Cordis PRECISE (R) PRO RX Nitinol Stent System (Carotid)
Medical device recall Z-1946-2016. Published in FDA’s Enforcement Report on Jun 22, 2016.
No Watch here, and no alerts: openFDA asks that its enforcement data “should not be used as a method to collect data to issue alerts to the public, nor should it be used to track the lifecycle of a recall” (openFDA). For FDA’s own recall emails, subscribe at FDA. FDA’s own record is on accessdata.fda.gov.
The short answer
Published in FDA’s Enforcement Report on Jun 22, 2016. Copied from openFDA on Oct 20, 2026.
- Class II FDA’s class
- Terminated its status, in FDA’s file
- Nationwide FDA’s word for where it went
- 4,400 units in US and 3,100 units in Foreign Countries how much, in FDA’s words
Every line below is in FDA’s own words, with its source beside it. FDA’s terms are explained in FDA’s own words.
How serious is it, by FDA’s class?
Class II, the middle of FDA’s three classes.
“Products that might cause a temporary health problem, or pose only a slight threat of a serious nature. Example: a drug that is under-strength but that is not used to treat life-threatening situations.”
openFDA, in plain words, its enforcement report fields.
“Class II is a situation in which use of, or exposure to, a violative product may cause temporary or medically reversible adverse health consequences or where the probability of serious adverse health consequences is remote.”
FDA’s rule, 21 CFR 7.3(m)(2), eCFR.
What these words mean is quoted from openFDA’s field reference and 21 CFR 7.3.
What’s wrong with it?
Inability to deploy the stent or partial stent deployment.
FDA, Device recall enforcement reports. Released Oct 14, 2026. Updated weekly.
Which ones are recalled?
Cordis PRECISE (R) PRO RX Nitinol Stent System (Carotid)
4,400 units in US and 3,100 units in Foreign Countries, in FDA’s words.
FDA, Device recall enforcement reports. Released Oct 14, 2026. Updated weekly.
Codes to check against yours
Catalog Number: PC0520RXC, Lot Numbers: 17298513, 17340803; Catalog Number: PC0530RXC, Lot Numbers: 17283329, 17286330, 17333401 and 17376719; Catalog Number: PC0540RXC, Lot Numbers: 17295225 , 17312647, 17337070 and 17366679; Catalog…
Every code shown here, 1,998 characters
Catalog Number: PC0520RXC, Lot Numbers: 17298513, 17340803; Catalog Number: PC0530RXC, Lot Numbers: 17283329, 17286330, 17333401 and 17376719; Catalog Number: PC0540RXC, Lot Numbers: 17295225 , 17312647, 17337070 and 17366679; Catalog Number: PC0620RXC, Lot Numbers: 17256203, 17264566, 17282136 and 17382573; Catalog Number: PC0630RXC, Lot Numbers: 17255095, 17264568, 17287132, 17294353, 17306044, 17308314, 17328366, 17337071, 17364507, 17388949 and 17392573; Catalog Number: PC0640RXC, Lot Numbers: 17249849, 17264995, 17283330, 17296211, 17331381, 17356085, 17364567, 17370803 and 17392574; Catalog Number: PC0720RXC, Lot Numbers: 17249850 and 17260987; Catalog Number: PC0730RXC, Lot Numbers: 17256214, 17264569, 17276754, 17290641, 17322268,17332269, 17341779, 17347010, 17357107, 17361603, 17381650 and 17386230; Catalog Number: PC0740RXC, Lot Numbers: 17250948, 17253599, 17264571, 17282140, 17287345, 17295226, 17308316, 17322270, 17325372, 17331383, 17335082, 17344455, 17351475, 17361605, 17371407 and 17378613; Catalog Number: PC0820RXC, Lot Numbers: 17260988 and 17347026; Catalog Number: PC0830RXC, Lot Numbers: 17250952, 17256217, 17259977, 17265886, 17270630, 17280875, 17291876, 17294239, 17323767, 17328144, 17335802, 17340809,17349810, 17357109, 17360669, 17364569, 17369477,17376721, 17379881, 17381652 and 17388950; Catalog Number: PC0840RXC, Lot Numbers: 17247325, 17251834, 17259051, 17264572, 17276782, 17287346, 17296212, 17306048,17321489, 17325375, 17328145,17335084, 17335085, 17346758, 17346759, 17349811, 17356086, 17360672, 17364570, 17370806 and 17379882; Catalog Number: PC0920RXC, Lot Numbers: 17269319 and 17388951; Catalog Number: PC0930RXC, Lot Numbers: 17251837, 17274483, 17290643, 17298514, 17312648, 17313248, 17349018 , 17357110, 17361606, 17366682 and 17393271; Catalog Number: PC0940RXC, Lot Number: 17260989, 17264998, 17270632, 17272818, 17280877, 17307877, 17312649, 17319031, 17319032, 17329303, 17339531, 17349019, 17354593, 17386232, 17387886 and…
FDA’s list runs to 2,492 characters. The first part is shown; the rest is on FDA’s record.
Copied exactly as FDA lists them: lot and serial numbers, dates and other codes on the product or its label.
Where did it go?
FDA’s words for the “general area of initial distribution”: where the firm first shipped it.
NATIONWIDE and FOREIGN CONSIGNEES: Japan, Taiwan, Thailand and South Korea.
These words name no state.
What FDA means by nationwide
“The term “nationwide” is defined to mean the fifty states or a significant portion. Note that subsequent distribution by the consignees to other parties may not be included.”
openFDA, its enforcement report fields.
The words say it went outside the United States too.
What these words mean is quoted from openFDA’s field reference and 21 CFR 7.3.
Is it still going on?
Terminated, in FDA’s file.
“FDA has determined that all reasonable efforts have been made to remove or correct the violative product in accordance with the recall strategy, and proper disposition has been made according to the degree of hazard.”
openFDA, on “Terminated”, its enforcement report fields.
What these words mean is quoted from openFDA’s field reference and 21 CFR 7.3.
- The firm began the recall on May 4, 2016.
- FDA classified it on Jun 10, 2016.
- FDA’s Enforcement Report published it on Jun 22, 2016.
- FDA terminated it on Jul 26, 2019.
FDA, Device recall enforcement reports. Released Oct 14, 2026. Updated weekly.
Who is recalling it?
- Cordis Corporation, of Miami Lakes, FL.
- Who began it, in FDA’s words: Voluntary: Firm initiated.
- How the firm first told its customers: Two or more of the following: Email, Fax, Letter, Press Release, Telephone, Visit.
FDA, Device recall enforcement reports. Released Oct 14, 2026. Updated weekly.
What this record can’t tell you
- Whether your own one is affected: compare the codes, dates and numbers above with yours. When unsure, ask the firm or the store.
- Where it went after the firm’s first shipments. FDA’s words cover the firm’s initial distribution, and, in FDA’s words, “subsequent distribution by the consignees to other parties may not be included.”
- How many have been returned, corrected or destroyed: FDA’s report doesn’t say.
- Whether anyone was hurt or fell ill: the report doesn’t say.
- How current it is: openFDA publishes FDA’s Enforcement Report weekly, after FDA does, and a firm can announce a recall weeks before it appears there. openFDA’s own caution: “This data should not be used as a method to collect data to issue alerts to the public, nor should it be used to track the lifecycle of a recall.”
- FDA’s list of codes runs to 2,492 characters; the first part is shown here, and the rest is on FDA’s record.
- A product with no recall here isn’t safe by that: FDA’s report lists the recalls FDA classified, and when.
Hearth Record wrote these lines; the quotations are FDA’s.
Sources
-
U.S. Food and Drug Administration, Device recall enforcement reports.
Released Oct 14, 2026 and checked Oct 20, 2026. Updated weekly. Public domain (CC0 1.0, openFDA). FDA asks that nothing suggest it endorses this site.
Recalls of food, medicines, medical devices, pet food and animal drugs are from the U.S. Food and Drug Administration (FDA). FDA does not endorse Hearth Record. openFDA: “Do not rely on openFDA to make decisions regarding medical care.” Copied on Oct 20, 2026.