Fmc - East Chicago Dialysis Center

A dialysis facility in East Chicago, Indiana 46312

4016 Main Street, East Chicago, Indiana 46312. (219) 398-9338.

CMS’s own record, on Care Compare

Watch and the shortlist are kept with a free account, on every device. Your watch list. CMS’s own record is on Care Compare.

The short answer

Record last released by CMS on Oct 28, 2026. We couldn’t read Centers for Medicare & Medicaid Services’ list since Nov 2, 2026: qcor.cms.gov now refuses our reader. This record is as of then.

The last 24 months 6 deficiencies in 1 month of the last 36. Last cited Jan 2025. Most serious: Standard-level. Every month

Each figure’s source sits beside it, in its section below.

What these words mean3
Star ratings
CMS rates some kinds of place from 1 to 5 stars, more stars meaning better on CMS’s own measures for that kind: for a nursing home, its health inspections, staffing and quality measures. A rating is CMS’s summary of those measures; it doesn’t promise good care. Source: CMS, Care Compare and the Five-Star Quality Rating System.
Inspection (survey)
A visit by state inspectors, often unannounced, who check a place against the rules it must meet. For nursing homes and other places Medicare pays, CMS calls these visits surveys: a standard survey of a nursing home comes at least every 15 months, and a complaint survey whenever a complaint calls for one. Source: CMS; 42 CFR 488.308.
Deficiency, citation, violation
What inspectors write up when a place didn’t meet a rule: the rule, what they saw, and when. CMS calls it a deficiency; states may say citation or violation. It is the inspectors’ finding, not a court’s, and the place is usually asked for a plan to correct it. Source: CMS, statement of deficiencies (Form CMS-2567); each state’s licensing agency.

What did inspectors find?

The last inspection on record was on Jan 13, 2025: a standard inspection.

6 deficiencies cited in the last three years.

Source:

CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.

When those deficiencies happened

6 deficiencies in 1 month of the last 36. Last cited Jan 2025. Most serious: Standard-level. The last 3 years, to Oct 30, 2026.

6 deficiencies by month over the last 3 years. Each cell is one month.
JanFebMarAprMayJunJulAugSepOctNovDec
2023 NovDec
2024 JanFebMarAprMayJunJulAugSepOctNovDec
2025 JanFebMarAprMayJunJulAugSepOctNovDec
2026 JanFebMarAprMayJunJulAugSepOct

Hover or focus a month to read it.

No visit on record Visited, nothing cited A stronger orange is more serious, on its source’s own levels, read onto four bands: from the least serious it publishes to the most
Source:

Hearth Record drew this from the dates and levels in the source’s own records.

Each deficiency, as cited

Rule titles as CMS’s inspectors cite them, set in sentence case.

Source:

CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.

Jan 13, 2025: standard inspection6 deficiencies
  • Ic - Wear Gloves/Hand Hygiene

    The inspectors’ words, 841 words

    “IC-WEAR GLOVES/HAND HYGIENE CFR(s): 494.30(a)(1) Wear disposable gloves when caring for the patient or touching the patient’s equipment at the dialysis station. Staff must remove gloves and wash hands between each patient or station. This Standard is not met as evidenced by: 47022 Based on observation, record review, and interview, the dialysis facility failed to ensure PCT 2 and PCT 3 performed hand hygiene, hand sanitizing with an alcohol based antiseptic or hand washing, after glove removal, between patients and when moving between patients’ hemodialysis [HD] (a process to filter the blood of a patient whose kidneys do not work normally) stations durin 1 of 5 observations conducted of PCT 2 and 1 of 1 observations of PCT 3. Findings include: 1. A policy dated 11/06/2023, titled, “Hand Hygiene,” indicated an alcohol-based hand rub or hand washing with an antimicrobial soap and water should be performed before and after direct contact with patients, immediately after removing gloves, and after contact with inanimate objects near a patient. 2. During an observation on 01/09/2025, beginning at 9:42 AM, PCT 2 was typing on the computer keyboard at station #16, PCT 2 removed her gloves, and applied new gloves; without completing hand hygiene she entered station #14 and obtained Patient #16’s blood pressure and placed a barrier under Patient’s right arm. Without hand hygiene PCT 2 entered station #13, she picked up Patient #15’s coat and escorted Patient #15 to the scale, then PCT 2 opened the door to the foyer, and Patient #15 left. PCT 2 then returned to station #13, typed on the computer keyboard with the same gloves, then removed their gloves and applied new gloves without performing hand hygiene. 3. During an observation on 01/09/2025, beginning at 9:42 AM, PCT 2 was at station #14 with Patient #16, she removed 1 line from Patient’s arteriovenous fistula [AVF](access for HD), PCT 2 removed gloves and gown, applied new gown and gloves without performing hand hygiene. 4. During an observation, on 01/09/2025, beginning at 9:42 AM, PCT 2 was at station #13 cleaning the station chair and then entered station #14 with the same gloves to clean the front of the computer while Patient #16 remained at station #14, PCT 2 then removed her gloves, applied new gloves without performing hand hygiene. 5. During an observation on 01/09/2025, beginning at 10:15 AM, PCT 2 went to station #15 with Patient #17, PCT 2 removed her gloves, applied new gloves without performing hand hygiene and typed on station #15’s computer keyboard, PCT 2 then entered station #14 with the same gloves and touched the HD supplies on the tray side table, PCT 2 removed her gloves without performing hand hygiene and entered station #13 to set up the intravenous saline tubing, PCT 2 then removed her gloves, and applied new gloves without performing hand hygiene, PCT 2 then entered station #14 with Patient #16 and removed the 2nd line of the AVF, PCT 2 then removed her gloves and applied new glove without performing hand hygiene. 6. During an observation on 01/09/2025, beginning at 10:25 AM, PCT 2 entered station #17 with Patient #18, due to the AVF removal site was bleeding, and touched Patient’s AVF site and then entered Station #14 with Patient #16 wearing the same gloves from station #17 and touched the supplies Patient #16’s chair tray. During the observation, the Clinical Manager spoke to PCT 2, PCT 2 then removed her gloves and applied new gloves without performing hand hygiene, PCT 2 entered station #14 with Patient #16 and applied a new gauze to the AVF site, a red substance was visible on the barrier under the AVF and the barrier was disposed of in the garbage, PCT 2 removed her gloves, applied new gloves without performing hand hygiene and returned to station #14. 7. During an observation on 01/09/2025, beginning at 10:30 AM, PCT 2 was at station #16 with Patient #31, disconnected Patient’s left central venous catheter [CVC](catheter into large vein), PCT 2 removed her gloves, applied new gloves without performing hand hygiene and then escorted Patient #31 to the scale, PCT 2 touched the scale buttons with gloves on, returned to station #16 and touched the computer keyboard without changing gloves. 8. During an observation on 01/09/2025, beginning at 11:00 AM, PCT 3 cleaned station #18’s HD machine and bucket was emptied into the dirty sink, PCT 3 then removed her gloves, applied new gloves without performing hand hygiene, entered station #18 and cleaned the blood pressure cuff and chair. 9. During an observation on 01/09/2025, beginning at 12:45 PM, PCT 2 was at station #14 typing on the keyboard with gloves on, wearing the same gloves PCT 2 then went to the scale to weigh Patient #17, PCT 2 then returned to station #15 with Patient #17 and typed on the keyboard without changing gloves. 10. During an interview on 01/09/2025, beginning at 10:45 AM, PCT 2 indicated hands should be cleaned with hand sanitizer between each patient and station and after each glove change.”

    Rule V0113. Standard-level.

  • Ic - Hbv - Vaccinate Patients & Staff

    The inspectors’ words, 672 words

    “IC-HBV-VACCINATE PTS/STAFF CFR(s): 494.30(a)(1)(i) Hepatitis B Vaccination Vaccinate all susceptible patients and staff members against hepatitis B. This Standard is not met as evidenced by: 47022 Based on record review and interview, the dialysis facility failed to ensure 27% of qualified patients susceptible to Hepatitis B (liver infection) were offered the Hepatitis B vaccine in 1 of 1 agency (Patient #1, 5, 6, 9, 18, 32, and 35). Findings include: 1. A policy dated 02/07/2022, titled, “Patient Vaccination for Hepatitis B,” indicated a patient with a Hepatitis B anti-HB (antibody to Hepatitis B) level less than 10 (susceptible to Hepatitis B) and had a reported previous vaccination the patient should be vaccinated, and if a patient had a previous Hepatitis B anti-HB level greater than or equal to 10 and the level falls below 10 the physician should be notified to discuss administration of a Hepatitis B booster dose. 2. An Infection Surveillance Platform, dated 01/13/2025, indicated 63% of patients were immune to Hepatitis B, 33% of patients were susceptible to Hepatitis B, and 1% of susceptible patients had a valid excuse. 3. An undated Patient Detail Report for Hepatitis B, received on 01/10/2025, indicated of the 26 patients that were susceptible to Hepatitis B, 42% of patients were in the process of receiving the Hepatitis B vaccine series, 12% patients refused, 4% of patients did not qualify due to a diagnosis of acute kidney injury, 8% of patients were non-responders to the vaccine, 8% patients had the Hepatitis B antibody checked after 12/22/2024, and 27% of patients that qualified for the Hepatitis B vaccine were not offered the Hepatitis B vaccine. 4. An undated Patient Detail Report for Hepatitis B indicated Patient #1 had a Hepatitis B surface antibody result (anti-HB) less than 10 on 10/24/2024 and failed to evidence a reason Patient was not offered a Hepatitis B vaccine. 5. An undated Patient Detail Report for Hepatitis B indicated Patient #5 had a Hepatitis B anti-HB less than 10 on 10/22/2024 and failed to evidence a reason Patient was not offered a Hepatitis B vaccine. 6. An undated Patient Detail Report for Hepatitis B indicated Patient #6 had a Hepatitis B anti-HB less than 10 on 10/17/2024 and failed to evidence a reason Patient was not offered a Hepatitis B vaccine. 7. An undated Patient Detail Report for Hepatitis B indicated Patient #9 had a Hepatitis B anti-HB less than 10 on 05/14/2024 and failed to evidence a reason Patient was not offered a Hepatitis B vaccine. 8. An undated Patient Detail Report for Hepatitis B indicated Patient #18 had a Hepatitis B anti-HB less than 10 on 05/14/2024 and failed to evidence a reason Patient was not offered a Hepatitis B vaccine. 9. An undated Patient Detail Report for Hepatitis B indicated Patient #32 had a Hepatitis B anti-HB less than 10 on 11/22/2024 and failed to evidence a reason Patient was not offered a Hepatitis B vaccine. 10. An undated Patient Detail Report for Hepatitis B indicated Patient #34 had a Hepatitis B anti-HB less than 10 on 05/13/2024 and failed to evidence a reason Patient was not offered a Hepatitis B vaccine. 11. During an interview on 01/10/2025, the Clinical Manager (Administration Person 2) indicated Patient #1, Patient #9, Patient #32, and Patient #34 should have been offered the Hepatitis B vaccine and was not offered the vaccine, Patient #5 should have been offered the Hepatitis B vaccine and was not offered the vaccine due to Patient could not consent for it by themselves and the dialysis facility would need to reach out to a family member to consent due to Patient resided in a skilled nursing facility, Patient #6 should have been offered the Hepatitis B vaccine and was not offered the vaccine due to Patient was noncompliant with treatments, and Patient #18 should have been offered the Hepatitis B vaccine and was not offered the vaccine due to was a Spanish speaking patient and would need to be offered Patient Hepatitis B information in Spanish.”

    Rule V0126. Standard-level.

  • Ic - Catheters; General

    The inspectors’ words, 487 words

    “IC-CATHETERS:GENERAL CFR(s): 494.30(c)(2) (2) The “Guidelines for the Prevention of Intravascular Catheter-Related Infections” entitled “Recommendations for Placement of Intravascular Catheters in Adults and Children” parts I - IV; and “Central Venous Catheters, Including PICCs, Hemodialysis, and Pulmonary Artery Catheters in Adult and Pediatric Patients,” Morbidity and Mortality Weekly Report, volume 51 number RR-10, pages 16 through 18, August 9, 2002. The Director of the Federal Register approves this incorporation by reference in accordance with 5 U.S.C. 552(a) and 1 CFR Part 51. This publication is available for inspection as the CMS Information Resource Center, 7500 Security Boulevard, Central Building, Baltimore, MD or at the National Archives and Records Administration (NARA). Copies may be obtained at the CMS Information Resource Center. For information on the availability of this material at NARA, call 202-741-6030, or go to: http://www.archives.gov/federal_register/code_of_regulations/ibr_locations.html This Standard is not met as evidenced by: 47022 Based on observation, record review, and interview, the dialysis facility failed to ensure central venous catheter [CVC](catheter into large vein) standard infection control precautions were implemented by PCT 2 to prevent catheter related infections in 1 of 2 CVC initiations observed (Patient #1). Findings include: A Center for Disease Control website CDC.gov, titled, “Hemodialysis Central Venous Catheter,” indicated a CVC should be disinfected with an antiseptic pad for each hub(end of catheter access), the threads (sides of the hub) should be scrubbed thoroughly to remove any residue, and an antiseptic pad should be used to clean the limbs (catheter lines) at least several centimeters towards the body. A policy dated 05/06/2024, titled, “Initiation of Treatment Using a Central Venous Catheter (CVC) ....” indicated catheter threads and ends of the hub must be scrubbed with 70% alcohol for 10-15 seconds any time caps are removed, use a 70% alcohol pad to remove any exude on the limbs, and use an alcohol pad to clean from the hub at least several centimeters towards the body of the catheter and then attach a sterile syringe. During an observation on 01/09/2025, beginning at 11:45 AM, PCT 2 was observed at station #14 initiating access of Patient #1’s CVC. During the observation, PCT 2 removed the CVC’s hub caps on 2 lines and cleaned the 1st hub with an alcohol pad for 5 seconds; then she cleaned the 2nd hub with an alcohol pad for 3 seconds and inserted syringes into the hub. PCT 2 failed to clean the 1st or 2nd lines of the CVC, prior to insertion of the syringes, per policy and infection prevention standards of care. During an interview on 01/09/2025, beginning at 12:50 PM, PCT 2 indicated CVC hubs should be cleaned with an alcohol pad for 1 minute prior to insertion of syringes. During an interview on 01/10/2025, beginning at 3:00 PM, the Clinical Manager (Administration Person 2), indicated CVC site care would include cleaning the hub for 30 seconds with alcohol and the threads of the CVC should be cleaned.”

    Rule V0146. Standard-level.

  • Dialysis Access Type & Maintenance

    The inspectors’ words, 429 words

    “PA-DIALYSIS ACCESS TYPE & MAINTENANCE CFR(s): 494.80(a)(8) The patient’s comprehensive assessment must include, but is not limited to, the following: (8) Evaluation of dialysis access type and maintenance (for example, arteriovenous fistulas, arteriovenous grafts and peritoneal catheters). This Standard is not met as evidenced by: 47022 Based on observation, record review, and interview, the dialysis facility failed to ensure cannulations (insertion of needles) of arteriovenous fistula [AVF] (access for hemodialysis) [a process to filter the blood of a patient whose kidneys do not work normally] and arteriovenous graft [AVG] (access for hemodialysis) were completed by PCT 1 and PCT 2 to prevent AVF/AVG site infections in 4 of 4 AVF/AVG cannulations observed (Patient #8, #20, #23, and #30). Findings include: 1. A Center for Disease Control website CDC.gov titled, “AV Fistula, Graft Cannulation Observations,” indicated the AVF/AVG site should not be contacted after antiseptic was applied. 2. During an observation on 01/09/2025, beginning at 11:00 AM, PCT 2 was cannulating Patient #20’s right upper arm AVF at station #13, PCT 2 cleansed the AVF site with an alcohol prep pad and cannulated with the first line; she then recleaned with an alcohol prep pad, repalpated (touched) the site, and then cannulated the second line without recleaning the access site. 3. During an observation on 01/09/2025 beginning at 12:20 PM, PCT 2 was cannulating Patient #23’s left arm AVF at station #16; PCT 2 cleaned the AVF site with an alcohol prep pad and therepalpated the insertion site prior to cannulating the first line. PCT 2 then repalpated the insertion site, prior to cannulating the second line. 4. During an interview on 01/09/2025, beginning at 12:50 PM, PCT 2 indicated an AVF/AVG site should not be repalpated after the insertion site was cleansed with alcohol. 51199 5. During an observation on 01/09/2025, beginning at 10:53 a.m., observed PCT 1 cannulating Patient #8’s AVF at station #8; PCT 1 cleaned the AVF site with an alcohol prep pad and repalpated the insertion site, prior to cannulating the first line without recleaning the insertion site. PCT 1 then repalpated the insertion site prior to cannulating the second line without recleasing the insertion site before cannulation. 6. During an observation on 01/09/2025, beginning at 12:30 p.m., PCT 1 was cannulating Patient #30’s AVF at station #6. PCT 1 cleaned the AVF site with an alcohol prep pad and then repalpated the insertion site, prior to cannulating the first line. PCT 1 then repalpated the insertion site prior to cannulating the second line. PCT 1 did not reclean the insertion sites prior to cannulation.”

    Rule V0511. Standard-level.

  • Manage Volume Status

    The inspectors’ words, 260 words

    “POC-MANAGE VOLUME STATUS CFR(s): 494.90(a)(1) The plan of care must address, but not be limited to, the following: (1) Dose of dialysis. The interdisciplinary team must provide the necessary care and services to manage the patient’s volume status; This Standard is not met as evidenced by: 47022 Based on observation, record review, and interview, the dialysis facility failed to ensure PCT 6 administered the correct hemodialysis [HD] (a process to clean the blood of a patient whose kidneys do not work normally) prescription in 1of 5 active in-center hemodialysis prescriptions reviewed with the Clinical Manager, while on the observation floor (Patient #24). Findings include: A job description dated 07/12/2022, titled, “PCT 1,” indicated the PCT was responsible for the setup and operation of the HD machine. The job description indicated the PCT responsibilities would include initiate dialysis treatment according to the prescribed orders. During an observation on 01/09/2025, beginning at 11:22 AM, Patient #24, at Station #9 was receiving HD dialysate 2.0 K (potassium) 2.5 Ca (calcium). The elctronic medical record revealed the most recent prescription was dated 12/04/2024, Patient #24’s prescription for dialysate was 3.0 K 2.5 Ca. A Treatment Sheet dated 01/10/2025, indicated PCT 6 performed the machine set up and the HD was initiated by PCT 6. During an interview on 01/09/2025, beginning at 11:22 AM, the Clinical Manager (Administration Person 2) indicated Patient was receiving the incorrect HD dialysate. During an interview on 01/09/2025, beginning at 11:22 AM, PCT 6 indicated the HD prescription dialysate set up was incorrect and Patient received the incorrect dialysate bath.”

    Rule V0543. Standard-level.

  • Medical Records - Complete, Accurate, Accessible

    The inspectors’ words, 389 words

    “MR-COMPLETE, ACCURATE, ACCESSIBLE CFR(s): 494.170 The dialysis facility must maintain complete, accurate, and accessible records on all patients, including home patients who elect to receive dialysis supplies and equipment from a supplier that is not a provider of ESRD services and all other home dialysis patients whose care is under the supervision of the facility. This Standard is not met as evidenced by: 47022 Based on record review and interview, the dialysis facility failed to ensure the treatment records were complete and accurate in 4 of 8 active in-center hemodialysis [HD](a process to filter the blood of a patient whose kidneys do not work normally) patients clinical records reviewed (Patient #4, 5, 7, 8). Findings include: 1. A PCT job description dated, 07/12/2022, indicated the responsibilities for a PCT would include but not limited to initiating HD according to the prescribed orders including the blood flow rate [BFR] and DFR [dialysate flow rate], and record accurate documentation of information related to the patients’ treatment on the hemodialysis treatment sheet. 2. A Treatment Sheet, dated 01/09/2025, indicated Patient #4’s HD treatment began at 1:24 PM; the record failed to evidence the BFR and DFR were documented from 3:00 PM until the end of treatment at 4:33 PM. 3. A Treatment Sheet, dated 01/07/2025, indicated Patient #5’s HD treatment was initiated at 12:53 PM; the record failed to evidence the BFR and DFR were documented from 1:36 PM until the end of treatment at 3:57 PM. 4. A Treatment Sheet dated 01/04/2025, indicated Patient #7’s HD treatment was initiated at 7:08 AM; the record failed to evidence the BFR and DFR were documented from 9:32 AM until the end of treatment at 11:06 AM. 5. A Treatment Sheet dated 01/09/2025, indicated Patient #8’s HD treatment was initiated at 11:13 AM; the record failed to evidence the BFR and DFR were documented from 11:13 AM until the end of treatment at 2:37 PM. 6. During an interview on 01/13/2025, beginning at 11:40 AM, the Clinical Manager (Administration Person 2) indicated that the DFR and BFR should be documented by PCT’s manually if the HD machine fails to sync with the documentation system. The Clinical Manager indicated the BFR and DFR for Patient #4, Patient #5, Patient #7, and Patient #8 were not documented correctly and should have been documented by the PCT.”

    Rule V0726. Standard-level.

The one inspection in the last three years
Inspections on record
DateVisitWhat the record says
Jan 13, 2025Standard inspection6 deficiencies cited

Is it certified?

  • Medicare-certified dialysis facility, certified or last recertified on Feb 2, 2000.
  • Run for profit.
  • No deficiency on record in the last three years.
  • Chain: Fresenius Medical Care.
Source:

CMS, Dialysis Facility - Listing by Facility. Released Jul 15, 2026. Updated quarterly.

CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.

Has it been penalized?

  • CMS doesn’t publish fines or other penalties for dialysis facilities.
  • None of the deficiencies cited in the last three years came from an inspection that included a complaint investigation.
Source:

CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.

What does it offer?

  • Offers in-center hemodialysis.
  • Doesn’t offer peritoneal dialysis, home hemodialysis training and a shift starting at 5 p.m. or later.
  • 25 dialysis stations.
  • CMS doesn’t publish staffing levels for dialysis facilities.
Source:

CMS, Dialysis Facility - Listing by Facility and Patient survey (ICH CAHPS) - Facility. Released Jul 15, 2026. Updated quarterly.

Who owns it?

  • Part of the Fresenius Medical Care chain, as CMS lists it.
  • CMS publishes no owners file for dialysis facilities, so no other owner is named.
Source:

CMS, Dialysis Facility - Listing by Facility. Released Jul 15, 2026. Updated quarterly.

How do patients fare?

  • CMS rates it 2 of 5 stars (Jan 1, 2021 to Dec 31, 2024).
  • Compared by CMS with what it expects for the facility’s patients: patient survival, as expected; hospital admissions, as expected; readmissions to hospital, as expected; blood transfusions, as expected; emergency department visits, as expected; emergency department visits within 30 days of a hospital stay, as expected; bloodstream infections, better than expected; patients dialysing through a fistula, as expected; patients put on a kidney transplant waitlist in their first year of dialysis, as expected; patients on a kidney transplant waitlist, as expected.
  • CMS gives no : “Too few completed survey responses to report.”
Source:

CMS, Dialysis Facility - Listing by Facility and Patient survey (ICH CAHPS) - Facility. Released Jul 15, 2026. Updated quarterly.

Ratings and measures, as published
MeasureRating
Star ratingCMS’s star rating for dialysis facilities, 1 to 52 of 5
Patient survey ratingCMS star rating from its survey of the facility’s in-center hemodialysis patients (ICH CAHPS), 1 to 5Not rated

How does it compare nearby?

  • Of the 21 dialysis facilities CMS lists in Lake County, 19 have a star rating from CMS: 2 rated 5 of 5, 2 rated 4 of 5, 6 rated 3 of 5, 6 rated 2 of 5, 3 rated 1 of 5.
  • CMS rates this one 2 of 5.
Source:

CMS, Dialysis Facility - Listing by Facility. Released Jul 15, 2026. Updated quarterly.

What the record doesn’t say

  • CMS doesn’t publish fines or other penalties for dialysis facilities, so none are shown.
  • Only complaints that led to a citation appear; complaints that didn’t aren’t published.
  • QCOR says it has no dialysis inspection reports after February 19, 2026, while it moves to a new system: a later inspection is not shown yet.
  • CMS doesn’t publish staffing levels for dialysis facilities.
  • CMS publishes no owners file for dialysis facilities: the chain it lists is the only owner named.

Sources

If you believe something here is wrong, a correction starts with the agency whose record this copies: CMS. CMS’s own record is on Care Compare. If Hearth Record copied something wrongly, it will fix it and log the correction publicly, with its date: how corrections work.

Source:

This copy of the record was made on Oct 30, 2026.

From the facility

The public record above comes first. Anything the facility adds will appear here, below it, and say who wrote it.

Replies

None. Replies aren’t open yet. When they open, the facility will be able to answer any finding for free, and the reply will show beside that finding, unedited and dated.

Paid listing

None. Paid listings aren’t open yet. When they open, anything paid for will say “Paid by the facility”, and paying will never change a finding, a rating or the order of results.

How to read a record

Four things every record does, shown on an example record made up for this guide.

An example record, made up for this guide

An example nursing home

Made up for this guide: no real place is shown

Not fully inspected in over two years (CMS flag)

11 health citations at the latest inspection cycle

The state average is 14.3.

Source:

CMS, State and US Averages and Health Deficiencies. Released Oct 28, 2026. Updated monthly.

From the homeNone yet. Replies and paid listings aren’t open, and when they open they will sit here, below the record.

1 of 4

Every fact names its source.

Who published it, when, and how often it changes sit beside each fact, with a link to the agency’s own file.

Sign in

A free account keeps your watch list, shortlists, comparisons and saved searches on every device, and can email you when something you watch changes. Browsing never needs one.