Hearth Record

Global Industrial Recalls Workbench Components Due To Electrical Shock Hazard

Home product recall 11-724. Announced by CPSC on Mar 9, 2011.

  • CPSC: stop using it
CPSC’s own notice, on cpsc.gov

Watch and the shortlist are kept with a free account, on every device. Your watch list. CPSC’s own notice is on cpsc.gov.

The short answer

Announced by CPSC on Mar 9, 2011. Copied from CPSC on Oct 19, 2026.

Every line below is in CPSC’s own words, with its source beside it.

What’s wrong with it?

Misrouted wiring in the electrical outlets on the workbench risers, aprons and shelves, and reverse polarity in some workbench power cords pose an electric shock hazard.

Source:

CPSC, Recalls API. Checked Oct 19, 2026. Updated daily.

What should you do?

Consumers should immediately unplug their workbench power cords and stop using the electrical outlets on the workbenches. Additionally, they should remove the power cord from the workbench. Global is contacting its customers directly and either sending replacement risers, aprons and shelves with properly wired outlets and replacement power cords or sending technicians on-site to repair faulty wiring and replace faulty power cords.

Source:

CPSC, Recalls API. Checked Oct 19, 2026. Updated daily.

  • : repair.
  • How to reach the firm: For additional information, contact Global’s Customer Service Manager at the following toll free number (855) 657-0424 from 9:00 am to 5:00 pm ET or email the customer service manager at MMarshall@globalindustrial.com

Which ones are recalled?

This recall affects all workbenches with the following components: - The Power Riser is made of steel, has an 18-inch shelf with four duplex receptacles and an on/off switch mounted along the front. It comes in gray only and in lengths of 60, 72 and 96 inches. The riser attaches to the top of the bench. - The Power Apron is made of steel, has three duplex receptacles and an on/off switch mounted in one of the long cross beams. It comes in blue or tan and in lengths of 48, 60, 72 and 96 inches. - The Power Shelf is made of steel, has three duplex receptacles and an on/off switch mounted on the front. It comes in blue or tan and in lengths of 48, 60, 72 and 96 inches. It attaches to a pair of 48-inch uprights.

About 5,000 units, as CPSC gives them.

Global Workbench Power Risers, Power Aprons and Power Shelves.

Source:

CPSC, Recalls API. Checked Oct 19, 2026. Updated daily.

CPSC’s photos

CPSC shows 3 photos on its notice. Hearth Record doesn’t copy them; each opens on cpsc.gov.

Who made and sold it?

  • Made by Global Equipment Company, Port Washington, N.Y., dba Global Industrial.
  • Global Industrial sold the workbench components through its catalogs and on the Internet, from January 9, 2009 to December 24, 2010 for approximately $85 to $516.
  • Made in China, as the notice gives it.
Source:

CPSC, Recalls API. Checked Oct 19, 2026. Updated daily.

Was anyone hurt?

Global has received eight reports of misrouted wires.

Source:

CPSC, Recalls API. Checked Oct 19, 2026. Updated daily.

What the record doesn’t say

  • The notice lists no UPCs, so check the model, the description and the photos.
  • The notice lists no model numbers in a field of their own; its description may give them.
  • How many have been returned or fixed isn’t in the notice.
Source:

Hearth Record wrote these lines.

Sources

  • U.S. Consumer Product Safety Commission, Recalls API.

    Checked Oct 19, 2026. Updated daily. Public domain (U.S. Government work). CPSC asks to be credited, and that no endorsement be implied.

Source:

Recalls of kids’ and home products are from the U.S. Consumer Product Safety Commission (CPSC). CPSC does not endorse Hearth Record. Copied on Oct 19, 2026.

How to read a record

Four things every record does, shown on an example record made up for this guide.

An example record, made up for this guide

An example nursing home

Made up for this guide: no real place is shown

Not fully inspected in over two years (CMS flag)

11 health citations at the latest inspection cycle

The state average is 14.3.

Source:

CMS, State and US Averages and Health Deficiencies. Released Oct 8, 2026. Updated monthly.

From the homeNone yet. Replies and paid listings aren’t open, and when they open they will sit here, below the record.

1 of 4

Every fact names its source.

Who published it, when, and how often it changes sit beside each fact, with a link to the agency’s own file.

Sign in

A free account keeps your watch list, shortlists, comparisons and saved searches on every device, and can email you when something you watch changes. Browsing never needs one.