Redington Fairview General Hospital
A critical access hospital in Skowhegan, Maine 04976
46 Fairview Ave PO Box 468, Skowhegan, Maine 04976. (207) 474-5121.
Watch and the shortlist are kept with a free account, on every device. Your watch list. CMS’s own record is on Care Compare.
The short answer
Record last released by CMS on Oct 20, 2026.
- 2of 5 CMS’s overall rating
- 5of 5 patient survey rating
- 11 deficiencies cited in the last three years
- 25 beds
Each figure’s source sits beside it, in its section below.
What these words mean3
- Star ratings
- CMS rates some kinds of place from 1 to 5 stars, more stars meaning better on CMS’s own measures for that kind: for a nursing home, its health inspections, staffing and quality measures. A rating is CMS’s summary of those measures; it doesn’t promise good care. Source: CMS, Care Compare and the Five-Star Quality Rating System.
- Inspection (survey)
- A visit by state inspectors, often unannounced, who check a place against the rules it must meet. For nursing homes and other places Medicare pays, CMS calls these visits surveys: a standard survey of a nursing home comes at least every 15 months, and a complaint survey whenever a complaint calls for one. Source: CMS; 42 CFR 488.308.
- Deficiency, citation, violation
- What inspectors write up when a place didn’t meet a rule: the rule, what they saw, and when. CMS calls it a deficiency; states may say citation or violation. It is the inspectors’ finding, not a court’s, and the place is usually asked for a plan to correct it. Source: CMS, statement of deficiencies (Form CMS-2567); each state’s licensing agency.
What did inspectors find?
The last inspection on record was on Aug 11, 2026: a complaint inspection.
11 deficiencies cited in the last three years.
CMS, QCOR Hospital 2567 statements of deficiencies. Released Oct 20, 2026. Updated monthly.
When those deficiencies happened
11 deficiencies in 2 months of the last 36. Last cited Aug 2026. Most serious: Standard-level. The last 3 years, to Nov 5, 2026.
| Jan | Feb | Mar | Apr | May | Jun | Jul | Aug | Sep | Oct | Nov | Dec | |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 2023 | Dec | |||||||||||
| 2024 | Jan | Feb | Mar | Apr | May | Jun | Jul | Aug | Sep | Oct | Nov | Dec |
| 2025 | Jan | Feb | Mar | Apr | May | Jun | Jul | Aug | Sep | Oct | Nov | Dec |
| 2026 | Jan | Feb | Mar | Apr | May | Jun | Jul | Aug | Sep | Oct | Nov |
Hover or focus a month to read it.
Hearth Record drew this from the dates and levels in the source’s own records.
Each deficiency, as cited
Rule titles as CMS’s inspectors cite them, set in sentence case.
CMS, QCOR Hospital 2567 statements of deficiencies. Released Oct 20, 2026. Updated monthly.
Aug 11, 2026: complaint inspection1 deficiency
-
Records System
The inspectors’ words, 327 words
“RECORDS SYSTEM CFR(s): For each patient receiving health care services, the CAH maintains a record that includes, as applicable-- (i) Identification and social data, evidence of properly executed informed consent forms, pertinent medical history, assessment of the health status and health care needs of the patient, and a brief summary of the episode, disposition, and instructions to the patient; This Standard is not met as evidenced by: 09447 Based on document review and interviews, it was determined that the facility failed to provide adequate discharge instructions in one (1) of ten (10) patient medical records. (Patient #1) Findings: Patient #1’s medical record contained the following documentation: “Activity Restrictions or Additional Instructions: There are some reports that a few tablespoons of bleach in a glass of water to use as a gargle over that area where your tooth is hurting may help...” During an interview with Manager #1 on 8/11/2026, he/she stated that the additional discharge instructions are added in the medical record by the Provider. During a telephone interview with RN#1 on 8/11/2026, he/she stated that after he/she reviewed the Additional Instructions for Patient #1, he/she questioned the directions and called MD #1 to confirm those were the instructions that MD #1 wanted him/her to give Patient #1. MD #1 confirmed that “one hundred percent (100%) those were the instructions to give (Patient #1)”. During a telephone interview with MD #1 on 8/11/2026, he/she was asked if the Additional Instructions for Patient #1 were adequately written. He/She stated yes and he/she felt the instructions were adequate. When asked if he/she felt the instructions were safe for Patient #1, he/she stated yes, “a little bleach never hurt anyone” On 08/11/2026, at approximately 2:30 PM, Manager #1 confirmed that MD #1 wrote patient instructions for Patient #1 to gargle with a solution of bleach and water that failed to include specific amounts of bleach/water. And that the instructions failed to inform Patient #1 to not swallow the solution. .”
Sep 10, 2025: standard inspection10 deficiencies
-
Initial Comments - Not A Deficiency Citation
“Federal Recertification Survey Survey Dates: 09/09/2025, 09/10/2025 Reddington Fairview General Hospital, a Critical Access Hospital, was surveyed pursuant to CFR 42 Part 482 with the National Fire Protection Association 101 Life Safety Code, 2012 Edition and is not in substantial compliance.”
-
Multiple Occupancies - Construction Type
The inspectors’ words, 588 words
“Multiple Occupancies - Construction Type CFR(s): NFPA 101 Multiple Occupancies - Construction Type Where separated occupancies are in accordance with 18/19.1.3.2 or 18/19.1.3.4, the most stringent construction type is provided throughout the building, unless a 2-hour separation is provided in accordance with 8.2.1.3, in which case the construction type is determined as follows: * The construction type and supporting construction of the health care occupancy is based on the story in which it is located in the building in accordance with 18/19.1.6 and Tables 18/19.1.6.1 * The construction type of the areas of the building enclosing the other occupancies shall be based on the applicable occupancy chapters. 18.1.3.5, 19.1.3.5, 8.2.1.3 This Standard is not met as evidenced by: 39983 Based on observations, on 09/09/2025 between 9:30 AM and 4:30 PM, surveyors in the presence of the Assistant Director of Plant Operations, the following were not met: 1. The 2-hour separation located between Mechanical room HV on Level G was penetrated by 4 electric cables inserted through the wall into the corridor above the ceiling tiles approximately six inches in diameter that was not protected by a firestop system or device in accordance with NFPA 221 (2012 edition), Standard for High Challenge Fire, section 4.9.2 Firestop Systems and Devices Required - Penetrations for cables, cable trays, conduit, pipes, tubes, combustible vents and exhaust vents, wires and similar items to accommodate electrical, mechanical, plumbing, and communications systems that pass through a wall, floor, or floor/ceiling assembly constructed as a fire barrier shall be protected by a fire stop system or device. This deficient practice could affect the Lower level G of the facility, approximately all patients/residents, all visitors, and all members of facility staff in this location(s). Surveyors confirmed these findings with the Assistant Director of Plant Operations at the time of the observation. 51948 Based on observation during the facility tour, critical access hospital failed to maintain wall construction requirements of the 2-hour separation wall per NFPA 101, Life Safety Code, 2012 Edition, Sections 8.2.1.3., and 19.1.3.5. Findings: On 09/09/2025 between 9:30 AM and 4:30 PM, surveyors in the presence of the Service Technician from the General Maintenance Department, the following were not met: 1. The 2-hour fire separation wall located in the Birthing Section, clean utility room, the backside of the exit stairwell on Level 1 the top of the wall above the ceiling tiles at the top, at the floor deck to the second floor was not firestopped. This deficient practice could affect the occupants, visitors and staff while trying to exit the building or sheltering in place. 2. The 2-hour fire separation wall located in the Medical Surgical floor, the kitchen wall on the nurse’s station side on Level 2, the top of the wall above the ceiling tiles, the wall did not go all the way to the roof deck, and it was not firestopped. This deficient practice could affect the occupants, visitors and staff while trying to exit the building or sheltering in place. 3. The 2-hour fire separation wall located on the Medical Surgical floor, the wall next to the kitchen entry by the nurse’s station on Level 2 the top of the wall above the ceiling tiles, a non-rated spray foam was used in place of firestopping in various spots along the wall. This deficient practice could affect the occupants, visitors and staff while trying to exit the building or sheltering in place. Surveyors confirmed these findings with the Service Technician from the General Maintenance Department at the time of the observation.”
-
Means Of Egress - General
The inspectors’ words, 218 words
“Means of Egress - General CFR(s): NFPA 101 Means of Egress - General Aisles, passageways, corridors, exit discharges, exit locations, and accesses are in accordance with Chapter 7, and the means of egress is continuously maintained free of all obstructions to full use in case of emergency, unless modified by 18/19.2.2 through 18/19.2.11. 18.2.1, 19.2.1, 7.1.10.1 This Standard is not met as evidenced by: 50034 Federal Recertification Survey: Date: 09/09/2025 Based on observation, the critical access hospital failed to maintain the Exit Corridor required width in egress corridors per NFPA 101, Life Safety Code, 2012 Edition, Sections 18.2.1, 19.2.1, 7.1.10.1. This deficient practice could affect patients, staff, family members and general public trying to egress in an emergency. Findings: During a facility tour between the hours of 9:30 AM and 4:30 PM, a surveyor with the Service Technician present observed the following: 1. In the corridors located on the Medical Surgical Unit by Patient Rooms 208, 214, 219 and 226 there are trash cans located in the corridor. 2. In the corridors located in the Medical Surgical Unit by Patient Rooms 214 and 219 there are portable nurse carts plugged into the wall and were stationary and unattended for more that 30 minutes. This findings were confirmed by the surveyor and Service Technician at the time of observation.”
-
Number Of Exits - Corridors
The inspectors’ words, 239 words
“Number of Exits - Corridors CFR(s): NFPA 101 Number of Exits - Corridors Every corridor shall provide access to not less than two approved exits in accordance with Sections 7.4 and 7.5 without passing through any intervening rooms or spaces other than corridors or lobbies. 18.2.5.4, 19.2.5.4 This Standard is not met as evidenced by: 51948 Based on observation and interview, the critical access hospital failed to meet the requirements of the National Fire Protection Association (NFPA) 101, Life Safety Code, 2012 edition for number of means of egress in accordance with 7.4.1.1. Finding: On 09/09/2025 between 9:30 AM and 4:30 PM, surveyors in the presence of the Service Technician from the General Maintenance Department, the following were not met: 1. In the Birthing Section on Level 1, the space only had one marked means of egress. I interviewed the birthing supervisor, and she stated that the one egress to the exit stairwell was the means of egress. I asked if they would exit through the Operating Room to the second exit stairwell. The supervisor stated they do not exit through the Operating Room. There were no exit signs marking any exit through to Operating Room in the birthing space. This deficient practice could affect the occupants, visitors and staff while trying to exit the building or sheltering in place. Surveyors confirmed this finding with the Service Technician from the General Maintenance Department at the time of the observation.”
-
Sprinkler System - Installation
The inspectors’ words, 249 words
“Sprinkler System - Installation CFR(s): NFPA 101 Spinkler System - Installation 2012 EXISTING Nursing homes, and hospitals where required by construction type, are protected throughout by an approved automatic sprinkler system in accordance with NFPA 13, Standard for the Installation of Sprinkler Systems. In Type I and II construction, alternative protection measures are permitted to be substituted for sprinkler protection in specific areas where state or local regulations prohibit sprinklers. In hospitals, sprinklers are not required in clothes closets of patient sleeping rooms where the area of the closet does not exceed 6 square feet and sprinkler coverage covers the closet footprint as required by NFPA 13, Standard for Installation of Sprinkler Systems. 19.3.5.1, 19.3.5.2, 19.3.5.3, 19.3.5.4, 19.3.5.5, 19.4.2, 19.3.5.10, 9.7, 9.7.1.1(1) This Standard is not met as evidenced by: 39983 Based on observation, the Hospital failed to install the water-based fire protection system throughout the premises in accordance with NFPA 13, Standard for the Installation of Sprinkler Systems, 2010 edition, Sections 8.1.1(1), and 8.15.10(3) as referenced by NFPA 101, Life Safety Code, 2012 edition, Section 19.3.5. Findings: On 09/09/2025, between 09:30 AM and 4:30 PM, surveyors with the Assistant Director of Plant Operations present, observed the following: 1. The Kitchen paper supply closet located across from the preparation kitchen does not have any sprinkler coverage. This deficient practice could effect all staff, visitors and, patients located on the Ground level G. Surveyors confirmed these findings with the Assistant Director of Plant Operations at the time of the observation.”
-
Sprinkler System - Maintenance And Testing
The inspectors’ words, 268 words
“Sprinkler System - Maintenance and Testing CFR(s): NFPA 101 Sprinkler System - Maintenance and Testing Automatic sprinkler and standpipe systems are inspected, tested, and maintained in accordance with NFPA 25, Standard for the Inspection, Testing, and Maintaining of Water-based Fire Protection Systems. Records of system design, maintenance, inspection and testing are maintained in a secure location and readily available. a) Date sprinkler system last checked _____________________ b) Who provided system test ____________________________ c) Water system supply source __________________________ Provide in REMARKS information on coverage for any non-required or partial automatic sprinkler system. 9.7.5, 9.7.7, 9.7.8, and NFPA 25 This Standard is not met as evidenced by: 50034 Based on observation and record review, the long-term care facility failed to ensure that Automatic sprinkler and standpipe systems are inspected, tested, and maintained in accordance with 2011 NFPA 25, Standard for the Inspection, Testing, and Maintaining of Water-based Fire Protection Systems sections 5.3.3.2 and 5.3.3.3. This deficient practice could cause the sprinkler system to not function properly and affect residents, staff, family members and general members of the public. Findings: During a record review of documentation on 09-09-2025 between the hours of 9:30 AM and 4:30 PM a surveyor with the Director of Plant Operations observed the following: 1. Documents of the most recent Sprinkler Inspection/Testing Report indicate the Wet Riser Flow Switch in the food storage room and the Wet Switch in the phone room need an inspectors test valve piped in to a drain to properly test flow switch. These findings were confirmed by the surveyor and the Director of Plant Operations at the time of record review.”
-
Corridor - Doors
The inspectors’ words, 416 words
“Corridor - Doors CFR(s): NFPA 101 Corridor - Doors Doors protecting corridor openings in other than required enclosures of vertical openings, exits, or hazardous areas resist the passage of smoke and are made of 1 3/4 inch solid-bonded core wood or other material capable of resisting fire for at least 20 minutes. Doors in fully sprinklered smoke compartments are only required to resist the passage of smoke. Corridor doors and doors to rooms containing flammable or combustible materials have positive latching hardware. Roller latches are prohibited by CMS regulation. These requirements do not apply to auxiliary spaces that do not contain flammable or combustible material. Clearance between bottom of door and floor covering is not exceeding 1 inch. Powered doors complying with 7.2.1.9 are permissible if provided with a device capable of keeping the door closed when a force of 5 lbf is applied. There is no impediment to the closing of the doors. Hold open devices that release when the door is pushed or pulled are permitted. Nonrated protective plates of unlimited height are permitted. Dutch doors meeting 19.3.6.3.6 are permitted. Door frames shall be labeled and made of steel or other materials in compliance with 8.3, unless the smoke compartment is sprinklered. Fixed fire window assemblies are allowed per 8.3. In sprinklered compartments there are no restrictions in area or fire resistance of glass or frames in window assemblies. 19.3.6.3, 42 CFR Parts 403, 418, 460, 482, 483, and 485 Show in REMARKS details of doors such as fire protection ratings, automatics closing devices, etc. This Standard is not met as evidenced by: 51948 Based on observation the critical care hospital failed to maintain the corridor door from closing and positively latching per NFPA 101, Life Safety Code, 2012 Edition, Sections 19.3.6.3, 19.3.6.3.5. Findings: On 09/09/2025 between 9:30 AM and 4:30 PM, surveyors in the presence of the Service Technician from the General Maintenance Department, the following were not met: 1. In the Operating Section on level 1, the equipment room corridor doors, both leaf’s at the top and bottom, the flush bolts did not latch when closed. 2. In the Endoscopy Section on Level 1, the entrance corridor doors, both leaf’s at the top and bottom, the flush bolts did not latch when closed. This deficient practice could affect the occupants, visitors and staff while trying to exit the building or sheltering in place. Surveyors confirmed these findings with the Service Technician from the General Maintenance Department at the time of the observation.”
-
Subdivision Of Building Spaces - Smoke Compar
The inspectors’ words, 511 words
“Subdivision of Building Spaces - Smoke Compar CFR(s): NFPA 101 Subdivision of Building Spaces - Smoke Compartments 2012 EXISTING Smoke barriers shall be provided to form at least two smoke compartments on every sleeping floor with a 30 or more patient bed capacity. Size of compartments cannot exceed 22,500 square feet or a 200-foot travel distance from any point in the compartment to a door in the smoke barrier. 19.3.7.1, 19.3.7.2 Detail in REMARKS zone dimensions including length of zones and dead-end corridors. This Standard is not met as evidenced by: 39983 1. Observation during a facility tour with the Assistant Director of Plant Operations on 09/09/25 between 9:30 AM and 4:30 PM indicated that a smoke barrier located at the Emergency Department entrance on Level G, did not fully extend beyond the ceiling. The interstitial space was not protected on the bottom by a construction assembly providing smoke resistance equivalent to a smoke barrier. This is not in accordance with the requirement of National Fire Protection Association (NFPA) 101, Life Safety Code, 2012 edition, section 8.5.2.2. Smoke barriers shall be continuous through all concealed spaces, such as those above a ceiling, including interstitial spaces. This deficient practice could affect the lower level G of the facility, approximately all patients/residents on level G, all visitors, and all members of facility staff in this location(s). 2. Observation during a facility tour with the Assistant Director of Plant Operations on 09/09/25 between 9:30 AM and 4:30 PM indicated that a smoke barrier located above the entrance from the Emergency Department registration back hallway was penetrated by electrical conduit pipe and conduit that were not properly sealed and would allow the passage of smoke from one smoke compartment to another. This is not in accordance with the requirement of National Fire Protection Association (NFPA) 101, Life Safety Code, 2012 edition, section 8.5.6.2 Penetrations for .... shall be protected by a system or material capable of resisting the transfer of smoke. This deficient practice could affect the lower level G of the facility, approximately all patients/residents on level G, all visitors, and all members of facility staff in this location(s). Surveyors confirmed these findings with the Assistant Director of Plant Operations at the time of the observation. 51948 Based on observation the critical access hospital failed to meet the requirements of the National Fire Protection Association (NFPA) 101, Life Safety Code, 2012 edition for smoke barrier enclosures in accordance with 19.3.7.3. Finding: On 09/09/2025 between 9:30 AM and 4:30 PM, surveyors in the presence of the Service Technician from the General Maintenance Department, the following were not met: 1. The 1-hour smoke separation wall located in the Birthing Section in the storage room and the IT room on Level 1 the wall above the ceiling tiles at the top had open penetrations that were not fireproffed. This deficient practice could affect the occupants, visitors and staff while trying to exit the building or sheltering in place. Surveyors confirmed this finding with the Service Technician from the General Maintenance Department at the time of the observation.”
-
Gas And Vacuum Piped Systems - Inspection And
The inspectors’ words, 393 words
“Gas and Vacuum Piped Systems - Inspection and CFR(s): NFPA 101 Gas and Vacuum Piped Systems - Inspection and Testing Operations The gas and vacuum systems are inspected and tested as part of a maintenance program and include the required elements. Records of the inspections and testing are maintained as required. 5.1.14.2.3, B.5.2, 5.2.13, 5.3.13, 5.3.13.4 (NFPA 99) This Standard is not met as evidenced by: 50034 Federal Recertification Survey Date: 09/10/2025 Based on observation, interview and record review, the critical access hospital failed to comply with NFPA 99 2011 Edition Chapter 5. The gas and vacuum systems are inspected and tested as part of a maintenance program and include the required elements. Records of the inspections and testing are maintained as required. 5.1.14.2.3, B.5.2, 5.2.13, 5.3.13, 5.3.13.4 5.1.12.2.6.6, 5.1.4.8.8, 5.1.11.2, 5.1.5.16, 5.1.3.6.3.12 (E), 5.1.10.3.1 and 5.1.10.4 This deficient practice could impact patients, staff, family members and the general public in an event of a system failure. Findings: During a documentation review on 09/10/2025 between the hours of 8:00 AM and 2:00 PM, a surveyor with the Plant Operations Manager observed the following: The Medical Gas Report has deficiencies listed as follows: Maintenance Deficiencies: 1. Emergency Room 8: Medical air outlet leaks from back check. 2. Radiology CT Scan: Vacuum inlet leaks 3. Day Surgery Room 3: 2nd Vacuum inlet leaks 4. Endoscopy Procedure Room 2: 2nd Vacuum inlet leaks. 5. Operating Room 3: 3rd Vacuum inlet on wall leaks. 6. Special Care Unit Room 4: 3rd Vacuum inlet Leaks Compliance Deficiencies: 1. Radiology: Zone valves located right of DEXA Room need to be labeled, X-Ray 1-3, Ultrasound, Nuc Medicine, DEXA. 2. Operating Rooms 1-3: There are no dedicated WGAD inlets installed in these Anesthetizing locations. 5.1.10.2.3 3. Medical Air Compressor: Medical air intake is piped inside the air handler for the operating room filtered air. If the ventilation system has fans with motors or drive belts then this shall not be used as a source for the medical air intake. 4. Vacuum Pump: Vacuum main line piping has sections that are soft soldered and not completed using acceptable joining methods. Documentation was provided on work orders that were issued on some of the deficiencies at the time of survey but they have not been completed. These observations were confirmed by the surveyor and Plant Operations Director at the time of documentation review.”
-
Gas Equipment - Cylinder And Container Storag
The inspectors’ words, 479 words
“Gas Equipment - Cylinder and Container Storag CFR(s): NFPA 101 Gas Equipment - Cylinder and Container Storage Greater than or equal to 3,000 cubic feet Storage locations are designed, constructed, and ventilated in accordance with 5.1.3.3.2 and 5.1.3.3.3. >300 but <3,000 cubic feet Storage locations are outdoors in an enclosure or within an enclosed interior space of non- or limited- combustible construction, with door (or gates outdoors) that can be secured. Oxidizing gases are not stored with flammables, and are separated from combustibles by 20 feet (5 feet if sprinklered) or enclosed in a cabinet of noncombustible construction having a minimum 1/2 hr. fire protection rating. Less than or equal to 300 cubic feet In a single smoke compartment, individual cylinders available for immediate use in patient care areas with an aggregate volume of less than or equal to 300 cubic feet are not required to be stored in an enclosure. Cylinders must be handled with precautions as specified in 11.6.2. A precautionary sign readable from 5 feet is on each door or gate of a cylinder storage room, where the sign includes the wording as a minimum “CAUTION: OXIDIZING GAS(ES) STORED WITHIN NO SMOKING.” Storage is planned so cylinders are used in order of which they are received from the supplier. Empty cylinders are segregated from full cylinders. When facility employs cylinders with integral pressure gauge, a threshold pressure considered empty is established. Empty cylinders are marked to avoid confusion. Cylinders stored in the open are protected from weather. 11.3.1, 11.3.2, 11.3.3, 11.3.4, 11.6.5 (NFPA 99) This Standard is not met as evidenced by: 50034 Based on observation, the critical access hospital failed to ensure that Gas Equipment - Cylinder and Container Storage in a single smoke compartment, individual cylinders available for immediate use in patient care areas with an aggregate volume of less than or equal to 300 cubic feet are not required to be stored in an enclosure. Cylinders must be handled with precautions as specified in 11.6.2. A precautionary sign readable from 5 feet is on each door or gate of a cylinder storage room, where the sign includes the wording as a minimum “CAUTION: OXIDIZING GAS(ES) STORED WITHIN NO SMOKING.” This deficient practice could affect staff, patients, family members and general public while trying to exit the building or shelter in place. Findings: On 09/09/2025, between 9:30 AM and 4:30 PM, a surveyor, with the Maintenance present, observed the following: 1. The storage room located in the medical surgical patient area has 2 oxygen tanks stored inside it with no signage present annotating oxygen storage. 2. The Pulmonary Function Testing Storage room has approximately 8 type E tanks stored in a rack system (under 300 cubic feet) and does not have any signage present on the exterior annotating oxygen storage. The surveyor confirmed this finding with the Maintenance at the time of the observation.”
All 7 inspections in the last three years
| Date | Visit | What the record says |
|---|---|---|
| Aug 11, 2026 | Complaint inspection | 1 deficiency cited |
| Mar 10, 2026 | Complaint inspection | No deficiencies cited |
| Sep 11, 2025 | Standard inspection | No deficiencies cited |
| Sep 10, 2025 | Standard inspection | 10 deficiencies cited |
| Feb 4, 2025 | Complaint inspection | No deficiencies cited |
| Oct 8, 2024 | Complaint inspection | No deficiencies cited |
| Feb 6, 2024 | Complaint inspection | No deficiencies cited |
How do patients fare?
- CMS’s overall CMS rates some kinds of place from 1 to 5 stars, more stars meaning better on CMS’s own measures for that kind: for a nursing home, its health inspections, staffing and quality measures. A rating is CMS’s summary of those measures; it doesn’t promise good care. Source: CMS, Care Compare and the Five-Star Quality Rating System. for it is 2 of 5.
- Of the measures behind its CMS rates some kinds of place from 1 to 5 stars, more stars meaning better on CMS’s own measures for that kind: for a nursing home, its health inspections, staffing and quality measures. A rating is CMS’s summary of those measures; it doesn’t promise good care. Source: CMS, Care Compare and the Five-Star Quality Rating System., CMS counts against the national value: mortality, 0 better and 0 worse of 6; safety of care, 0 better and 0 worse of 1; readmission, 0 better and 0 worse of 6.
- Patients rate it 5 of 5 in CMS’s patient survey (203 surveys completed, Oct 1, 2024 to Sep 30, 2025): 80% rated it 9 or 10 out of 10, and 79% would definitely recommend it.
- Infections, compared by CMS with the national benchmark (Oct 1, 2024 to Sep 30, 2025): C. diff infections, no different than national benchmark.
- Deaths within 30 days, as CMS gives them (Jul 1, 2022 to Jun 30, 2025): heart failure 14.3%, pneumonia 16%, COPD 12.1%, stroke 14.2%. CMS gives no comparison with the national rate for them in this release.
- Readmissions within 30 days, as CMS gives them (Jul 1, 2023 to Jun 30, 2025): heart failure 19.9%, pneumonia 15.7%, COPD 18.8%, hip or knee replacement 5.3%. CMS gives no comparison with the national rate for them in this release.
- After outpatient care, compared by CMS: hospital admissions after outpatient chemotherapy, no different than the national rate; emergency visits after outpatient chemotherapy, no different than the national rate.
- Emergency department patients spent a median of 128 minutes there before leaving (Oct 1, 2024 to Sep 30, 2025), and 2% left before being seen.
- 84% of patients with severe sepsis or septic shock got the care CMS measures, SEP-1 (Oct 1, 2024 to Sep 30, 2025).
CMS, Hospital General Information, Patient survey (HCAHPS) - Hospital, Healthcare Associated Infections - Hospital, Timely and Effective Care - Hospital and Medicare Spending Per Beneficiary - Hospital. Released Aug 13, 2026. Updated quarterly.
CMS, Complications and Deaths - Hospital and Unplanned Hospital Visits - Hospital. Released Sep 30, 2026. Updated quarterly.
| Measure | Rating |
|---|---|
| Overall ratingCMS’s overall hospital quality star rating, 1 to 5 | 2 of 5 |
| Patient survey ratingCMS star rating from its survey of the hospital’s patients (HCAHPS), 1 to 5 | 5 of 5 |
Is it certified, and in good standing?
- Medicare-certified critical access hospital since Dec 31, 2005.
- Ownership: voluntary non-profit - private.
- It is not accredited by a private organisation, so the state carries out its routine inspections for Medicare.
- No For hospices, home health agencies, hospitals and dialysis facilities, CMS writes deficiencies at two levels. Standard is the usual one; condition-level is the more serious, when a problem is serious enough that the provider doesn’t meet a whole condition of taking part in Medicare. Source: CMS, State Operations Manual. deficiency on record in the last three years.
- Voluntary non-profit - Private.
CMS, Provider of Services File - Hospital & Non-Hospital Facilities. Released Oct 14, 2026. Updated quarterly.
CMS, Hospital General Information. Released Aug 13, 2026. Updated quarterly.
CMS, QCOR Hospital 2567 statements of deficiencies. Released Oct 20, 2026. Updated monthly.
Has it been penalized?
- CMS doesn’t publish fines or other penalties for hospitals.
- CMS’s HAC Reduction Program file has no result for it: the program covers general acute care hospitals Medicare pays under its inpatient prospective payment system.
- 1 deficiency cited in the last three years came from an inspection that included a complaint investigation.
CMS, Hospital-Acquired Condition (HAC) Reduction Program. Released Aug 13, 2026. Updated yearly.
CMS, Provider of Services File - Hospital & Non-Hospital Facilities. Released Oct 14, 2026. Updated quarterly.
CMS, QCOR Hospital 2567 statements of deficiencies. Released Oct 20, 2026. Updated monthly.
What do patients say about their care?
- CMS doesn’t publish staffing levels for hospitals.
- In CMS’s patient survey, patients rate how well its nurses communicated 5 of 5.
- 100% of its health care workers got a flu shot (Oct 1, 2024 to Mar 31, 2025).
CMS, Patient survey (HCAHPS) - Hospital and Timely and Effective Care - Hospital. Released Aug 13, 2026. Updated quarterly.
Who owns it?
- 21 owners or officers are people: Richard Willett (corporate officer, 0%); Richard Willett (corporate director); Richard Willett (managing employee (on the payroll)); Michael P Curran (corporate director); Sam Hight (corporate director, 0%); William Laney (corporate director); Dana Kempton (corporate director, 0%); Dana Kempton (managing employee (on the payroll)); Jeffrey A Mcgown (corporate director, 0%); Elmer H Doucette (corporate officer, 0%); Elmer H Doucette (corporate director, 0%); Elmer H Doucette (managing employee (on the payroll), 0%); Crystal Neace (managing employee (on the payroll), 0%); Crystal Neace (runs it (operational or managerial control), 0%); Michael H Lambke (corporate director); Vicki Alward (corporate director, 0%); L Joseph Clark (corporate director); Gina S Gomez (corporate director); Christopher Perkins (corporate director); Kim M Gray (managing employee (on the payroll), 0%); Kim M Gray (runs it (operational or managerial control), 0%).
- CMS’s Provider of Services file records 3 changes of ownership.
- No private-equity firm among the owners CMS lists.
- No real-estate investment trust among the owners CMS lists.
CMS, Hospital All Owners and Hospital Enrollments. Released Sep 29, 2026. Updated monthly.
CMS, Provider of Services File - Hospital & Non-Hospital Facilities. Released Oct 14, 2026. Updated quarterly.
How does it compare nearby?
- Of the 2 hospitals CMS lists in Somerset County, 2 have an overall star rating from CMS: 2 rated 2 of 5.
- CMS rates this one 2 of 5.
CMS, Hospital General Information. Released Aug 13, 2026. Updated quarterly.
| Place | Overall star rating |
|---|---|
| Northern Light Sebasticook Valley Hospital | 2 |
What the record doesn’t say
- CMS doesn’t publish fines or other penalties for hospitals, so none are shown. The one payment cut CMS publishes for each hospital, under its Hospital-Acquired Condition Reduction Program, is shown where it applies.
- Only complaints that led to a citation appear; complaints that didn’t aren’t published.
- Most hospitals are accredited by a private organisation (The Joint Commission, DNV and others) whose routine inspections stand in for the state’s; those reports aren’t public, and QCOR holds only the state’s surveys: no inspection on record here doesn’t mean none took place.
- QCOR says its hospital inspection data are complete only through September 17, 2026, while it moves to a new system.
- CMS doesn’t publish staffing levels for hospitals.
- In its September 2026 release CMS gives no comparison with the national rate for death and readmission rates, though it gives the rates.
Sources
-
Centers for Medicare & Medicaid Services, Hospital General Information (xubh-q36u).
Released Aug 13, 2026 and checked Nov 5, 2026. Updated quarterly. Public domain (U.S. Government work).
-
Centers for Medicare & Medicaid Services, Patient survey (HCAHPS) - Hospital.
Released Aug 13, 2026 and checked Nov 5, 2026. Updated quarterly. Public domain (U.S. Government work).
-
Centers for Medicare & Medicaid Services, Healthcare Associated Infections - Hospital (77hc-ibv8).
Released Aug 13, 2026 and checked Nov 5, 2026. Updated quarterly. Public domain (U.S. Government work).
-
Centers for Medicare & Medicaid Services, Complications and Deaths - Hospital (ynj2-r877).
Released Sep 30, 2026 and checked Nov 5, 2026. Updated quarterly. Public domain (U.S. Government work).
-
Centers for Medicare & Medicaid Services, Unplanned Hospital Visits - Hospital (632h-zaca).
Released Sep 30, 2026 and checked Nov 5, 2026. Updated quarterly. Public domain (U.S. Government work).
-
Centers for Medicare & Medicaid Services, Timely and Effective Care - Hospital (yv7e-xc69).
Released Aug 13, 2026 and checked Nov 5, 2026. Updated quarterly. Public domain (U.S. Government work).
-
Centers for Medicare & Medicaid Services, Medicare Spending Per Beneficiary - Hospital (rrqw-56er).
Released Aug 13, 2026 and checked Nov 5, 2026. Updated quarterly. Public domain (U.S. Government work).
-
Centers for Medicare & Medicaid Services, Hospital-Acquired Condition (HAC) Reduction Program (yq43-i98g).
Released Aug 13, 2026 and checked Nov 5, 2026. Updated yearly. Public domain (U.S. Government work).
-
Centers for Medicare & Medicaid Services, Provider of Services File - Hospital & Non-Hospital Facilities (Hospital_and_other.DATA.Q3_2026.csv).
Released Oct 14, 2026 and checked Nov 5, 2026. Updated quarterly. Public domain (U.S. Government work).
-
Centers for Medicare & Medicaid Services, QCOR Hospital 2567 statements of deficiencies (Hospital_2567s_2010_to_2026YTD.xlsx).
Released Oct 20, 2026 and checked Oct 27, 2026. Updated monthly. Public domain (U.S. Government work).
-
Centers for Medicare & Medicaid Services, Hospital All Owners (Hospital_All_Owners_2026.09.29.csv).
Released Sep 29, 2026 and checked Nov 5, 2026. Updated monthly. Public domain (U.S. Government work).
-
Centers for Medicare & Medicaid Services, Hospital Enrollments (Hospital_Enrollments_2026.09.29.csv).
Released Sep 29, 2026 and checked Nov 5, 2026. Updated monthly. Public domain (U.S. Government work).
If you believe something here is wrong, a correction starts with the agency whose record this copies: CMS. CMS’s own record is on Care Compare. If Hearth Record copied something wrongly, it will fix it and log the correction publicly, with its date: how corrections work.
This copy of the record was made on Nov 5, 2026.
From the hospital
The public record above comes first. Anything the hospital adds will appear here, below it, and say who wrote it.
Replies
None. Replies aren’t open yet. When they open, the hospital will be able to answer any finding for free, and the reply will show beside that finding, unedited and dated.
Paid listing
None. Paid listings aren’t open yet. When they open, anything paid for will say “Paid by the hospital”, and paying will never change a finding, a rating or the order of results.