CPSC, SCG Miyairi Announce Recall of Liquid Propane Overfill Protection Devices
Home product recall 04-070. Announced by CPSC on Jan 27, 2004.
- CPSC: stop using it
Watch and the shortlist are kept with a free account, on every device. Your watch list. CPSC’s own notice is on cpsc.gov.
The short answer
Announced by CPSC on Jan 27, 2004. Copied from CPSC on Oct 19, 2026.
- Stop using it what CPSC tells owners to do now (needs attention)
- 21,000 units, as CPSC gives them
- None injuries, CPSC’s notice says
Every line below is in CPSC’s own words, with its source beside it.
What’s wrong with it?
When the cylinder on the gas grill is filled to capacity and exposed to increased temperatures, liquid propane, instead of gas vapor, can leak out and cause the gas regulator valve to freeze. When the regulator valve thaws, if it has not been turned off, gas will flow to the grill. The resulting build-up of gas in the grill can pose a serious fire hazard to consumers.
CPSC, Recalls API. Checked Oct 19, 2026. Updated daily.
What should you do?
Consumers should stop using the gas cylinders immediately and contact the company. SCG will identify, for callers who have one of the recalled units, a local LP gas exchange center, which will replace the cylinder with one that has a new OPD valve. Do not take the LP gas cylinder to an LP gas refiller. Consumers should not attempt to remove the OPD or gas valve themselves.
CPSC, Recalls API. Checked Oct 19, 2026. Updated daily.
- How to reach the firm: Call SCG Miyairi at (800) 636-9346 between 8 a.m. and 8 p.m. ET Monday through Friday or visit their website at www.scgmiyairi.com
Which ones are recalled?
The recalled SCG Overfill Prevention Devices (OPD) have “V5QA OPD” engraved on the body and handle and either “DT 3.8” or “DT 3.8A” printed on one side of the wrench pad and “07-02,” “08-02,” or “10-98” printed on the other side. The valves are installed on 20-pound liquid propane gas cylinders manufactured by the Sahamitr Pressure Container Public Co. Ltd. in Thailand. The cylinders are marked “SMPC DOT-4BA240” and have a serial number in the range of 375201 to 396800. There is no hazard with the cylinders.
21,000 units, as CPSC gives them.
SCG Liquid Propane Overfill Protection Devices (OPD valves).
CPSC, Recalls API. Checked Oct 19, 2026. Updated daily.
CPSC’s photos
CPSC shows 3 photos on its notice. Hearth Record doesn’t copy them; each opens on cpsc.gov.
Who made and sold it?
- Made by SCG Miyairi (Thailand) Company, LTD, Thailand.
- Department and hardware stores nationwide sold the gas cylinders with the recalled OPD valves, from August 2002 through August 2003, for about $30. Some cylinders also were sold with certain Sunbeam gas grills.
- Made in Thailand, as the notice gives it.
CPSC, Recalls API. Checked Oct 19, 2026. Updated daily.
Was anyone hurt?
SCG has received five reports involving leaks from the OPD valve, though no injuries have been reported.
CPSC, Recalls API. Checked Oct 19, 2026. Updated daily.
What the record doesn’t say
- The notice lists no UPCs, so check the model, the description and the photos.
- The notice lists no model numbers in a field of their own; its description may give them.
- How many have been returned or fixed isn’t in the notice.
Hearth Record wrote these lines.
Sources
-
U.S. Consumer Product Safety Commission, Recalls API.
Checked Oct 19, 2026. Updated daily. Public domain (U.S. Government work). CPSC asks to be credited, and that no endorsement be implied.
Recalls of kids’ and home products are from the U.S. Consumer Product Safety Commission (CPSC). CPSC does not endorse Hearth Record. Copied on Oct 19, 2026.