Bennett County Hospital and Nursing Home - Cah
A critical access hospital in Martin, South Dakota 57551
102 Major Allen Post Office Box 70d, Martin, South Dakota 57551. (605) 685-6622.
Watch and the shortlist are kept with a free account, on every device. Your watch list. CMS’s own record is on Care Compare.
The short answer
Record last released by CMS on Oct 20, 2026.
- Not rated CMS’s overall rating
- Not rated patient survey rating
- 13 deficiencies cited in the last three years
- 14 beds
Each figure’s source sits beside it, in its section below.
What these words mean2
- Inspection (survey)
- A visit by state inspectors, often unannounced, who check a place against the rules it must meet. For nursing homes and other places Medicare pays, CMS calls these visits surveys: a standard survey of a nursing home comes at least every 15 months, and a complaint survey whenever a complaint calls for one. Source: CMS; 42 CFR 488.308.
- Deficiency, citation, violation
- What inspectors write up when a place didn’t meet a rule: the rule, what they saw, and when. CMS calls it a deficiency; states may say citation or violation. It is the inspectors’ finding, not a court’s, and the place is usually asked for a plan to correct it. Source: CMS, statement of deficiencies (Form CMS-2567); each state’s licensing agency.
What did inspectors find?
The last inspection on record was on Apr 25, 2024: a standard inspection.
13 deficiencies cited in the last three years.
CMS, QCOR Hospital 2567 statements of deficiencies. Released Oct 20, 2026. Updated monthly.
When those deficiencies happened
13 deficiencies in 1 month of the last 36. Last cited Apr 2024. Most serious: Standard-level. The last 3 years, to Nov 5, 2026.
| Jan | Feb | Mar | Apr | May | Jun | Jul | Aug | Sep | Oct | Nov | Dec | |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 2023 | Dec | |||||||||||
| 2024 | Jan | Feb | Mar | Apr | May | Jun | Jul | Aug | Sep | Oct | Nov | Dec |
| 2025 | Jan | Feb | Mar | Apr | May | Jun | Jul | Aug | Sep | Oct | Nov | Dec |
| 2026 | Jan | Feb | Mar | Apr | May | Jun | Jul | Aug | Sep | Oct | Nov |
Hover or focus a month to read it.
Hearth Record drew this from the dates and levels in the source’s own records.
Each deficiency, as cited
Rule titles as CMS’s inspectors cite them, set in sentence case.
CMS, QCOR Hospital 2567 statements of deficiencies. Released Oct 20, 2026. Updated monthly.
Apr 25, 2024: standard inspection6 deficiencies
-
Compliance Fed, St, And Local Laws And Regs
The inspectors’ words, 126 words
“COMPLIANCE FED, ST, AND LOCAL LAWS AND REGS CFR(s): The CAH is in compliance with applicable Federal laws and regulations related to the health and safety of patients. This Standard is not met as evidenced by: 45383 Based on record review and interview the provider failed to ensure thirty of thirty sampled patients (1,2,3,4,5,6,7,8,9,10,11,12,13,14,15,16,17,18,19,20,21,22,23,24,25,26,27,28,29 and 30) had received notification of physician availability. Findings include: 1. Review of patients 1,2,3,4,5,6,7,8,9,10,11,12,13,14,15,16,17,18,19,20,21,22,23,24,25,26,27,28,29 and 30’s electronic medical record (EMR) revealed all patients had not received written notification of a physician not being available in the hospital 24 hours a day. Interview on 4/25/24 at 11:00 a.m. with chief nursing officer B regarding patients receiving physician availability revealed she had not been aware that patients needed to have notification for that.”
-
Maintenance
The inspectors’ words, 678 words
“MAINTENANCE CFR(s): The CAH has housekeeping and preventive maintenance programs to ensure that-- (1) All essential mechanical, electrical, and patient-care equipment is maintained in safe operating condition; This Standard is not met as evidenced by: 25107 Based on observation and interview, the provider failed to implement an effective preventative maintenance plan as evidenced by: *One of one hand sink in isolation room 112 did not have a water supply. *One of one hand sink in room 106 leaked water from the drain line onto the floor. *No exhaust ventilation for bathrooms in patient rooms 102, 103/104 (with a shared bathroom), 106, 107, and 114. *Window air conditioners had a black substance covering the adjustable louvers in patient rooms 105, 106, 112, 114, the trauma room, and the emergency room. *Thirteen of 40 hand sanitizers located in the hallways outside of patient rooms for staff to sanitize their hands with were expired. Findings include: 1. Observation on 4/23/24 from 9:00 a.m. to 10:00 a.m. revealed: *The hand sink in isolation room 112 did not have a water supply. *The hand sink in room 106 leaked water from the drain line onto the floor. *There was no exhaust ventilation for bathrooms in patient rooms 102, 103/104 (with a shared bathroom), 106, 107, and 114. *Window air conditioners had a black substance covering the adjustable louvers in patient rooms 105, 106, 112, 114, the trauma room, and the emergency room. Interview on 4/25/24 at 10:20 a.m. with director of maintenance C revealed: *He had been the director of maintenance for about three months. He had been hired as a maintenance person about one year ago. *He was not aware the sink in room 112 did not have running water. *He was not aware the drain line to the sink in room 106 leaked water. *He was not aware the mechanical exhaust ventilation for the bathrooms was not working. *They cleaned the filters in the air conditioners periodically, but it was not scheduled or documented when that occurred. *They did not clean the adjustable louvers or the inside of the air conditioners. *They did not monitor the air conditioners for cleanliness. *They checked patient rooms for cleanliness of floors and walls but did not check the sinks to verify they were functional. *He had not received much training from the previous director or maintenance. *He agreed they did not have an effective preventative maintenance plan. 45683 2. Random observations on 4/23/24 from 1:45 p.m. to 2:15 p.m. in the hallways of the hospital revealed: *There were 40 Purell hand-sanitizing dispensers in the hallways of the hospital. *Each dispenser had a bottle of hand sanitizer attached to it with an expiration date printed on the front. *Thirteen of the 40 bottles of hand sanitizer observed were past their expiration date. Interview on 4/24/24 at 9:45 a.m. with housekeepers I and J regarding the expired hand sanitizer bottles in the hallways revealed: *It was their responsibility to replace the hand sanitizer bottles when they were empty. *They would have checked the level of hand sanitizer in the bottles as they cleaned throughout the day. *They were not aware there was an expiration date on the bottles. Interview on 4/24/24 at 3:00 p.m. with maintenance/environmental services/emergency preparedness director C regarding the expired hand sanitizer bottles in the hallways revealed: *The housekeeping staff were educated at general orientation to check for expired products. *He expected the hand sanitizers to have been upon expiration. *He agreed the hand sanitizer bottles were not being monitored for expiration dates. Interview on 4/25/24 at 1:40 p.m. with administrator A regarding the expired hand sanitizer bottles in the hallways revealed: *They had an over-supply of hand sanitizer left from the Covid-19 supplies they had received. *She thought it was the housekeepers’ job to monitor for expiration dates on the hand sanitizer bottles. *Sometimes other staff would have replaced the bottles when they were empty. *It was her expectation staff would discard expired products when found. *She stated they did not have a specific policy for monitoring and discarding expired hand sanitizer”
-
Governing Body Or Responsible Individual
The inspectors’ words, 235 words
“GOVERNING BODY OR RESPONSIBLE INDIVIDUAL CFR(s): The CAH has a governing body or an individual that assumes full legal responsibility for determining, implementing and monitoring policies governing the CAH’S total operation and for ensuring that those policies are administered so as to provide quality health care in a safe environment. This Standard is not met as evidenced by: 26632 Based on interview and review of the governing body By-Laws, the provider failed to ensure the original dated and signed By-Laws were available for review. Findings include: 1. Review of a copy of the governing body By-Laws provided by administrator A revealed no: *Date or signatures of the past or present governing body. *Addendums to the By-Laws. *List of the governing body members. Interview on 4/24/25 at 2:00 p.m. with administrator A revealed she was not aware she had only provided a copy of the governing body By-Laws. She stated she would bring the dated and signed By-Laws for review. Interview on 4/24/25 at 4:30 p.m. with administrator A revealed she had: *Been unable to locate the dated and signed By-Laws. *Contacted the governing body president, the administrator consultant, and the previous administrator. She stated those individuals were not aware the original signed copy was not available. *She agreed it was important to have the original dated and signed governing body By-Laws, any addendums that had been added, and changes in the governing body members available.”
-
Nursing Services
The inspectors’ words, 940 words
“NURSING SERVICES CFR(s): Nursing services must meet the needs of patients. (1) A registered nurse must provide (or assign to other personnel) the nursing care of each patient, including patients at a SNF level of care in a swing-bed CAH. The care must be provided in accordance with the patient’s needs and the specialized qualifications and competence of the staff available. This Standard is not met as evidenced by: 26632 Based on observation, interview, and policy review, the provider failed to ensure: *Outdated supplies were not available for patient use in the emergency department, room 102, and in two of three ambulances. *Outdated medications were not available for patient use in the ambulance service medication cupboard. Findings include: 1. Observation on 4/23/24 at 9:30 a.m. of supplies in room 102 revealed: *The room was set-up as a labor and delivery room. *Outdated supplies included:-Thirteen single-use packages of lubricating jelly all with the expiration date of 11/2/22. -One umbilical cord clamp expired 9/30/23. -Three of eight speculums expired 12/27/23. Interview on 4/24/24 at 9:35 a.m. with registered nurse (RN) G revealed there was no process to regularly check for outdated supplies in the labor/delivery room. 2. Observation on 4/23/24 at 10:05 a.m. in the emergency department non-trauma room revealed outdated. Those supplies included: *One of two DeLee suction catheters expired in June 2020. *One suction tubing expired on 9/1/22. *One of four Salem Sump Duel Lumen stomach tube expired on 8/31/22. *One 20 milliliter syringe expired on 2/1/22. 3. Observation on 4/24/24 at 2:05 p.m. of three of three facility owned ambulances. There were outdated supplies in two of three ambulances including: *Ambulance 1191: -One suction tubing expired on 4/12/24. -Two intravenous (IV) start kits expired in March 2024. -One I-gel airway size 2.5 expired on 3/16/24. *Ambulance 1193: -Three of three King LTS-D airways sizes 2.5 expired on 8/1/21, 5.0 expired on 1/11/21, and 3.0 expired on 2/1/23. -Two I-gel airways size 2 expired in January 2023 and size 4 expired in October 2023. -Suction tubing expired on 9/1/22. -Nasopharyngeal airway sizes 14 french and 24 french expired on 3/28/24. -Two IV start kits expired on 2/28/23. 4. Observation on 4/24/24 at 3:00 p.m. of the locked ambulance cupboard revealed three of three epinephrine injection single-dose auto injectors 0.15 milligram expired in March 2024, Interview on 4/24/24 at 3:10 p.m. with ambulance director E revealed: *Staff were assigned to different areas to check for outdated supplies and medications. *She had not realized the checks for outdated supplies was not completed. *The staff person in charge of checking for outdated medications had noted it on her checklist, but had not informed ambulance director E. 45383 5. Observation on 4/23/24 at 10:15 a.m. of supplies in the trauma room revealed: *I-gel oral airway compartment contained the following: -Size for a 25-35 kilogram (kg) patient expired on 11/2022. -Size for a 10-25 kg patient expired on 1/2023. -Size for a 5-12 kg patient expired on 3/2024. -Size for a 2-5 kg patient expired on 11/2023. *Chest tube kit contained the following: -One dry seal chest drain expired on 11/7/22. -Three 0 Perma-hand silk suture expired on 2/29/24. -Two polyline minor procedure drapes expired on 8/30/22. -Two sets of suction tubing expired on 9/1/22. -Two #15 scalpels expired on 11/31/23. -One # 15 scalpel expired on 12/31/22. -Four 20 french trocar catheters expired on 7/1/22. -One 32 french trocar catcher expired on 5/1/22. *Vital signs monitor machine contained the following: -Four packages of pediatric huggable electrodes (used to monitor the patient’s heart rate and rhythm) expired on 8/19/23. -One package of pediatric huggable electrodes expired on 10/28/23. *Airway supplies compartment contained the following: -An Ambu laryngeal mask size 5 expired on 2/5/22. -An Ambu laryngeal mask size 3 expired on 3/17/22. -One King LTS-D # 2 (laryngeal airway) expired on 11/1/22. -One Centurion alligator forcep expired on 3/31/22. *Suction machine supplies contained one Salem suction kangaroo port expired on 5/31/23. *Glide Scope (a scope used to help with endotracheal intubation) equipment contained the following: -One LoPro size 2 spectrum expired on 11/27/23. -One Mac size 4 expired on 8/27/21. -One Mac size 4 expired on 7/7/23. *Crash cart equipment contained the following: -One pediatric carbon dioxide detector expired on 3/27/24. -One Ambu carbon dioxide detector for adults expired on 3/24/24. Interview on 4/23/24 at 2:20 p.m. with chief nursing officer B regarding the removal of expired supplies revealed: *The night shift would have checked for outdated supplies on a monthly basis. *They did not have a checklist to sign off on once the task had been completed. *She had been aware that there were some outdated supplies. Review of the provider’s January 2007 Expiration Dates policy revealed: *”Two days before the end of every month the nursing staff will remove any items that will be outdated. You should pull and item that has an expiration date for the upcoming month.(example: If it is December 30, you must pull items off for January also)” *”This includes both emergency rooms, OB room, all patient rooms, nursing station, crash carts, med room, etc. The pharmacist will be in charge of all meds. Central supply will be in charge of the central supply room and IV room. We will use an expiration supply list as a reference to any items that has expiration dates, Duties are assigned as follows:” -“Day shift nursing aid will be in charge of the large ER [emergency room], nursing station and patient rooms.” -“Night shift nursing aid will be in charge of the small ER and [obstetrics] OB room.” -“Night shift Nurse will be in charge of the crash carts and med room.””
-
Records System
The inspectors’ words, 683 words
“RECORDS SYSTEM CFR(s): (1) The CAH maintains a clinical records system in accordance with written policies and procedures. This Standard is not met as evidenced by: 26632 Based on record review, interview, patient checklist review, and policy review, the provider failed to ensure 7 of 30 sampled patients (9, 14, 15, 17, 19, 21, and 22) electronic medical records (EMR) had complete information to include: discharge summaries, separate records for swing bed, and complete nursing documentation. Findings include: 1. Review of patient 15’s 4/6/24 inpatient record revealed she had been discharged to swing bed on 4/8/24. There was no physician summary for her inpatient stay. 2. Review of patient 17’s 12/3/23 inpatient record revealed he had been discharged to home on 12/4/24. There were discharge instructions given by the nurse. There was no physician discharge summary. 3. Review of patient 19’s 1/18/24 through 1/19/24 inpatient record revealed she had only one over midnight inpatient stay. She was admitted to swing bed on 1/19/24. There was no separate record started for her swing bed stay. 4. Review of patient 21’s 4/15/24 swing bed admission record revealed: *She had diagnoses that included cellulitis and a sacral ulcer. *Her admission nursing assessment indicated: *She had end stage dementia. *She had a wound on her coccyx. There were no measurements or description of this wound. *Her Braden Assessment Flowsheet indicated she had a risk factor of “Loss of appetite.” -“Patients with 1 or more Risk Factors are referred to Provider & Registered Dietitian (RD) for possible Nutrition Consult.” A yes answer was chosen. -No RD assessment was located. The nursing narrative included “1850 [6:50 p.m.] Wound assessed on EZ graph with noc [nights] shift RN [registered nurse]. See paper chart. Aquaphor applied to buttock.” 5. Review of patient 22’s 4/17/24 swing bed admission revealed: *Her initial nursing assessment indicated: -She fractures of her right patella and left upper humerous. -The Braden Assessment Flowsheet had not been completed -The dietary assessment had not been completed. -The initial wound status assessment indicated she had a blister to the lower part of her left shin. -The measurements were length 2 cm (centimeter) and width 1 cm. It was dry with no odor. -Factors that would affect wound healing was diabetes. -Her risk factor for the provider and RD to be notified for a possible consult included multiple fractures. *A 12 hour nursing assessment completed on 4/24/24 at 6:30 a.m. revealed no documentation regarding her left shin blister. *A 12 hour nursing assessment completed on 4/24/24 at 6:30 p.m. revealed 3 areas marked on an outline of a body. Those areas were: -“A” her left upper arm, “B” her right knee, and “C” her left lower calf. It indicated the wounds were from trauma, they were dry, and there was no odor. Interview on 4/25/24 at 10:10 a.m. with chief nursing officer B revealed:*They had done record reviews on the documentation of activities of daily living and baths. *No record reviews had been completed on nursing documentation. *She agreed there was missing documentation in patient’s records. 45383 6. Review of patient 9’s electronic medical record (EMR) revealed: *He: -Had been admitted on 11/7/23 with a diagnoses of agitation/delirium. -Had his brother sign his admission papers. *There was document in patiet 9’s EMR indicating who his power of attorney for healthcare was. 7. Review of patient 14’s EMR revealed: *She: -Had been admitted on 2/2/19 with diagnosis of a gastrointestinal bleed and was placed on end of life care. -Had her boyfriend sign her do not resuscitate (DNR)/do not intubate (DNI) form. *There was document in patient 14’s EMR indicating who her power of attorney for healthcare was. Interview on 4/25/23 at 11:00 a.m. regarding the location of the power of attorney for healthcare documents for patient 9 and patient 14 revealed: *She had tried to locate the documents, but was unable to locate them for patient 9 and patient 14. *She agreed that people should not sign hospital forms for patients unless they are the power of attorney for healthcare and the provider should have had copy to support their wishes.”
-
Infection Prevent Surveil & Control Of Hais
The inspectors’ words, 817 words
“INFECTION PREVENT SURVEIL & CONTROL OF HAIs CFR(s): The infection prevention and control includes surveillance, prevention, and control of HAIs, including maintaining a clean and sanitary environment to avoid sources and transmission of infection, and that the program also addresses any infection control issues identified by public health authorities; and This Standard is not met as evidenced by: 26632 Based on observation, interview, and policy review, the provider failed to ensure infection control practices were maintained for: *Hand hygiene and glove use by one of one registered nurse (RN) H and one of one physician assistant-certified (PA-C) F during care provided for patient 24. *Terminal cleaning of the floors in patient rooms with an approved disinfectant. Findings include: 1. Observation on 4/23/24 from 9:50 a.m. through 10:15 a.m. of RN H while she completed and electro-cardiogram (EKG) and placed intravenous (IV) access to patient 24 in the emergency department (ED). Those observations included: *Patient 24 was lying on an ED bed. *RN H had gloves on and completed an EKG. *She removed the EKG machine leads from patient 24 and pushed the EKG machine to the other side of the ED room. *Without changing gloves she: -Removed an uncleanable blood pressure cuff from patient 24’s right arm and placed it back in the vital sign machine basket. -Gathered supplies from the supply cabinet to obtain IV access and take blood samples. -Placed those supplies on an overbed table without placing a barrier first. -Opened the packages that contained the IV abbocath, chlorohexadine prep swab, IV site dressing, tape, and sterile gauze 4 by 4’s. -Used the chlorohexadine prep swab to disinfect the skin of patient 24’s right antecubital space. She did not swab in a back-and-forth motion for 60 seconds. She did not allow the chlorohexadine to dry prior to inserting the IV needle. -After she had obtained IV access there was blood from around the IV site. She used an alcohol wipe to wipe the blood and placed it on the overbed table. She had blood smear on her right hand thumb and first finger of her gloves. She wiped it off with the same alcohol wipe she had used to wipe the blood away from the patient’s IV access site. -She continued to fill three tubes of blood for laboratory testing. -Placed a dressing over the IV access site and taped the tubing to patient 24’s arm. -Gathered the used supplies and disposed of them. -Did not sanitize the overbed table. -Placed the blood pressure cuff on patient 24’s left arm. -Removed her gloves and without performing hand hygiene she took a pen out of her uniform pocket and placed identification stickers with the patients name on the blood tubes. Observation on 4/23/24 at 10:00 a.m. of PA-C revealed he had gloves on, used his stethoscope to listen to patient 24’s heart and lung sounds. After his physical examination, he left the room and removed his gloves, did not perform any hand hygiene, or disinfect the bell of his stethoscope, then started to document in the computer. Interview on 4/23/24 at 4:00 p.m. with RN H confirmed the above findings. She stated she gets busy and forgets to remove her gloves and perform hand hygiene between tasks. She was not sure who sanitized the EKG machine after use. She had not realized she should have placed a barrier down or sanitized the overbed table prior to placing supplies on it. Review of the provider’s last revised 6/16/22 Infection Control policy revealed: *Hand hygiene (hand washing or use of antiseptic gel or foam) should have been performed: *After handling all bodily secretions. *After removal of gloves. *Any patient care equipment should have been sanitized between uses with PDI Sani-Cloth wipes and allowed to air dry. 25107 2. Interview on 4/23/24 at 2:45 p.m. with housekeepers I and J regarding the cleaning of a room after discharge revealed they used 3M 24H 3-in1 Floor Cleaner to mop the floors of rooms after discharge. Review of the 3M 24H 3-in1 Floor Cleaner manufacturer’s instructions for use revealed the product did not have an Environmental Protection Agency registration number and made no claim to kill germs or disinfect. Interview on 4/23/24 at 3:00 p.m. with the maintenance/environmental services/emergency preparedness director C revealed housekeeping staff were to use 3M 25L HB Quat Disinfectant on the floors of rooms for terminal cleaning after a patient is discharged. Interview on 4/23/24 at 3:30 p.m. with administrator A who was also the infection preventionist for the provider revealed she agreed that floors, should have been disinfected when terminal cleaning had been completed after a patient was discharged. Review of the providers “Patient Room Terminal (Discharge/Transfer) Cleaning and Disinfection” policy dated 12/2023 revealed it did not specify what to use for mopping the floor after discharge. It stated, “Damp mop the floor starting at the far side of room and work toward the doorway.””
Apr 23, 2024: standard inspection7 deficiencies
-
Initial Comments - Not A Deficiency Citation
“A recertification survey for compliance with the Life Safety Code (LSC) (2012 existing health care occupancy) was conducted on 4/23/24. Bennett County Hospital and Nursing Home - CAH was found not in compliance with 42 CFR 485.623 (d)(1) requirements for Critical Access Hospitals. The building will meet the requirements of the 2012 LSC for existing health care occupancies upon correction of the deficiencies identified at K222, K225, K347, K363, K522, and K923 in conjunction with the provider’s commitment to continued compliance with the fire safety standards.”
-
Egress Doors
The inspectors’ words, 553 words
“Egress Doors CFR(s): NFPA 101 Egress Doors Doors in a required means of egress shall not be equipped with a latch or a lock that requires the use of a tool or key from the egress side unless using one of the following special locking arrangements: CLINICAL NEEDS OR SECURITY THREAT LOCKING Where special locking arrangements for the clinical security needs of the patient are used, only one locking device shall be permitted on each door and provisions shall be made for the rapid removal of occupants by: remote control of locks; keying of all locks or keys carried by staff at all times; or other such reliable means available to the staff at all times. 18.2.2.2.5.1, 18.2.2.2.6, 19.2.2.2.5.1, 19.2.2.2.6 SPECIAL NEEDS LOCKING ARRANGEMENTS Where special locking arrangements for the safety needs of the patient are used, all of the Clinical or Security Locking requirements are being met. In addition, the locks must be electrical locks that fail safely so as to release upon loss of power to the device; the building is protected by a supervised automatic sprinkler system and the locked space is protected by a complete smoke detection system (or is constantly monitored at an attended location within the locked space); and both the sprinkler and detection systems are arranged to unlock the doors upon activation. 18.2.2.2.5.2, 19.2.2.2.5.2, TIA 12-4 DELAYED-EGRESS LOCKING ARRANGEMENTS Approved, listed delayed-egress locking systems installed in accordance with 7.2.1.6.1 shall be permitted on door assemblies serving low and ordinary hazard contents in buildings protected throughout by an approved, supervised automatic fire detection system or an approved, supervised automatic sprinkler system. 18.2.2.2.4, 19.2.2.2.4 ACCESS-CONTROLLED EGRESS LOCKING ARRANGEMENTS Access-Controlled Egress Door assemblies installed in accordance with 7.2.1.6.2 shall be permitted. 18.2.2.2.4, 19.2.2.2.4 ELEVATOR LOBBY EXIT ACCESS LOCKING ARRANGEMENTS Elevator lobby exit access door locking in accordance with 7.2.1.6.3 shall be permitted on door assemblies in buildings protected throughout by an approved, supervised automatic fire detection system and an approved, supervised automatic sprinkler system. 18.2.2.2.4, 19.2.2.2.4 This Standard is not met as evidenced by: 18087 Based on observation and interview, the provider failed to provide egress doors as required at one location (hospital to nursing home corridor). Findings include: 1. Observation on 4/23/24 at 1:15 p.m. revealed the cross-corridor egress doors in the two-hour fire-rated wall between the hospital and the former nursing home was equipped with magnetic lock hardware. Interview with the maintenance supervisor at the time of the above observation revealed the magnetic locks were activated by one of three ‘active shooter’ panic buttons located at the hospital nurses’ station, the clinic reception desk, and computer room. He added the locks were automatically activated to lock at 5:00 p.m. daily. A key fob would be required to pass through either door. The doors were both marked as required EXITs with illuminated signs. The magnetic locks when activated nightly would prevent egress from any individual without a key fob. Interview with the maintenance supervisor at the time of the above observation confirmed that condition. He stated he was new in the position in the last six months and that there had not been any testing of the magnetic locking doors to verify that operation. Failure to provide egress doors as required increases the risk of death or injury due to fire. Ref: 2012 NFPA 101 Section 19.2.2.2.4(3), 7.2.1.6.2(3)(a)”
-
Stairways And Smokeproof Enclosures
The inspectors’ words, 155 words
“Stairways and Smokeproof Enclosures CFR(s): NFPA 101 Stairways and Smokeproof Enclosures Stairways and Smokeproof enclosures used as exits are in accordance with 7.2. 18.2.2.3, 18.2.2.4, 19.2.2.3, 19.2.2.4, 7.2 This Standard is not met as evidenced by: 18087 Based on observation, testing, and interview, the provider failed to maintain a separation one of one randomly observed stair enclosure to the second floor and lower level (corridor door was not closing to latch). Findings include: 1. Observation on 4/23/24 at 10:40 a.m. revealed the ninety-minute fire-rated door at the nurses station to the stair enclosure to the second floor and basement was equipped with spring hinges. Testing of the door at the time of the above observation revealed the door would not close to latch with the spring hinges. Interview with the maintenance supervisor at the time of the above observation confirmed that condition. The deficiency had the potential to affect 100% of the smoke enclosure occupants.”
-
Smoke Detection
The inspectors’ words, 139 words
“Smoke Detection CFR(s): NFPA 101 Smoke Detection 2012 EXISTING Smoke detection systems are provided in spaces open to corridors as required by 19.3.6.1. 19.3.4.5.2 This Standard is not met as evidenced by: 18087 Based on observation and interview, the provider failed to maintain corridor smoke monitoring of that area for one randomly observed area (south end of the patient wing) as required. Findings include: 1. Observation on 4/23/24 at 10:50 a.m. revealed the south end of the patient wing was separated at the former palliative care area by a pair of cross-corridor doors. The area was open to the required EXIT but was not equipped with any smoke detection device. Interview with the maintenance supervisor at the time of the observation confirmed that finding. The deficiency had the potential to affect 100% of the occupants of that smoke compartment.”
-
Corridor - Doors
The inspectors’ words, 519 words
“Corridor - Doors CFR(s): NFPA 101 Corridor - Doors Doors protecting corridor openings in other than required enclosures of vertical openings, exits, or hazardous areas resist the passage of smoke and are made of 1 3/4 inch solid-bonded core wood or other material capable of resisting fire for at least 20 minutes. Doors in fully sprinklered smoke compartments are only required to resist the passage of smoke. Corridor doors and doors to rooms containing flammable or combustible materials have positive latching hardware. Roller latches are prohibited by CMS regulation. These requirements do not apply to auxiliary spaces that do not contain flammable or combustible material. Clearance between bottom of door and floor covering is not exceeding 1 inch. Powered doors complying with 7.2.1.9 are permissible if provided with a device capable of keeping the door closed when a force of 5 lbf is applied. There is no impediment to the closing of the doors. Hold open devices that release when the door is pushed or pulled are permitted. Nonrated protective plates of unlimited height are permitted. Dutch doors meeting 19.3.6.3.6 are permitted. Door frames shall be labeled and made of steel or other materials in compliance with 8.3, unless the smoke compartment is sprinklered. Fixed fire window assemblies are allowed per 8.3. In sprinklered compartments there are no restrictions in area or fire resistance of glass or frames in window assemblies. 19.3.6.3, 42 CFR Parts 403, 418, 460, 482, 483, and 485 Show in REMARKS details of doors such as fire protection ratings, automatics closing devices, etc. This Standard is not met as evidenced by: 18087 A. Based on observation and interview, the provider failed to maintain impediment-free closing for one randomly observed corridor door (room 108) as required. Findings include: 1. Observation on 4/23/24 at 10:55 a.m. revealed the corridor door to patient room 108 was blocked by a Bowman dispenser (holding single-use gloves of various sizes). The room was being used to store unused walkers and wheelchairs and was full. There was no room to move the Bowman dispenser into the room. The corridor door would not be able to be closed without moving the dispenser unit. Interview with the maintenance supervisor at the time of the observation confirmed that finding. The deficiency had the potential to affect 100% of the occupants of the smoke compartment. B. Based on observation and interview, the provider failed to maintain positive latching hardware for one randomly observed corridor door (room 110 shower room) as required. Findings include: 1. Observation on 4/23/24 at 11:00 a.m. revealed the patient room 110 had two corridor doors. One door was to the provider-used main room and one door was from the shower area to the corridor. The shower area corridor door was equipped with a deadbolt which was not a positive-latching device. The room would not be separated from the corridor unless the door was closed and then the deadbolt turned into the strike plate. Interview with the maintenance supervisor at the time of the observation confirmed that finding. The deficiency had the potential to affect 100% of the occupants of the smoke compartment.”
-
Hvac - Any Heating Device
The inspectors’ words, 243 words
“HVAC - Any Heating Device CFR(s): NFPA 101 HVAC - Any Heating Device Any heating device, other than a central heating plant, is designed and installed so combustible materials cannot be ignited by device, and has a safety feature to stop fuel and shut down equipment if there is excessive temperature or ignition failure. If fuel fired, the device also: * is chimney or vent connected. * takes air for combustion from outside. * provides for a combustion system separate from occupied area atmosphere. 19.5.2.2 This Standard is not met as evidenced by: 18087 Based on observation and interview, the provider failed to maintain combustion (fresh) air in one randomly observed laundry area. Findings include: 1. Observation of the two Huebsch 165,000 btu input commercial propane gas-fired dryers in the laundry room on 4/23/24 at 10:30 a.m. revealed the following: a. There was no dedicated combustion (fresh) air ductwork provided for the operation of the two propane gas-fired commercial clothes dryers. b. A manually operated window is not acceptable for use as a combustion (fresh) air source for fuel-fired equipment. c. The corridor door to the laundry room may not be used as a source of combustion air for the dryers. This door is to be closed at all times to maintain fire separation of the laundry room. Interview with the maintenance supervisor at the time of the above observations confirmed those findings. The deficiency affected one of several requirements for fuel-fired devices.”
-
Gas Equipment - Cylinder And Container Storag
The inspectors’ words, 376 words
“Gas Equipment - Cylinder and Container Storag CFR(s): NFPA 101 Gas Equipment - Cylinder and Container Storage Greater than or equal to 3,000 cubic feet Storage locations are designed, constructed, and ventilated in accordance with 5.1.3.3.2 and 5.1.3.3.3. >300 but <3,000 cubic feet Storage locations are outdoors in an enclosure or within an enclosed interior space of non- or limited- combustible construction, with door (or gates outdoors) that can be secured. Oxidizing gases are not stored with flammables, and are separated from combustibles by 20 feet (5 feet if sprinklered) or enclosed in a cabinet of noncombustible construction having a minimum 1/2 hr. fire protection rating. Less than or equal to 300 cubic feet In a single smoke compartment, individual cylinders available for immediate use in patient care areas with an aggregate volume of less than or equal to 300 cubic feet are not required to be stored in an enclosure. Cylinders must be handled with precautions as specified in 11.6.2. A precautionary sign readable from 5 feet is on each door or gate of a cylinder storage room, where the sign includes the wording as a minimum “CAUTION: OXIDIZING GAS(ES) STORED WITHIN NO SMOKING.” Storage is planned so cylinders are used in order of which they are received from the supplier. Empty cylinders are segregated from full cylinders. When facility employs cylinders with integral pressure gauge, a threshold pressure considered empty is established. Empty cylinders are marked to avoid confusion. Cylinders stored in the open are protected from weather. 11.3.1, 11.3.2, 11.3.3, 11.3.4, 11.6.5 (NFPA 99) This Standard is not met as evidenced by: 18087 Based on observation and interview, the facility failed to ensure combustible items and oxygen concentrators were not stored within five feet of the oxygen cylinders in the storage room. Findings include: 1. Observation on 4/23/24 at 11:15 a.m. revealed combustible materials and four oxygen concentrators were found to be stored adjacent to and within five feet of oxygen cylinders in the oxygen storage room. The minimum five feet of separation between combustibles and oxygen storage was not maintained as required in this area. Interview with the maintenance supervisor at the time of the above observation confirmed that finding. The finding violated one of several requirements for the storage of oxygen.”
All 2 inspections in the last three years
| Date | Visit | What the record says |
|---|---|---|
| Apr 25, 2024 | Standard inspection | 6 deficiencies cited |
| Apr 23, 2024 | Standard inspection | 7 deficiencies cited |
How do patients fare?
- CMS gives no overall CMS rates some kinds of place from 1 to 5 stars, more stars meaning better on CMS’s own measures for that kind: for a nursing home, its health inspections, staffing and quality measures. A rating is CMS’s summary of those measures; it doesn’t promise good care. Source: CMS, Care Compare and the Five-Star Quality Rating System.: “There are too few measures or measure groups reported to calculate a star rating or measure group score.”
- CMS gives no CMS rates some kinds of place from 1 to 5 stars, more stars meaning better on CMS’s own measures for that kind: for a nursing home, its health inspections, staffing and quality measures. A rating is CMS’s summary of those measures; it doesn’t promise good care. Source: CMS, Care Compare and the Five-Star Quality Rating System.: “Results are not available for this reporting period.”
- Emergency department patients spent a median of 80 minutes there before leaving (Oct 1, 2024 to Sep 30, 2025), and 1% left before being seen.
CMS, Hospital General Information, Patient survey (HCAHPS) - Hospital, Healthcare Associated Infections - Hospital, Timely and Effective Care - Hospital and Medicare Spending Per Beneficiary - Hospital. Released Aug 13, 2026. Updated quarterly.
CMS, Complications and Deaths - Hospital and Unplanned Hospital Visits - Hospital. Released Sep 30, 2026. Updated quarterly.
| Measure | Rating |
|---|---|
| Overall ratingCMS’s overall hospital quality star rating, 1 to 5 | Not rated |
| Patient survey ratingCMS star rating from its survey of the hospital’s patients (HCAHPS), 1 to 5 | Not rated |
Is it certified, and in good standing?
- Medicare-certified critical access hospital since Jul 1, 2000.
- Ownership: voluntary non-profit - private.
- It is not accredited by a private organisation, so the state carries out its routine inspections for Medicare.
- No For hospices, home health agencies, hospitals and dialysis facilities, CMS writes deficiencies at two levels. Standard is the usual one; condition-level is the more serious, when a problem is serious enough that the provider doesn’t meet a whole condition of taking part in Medicare. Source: CMS, State Operations Manual. deficiency on record in the last three years.
- Voluntary non-profit - Private.
CMS, Provider of Services File - Hospital & Non-Hospital Facilities. Released Oct 14, 2026. Updated quarterly.
CMS, Hospital General Information. Released Aug 13, 2026. Updated quarterly.
CMS, QCOR Hospital 2567 statements of deficiencies. Released Oct 20, 2026. Updated monthly.
Has it been penalized?
- CMS doesn’t publish fines or other penalties for hospitals.
- CMS’s HAC Reduction Program file has no result for it: the program covers general acute care hospitals Medicare pays under its inpatient prospective payment system.
- None of the deficiencies cited in the last three years came from an inspection that included a complaint investigation.
CMS, Hospital-Acquired Condition (HAC) Reduction Program. Released Aug 13, 2026. Updated yearly.
CMS, Provider of Services File - Hospital & Non-Hospital Facilities. Released Oct 14, 2026. Updated quarterly.
CMS, QCOR Hospital 2567 statements of deficiencies. Released Oct 20, 2026. Updated monthly.
What do patients say about their care?
- CMS doesn’t publish staffing levels for hospitals.
CMS, Patient survey (HCAHPS) - Hospital and Timely and Effective Care - Hospital. Released Aug 13, 2026. Updated quarterly.
Who owns it?
- 8 owners or officers are people: Dale Mcdonnell (corporate director); Bradley Otte (corporate director); Jeffrey D Johnson (corporate director); Judy Soderlin (corporate officer); Timothy Huether (corporate director); David Jones (corporate director); Shandel Anson (corporate officer); Shandel Anson (runs it (operational or managerial control)).
- CMS’s Provider of Services file records 1 change of ownership, the latest on Jan 1, 2005.
- No private-equity firm among the owners CMS lists.
- No real-estate investment trust among the owners CMS lists.
CMS, Hospital All Owners and Hospital Enrollments. Released Sep 29, 2026. Updated monthly.
CMS, Provider of Services File - Hospital & Non-Hospital Facilities. Released Oct 14, 2026. Updated quarterly.
How does it compare nearby?
- No other hospital CMS lists is in Bennett County.
CMS, Hospital General Information. Released Aug 13, 2026. Updated quarterly.
What the record doesn’t say
- CMS doesn’t publish fines or other penalties for hospitals, so none are shown. The one payment cut CMS publishes for each hospital, under its Hospital-Acquired Condition Reduction Program, is shown where it applies.
- Only complaints that led to a citation appear; complaints that didn’t aren’t published.
- Most hospitals are accredited by a private organisation (The Joint Commission, DNV and others) whose routine inspections stand in for the state’s; those reports aren’t public, and QCOR holds only the state’s surveys: no inspection on record here doesn’t mean none took place.
- QCOR says its hospital inspection data are complete only through September 17, 2026, while it moves to a new system.
- CMS doesn’t publish staffing levels for hospitals.
Sources
-
Centers for Medicare & Medicaid Services, Hospital General Information (xubh-q36u).
Released Aug 13, 2026 and checked Nov 5, 2026. Updated quarterly. Public domain (U.S. Government work).
-
Centers for Medicare & Medicaid Services, Patient survey (HCAHPS) - Hospital.
Released Aug 13, 2026 and checked Nov 5, 2026. Updated quarterly. Public domain (U.S. Government work).
-
Centers for Medicare & Medicaid Services, Healthcare Associated Infections - Hospital (77hc-ibv8).
Released Aug 13, 2026 and checked Nov 5, 2026. Updated quarterly. Public domain (U.S. Government work).
-
Centers for Medicare & Medicaid Services, Complications and Deaths - Hospital (ynj2-r877).
Released Sep 30, 2026 and checked Nov 5, 2026. Updated quarterly. Public domain (U.S. Government work).
-
Centers for Medicare & Medicaid Services, Unplanned Hospital Visits - Hospital (632h-zaca).
Released Sep 30, 2026 and checked Nov 5, 2026. Updated quarterly. Public domain (U.S. Government work).
-
Centers for Medicare & Medicaid Services, Timely and Effective Care - Hospital (yv7e-xc69).
Released Aug 13, 2026 and checked Nov 5, 2026. Updated quarterly. Public domain (U.S. Government work).
-
Centers for Medicare & Medicaid Services, Medicare Spending Per Beneficiary - Hospital (rrqw-56er).
Released Aug 13, 2026 and checked Nov 5, 2026. Updated quarterly. Public domain (U.S. Government work).
-
Centers for Medicare & Medicaid Services, Hospital-Acquired Condition (HAC) Reduction Program (yq43-i98g).
Released Aug 13, 2026 and checked Nov 5, 2026. Updated yearly. Public domain (U.S. Government work).
-
Centers for Medicare & Medicaid Services, Provider of Services File - Hospital & Non-Hospital Facilities (Hospital_and_other.DATA.Q3_2026.csv).
Released Oct 14, 2026 and checked Nov 5, 2026. Updated quarterly. Public domain (U.S. Government work).
-
Centers for Medicare & Medicaid Services, QCOR Hospital 2567 statements of deficiencies (Hospital_2567s_2010_to_2026YTD.xlsx).
Released Oct 20, 2026 and checked Oct 27, 2026. Updated monthly. Public domain (U.S. Government work).
-
Centers for Medicare & Medicaid Services, Hospital All Owners (Hospital_All_Owners_2026.09.29.csv).
Released Sep 29, 2026 and checked Nov 5, 2026. Updated monthly. Public domain (U.S. Government work).
-
Centers for Medicare & Medicaid Services, Hospital Enrollments (Hospital_Enrollments_2026.09.29.csv).
Released Sep 29, 2026 and checked Nov 5, 2026. Updated monthly. Public domain (U.S. Government work).
If you believe something here is wrong, a correction starts with the agency whose record this copies: CMS. CMS’s own record is on Care Compare. If Hearth Record copied something wrongly, it will fix it and log the correction publicly, with its date: how corrections work.
This copy of the record was made on Nov 5, 2026.
From the hospital
The public record above comes first. Anything the hospital adds will appear here, below it, and say who wrote it.
Replies
None. Replies aren’t open yet. When they open, the hospital will be able to answer any finding for free, and the reply will show beside that finding, unedited and dated.
Paid listing
None. Paid listings aren’t open yet. When they open, anything paid for will say “Paid by the hospital”, and paying will never change a finding, a rating or the order of results.