Hearth Record

Schererville Dialysis Center

A dialysis facility in Schererville, Indiana 46375

1534 Us Highway 41, Schererville, Indiana 46375. (219) 322-5448.

CMS’s own record, on Care Compare

Watch and the shortlist are kept with a free account, on every device. Your watch list. CMS’s own record is on Care Compare.

The short answer

Record last released by CMS on Oct 28, 2026. We couldn’t read Centers for Medicare & Medicaid Services’ list since Nov 2, 2026: qcor.cms.gov now refuses our reader. This record is as of then.

The last 24 months 7 deficiencies in 1 month of the last 36. Last cited May 2025. Most serious: Standard-level. Every month

Each figure’s source sits beside it, in its section below.

What these words mean3
Star ratings
CMS rates some kinds of place from 1 to 5 stars, more stars meaning better on CMS’s own measures for that kind: for a nursing home, its health inspections, staffing and quality measures. A rating is CMS’s summary of those measures; it doesn’t promise good care. Source: CMS, Care Compare and the Five-Star Quality Rating System.
Inspection (survey)
A visit by state inspectors, often unannounced, who check a place against the rules it must meet. For nursing homes and other places Medicare pays, CMS calls these visits surveys: a standard survey of a nursing home comes at least every 15 months, and a complaint survey whenever a complaint calls for one. Source: CMS; 42 CFR 488.308.
Deficiency, citation, violation
What inspectors write up when a place didn’t meet a rule: the rule, what they saw, and when. CMS calls it a deficiency; states may say citation or violation. It is the inspectors’ finding, not a court’s, and the place is usually asked for a plan to correct it. Source: CMS, statement of deficiencies (Form CMS-2567); each state’s licensing agency.

What did inspectors find?

The last inspection on record was on May 7, 2025: a standard inspection.

7 deficiencies cited in the last three years.

Source:

CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.

When those deficiencies happened

7 deficiencies in 1 month of the last 36. Last cited May 2025. Most serious: Standard-level. The last 3 years, to Oct 30, 2026.

7 deficiencies by month over the last 3 years. Each cell is one month.
JanFebMarAprMayJunJulAugSepOctNovDec
2023 NovDec
2024 JanFebMarAprMayJunJulAugSepOctNovDec
2025 JanFebMarAprMayJunJulAugSepOctNovDec
2026 JanFebMarAprMayJunJulAugSepOct

Hover or focus a month to read it.

No visit on record Visited, nothing cited A stronger orange is more serious, on its source’s own levels, read onto four bands: from the least serious it publishes to the most
Source:

Hearth Record drew this from the dates and levels in the source’s own records.

Each deficiency, as cited

Rule titles as CMS’s inspectors cite them, set in sentence case.

Source:

CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.

May 7, 2025: standard inspection7 deficiencies
  • Ic - Wear Gloves/Hand Hygiene

    The inspectors’ words, 421 words

    “IC-WEAR GLOVES/HAND HYGIENE CFR(s): 494.30(a)(1) Wear disposable gloves when caring for the patient or touching the patient’s equipment at the dialysis station. Staff must remove gloves and wash hands between each patient or station. This Standard is not met as evidenced by: 51199 Based on observation, record review, and interview, the dialysis facility failed to ensure staff removed gloves and performed hand hygiene between patients and stations, and after glove removal in 1 of 1 observations of discontinuation of hemodialysis [HD] (a process to filter the blood of a patient whose kidneys do not work normally) with a central venous catheter [CVC] (catheter into large vein), 1 of 2 observations of access of an arteriovenous fistula [AVF] (dialysis access) for initiation of HD, and 2 of 2 observations of discontinuation of HD and post dialysis access care for AVF. Findings include: 1. A revised policy, dated 11/29/2022, titled “G40 Infection Control” indicated hands should be washed after gloves are removed, between patient contact, and after touching blood, body fluids, and contaminated items. The policy indicated antiseptic hand cleaners may be used in place of soap and water if hands are not soiled, during emergencies, or if there has been no exposure to or contact with blood or potentially infectious materials. 2. During an observation on 05/07/2025, beginning at 1:54 PM, at station 17, PCT 5 discontinued HD treatment for Patient 12. PCT 5 reinfused the HD machine and failed to remove gloves, perform hand hygiene, and don new gloves prior to disconnecting Patient 12 from the HD machine. 3. During an observation on 05/05/2025, beginning at 10:44 AM, at station 6, PCT 4 accessed Patient 7’s AVF. PCT 4 located and palpated the cannulation sites, and failed to perform hand hygiene and don clean gloves prior to disinfecting the cannulation sites. 4. During an observation on 05/05/2025, beginning at 10:58 AM, at station 3, PCT 4 discontinued HD for Patient 6. PCT 4 reinfused the HD machine and failed to remove gloves, perform hand hygiene, and don clean gloves prior to removing the needles from the patient. 5. During an observation on 05/05/2025, beginning at 9:04 AM, at station 11, PCT 1 discontinued HD for Patient 4. PCT 1 removed the needles from Patient 4 and failed to perform hand hygiene prior to donning new gloves and placing bandage on needle sites. 6. During an interview on 05/06/2025, beginning at 11:10 AM, PCT 2 indicated that hand hygiene and glove change should occur before patient contact and using the HD machine.”

    Rule V0113. Standard-level.

  • Pe - Hemodialysis Patients In View During Treatments

    The inspectors’ words, 201 words

    “PE-HD PTS IN VIEW DURING TREATMENTS CFR(s): 494.60(c)(4) Patients must be in view of staff during hemodialysis treatment to ensure patient safety, (video surveillance will not meet this requirement). This Standard is not met as evidenced by: 51199 Based on observation, interview, and record review the dialysis facility failed to ensure patient safety by ensuring the hemodialysis [HD] (a process to filter the blood of a patient whose kidneys do not work normally) access site was visible during HD treatment in 1 of 3 observation periods of in-center HD treatment. Findings include: 1. A revised policy, dated 11/29/2022, titled “IC08 Monitoring & Documentation of Patient Care During Treatment” indicated that a patient’s vascular access should remain uncovered and visible throughout the course of the patient’s treatment. 2. During an observation on 05/07/2025, beginning at 12:50 PM, at Station #11, Patient 9’s left thigh arteriovenous graft [AVG] (dialysis access) was covered with a blanket. The blanket covered the patient from the neck to the toes through the observation period (12:50 PM - 14:03). 3. During an interview on 05/06/2025, beginning at 11:10 AM, PCT 2 indicated that patient access sites need to visible to staff at all times while receiving HD treatment.”

    Rule V0407. Standard-level.

  • Manage Volume Status

    The inspectors’ words, 705 words

    “POC-MANAGE VOLUME STATUS CFR(s): 494.90(a)(1) The plan of care must address, but not be limited to, the following: (1) Dose of dialysis. The interdisciplinary team must provide the necessary care and services to manage the patient’s volume status; This Standard is not met as evidenced by: 51199 Based on record review and interview, the dialysis facility failed to ensure patient hemodialysis [HD] (a process to filter the blood of a patient whose kidneys do not work normally) prescription orders were adhered to in order to achieve and sustain the prescribed dose of dialysis to manage patients’ fluid volume in 2 of 5 in-center hemodialysis clinical records reviewed and 1 of 5 in-center observations of verification of dialysis treatment prescription delivery. Findings include: 1. A revised policy, dated 11/29/2022, titled, “IC08 Monitoring and Documentation of Patient Care During Treatment” indicated two signatures were required before starting the patient’s prescription in the electronic documentation system. The policy indicated data that would be documented at least every 30 minutes would include dialysate flow rate (DFR). Additionally, the policy indicated if the patient’s prescription was not met for any reason, a detailed progress note should be entered explaining why the prescription was not met and actions taken to address the situation. 2. During an in-center observation on 05/07/2025, beginning at 8:57 AM, at station #15, Patient 10 had a DFR running at 600 and a dialysate solution of 2K+ 2.5Ca+. A Treatment Flow Sheet, dated 05/07/2025, for Patient 10, indicated that the prescribed DFR was 800 and the prescribed dialysate was 2K+2Ca+. The Treatment Flow Sheet additionally indicated that the HD treatment was initiated by PCT 5 and was verified by PCT 4. During an interview on 05/07/2025, beginning at 8:58 AM, PCT 5 indicated that the reason for Patient 10 having the wrong DFR and dialysate was because Patient 10 was going to be discharged soon. During an interview on 05/07/2025, beginning at 10:10 AM, Administrative Staff 2 indicated that the DFR and dialysate prescription should match what is running on the HD Machine. Additionally, Administrative Staff 2 indicated that the prescribed dialysate is administered from a gallon jug, and the dialysate that was running is administered from the wall box. Administration 2 indicated that a patient should not be hooked up to an incorrect dialysate solution via the wall box in lieu of opening a new jug of prescribed dialysate. 3. A Clinical Record Review on 05/06/2025, for Patient 4, indicated that the prescribed DFR was 600. The HD Treatment Flowsheets indicated the following: A. On 04/14/2025, the DFR was run at 800 from 6:30 AM until treatment ended (9:00 AM). B.On 04/18/2025, the DFR was run at 500 when treatment was initiated at 5:27 until 5:32 AM. C.On 04/21/2025, the DFR was run at 500 when the treatment was initiated (5:35 AM) until the time treatment ended (9:07 AM). D.On 04/25/2025, the DFR was run at 500 from the time treatment was initiated (5:30 AM) until the time treatment was terminated (9:06 AM) E.On 05/02/2025, the DFR was run at 500 from the time treatment was initiated (5:30 AM) until the time treatment was terminated (9:00 AM) 4. A Clinical Record Review on 05/06/2025, for Patient 5, indicated that the prescribed DFR was 600. The HD Treatment Flowsheets indicated the following: A.On 04/10/2025, the DFR was run at 800 from the time the treatment was initiated (9:36 AM) until the time the treatment was terminated (12:04 PM). It was noted that PCT 2 indicated the change in DFR was per RN 2. No new physician order was made for this change, nor was it noted that the MD was contacted. B. On 04/15/2025, the DFR was run at 500 from the time the treatment was initiated (10:18 AM) until 10:32 AM. C. On 04/22/2025, the DFR was run at 800 from the time treatment was initiated (10:00 AM) until 10:31 AM. D. On 4/26/2025, the DFR was run at 500 from the time treatment was initiated (9:39 AM) until 10:00 AM. 5. During an interview on 05/07/2025, beginning at 10:10 AM, Administrative Staff 2 indicated that there should be no discrepancy between the dialysis prescription and what is administered unless there is a new MD order.”

    Rule V0543. Standard-level.

  • Vascular Access - Monitor/Referrals

    The inspectors’ words, 268 words

    “POC-VASCULAR ACCESS-MONITOR/REFERRALS CFR(s): 494.90(a)(5) The interdisciplinary team must provide vascular access monitoring and appropriate, timely referrals to achieve and sustain vascular access. The hemodialysis patient must be evaluated for the appropriate vascular access type, taking into consideration co-morbid conditions, other risk factors, and whether the patient is a potential candidate for arteriovenous fistula placement. This Standard is not met as evidenced by: 51199 Based on observation, record review, and interview, the dialysis facility failed to ensure appropriate vascular access care when PCT 1 disinfected the arteriovenous fistula [AVF] (entry into the blood vessel for hemodialysis [HD])(a process to clean the blood of a patient whose kidneys do not work normally), then repalpated the disinfected area prior to cannulation (needle insertion) in 1 of 2 AVF cannulations observed. Findings include: 1. A revised policy, dated 06/20/2024, titled “IC04A AVF/AVG Cannulation, Treatment Initiation and Termination” indicates that the needle insertion site should be disinfected and allowed to dry, and if the access is touched after being disinfected, it must be disinfected again before needle insertion. 2. During an observation on 05/05/2025, beginning at 10:39AM, at Station #10, PCT 1 disinfected the cannulation site of Patient 8, allowed it to dry, and then palpated the cannulation site and inserted the needle. PCT 1 then palpated the second cannulation site and inserted the needle without disinfecting between palpation and needle insertion. PCT 1 failed to disinfect both cannulation sites after palpating the sites prior to cannulation. 3. During an interview on 05/06/2025, beginning at 11:10AM, PCT 2 indicated that after disinfecting the cannulation site, needle insertion should occur next without repalpating site.”

    Rule V0550. Standard-level.

  • Measure, Analyze And Track Quality Indicators

    The inspectors’ words, 264 words

    “QAPI-MEASURE/ANALYZE/TRACK QUAL INDICATORS CFR(s): 494.110(a)(2) The dialysis facility must measure, analyze, and track quality indicators or other aspects of performance that the facility adopts or develops that reflect processes of care and facility operations. These performance components must influence or relate to the desired outcomes or be the outcomes themselves. This Standard is not met as evidenced by: 51199 Based on record review and interview, the dialysis facility’s Quality Assessment and Performance Improvement [QAPI] Program failed to measure, analyze and track quality indicators for patient outcomes related to fluid and blood pressure management in 1 of 1 facility. Findings include: 1. A revised policy, dated 01/13/2025, titled, “G09 Quality Assurance and Performance Improvement (QAPI),” indicated the QAPI program would look at indicators for patients and trend outcomes to identify commonalities among patients who do not reach expected targets. Additionally, the policy indicated that the dialysis facility should regularly review data to identify areas for improvement and take appropriate action to improve outcomes and processes. 2. A Dialysis Facility Report, for 2023, indicated the dialysis facility ultrafiltration rate (removal of fluid from a patient) for hemodialysis [HD] (a process to filter the blood of a patient whose kidneys do not work normally) was 11.8% which was above the national average of 7.8%. 3. During QAPI Program review on 05/07/2025, the QAPI program failed to evidence an indicator for tracking fluid and blood pressure management. 4. During an interview, on 05/07/2025, beginning at 10:10 AM, the Acting Clinical Manager, Administrative Staff 2, indicated the dialysis facility’s QAPI Program does not monitor fluid and blood pressure management.”

    Rule V0628. Standard-level.

  • Md Resp - Ensure All Adhere To P&P

    The inspectors’ words, 236 words

    “MD RESP-ENSURE ALL ADHERE TO P&P CFR(s): 494.150(c)(2)(i) The medical director must- (2) Ensure that- (i) All policies and procedures relative to patient admissions, patient care, infection control, and safety are adhered to by all individuals who treat patients in the facility, including attending physicians and nonphysician providers; This Standard is not met as evidenced by: 51199 Based on record review and interview, the dialysis facility failed to ensure that all policies and procedures relative to patient admissions were adhered to in 1 of 1 clinical record reviews of new admission patients. Findings include: 1. A revised policy, dated 01/13/2025, titled “G04 Admission & Discharge of Patients” indicated that prior to the initiation of any patient’s first treatment at the facility, a Nursing Initial Assessment will be completed and documented in the patient’s medical record. 2. A clinical record review on 05/06/2025, for Patient 1, indicated that Patient 1’s first treatment was initiated on 04/29/2025, and the Nursing Initial Assessment was completed and documented on 05/05/2025. 3. During an interview on 05/07/2025, beginning at 10:10 AM, Administrative Staff 2 indicated that Patient 1’s Nursing Initial Assessment was not completed prior to the initiation of the first treatment, and was competed on 05/05/2025. Additionally Administrative Staff 2 indicated that it is the policy to complete this assessment prior to first treatment initiation and if it is not completed at that time, it is considered an adverse event.”

    Rule V0715. Standard-level.

  • Medical Records - Complete, Accurate, Accessible

    The inspectors’ words, 391 words

    “MR-COMPLETE, ACCURATE, ACCESSIBLE CFR(s): 494.170 The dialysis facility must maintain complete, accurate, and accessible records on all patients, including home patients who elect to receive dialysis supplies and equipment from a supplier that is not a provider of ESRD services and all other home dialysis patients whose care is under the supervision of the facility. This Standard is not met as evidenced by: 51199 Based on observation, record review, and interview, the dialysis facility failed to maintain accurate records in 1 of 1 in-center observation of incorrect dialysis prescription delivery. Findings include: 1. A revised policy, dated 11/29/2022, titled, “IC08 Monitoring and Documentation of Patient Care During Treatment” indicated two signatures were required before starting the patient’s prescription in the electronic documentation system. The policy indicated data that would be documented at least every 30 minutes would include dialysate flow rate (DFR). Additionally, the policy indicated if the patient’s prescription was not met for any reason, a detailed progress note should be entered explaining why the prescription was not met and actions taken to address the situation. 2. During an in-center observation period on 05/07/2025, beginning at 8:57 AM, at station #15, Patient 10 had a dialysate solution being administered of 2K+ 2.5Ca+. The prescription order for Patient 10 was for a dialysate solution of 2K+ 2Ca+. 3. A Treatment Flow Sheet, dated 05/07/2025, for Patient 10, indicated that the prescribed dialysate of 2K+ 2Ca+ was running from the time of treatment initiation (6:13 AM) until the time of treatment termination (9:24 AM). There was no notation of a different dialysate being administered for any length of time during the course of the treatment. 4. During an interview on 05/07/2025, beginning at 8:58 AM, PCT 5 indicated that the reason for Patient 10 having the wrong dialysate was because Patient 10 was going to be discharged soon. 5. During an interview on 05/07/2025, beginning at 10:10 AM, Administrative Staff 2 indicated that the dialysate prescription should match what is running on the HD Machine. Additionally, Administrative Staff 2 indicated that the prescribed dialysate is administered from a gallon jug, and the dialysate that was running is administered from the wall box. Administration 2 indicated that a patient should not be hooked up to an incorrect dialysate solution via the wall box in lieu of opening a new jug of prescribed dialysate.”

    Rule V0726. Standard-level.

All 2 inspections in the last three years
Inspections on record
DateVisitWhat the record says
May 7, 2025Standard inspection7 deficiencies cited
Oct 9, 2024Complaint inspectionNo deficiencies cited

Is it certified?

  • Medicare-certified dialysis facility, certified or last recertified on Sep 2, 2016.
  • Run for profit.
  • No deficiency on record in the last three years.
  • Chain: American Renal Associates.
Source:

CMS, Dialysis Facility - Listing by Facility. Released Jul 15, 2026. Updated quarterly.

CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.

Has it been penalized?

  • CMS doesn’t publish fines or other penalties for dialysis facilities.
  • None of the deficiencies cited in the last three years came from an inspection that included a complaint investigation.
Source:

CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.

What does it offer?

  • Offers in-center hemodialysis, peritoneal dialysis and home hemodialysis training.
  • Doesn’t offer a shift starting at 5 p.m. or later.
  • 17 dialysis stations.
  • CMS doesn’t publish staffing levels for dialysis facilities.
Source:

CMS, Dialysis Facility - Listing by Facility and Patient survey (ICH CAHPS) - Facility. Released Jul 15, 2026. Updated quarterly.

Who owns it?

  • Part of the American Renal Associates chain, as CMS lists it.
  • CMS publishes no owners file for dialysis facilities, so no other owner is named.
Source:

CMS, Dialysis Facility - Listing by Facility. Released Jul 15, 2026. Updated quarterly.

How do patients fare?

  • CMS rates it 3 of 5 stars (Jan 1, 2021 to Dec 31, 2024).
  • Compared by CMS with what it expects for the facility’s patients: patient survival, as expected; hospital admissions, as expected; readmissions to hospital, as expected; blood transfusions, as expected; emergency department visits, as expected; emergency department visits within 30 days of a hospital stay, as expected; bloodstream infections, better than expected; patients dialysing through a fistula, as expected; patients on a kidney transplant waitlist, as expected.
  • CMS gives no : “Too few completed survey responses to report.”
Source:

CMS, Dialysis Facility - Listing by Facility and Patient survey (ICH CAHPS) - Facility. Released Jul 15, 2026. Updated quarterly.

Ratings and measures, as published
MeasureRating
Star ratingCMS’s star rating for dialysis facilities, 1 to 53 of 5
Patient survey ratingCMS star rating from its survey of the facility’s in-center hemodialysis patients (ICH CAHPS), 1 to 5Not rated

How does it compare nearby?

  • Of the 21 dialysis facilities CMS lists in Lake County, 19 have a star rating from CMS: 2 rated 5 of 5, 2 rated 4 of 5, 6 rated 3 of 5, 6 rated 2 of 5, 3 rated 1 of 5.
  • CMS rates this one 3 of 5.
Source:

CMS, Dialysis Facility - Listing by Facility. Released Jul 15, 2026. Updated quarterly.

What the record doesn’t say

  • CMS doesn’t publish fines or other penalties for dialysis facilities, so none are shown.
  • Only complaints that led to a citation appear; complaints that didn’t aren’t published.
  • QCOR says it has no dialysis inspection reports after February 19, 2026, while it moves to a new system: a later inspection is not shown yet.
  • CMS doesn’t publish staffing levels for dialysis facilities.
  • CMS publishes no owners file for dialysis facilities: the chain it lists is the only owner named.

Sources

If you believe something here is wrong, a correction starts with the agency whose record this copies: CMS. CMS’s own record is on Care Compare. If Hearth Record copied something wrongly, it will fix it and log the correction publicly, with its date: how corrections work.

Source:

This copy of the record was made on Oct 30, 2026.

From the facility

The public record above comes first. Anything the facility adds will appear here, below it, and say who wrote it.

Replies

None. Replies aren’t open yet. When they open, the facility will be able to answer any finding for free, and the reply will show beside that finding, unedited and dated.

Paid listing

None. Paid listings aren’t open yet. When they open, anything paid for will say “Paid by the facility”, and paying will never change a finding, a rating or the order of results.

How to read a record

Four things every record does, shown on an example record made up for this guide.

An example record, made up for this guide

An example nursing home

Made up for this guide: no real place is shown

Not fully inspected in over two years (CMS flag)

11 health citations at the latest inspection cycle

The state average is 14.3.

Source:

CMS, State and US Averages and Health Deficiencies. Released Oct 28, 2026. Updated monthly.

From the homeNone yet. Replies and paid listings aren’t open, and when they open they will sit here, below the record.

1 of 4

Every fact names its source.

Who published it, when, and how often it changes sit beside each fact, with a link to the agency’s own file.

Sign in

A free account keeps your watch list, shortlists, comparisons and saved searches on every device, and can email you when something you watch changes. Browsing never needs one.