Davita Kissimmee Home Training Pd
A dialysis facility in Kissimmee, Florida 34741
1203 N Central Ave #a, Kissimmee, Florida 34741. (407) 518-9232.
Watch and the shortlist are kept with a free account, on every device. Your watch list. CMS’s own record is on Care Compare.
The short answer
Record last released by CMS on Oct 28, 2026.
- 3of 5 CMS’s star rating
- Not rated patient survey rating
- 4 deficiencies cited in the last three years
- 4 dialysis stations
Each figure’s source sits beside it, in its section below.
What these words mean3
- Star ratings
- CMS rates some kinds of place from 1 to 5 stars, more stars meaning better on CMS’s own measures for that kind: for a nursing home, its health inspections, staffing and quality measures. A rating is CMS’s summary of those measures; it doesn’t promise good care. Source: CMS, Care Compare and the Five-Star Quality Rating System.
- Inspection (survey)
- A visit by state inspectors, often unannounced, who check a place against the rules it must meet. For nursing homes and other places Medicare pays, CMS calls these visits surveys: a standard survey of a nursing home comes at least every 15 months, and a complaint survey whenever a complaint calls for one. Source: CMS; 42 CFR 488.308.
- Deficiency, citation, violation
- What inspectors write up when a place didn’t meet a rule: the rule, what they saw, and when. CMS calls it a deficiency; states may say citation or violation. It is the inspectors’ finding, not a court’s, and the place is usually asked for a plan to correct it. Source: CMS, statement of deficiencies (Form CMS-2567); each state’s licensing agency.
What did inspectors find?
The last inspection on record was on Aug 30, 2024: a standard inspection.
4 deficiencies cited in the last three years.
CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.
When those deficiencies happened
4 deficiencies in 1 month of the last 36. Last cited Aug 2024. Most serious: Standard-level. The last 3 years, to Oct 30, 2026.
| Jan | Feb | Mar | Apr | May | Jun | Jul | Aug | Sep | Oct | Nov | Dec | |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 2023 | Nov | Dec | ||||||||||
| 2024 | Jan | Feb | Mar | Apr | May | Jun | Jul | Aug | Sep | Oct | Nov | Dec |
| 2025 | Jan | Feb | Mar | Apr | May | Jun | Jul | Aug | Sep | Oct | Nov | Dec |
| 2026 | Jan | Feb | Mar | Apr | May | Jun | Jul | Aug | Sep | Oct |
Hover or focus a month to read it.
Hearth Record drew this from the dates and levels in the source’s own records.
Each deficiency, as cited
Rule titles as CMS’s inspectors cite them, set in sentence case.
CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.
Aug 30, 2024: standard inspection4 deficiencies
-
Ic - Clean/Dirty Areas, Med Prep Area, No Common Med Carts
The inspectors’ words, 357 words
“IC-CLEAN/DIRTY;MED PREP AREA;NO COMMON CARTS CFR(s): 494.30(a)(1)(i) Clean areas should be clearly designated for the preparation, handling and storage of medications and unused supplies and equipment. Clean areas should be clearly separated from contaminated areas where used supplies and equipment are handled. Do not handle and store medications or clean supplies in the same or an adjacent area to that where used equipment or blood samples are handled. When multiple dose medication vials are used (including vials containing diluents), prepare individual patient doses in a clean (centralized) area away from dialysis stations and deliver separately to each patient. Do not carry multiple dose medication vials from station to station. Do not use common medication carts to deliver medications to patients. If trays are used to deliver medications to individual patients, they must be cleaned between patients. This Standard is not met as evidenced by: 13640 Based on observation, interview and a review of facility documentation, the facility failed to ensure that equipment used in preparing patient lab work in the form of a centrifuge was stored in a clean area. Findings: During an observation of the lab area of the facility on 8/29/24 at approximately 11:30 AM, the area beneath a sink was observed. A centrifuge was found stored beneath the sink. During an interview with the Regional Home Manager at this time she stated the centrifuge was designated for the isolation part of the lab and was reserved for use in processing any lab work for hepatitis B patients (of which there were none on the census). The placement of items associated with patient care are at an increased risk of exposure to microbes beneath a sink as there is a possibility of moisture leaking from above. A review of facility policy Infection Control for Dialysis Facilities revealed the following: “Clean areas should be clearly separated from contaminated areas where used supplies and equipment are handled. . . . Clean supplies or equipment will not be placed adjacent to a sink unless a splash guard is in place.” During an interview with the Administrator on 8/30/24 at 12:20 PM, she confirmed the policy was not followed.”
-
Pe - Safe, Functional, Comfortable Environment
The inspectors’ words, 182 words
“PE-SAFE/FUNCTIONAL/COMFORTABLE ENVIRONMENT CFR(s): 494.60 The dialysis facility must be designed, constructed, equipped, and maintained to provide dialysis patients, staff, and the public a safe, functional, and comfortable treatment environment. This Standard is not met as evidenced by: 13640 Based on observation and interview, the facility failed to provide a safe treatment environment free of expired medications. Findings: During an observation in the medication storage area in training room #9 on 8/29/24 at approximately 12:02 PM, one previously opened multi-dose vial of Heparin Sodium Injection USP, 30,000 units / 30 ML (milliliters) was discovered. The vial did not have a date on its label of when the vial had first been used and was without a date of when it had been opened. It was not possible to determine whether or not the expiration date had passed. A review of facility’s Medication Policy noted it required: “Each vial is labeled with the initials of the person opening the vial and the expiration date.” During an interview of the Administrator on 8/30/24 at approximately 2:31 PM, she confirmed the policy had not been followed.”
-
Fac Receive/Review Self Monitoring Data Every 2 Months
The inspectors’ words, 328 words
“H-FAC RECEIVE/REVIEW PT RECORDS Q 2 MONTHS CFR(s): 494.100(b)(2),(3) The dialysis facility must - (2) Retrieve and review complete self-monitoring data and other information from self-care patients or their designated caregiver(s) at least every 2 months; and (3) Maintain this information in the patient ’ s medical record. This Standard is not met as evidenced by: 13252 Based on record review and interview the facility failed to identify inconsistencies on the patient treatment flow sheets, address these concerns with the patient, and ensure patient adherence to treatment plan for 1 of 2 home hemodialysis patients of a total sample of 10 patients (#4). Findings: Patient #4 admitted to the facility on 7/26/24 and elected a modality of home hemodialysis, where he treats himself. The physician orders noted the patient to treat himself four times a week with a treatment time each day of 3 hours and 30 minutes. Ten of patient #4’s treatment flow sheets, from 7/18/24 to 8/14/24, were reviewed. Patient’s dialysis access is an arteriovenous fistula that has to be monitored for bruit & thrill, pre and post treatment. In 10 of 10 treatment flow sheets reviewed, the patient noted an absence of bruit and thrill. This could be an indication the patient’s fistula is not functioning efficiently or is clotted. Further review revealed the patient was shortening his treatments and not following the physician’s prescribed treatment time of 3 hours and 30 minutes. The patient also noted that his treatment solution had chlorine levels of greater than 0.1 ppm (parts per million). On 8/30/24 at 2:24 PM, Patient #4’s treatment flow sheets were discussed with the facility administrator (FA). She provided the Registered Nurse’s (RN) treatment review for treatments from 7/26/24 to 8/15/24. The RN failed to identify the treatment irregularities and noted, “...treatments and medications have been completed as expected...” The FA stated the nurse would review the treatment flow sheets again and that patient may need re-education on the home hemodialysis process. 13640”
-
Mr - Maintain Home Patient Records
The inspectors’ words, 171 words
“MR-MAINTAIN HOME PT RECORDS CFR(s): 494.170(b)(3) (3) The dialysis facility must complete, maintain, and monitor home care patients’ records, including the records of patients who receive supplies and equipment from a durable medical equipment supplier. This Standard is not met as evidenced by: 13640 Based on interview and record review, the facility failed to ensure that home care records for peritoneal dialysis patients were monitored with respect to blood pressure discrepancies in one of ten sampled patients. (#1) Findings: A review of patient #1’s “Clara Treatment Summary Reports”, which are submitted electronically from patients at their home after a peritoneal dialysis session, revealed there was no patient input for pre-treatment blood pressure on the following dates: 8/5/24; 8/7/24; 8/8/24; and 8/11/24. A review of nursing documentation for patient #1’s monthly visit to the facility did not reveal any evidence of inquiries or education concerning the recording of pre-treatment blood pressures in the “Clara Treatment Summary Reports”. During an interview with the Administrator on 8/30/24 at 3:00 PM, she confirmed the findings.”
The one inspection in the last three years
| Date | Visit | What the record says |
|---|---|---|
| Aug 30, 2024 | Standard inspection | 4 deficiencies cited |
Is it certified?
- Medicare-certified dialysis facility, certified or last recertified on Jun 6, 2013.
- Run for profit.
- No For hospices, home health agencies, hospitals and dialysis facilities, CMS writes deficiencies at two levels. Standard is the usual one; condition-level is the more serious, when a problem is serious enough that the provider doesn’t meet a whole condition of taking part in Medicare. Source: CMS, State Operations Manual. deficiency on record in the last three years.
- Chain: DaVita.
CMS, Dialysis Facility - Listing by Facility. Released Jul 15, 2026. Updated quarterly.
CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.
Has it been penalized?
- CMS doesn’t publish fines or other penalties for dialysis facilities.
- None of the deficiencies cited in the last three years came from an inspection that included a complaint investigation.
CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.
What does it offer?
- Offers peritoneal dialysis and home hemodialysis training.
- Doesn’t offer in-center hemodialysis and a shift starting at 5 p.m. or later.
- 4 dialysis stations.
- CMS doesn’t publish staffing levels for dialysis facilities.
CMS, Dialysis Facility - Listing by Facility and Patient survey (ICH CAHPS) - Facility. Released Jul 15, 2026. Updated quarterly.
Who owns it?
- Part of the DaVita chain, as CMS lists it.
- CMS publishes no owners file for dialysis facilities, so no other owner is named.
CMS, Dialysis Facility - Listing by Facility. Released Jul 15, 2026. Updated quarterly.
How do patients fare?
- CMS rates it 3 of 5 stars (Jan 1, 2021 to Dec 31, 2024).
- Compared by CMS with what it expects for the facility’s patients: patient survival, as expected; hospital admissions, worse than expected; readmissions to hospital, worse than expected; blood transfusions, as expected; emergency department visits, as expected; emergency department visits within 30 days of a hospital stay, as expected; patients dialysing through a fistula, as expected; patients put on a kidney transplant waitlist in their first year of dialysis, as expected; patients on a kidney transplant waitlist, as expected.
- CMS gives no CMS rates some kinds of place from 1 to 5 stars, more stars meaning better on CMS’s own measures for that kind: for a nursing home, its health inspections, staffing and quality measures. A rating is CMS’s summary of those measures; it doesn’t promise good care. Source: CMS, Care Compare and the Five-Star Quality Rating System.: “Survey data not available for this reporting period.”
CMS, Dialysis Facility - Listing by Facility and Patient survey (ICH CAHPS) - Facility. Released Jul 15, 2026. Updated quarterly.
| Measure | Rating |
|---|---|
| Star ratingCMS’s star rating for dialysis facilities, 1 to 5 | 3 of 5 |
| Patient survey ratingCMS star rating from its survey of the facility’s in-center hemodialysis patients (ICH CAHPS), 1 to 5 | Not rated |
How does it compare nearby?
- Of the 8 dialysis facilities CMS lists in Osceola County, 8 have a star rating from CMS: 1 rated 3 of 5, 5 rated 2 of 5, 2 rated 1 of 5.
- CMS rates this one 3 of 5.
CMS, Dialysis Facility - Listing by Facility. Released Jul 15, 2026. Updated quarterly.
What the record doesn’t say
- CMS doesn’t publish fines or other penalties for dialysis facilities, so none are shown.
- Only complaints that led to a citation appear; complaints that didn’t aren’t published.
- QCOR says it has no dialysis inspection reports after February 19, 2026, while it moves to a new system: a later inspection is not shown yet.
- CMS doesn’t publish staffing levels for dialysis facilities.
- CMS publishes no owners file for dialysis facilities: the chain it lists is the only owner named.
Sources
-
Centers for Medicare & Medicaid Services, Dialysis Facility - Listing by Facility (23ew-n7w9).
Released Jul 15, 2026 and checked Oct 30, 2026. Updated quarterly. Public domain (U.S. Government work).
-
Centers for Medicare & Medicaid Services, Patient survey (ICH CAHPS) - Facility (59mq-zhts).
Released Jul 15, 2026 and checked Oct 30, 2026. Updated quarterly. Public domain (U.S. Government work).
-
Centers for Medicare & Medicaid Services, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies (ESRD_2567s_2018_to_2026YTD.xlsx).
Released Oct 28, 2026 and checked Oct 30, 2026. Updated monthly. Public domain (U.S. Government work).
If you believe something here is wrong, a correction starts with the agency whose record this copies: CMS. CMS’s own record is on Care Compare. If Hearth Record copied something wrongly, it will fix it and log the correction publicly, with its date: how corrections work.
This copy of the record was made on Oct 30, 2026.
From the facility
The public record above comes first. Anything the facility adds will appear here, below it, and say who wrote it.
Replies
None. Replies aren’t open yet. When they open, the facility will be able to answer any finding for free, and the reply will show beside that finding, unedited and dated.
Paid listing