No Watch here, and no alerts: openFDA asks that its enforcement data “should not be used as a method to collect data to issue alerts to the public, nor should it be used to track the lifecycle of a recall” (openFDA). For FDA’s own recall emails, subscribe at FDA. FDA’s own record is on accessdata.fda.gov.
The short answer
Published in FDA’s Enforcement Report on Nov 19, 2025. Copied from openFDA on Oct 20, 2026.
- Class II FDA’s class
- Ongoing its status, in FDA’s file
- Nationwide FDA’s word for where it went
- 2857 how much, in FDA’s words
Every line below is in FDA’s own words, with its source beside it. FDA’s terms are explained in FDA’s own words.
How serious is it, by FDA’s class?
Class II, the middle of FDA’s three classes.
“Products that might cause a temporary health problem, or pose only a slight threat of a serious nature. Example: a drug that is under-strength but that is not used to treat life-threatening situations.”
openFDA, in plain words, its enforcement report fields.
“Class II is a situation in which use of, or exposure to, a violative product may cause temporary or medically reversible adverse health consequences or where the probability of serious adverse health consequences is remote.”
FDA’s rule, 21 CFR 7.3(m)(2), eCFR.
What these words mean is quoted from openFDA’s field reference and 21 CFR 7.3.
What’s wrong with it?
Potential loss of monitoring on affected monitors when powered by certain batteries. Affected batteries can lose capability to hold charge and provide back up power. If this situation occurs, it will cause loss of patient monitoring and potentially delay recognizing patient status changes requiring treatment.
FDA, Device recall enforcement reports. Released Oct 14, 2026. Updated weekly.
Which ones are recalled?
BATTERY FLEX-3S2P 10.8V 18650 LI-ION SMBUS used with affected patient monitors Model No 2062895-001 Manufacturer Part Number U80296-1R01, revision S
2857, in FDA’s words.
FDA, Device recall enforcement reports. Released Oct 14, 2026. Updated weekly.
Codes to check against yours
No UDI Manufacturing date range (YYYY-MM-DD date format, located underneath date of manufacture symbol): 2024-11-25 - 2025-05-31; 2025-07-07 Serial Nos. 021725-20339 021725-22682 120924-06125 120924-05011 120924-05830 120924-03583…
Every code shown here, 1,988 characters
No UDI Manufacturing date range (YYYY-MM-DD date format, located underneath date of manufacture symbol): 2024-11-25 - 2025-05-31; 2025-07-07 Serial Nos. 021725-20339 021725-22682 120924-06125 120924-05011 120924-05830 120924-03583 120924-04467 120924-04447 031425-28687 120924-04436 120924-04240 021725-21549 021725-20604 5567418-SO-1-1 031425-30157 031425-28597 031425-29489 031425-28901 031425-28978 031425-28590 031425-29484 031425-29177 021725-21521 021725-20357 021725-20412 021725-22331 120924-04465 120924-07616 120924-07484 120924-07792 120924-07909 120924-07359 120924-07524 120924-06997 120924-07861 120924-08477 120924-07878 120924-07726 120924-07799 120924-08618 120924-07791 120924-08527 120924-07862 120924-08616 120924-08622 031425-29009 031425-28366 031425-30139 031425-28758 031425-29924 031425-29879 031425-28136 031425-29340 031425-29934 031425-28144 031425-28970 031425-29883 031425-28120 031425-27976 031425-29349 031425-28713 031425-28188 021725-22330 021725-21579 021725-21271 021725-20338 021725-20573 021725-21576 021725-22607 021725-20579 021725-22599 021725-21251 010625-13475 021725-22701 120924-05740 031425-28162 031425-29868 031425-28705 031425-29295 031425-29944 031425-29899 022625-25420 022625-26187 022625-25158 022625-26232 022625-26208 022625-26814 022625-26256 022625-26220 022625-26867 022625-26890 031425-28985 031425-30149 120924-04966 120924-04244 120924-06139 120924-08030 120924-05493 120924-07728 120924-05393 120924-04387 120924-05428 120924-06013 120924-04841 120924-08550 120924-06003 120924-06135 120924-04210 021725-22415 031425-30066 031425-28908 031425-28289 031425-28010 031425-29583 031425-28980 031425-30088 031425-28467 031425-28402 031425-28164 031425-28699 031425-28036 031425-29029 031425-29593 031425-29205 031425-28994 031425-29211 031425-28425 031425-28051 031425-28130 031425-29646 031425-28424 031425-28446 031425-29630 031425-27842 031425-29012 031425-27815 031425-28055 031425-29897 031425-28768 031425-28749 031425-29054…
FDA’s list runs to 37,505 characters. The first part is shown; the rest is on FDA’s record.
Copied exactly as FDA lists them: lot and serial numbers, dates and other codes on the product or its label.
Where did it go?
FDA’s words for the “general area of initial distribution”: where the firm first shipped it.
Worldwide - US Nationwide distribution.
These words name no state.
What FDA means by nationwide
“The term “nationwide” is defined to mean the fifty states or a significant portion. Note that subsequent distribution by the consignees to other parties may not be included.”
openFDA, its enforcement report fields.
The words say it went outside the United States too.
What these words mean is quoted from openFDA’s field reference and 21 CFR 7.3.
Is it still going on?
Ongoing, in FDA’s file.
“A recall which is currently in progress.”
openFDA, on “On-Going”, its enforcement report fields.
What these words mean is quoted from openFDA’s field reference and 21 CFR 7.3.
- The firm began the recall on Sep 26, 2025.
- FDA classified it on Nov 7, 2025.
- FDA’s Enforcement Report published it on Nov 19, 2025.
FDA, Device recall enforcement reports. Released Oct 14, 2026. Updated weekly.
Who is recalling it?
- GE Healthcare Finland Oy, of Helsinki, Finland.
- Who began it, in FDA’s words: Voluntary: Firm initiated.
- How the firm first told its customers: Letter.
FDA, Device recall enforcement reports. Released Oct 14, 2026. Updated weekly.
What this record can’t tell you
- Whether your own one is affected: compare the codes, dates and numbers above with yours. When unsure, ask the firm or the store.
- Where it went after the firm’s first shipments. FDA’s words cover the firm’s initial distribution, and, in FDA’s words, “subsequent distribution by the consignees to other parties may not be included.”
- How many have been returned, corrected or destroyed: FDA’s report doesn’t say.
- Whether anyone was hurt or fell ill: the report doesn’t say.
- How current it is: openFDA publishes FDA’s Enforcement Report weekly, after FDA does, and a firm can announce a recall weeks before it appears there. openFDA’s own caution: “This data should not be used as a method to collect data to issue alerts to the public, nor should it be used to track the lifecycle of a recall.”
- FDA’s list of codes runs to 37,505 characters; the first part is shown here, and the rest is on FDA’s record.
- A product with no recall here isn’t safe by that: FDA’s report lists the recalls FDA classified, and when.