Hearth Record

Invacare Homecare Series Bed and Invacare G-Series Beds Containing Component

Medical device recall Z-1251-2024. Published in FDA’s Enforcement Report on Mar 13, 2024.

FDA’s own record, on accessdata.fda.gov

No Watch here, and no alerts: openFDA asks that its enforcement data “should not be used as a method to collect data to issue alerts to the public, nor should it be used to track the lifecycle of a recall” (openFDA). For FDA’s own recall emails, subscribe at FDA. FDA’s own record is on accessdata.fda.gov.

The short answer

Published in FDA’s Enforcement Report on Mar 13, 2024. Copied from openFDA on Oct 20, 2026.

Every line below is in FDA’s own words, with its source beside it. FDA’s terms are explained in FDA’s own words.

How serious is it, by FDA’s class?

Class II, the middle of FDA’s three classes.

“Products that might cause a temporary health problem, or pose only a slight threat of a serious nature. Example: a drug that is under-strength but that is not used to treat life-threatening situations.”

openFDA, in plain words, its enforcement report fields.

“Class II is a situation in which use of, or exposure to, a violative product may cause temporary or medically reversible adverse health consequences or where the probability of serious adverse health consequences is remote.”

FDA’s rule, 21 CFR 7.3(m)(2), eCFR.

Source:

What these words mean is quoted from openFDA’s field reference and 21 CFR 7.3.

What’s wrong with it?

Invacare Homecare & G-Series Bed Components identified with a potential weld defect leads to premature weld failures to occur on these components

Source:

FDA, Device recall enforcement reports. Released Oct 14, 2026. Updated weekly.

Which ones are recalled?

Invacare Homecare Series Bed and Invacare G-Series Beds Containing Component Model Numbers: (1) G50 (2) G53 (3) G54 (4) BAR5490IVC (5) BAR5000IVC (6) 5000IVC (7) 5490IVC (8) 5490LOW

8,117 units, in FDA’s words.

Source:

FDA, Device recall enforcement reports. Released Oct 14, 2026. Updated weekly.

Codes to check against yours

(1) G50 HEAD SECTION FULL ELECTRIC G-SERIES BED Serial Number 23HX000383 23HX000384 23HX000385 23HX000386 23HX000387 23HX000388 23HX000389 23HX000390 23HX000391 23HX000392 23HX000396 23HX000406 23HX000407 23HX000408 23HX000409 23HX000410…

Every code shown here, 1,998 characters

(1) G50 HEAD SECTION FULL ELECTRIC G-SERIES BED Serial Number 23HX000383 23HX000384 23HX000385 23HX000386 23HX000387 23HX000388 23HX000389 23HX000390 23HX000391 23HX000392 23HX000396 23HX000406 23HX000407 23HX000408 23HX000409 23HX000410 23HX000411 23HX000412 23HX000413 23HX000414 23HX000421 23HX000437 23HX000438 23HX000453 23HX000454 23HX000456 23HX000457 23HX000458 23HX000459 23HX000460 23HX000461 23HX000462 23HX000463 23HX000464 23HX000470 23HX000471 23HX000474 23HX000475 23HX000476 23HX000477 23HX000478 23HX000479 23HX000480 23HX000481 23HX000482 23HX000483 23HX000484 23HX000485 23HX000486 23HX000487 23HX000488 23HX000489 23HX000490 23HX000491 23HX000492 23HX000493 23HX000494 23HX000495 23HX000496 23HX000497 23HX000498 23HX000499 23HX000500 23HX000501 23HX000502 23HX000503 23HX000504 23HX000505 23HX000506 23HX000507 23HX000513 23HX000514 23HX000515 23HX000521 23HX000522 23HX000524 23HX000530 23HX000531 23HX000534 23HX000535 23HX000536 23HX000537 23HX000538 23HX000539 23HX000540 23HX000541 23HX000542 23HX000543 23HX000544 23HX000545 23HX000546 23HX000561 23HX000562 23HX000563 23HX000564 23HX000566 23HX000568 23HX000569 23HX000570 23HX000572 23HX000573 23HX000574 23HX000579 23HX000581 23HX000582 23HX000598 23HX000599 23HX000600 23HX000601 23HX000602 23HX000608 23HX000609 23HX000610 23HX000611 23HX000612 23HX000613 23HX000614 23HX000615 23HX000616 23HX000617 23HX000618 23HX000619 23HX000620 23HX000621 23HX000622 23HX000638 23HX000639 23HX000640 23HX000641 23HX000642 23HX000643 23HX000644 23HX000645 23HX000646 23HX000647 23HX000658 23HX000659 23HX000660 23HX000661 23HX000662 23HX000663 23HX000664 23HX000665 23HX000666 23HX000667 23HX000668 23HX000669 23HX000670 23HX000671 23HX000672 23HX000675 23HX000676 23HX000677 23HX000679 23HX000680 23HX000688 23HX000689 23HX000690 23HX000691 23HX000692 23HX000693 23HX000694 23HX000695 23HX000696 23HX000697 23HX000698 23HX000699 23HX000700 23HX000701 23HX000702 23HX000703 23HX000704 23HX000705 23HX000706 23HX000707 23HX000708…

FDA’s list runs to 73,796 characters. The first part is shown; the rest is on FDA’s record.

Source:

Copied exactly as FDA lists them: lot and serial numbers, dates and other codes on the product or its label.

Where did it go?

FDA’s words for the “general area of initial distribution”: where the firm first shipped it.

US Nationwide distribution.

These words name no state.

What FDA means by nationwide

“The term “nationwide” is defined to mean the fifty states or a significant portion. Note that subsequent distribution by the consignees to other parties may not be included.”

openFDA, its enforcement report fields.

Source:

What these words mean is quoted from openFDA’s field reference and 21 CFR 7.3.

Is it still going on?

Ongoing, in FDA’s file.

“A recall which is currently in progress.”

openFDA, on “On-Going”, its enforcement report fields.

Source:

What these words mean is quoted from openFDA’s field reference and 21 CFR 7.3.

  • The firm began the recall on Jan 22, 2024.
  • FDA classified it on Mar 4, 2024.
  • FDA’s Enforcement Report published it on Mar 13, 2024.
Source:

FDA, Device recall enforcement reports. Released Oct 14, 2026. Updated weekly.

Who is recalling it?

  • Invacare Corporation, of Elyria, OH.
  • Who began it, in FDA’s words: Voluntary: Firm initiated.
  • How the firm first told its customers: Letter.
Source:

FDA, Device recall enforcement reports. Released Oct 14, 2026. Updated weekly.

What this record can’t tell you

  • Whether your own one is affected: compare the codes, dates and numbers above with yours. When unsure, ask the firm or the store.
  • Where it went after the firm’s first shipments. FDA’s words cover the firm’s initial distribution, and, in FDA’s words, “subsequent distribution by the consignees to other parties may not be included.”
  • How many have been returned, corrected or destroyed: FDA’s report doesn’t say.
  • Whether anyone was hurt or fell ill: the report doesn’t say.
  • How current it is: openFDA publishes FDA’s Enforcement Report weekly, after FDA does, and a firm can announce a recall weeks before it appears there. openFDA’s own caution: “This data should not be used as a method to collect data to issue alerts to the public, nor should it be used to track the lifecycle of a recall.”
  • FDA’s list of codes runs to 73,796 characters; the first part is shown here, and the rest is on FDA’s record.
  • A product with no recall here isn’t safe by that: FDA’s report lists the recalls FDA classified, and when.
Source:

Hearth Record wrote these lines; the quotations are FDA’s.

Sources

  • U.S. Food and Drug Administration, Device recall enforcement reports.

    Released Oct 14, 2026 and checked Oct 20, 2026. Updated weekly. Public domain (CC0 1.0, openFDA). FDA asks that nothing suggest it endorses this site.

Source:

Recalls of food, medicines, medical devices, pet food and animal drugs are from the U.S. Food and Drug Administration (FDA). FDA does not endorse Hearth Record. openFDA: “Do not rely on openFDA to make decisions regarding medical care.” Copied on Oct 20, 2026.

How to read a record

Four things every record does, shown on an example record made up for this guide.

An example record, made up for this guide

An example nursing home

Made up for this guide: no real place is shown

Not fully inspected in over two years (CMS flag)

11 health citations at the latest inspection cycle

The state average is 14.3.

Source:

CMS, State and US Averages and Health Deficiencies. Released Oct 28, 2026. Updated monthly.

From the homeNone yet. Replies and paid listings aren’t open, and when they open they will sit here, below the record.

1 of 4

Every fact names its source.

Who published it, when, and how often it changes sit beside each fact, with a link to the agency’s own file.

Sign in

A free account keeps your watch list, shortlists, comparisons and saved searches on every device, and can email you when something you watch changes. Browsing never needs one.