Fresenius Medical Care Carroll County
A dialysis facility in Carrollton, Georgia 30116
305 Centennial Dr, Carrollton, Georgia 30116. (770) 832-2202.
Watch and the shortlist are kept with a free account, on every device. Your watch list. CMS’s own record is on Care Compare.
The short answer
Record last released by CMS on Oct 28, 2026.
- 3of 5 CMS’s star rating
- Not rated patient survey rating
- 4 deficiencies cited in the last three years
- 26 dialysis stations
Each figure’s source sits beside it, in its section below.
What these words mean3
- Star ratings
- CMS rates some kinds of place from 1 to 5 stars, more stars meaning better on CMS’s own measures for that kind: for a nursing home, its health inspections, staffing and quality measures. A rating is CMS’s summary of those measures; it doesn’t promise good care. Source: CMS, Care Compare and the Five-Star Quality Rating System.
- Inspection (survey)
- A visit by state inspectors, often unannounced, who check a place against the rules it must meet. For nursing homes and other places Medicare pays, CMS calls these visits surveys: a standard survey of a nursing home comes at least every 15 months, and a complaint survey whenever a complaint calls for one. Source: CMS; 42 CFR 488.308.
- Deficiency, citation, violation
- What inspectors write up when a place didn’t meet a rule: the rule, what they saw, and when. CMS calls it a deficiency; states may say citation or violation. It is the inspectors’ finding, not a court’s, and the place is usually asked for a plan to correct it. Source: CMS, statement of deficiencies (Form CMS-2567); each state’s licensing agency.
What did inspectors find?
The last inspection on record was on Sep 25, 2024: a standard inspection.
4 deficiencies cited in the last three years.
CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.
When those deficiencies happened
4 deficiencies in 1 month of the last 36. Last cited Sep 2024. Most serious: Standard-level. The last 3 years, to Oct 30, 2026.
| Jan | Feb | Mar | Apr | May | Jun | Jul | Aug | Sep | Oct | Nov | Dec | |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 2023 | Nov | Dec | ||||||||||
| 2024 | Jan | Feb | Mar | Apr | May | Jun | Jul | Aug | Sep | Oct | Nov | Dec |
| 2025 | Jan | Feb | Mar | Apr | May | Jun | Jul | Aug | Sep | Oct | Nov | Dec |
| 2026 | Jan | Feb | Mar | Apr | May | Jun | Jul | Aug | Sep | Oct |
Hover or focus a month to read it.
Hearth Record drew this from the dates and levels in the source’s own records.
Each deficiency, as cited
Rule titles as CMS’s inspectors cite them, set in sentence case.
CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.
Sep 25, 2024: standard inspection4 deficiencies
-
Pe - Comfortable Temperature
The inspectors’ words, 379 words
“PE-COMFORTABLE TEMPERATURE CFR(s): 494.60(c)(2) The dialysis facility must: (i) Maintain a comfortable temperature within the facility; and (ii) Make reasonable accommodations for the patients who are not comfortable at this temperature. This Standard is not met as evidenced by: 03383 Based on observation, a review of facility records and patient and staff interviews, it was determined that the facility failed to ensure that all patients and staff were provided with comfortable temperatures within the facility. The facility had 79 in-center hemodialysis patients and 11 staff (two registered Nurses, five Patient Care Technicians, two Licensed Practical Nurses, one part-time Social Worker, one part-time Dietitian, and one part-time Biomed Technician (BMT). Findings were: During survey on 9/24/24 and 9/25/24, six patients were observed completely covered with blanket from neck to feet and two patients were covered from head to toe. The patients indicated they were cold when staff approached them to keep access uncovered and covered access with blanket after blanket was removed. The thermostat on 9/25/24 at 8:45 a.m., showed the temperature in facility was 68 degrees Fahrenheit (F); the air was blowing down on the patients from vents located on ceiling. Staff complained about the temperatures in the facility and wore long sleeves and sweaters to stay warm. This surveyor also experienced frigid temperatures and wore long sleeves and jacket to stay warm. This surveyor noticed a significant difference between outdoor temperature and temperature upon entering the facility; felt like stepping into a freezer in the lobby and temperatures felt colder in the treatment area. Cold temperatures were discussed with the Facility Administrator (FA) and BMT on 9/25/24 at 8:45 a.m. BMT indicated temperatures were controlled by Fresenius and were kept between 68 and 70 and it was blowing down on the patients. The FA stated that she has received multiple complaints from both patients and staff, including herself about how cold it is in the facility; however, did not have any physical documentation of the complaints as the complaints were always verbal. Despite requesting a policy regarding temperature in the facility, the FA did not provide a policy for this. Cross-Reference V407 - Failure of the facility to ensure that patients’ dialysis access sites remained uncovered and visible to the staff throughout dialysis treatment, to ensure patient safety.”
-
Pe - Hemodialysis Patients In View During Treatments
The inspectors’ words, 374 words
“PE-HD PTS IN VIEW DURING TREATMENTS CFR(s): 494.60(c)(4) Patients must be in view of staff during hemodialysis treatment to ensure patient safety, (video surveillance will not meet this requirement). This Standard is not met as evidenced by: 03383 Based on observation and staff interviews, it was determined that the facility failed to ensure that eight of 39 patients (P) (P#11, P#12, P#13, P#14, P#17, P#18, P#19, and P#20) observed in the patient treatment area, had their vascular access (dialysis access) sites uncovered/visible to the staff throughout dialysis treatment, to ensure patient safety. This deficient practice could provide an opportunity for accidental needle dislodgement or a line disconnection to go undetected and could result in exsanguination (severe loss of blood). The facility in-center hemodialysis census was 79. Findings were: An observation in the patient treatment area on 9/24/24 between 8:42 a.m. and 10:50 a.m., revealed the following: - P#11 who was seated at Station (S) 3 had access completely covered by a blanket. - P#12 who was seated at S11 had access completely covered by a blanket. - P#13 who was seated at S7 had access completely covered by a blanket. - P#14 who was seated at S14 had access completely covered by a blanket. The patients’ dialysis access sites were not visible during their treatment. Registered Nurse (RN) CC was informed about patients with covered accesses on 9/24/24 at 11:15 a.m. RN CC stated that patients complained about the cold temperature in the treatment area and refused to keep access uncovered. An observation in the patient treatment area on 9/25/24 between 1:46 p.m. and 2:30 p.m. revealed the following: - P#17 who was seated at S20 had access completely covered by a blanket. - P#18 who was seated at S24 had access completely covered by a blanket. - P#19 who was seated at S2 had access completely covered by a blanket. - P#20 who was seated at S8 had access completely covered by a blanket. The Facility Administrator (FA) was informed and shown the above findings on 9/25/24 between 1:50 p.m. and 2:30 p.m. The FA stated patients were reminded not to cover their access; however, patients complained about the cold temperature in the treatment area and kept cover over access to stay warm.”
-
Monitor Water/Dialysate Inc On Site Evaluation
The inspectors’ words, 210 words
“H-MONITOR H20 /DIALYSATE INC ON SITE EVAL CFR(s): 494.100(c)(1)(v) Services include, but are not limited to, the following: (v) Monitoring of the quality of water and dialysate used by home hemodialysis patients including conducting an onsite evaluation This Standard is not met as evidenced by: 03383 Based on a review of facility policy and medical records and staff interviews, it was determined that the facility failed to ensure monitoring of the quality of water and dialysate used by one of one home hemodialysis patient was performed quarterly per facility policy. Findings were: A review of policy titled, NxStage PureFlow SL®: Testing For Microbiological Quality dated 5/2/22 revealed the following: Dialysate (SAK) Bacteriological Culture and Endotoxin analysis will be conducted: Initially: - Test within the first month of patient being at home, near the estimated end of a batch. Quarterly: - Near the estimated end of a batch. A review of cultures and endotoxin testing of NxStage PureFlow for P#10 revealed that NxStage PureFlow testing was performed on 1/8/24 and 9/4/24. Second quarter testing of NxStage PureFlow was not done. This was confirmed by the Home Hemodialysis Nurse (HHN) on 9/25/24 at 3:45 p.m. The HHN stated that the cultures are obtained by dialysis staff and that second quarter was missed.”
-
Continuously Monitor/Take Action/Track/Sustain Improve
The inspectors’ words, 409 words
“QAPI-MONITOR/ACT/TRACK/SUSTAIN IMPROVE CFR(s): 494.110(b) The dialysis facility must continuously monitor its performance, take actions that result in performance improvements, and track performance to ensure that improvements are sustained over time. This Standard is not met as evidenced by: 03383 Based on a review of the facility’s Fiscal Year 2024 Quarterly Dialysis Facility Report (FY2024 QDFR - A report prepared by the Centers for Medicare and Medicaid Services to provide a comparative summary of treatment patterns and patient outcomes for dialysis patients), a review of facility records, and staff interview, it was determined that the Quality Assessment and Performance Improvement (QAPI) Committee failed to make changes to plans of action to improve and sustain the facility’s Anemia Management, Bone/Mineral, and Nutrition for in-center hemodialysis (ICHD) patients. for three of three months (June 2024 - August 2024) of QAPI meeting minutes reviewed. This facility had 79 ICHD patients and 28 home patients. Findings were: A review of the facility’s FY2024 (third quarter 2024) QAPI meeting minutes, revealed that the facility was above the United States (US) threshold in: - Anemia - (Hemoglobin < (less than) 10.0 g/dl) - for ICHD patients at this facility was 30% in June 2024, 27% in July 2024, and 31.1% in August when compared to US at 23% nationally. - Mineral/Bone - (Phosphorus > (greater than) 7.0 mg/dL) - for ICHD patients at this facility was 20% in May 2024, and 20.1% in July and August 2024 when compared to US at 16% nationally. - Nutrition - (Albumin < 4.0 g/dl) - for ICHD patients at this facility was 72.1% in June 2024, 71.1% in July and 68.1% in August 2024 when compared to US at 51.3% nationally. - Mineral/Bone - (Phosphorus >7.0 mg/dL) - for Peritoneal Dialysis patients at this facility was 16.1% in June and 16.6% in August 2024 when compared to US at 12.6% nationally. Additionally, the facility’s QAPI meeting minutes from (May 2024 - August 2024) revealed documentary evidence that the interdisciplinary team (IDT) conducted a comprehensive review of anemia, but not nutrition or mineral/bone. No changes had been made to the action plans to ensure and sustain improvement in anemia. The Facility Administrator stated on 9/25/24 at approximately 2:36 p.m., that the IDT (interdisciplinary team) will work toward improvement of these outcomes. The FA confirmed no changes were made to the plan for anemia in June, July 2024, or August, and that mineral/bone (PO4) and nutrition (albumin) has not been addressed.”
All 2 inspections in the last three years
| Date | Visit | What the record says |
|---|---|---|
| Sep 25, 2024 | Standard inspection | 4 deficiencies cited |
| Sep 9, 2024 | Complaint inspection | No deficiencies cited |
Is it certified?
- Medicare-certified dialysis facility, certified or last recertified on Apr 21, 2005.
- Run for profit.
- No For hospices, home health agencies, hospitals and dialysis facilities, CMS writes deficiencies at two levels. Standard is the usual one; condition-level is the more serious, when a problem is serious enough that the provider doesn’t meet a whole condition of taking part in Medicare. Source: CMS, State Operations Manual. deficiency on record in the last three years.
- Chain: Fresenius Medical Care.
CMS, Dialysis Facility - Listing by Facility. Released Jul 15, 2026. Updated quarterly.
CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.
Has it been penalized?
- CMS doesn’t publish fines or other penalties for dialysis facilities.
- None of the deficiencies cited in the last three years came from an inspection that included a complaint investigation.
CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.
What does it offer?
- Offers in-center hemodialysis and peritoneal dialysis.
- Doesn’t offer home hemodialysis training and a shift starting at 5 p.m. or later.
- 26 dialysis stations.
- CMS doesn’t publish staffing levels for dialysis facilities.
CMS, Dialysis Facility - Listing by Facility and Patient survey (ICH CAHPS) - Facility. Released Jul 15, 2026. Updated quarterly.
Who owns it?
- Part of the Fresenius Medical Care chain, as CMS lists it.
- CMS publishes no owners file for dialysis facilities, so no other owner is named.
CMS, Dialysis Facility - Listing by Facility. Released Jul 15, 2026. Updated quarterly.
How do patients fare?
- CMS rates it 3 of 5 stars (Jan 1, 2021 to Dec 31, 2024).
- Compared by CMS with what it expects for the facility’s patients: patient survival, as expected; hospital admissions, as expected; readmissions to hospital, as expected; blood transfusions, as expected; emergency department visits, as expected; emergency department visits within 30 days of a hospital stay, as expected; bloodstream infections, better than expected; patients dialysing through a fistula, as expected; patients put on a kidney transplant waitlist in their first year of dialysis, as expected; patients on a kidney transplant waitlist, as expected.
- CMS gives no CMS rates some kinds of place from 1 to 5 stars, more stars meaning better on CMS’s own measures for that kind: for a nursing home, its health inspections, staffing and quality measures. A rating is CMS’s summary of those measures; it doesn’t promise good care. Source: CMS, Care Compare and the Five-Star Quality Rating System.: “Too few completed survey responses to report.”
CMS, Dialysis Facility - Listing by Facility and Patient survey (ICH CAHPS) - Facility. Released Jul 15, 2026. Updated quarterly.
| Measure | Rating |
|---|---|
| Star ratingCMS’s star rating for dialysis facilities, 1 to 5 | 3 of 5 |
| Patient survey ratingCMS star rating from its survey of the facility’s in-center hemodialysis patients (ICH CAHPS), 1 to 5 | Not rated |
How does it compare nearby?
- Of the 4 dialysis facilities CMS lists in Carroll County, 4 have a star rating from CMS: 2 rated 4 of 5, 1 rated 3 of 5, 1 rated 2 of 5.
- CMS rates this one 3 of 5.
CMS, Dialysis Facility - Listing by Facility. Released Jul 15, 2026. Updated quarterly.
| Place | Star rating |
|---|---|
| Fmcna Villa Rica | 4 |
| Davita North Carrollton Dialysis | 2 |
| Fresenius Kidney Care West Georgia | 4 |
What the record doesn’t say
- CMS doesn’t publish fines or other penalties for dialysis facilities, so none are shown.
- Only complaints that led to a citation appear; complaints that didn’t aren’t published.
- QCOR says it has no dialysis inspection reports after February 19, 2026, while it moves to a new system: a later inspection is not shown yet.
- CMS doesn’t publish staffing levels for dialysis facilities.
- CMS publishes no owners file for dialysis facilities: the chain it lists is the only owner named.
Sources
-
Centers for Medicare & Medicaid Services, Dialysis Facility - Listing by Facility (23ew-n7w9).
Released Jul 15, 2026 and checked Oct 30, 2026. Updated quarterly. Public domain (U.S. Government work).
-
Centers for Medicare & Medicaid Services, Patient survey (ICH CAHPS) - Facility (59mq-zhts).
Released Jul 15, 2026 and checked Oct 30, 2026. Updated quarterly. Public domain (U.S. Government work).
-
Centers for Medicare & Medicaid Services, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies (ESRD_2567s_2018_to_2026YTD.xlsx).
Released Oct 28, 2026 and checked Oct 30, 2026. Updated monthly. Public domain (U.S. Government work).
If you believe something here is wrong, a correction starts with the agency whose record this copies: CMS. CMS’s own record is on Care Compare. If Hearth Record copied something wrongly, it will fix it and log the correction publicly, with its date: how corrections work.
This copy of the record was made on Oct 30, 2026.
From the facility
The public record above comes first. Anything the facility adds will appear here, below it, and say who wrote it.
Replies
None. Replies aren’t open yet. When they open, the facility will be able to answer any finding for free, and the reply will show beside that finding, unedited and dated.
Paid listing
None. Paid listings aren’t open yet. When they open, anything paid for will say “Paid by the facility”, and paying will never change a finding, a rating or the order of results.