Hearth Record

Usrc Roswell

A dialysis facility in Roswell, Georgia 30076

11660 Alpharetta Hwy, Suite 650, Roswell, Georgia 30076. (678) 710-0970.

CMS’s own record, on Care Compare

Watch and the shortlist are kept with a free account, on every device. Your watch list. CMS’s own record is on Care Compare.

The short answer

Record last released by CMS on Oct 28, 2026.

The last 24 months 2 deficiencies in 1 month of the last 36. Last cited Jan 2024. Most serious: Standard-level. Every month

Each figure’s source sits beside it, in its section below.

What these words mean3
Star ratings
CMS rates some kinds of place from 1 to 5 stars, more stars meaning better on CMS’s own measures for that kind: for a nursing home, its health inspections, staffing and quality measures. A rating is CMS’s summary of those measures; it doesn’t promise good care. Source: CMS, Care Compare and the Five-Star Quality Rating System.
Inspection (survey)
A visit by state inspectors, often unannounced, who check a place against the rules it must meet. For nursing homes and other places Medicare pays, CMS calls these visits surveys: a standard survey of a nursing home comes at least every 15 months, and a complaint survey whenever a complaint calls for one. Source: CMS; 42 CFR 488.308.
Deficiency, citation, violation
What inspectors write up when a place didn’t meet a rule: the rule, what they saw, and when. CMS calls it a deficiency; states may say citation or violation. It is the inspectors’ finding, not a court’s, and the place is usually asked for a plan to correct it. Source: CMS, statement of deficiencies (Form CMS-2567); each state’s licensing agency.

What did inspectors find?

The last inspection on record was on Aug 23, 2024: a complaint inspection.

2 deficiencies cited in the last three years.

Source:

CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.

When those deficiencies happened

2 deficiencies in 1 month of the last 36. Last cited Jan 2024. Most serious: Standard-level. The last 3 years, to Oct 30, 2026.

2 deficiencies by month over the last 3 years. Each cell is one month.
JanFebMarAprMayJunJulAugSepOctNovDec
2023 NovDec
2024 JanFebMarAprMayJunJulAugSepOctNovDec
2025 JanFebMarAprMayJunJulAugSepOctNovDec
2026 JanFebMarAprMayJunJulAugSepOct

Hover or focus a month to read it.

No visit on record Visited, nothing cited A stronger orange is more serious, on its source’s own levels, read onto four bands: from the least serious it publishes to the most
Source:

Hearth Record drew this from the dates and levels in the source’s own records.

Each deficiency, as cited

Rule titles as CMS’s inspectors cite them, set in sentence case.

Source:

CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.

Jan 19, 2024: standard inspection2 deficiencies
  • Ic - Wear Gloves/Hand Hygiene

    The inspectors’ words, 315 words

    “IC-WEAR GLOVES/HAND HYGIENE CFR(s): 494.30(a)(1) Wear disposable gloves when caring for the patient or touching the patient’s equipment at the dialysis station. Staff must remove gloves and wash hands between each patient or station. This Standard is not met as evidenced by: 03383 Based on observation, a review of Centers for Disease Control and Prevention (CDC) recommendations, and staff interview, it was determined that the Infection Control Committee failed to ensure that one of one patient (P#5 ) observed who held pressure to her access sites for hemostasis (stopping of the flow of blood) after dialysis, and two of two Patient Care Technicians (PCT CC and PCT JJ) observed, performed hand hygiene (wash hands with soap and water or use an alcohol based hand sanitizer) after glove removal. This deficient practice had the potential for cross contamination and increased risk of infection and could affect 56 in-center hemodialysis patients who were dialyzing at this facility. Findings were: During observation in the patient treatment area on 1/17/24 between 1:00 p.m. and 2:45 p.m., the following was observed: - P#5, who was seated at Station (S) 1 held pressure to dialysis access needle sites and left the facility without performing hand hygiene. - P#5 was not reminded by the staff to wash hands nor offered to use hand sanitizer after glove removal. - PCT CC was observed performing tasks at S8 with gloved hands, removed gloves and without performing hand hygiene, donned a new pair of gloves and continued taking patient off dialysis at S8. - PCT LL was observed removing gloves and did not perform hand hygiene. According to CDC recommendations, even with glove use, hand hygiene is necessary after glove removal because hands can become contaminated through small defects in gloves and from the outer surface of gloves during glove removal. The Facility Administrator was informed about the above findings on 1/18/24 at 1:45 p.m.”

    Rule V0113. Standard-level.

  • Achieve Adequate Clearance

    The inspectors’ words, 661 words

    “POC-ACHIEVE ADEQUATE CLEARANCE CFR(s): 494.90(a)(1) Achieve and sustain the prescribed dose of dialysis to meet a hemodialysis Kt/V of at least 1.2 and a peritoneal dialysis weekly Kt/V of at least 1.7 or meet an alternative equivalent professionally-accepted clinical practice standard for adequacy of dialysis. This Standard is not met as evidenced by: 03383 Based on a review of patients’ treatment records, staff interview, and a review of facility policy, it was determined that the interdisciplinary team (IDT) failed to ensure that three of six in-center hemodialysis patients (P#3, P#6 and P#8) sampled, received their prescribed dialysis blood flow rate (BFR) to achieve and maintain adequate dialysis. Findings were: A review of treatment flowsheets showed the following: P#3: P#3’s Dialysis Prescription: Duration: 120 minutes (3 hours and 30 minutes), EDW (Estimated Dry Weight): 76 kg (kilogram), BFR: 400, DFR: 600. On 11/20/23: - P#3’s treatment started at 11:03 a.m. and was discontinued at 4:51 p.m. - Treatment record showed that BFR was decreased to 300 at 1:04 p.m. until 4:51 p.m. - The record did not show why the BFR was decreased to 300. On 1/02/24: - P#3’s treatment started at 12:28 p.m. and was discontinued at 2:56 p.m. -Treatment record showed that BFR was decreased from 400 to 300 at 12:59 p.m. until 2:56 p.m. - The record did not show why the BFR was decreased to 300. P#6: P#6’s Dialysis Prescription: Duration: 180 minutes (3 hours), EDW: 62.5 kg, BFR: 350, DFR: 600. On 1/15/24: - P#6’s treatment started at 12:09 p.m. and was discontinued at 3:13 p.m. - Treatment record showed that BFR was 200 at 12:09 p.m., was increased to 400 at 12:33 p.m., was decreased to 300 at 1:03 p.m., and remained at 300 until dialysis treatment was discontinued at 3:13 p.m. - The record did not show why the BFR was set to run at 300 instead of 350, as ordered. P#8: P#8’s Dialysis Prescription: Duration: 270 minutes (4 hours and 30 minutes), EDW: 105.5 kg, BFR: 400, DFR: 800. On 1/05/24: - P#8’s treatment started at 6:31 a.m. and was discontinued at 11:17 a.m. - Treatment record showed that the BFR was set at 250 at 6:31 a.m. and remained at this rate for the entire treatment that ended at 11:17 a.m. - There was a lack of documented reasons for not adhering to P#’s treatment plan as ordered. On 1/12/24: - P#8’s treatment started at 6:56 a.m. and was discontinued at 10:22 a.m. - Treatment record showed that the BFR was set at 350 and the DFR was set at 600 at 6:50 a.m. The BFR remained at 350 until 10:00 a.m. when it was increased to 400 until 10:06 a.m. and was decreased to 200 when dialysis was discontinued. - The DFR remained at 600 for the entire treatment. - The record did not show why the BFR was not set to run at 400 for the entire treatment, and why the DFR was set to run at 600 instead of 800 as ordered. On 1/17/24: - P#8’s treatment started at 6:50 a.m. and was discontinued at 11:18 a.m. - Treatment record showed that the BFR was 205 at 6:50 a.m., was increased to 400 at 7:03 a.m., was decreased to 350 at 9:33 a.m. and remained at 350 until 10:33 a.m. The BFR was decreased to 200 when dialysis treatment was discontinued at 11:18 a.m. - There was a lack of documented reasons for not adhering to P#’s treatment plan as ordered. - The Facility Administrator was informed on 1/19/24 at 4:23 p.m. and confirmed the above findings. The Policy titled, “Intradialytic Monitoring of Patient” dated September/2020 stated: Patient: Direct patient care staff will monitor the following parameters during each dialysis treatment: Delivery System: 3. Blood flow rate 4. Dialysate flow rate Intervention: - Modify the treatment plan based on the patient’s response, which must be documented by the charge nurse. - Notify patient’s physician of any significant change or problem.”

    Rule V0544. Standard-level.

All 2 inspections in the last three years
Inspections on record
DateVisitWhat the record says
Aug 23, 2024Complaint inspectionNo deficiencies cited
Jan 19, 2024Standard inspection2 deficiencies cited

Is it certified?

  • Medicare-certified dialysis facility, certified or last recertified on Dec 21, 2011.
  • Run for profit.
  • No deficiency on record in the last three years.
  • Chain: US Renal Care, Inc.
Source:

CMS, Dialysis Facility - Listing by Facility. Released Jul 15, 2026. Updated quarterly.

CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.

Has it been penalized?

  • CMS doesn’t publish fines or other penalties for dialysis facilities.
  • None of the deficiencies cited in the last three years came from an inspection that included a complaint investigation.
Source:

CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.

What does it offer?

  • Offers in-center hemodialysis, peritoneal dialysis and home hemodialysis training.
  • Doesn’t offer a shift starting at 5 p.m. or later.
  • 17 dialysis stations.
  • CMS doesn’t publish staffing levels for dialysis facilities.
Source:

CMS, Dialysis Facility - Listing by Facility and Patient survey (ICH CAHPS) - Facility. Released Jul 15, 2026. Updated quarterly.

Who owns it?

  • Part of the US Renal Care, Inc. chain, as CMS lists it.
  • CMS publishes no owners file for dialysis facilities, so no other owner is named.
Source:

CMS, Dialysis Facility - Listing by Facility. Released Jul 15, 2026. Updated quarterly.

How do patients fare?

  • CMS rates it 4 of 5 stars (Jan 1, 2021 to Dec 31, 2024).
  • Compared by CMS with what it expects for the facility’s patients: patient survival, as expected; hospital admissions, as expected; readmissions to hospital, as expected; blood transfusions, as expected; emergency department visits, as expected; emergency department visits within 30 days of a hospital stay, as expected; bloodstream infections, better than expected; patients dialysing through a fistula, as expected; patients put on a kidney transplant waitlist in their first year of dialysis, as expected; patients on a kidney transplant waitlist, as expected.
  • CMS gives no : “Too few completed survey responses to report.”
Source:

CMS, Dialysis Facility - Listing by Facility and Patient survey (ICH CAHPS) - Facility. Released Jul 15, 2026. Updated quarterly.

Ratings and measures, as published
MeasureRating
Star ratingCMS’s star rating for dialysis facilities, 1 to 54 of 5
Patient survey ratingCMS star rating from its survey of the facility’s in-center hemodialysis patients (ICH CAHPS), 1 to 5Not rated

How does it compare nearby?

  • Of the 35 dialysis facilities CMS lists in Fulton County, 32 have a star rating from CMS: 1 rated 5 of 5, 2 rated 4 of 5, 11 rated 3 of 5, 9 rated 2 of 5, 9 rated 1 of 5.
  • CMS rates this one 4 of 5.
Source:

CMS, Dialysis Facility - Listing by Facility. Released Jul 15, 2026. Updated quarterly.

What the record doesn’t say

  • CMS doesn’t publish fines or other penalties for dialysis facilities, so none are shown.
  • Only complaints that led to a citation appear; complaints that didn’t aren’t published.
  • QCOR says it has no dialysis inspection reports after February 19, 2026, while it moves to a new system: a later inspection is not shown yet.
  • CMS doesn’t publish staffing levels for dialysis facilities.
  • CMS publishes no owners file for dialysis facilities: the chain it lists is the only owner named.

Sources

If you believe something here is wrong, a correction starts with the agency whose record this copies: CMS. CMS’s own record is on Care Compare. If Hearth Record copied something wrongly, it will fix it and log the correction publicly, with its date: how corrections work.

Source:

This copy of the record was made on Oct 30, 2026.

From the facility

The public record above comes first. Anything the facility adds will appear here, below it, and say who wrote it.

Replies

None. Replies aren’t open yet. When they open, the facility will be able to answer any finding for free, and the reply will show beside that finding, unedited and dated.

Paid listing

None. Paid listings aren’t open yet. When they open, anything paid for will say “Paid by the facility”, and paying will never change a finding, a rating or the order of results.

How to read a record

Four things every record does, shown on an example record made up for this guide.

An example record, made up for this guide

An example nursing home

Made up for this guide: no real place is shown

Not fully inspected in over two years (CMS flag)

11 health citations at the latest inspection cycle

The state average is 14.3.

Source:

CMS, State and US Averages and Health Deficiencies. Released Oct 28, 2026. Updated monthly.

From the homeNone yet. Replies and paid listings aren’t open, and when they open they will sit here, below the record.

1 of 4

Every fact names its source.

Who published it, when, and how often it changes sit beside each fact, with a link to the agency’s own file.

Sign in

A free account keeps your watch list, shortlists, comparisons and saved searches on every device, and can email you when something you watch changes. Browsing never needs one.