Davita Crystal Springs Dialysis
A dialysis facility in Crystal Lake, Illinois 60014
720 Cog Circle, Ste A, Crystal Lake, Illinois 60014. (815) 459-4945.
Watch and the shortlist are kept with a free account, on every device. Your watch list. CMS’s own record is on Care Compare.
The short answer
Record last released by CMS on Oct 28, 2026.
- 3of 5 CMS’s star rating
- Not rated patient survey rating
- 4 deficiencies cited in the last three years
- 16 dialysis stations
Each figure’s source sits beside it, in its section below.
What these words mean3
- Star ratings
- CMS rates some kinds of place from 1 to 5 stars, more stars meaning better on CMS’s own measures for that kind: for a nursing home, its health inspections, staffing and quality measures. A rating is CMS’s summary of those measures; it doesn’t promise good care. Source: CMS, Care Compare and the Five-Star Quality Rating System.
- Inspection (survey)
- A visit by state inspectors, often unannounced, who check a place against the rules it must meet. For nursing homes and other places Medicare pays, CMS calls these visits surveys: a standard survey of a nursing home comes at least every 15 months, and a complaint survey whenever a complaint calls for one. Source: CMS; 42 CFR 488.308.
- Deficiency, citation, violation
- What inspectors write up when a place didn’t meet a rule: the rule, what they saw, and when. CMS calls it a deficiency; states may say citation or violation. It is the inspectors’ finding, not a court’s, and the place is usually asked for a plan to correct it. Source: CMS, statement of deficiencies (Form CMS-2567); each state’s licensing agency.
What did inspectors find?
The last inspection on record was on Jul 30, 2025: a complaint inspection.
4 deficiencies cited in the last three years.
CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.
When those deficiencies happened
4 deficiencies in 1 month of the last 36. Last cited Jul 2025. Most serious: Standard-level. The last 3 years, to Oct 30, 2026.
| Jan | Feb | Mar | Apr | May | Jun | Jul | Aug | Sep | Oct | Nov | Dec | |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 2023 | Nov | Dec | ||||||||||
| 2024 | Jan | Feb | Mar | Apr | May | Jun | Jul | Aug | Sep | Oct | Nov | Dec |
| 2025 | Jan | Feb | Mar | Apr | May | Jun | Jul | Aug | Sep | Oct | Nov | Dec |
| 2026 | Jan | Feb | Mar | Apr | May | Jun | Jul | Aug | Sep | Oct |
Hover or focus a month to read it.
Hearth Record drew this from the dates and levels in the source’s own records.
Each deficiency, as cited
Rule titles as CMS’s inspectors cite them, set in sentence case.
CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.
Jul 30, 2025: standard inspection4 deficiencies
-
Ic - Wear Gloves/Hand Hygiene
The inspectors’ words, 240 words
“IC-WEAR GLOVES/HAND HYGIENE CFR(s): 494.30(a)(1) Wear disposable gloves when caring for the patient or touching the patient’s equipment at the dialysis station. Staff must remove gloves and wash hands between each patient or station. This Standard is not met as evidenced by: 52901 Based on document review, observation and interview, for 1 of 1 (E#1/Patient Care Technician), staff observed performing exit site care of a CVC (central venous catheter) for Pt#5, the facility failed to ensure that staff changed gloves and performed hand hygiene as required per policy. Findings include: 1. The facility’s policy titled, “Central Venous Catheter (CVC) with Tego Connectors or CVC Caps Care Procedure (October 2024)” was reviewed on 07/28/2025 and required, “Remove old dressing and discard ... Remove gloves and discard. Perform hand hygiene per procedure and re-glove. Place sterile 2 x 2 gauze over the catheter exit site” 2. On 07/28/2025 from 9:45 AM to 11:30 AM, during an observational tour of the treatment floor, the following was observed: -At 11:00 AM, E #1 was changing the CVC dressing for Pt. #5. E #1 had gloves on and removed Pt. #5 dressing and proceeded to clean the CVC site and place a new dressing. E #1 did not change gloves or perform hand hygiene between tasks. 3. At approximately 11:10 AM, an interview with E #1 was conducted. E#1 stated, “I was under pressure and should have changed my gloves after removing the dirty dressing.””
-
Ic - Training And Education
The inspectors’ words, 270 words
“IC-TRAINING & EDUCATION CFR(s): 494.30(a)(1)(i) Infection Control Training and Education Infection control practices for hemodialysis units: intensive efforts must be made to educate new staff members and reeducate existing staff members regarding these practices. This Standard is not met as evidenced by: 48264 Based on documentation review, observation and interview, for 1 of 1 (E#2/Patient Care Technician) staff observed cannulating an arteriovenous fistula (AVF, dialysis access), the facility failed to ensure that staff did not touch the site after prepping the site, potentially causing contamination. Findings included: 1. The facility’s policy titled, “AV Fistula or Graft Cannulation with JMS Sysloc Mini Safety Needles (SFN/accessing equipment of dialysis/removal of toxins and excess fluid from blood) and Administration of Heparin (medication to prevent blood clots) Loading (increased dose of medication at the beginning of a course of treatment) Dose” (April 2025) was reviewed on 7/28/2025 and included, “ ...Procedure: ...13. Do not palpate insertion site once area has been prepped ...Rationale: Once the access site has been prepped, touching it will contaminate the site and possibly allow for the introduction of bacteria during cannulation ...”. 2. During an observational tour of Dialysis unit on 07/28/2025 from 9:45 AM to 11:30 AM, the following was observed: -At approximately 10:15 AM, E#2 was observed prepping the dialysis site for a patient at station #12. E#2 cleansed the insertion site, E#2 then palpated insertion site and then cannulated the site, without re-prepping insertion site. 3. An interview was conducted with E #2 on 7/28/2025 at approximately 10:45 AM. E#2 stated that the access site should not have been touched after being prepped to prevent infection.”
-
Assess B/P & Fluid Management Needs
The inspectors’ words, 402 words
“PA-ASSESS B/P, FLUID MANAGEMENT NEEDS CFR(s): 494.80(a)(2) The patient’s comprehensive assessment must include, but is not limited to, the following: Blood pressure, and fluid management needs. This Standard is not met as evidenced by: 27125 Based on document review and interview, for 3 of 5 (Pt. #1, Pt. #4,and Pt. #5) in center hemodialysis records reviewed, the facility failed to ensure that vital signs (blood pressure/pulse) were taken every 30 minutes while receiving dialysis treatments. Findings included: 1. The Facility’s policy titled, “Pre [before]-Intra [during]-Post [after] Treatment Data Collection, monitoring and nursing assessment (April 2024)” was reviewed and included, “Purpose: To obtain and document baseline and ongoing information about the patient. ... This information will be used in planning and documenting the patient’s dialysis treatment ... for reviewing the patient’s response to treatment and status prior to discharge. ... Intradialytic treatment monitoring and data collection ... includes: vital signs ... Non -Nocturnal [not at night] treatments are completed at least every thirty minutes. 2. The clinical record of Pt. #1 was reviewed on 7/29/2025. Pt. #1 was admitted on 3/24/2025 with the diagnosis of end stage renal disease (ESRD). The following treatment sheets included missed thirty minute vital signs during treatment: - 7/16/2025 - vital signs taken at 4:34 PM and again at 5:34 PM (60 minutes). - 7/26/2025 - vital signs taken at 11:04 AM and again at 12:04 PM (60 minutes). 3. The clinical record of Pt. #4 was reviewed on 7/29/2025. Pt. #4 was admitted on 7/13/2018 with a diagnosis of ESRD. The following treatment sheets included missed thirty minute vital signs during treatment: - 7/17/2025 - vital signs taken at 9:39 AM and again at 10:39 AM (60 minutes). - 7/18/2025 - vital signs taken at 7:07 AM and again at 8:07 AM (60 minutes). - 7/21/2025 - vital signs taken at 8:33 AM and again at 9:33 AM (60 minutes). 4. The clinical record of Pt. #5 was reviewed on 7/29/2025. Pt. #5 was admitted on 11/13/2019 with a diagnosis of ESRD. The following treatment sheet included missed thirty minute vital signs during treatment: - 7/16/2025 - vital signs taken at 11:53 AM and again at 1:14 PM (81 minutes). 5. During an interview on 7/30/2025 at 9:00 AM, the Facility Administrator (E#3) stated that vital signs need to be taken and documented every 30 minutes during dialysis treatment to assess how the patient is tolerating treatment.”
-
Patients Seen By Med Staff Member Monthly
The inspectors’ words, 233 words
“POC-PTS SEEN BY MED STAFF 1X/MO CFR(s): 494.90(b)(4) The dialysis facility must ensure that all dialysis patients are seen by a physician, nurse practitioner, clinical nurse specialist or physician’s assistant providing ESRD care at least monthly, as evidenced by a monthly progress note placed in the medical record, and periodically while the hemodialysis patient is receiving in-facility dialysis. This Standard is not met as evidenced by: 27125 Based on document review and interview, 1 of 5 (Pt. #5) in center hemodialysis records reviewed, the facility failed to ensure that each patient was seen by the attending nephrologist (kidney doctor) at least once a month. Findings include: 1. The facility’s policy titled, “Progress note policy (October 2024)” was reviewed on 7/29/2025 and required, “Progress notes are completed to verify documentation of patient’s problems/needs, interventions, and response to intervention. ... The attending nephrologist is required to record notes at least monthly ... and provides other interdisciplinary team members with an up-to-date status of the patient at all times.” 2. The clinical record of Pt. #5 was reviewed on 7/29/2025. Pt. #5 was admitted on 11/13/2019 with a diagnosis of end stage renal disease. Physician progress notes included 4/21/2025 and 7/9/2025 (missing May and June 2025). 3. During an interview on 7/30/2025 at 9:00 AM, the Facility Administrator (E#3) stated, “ The physician is supposed to see every patient and document a progress note every month.””
All 2 inspections in the last three years
| Date | Visit | What the record says |
|---|---|---|
| Jul 30, 2025 | Complaint inspection | No deficiencies cited |
| Jul 30, 2025 | Standard inspection | 4 deficiencies cited |
Is it certified?
- Medicare-certified dialysis facility, certified or last recertified on Jul 1, 2010.
- Run for profit.
- No For hospices, home health agencies, hospitals and dialysis facilities, CMS writes deficiencies at two levels. Standard is the usual one; condition-level is the more serious, when a problem is serious enough that the provider doesn’t meet a whole condition of taking part in Medicare. Source: CMS, State Operations Manual. deficiency on record in the last three years.
- Chain: DaVita.
CMS, Dialysis Facility - Listing by Facility. Released Jul 15, 2026. Updated quarterly.
CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.
Has it been penalized?
- CMS doesn’t publish fines or other penalties for dialysis facilities.
- None of the deficiencies cited in the last three years came from an inspection that included a complaint investigation.
CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.
What does it offer?
- Offers in-center hemodialysis.
- Doesn’t offer peritoneal dialysis, home hemodialysis training and a shift starting at 5 p.m. or later.
- 16 dialysis stations.
- CMS doesn’t publish staffing levels for dialysis facilities.
CMS, Dialysis Facility - Listing by Facility and Patient survey (ICH CAHPS) - Facility. Released Jul 15, 2026. Updated quarterly.
Who owns it?
- Part of the DaVita chain, as CMS lists it.
- CMS publishes no owners file for dialysis facilities, so no other owner is named.
CMS, Dialysis Facility - Listing by Facility. Released Jul 15, 2026. Updated quarterly.
How do patients fare?
- CMS rates it 3 of 5 stars (Jan 1, 2021 to Dec 31, 2024).
- Compared by CMS with what it expects for the facility’s patients: patient survival, as expected; hospital admissions, as expected; readmissions to hospital, as expected; blood transfusions, as expected; emergency department visits, as expected; emergency department visits within 30 days of a hospital stay, as expected; bloodstream infections, as expected; patients dialysing through a fistula, as expected; patients on a kidney transplant waitlist, as expected.
- CMS gives no CMS rates some kinds of place from 1 to 5 stars, more stars meaning better on CMS’s own measures for that kind: for a nursing home, its health inspections, staffing and quality measures. A rating is CMS’s summary of those measures; it doesn’t promise good care. Source: CMS, Care Compare and the Five-Star Quality Rating System.: “Too few completed survey responses to report.”
CMS, Dialysis Facility - Listing by Facility and Patient survey (ICH CAHPS) - Facility. Released Jul 15, 2026. Updated quarterly.
| Measure | Rating |
|---|---|
| Star ratingCMS’s star rating for dialysis facilities, 1 to 5 | 3 of 5 |
| Patient survey ratingCMS star rating from its survey of the facility’s in-center hemodialysis patients (ICH CAHPS), 1 to 5 | Not rated |
How does it compare nearby?
- Of the 8 dialysis facilities CMS lists in McHenry County, 7 have a star rating from CMS: 1 rated 5 of 5, 1 rated 4 of 5, 4 rated 3 of 5, 1 rated 2 of 5.
- CMS rates this one 3 of 5.
CMS, Dialysis Facility - Listing by Facility. Released Jul 15, 2026. Updated quarterly.
What the record doesn’t say
- CMS doesn’t publish fines or other penalties for dialysis facilities, so none are shown.
- Only complaints that led to a citation appear; complaints that didn’t aren’t published.
- QCOR says it has no dialysis inspection reports after February 19, 2026, while it moves to a new system: a later inspection is not shown yet.
- CMS doesn’t publish staffing levels for dialysis facilities.
- CMS publishes no owners file for dialysis facilities: the chain it lists is the only owner named.
Sources
-
Centers for Medicare & Medicaid Services, Dialysis Facility - Listing by Facility (23ew-n7w9).
Released Jul 15, 2026 and checked Oct 30, 2026. Updated quarterly. Public domain (U.S. Government work).
-
Centers for Medicare & Medicaid Services, Patient survey (ICH CAHPS) - Facility (59mq-zhts).
Released Jul 15, 2026 and checked Oct 30, 2026. Updated quarterly. Public domain (U.S. Government work).
-
Centers for Medicare & Medicaid Services, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies (ESRD_2567s_2018_to_2026YTD.xlsx).
Released Oct 28, 2026 and checked Oct 30, 2026. Updated monthly. Public domain (U.S. Government work).
If you believe something here is wrong, a correction starts with the agency whose record this copies: CMS. CMS’s own record is on Care Compare. If Hearth Record copied something wrongly, it will fix it and log the correction publicly, with its date: how corrections work.
This copy of the record was made on Oct 30, 2026.
From the facility
The public record above comes first. Anything the facility adds will appear here, below it, and say who wrote it.
Replies
None. Replies aren’t open yet. When they open, the facility will be able to answer any finding for free, and the reply will show beside that finding, unedited and dated.
Paid listing
None. Paid listings aren’t open yet. When they open, anything paid for will say “Paid by the facility”, and paying will never change a finding, a rating or the order of results.