Davita Windsor Heights Dialysis
A dialysis facility in Windsor Heights, Iowa 50324
1119 73rd St, Windsor Heights, Iowa 50324. (515) 274-9303.
Watch and the shortlist are kept with a free account, on every device. Your watch list. CMS’s own record is on Care Compare.
The short answer
Record last released by CMS on Oct 28, 2026. We couldn’t read Centers for Medicare & Medicaid Services’ list since Nov 2, 2026: qcor.cms.gov now refuses our reader. This record is as of then.
- 3of 5 CMS’s star rating
- Not rated patient survey rating
- 7 deficiencies cited in the last three years
- 12 dialysis stations
Each figure’s source sits beside it, in its section below.
What these words mean3
- Star ratings
- CMS rates some kinds of place from 1 to 5 stars, more stars meaning better on CMS’s own measures for that kind: for a nursing home, its health inspections, staffing and quality measures. A rating is CMS’s summary of those measures; it doesn’t promise good care. Source: CMS, Care Compare and the Five-Star Quality Rating System.
- Inspection (survey)
- A visit by state inspectors, often unannounced, who check a place against the rules it must meet. For nursing homes and other places Medicare pays, CMS calls these visits surveys: a standard survey of a nursing home comes at least every 15 months, and a complaint survey whenever a complaint calls for one. Source: CMS; 42 CFR 488.308.
- Deficiency, citation, violation
- What inspectors write up when a place didn’t meet a rule: the rule, what they saw, and when. CMS calls it a deficiency; states may say citation or violation. It is the inspectors’ finding, not a court’s, and the place is usually asked for a plan to correct it. Source: CMS, statement of deficiencies (Form CMS-2567); each state’s licensing agency.
What did inspectors find?
The last inspection on record was on May 21, 2025: a standard inspection.
7 deficiencies cited in the last three years.
CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.
When those deficiencies happened
7 deficiencies in 1 month of the last 36. Last cited May 2025. Most serious: Standard-level. The last 3 years, to Oct 30, 2026.
| Jan | Feb | Mar | Apr | May | Jun | Jul | Aug | Sep | Oct | Nov | Dec | |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 2023 | Nov | Dec | ||||||||||
| 2024 | Jan | Feb | Mar | Apr | May | Jun | Jul | Aug | Sep | Oct | Nov | Dec |
| 2025 | Jan | Feb | Mar | Apr | May | Jun | Jul | Aug | Sep | Oct | Nov | Dec |
| 2026 | Jan | Feb | Mar | Apr | May | Jun | Jul | Aug | Sep | Oct |
Hover or focus a month to read it.
Hearth Record drew this from the dates and levels in the source’s own records.
Each deficiency, as cited
Rule titles as CMS’s inspectors cite them, set in sentence case.
CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.
May 21, 2025: standard inspection7 deficiencies
-
Ic - Sanitary Environment
The inspectors’ words, 347 words
“IC-SANITARY ENVIRONMENT CFR(s): 494.30 The dialysis facility must provide and monitor a sanitary environment to minimize the transmission of infectious agents within and between the unit and any adjacent hospital or other public areas. This Standard is not met as evidenced by: 36083 Based on documents review, interviews, and observations, the facility did not ensure a safe and sanitary environment by its failure to discard multiple expired and outdated supplies, and an outdated tuberculin solution, from facility circulation, thereby creating a risk for usage. The facility reported a census of 65 patients at the time of the survey. Findings include: 1. The policy # 1-05-01, titled, Infection Control for Dialysis Facilities, provides for its purpose to minimize the spread of infections in the dialysis facility environment, and that supplies will be stored in a manner that maintains their integrity. 2. The manufacturer’s information sheet, titled, Tuberculin Purified Protein Derivative (Tubersol) dated October 2021, provides, “A vial of TUBERSOL which has been entered and in use for 30 days should be discarded.” 3. Observations on 5/19/25, beginning at 10:15 AM, showed the following: 12 intravenous (IV) infusion sets that expired on 3/9/25, found in the emergency evacuation luggage bag; 1 vial of Tubersol, dated as opened on 4/11/25, was stored in the medication refrigerator; 11 test strips in a container labeled, “RPC 4.5-10 PH test strips” with an expiration date of 2/28/25 was on the medication preparation counter; and approximately 50 sets of AVF (arteriovenous) G14 needles with expiration date of 4/30/25 and approximately 25 sets of AVF (arteriovenous) G14 needles with expiration date of 1/31/25, were stored in a plastic container in the supply storage area, readily accessible for staff members to get supplies from. 4. On 5/19/25 at 10:45 AM, registered nurse (RN) B stated, “Yes, those are clearly expired, and should have been tossed.” RN B verified that the medication and the supplies identified were expired. 5. On 5/21/25 at 2:00 PM, the facility administrator (FA) and the manager of clinical services (MCS) acknowledged the risk of usage for keeping expired supplies accessible for staff.”
-
Ic - Staff Education Re Catheters/Catheter Care
The inspectors’ words, 730 words
“IC-STAFF EDUCATION-CATHETERS/CATHETER CARE CFR(s): 494.30(a)(2) Recommendations for Placement of Intravascular Catheters in Adults and Children I. Health care worker education and training A. Educate health-care workers regarding the ... appropriate infection control measures to prevent intravascular catheter-related infections. B. Assess knowledge of and adherence to guidelines periodically for all persons who manage intravascular catheters. II. Surveillance A. Monitor the catheter sites visually of individual patients. If patients have tenderness at the insertion site, fever without obvious source, or other manifestations suggesting local or BSI [blood stream infection], the dressing should be removed to allow thorough examination of the site. Central Venous Catheters, Including PICCs, Hemodialysis, and Pulmonary Artery Catheters in Adult and Pediatric Patients. VI. Catheter and catheter-site care B. Antibiotic lock solutions: Do not routinely use antibiotic lock solutions to prevent CRBSI [catheter related blood stream infections]. This Standard is not met as evidenced by: 50072 Based on review of facility policies and procedures, observations and staff interviews, the facility staff failed to ensure staff properly disinfected the CVC (Central Venous Catheter) and site with antiseptic during site care according to facility policy. Failure to properly disinfect the patient’s skin prior to initiation of dialysis and failure to properly disinfect the CVC prior to initiation of dialysis treatment and during disconnect after dialysis could potentially cause cross contamination of the hemodialysis patients. The facility staff reported a census of 65 hemodialysis patients at the time of the recertification survey. Findings for observations on 3 of 3 patients with a Central Venous Catheter (CVC) access include: 1. Review of facility policy 1-04-02B, titled Central Venous Catheter (CVC) with Clearguard HD Antimicrobial End Caps Procedure, revised April 2025, reads in part: Notes: Perform a 15 second hub scrub of the CVC during the process of connecting or disconnecting from the blood lines ... 8 ...clean exit site with 2% Chlorhexidine Gluconate/70% Isopropyl Alcohol swab for a minimum of 30 seconds ...Effective contact time for 2% Chlorhexidine Gluconate/70% Isopropyl Alcohol is 30 seconds and dry time is 60 seconds. 16 ...Using aseptic technique, remove each cap. One at a time, disinfect each CVC hub with a new alcohol prep pad. Scrub each CVC hub for 15 seconds including the sides, threads and end of hub thoroughly with friction making sure to remove any residue ...34 ...Remove syringes and disinfect the CVC hubs with a new alcohol prep pad for each CVC hub. Scrub the sides, threads and end of hub thoroughly with friction for 15 seconds. 2. Observations on 05/19/25 at 11:50 am showed PCT (Patient Care Technician) C completing CVC exit site care on Patient #2. Observation showed PCT C used a ChloraPrep swab stick on the skin around the patient’s access for less than the amount of time specified in the facility’s written policy. PCT C cleaned the area around the CVC exit site with a ChloraPrep swab stick for 16 seconds, allowing for the appropriate drying time, before applying the dressing. Continued observation at 1:03 pm showed PCT C completing CVC exit site care on Patient #10. Observation showed PCT C used a ChloraPrep swab stick on the skin around the patient’s access for less than the amount of time specified in the facility’s written policy. PCT cleaned the area around the CVC exit site with a ChloraPrep swab stick for 15 seconds, allowing for the appropriate drying time, before applying the dressing. 3. An observation on 5/19/25 at 3:50 PM showed PCT H at station #12 completing catheter (CVC) exit site care (cleaning and changing the dressing) for Patient #9. PCT H cleaned or “scrubbed” the skin around Patient #9’s CVC with an antiseptic for 10 seconds. PCT H allowed the antiseptic to dry for 30 seconds before covering the area with a Tegaderm (a transparent medical dressing used to cover/protect catheter sites). 4. During an interview on 05/19/25 at 1:25 pm, PCT G reported the ChloraPrep swab stick scrub time is 30 seconds. PCT G acknowledged the posted signs on the treatment floor serve as a good reminder for staff because it does get confusing since scrub times are different for each product. 5. During an interview on 05/21/25 at 1:00 pm, the Medical Director acknowledged staff practices and verified staff should refer to the posted signs on the treatment floor regarding scrub times for each product because it is important with regards to infection control. 51639”
-
Ro - Meets Aami/Monitored, Recorded On Log
The inspectors’ words, 714 words
“RO-MEETS AAMI/MONITORED, RECORDED ON LOG CFR(s): 494.40(a) 5.2.7 Reverse osmosis: meets AAMI/monitored/recorded on log Refer to RD62:2001, 4.3.7 Reverse osmosis: When used to prepare water for hemodialysis applications, either alone or as the last stage in a purification cascade, reverse osmosis systems shall be shown to be capable, at installation, of meeting the requirements of Table 1, when tested with the typical feed water of the user, in accordance with the methods of [AAMI] 5.2.2. 5.2.7 Reverse osmosis Users should carefully follow the manufacturer’s instructions for feed water treatment and monitoring to ensure that the RO is operated within its design parameters. 6.2.7 Reverse osmosis All results of measurements of RO performance should be recorded daily in an operating log that permits trending and historical review. This Standard is not met as evidenced by: 50072 Based on documents review and staff interviews, the facility failed ensure the Biomedical Technician was notified when the water treatment system readings did not fall within specified limits. The facility reported a census of 65 patients at the time of survey who could potentially be adversely affected by the deficient practice. Findings include: 1. Review of Policy: 1-17-02, titled DAILY WATER TREATMENT SYSTEM MONITORING, last revised April 2025, reads in part that 2. All observations and test results must be recorded on the approved Daily Water Treatment Log and required IT Clinical System entries ... 6. All observations and test results will be within the limits specified on the Daily Water Treatment Log. If observations or test results are found outside the specified limits, follow the instructions given on the Daily Water Treatment Log for the parameter(s) in question. In addition to following the log form instructions, the teammate completing the log will notify the Facility Administrator/designee and Biomed teammate assigned to the facility of any observation or test result found outside the limit specified on the Daily Water Treatment Log ... 8. A licensed nurse reviews the Daily Water Treatment Log for completeness and verifies that all parameters are within specified limits. Upon satisfactory completion of this review, the licensed nurse initials and signs the log form where indicated. 2.Review of facility document titled “CWP Daily Water Log,” dated 03/03/05 - 05/17/25, shows: a. Line 19 read “Ultra Filter Inlet Pressure” with an acceptable limit of “>60psi (pounds per square inch); <100psi.” Entries outside of the acceptable limits were recorded on 03/05/25, 03/07/25, 03/24/25, 03/26/25, 03/31/25, 04/02/25, 04/04/25, 04/07/25, 04/09/25, 04/11/25, 04/28/25, 04/30/25, 05/02/25, 05/05-05/07/25; 05/10/25, and 05/12-05/17/25. Entries outside the acceptable limits ranged from 40-60 psi. b. Line 20 read “Ultra Filter Outlet Pressure” with an acceptable limit of “>60psi; <100psi.” Entries outside of the acceptable limits were recorded on 03/05/25, 03/07/25, 03/24/25, 03/26/25, 03/31/25, 04/02/25, 04/04/25, 04/07/25, 04/09/25, 04/11/25, 04/28/25, 04/30/25, 05/02/25, 05/05/25-05/07/25; 05/10/25, and 05/13/25-05/17/25. Entries outside the acceptable limits ranged from 40-60 psi. c. Line 24 read “If Required, Time when Biomed Contacted for Direction or Assistance.” Entries for line 27 is “NA” on all of the above dates recorded outside the acceptable limits. d. Line 25 reads “Initials of Licensed Nurse (Verifying that Log is Complete & Results are within Acceptable Limits). Line 25 is initialed on each date confirming the log was reviewed and the entries are within acceptable limits despite the values being outside the acceptable limits and no notification to the Biomedical Technician was recorded. 3. On 05/19/25 at 10:30 am, Staff F (Biomedical Technician) verified the information included in the CWP Daily Water Logs. Staff F confirmed they audit the water logs for completion and make adjustments based on trends. Staff F reported he/she expects to be notified of any readings outside the acceptable limits recorded on the water log, even if it’s a small variation. 4. On 05/20/25 at 11:30 am, PCT (Patient Care Technician) E confirmed if the entries on the log are outside the acceptable limits and reported staff are to advise Biomed of the results and document on the CWP Daily Water Log. 5. On 05/21/25 at 1:00 pm the Medical Director confirmed both the Biomedical Technician and the Facility Administrator are tasked with auditing the water logs for accuracy. The Medical Director further reported staff should be alerting the Biomedical Technician of any entries on the water log that are outside the acceptable limits.”
-
Appropriateness Of Dialysis Rx
The inspectors’ words, 486 words
“PA-APPROPRIATENESS OF DIALYSIS RX CFR(s): 494.80(a)(2) The patient’s comprehensive assessment must include, but is not limited to, the following: (2) Evaluation of the appropriateness of the dialysis prescription, This Standard is not met as evidenced by: 44475 Based on review of Facility Documents, Clinical Records, and staff interview, the facility failed to verify dialysis prescriptions after hospitalization and before dialysis treatment resumed for 2 of 2 patients reviewed for hospitalizations (Patients #1 and #2). The facility reported a census of 65 in center hemodialysis patients at the time of the survey. Findings include: The facility document titled “Transition of Care: Post-Hospitalization Checklist (All Modalities)”, undated, directed in part, to complete the steps below in order to help prevent readmissions. The RN (Registered Nurse) was to contact the nephrologist to review tx (treatment) orders/protocols and prescription changes. 1. The facility’s hospitalization report provided during the survey on 5/19/25, listed Patient #2 for hospital admission related to infection on 12/27/24. 2. The Patient Summary Report for Patient #1 revealed that the patient was hospitalized 3/21/25 to 3/30/25 and 4/18/25 to 4/24/25. 3. During a review of Patient #2’s Treatment Details Report, dated 1/1/25, indicated Patient #2’s return for treatment after a hospitalization. However, there was lack of any documentation to show that Patient #2’s dialysis prescription was reviewed after the hospitalization, and before resumption of dialysis treatment. 4. In a concurrent clinical record review and interview on 5/21/25 at 8:48 AM with Staff A, Manager of Clinical Services, no documentation was found in Patient #1’s clinical record that the patient ’ s dialysis treatment prescription was verified before dialysis treatment was resumed after the patient was hospitalized for the two hospitalizations. Staff A reported that dialysis treatment prescriptions should be reviewed after a patient was hospitalized and before dialysis treatment resumed. Staff A reported that the facility does not have a policy related to prescription verification after patients are hospitalized and before dialysis treatment resumed. 5. During interview on 5/21/25 at 9:00 AM, the facility administrator (FA) stated Patient #2 was hospitalized from 12/27/24 through 12/31/24, and had in-center dialysis treatment on 1/1/25. 6. In an interview on 5/21/25 at 10:23 AM, Staff B, RN, reported that she called the provider to verify prescription before resuming treatments for patients that were hospitalized. When asked where the verification was documented, Staff B reported that it should be in the patient ’ s clinical record, but that it does not always get documented. 7. In an interview on 5/21/25 at 1:12 PM, the Medical Director reported that there was a process in place to bridge continuity of care of the dialysis treatment order when patients are discharged from the hospital to ensure the order was given to the dialysis facility before the patient resumes treatment. The Medical Director reported that dialysis nurse verification of the dialysis prescription order before treatment resumes was a standard of practice for the facility. 36083”
-
Achieve Adequate Clearance
The inspectors’ words, 398 words
“POC-ACHIEVE ADEQUATE CLEARANCE CFR(s): 494.90(a)(1) Achieve and sustain the prescribed dose of dialysis to meet a hemodialysis Kt/V of at least 1.2 and a peritoneal dialysis weekly Kt/V of at least 1.7 or meet an alternative equivalent professionally-accepted clinical practice standard for adequacy of dialysis. This Standard is not met as evidenced by: 36083 Based on documents review, observation, and interviews, the facility did not ensure the correct dialysate for 1 of 4 patients (Patient #8) in the sample observed for dialysis prescription verification. The facility reported a census of 65 patients at the time of the survey. Findings include: 1. The policy #1-03-08, titled, Pre-Intra-Post Treatment Data Collection, Monitoring and Nursing Assessments, effective April 2024, directs staff members to verify patients’ prescriptions prior to the initiation of treatments. The prescription components to be verified include the correct dialysate composition such as the potassium and calcium. 2. The document titled, Patient Summary Report, showed Patient #8’s dialysis prescription with a start date of 4/18/25, showing dialysate bath of 2 K (potassium) and 2.5 Ca (Calcium), and a treatment time of 4 hours. 3. On 5/19/25 at 2:50 PM, Patient #8’s treatment was ongoing at Station #4. Observation showed that Patient #8’s dialysis treatment was connected to the dialysate port that delivered 3 K and 2.5 Ca. The dialysis machine indicated that Patient #8 had 1 hour and 24 minutes of remaining treatment time. Registered Nurse (RN) B, who was present during the observation, verified that Patient #8 was on the wrong dialysate bath. RN B stated Patient #8 should have been on a 2 K and 2.5 Ca dialysate as prescribed. RN B also verified that Patient #8 had been on treatment for 2.5 hours. 4. The document titled, Treatment Details Report, dated 5/19/25, noted Patient #8’s dialysate order as 2 K and 2.5 Ca, and that patient care technician (PCT) G verified Patient #8’s prescription at 11:59 AM. Patient #8’s treatment was initiated at 12:13 PM. The document also showed 2 staff members, PCT H and RN B, re-verified Patient #8’s prescription at 13:53 PM. The document did not reflect that Patient #8 received dialysis with a 3 K and 2.5 Ca dialysate as observed at 2:50 PM. 5. On 5/22/25 at 2:00 PM, the manager of clinical services (MCS) and the facility administrator (FA) acknowledged the importance of thorough verification and implementation of patients’ treatment orders.”
-
Effective Nutritional Status
The inspectors’ words, 412 words
“POC-EFFECTIVE NUTRITIONAL STATUS CFR(s): 494.90(a)(2) The interdisciplinary team must provide the necessary care and counseling services to achieve and sustain an effective nutritional status. A patient’s albumin level and body weight must be measured at least monthly. Additional evidence-based professionally-accepted clinical nutrition indicators may be monitored, as appropriate. This Standard is not met as evidenced by: 36083 Based on documents review, and staff interviews, the facility did not address the low trending albumin for 1 of 6 patients (Patient #4) reviewed for nutritional needs. The facility reported a census of 65 patients at the time of the survey. Findings include: 1. The policy #1-14-01, titled, Interdisciplinary Team (IDT) Patient Assessment and Plan of Care, dated October 2024, provides that the facility’s IDT will develop and implement a written, individualized comprehensive plan of care that specifies the services necessary to address the patient’s needs. The policy provides that the plan of care will address the “nutritional status which addresses the necessary care and counseling services provided by the IDT to achieve and sustain effective nutritional status. The policy also provides that a patient’s albumin level should be measured at least monthly. 2. The document titled, Patient Note, dated 1/31/25, indicated Patient #4 had a low albumin (nutritional indicator) of 3.4 g/dL (grams/deciliter) for the month of 1/25. The document also indicated Patient #4 was on protein supplement at home and disliked the ONS (oral nutritional supplement) in center. 3. The document titled, ICHD Comprehensive Note, dated 3/7/25, noted Patient #4’s low albumin of 3.1 g/dL on 2/24/25. The document did not show any action plan or intervention. 4. The document titled, Limited Note, dated 3/24/25, acknowledged Patient #4’s low albumin of 3.1 g/dL on 2/24/25, noted for pushing protein supplements at home. The document also indicated Patient #4 was on ONS in-center. 5. However, Patient #4’s Patient Summary Report, printed on 5/19/25, did not show any order for ONS among Patient #4’s in-center medications. The report also showed a low trending albumin, as follows: 3.2 g/dL on 3/24/25, 0 results for 4/25, and 3 g/dL on 5/9/25. 6. The document titled, ICHD Comprehensive Note, dated 5/16/24, also showed Patient #4’s latest albumin of 3 g/dL on 5/9/25. The document did not show any action plan or intervention to address the low albumin. 7. On 5/21/25 at 2:00 PM, the manager of clinical services (MCS) verified there was lack of evidence to show how Patient #4’s albumin was being addressed, despite the low trend.”
-
Md Resp - Ensure All Adhere To P&P
The inspectors’ words, 282 words
“MD RESP-ENSURE ALL ADHERE TO P&P CFR(s): 494.150(c)(2)(i) The medical director must- (2) Ensure that- (i) All policies and procedures relative to patient admissions, patient care, infection control, and safety are adhered to by all individuals who treat patients in the facility, including attending physicians and nonphysician providers; This Standard is not met as evidenced by: 36083 Based on documents review, and staff interviews, the facility did not ensure staff members completed the annual tuberculosis (TB) risk assessment for 8 of 13 staff members (Registered Nurse [RN] H, Administrative Assistant [AA] I, Patient Care Technician [PCT] J, Social Worker [SW] K, PCT M, Licensed Practical Nurse [LPN] N, PCT O, Facility Administrator [FA] P) who currently worked at the facility. The facility reported a total census of 65 patients at the time of the survey. Findings include: 1. The policy #4-06-05, titled, Tuberculosis Monitoring and Follow-Up, dated October 2024, outlines the policy purposes, including annual teammate requirements for completion of TB individual risk assessment and symptom evaluation. 2. A review of the personnel files for PCT M, showed the latest TB risk assessment and symptoms evaluation on file was dated 1/10/24. Further review of the personnel worksheet that the facility provided on 5/20/25, showed additional staff members with outdated TB risk assessment and symptoms evaluation, as follows: a. RN H dated 1/10/24 b. AA I dated 6/24/24 c. SW K dated 1/12/24 d. LPN N dated 1/10/24 e. PCT O dated 4/15/24 f. FA P dated 1/11/24 3. During an interview on 5/20/25 at 2:55 PM, FA P verified the lack of evidence to show completion of the required TB risk assessment and symptoms evaluation for the identified staff members listed above.”
All 2 inspections in the last three years
| Date | Visit | What the record says |
|---|---|---|
| May 21, 2025 | Standard inspection | 7 deficiencies cited |
| Dec 13, 2023 | Complaint inspection | No deficiencies cited |
Is it certified?
- Medicare-certified dialysis facility, certified or last recertified on Sep 7, 2018.
- Run for profit.
- No For hospices, home health agencies, hospitals and dialysis facilities, CMS writes deficiencies at two levels. Standard is the usual one; condition-level is the more serious, when a problem is serious enough that the provider doesn’t meet a whole condition of taking part in Medicare. Source: CMS, State Operations Manual. deficiency on record in the last three years.
- Chain: DaVita.
CMS, Dialysis Facility - Listing by Facility. Released Jul 15, 2026. Updated quarterly.
CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.
Has it been penalized?
- CMS doesn’t publish fines or other penalties for dialysis facilities.
- None of the deficiencies cited in the last three years came from an inspection that included a complaint investigation.
CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.
What does it offer?
- Offers in-center hemodialysis.
- Doesn’t offer peritoneal dialysis, home hemodialysis training and a shift starting at 5 p.m. or later.
- 12 dialysis stations.
- CMS doesn’t publish staffing levels for dialysis facilities.
CMS, Dialysis Facility - Listing by Facility and Patient survey (ICH CAHPS) - Facility. Released Jul 15, 2026. Updated quarterly.
Who owns it?
- Part of the DaVita chain, as CMS lists it.
- CMS publishes no owners file for dialysis facilities, so no other owner is named.
CMS, Dialysis Facility - Listing by Facility. Released Jul 15, 2026. Updated quarterly.
How do patients fare?
- CMS rates it 3 of 5 stars (Jan 1, 2021 to Dec 31, 2024).
- Compared by CMS with what it expects for the facility’s patients: patient survival, as expected; hospital admissions, as expected; readmissions to hospital, as expected; emergency department visits, as expected; emergency department visits within 30 days of a hospital stay, as expected; bloodstream infections, as expected; patients dialysing through a fistula, as expected; patients on a kidney transplant waitlist, as expected.
- CMS gives no CMS rates some kinds of place from 1 to 5 stars, more stars meaning better on CMS’s own measures for that kind: for a nursing home, its health inspections, staffing and quality measures. A rating is CMS’s summary of those measures; it doesn’t promise good care. Source: CMS, Care Compare and the Five-Star Quality Rating System.: “Too few completed survey responses to report.”
CMS, Dialysis Facility - Listing by Facility and Patient survey (ICH CAHPS) - Facility. Released Jul 15, 2026. Updated quarterly.
| Measure | Rating |
|---|---|
| Star ratingCMS’s star rating for dialysis facilities, 1 to 5 | 3 of 5 |
| Patient survey ratingCMS star rating from its survey of the facility’s in-center hemodialysis patients (ICH CAHPS), 1 to 5 | Not rated |
How does it compare nearby?
- Of the 9 dialysis facilities CMS lists in Polk County, 9 have a star rating from CMS: 3 rated 4 of 5, 4 rated 3 of 5, 2 rated 2 of 5.
- CMS rates this one 3 of 5.
CMS, Dialysis Facility - Listing by Facility. Released Jul 15, 2026. Updated quarterly.
What the record doesn’t say
- CMS doesn’t publish fines or other penalties for dialysis facilities, so none are shown.
- Only complaints that led to a citation appear; complaints that didn’t aren’t published.
- QCOR says it has no dialysis inspection reports after February 19, 2026, while it moves to a new system: a later inspection is not shown yet.
- CMS doesn’t publish staffing levels for dialysis facilities.
- CMS publishes no owners file for dialysis facilities: the chain it lists is the only owner named.
Sources
-
Centers for Medicare & Medicaid Services, Dialysis Facility - Listing by Facility (23ew-n7w9).
Released Jul 15, 2026 and checked Oct 30, 2026. Updated quarterly. Public domain (U.S. Government work).
-
Centers for Medicare & Medicaid Services, Patient survey (ICH CAHPS) - Facility (59mq-zhts).
Released Jul 15, 2026 and checked Oct 30, 2026. Updated quarterly. Public domain (U.S. Government work).
-
Centers for Medicare & Medicaid Services, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies (ESRD_2567s_2018_to_2026YTD.xlsx).
Released Oct 28, 2026 and checked Oct 30, 2026. Updated monthly. Public domain (U.S. Government work).
If you believe something here is wrong, a correction starts with the agency whose record this copies: CMS. CMS’s own record is on Care Compare. If Hearth Record copied something wrongly, it will fix it and log the correction publicly, with its date: how corrections work.
This copy of the record was made on Oct 30, 2026.
From the facility
The public record above comes first. Anything the facility adds will appear here, below it, and say who wrote it.
Replies
None. Replies aren’t open yet. When they open, the facility will be able to answer any finding for free, and the reply will show beside that finding, unedited and dated.
Paid listing
None. Paid listings aren’t open yet. When they open, anything paid for will say “Paid by the facility”, and paying will never change a finding, a rating or the order of results.