Hearth Record

Rural Wellness Fairfax Hospital

A critical access hospital in Fairfax, Oklahoma 74637

40 Hospital Road, Fairfax, Oklahoma 74637. (918) 642-3291.

CMS’s own record, on Care Compare

Watch and the shortlist are kept with a free account, on every device. Your watch list. CMS’s own record is on Care Compare.

The short answer

Record last released by CMS on Oct 20, 2026.

The last 24 months 8 deficiencies in 2 months of the last 36. Last cited Aug 2024. Most serious: Standard-level. Every month

Each figure’s source sits beside it, in its section below.

What these words mean2
Inspection (survey)
A visit by state inspectors, often unannounced, who check a place against the rules it must meet. For nursing homes and other places Medicare pays, CMS calls these visits surveys: a standard survey of a nursing home comes at least every 15 months, and a complaint survey whenever a complaint calls for one. Source: CMS; 42 CFR 488.308.
Deficiency, citation, violation
What inspectors write up when a place didn’t meet a rule: the rule, what they saw, and when. CMS calls it a deficiency; states may say citation or violation. It is the inspectors’ finding, not a court’s, and the place is usually asked for a plan to correct it. Source: CMS, statement of deficiencies (Form CMS-2567); each state’s licensing agency.

What did inspectors find?

The last inspection on record was on Aug 7, 2024: a standard inspection.

8 deficiencies cited in the last three years.

Source:

CMS, QCOR Hospital 2567 statements of deficiencies. Released Oct 20, 2026. Updated monthly.

When those deficiencies happened

8 deficiencies in 2 months of the last 36. Last cited Aug 2024. Most serious: Standard-level. The last 3 years, to Nov 5, 2026.

8 deficiencies by month over the last 3 years. Each cell is one month.
JanFebMarAprMayJunJulAugSepOctNovDec
2023 Dec
2024 JanFebMarAprMayJunJulAugSepOctNovDec
2025 JanFebMarAprMayJunJulAugSepOctNovDec
2026 JanFebMarAprMayJunJulAugSepOctNov

Hover or focus a month to read it.

No visit on record Visited, nothing cited A stronger orange is more serious, on its source’s own levels, read onto four bands: from the least serious it publishes to the most
Source:

Hearth Record drew this from the dates and levels in the source’s own records.

Each deficiency, as cited

Rule titles as CMS’s inspectors cite them, set in sentence case.

Source:

CMS, QCOR Hospital 2567 statements of deficiencies. Released Oct 20, 2026. Updated monthly.

Aug 7, 2024: standard inspection7 deficiencies
  • Initial Comments - Not A Deficiency Citation

    “On 08/07/2024 OSDH surveyor conducted an unannounced CMS LSC survey at the Rural Wellness Hospital in Fairfax, Oklahoma. Deficiencies were cited as a result of the survey. An exit conference was conducted on 08/07/2024 with the CEO and the Plant Operations Supervisor. No other documentation was provided by the facility.”

    Rule K0000. Standard-level.

  • Hazardous Areas - Enclosure

    The inspectors’ words, 285 words

    “Hazardous Areas - Enclosure CFR(s): NFPA 101 Hazardous Areas - Enclosure Hazardous areas are protected by a fire barrier having 1-hour fire resistance rating (with 3/4 hour fire rated doors) or an automatic fire extinguishing system in accordance with 8.7.1 or 19.3.5.9. When the approved automatic fire extinguishing system option is used, the areas shall be separated from other spaces by smoke resisting partitions and doors in accordance with 8.4. Doors shall be self-closing or automatic-closing and permitted to have nonrated or field-applied protective plates that do not exceed 48 inches from the bottom of the door. Describe the floor and zone locations of hazardous areas that are deficient in REMARKS. 19.3.2.1, 19.3.5.9 Area Automatic Sprinkler Separation N/A a. Boiler and Fuel-Fired Heater Rooms b. Laundries (larger than 100 square feet) c. Repair, Maintenance, and Paint Shops d. Soiled Linen Rooms (exceeding 64 gallons) e. Trash Collection Rooms (exceeding 64 gallons) f. Combustible Storage Rooms/Spaces (over 50 square feet) g. Laboratories (if classified as Severe Hazard - see K322) This Standard is not met as evidenced by: 12713 Based on observation and staff interview, the facility failed to maintain smoke resistant ceiling in a manner that would retard the spread of smoke to adjacent areas in the event of fire. Findings: 1. During a tour of the facility on 08/07/2024, the following observation was made: a. The ceiling of the inside mechanical room (maintenance cut through) containing gas-fired boilers and/or gas-fired water heaters, was noted to have unsealed penetrations around vent pipe and gas lines exposing the wood attic space to the hazardous areas. 2. The Plant operations supervisor was present during the entire tour of the facility on 08/07/2024 and acknowledged the unsealed penetration.”

    Rule K0321. Standard-level.

  • Sprinkler System - Maintenance And Testing

    The inspectors’ words, 188 words

    “Sprinkler System - Maintenance and Testing CFR(s): NFPA 101 Sprinkler System - Maintenance and Testing Automatic sprinkler and standpipe systems are inspected, tested, and maintained in accordance with NFPA 25, Standard for the Inspection, Testing, and Maintaining of Water-based Fire Protection Systems. Records of system design, maintenance, inspection and testing are maintained in a secure location and readily available. a) Date sprinkler system last checked _____________________ b) Who provided system test ____________________________ c) Water system supply source __________________________ Provide in REMARKS information on coverage for any non-required or partial automatic sprinkler system. 9.7.5, 9.7.7, 9.7.8, and NFPA 25 This Standard is not met as evidenced by: 12713 Based on record review and staff interview, the facility failed to maintain and test a complete automatic sprinkler system. Findings: 1. The facility records were reviewed on 08/07/2024. The most recent annual sprinkler inspection document was dated 09/11/2023. A quarterly sprinkler inspection should have been performed in the fourth quarter of 2023 and the first and second quarter of 2024. 2. The Plant Operations Supervisor and the CEO stated at the exit they were not aware of the quarterly sprinkler inspection.”

    Rule K0353. Standard-level.

  • Corridor - Doors

    The inspectors’ words, 368 words

    “Corridor - Doors CFR(s): NFPA 101 Corridor - Doors Doors protecting corridor openings in other than required enclosures of vertical openings, exits, or hazardous areas resist the passage of smoke and are made of 1 3/4 inch solid-bonded core wood or other material capable of resisting fire for at least 20 minutes. Doors in fully sprinklered smoke compartments are only required to resist the passage of smoke. Corridor doors and doors to rooms containing flammable or combustible materials have positive latching hardware. Roller latches are prohibited by CMS regulation. These requirements do not apply to auxiliary spaces that do not contain flammable or combustible material. Clearance between bottom of door and floor covering is not exceeding 1 inch. Powered doors complying with 7.2.1.9 are permissible if provided with a device capable of keeping the door closed when a force of 5 lbf is applied. There is no impediment to the closing of the doors. Hold open devices that release when the door is pushed or pulled are permitted. Nonrated protective plates of unlimited height are permitted. Dutch doors meeting 19.3.6.3.6 are permitted. Door frames shall be labeled and made of steel or other materials in compliance with 8.3, unless the smoke compartment is sprinklered. Fixed fire window assemblies are allowed per 8.3. In sprinklered compartments there are no restrictions in area or fire resistance of glass or frames in window assemblies. 19.3.6.3, 42 CFR Parts 403, 418, 460, 482, 483, and 485 Show in REMARKS details of doors such as fire protection ratings, automatics closing devices, etc. This Standard is not met as evidenced by: 12713 Based on observation and interview, the facility failed to maintain corridor doors to resist the passage of smoke located in 1 of 3 smoke compartments. Findings: 1. A tour of the facility was conducted on 08/07/2024 and the following observation was made: a. The Emergency Room #1 had a roller latch to keep the door closed. 2. The Plant Operations supervisor was present during the tour of the facility and acknowledged the roller latch on the door of ER #1. Corridor doors and doors to rooms containing flammable or combustible materials have positive latching hardware. Roller latches are prohibited by CMS regulation.”

    Rule K0363. Standard-level.

  • Subdivision Of Building Spaces - Smoke Barrie

    The inspectors’ words, 191 words

    “Subdivision of Building Spaces - Smoke Barrie CFR(s): NFPA 101 Subdivision of Building Spaces - Smoke Barrier Doors 2012 EXISTING Doors in smoke barriers are 1-3/4-inch thick solid bonded wood-core doors or of construction that resists fire for 20 minutes. Nonrated protective plates of unlimited height are permitted. Doors are permitted to have fixed fire window assemblies per 8.5. Doors are self-closing or automatic-closing, do not require latching, and are not required to swing in the direction of egress travel. Door opening provides a minimum clear width of 32 inches for swinging or horizontal doors. 19.3.7.6, 19.3.7.8, 19.3.7.9 This Standard is not met as evidenced by: 12713 Based on observations and staff interview, the facility failed to maintain smoke barrier doors on 1 of 3 halls to close properly to resist the passage of smoke. Findings: 1. The smoke barrier doors between the ER and the lab area were test on 08/07/2024. These set of doors did not properly close and seal to resist the passage of smoke. 2. The Plant Operations Supervisor was present during the testing of the smoke doors and he stated he would get the doors fixed.”

    Rule K0374. Standard-level.

  • Maintenance, Inspection And Testing - Doors

    The inspectors’ words, 259 words

    “Maintenance, Inspection & Testing - Doors CFR(s): Maintenance, Inspection & Testing - Doors Fire doors assemblies are inspected and tested annually in accordance with NFPA 80, Standard for Fire Doors and Other Opening Protectives. Non-rated doors, including corridor doors to patient rooms and smoke barrier doors, are routinely inspected as part of the facility maintenance program. Individuals performing the door inspections and testing possess knowledge, training or experience that demonstrates ability. Written records of inspection and testing are maintained and are available for review. 19.7.6, 8.3.3.1 (LSC) 5.2, 5.2.3 (2010 NFPA 80) This Standard is not met as evidenced by: 12713 Based on record review and interview, the facility failed to conduct the routine inspections of the corridor doors throughout the facility. Findings 1. The facility records were reviewed on 08/07/2024 and no documentation was found to show the facility had conducted routine corridor door inspections. 2. The Plant Operations Supervisor was interviewed during the record review and he stated they do routine inspections on all doors, but they did not document the inspections. Maintenance, Inspection & Testing - Doors Fire doors assemblies are inspected and tested annually in accordance with NFPA 80, Standard for Fire Doors and Other Opening Protective’s. Non-rated doors, including corridor doors to patient rooms and smoke barrier doors, are routinely inspected as part of the facility maintenance program. Individuals performing the door inspections and testing possess knowledge, training or experience that demonstrates ability. Written records of inspection and testing are maintained and are available for review. 19.7.6, 8.3.3.1 (LSC) 5.2, 5.2.3 (2010 NFPA 80)”

    Rule K0761. Standard-level.

  • Electrical Systems - Essential Electric Syste

    The inspectors’ words, 336 words

    “Electrical Systems - Essential Electric Syste CFR(s): NFPA 101 Electrical Systems - Essential Electric System Maintenance and Testing The generator or other alternate power source and associated equipment is capable of supplying service within 10 seconds. If the 10-second criterion is not met during the monthly test, a process shall be provided to annually confirm this capability for the life safety and critical branches. Maintenance and testing of the generator and transfer switches are performed in accordance with NFPA 110. Generator sets are inspected weekly, exercised under load 30 minutes 12 times a year in 20-40 day intervals, and exercised once every 36 months for 4 continuous hours. Scheduled test under load conditions include a complete simulated cold start and automatic or manual transfer of all EES loads, and are conducted by competent personnel. Maintenance and testing of stored energy power sources (Type 3 EES) are in accordance with NFPA 111. Main and feeder circuit breakers are inspected annually, and a program for periodically exercising the components is established according to manufacturer requirements. Written records of maintenance and testing are maintained and readily available. EES electrical panels and circuits are marked, readily identifiable, and separate from normal power circuits. Minimizing the possibility of damage of the emergency power source is a design consideration for new installations. 6.4.4, 6.5.4, 6.6.4 (NFPA 99), NFPA 110, NFPA 111, 700.10 (NFPA 70) This Standard is not met as evidenced by: 12713 Based on record review and staff interview, the facility failed to conduct weekly generator inspections and testing of the generator battery as required by NFPA 99. In the event of an electrical outage, the facility could not be assured the generator would function properly. Findings 1. The facility’s records were reviewed on 08/07/2024. No documentation was found to show the facility had performed the weekly generator inspection and battery electrolyte testing for the past year. 2. The Plant Operations Supervisor was interviewed during the paper review on 08/07/2024 and he stated they have not been documenting the weekly inspection.”

    Rule K0918. Standard-level.

Jun 28, 2024: standard inspection1 deficiency
  • Licensure, Cert., Or Reg Of Personnel

    The inspectors’ words, 178 words

    “LICENSURE, CERT., OR REG OF PERSONNEL CFR(s): Staff of the CAH are licensed, certified, or registered in accordance with applicable Federal, State, and local laws and regulations. This Standard is not met as evidenced by: 41505 Based upon record review and interview the hospital failed to ensure licensure and/or registration of staff was current. This was evidenced by review of 1 of 8 (Staff L) employee files and 4 of 8 (Staff M, N, O P) contract employee files. Findings: Review of the personnel file for Staff L, a Respiratory Therapist, revealed the licensure had expired on 08/31/23. Review of contract therapist employees revealed the following: Staff N, Occupational Therapy Assistant, licensure expired 10/31/23, Staff O , Occupational Therapy Assistant, licensure expired 10/31/22, Staff P, Physical Therapy Assistant licensure expired 01/31/22. Review of the personnel file for contract Staff M revealed there failed to be evidence the licensure and/or Registration was verified. Interview on 06/28/24 at 2:20 p.m. with Staff E revealed she was not aware the licensure and/or registration of hospital staff and contract staff had expired.”

    Rule C0818. Standard-level.

All 2 inspections in the last three years
Inspections on record
DateVisitWhat the record says
Aug 7, 2024Standard inspection7 deficiencies cited
Jun 28, 2024Standard inspection1 deficiency cited

How do patients fare?

  • CMS gives no overall : “There are too few measures or measure groups reported to calculate a star rating or measure group score.”
  • CMS gives no : “The number of cases/patients is too few to report a star rating.”
  • In CMS’s patient survey (Oct 1, 2024 to Sep 30, 2025): 72% rated it 9 or 10 out of 10, and 82% would definitely recommend it.
  • Emergency department patients spent a median of 168 minutes there before leaving (Oct 1, 2024 to Sep 30, 2025), and 0% left before being seen.
Ratings and measures, as published
MeasureRating
Overall ratingCMS’s overall hospital quality star rating, 1 to 5Not rated
Patient survey ratingCMS star rating from its survey of the hospital’s patients (HCAHPS), 1 to 5Not rated

Is it certified, and in good standing?

  • Medicare-certified critical access hospital since Jul 1, 2002.
  • Ownership: proprietary.
  • It is not accredited by a private organisation, so the state carries out its routine inspections for Medicare.
  • No deficiency on record in the last three years.
  • Proprietary.
Source:

CMS, Provider of Services File - Hospital & Non-Hospital Facilities. Released Oct 14, 2026. Updated quarterly.

CMS, Hospital General Information. Released Aug 13, 2026. Updated quarterly.

CMS, QCOR Hospital 2567 statements of deficiencies. Released Oct 20, 2026. Updated monthly.

Has it been penalized?

  • CMS doesn’t publish fines or other penalties for hospitals.
  • CMS’s HAC Reduction Program file has no result for it: the program covers general acute care hospitals Medicare pays under its inpatient prospective payment system.
  • None of the deficiencies cited in the last three years came from an inspection that included a complaint investigation.
Source:

CMS, Hospital-Acquired Condition (HAC) Reduction Program. Released Aug 13, 2026. Updated yearly.

CMS, Provider of Services File - Hospital & Non-Hospital Facilities. Released Oct 14, 2026. Updated quarterly.

CMS, QCOR Hospital 2567 statements of deficiencies. Released Oct 20, 2026. Updated monthly.

What do patients say about their care?

  • CMS doesn’t publish staffing levels for hospitals.
  • 59% of its health care workers got a flu shot (Oct 1, 2024 to Mar 31, 2025).
Source:

CMS, Patient survey (HCAHPS) - Hospital and Timely and Effective Care - Hospital. Released Aug 13, 2026. Updated quarterly.

Who owns it?

  • Rural Wellness Healthcare LLC owns 100% directly since Nov 1, 2021.
  • Avem Staffing Resources, LLC and Fpfx Business Solutions, Inc. run it.
  • 5 owners or officers are people: Elizabeth J Pusey (owns 5% or more through other companies, 100%); Hunter Thoms (managing employee (on the payroll)); James I Graham (runs it (operational or managerial control)); Debi Barnard (runs it (operational or managerial control)); Ned Williams (runs it (operational or managerial control)).
  • CMS’s Provider of Services file records 3 changes of ownership, the latest on Mar 20, 2020.
  • No private-equity firm among the owners CMS lists.
  • No real-estate investment trust among the owners CMS lists.
Source:

CMS, Hospital All Owners and Hospital Enrollments. Released Sep 29, 2026. Updated monthly.

CMS, Provider of Services File - Hospital & Non-Hospital Facilities. Released Oct 14, 2026. Updated quarterly.

Organisations CMS lists
OrganisationRoleShareSince
Rural Wellness Healthcare LLCOwns 5% or more directly100%Nov 1, 2021
Rural Hospital Acquisition LLCHolds 5% or more security interest100%Feb 6, 2023
First Physicians Business SolutionsHolds 5% or more security interest100%Feb 6, 2023
Avem Staffing Resources, LLCRuns it (operational or managerial control)Feb 6, 2023
Fpfx Business Solutions, Inc.Runs it (operational or managerial control)Feb 6, 2023

How does it compare nearby?

  • Of the 2 hospitals CMS lists in Osage County, none has an overall star rating from CMS.
  • CMS gives this hospital no overall star rating to compare.
Source:

CMS, Hospital General Information. Released Aug 13, 2026. Updated quarterly.

1 compared
PlaceOverall star rating
Pawhuska Hospital, Inc.Not given

What the record doesn’t say

  • CMS doesn’t publish fines or other penalties for hospitals, so none are shown. The one payment cut CMS publishes for each hospital, under its Hospital-Acquired Condition Reduction Program, is shown where it applies.
  • Only complaints that led to a citation appear; complaints that didn’t aren’t published.
  • Most hospitals are accredited by a private organisation (The Joint Commission, DNV and others) whose routine inspections stand in for the state’s; those reports aren’t public, and QCOR holds only the state’s surveys: no inspection on record here doesn’t mean none took place.
  • QCOR says its hospital inspection data are complete only through September 17, 2026, while it moves to a new system.
  • CMS doesn’t publish staffing levels for hospitals.

Sources

If you believe something here is wrong, a correction starts with the agency whose record this copies: CMS. CMS’s own record is on Care Compare. If Hearth Record copied something wrongly, it will fix it and log the correction publicly, with its date: how corrections work.

Source:

This copy of the record was made on Nov 5, 2026.

From the hospital

The public record above comes first. Anything the hospital adds will appear here, below it, and say who wrote it.

Replies

None. Replies aren’t open yet. When they open, the hospital will be able to answer any finding for free, and the reply will show beside that finding, unedited and dated.

Paid listing

None. Paid listings aren’t open yet. When they open, anything paid for will say “Paid by the hospital”, and paying will never change a finding, a rating or the order of results.

How to read a record

Four things every record does, shown on an example record made up for this guide.

An example record, made up for this guide

An example nursing home

Made up for this guide: no real place is shown

Not fully inspected in over two years (CMS flag)

11 health citations at the latest inspection cycle

The state average is 14.3.

Source:

CMS, State and US Averages and Health Deficiencies. Released Oct 28, 2026. Updated monthly.

From the homeNone yet. Replies and paid listings aren’t open, and when they open they will sit here, below the record.

1 of 4

Every fact names its source.

Who published it, when, and how often it changes sit beside each fact, with a link to the agency’s own file.

Sign in

A free account keeps your watch list, shortlists, comparisons and saved searches on every device, and can email you when something you watch changes. Browsing never needs one.