Hearth Record

Deer Lodge Medical Center

A critical access hospital in Deer Lodge, Montana 59722

1100 Hollenback Ln, Deer Lodge, Montana 59722. (406) 846-2212.

CMS’s own record, on Care Compare

Watch and the shortlist are kept with a free account, on every device. Your watch list. CMS’s own record is on Care Compare.

The short answer

Record last released by CMS on Oct 20, 2026.

The last 24 months 15 deficiencies in 1 month of the last 36. Last cited Jan 2024. Most serious: Standard-level. Every month

Each figure’s source sits beside it, in its section below.

What these words mean2
Inspection (survey)
A visit by state inspectors, often unannounced, who check a place against the rules it must meet. For nursing homes and other places Medicare pays, CMS calls these visits surveys: a standard survey of a nursing home comes at least every 15 months, and a complaint survey whenever a complaint calls for one. Source: CMS; 42 CFR 488.308.
Deficiency, citation, violation
What inspectors write up when a place didn’t meet a rule: the rule, what they saw, and when. CMS calls it a deficiency; states may say citation or violation. It is the inspectors’ finding, not a court’s, and the place is usually asked for a plan to correct it. Source: CMS, statement of deficiencies (Form CMS-2567); each state’s licensing agency.

What did inspectors find?

The last inspection on record was on Jan 22, 2024: a standard inspection.

15 deficiencies cited in the last three years.

Source:

CMS, QCOR Hospital 2567 statements of deficiencies. Released Oct 20, 2026. Updated monthly.

When those deficiencies happened

15 deficiencies in 1 month of the last 36. Last cited Jan 2024. Most serious: Standard-level. The last 3 years, to Nov 5, 2026.

15 deficiencies by month over the last 3 years. Each cell is one month.
JanFebMarAprMayJunJulAugSepOctNovDec
2023 Dec
2024 JanFebMarAprMayJunJulAugSepOctNovDec
2025 JanFebMarAprMayJunJulAugSepOctNovDec
2026 JanFebMarAprMayJunJulAugSepOctNov

Hover or focus a month to read it.

No visit on record Visited, nothing cited A stronger orange is more serious, on its source’s own levels, read onto four bands: from the least serious it publishes to the most
Source:

Hearth Record drew this from the dates and levels in the source’s own records.

Each deficiency, as cited

Rule titles as CMS’s inspectors cite them, set in sentence case.

Source:

CMS, QCOR Hospital 2567 statements of deficiencies. Released Oct 20, 2026. Updated monthly.

Jan 22, 2024: standard inspection13 deficiencies
  • Initial Comments - Not A Deficiency Citation

    The inspectors’ words, 195 words

    “Based on the regulatory requirements and standards of 42 Code of Federal Regulations (CFR) 485.623(d) for Critical Access Hospitals (CAHs), a life safety code (LSC) recertification survey was performed on 1/24/24. Under this regulatory requirement, the facility must meet the applicable provisions of the National Fire Protection Association’s (NFPA) 101 LSC, 2012 Edition, and those mandatory Codes referenced by that edition. The facility was surveyed specifically using Chapter 19 Existing Health Care Occupancies, as well as Chapter 39 Business Occupancies. Facilities surveyed under the CAH for the Centers for Medicare and Medicaid Services (CMS) Certification Number (CCN) are as follows: 1A Main Hospital 1B Clinic and Ancillary Services Building 1A is construction Type ll (111) and contains one smoke compartment. There has been an addition to the clinic area since the last survey. The facility had 1 patient at the time of survey and has 16 licensed beds. The CAH is connected to a clinic and administration area (Building 1B) with a 2 hour separation. A horizontal exit exists between these different occupancies and some services are utilized in this non sleeping compartment occupancy. These requirements were not met as evidenced by the following deficiencies:”

    Rule K0000. Standard-level.

  • Egress Doors

    The inspectors’ words, 588 words

    “Egress Doors CFR(s): NFPA 101 Egress Doors Doors in a required means of egress shall not be equipped with a latch or a lock that requires the use of a tool or key from the egress side unless using one of the following special locking arrangements: CLINICAL NEEDS OR SECURITY THREAT LOCKING Where special locking arrangements for the clinical security needs of the patient are used, only one locking device shall be permitted on each door and provisions shall be made for the rapid removal of occupants by: remote control of locks; keying of all locks or keys carried by staff at all times; or other such reliable means available to the staff at all times. 18.2.2.2.5.1, 18.2.2.2.6, 19.2.2.2.5.1, 19.2.2.2.6 SPECIAL NEEDS LOCKING ARRANGEMENTS Where special locking arrangements for the safety needs of the patient are used, all of the Clinical or Security Locking requirements are being met. In addition, the locks must be electrical locks that fail safely so as to release upon loss of power to the device; the building is protected by a supervised automatic sprinkler system and the locked space is protected by a complete smoke detection system (or is constantly monitored at an attended location within the locked space); and both the sprinkler and detection systems are arranged to unlock the doors upon activation. 18.2.2.2.5.2, 19.2.2.2.5.2, TIA 12-4 DELAYED-EGRESS LOCKING ARRANGEMENTS Approved, listed delayed-egress locking systems installed in accordance with 7.2.1.6.1 shall be permitted on door assemblies serving low and ordinary hazard contents in buildings protected throughout by an approved, supervised automatic fire detection system or an approved, supervised automatic sprinkler system. 18.2.2.2.4, 19.2.2.2.4 ACCESS-CONTROLLED EGRESS LOCKING ARRANGEMENTS Access-Controlled Egress Door assemblies installed in accordance with 7.2.1.6.2 shall be permitted. 18.2.2.2.4, 19.2.2.2.4 ELEVATOR LOBBY EXIT ACCESS LOCKING ARRANGEMENTS Elevator lobby exit access door locking in accordance with 7.2.1.6.3 shall be permitted on door assemblies in buildings protected throughout by an approved, supervised automatic fire detection system and an approved, supervised automatic sprinkler system. 18.2.2.2.4, 19.2.2.2.4 This Standard is not met as evidenced by: 32381 Based on observation, the facility failed to ensure doors in the path of egress did not require the use of a key, a tool, or special knowledge or effort for operation from the egress side in accordance with NFPA 101-2012, Section 7.2.1.5.3, 7.2.1.5.10, and 7.2.1.6. Facilities can only lock doors and gates in the case of clinical need such as a special care unit. Findings include: 1. During an observation on 1/24/24 at 10:25 a.m., the doors leaving the recovery area were found to be maglocked, with an electronic opening push-button device marked with the universal “handicapped” symbol on the button. Entry to the recovery area was with an electronic device using a card to unlock the doors and enter. The system is set up as an “access-controlled” egress special locking arrangement. The motion detector was not a part of the system. Whatever type of special locking arrangement they want to utilize throughout the facility, either delayed egress, or access-controlled egress, the facility must then apply all the features the code requires in NFPA 101-2012 Section 7.2.1.6. The locked doors in the lighted path of egress must also unlock and be open to occupants in the event the sprinkler or fire detection systems are activated. 2. During an observation on 1/24/24 at 10:50 a.m., the back corridor to surgery had marked exit signs leading to magnetically locked doors. This was set up as an “access-controlled” egress special locking arrangement. The motion detector was not a part of the system.”

    Rule K0222. Standard-level.

  • Discharge From Exits

    The inspectors’ words, 168 words

    “Discharge from Exits CFR(s): NFPA 101 Discharge from Exits Exit discharge is arranged in accordance with 7.7, provides a level walking surface meeting the provisions of 7.1.7 with respect to changes in elevation and shall be maintained free of obstructions. Additionally, the exit discharge shall be a hard packed all-weather travel surface. 18.2.7, 19.2.7 This Standard is not met as evidenced by: 32381 Based on observation, the facility failed to assure that all exit discharges were provided with a hard surface path to the public way. Per NFPA 101, 2012 Edition, Sections 39.2.1.1, 7.1.6.2, and 7.7.1. The findings include: 1. The marked exit discharge from the dietary patio exit was examined on 1/24/24 at 9:45 a.m. The discharge ended on the patio with only a narrow gravel pathway to the the public way. 2. During an observation on 1/24/24 at 9:58 a.m., the north exit sidewalk out of the clinic was inspected. It was found to have ice and snow on the sidewalk going to the public way.”

    Rule K0271. Standard-level.

  • Exit Signage

    The inspectors’ words, 285 words

    “Exit Signage CFR(s): NFPA 101 Exit Signage 2012 EXISTING Exit and directional signs are displayed in accordance with 7.10 with continuous illumination also served by the emergency lighting system. 19.2.10.1 (Indicate N/A in one-story existing occupancies with less than 30 occupants where the line of exit travel is obvious.) This Standard is not met as evidenced by: 32381 Based on observation, the facility failed to maintain continuous illumination for all exit signs in accordance with NFPA 101, 2012 Edition, Section 7.10.5.1, failed to ensure all exit passageways were marked in accordance with NFPA 101 2012 Edition, Section 7.10.1.2.2., and failed to ensure a photo-luminescent sign was installed in accordance with NFPA 101 2012 Edition, Section 7.10.7.2. Findings include: 1. During an observation on 1/24/24 at 10:02 a.m., the clinic hall coming from the north exit was inspected. There was an exit sign in the corridor which was found to not be illuminated. It was discovered there was a paper sign inside the light which was blocking the illumination. 2. During an observation on 1/24/24 at 10:10 a.m., the exit signage in the hospital was inspected. There was no visible exit signage guiding occupants to the exits when standing near the nurses station. There was an exit sign hidden by the architecture of the area guiding occupants toward the main entrance, but it was not visible from most of the area. 3. During an observation on 1/24/24 at 10:10 a.m., there was a photo-luminescent exit sign at the end of the corridor near room 12. There was no continuous illumination of the face of the sign by a reliable light source to ensure “charging” of the sign in case of a power outage or an emergency.”

    Rule K0293. Standard-level.

  • Hazardous Areas - Enclosure

    The inspectors’ words, 252 words

    “Hazardous Areas - Enclosure CFR(s): NFPA 101 Hazardous Areas - Enclosure Hazardous areas are protected by a fire barrier having 1-hour fire resistance rating (with 3/4 hour fire rated doors) or an automatic fire extinguishing system in accordance with 8.7.1 or 19.3.5.9. When the approved automatic fire extinguishing system option is used, the areas shall be separated from other spaces by smoke resisting partitions and doors in accordance with 8.4. Doors shall be self-closing or automatic-closing and permitted to have nonrated or field-applied protective plates that do not exceed 48 inches from the bottom of the door. Describe the floor and zone locations of hazardous areas that are deficient in REMARKS. 19.3.2.1, 19.3.5.9 Area Automatic Sprinkler Separation N/A a. Boiler and Fuel-Fired Heater Rooms b. Laundries (larger than 100 square feet) c. Repair, Maintenance, and Paint Shops d. Soiled Linen Rooms (exceeding 64 gallons) e. Trash Collection Rooms (exceeding 64 gallons) f. Combustible Storage Rooms/Spaces (over 50 square feet) g. Laboratories (if classified as Severe Hazard - see K322) This Standard is not met as evidenced by: 32381 Based on observation, the facility failed to ensure hazardous rooms/areas had doors which were able to close, and latch under the power of a self-closing device, in accordance with NFPA 101, 2012 Edition, Sections 19.3.2.1 and 19.3.2.1.3. Findings include: 1. During an observation on 1/24/24 at 10:12 a.m., resident room 12 was inspected. The room was being used for storage for extra beds, 4 in total. There was no self-closing device on the door.”

    Rule K0321. Standard-level.

  • Cooking Facilities

    The inspectors’ words, 196 words

    “Cooking Facilities CFR(s): NFPA 101 Cooking Facilities Cooking equipment is protected in accordance with NFPA 96, Standard for Ventilation Control and Fire Protection of Commercial Cooking Operations, unless: * residential cooking equipment (i.e., small appliances such as microwaves, hot plates, toasters) are used for food warming or limited cooking in accordance with 18.3.2.5.2, 19.3.2.5.2 * cooking facilities open to the corridor in smoke compartments with 30 or fewer patients comply with the conditions under 18.3.2.5.3, 19.3.2.5.3, or * cooking facilities in smoke compartments with 30 or fewer patients comply with conditions under 18.3.2.5.4, 19.3.2.5.4. Cooking facilities protected according to NFPA 96 per 9.2.3 are not required to be enclosed as hazardous areas, but shall not be open to the corridor. 18.3.2.5.1 through 18.3.2.5.4, 19.3.2.5.1 through 19.3.2.5.5, 9.2.3, TIA 12-2 This Standard is not met as evidenced by: 32381 Based record review, the facility failed to maintain the wet chemical extinguishing system for the kitchen hood in accordance with NFPA 17A, 2009 Edition, Section 7.5.1. Findings include: 1. Review of the maintenance records on 1/24/24 showed the last hydro test on the main cylinder for the kitchen hood was completed in 2011 and was due in 2023.”

    Rule K0324. Standard-level.

  • Alcohol Based Hand Rub Dispenser (Abhr)

    The inspectors’ words, 241 words

    “Alcohol Based Hand Rub Dispenser (ABHR) CFR(s): NFPA 101 Alcohol Based Hand Rub Dispenser (ABHR) ABHRs are protected in accordance with 8.7.3.1, unless all conditions are met: * Corridor is at least 6 feet wide * Maximum individual dispenser capacity is 0.32 gallons (0.53 gallons in suites) of fluid and 18 ounces of Level 1 aerosols * Dispensers shall have a minimum of 4-foot horizontal spacing * Not more than an aggregate of 10 gallons of fluid or 135 ounces aerosol are used in a single smoke compartment outside a storage cabinet, excluding one individual dispenser per room * Storage in a single smoke compartment greater than 5 gallons complies with NFPA 30 * Dispensers are not installed within 1 inch of an ignition source * Dispensers over carpeted floors are in sprinklered smoke compartments * ABHR does not exceed 95 percent alcohol * Operation of the dispenser shall comply with Section 18.3.2.6(11) or 19.3.2.6(11) * ABHR is protected against inappropriate access 18.3.2.6, 19.3.2.6, 42 CFR Parts 403, 418, 460, 482, 483, and 485 This Standard is not met as evidenced by: 32381 Based on observation, the facility failed to ensure alcohol-based hand rub (ABHR) dispensers were not mounted over ignition sources in accordance with NFPA 101, 2012 Edition, Section 19.3.2.6 (8). Findings include: 1. During an observation on 1/24/24 at 10:12 a.m., resident room 12 was inspected. There was an ABHR station mounted over the light switch in the room.”

    Rule K0325. Standard-level.

  • Sprinkler System - Maintenance And Testing

    The inspectors’ words, 284 words

    “Sprinkler System - Maintenance and Testing CFR(s): NFPA 101 Sprinkler System - Maintenance and Testing Automatic sprinkler and standpipe systems are inspected, tested, and maintained in accordance with NFPA 25, Standard for the Inspection, Testing, and Maintaining of Water-based Fire Protection Systems. Records of system design, maintenance, inspection and testing are maintained in a secure location and readily available. a) Date sprinkler system last checked _____________________ b) Who provided system test ____________________________ c) Water system supply source __________________________ Provide in REMARKS information on coverage for any non-required or partial automatic sprinkler system. 9.7.5, 9.7.7, 9.7.8, and NFPA 25 This Standard is not met as evidenced by: 32381 Based on record review and observation, the facility failed to maintain the sprinkler system in accordance with NFPA 25 Standard for the Inspection, Testing, and Maintenance of Water-Based Fire Protection Systems, 2011 Edition, Section 14.2, failed to maintain the monthly gauge readings on all of the sprinkler risers per NFPA 25-2011, Sections 5.2.4.1 and 5.2.4.2, and failed to continuously maintain the sprinkler systems per NFPA 13-2010, Section 6.7.4. Findings include: 1. During a review of facility records on 1/24/24, it was found that the 5 year internal pipe inspection for the sprinkler system had not been completed on time. The last time the internal inspection had been completed was 2017. 2. During a review of facility sprinkler maintenance records it was found the facility was not documenting monthly gauge pressure readings on the wet sprinkler side, and weekly dry side pressure readings. 3. During an observation on 1/24/24 at 10:39 a.m., the drain, and test connections and valves were not identified and permanently marked with waterproof metal or rigid plastic signs at the wet and dry risers.”

    Rule K0353. Standard-level.

  • Hvac - Direct-Vent Gas Fireplaces

    The inspectors’ words, 121 words

    “HVAC - Direct-Vent Gas Fireplaces CFR(s): NFPA 101 Direct-Vent Gas Fireplaces Direct-vent gas fireplaces, as defined in NFPA 54, inside of all smoke compartments containing patient sleeping areas comply with the requirements of 18.5.2.3(2), 19.5.2.3(2). 18.5.2.3(2), 19.5.2.3(2), NFPA 54 This Standard is not met as evidenced by: 32381 Based on observation, the facility failed to ensure the installation of a direct vent fireplace met all regulatory criteria in accordance with NFPA 101 2012 Edition, Section 39.5.1, 39.5.2, 9.1, 9.2.2, and 9.8. Findings include: 1. During an observation on 1/24/24 at 10:07 a.m., the main entrance lobby was inspected. There was a direct vent gas fireplace installed in the room. There was no electronically supervised carbon monoxide detector installed in the room.”

    Rule K0524. Standard-level.

  • Fire Drills

    The inspectors’ words, 199 words

    “Fire Drills CFR(s): NFPA 101 Fire Drills Fire drills include the transmission of a fire alarm signal and simulation of emergency fire conditions. Fire drills are held at expected and unexpected times under varying conditions, at least quarterly on each shift. The staff is familiar with procedures and is aware that drills are part of established routine. Where drills are conducted between 9:00 PM and 6:00 AM, a coded announcement may be used instead of audible alarms. 19.7.1.4 through 19.7.1.7 This Standard is not met as evidenced by: 32381 Based on record review, the facility failed to ensure the fire safety plan and subsequent drills documented all requirements listed in the the code for responding to a fire drill per NFPA 101. 2012 Edition, section 19.7.1.2. Findings include: 1. Review of the facility fire drills going back a year reflected the facility lacked documentation in regards to all the elements required by code for the fire safety plan, specifically, the facility was not training staff to make a simulated emergency call to the fire department or 911. Even the system dialer will alert the monitoring agency, the code requires staff to still call 911 and report about the alarm.”

    Rule K0712. Standard-level.

  • Maintenance, Inspection And Testing - Doors

    The inspectors’ words, 193 words

    “Maintenance, Inspection & Testing - Doors CFR(s): Maintenance, Inspection & Testing - Doors Fire doors assemblies are inspected and tested annually in accordance with NFPA 80, Standard for Fire Doors and Other Opening Protectives. Non-rated doors, including corridor doors to patient rooms and smoke barrier doors, are routinely inspected as part of the facility maintenance program. Individuals performing the door inspections and testing possess knowledge, training or experience that demonstrates ability. Written records of inspection and testing are maintained and are available for review. 19.7.6, 8.3.3.1 (LSC) 5.2, 5.2.3 (2010 NFPA 80) This Standard is not met as evidenced by: 32381 Based on record review, the facility failed to test the fire doors in fire assemblies annually in accordance with NFPA 101-2012, Sections 7.2.1.15.1, 4.6.12 and in accordance with NFPA 80-2010, Section 5.2 (written report). Findings include: 1. Review of the fire safety maintenance records on 1/24/24., reflected the lack of the annual fire door assembly testing documentation. The facility must identify the required fire/smoke barriers, as well as electronically controlled doors and doors with special locking arrangement in the building and show inspections of all components of the doors in those barriers.”

    Rule K0761. Standard-level.

  • Engineer Smoke Control Systems

    The inspectors’ words, 135 words

    “Engineer Smoke Control Systems CFR(s): NFPA 101 Engineer Smoke Control Systems 2012 EXISTING When installed, engineered smoke control systems are tested in accordance with established engineering principles. Test documentation is maintained on the premises. 19.7.7 This Standard is not met as evidenced by: 32381 Based on interview, and record review the facility failed to inspect, test and document the testing and inspection of fusible link dampers in accordance with NFPA 80, Standard for Fire Door and Other Opening Protectives, 2010 Edition, Section 19.4.1.1. Findings include: During a review of facility records on 1/24/24, the fusible link dampers in the facility had not been exercised in the last six years, as there was no documentation to show they had. In an interview on 1/24/24 at 8:00 a.m., staff member B stated they had not been exercised.”

    Rule K0771. Standard-level.

  • Gas Equipment - Cylinder And Container Storag

    The inspectors’ words, 311 words

    “Gas Equipment - Cylinder and Container Storag CFR(s): NFPA 101 Gas Equipment - Cylinder and Container Storage Greater than or equal to 3,000 cubic feet Storage locations are designed, constructed, and ventilated in accordance with 5.1.3.3.2 and 5.1.3.3.3. >300 but <3,000 cubic feet Storage locations are outdoors in an enclosure or within an enclosed interior space of non- or limited- combustible construction, with door (or gates outdoors) that can be secured. Oxidizing gases are not stored with flammables, and are separated from combustibles by 20 feet (5 feet if sprinklered) or enclosed in a cabinet of noncombustible construction having a minimum 1/2 hr. fire protection rating. Less than or equal to 300 cubic feet In a single smoke compartment, individual cylinders available for immediate use in patient care areas with an aggregate volume of less than or equal to 300 cubic feet are not required to be stored in an enclosure. Cylinders must be handled with precautions as specified in 11.6.2. A precautionary sign readable from 5 feet is on each door or gate of a cylinder storage room, where the sign includes the wording as a minimum “CAUTION: OXIDIZING GAS(ES) STORED WITHIN NO SMOKING.” Storage is planned so cylinders are used in order of which they are received from the supplier. Empty cylinders are segregated from full cylinders. When facility employs cylinders with integral pressure gauge, a threshold pressure considered empty is established. Empty cylinders are marked to avoid confusion. Cylinders stored in the open are protected from weather. 11.3.1, 11.3.2, 11.3.3, 11.3.4, 11.6.5 (NFPA 99) This Standard is not met as evidenced by: 32381 Based on observation the facility failed to maintain gas cylinders per NFPA 99-2012, Section 11.6.2.3. Findings Include: 1. During an observation on 1/24/24 at 9:48 a.m., the administration area was inspected. There was a K-sized tank of helium free-standing on the floor within an office.”

    Rule K0923. Standard-level.

Jan 18, 2024: standard inspection2 deficiencies
  • Organ, Tissue, & Eye Procurement

    The inspectors’ words, 222 words

    “ORGAN, TISSUE, & EYE PROCUREMENT CFR(s): §485.643(a) Incorporate an agreement with an OPO designated under part 486 of this chapter, under which it must notify, in a timely manner, the OPO or a third party designated by the OPO of individuals whose death is imminent or who have died in the CAH. The OPO determines medical suitability for organ donation and, in the absence of alternative arrangements by the CAH, the OPO determines medical suitability for tissue and eye donation, using the definition of potential tissue and eye donor and the notification protocol developed in consultation with the tissue and eye banks identified by the CAH for this purpose; This Standard is not met as evidenced by: 47752 Based on interview and record review, the facility failed to ensure their organ, tissue, and eye donation program (OPO) was integrated into their facility’s Quality Assurance and Performance Improvement Program (QAPI). This deficient practice had the potential to affect all patients with a requested organ donor and imminent death. Findings include: During an interview and record review on 1/17/24 at 1:20 p.m., staff member G stated the facility’s OPO program was not currently included into their QAPI, and they did not have a “score card” for it. A review of the facility’s QAPI minutes showed no documentation for the inclusion of the OPO program.”

    Rule C1503. Standard-level.

  • Freedom From Abuse, Neglect & Exploitation

    The inspectors’ words, 679 words

    “FREEDOM FROM ABUSE, NEGLECT & EXPLOITATION CFR(s): Freedom from abuse, neglect and exploitation (§483.12(a)(1), (a)(2), (a)(3)(i), (a)(3)(ii), (a)(4), (b)(1), (b)(2), (c)(1), (c)(2), (c)(3), and (c)(4) of this chapter). “ §483.12(a)(1) Freedom from abuse, neglect, and exploitation. The resident has the right to be free from abuse, neglect, misappropriation of resident property, and exploitation as defined in this subpart. This includes but is not limited to freedom from corporal punishment, involuntary seclusion and any physical or chemical restraint not required to treat the resident’s medical symptoms.(a) The facility must-(1) Not use verbal, mental, sexual, or physical abuse, corporal punishment, or involuntary seclusion; “ §483.12(a)(2) Ensure that the resident is free from physical or chemical restraints imposed for purposes of discipline or convenience and that are not required to treat the resident’s medical symptoms. When the use of restraints is indicated, the facility must use the least restrictive alternative for the least amount of time and document ongoing re-evaluation of the need for restraints. “ §483.12(a)(3) Not employ or otherwise engage individuals who- (i) Have been found guilty of abuse, neglect, exploitation, misappropriation of property, or mistreatment by a court of law; (ii) Have had a finding entered into the State nurse aide registry concerning abuse, neglect, exploitation, mistreatment of residents or misappropriation of their property. “ §483.12(a)(4) Report to the State nurse aide registry or licensing authorities any knowledge it has of actions by a court of law against an employee, which would indicate unfitness for service as a nurse aide or other facility staff. “ §483.12(b) The facility must develop and implement written policies and procedures that: (1) Prohibit and prevent abuse, neglect, and exploitation of residents and misappropriation of resident property, (2) Establish policies and procedures to investigate any such allegations, “ §483.12(c) In response to allegations of abuse, neglect, exploitation, or mistreatment, the facility must: (1) Ensure that all alleged violations involving abuse, neglect, exploitation or mistreatment, including injuries of unknown source and misappropriation of resident property, are reported immediately, but not later than 2 hours after the allegation is made, if the events that cause the allegation involve abuse or result in serious bodily injury, or not later than 24 hours if the events that cause the allegation do not involve abuse and do not result in serious bodily injury, to the administrator of the facility and to other officials (including to the State Survey Agency and adult protective services where state law provides for jurisdiction in long-term care facilities) in accordance with State law through established procedures. (2) Have evidence that all alleged violations are thoroughly investigated. (3) Prevent further potential abuse, neglect, exploitation, or mistreatment while the investigation is in progress. (4) Report the results of all investigations to the administrator or his or her designated representative and to other officials in accordance with State law, including to the State Survey Agency, within 5 working days of the incident, and if the alleged violation is verified appropriate corrective action must be taken. This Standard is not met as evidenced by: 35356 Based on interview and record review, the facility failed to follow their established policies and procedures to provide on-going training to a contracted employee on the prohibition and prevention of patient abuse. This deficient practice had the potential to affect all facility contracted staff and those patients whom they provided care. Findings include: Review of the facility’s policy and procedure titled, Annual Refresher Training, last reviewed on 4/28/23, showed: - “Policy: It is the policy of [Facility] to have annual refresher training be an essential part of our plan to provide a safe workplace at [Facility]. Job specific safety training and facility wide safety training will be provided to employees through various platforms...” Review of the facility’s employee personnel files for staff member C did not show evidence of annual or additional sessions on abuse training. During an interview on 1/18/24 at 9:40 a.m., staff member GG stated staff member C was a contracted employee and they did not have an annual refresher training for abuse prohibition on file for staff member C.”

    Rule C1612. Standard-level.

All 2 inspections in the last three years
Inspections on record
DateVisitWhat the record says
Jan 22, 2024Standard inspection13 deficiencies cited
Jan 18, 2024Standard inspection2 deficiencies cited

How do patients fare?

  • CMS gives no overall : “There are too few measures or measure groups reported to calculate a star rating or measure group score.”
  • Of the measures behind its , CMS counts against the national value: mortality, 0 better and 0 worse of 1; readmission, 1 better and 0 worse of 2.
  • CMS gives no : “The number of cases/patients is too few to report a star rating.”
  • Emergency department patients spent a median of 122 minutes there before leaving (Oct 1, 2024 to Sep 30, 2025), and 0% left before being seen.
Ratings and measures, as published
MeasureRating
Overall ratingCMS’s overall hospital quality star rating, 1 to 5Not rated
Patient survey ratingCMS star rating from its survey of the hospital’s patients (HCAHPS), 1 to 5Not rated

Is it certified, and in good standing?

  • Medicare-certified critical access hospital since Sep 8, 1999.
  • Ownership: voluntary non-profit - private.
  • It is not accredited by a private organisation, so the state carries out its routine inspections for Medicare.
  • No deficiency on record in the last three years.
  • Voluntary non-profit - Private.
Source:

CMS, Provider of Services File - Hospital & Non-Hospital Facilities. Released Oct 14, 2026. Updated quarterly.

CMS, Hospital General Information. Released Aug 13, 2026. Updated quarterly.

CMS, QCOR Hospital 2567 statements of deficiencies. Released Oct 20, 2026. Updated monthly.

Has it been penalized?

  • CMS doesn’t publish fines or other penalties for hospitals.
  • CMS’s HAC Reduction Program file has no result for it: the program covers general acute care hospitals Medicare pays under its inpatient prospective payment system.
  • None of the deficiencies cited in the last three years came from an inspection that included a complaint investigation.
Source:

CMS, Hospital-Acquired Condition (HAC) Reduction Program. Released Aug 13, 2026. Updated yearly.

CMS, Provider of Services File - Hospital & Non-Hospital Facilities. Released Oct 14, 2026. Updated quarterly.

CMS, QCOR Hospital 2567 statements of deficiencies. Released Oct 20, 2026. Updated monthly.

What do patients say about their care?

  • CMS doesn’t publish staffing levels for hospitals.
  • 28% of its health care workers got a flu shot (Oct 1, 2024 to Mar 31, 2025).
Source:

CMS, Patient survey (HCAHPS) - Hospital and Timely and Effective Care - Hospital. Released Aug 13, 2026. Updated quarterly.

Who owns it?

  • 15 owners or officers are people: Jack Andersen (corporate director); Christopher Anderson (corporate director); Edward Mccarthy (corporate director); Jennifer Spring (corporate officer); Jennifer Spring (managing employee (on the payroll)); Terry Mosier (corporate director); Jaena L Richards (corporate officer); Jaena L Richards (managing employee (on the payroll)); Andrew Beck (corporate officer); Andrew Beck (managing employee (on the payroll)); Carlee Hansen (corporate director); James Decker (corporate director); Colter Cumin (corporate director); Tony Pfaff (managing employee (under contract)); Tony Pfaff (corporate officer).
  • CMS’s Provider of Services file records 1 change of ownership.
  • No private-equity firm among the owners CMS lists.
  • No real-estate investment trust among the owners CMS lists.
Source:

CMS, Hospital All Owners and Hospital Enrollments. Released Sep 29, 2026. Updated monthly.

CMS, Provider of Services File - Hospital & Non-Hospital Facilities. Released Oct 14, 2026. Updated quarterly.

How does it compare nearby?

  • No other hospital CMS lists is in Powell County.
Source:

CMS, Hospital General Information. Released Aug 13, 2026. Updated quarterly.

What the record doesn’t say

  • CMS doesn’t publish fines or other penalties for hospitals, so none are shown. The one payment cut CMS publishes for each hospital, under its Hospital-Acquired Condition Reduction Program, is shown where it applies.
  • Only complaints that led to a citation appear; complaints that didn’t aren’t published.
  • Most hospitals are accredited by a private organisation (The Joint Commission, DNV and others) whose routine inspections stand in for the state’s; those reports aren’t public, and QCOR holds only the state’s surveys: no inspection on record here doesn’t mean none took place.
  • QCOR says its hospital inspection data are complete only through September 17, 2026, while it moves to a new system.
  • CMS doesn’t publish staffing levels for hospitals.

Sources

If you believe something here is wrong, a correction starts with the agency whose record this copies: CMS. CMS’s own record is on Care Compare. If Hearth Record copied something wrongly, it will fix it and log the correction publicly, with its date: how corrections work.

Source:

This copy of the record was made on Nov 5, 2026.

From the hospital

The public record above comes first. Anything the hospital adds will appear here, below it, and say who wrote it.

Replies

None. Replies aren’t open yet. When they open, the hospital will be able to answer any finding for free, and the reply will show beside that finding, unedited and dated.

Paid listing

None. Paid listings aren’t open yet. When they open, anything paid for will say “Paid by the hospital”, and paying will never change a finding, a rating or the order of results.

How to read a record

Four things every record does, shown on an example record made up for this guide.

An example record, made up for this guide

An example nursing home

Made up for this guide: no real place is shown

Not fully inspected in over two years (CMS flag)

11 health citations at the latest inspection cycle

The state average is 14.3.

Source:

CMS, State and US Averages and Health Deficiencies. Released Oct 28, 2026. Updated monthly.

From the homeNone yet. Replies and paid listings aren’t open, and when they open they will sit here, below the record.

1 of 4

Every fact names its source.

Who published it, when, and how often it changes sit beside each fact, with a link to the agency’s own file.

Sign in

A free account keeps your watch list, shortlists, comparisons and saved searches on every device, and can email you when something you watch changes. Browsing never needs one.