dialysis stations
Each figure’s source sits beside it, in its section below.
What these words mean3
- Star ratings
- CMS rates some kinds of place from 1 to 5 stars, more stars meaning better on CMS’s own measures for that kind: for a nursing home, its health inspections, staffing and quality measures. A rating is CMS’s summary of those measures; it doesn’t promise good care. Source: CMS, Care Compare and the Five-Star Quality Rating System.
- Inspection (survey)
- A visit by state inspectors, often unannounced, who check a place against the rules it must meet. For nursing homes and other places Medicare pays, CMS calls these visits surveys: a standard survey of a nursing home comes at least every 15 months, and a complaint survey whenever a complaint calls for one. Source: CMS; 42 CFR 488.308.
- Deficiency, citation, violation
- What inspectors write up when a place didn’t meet a rule: the rule, what they saw, and when. CMS calls it a deficiency; states may say citation or violation. It is the inspectors’ finding, not a court’s, and the place is usually asked for a plan to correct it. Source: CMS, statement of deficiencies (Form CMS-2567); each state’s licensing agency.
What did inspectors find?
The last inspection on record was on Jul 23, 2025: a standard inspection.
2 deficiencies cited in the last three years.
CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.
When those deficiencies happened
2 deficiencies in 1 month of the last 36. Last cited Jul 2025. Most serious: Standard-level. The last 3 years, to Oct 30, 2026.
| Jan | Feb | Mar | Apr | May | Jun | Jul | Aug | Sep | Oct | Nov | Dec | |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 2023 | Nov | Dec | ||||||||||
| 2024 | Jan | Feb | Mar | Apr | May | Jun | Jul | Aug | Sep | Oct | Nov | Dec |
| 2025 | Jan | Feb | Mar | Apr | May | Jun | Jul | Aug | Sep | Oct | Nov | Dec |
| 2026 | Jan | Feb | Mar | Apr | May | Jun | Jul | Aug | Sep | Oct |
Hover or focus a month to read it.
Hearth Record drew this from the dates and levels in the source’s own records.
Each deficiency, as cited
Rule titles as CMS’s inspectors cite them, set in sentence case.
CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.
Jul 23, 2025: standard inspection2 deficiencies
-
Qapi Indicator - Medical Injuries/Errors
The inspectors’ words, 612 words
“QAPI-INDICATOR-MEDICAL INJURIES/ERRORS CFR(s): 494.110(a)(2)(vi) The program must include, but not be limited to, the following: (vi) Medical injuries and medical errors identification. This Standard is not met as evidenced by: 51279 Based on record review and interview, the facility failed to evidence proper documentation and tracking of an adverse event for 1 of 1 active clinical records reviewed with a patient reporting an adverse event (Patient #2). Findings Include: 1. Review of a facility policy dated 11/04/2024 titled “ Quality Assessment and Performance Improvement Program” indicated but is not limited to, “ ... The program must reflect the complexity of the organization and services and must focus on indicators related to improved patient health outcomes and the prevention and reduction of medical errors ... QAPI is a continuous ongoing process that includes monitoring the data ... Elements to be reviewed will include: ... Patient Safety ...” 2. Review of a facility policy dated 02/06/2023 titled “Patient Safety Event Reporting and Documentation” indicated but is not limited to, “ ... When a Near Miss, Safety Event or Serious Safety Event occurs, staff are required to report, document, and review the event as noted in this policy ... Patient Safety Events should be reviewed during Quality Assessment and Performance Improvement (QAPI) Program ... Evaluate the safety reporting that includes category, event type and outcome ... Ensure documentation within the Patient Safety Data Entry Site has been completed ...” 3. Review of a facility document dated 07/21/2025 titled “Adverse Events Report” failed to evidence an infiltration of Patient #2’s arteriovenous access during the month of May. 4. Review of facility quality assurance meeting minutes dated 06/20/2025 evidenced the facility reviewed quality data from the month of May. The meeting minutes indicated but is not limited to, “ ... Safety- no issues ...” 5. Review of the clinical record for Patient #2 evidenced a Psychosocial Progress Note dated 05/31/2025 and signed by the MSW. The noted indicated but was not limited to, “ ... Patient did have infiltration today ...” Review of the clinical record for Patient #2 evidenced a Clinical Notes Report. The report failed to evidence documentation of the infiltration. During an interview on 07/22/2025 at 10:03 AM, Patient #2 indicated in the last month or two they infiltrated a few times. When queried what happened if there was an infiltration they indicated they continued treatment. During an interview with PCT 1 on 07/21/2025 at 2:11 PM, they explained if an incident happened they were to notify the nurse. During an interview with PCT 4 on 07/22/2025 at 1:40 PM, they indicated they followed the policy for reporting any adverse events. They indicated if an infiltration happened, it was considered an adverse event and should be reported and logged on their electronic medical record system. During an interview on 07/23/2025 at 12:54 PM, the Director of Operation (DO) 2 indicated a patient safety event or adverse event is considered the same thing. When queried what types of events are considered patient safety and should be reported, the DO 2 indicated a clotted dialyzer, blood loss, separation of systems, patient fall, cardiac event, or infiltration. When queried about the infiltration mentioned on the Psychosocial Progress Note dated 05/31/2025, the DO 2 indicated the infiltration should have been entered and recorded on the Adverse Event Log, but the event was not reported. The DO 2 indicated there was a red flag when reviewing the data, and there was no event documented. During an interview with RN 4 on 07/23/2025 at 2:35 PM, they revealed if an adverse event were to occur, they would notify the CM and document the adverse event in the electronic medical record.”
-
Medical Records - Complete, Accurate, Accessible
The inspectors’ words, 733 words
“MR-COMPLETE, ACCURATE, ACCESSIBLE CFR(s): 494.170 The dialysis facility must maintain complete, accurate, and accessible records on all patients, including home patients who elect to receive dialysis supplies and equipment from a supplier that is not a provider of ESRD services and all other home dialysis patients whose care is under the supervision of the facility. This Standard is not met as evidenced by: 47343 Based on record review and interview the facility failed to maintain a complete and accurate medical record by not obtaining and retaining a completed Against Medical Advice (AMA) Form for 3 of 3 active clinical records reviewed (Patient # 3, 4, and 7) with patients ending treatment early. Findings Include: 1. Review of a facility policy dated 06/16/2025 titled “Early Termination or Arriving Late for Treatment” indicated but is not limited to, “ ... If a patient insists on terminating treatment early and this has not been previously approved by the patient’s provider, the patient must take full responsibility for consequences of the missed or shortened treatment ... If a patient request to leave treatment early: ... RN is responsible to notify the provider, and document on the “AMA”, or Against Medical Advice form ... 2. A review of the active clinical record for Patient #3 evidenced the current Dialysis (treatment removing excess fluid and waste from the body when the kidneys are unable to function appropriately) Prescription Order dated 07/21/2025. The order included but was not limited to, “ ... 4 hrs (sic hours) 0 min (sic minutes) ...” A review of Patient #3’s active clinical record evidenced a treatment sheet dated 06/24/2025. It indicated the treatment was initiated on 6:20 AM and ended at 9:46 AM. Patient #3’s actual treatment duration was 3 hours and 25 minutes. The document indicated the patient requested to end the treatment early and an AMA form was completed. A review of Patient #3’s active clinical record evidenced a treatment sheet dated 07/05/2025. It indicated the treatment was initiated on 6:16 AM and ended at 9:29 AM. Patient #3’s actual treatment duration was 3 hours and 13 minutes. The treatment record failed to evidence why the treatment ended early. During an interview with Director of Operations 2 on 07/16/2025 at 2:40 PM, they indicated they were unable to find AMA forms for Patient #3’s treatment sheets dated 06/24/2025 and 07/05/2025. 3. A review of the active clinical record for Patient #4 evidenced the current Dialysis Prescription Order dated 07/21/2025. The order included but was not limited to, “ ... 4 hrs (sic hours) 15 min (sic minutes) ...” A review of Patient #4’s active clinical record evidenced a treatment sheet dated 07/01/2025. It indicated the treatment was initiated on 1:33 PM and ended at 4:47 PM. Patient #4’s actual treatment duration was 3 hours and 14 minutes. The treatment record evidenced the patient requested to end the treatment early due to foot pain. During an interview the Director of Operations 2 and Clinical Manager on 07/16/2025 at 12:55 PM, they indicated they were unable to find the AMA form completed for Patient #4’s treatment sheet dated 07/01/2025. 51279 4. Review of the clinical record for Patient # 7 evidenced a dialysis order dated 07/21/2025, for a prescribed treatment duration time of 4 hours and 45 minutes. A review of the treatment flowsheet dated 07/11/2025 evidenced a prescribed treatment duration of 4 hours and 45 minutes. The treatment flowsheet indicated the actual duration of dialysis treatment for 3 hours and 44 minutes. The treatment flowsheet failed to indicate why Patient #7 terminated treatment early. The clinical record for Patient #7 failed to evidence an Against Medical Advice form. During an interview on 07/23/2025 at 9:03 AM, the Clinical Manager confirmed the facility was unable to locate the Against Medical Advice form for Patient #7. 5. During an interview with Director of Operations 2 on 07/16/2025 at 12:06 PM, they explained if the patient terminated the treatment early, an AMA form was to be completed, and the physician notified. 6. During an interview with PCT 4 on 07/16/2025 at 2:24 PM, they indicated an AMA form was to be completed for any reason a patient wanted to come off of their treatment early. 7. During an interview with RN 4 on 07/16/2025 at 2:35 PM, they indicated if a patient did not want to finish their dialysis treatment, an AMA form should be completed.”
The one inspection in the last three years
| Date | Visit | What the record says |
|---|---|---|
| Jul 23, 2025 | Standard inspection | 2 deficiencies cited |
Is it certified?
- Medicare-certified dialysis facility, certified or last recertified on Oct 25, 2018.
- Run as a non-profit.
- No For hospices, home health agencies, hospitals and dialysis facilities, CMS writes deficiencies at two levels. Standard is the usual one; condition-level is the more serious, when a problem is serious enough that the provider doesn’t meet a whole condition of taking part in Medicare. Source: CMS, State Operations Manual. deficiency on record in the last three years.
- Chain: Fresenius Medical Care.
CMS, Dialysis Facility - Listing by Facility. Released Jul 15, 2026. Updated quarterly.
CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.
Has it been penalized?
- CMS doesn’t publish fines or other penalties for dialysis facilities.
- None of the deficiencies cited in the last three years came from an inspection that included a complaint investigation.
CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.
What does it offer?
- Offers in-center hemodialysis.
- Doesn’t offer peritoneal dialysis, home hemodialysis training and a shift starting at 5 p.m. or later.
- 13 dialysis stations.
- CMS doesn’t publish staffing levels for dialysis facilities.
CMS, Dialysis Facility - Listing by Facility and Patient survey (ICH CAHPS) - Facility. Released Jul 15, 2026. Updated quarterly.
Who owns it?
- Part of the Fresenius Medical Care chain, as CMS lists it.
- CMS publishes no owners file for dialysis facilities, so no other owner is named.
CMS, Dialysis Facility - Listing by Facility. Released Jul 15, 2026. Updated quarterly.
How do patients fare?
- CMS rates it 3 of 5 stars (Jan 1, 2021 to Dec 31, 2024).
- Compared by CMS with what it expects for the facility’s patients: patient survival, as expected; hospital admissions, as expected; readmissions to hospital, as expected; emergency department visits, as expected; emergency department visits within 30 days of a hospital stay, worse than expected; bloodstream infections, better than expected; patients dialysing through a fistula, as expected; patients put on a kidney transplant waitlist in their first year of dialysis, as expected; patients on a kidney transplant waitlist, as expected.
- CMS gives no CMS rates some kinds of place from 1 to 5 stars, more stars meaning better on CMS’s own measures for that kind: for a nursing home, its health inspections, staffing and quality measures. A rating is CMS’s summary of those measures; it doesn’t promise good care. Source: CMS, Care Compare and the Five-Star Quality Rating System.: “Too few completed survey responses to report.”
CMS, Dialysis Facility - Listing by Facility and Patient survey (ICH CAHPS) - Facility. Released Jul 15, 2026. Updated quarterly.
| Measure | Rating |
|---|---|
| Star ratingCMS’s star rating for dialysis facilities, 1 to 5 | 3 of 5 |
| Patient survey ratingCMS star rating from its survey of the facility’s in-center hemodialysis patients (ICH CAHPS), 1 to 5 | Not rated |
How does it compare nearby?
- Of the 25 dialysis facilities CMS lists in Marion County, 22 have a star rating from CMS: 8 rated 3 of 5, 7 rated 2 of 5, 7 rated 1 of 5.
- CMS rates this one 3 of 5.
CMS, Dialysis Facility - Listing by Facility. Released Jul 15, 2026. Updated quarterly.
What the record doesn’t say
- CMS doesn’t publish fines or other penalties for dialysis facilities, so none are shown.
- Only complaints that led to a citation appear; complaints that didn’t aren’t published.
- QCOR says it has no dialysis inspection reports after February 19, 2026, while it moves to a new system: a later inspection is not shown yet.
- CMS doesn’t publish staffing levels for dialysis facilities.
- CMS publishes no owners file for dialysis facilities: the chain it lists is the only owner named.
Sources
-
Centers for Medicare & Medicaid Services, Dialysis Facility - Listing by Facility (23ew-n7w9).
Released Jul 15, 2026 and checked Oct 30, 2026. Updated quarterly. Public domain (U.S. Government work).
-
Centers for Medicare & Medicaid Services, Patient survey (ICH CAHPS) - Facility (59mq-zhts).
Released Jul 15, 2026 and checked Oct 30, 2026. Updated quarterly. Public domain (U.S. Government work).
-
Centers for Medicare & Medicaid Services, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies (ESRD_2567s_2018_to_2026YTD.xlsx).
Released Oct 28, 2026 and checked Oct 30, 2026. Updated monthly. Public domain (U.S. Government work).
If you believe something here is wrong, a correction starts with the agency whose record this copies: CMS. CMS’s own record is on Care Compare. If Hearth Record copied something wrongly, it will fix it and log the correction publicly, with its date: how corrections work.
This copy of the record was made on Oct 30, 2026.