CARESCAPE Patient Data Module (PDM) used with the following monitors: CARESCAPE B450/B650/B850, SOLAR 8000M/I…
Medical device recall Z-2424-2020. Published in FDA’s Enforcement Report on Jul 1, 2020.
No Watch here, and no alerts: openFDA asks that its enforcement data “should not be used as a method to collect data to issue alerts to the public, nor should it be used to track the lifecycle of a recall” (openFDA). For FDA’s own recall emails, subscribe at FDA. FDA’s own record is on accessdata.fda.gov.
The short answer
Published in FDA’s Enforcement Report on Jul 1, 2020. Copied from openFDA on Oct 20, 2026.
- Class II FDA’s class
- Ongoing its status, in FDA’s file
- Not named no state, in where it went
- 89,109 units how much, in FDA’s words
Every line below is in FDA’s own words, with its source beside it. FDA’s terms are explained in FDA’s own words.
How serious is it, by FDA’s class?
Class II, the middle of FDA’s three classes.
“Products that might cause a temporary health problem, or pose only a slight threat of a serious nature. Example: a drug that is under-strength but that is not used to treat life-threatening situations.”
openFDA, in plain words, its enforcement report fields.
“Class II is a situation in which use of, or exposure to, a violative product may cause temporary or medically reversible adverse health consequences or where the probability of serious adverse health consequences is remote.”
FDA’s rule, 21 CFR 7.3(m)(2), eCFR.
What these words mean is quoted from openFDA’s field reference and 21 CFR 7.3.
What’s wrong with it?
The CARESCAPE Patient Data Module (PDM) is used with the following monitors: CARESCAPE B450/B650/B850, SOLAR 8000M/I and Transport Pro. If Pace detection is turned ON, on the monitor, and if an Automated External Defibrillator (AED) is used to perform defibrillation, the low frequency signals deployed by the AED, cause the PDM to issue a false flat line ECG waveform and alarm Asystole to be displayed on the monitor.
FDA, Device recall enforcement reports. Released Oct 14, 2026. Updated weekly.
Which ones are recalled?
CARESCAPE Patient Data Module (PDM) used with the following monitors: CARESCAPE B450/B650/B850, SOLAR 8000M/I and Transport Pro, Model Numbers: 2042084-001 2094504-001 2042084-001-046050 2042084-001-208621 2042084-001-045915 2042084-001-215164 2042084-001-078474 2042084-001-053034 2042084-001-215165 2042084-001-079462 2042084-001-047389 2042084-001-112198 2042084-001-041673 2042084-001-227238 2042084-001-071564 2042084-001-503824 2042084-001-119839 2042084-001-569269 2042084-001-041674 2042084-001-047549 2042084-001-514651 2042084-001-163572 2042084-001-583721 2042084-001-427592 2042084-001-527358 2042084-001-583723 2042084-001-317166 2042084-001-583724 2042084-001-583715 2042084-001-583718 2042084-001-055156 2042084-001-583722 2042084-001-041835 2042084-001-074124 2042084-001-583706 2042084-001-583707 2042084-001-519926 2042084-001-583717 2042084-001-583713 2042084-001-207863 2042084-001-460604 2042084-001-079192 2042084-001-197663 2042084-001-045872 2042084-001-053195 2042084-001-092010 2042084-001-560824 2042084-001-052372 2042084-001-071088 2042084-001-046667 2042084-001-213006 2042084-001-086202 2042084-001-301821 2042084-001-045720 2042084-001-060454 2042084-001-418294 2042084-001-088907 2042084-001-065769 2042084-001-589530 2042084-001-623792 2042084-001-187563 2042084-001-320333 2042084-001-357143 2042084-001-148302 To be provided 2042084-001-082825 2042084-001-057016 2042084-001-153601 2042084-001-161552 2042084-001-140229 2042084-001-611704 2042084-001-626688 2042084-001-389208 2042084-001-657836 2042084-001-225214 2042084-001-503162 2042084-001-477881 2042084-001-316025 2042084-001-046826 2042084-001-245255 2042084-001-196543 2042084-001-557725 2042084-001-505890 2042084-001-218596 2042084-001-336980 2042084-001-524525 2042084-001-600032 2042084-001-529732 2042084-001-195742 2042084-001-195782 2042084-001-573889 2042084-001-573890 2042084-001-573886 2042084-001-573887 2042084-001-195822 2042084-001-195862 2042084-001-048420 2042084-001-065538 2042084-001-055814 2042084-001-341260 2042084-001-149220 2042084-001-079193 2042084-001-229282 2042084-001-629486 2042084-001-058695 2042084-001-061170 2042084-001-629548 2042084-001-080803 2042084-001-596662 2042084-001-250146 2042084-001-202515 2042084-001-515709 2042084-001-579491 2042084-001-505608 2042084-001-065010 2042084-001-619171
89,109 units, in FDA’s words.
FDA, Device recall enforcement reports. Released Oct 14, 2026. Updated weekly.
Codes to check against yours
All Model Numbers that contain software versions 2.6 or 2.7
Copied exactly as FDA lists them: lot and serial numbers, dates and other codes on the product or its label.
Where did it go?
FDA’s words for the “general area of initial distribution”: where the firm first shipped it.
Worldwide Distribution
These words name no state.
The words say it went outside the United States too.
FDA, Device recall enforcement reports. Released Oct 14, 2026. Updated weekly.
Is it still going on?
Ongoing, in FDA’s file.
“A recall which is currently in progress.”
openFDA, on “On-Going”, its enforcement report fields.
What these words mean is quoted from openFDA’s field reference and 21 CFR 7.3.
- The firm began the recall on May 18, 2020.
- FDA classified it on Jun 23, 2020.
- FDA’s Enforcement Report published it on Jul 1, 2020.
FDA, Device recall enforcement reports. Released Oct 14, 2026. Updated weekly.
Who is recalling it?
- GE Healthcare, LLC, of Waukesha, WI.
- Who began it, in FDA’s words: Voluntary: Firm initiated.
- How the firm first told its customers: Letter.
FDA, Device recall enforcement reports. Released Oct 14, 2026. Updated weekly.
What this record can’t tell you
- Whether your own one is affected: compare the codes, dates and numbers above with yours. When unsure, ask the firm or the store.
- Where it went after the firm’s first shipments. FDA’s words cover the firm’s initial distribution, and, in FDA’s words, “subsequent distribution by the consignees to other parties may not be included.”
- How many have been returned, corrected or destroyed: FDA’s report doesn’t say.
- Whether anyone was hurt or fell ill: the report doesn’t say.
- How current it is: openFDA publishes FDA’s Enforcement Report weekly, after FDA does, and a firm can announce a recall weeks before it appears there. openFDA’s own caution: “This data should not be used as a method to collect data to issue alerts to the public, nor should it be used to track the lifecycle of a recall.”
- A product with no recall here isn’t safe by that: FDA’s report lists the recalls FDA classified, and when.
Hearth Record wrote these lines; the quotations are FDA’s.