Chan Soon- Shiong Medical Center at Windber

An acute care hospital in Windber, Pennsylvania 15963

600 Somerset Avenue, Windber, Pennsylvania 15963. (814) 467-3000.

CMS’s own record, on Care Compare

Watch and the shortlist are kept with a free account, on every device. Your watch list. CMS’s own record is on Care Compare.

The short answer

Record last released by CMS on Oct 20, 2026.

The last 24 months 19 deficiencies in 1 month of the last 36. Last cited Oct 2024. Most serious: Standard-level. Every month

Each figure’s source sits beside it, in its section below.

What these words mean3
Star ratings
CMS rates some kinds of place from 1 to 5 stars, more stars meaning better on CMS’s own measures for that kind: for a nursing home, its health inspections, staffing and quality measures. A rating is CMS’s summary of those measures; it doesn’t promise good care. Source: CMS, Care Compare and the Five-Star Quality Rating System.
Inspection (survey)
A visit by state inspectors, often unannounced, who check a place against the rules it must meet. For nursing homes and other places Medicare pays, CMS calls these visits surveys: a standard survey of a nursing home comes at least every 15 months, and a complaint survey whenever a complaint calls for one. Source: CMS; 42 CFR 488.308.
Deficiency, citation, violation
What inspectors write up when a place didn’t meet a rule: the rule, what they saw, and when. CMS calls it a deficiency; states may say citation or violation. It is the inspectors’ finding, not a court’s, and the place is usually asked for a plan to correct it. Source: CMS, statement of deficiencies (Form CMS-2567); each state’s licensing agency.

What did inspectors find?

The last inspection on record was on Oct 17, 2024: a standard inspection.

19 deficiencies cited in the last three years.

Source:

CMS, QCOR Hospital 2567 statements of deficiencies. Released Oct 20, 2026. Updated monthly.

When those deficiencies happened

19 deficiencies in 1 month of the last 36. Last cited Oct 2024. Most serious: Standard-level. The last 3 years, to Nov 5, 2026.

19 deficiencies by month over the last 3 years. Each cell is one month.
JanFebMarAprMayJunJulAugSepOctNovDec
2023 Dec
2024 JanFebMarAprMayJunJulAugSepOctNovDec
2025 JanFebMarAprMayJunJulAugSepOctNovDec
2026 JanFebMarAprMayJunJulAugSepOctNov

Hover or focus a month to read it.

No visit on record Visited, nothing cited A stronger orange is more serious, on its source’s own levels, read onto four bands: from the least serious it publishes to the most
Source:

Hearth Record drew this from the dates and levels in the source’s own records.

Each deficiency, as cited

Rule titles as CMS’s inspectors cite them, set in sentence case.

Source:

CMS, QCOR Hospital 2567 statements of deficiencies. Released Oct 20, 2026. Updated monthly.

Oct 17, 2024: standard inspection17 deficiencies
  • Initial Comments - Not A Deficiency Citation

    “Facility ID# 234901 Component 12 Main Building Based on a Recertification/Relicensure Survey conducted from October 15-17, 2024, it was determined that Chan Soon-Shiong Medical Center at Windber was not in compliance with the following requirements of the Life Safety Code for an existing healthcare occupancy. Compliance with the National Fire Protection Association’s Life Safety Code is required by 42 CFR 482.41(b). This is a three-story, Type II (222), fire-resistive building, that is partially sprinklered.”

    Rule K0000. Standard-level.

  • Multiple Occupancies

    The inspectors’ words, 261 words

    “Multiple Occupancies CFR(s): NFPA 101 Multiple Occupancies - Sections of Health Care Facilities Sections of health care facilities classified as other occupancies meet all of the following: o They are not intended to serve four or more inpatients for purposes of housing, treatment, or customary access. o They are separated from areas of health care occupancies by construction having a minimum two hour fire resistance rating in accordance with Chapter 8. o The entire building is protected throughout by an approved, supervised automatic sprinkler system in accordance with Section 9.7. Hospital outpatient surgical departments are required to be classified as an Ambulatory Health Care Occupancy regardless of the number of patients served. 19.1.3.3, 42 CFR 482.41, 42 CFR 485.623 This Standard is not met as evidenced by: 41378 Based on observation and interview, it was determined the facility failed to maintain a two-hour fire resistance rating to separate the healthcare occupancy from other occupancies in two instances, affecting the entire facility. Findings include: 1. Observation on October 16, 2024, revealed the following two-hour occupancy separation deficiencies: a) 9:13 a.m., observation above the occupancy separation doors, at occupational therapy on the fourth floor, revealed multiple unsealed data wires were passing through a conduit in the occupancy separation wall; b) 10:06 a.m., observation above the occupancy separation doors, at Center for Life on the fifth floor, revealed multiple unsealed data wires were passing through a conduit in the occupancy separation wall. Interview with the Maintenance Director and Maintenance Staff on October 17, 2024, at 1:30 p.m., confirmed the listed two-hour occupancy separation deficiencies.”

    Rule K0131. Standard-level.

  • Means Of Egress - General

    The inspectors’ words, 160 words

    “Means of Egress - General CFR(s): NFPA 101 Means of Egress - General Aisles, passageways, corridors, exit discharges, exit locations, and accesses are in accordance with Chapter 7, and the means of egress is continuously maintained free of all obstructions to full use in case of emergency, unless modified by 18/19.2.2 through 18/19.2.11. 18.2.1, 19.2.1, 7.1.10.1 This Standard is not met as evidenced by: 41378 Based on observation and interview, it was determined the facility failed to maintain exit access in one instance, affecting exiting in two of eleven smoke compartments. Finding included: 1. Observation on October 15, 2024, at 11:17 a.m., revealed the second-floor stairwell by the Helipad was not in compliance with NFPA 101 section 7.7.3. The exit discharge for the stairway is located on the second floor and the stairs continue uninterrupted to the first floor. Interview with the Maintenance Director and Maintenance Staff on October 17, 2024, at 1:30 p.m., confirmed the listed exit access deficiency.”

    Rule K0211. Standard-level.

  • Doors With Self-Closing Devices

    The inspectors’ words, 188 words

    “Doors with Self-Closing Devices CFR(s): NFPA 101 Doors with Self-Closing Devices Doors in an exit passageway, stairway enclosure, or horizontal exit, smoke barrier, or hazardous area enclosure are self-closing and kept in the closed position, unless held open by a release device complying with 7.2.1.8.2 that automatically closes all such doors throughout the smoke compartment or entire facility upon activation of: * Required manual fire alarm system; and * Local smoke detectors designed to detect smoke passing through the opening or a required smoke detection system; and * Automatic sprinkler system, if installed; and * Loss of power. 18.2.2.2.7, 18.2.2.2.8, 19.2.2.2.7, 19.2.2.2.8 This Standard is not met as evidenced by: 41378 Based on observation and interview, it was determined the facility failed to maintain self-closing doors in one instance, affecting one of eleven smoke compartments. Findings include: 1. Observation on October 15, 2024, at 9:56 a.m., revealed the arm was removed from the self-closing device on the pharmacy door leaving the door unable to self-close when tested. Interview with the Maintenance Director and Maintenance Staff on October 17, 2024, at 1:30 p.m., confirmed the listed self-closing door deficiency.”

    Rule K0223. Standard-level.

  • Vertical Openings - Enclosure

    The inspectors’ words, 164 words

    “Vertical Openings - Enclosure CFR(s): NFPA 101 Vertical Openings - Enclosure 2012 EXISTING Stairways, elevator shafts, light and ventilation shafts, chutes, and other vertical openings between floors are enclosed with construction having a fire resistance rating of at least 1 hour. An atrium may be used in accordance with 8.6. 19.3.1.1 through 19.3.1.6 If all vertical openings are properly enclosed with construction providing at least a 2-hour fire resistance rating, also check this box. This Standard is not met as evidenced by: 41378 Based on observation and interview, it was determined the facility failed to maintain vertical opening enclosures in one instance, affecting two of eleven smoke compartments. Findings include: 1. Observation on October 15, 2024, at 11:28 a.m. revealed the Wing Three stairwell, near the elevators on the second floor, had multiple unsealed pipe penetrations in the front wall above the door. Interview with the Maintenance Director and Maintenance Staff on October 17, 2024, at 1:30 p.m., confirmed the vertical opening enclosure deficiency.”

    Rule K0311. Standard-level.

  • Hazardous Areas - Enclosure

    The inspectors’ words, 275 words

    “Hazardous Areas - Enclosure CFR(s): NFPA 101 Hazardous Areas - Enclosure Hazardous areas are protected by a fire barrier having 1-hour fire resistance rating (with 3/4 hour fire rated doors) or an automatic fire extinguishing system in accordance with 8.7.1 or 19.3.5.9. When the approved automatic fire extinguishing system option is used, the areas shall be separated from other spaces by smoke resisting partitions and doors in accordance with 8.4. Doors shall be self-closing or automatic-closing and permitted to have nonrated or field-applied protective plates that do not exceed 48 inches from the bottom of the door. Describe the floor and zone locations of hazardous areas that are deficient in REMARKS. 19.3.2.1, 19.3.5.9 Area Automatic Sprinkler Separation N/A a. Boiler and Fuel-Fired Heater Rooms b. Laundries (larger than 100 square feet) c. Repair, Maintenance, and Paint Shops d. Soiled Linen Rooms (exceeding 64 gallons) e. Trash Collection Rooms (exceeding 64 gallons) f. Combustible Storage Rooms/Spaces (over 50 square feet) g. Laboratories (if classified as Severe Hazard - see K322) This Standard is not met as evidenced by: 41378 Based on observation and interview, it was determined the facility failed to maintain hazardous area enclosures in one instance, affecting one of eight smoke compartments. Findings include: 1. Observation on October 16, 2024, at 9:29 a.m., revealed the facility failed to maintain the required one-hour fire rating in the elevator equipment room, in the locker room hallway, on the fourth floor. There was an unsealed pipe penetration in the wall behind the elevator hydraulic pump. Interview with the Maintenance Director and Maintenance Staff on October 17, 2024, at 1:30 p.m., confirmed the listed hazardous area enclosure deficiency.”

    Rule K0321. Standard-level.

  • Fire Alarm System - Testing And Maintenance

    The inspectors’ words, 151 words

    “Fire Alarm System - Testing and Maintenance CFR(s): NFPA 101 Fire Alarm System - Testing and Maintenance A fire alarm system is tested and maintained in accordance with an approved program complying with the requirements of NFPA 70, National Electric Code, and NFPA 72, National Fire Alarm and Signaling Code. Records of system acceptance, maintenance and testing are readily available. 9.6.1.3, 9.6.1.5, NFPA 70, NFPA 72 This Standard is not met as evidenced by: 41378 Based on documentation review and interview it was determined the facility failed to perform the required semi-annual visual fire alarm system inspection, affecting the entire facility. Findings Include: 1. Review of documentation on October 17, 2024, at 9:30 a.m., revealed the facility failed to perform the required semi-annual visual fire alarm system inspection. Interview with the Maintenance Director and Maintenance Staff on October 17, 2024, at 1:30 p.m., confirmed the listed fire alarm system inspection deficiency.”

    Rule K0345. Standard-level.

  • Sprinkler System - Supervisory Signals

    The inspectors’ words, 187 words

    “Sprinkler System - Supervisory Signals CFR(s): NFPA 101 Sprinkler System - Supervisory Signals Automatic sprinkler system supervisory attachments are installed and monitored for integrity in accordance with NFPA 72, National Fire Alarm and Signaling Code, and provide a signal that sounds and is displayed at a continuously attended location or approved remote facility when sprinkler operation is impaired. 9.7.2.1, NFPA 72 This Standard is not met as evidenced by: 41378 Based on documentation review and interview, it was determined the facility failed to maintain the automatic sprinkler system in two instances, affecting the entire facility. Testing shall be in accordance with NFPA 72...14.4.5. Number 15 L (1) and (M) Findings include: 1. Review of documentation on October 17, 2024, at 9:30 a.m., revealed the facility failed to perform the following required semi-annual inspection/testing of the automatic sprinkler system: a) valve supervisory switches/tamper switch (semi-annual) 14.4.5, initiating devices (1); b) vane and pressure switch water-flow alarm devices (semi-annual) 14.4.5 initiating devices (m). Interview with the Maintenance Director and Maintenance Staff on October 17, 2024, at 1:30 p.m., confirmed the listed valve supervisory switch and water flow alarm deficiencies.”

    Rule K0352. Standard-level.

  • Sprinkler System - Maintenance And Testing

    The inspectors’ words, 402 words

    “Sprinkler System - Maintenance and Testing CFR(s): NFPA 101 Sprinkler System - Maintenance and Testing Automatic sprinkler and standpipe systems are inspected, tested, and maintained in accordance with NFPA 25, Standard for the Inspection, Testing, and Maintaining of Water-based Fire Protection Systems. Records of system design, maintenance, inspection and testing are maintained in a secure location and readily available. a) Date sprinkler system last checked _____________________ b) Who provided system test ____________________________ c) Water system supply source __________________________ Provide in REMARKS information on coverage for any non-required or partial automatic sprinkler system. 9.7.5, 9.7.7, 9.7.8, and NFPA 25 This Standard is not met as evidenced by: 41378 Based on documentation review, observation, and interview, it was determined the facility failed to maintain the automatic sprinkler system in eight instances, affecting the entire facility. Findings include: 1. Observation on October 15, 2024, revealed the following automatic sprinkler system deficiencies: The facility failed to maintain a heat/smoke resistive ceiling for the proper activation/operation of the automatic sprinkler system in the following locations: a) 10:06 a.m., there were multiple unsealed wire and pipe penetrations in the ceiling of the old security office; b) 10:09 a.m., there were multiple unsealed pipe penetrations in the ceiling of the utility closet by the pharmacy window; c) 10:19 a.m., there were multiple unsealed pipe penetrations in the ceiling of the transformer room by the ED; d) 11:01 a.m., there were multiple unsealed wire penetrations in the ceiling of the Cath Lab electrical closet located on the second floor; e) 11:11 a.m., there were multiple wires on the sprinkler branch line, above the ceiling, by the Wing Three equipment room on the second floor. Interview with the Maintenance Director and Maintenance Staff on October 17, 2024, at 1:30 p.m., confirmed the listed automatic sprinkler system deficiencies. 2. Review of documentation on October 17, 2024, at 9:30 a.m., revealed the following automatic sprinkler system inspection and testing deficiencies: a) the facility failed to perform the required annual and semi-annual sprinkler system inspections in the past twelve months; b) the facility failed to provide documentation for the required five-year internal inspection and the replacement or recalibration of gages for the automatic sprinkler system; c) the facility failed to perform the required annual fire pump inspection within the past twelve months. Interview with the Maintenance Director and Maintenance Staff on October 17, 2024, at 1:30 p.m., confirmed the listed automatic sprinkler system deficiencies.”

    Rule K0353. Standard-level.

  • Portable Fire Extinguishers

    The inspectors’ words, 206 words

    “Portable Fire Extinguishers CFR(s): NFPA 101 Portable Fire Extinguishers Portable fire extinguishers are selected, installed, inspected, and maintained in accordance with NFPA 10, Standard for Portable Fire Extinguishers. 18.3.5.12, 19.3.5.12, NFPA 10 This Standard is not met as evidenced by: 41378 Based on observation, documentation review, and interview, it was determined the facility failed to maintain portable fire extinguishers in three instances, affecting the entire facility. In accordance with NFPA 10, 7.1.2.1. Findings include: 1. Observation on October 15, 2024, at 11:45 a.m., revealed the portable fire extinguisher in the boiler room hallway was sitting on the floor unsecured. Interview with the Maintenance Director and Maintenance Staff on October 17, 2024, at 1:30 p.m., confirmed the portable fire extinguisher was on the floor and unsecured. 2. Review of documentation on October 17, 2024, at 9:30 a.m., revealed the following portable fire extinguisher inspection deficiencies: a) the facility failed to provide an annual portable fire extinguisher report; b) the facility is unable to confirm if the person/persons who performed the annual portable fire extinguisher inspection are certified to inspect portable fire extinguishers. Interview with the Maintenance Director and Maintenance Staff on October 17, 2024, at 1:30 p.m., confirmed the listed portable fire extinguisher maintenance and inspection deficiencies.”

    Rule K0355. Standard-level.

  • Subdivision Of Building Spaces - Smoke Barrie

    The inspectors’ words, 168 words

    “Subdivision of Building Spaces - Smoke Barrie CFR(s): NFPA 101 Subdivision of Building Spaces - Smoke Barrier Construction 2012 EXISTING Smoke barriers shall be constructed to a 1/2-hour fire resistance rating per 8.5. Smoke barriers shall be permitted to terminate at an atrium wall. Smoke dampers are not required in duct penetrations in fully ducted HVAC systems where an approved sprinkler system is installed for smoke compartments adjacent to the smoke barrier. 19.3.7.3, 8.6.7.1(1) Describe any mechanical smoke control system in REMARKS. This Standard is not met as evidenced by: 41378 Based on observation and interview, it was determined the facility failed to maintain smoke barrier walls in one instance, affecting two of eight smoke compartments. Findings include: 1. Observation on October 16, 2024, at 9:45 a.m., revealed there were unsealed MC cables in the smoke barrier wall inside OBGYN exam room 6, above the door. Interview with the Maintenance Director and Maintenance Staff on October 17, 2024, at 1:30 p.m., confirmed the listed smoke barrier wall deficiency.”

    Rule K0372. Standard-level.

  • Subdivision Of Building Spaces - Smoke Barrie

    The inspectors’ words, 234 words

    “Subdivision of Building Spaces - Smoke Barrie CFR(s): NFPA 101 Subdivision of Building Spaces - Smoke Barrier Doors 2012 EXISTING Doors in smoke barriers are 1-3/4-inch thick solid bonded wood-core doors or of construction that resists fire for 20 minutes. Nonrated protective plates of unlimited height are permitted. Doors are permitted to have fixed fire window assemblies per 8.5. Doors are self-closing or automatic-closing, do not require latching, and are not required to swing in the direction of egress travel. Door opening provides a minimum clear width of 32 inches for swinging or horizontal doors. 19.3.7.6, 19.3.7.8, 19.3.7.9 This Standard is not met as evidenced by: 41378 Based on observation and interview, it was determined the facility failed to maintain self-closing smoke barrier doors with a coordinating device, in two instances, affecting two of eight smoke compartments. In accordance with NFPA 80, 2010 Edition, 6.4.1.2 and 6.4.1.2.1. Findings include: 1. Observation on October 16, 2024, revealed the following smoke doors were equipped with an astragal, preventing the inactive door from closing and latching before the active door closes and latches, suggesting coordinating devices shall be used. a) 10:10 a.m., the smoke barrier doors located in PT by Center for Life; b) 10:27 a.m., the smoke barrier doors located in PT by Hospice. Interview with the Maintenance Director and Maintenance Staff on October 17, 2024, at 1:30 p.m., confirmed the listed smoke barrier door deficiencies.”

    Rule K0374. Standard-level.

  • Hvac

    The inspectors’ words, 151 words

    “HVAC CFR(s): NFPA 101 HVAC Heating, ventilation, and air conditioning shall comply with 9.2 and shall be installed in accordance with the manufacturer’s specifications. 18.5.2.1, 19.5.2.1, 9.2 This Standard is not met as evidenced by: 41378 Based on documentation review and interview, it was determined the facility failed to ensure smoke dampers were inspected within the required six-year period, affecting eight of eight smoke compartments in the facility. In accordance with NFPA 105, Standard for the Installation of Smoke Door Assemblies and Other Opening Protectives. Findings include: 1. Review of documentation on October 17, 2024, at 9:30 a.m., revealed the facility lacked documentation to indicate that smoke dampers were inspected every six years. There is no documentation available to confirm smoke damper inspection was performed within the required six-year period. Interview with the Maintenance Director and Maintenance Staff on October 17, 2024, at 1:30 p.m., confirmed the listed smoke damper deficiency.”

    Rule K0521. Standard-level.

  • Fire Drills

    The inspectors’ words, 194 words

    “Fire Drills CFR(s): NFPA 101 Fire Drills Fire drills include the transmission of a fire alarm signal and simulation of emergency fire conditions. Fire drills are held at expected and unexpected times under varying conditions, at least quarterly on each shift. The staff is familiar with procedures and is aware that drills are part of established routine. Where drills are conducted between 9:00 PM and 6:00 AM, a coded announcement may be used instead of audible alarms. 19.7.1.4 through 19.7.1.7 This Standard is not met as evidenced by: 41378 Based on documentation review and interview, it was determined the facility failed to perform four of 12 required fire drills. Findings include: 1. Review of documentation on October 17, 2024, at 9:30 a.m., revealed the facility failed to perform the following required fire drills: a) third shift in the first quarter of the year; b) second shift in the second quarter of the year; c) second shift in the fourth quarter of the year; d) third shift in the fourth quarter of the year. Interview with the Maintenance Director and Maintenance Staff on October 17, 2024, at 1:30 p.m., confirmed the listed fire drill deficiencies.”

    Rule K0712. Standard-level.

  • Electrical Systems - Receptacles

    The inspectors’ words, 165 words

    “Electrical Systems - Receptacles CFR(s): NFPA 101 Electrical Systems - Receptacles Power receptacles have at least one, separate, highly dependable grounding pole capable of maintaining low-contact resistance with its mating plug. In pediatric locations, receptacles in patient rooms, bathrooms, play rooms, and activity rooms, other than nurseries, are listed tamper-resistant or employ a listed cover. If used in patient care room, ground-fault circuit interrupters (GFCI) are listed. 6.3.2.2.6.2 (F), 6.3.2.2.4.2 (NFPA 99) This Standard is not met as evidenced by: 41378 Based on observation and interview, it was determined the facility failed to maintain electrical receptacles in two instances, affecting two of eleven smoke compartments. Findings include: 1. Observation on October 15, 2024, revealed the following electrical receptacles, within six feet of a sink, were not GFCI-protected: a) 9:53 a.m., in the Pharmacy; b) 10:31 a.m., in the staff lounge located in the Lab. Interview with the Maintenance Director and Maintenance Staff on October 17, 2024, at 1:30 p.m., confirmed the above-listed electrical receptacle deficiency.”

    Rule K0912. Standard-level.

  • Electrical Systems - Essential Electric Syste

    The inspectors’ words, 345 words

    “Electrical Systems - Essential Electric Syste CFR(s): NFPA 101 Electrical Systems - Essential Electric System Maintenance and Testing The generator or other alternate power source and associated equipment is capable of supplying service within 10 seconds. If the 10-second criterion is not met during the monthly test, a process shall be provided to annually confirm this capability for the life safety and critical branches. Maintenance and testing of the generator and transfer switches are performed in accordance with NFPA 110. Generator sets are inspected weekly, exercised under load 30 minutes 12 times a year in 20-40 day intervals, and exercised once every 36 months for 4 continuous hours. Scheduled test under load conditions include a complete simulated cold start and automatic or manual transfer of all EES loads, and are conducted by competent personnel. Maintenance and testing of stored energy power sources (Type 3 EES) are in accordance with NFPA 111. Main and feeder circuit breakers are inspected annually, and a program for periodically exercising the components is established according to manufacturer requirements. Written records of maintenance and testing are maintained and readily available. EES electrical panels and circuits are marked, readily identifiable, and separate from normal power circuits. Minimizing the possibility of damage of the emergency power source is a design consideration for new installations. 6.4.4, 6.5.4, 6.6.4 (NFPA 99), NFPA 110, NFPA 111, 700.10 (NFPA 70) This Standard is not met as evidenced by: 41378 Based on documentation review and interview, it was determined the facility failed to maintain the automatic transfer switch, in one instance, affecting the entire facility. Testing shall be in accordance with NFPA 110, 8.4.6. and NFPA 101 7.9.1.3. Findings include: 1. Review of documentation on October 17, 2024, at 9:30 a.m., revealed the facility failed to perform and document the required monthly testing/function of the automatic transfer switch, to confirm a delay of not more than ten seconds is permitted to switch to emergency power. Interview with the Maintenance Director and Maintenance Staff on October 17, 2024, at 1:30 p.m., confirmed the listed automatic transfer switch testing/function deficiency.”

    Rule K0918. Standard-level.

  • Electrical Equipment - Power Cords And Extens

    The inspectors’ words, 253 words

    “Electrical Equipment - Power Cords and Extens CFR(s): NFPA 101 Electrical Equipment - Power Cords and Extension Cords Power strips in a patient care vicinity are only used for components of movable patient-care-related electrical equipment (PCREE) assembles that have been assembled by qualified personnel and meet the conditions of 10.2.3.6. Power strips in the patient care vicinity may not be used for non-PCREE (e.g., personal electronics), except in long-term care resident rooms that do not use PCREE. Power strips for PCREE meet UL 1363A or UL 60601-1. Power strips for non-PCREE in the patient care rooms (outside of vicinity) meet UL 1363. In non-patient care rooms, power strips meet other UL standards. All power strips are used with general precautions. Extension cords are not used as a substitute for fixed wiring of a structure. Extension cords used temporarily are removed immediately upon completion of the purpose for which it was installed and meets the conditions of 10.2.4. 10.2.3.6 (NFPA 99), 10.2.4 (NFPA 99), 400-8 (NFPA 70), 590.3(D) (NFPA 70), TIA 12-5 This Standard is not met as evidenced by: 41378 Based on observation and interview, it was determined the facility failed to maintain electrical wiring systems and equipment in one instance, affecting one of eleven smoke compartments. Findings include: 1. Observation on October 15, 2024, at 9:58 a.m., revealed a microwave plugged into a power strip in patient registration room one. Interview with the Maintenance Director and Maintenance Staff on October 17, 2024, at 1:30 p.m., confirmed the listed electrical wiring systems deficiency.”

    Rule K0920. Standard-level.

Oct 4, 2024: standard inspection2 deficiencies
  • Eligibility & Process For Appt To Med Staff

    The inspectors’ words, 582 words

    “ELIGIBILITY & PROCESS FOR APPT TO MED STAFF CFR(s): 482.22(a) The medical staff must be composed of doctors of medicine or osteopathy. In accordance with State law, including scope of practice laws, the medical staff may also include other categories of physicians (as listed at §482.12(c)(1)) and non-physician practitioners who are determined to be eligible for appointment by the governing body. This Standard is not met as evidenced by: 29411 Based on review of facility documents, credential files (CF) and interview with facility staff (EMP) it was determined that the facility failed to follow adopted bylaws by failing to ensure that medical staff and allied health professionals were credentialed/privileged to practice in five of 10 credential files (CF1, CF2, CF3, CF4 and CF5). Findings include: Review of “Bylaws of the Medical Staff of Windber Medical Center” dated October 4, 2023, revealed, “... Definitions ... 6) Clinical Privileges or Privileges-Duty or permission to independently provide medical or other patient care services in the Medical Center. When an individual has clinical privileges, that individual shall have full and unrestricted access to those hospital resources which are reasonably necessary to the full exercise of the privileges, including but not limited to, all necessary hospital equipment, facilities, and personnel, except to the extent such access is limited by a restriction on the privileges imposed in accordance with these Bylaws. ... Part B. Section 1. Duration of Initial Provisional Appointment ... All initial appointments to the Medical Staff, regardless of the staff category and all initial clinical privileges are provisional from the date of the appointment until the board has acted upon a recommendation to grant or not to grant a regular appointment. At the end of the initial six-month provisional period, the practitioner’s activity will be assessed. If the practitioner’s clinical activity has not been sufficient upon which to make a determination, the provisional period may be extended to a total of 24 months (to allow for the aggregation of sufficient data on clinical activity). The appointment is then provisional up to 24 months from the initial date of appointment until the board has acted upon a recommendation to grant or not to grant a regular appointment. ... .” Review of credential file (CF1) Board of Directors most current reappointment letter dated July 7, 2022, revealed, “... You have been granted Allied Health Professionals Staff, Category I A (Independent Practitioner) privileges from 7/6/2022-6/30/2024. ... .” Review of credential file (CF2) Board of Directors most current reappointment letter dated July 7, 2022, revealed, “... You have been granted Active Medical Staff privileges in the Department of Surgery-Anesthesia, from 7/6/2022 thru 6/30/2024. ... .” Review of credential file (CF3) Board of Directors most current reappointment letter dated January 10, 2023, revealed, “... Provisional privileges are granted from 1/4/2023 to 1/4/2024 (always 12 months. ... .” Review of credential file (CF4) Board of Directors most current reappointment letter dated October 7, 2022, revealed, “... You have been granted Allied Health Professionals Staff, Category II A privileges as a Certified Physician Assistant from 10/5/2022 to 9/30/2024. ... .” Review of credential file (CF5) Board of Directors most current reappointment letter dated September 8, 2023, revealed, “... You have been granted provisional active privileges in the Department of Surgery. Your provisional privileges are granted from 9/6/2023 to 9/6/2024, (always 12 months). ... .” Interview with EMP3 and EMP4 on October 3, 2024, confirmed the above medical staff and allied health professionals lapsed in their stated appointment/reappointment and continued to attend patients.”

    Rule A0339. Standard-level.

  • Facilities, Supplies, Equipment Maintenance

    The inspectors’ words, 146 words

    “FACILITIES, SUPPLIES, EQUIPMENT MAINTENANCE CFR(s): 482.41(c)(2) Facilities, supplies, and equipment must be maintained to ensure an acceptable level of safety and quality. This Standard is not met as evidenced by: 29411 Based on review of facitlty documents and interview with facility staff (EMP) it was determined that the facility failed to ensure safe practices by failing conduct quarterly fire drills at its provider-based satellite clinics in three of eight clinics. Findings include: Request was made by surveyor to review the last four quarterly fire drills for the facility’s provider-based satellite clinics on October 1, 2024. Review of facility documentation entitled, “Educational Inservice Sign-In Sheets ... Program Title: Fire Drill off Site Draw Stations ... Fire drill performed by: ...” failed to reveal documention that a fire drill was conducted quarterly in three of eight locations. Interview with EMP1 on October 3, 2024, confirmed the above finding.”

    Rule A0724. Standard-level.

All 2 inspections in the last three years
Inspections on record
DateVisitWhat the record says
Oct 17, 2024Standard inspection17 deficiencies cited
Oct 4, 2024Standard inspection2 deficiencies cited

How do patients fare?

  • CMS’s overall for it is 2 of 5.
  • Of the measures behind its , CMS counts against the national value: mortality, 0 better and 0 worse of 3; safety of care, 0 better and 0 worse of 3; readmission, 0 better and 1 worse of 5.
  • Patients rate it 4 of 5 in CMS’s patient survey (293 surveys completed, Oct 1, 2024 to Sep 30, 2025): 78% rated it 9 or 10 out of 10, and 79% would definitely recommend it.
  • Infections, compared by CMS with the national benchmark (Oct 1, 2024 to Sep 30, 2025): C. diff infections, no different than national benchmark.
  • CMS’s patient safety composite for serious complications, PSI 90, Jul 1, 2022 to Jun 30, 2024: no different than the national value.
  • Deaths within 30 days, as CMS gives them (Jul 1, 2022 to Jun 30, 2025): heart attack 12%, heart failure 14%, pneumonia 21.1%. CMS gives no comparison with the national rate for them in this release.
  • Readmissions within 30 days, as CMS gives them (Jul 1, 2023 to Jun 30, 2025): heart attack 15.7%, heart failure 20.8%, pneumonia 16.8%, COPD 19.6%. CMS gives no comparison with the national rate for them in this release.
  • After outpatient care, compared by CMS: unplanned hospital visits after a colonoscopy, no different than the national rate.
  • Emergency department patients spent a median of 141 minutes there before leaving (Oct 1, 2024 to Sep 30, 2025), and 6% left before being seen.
  • 56% of patients with severe sepsis or septic shock got the care CMS measures, SEP-1 (Oct 1, 2024 to Sep 30, 2025).
  • Medicare’s spending per patient here is 1.02 times the national median (Jan 1, 2024 to Dec 31, 2024).
Ratings and measures, as published
MeasureRating
Overall ratingCMS’s overall hospital quality star rating, 1 to 52 of 5
Patient survey ratingCMS star rating from its survey of the hospital’s patients (HCAHPS), 1 to 54 of 5

Is it certified, and in good standing?

  • Medicare-certified acute care hospital since Oct 15, 1973.
  • Ownership: voluntary non-profit - private.
  • It is not accredited by a private organisation, so the state carries out its routine inspections for Medicare.
  • No deficiency on record in the last three years.
  • Voluntary non-profit - Private.
Source:

CMS, Provider of Services File - Hospital & Non-Hospital Facilities. Released Oct 14, 2026. Updated quarterly.

CMS, Hospital General Information. Released Aug 13, 2026. Updated quarterly.

CMS, QCOR Hospital 2567 statements of deficiencies. Released Oct 20, 2026. Updated monthly.

Has it been penalized?

  • CMS doesn’t publish fines or other penalties for hospitals.
  • Not among the hospitals whose Medicare payments CMS cut under the Hospital-Acquired Condition Reduction Program for fiscal year 2026.
  • None of the deficiencies cited in the last three years came from an inspection that included a complaint investigation.
Source:

CMS, Hospital-Acquired Condition (HAC) Reduction Program. Released Aug 13, 2026. Updated yearly.

CMS, Provider of Services File - Hospital & Non-Hospital Facilities. Released Oct 14, 2026. Updated quarterly.

CMS, QCOR Hospital 2567 statements of deficiencies. Released Oct 20, 2026. Updated monthly.

What do patients say about their care?

  • CMS doesn’t publish staffing levels for hospitals.
  • In CMS’s patient survey, patients rate how well its nurses communicated 4 of 5.
  • 78% of its health care workers got a flu shot (Oct 1, 2024 to Mar 31, 2025).
Source:

CMS, Patient survey (HCAHPS) - Hospital and Timely and Effective Care - Hospital. Released Aug 13, 2026. Updated quarterly.

Who owns it?

  • 14 owners or officers are people: Matthew L Bouch (corporate director); Charles N Kenworthy (corporate director); Thomas Kurtz (corporate officer); Thomas Kurtz (corporate director); Thomas Kurtz (managing employee (on the payroll)); Eleanor L Ramirez (corporate director); Trudi Brown (corporate officer); Trudi Brown (corporate director); Patrick Soon-Shiong (corporate director); Richard Sukenik (corporate officer); James Banaag (corporate director); David C Sachs (corporate director); Jamie R Brock (corporate officer); Robert Morse (corporate director).
  • CMS’s Provider of Services file records no change of ownership.
  • No private-equity firm among the owners CMS lists.
  • No real-estate investment trust among the owners CMS lists.
Source:

CMS, Hospital All Owners and Hospital Enrollments. Released Sep 29, 2026. Updated monthly.

CMS, Provider of Services File - Hospital & Non-Hospital Facilities. Released Oct 14, 2026. Updated quarterly.

Organisations CMS lists
OrganisationRoleShareSince
Chan Soon-Shiong Nanthealth FoundationOther role (CMS gives no detail)Jan 1, 2016
Chan Soon-Shiong Institute of Molecular Medicine LLCOther role (CMS gives no detail)Jan 1, 2016

How does it compare nearby?

  • Of the 3 hospitals CMS lists in Somerset County, 2 have an overall star rating from CMS: 1 rated 4 of 5, 1 rated 2 of 5.
  • CMS rates this one 2 of 5.
Source:

CMS, Hospital General Information. Released Aug 13, 2026. Updated quarterly.

2 compared
PlaceOverall star rating
UPMC Somerset4
Conemaugh Meyersdale Medical CenterNot given

What the record doesn’t say

  • CMS doesn’t publish fines or other penalties for hospitals, so none are shown. The one payment cut CMS publishes for each hospital, under its Hospital-Acquired Condition Reduction Program, is shown where it applies.
  • Only complaints that led to a citation appear; complaints that didn’t aren’t published.
  • Most hospitals are accredited by a private organisation (The Joint Commission, DNV and others) whose routine inspections stand in for the state’s; those reports aren’t public, and QCOR holds only the state’s surveys: no inspection on record here doesn’t mean none took place.
  • QCOR says its hospital inspection data are complete only through September 17, 2026, while it moves to a new system.
  • CMS doesn’t publish staffing levels for hospitals.
  • In its September 2026 release CMS gives no comparison with the national rate for death and readmission rates, though it gives the rates.

Sources

If you believe something here is wrong, a correction starts with the agency whose record this copies: CMS. CMS’s own record is on Care Compare. If Hearth Record copied something wrongly, it will fix it and log the correction publicly, with its date: how corrections work.

Source:

This copy of the record was made on Nov 5, 2026.

From the hospital

The public record above comes first. Anything the hospital adds will appear here, below it, and say who wrote it.

Replies

None. Replies aren’t open yet. When they open, the hospital will be able to answer any finding for free, and the reply will show beside that finding, unedited and dated.

Paid listing

None. Paid listings aren’t open yet. When they open, anything paid for will say “Paid by the hospital”, and paying will never change a finding, a rating or the order of results.

How to read a record

Four things every record does, shown on an example record made up for this guide.

An example record, made up for this guide

An example nursing home

Made up for this guide: no real place is shown

Not fully inspected in over two years (CMS flag)

11 health citations at the latest inspection cycle

The state average is 14.3.

Source:

CMS, State and US Averages and Health Deficiencies. Released Oct 28, 2026. Updated monthly.