I-T-E Circuit Breaker Box Inspection Program Announced By Siemens
Home product recall 88-091. Announced by CPSC on Nov 1, 1998.
Watch and the shortlist are kept with a free account, on every device. Your watch list. CPSC’s own notice is on cpsc.gov.
The short answer
Announced by CPSC on Nov 1, 1998. Copied from CPSC on Oct 19, 2026.
Every line below is in CPSC’s own words, with its source beside it.
What’s wrong with it?
The notice gives no hazard in a field of its own.
CPSC, Recalls API. Checked Oct 19, 2026. Updated daily.
What should you do?
The notice gives no remedy in a field of its own.
CPSC, Recalls API. Checked Oct 19, 2026. Updated daily.
Which ones are recalled?
I-T-E Circuit Breaker Box Inspection Program Announced By Siemens NEWS from CPSC U.S. Consumer Product Safety Commission Office of Information and Public Affairs Washington, DC 20207 Note: Telephone number change. FOR IMMEDIATE RELEASE Originally issued November 1, 1988, Revised June 21, 2004 Release # 88-9l Siemens Announces Free I-T-E Circuit Breaker Box Inspection Program WASHINGTON, DC - In cooperation with the U.S. Consumer Product Safety Commission, the Circuit Protection Division of Siemens Energy & Automation, Inc. of Alpharetta, Georgia is voluntarily offering free inspection and correction of certain of its I-T-E brand circuit-breaker boxes (load centers) installed between September 1986 and May 1987. Siemens is extending a program begun in November 1986 when it discovered that some of the circuit-breaker boxes were manufactured using components of an incorrect material, which could cause overheating and malfunction. The involved ITE circuit-breaker boxes, or “load centers” can be identified by a five digit code marked on the top of the wiring diagram label inside the door which is opened to reset the circuit breakers. The specific date codes involved are as follows: H2586-H3186 (H = August, days 25 through 31, 86 = year) J0186-J3086 (J = September, days I through 30, 86 = year) K0186-K2486 (K = October, days I through 24, 86 = year) Example: A product manufactured on September 24, 1986 bears the code J2486. Anyone locating such a load center which does not have an “inspected lugs” sticker should call Siemens at 1-800-241-3138 to arrange for free professional inspection of the unit. If the wiring diagram label has an “inspected lugs” stamp, the load center has already been inspected and corrected if necessary.
I-T-E circuit-breaker boxes.
CPSC, Recalls API. Checked Oct 19, 2026. Updated daily.
Who made and sold it?
- Made by Siemens Energy & Automation.
CPSC, Recalls API. Checked Oct 19, 2026. Updated daily.
Was anyone hurt?
The notice doesn’t say whether anyone was hurt.
CPSC, Recalls API. Checked Oct 19, 2026. Updated daily.
What the record doesn’t say
- The notice lists no UPCs, so check the model, the description and the photos.
- The notice lists no model numbers in a field of their own; its description may give them.
- How many have been returned or fixed isn’t in the notice.
Hearth Record wrote these lines.
Sources
-
U.S. Consumer Product Safety Commission, Recalls API.
Checked Oct 19, 2026. Updated daily. Public domain (U.S. Government work). CPSC asks to be credited, and that no endorsement be implied.
Recalls of kids’ and home products are from the U.S. Consumer Product Safety Commission (CPSC). CPSC does not endorse Hearth Record. Copied on Oct 19, 2026.