Goshen Hospital
An acute care hospital in Goshen, Indiana 46526
200 High Park Ave, Goshen, Indiana 46526. (574) 364-1000.
- Medicare payments cut under the HAC Reduction Program (fiscal year 2026)
Watch and the shortlist are kept with a free account, on every device. Your watch list. CMS’s own record is on Care Compare.
The short answer
Record last released by CMS on Oct 20, 2026.
- 3of 5 CMS’s overall rating
- 4of 5 patient survey rating
- 4 deficiencies cited in the last three years (needs attention)
- 123 beds
Each figure’s source sits beside it, in its section below.
What these words mean4
- Star ratings
- CMS rates some kinds of place from 1 to 5 stars, more stars meaning better on CMS’s own measures for that kind: for a nursing home, its health inspections, staffing and quality measures. A rating is CMS’s summary of those measures; it doesn’t promise good care. Source: CMS, Care Compare and the Five-Star Quality Rating System.
- Inspection (survey)
- A visit by state inspectors, often unannounced, who check a place against the rules it must meet. For nursing homes and other places Medicare pays, CMS calls these visits surveys: a standard survey of a nursing home comes at least every 15 months, and a complaint survey whenever a complaint calls for one. Source: CMS; 42 CFR 488.308.
- Deficiency, citation, violation
- What inspectors write up when a place didn’t meet a rule: the rule, what they saw, and when. CMS calls it a deficiency; states may say citation or violation. It is the inspectors’ finding, not a court’s, and the place is usually asked for a plan to correct it. Source: CMS, statement of deficiencies (Form CMS-2567); each state’s licensing agency.
- Condition-level deficiency
- For hospices, home health agencies, hospitals and dialysis facilities, CMS writes deficiencies at two levels. Standard is the usual one; condition-level is the more serious, when a problem is serious enough that the provider doesn’t meet a whole condition of taking part in Medicare. Source: CMS, State Operations Manual.
What did inspectors find?
The last inspection on record was on Jan 24, 2025: a complaint inspection.
4 deficiencies cited in the last three years, 2 of them at condition level, the most serious.
2 deficiencies at condition level, the more serious of CMS’s two levels
CMS, QCOR Hospital 2567 statements of deficiencies. Released Oct 20, 2026. Updated monthly.
When those deficiencies happened
4 deficiencies in 2 months of the last 36. Last cited Jan 2025. Most serious: Condition-level. The last 3 years, to Nov 5, 2026.
| Jan | Feb | Mar | Apr | May | Jun | Jul | Aug | Sep | Oct | Nov | Dec | |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 2023 | Dec | |||||||||||
| 2024 | Jan | Feb | Mar | Apr | May | Jun | Jul | Aug | Sep | Oct | Nov | Dec |
| 2025 | Jan | Feb | Mar | Apr | May | Jun | Jul | Aug | Sep | Oct | Nov | Dec |
| 2026 | Jan | Feb | Mar | Apr | May | Jun | Jul | Aug | Sep | Oct | Nov |
Hover or focus a month to read it.
Hearth Record drew this from the dates and levels in the source’s own records.
Each deficiency, as cited
Rule titles as CMS’s inspectors cite them, set in sentence case.
CMS, QCOR Hospital 2567 statements of deficiencies. Released Oct 20, 2026. Updated monthly.
Jan 24, 2025: complaint inspection2 deficiencies
-
Nursing Services
The inspectors’ words, 106 words
“NURSING SERVICES CFR(s): 482.23 The hospital must have an organized nursing service that provides 24-hour nursing services. The nursing services must be furnished or supervised by a registered nurse. This Condition is not met as evidenced by: 47186 Based on document review and interview, nursing services failed to ensure fall prevention safety measures were implemented, failed to document a patient’s fall(s) in the Event Report Log, and failed to notify the attending provider after a patient fall in 1 of 10 medical records reviewed (patient 5). The cumulative effects of these systemic problems resulted in the facility’s inability to provide nursing care in a safe manner.”
-
Rn Supervision Of Nursing Care
The inspectors’ words, 643 words
“RN SUPERVISION OF NURSING CARE CFR(s): 482.23(b)(3) A registered nurse must supervise and evaluate the nursing care for each patient. This Standard is not met as evidenced by: 47186 Based on document review and interview, nursing services failed to ensure fall prevention safety measures were implemented, failed to document a patient’s fall(s) in the Event Report Log, and failed to notify the attending provider after a patient fall in 1 of 10 medical records (MRs) reviewed (patient 5). Findings include: 1. Facility policy titled: ED Fall Prevention Protocol, last reviewed 3/11/2022, indicated under I. Assess a. The Memorial Emergency Department Fall Risk Assessment tool should be used at the following times to help predict which patients are at risk of falling: i. Upon admission to the Emergency Department. ii. After a fall occurs. 2. Facility policy titled: Fall Event Management Protocol, last reviewed 04/2022, indicated under Managing a Fall B. When a fall happens, Colleagues involved, the House Supervisor, and the family/patient discuss the event in a huddle immediately following the event. A risk event report is completed, which includes a post-fall huddle tool. The tool guides the conversation between members of the huddle to identify the type of fall (developmental, physiological, suspected intention or unintentional). Risk factors and defects contributing to the fall are also identified. The tool guides the huddle members to discover additional interventions to prevent further falls for the patient. C. Action to take by role: 2. Registered Nurse. b. Notify the attending or covering physician or nurse practitioner. e. Document the fall event and huddle results in risk event in Infohub or Midas. f. Reassess fall risk and injury risk and update patient’s care plan. D. Communication: Clear and timely communication with the family preserves families’ trust. 1. A physician or nurse practitioner is always to be notified of the fall. They will assess the patient based on collaborative discussion with the RN. Definitions: Fall: A sudden, unintentional descent, with or without injury to the patient, which results in the patient coming to rest on the floor, on or against some other surface (e.g., a counter), on another person, or on an object (e.g., a trash can). When a patient rolls off a low bed onto a mat or is found on a surface where you would not expect to find a patient, this is considered a fall. If a patient who is attempting to stand or sit falls back onto a bed, chair or commode, this is only counted as a fall if the patient is injured. Fall Types: 2. Physiological: A fall attributable to one or more intrinsic, physiologic factors (e.g., hypotension, dysrhythmia, seizure, TIA/stroke, side of effect of certain medications, delirium, intoxication, dementia, gait instability, or visual impairment). 3. Review of patient 5’s MR indicated the following: a. patient presented to facility ED (Emergency Department) on 12/10/24 at approximately 8:00 pm with complaint of headache and seizure, fall at home earlier in the day, chest pain, low back pain and muscle spasms. MR indicated patient fell, while at facility, from wheelchair at approximately 8:16 pm and 8:58 pm, and a fall from patient’s bed at approximately 9:15 pm, on 12/10/24. MR lacked documentation of provider notification after patient’s 2nd and 3rd fall. b. MR lacked documentation of fall prevention safety measures assessed/implemented until after patient’s 3rd fall. 4. Administrative document review lacked documentation of Event Reporting related to patient 5’s three falls during facility visit on 12/10/24. 5. In interview on 1/23/25 at approximately 2:00 pm, A1 (Director of Clinical Quality) confirmed there were no Event Report of P5’s falls during ED visit on 12/10/24, per policy. 6. In telephone interview on 1/24/25 at approximately 12:52 pm to 1:03 pm, N7 (Registered Nurse) confirmed he/she did not create an Event Report for P5’s fall from bed, and thought the charge nurse had reported this event.”
Dec 19, 2023: complaint inspection2 deficiencies
-
Infection Prevention Control Abx Stewardship
The inspectors’ words, 182 words
“INFECTION PREVENTION CONTROL ABX STEWARDSHIP CFR(s): 482.42 The hospital must have active hospital-wide programs for the surveillance, prevention, and control of HAIs and other infectious diseases, and for the optimization of antibiotic use through stewardship. The programs must demonstrate adherence to nationally recognized infection prevention and control guidelines, as well as to best practices for improving antibiotic use where applicable, and for reducing the development and transmission of HAIs and antibiotic resistant organisms. Infection prevention and control problems and antibiotic use issues identified in the programs must be addressed in collaboration with the hospital-wide quality assessment and performance improvement (QAPI) program. This Condition is not met as evidenced by: 32952 Based on document review and interview, the facility failed to ensure staff followed their policy related to flexible scope cleaning and implementation of manufacturers procedure for delay in reprocessing for 13 of 13 medical records reviewed. (Patients #1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12 and 13) See tag 0749 The cumulative effects of the above resulted in the facility inability to provide services in a safe manner.”
-
Infection Control Program
The inspectors’ words, 3,846 words
“INFECTION CONTROL PROGRAM CFR(s): 482.42(a)(1) The hospital infection prevention and control program, as documented in its policies and procedures, employs methods for preventing and controlling the transmission of infections within the hospital and between the hospital and other institutions and settings; This Standard is not met as evidenced by: 32952 Based on document review and interview, the facility failed to ensure staff followed their policy related to flexible scope cleaning and implementation of manufacturers procedure for delay in reprocessing for 13 of 13 medical records reviewed. (Patients #1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12 and 13) Findings include: 1. A review of policy titled “Flexible Scope Cleaning 2020-1” Visiting Policy” last reviewed/revised on 1/1/20 indicated the following: “...POLICY...will ensure that endoscopes are reprocessed in accordance with regulatory and expert guidelines. PURPOSE: Provide guidance for reprocessing of all types of reusable flexible endoscopes and accessories...III. A. Precleaning at the point of use. Precleaning should be performed at the point of use. Manual cleaning is performed at the bedside after each case to remove debris before bioburden can form before transport to cleaning area. Record of the procedure’s end time and start time of manual cleaning will be marked on the patient’s sticker. Recording these times will ascertain the reprocessing personnel how long the endoscope has been awaiting reprocessing to determine whether routine reprocessing according to manufacturer’s recommendations is achievable, and if not, to implement the manufacturer’s procedure for delayed processing. D. Manual Cleaning & Inspection: If the manual cleaning is not performed within the timeframe of the manufacturer’s IFU (Instructions for Use), the scope cleaner will implement the manufacturer’s procedure for delayed processing.” 2. A review of an article provided by N3 (Manager of Endoscopy/Registered Nurse) on 12/19/23 that was written by the Infection Control Manager of Olympus titled “Delays in Endoscope Reprocessing...and the Biofilms Within”, last updated on 9/22/23 indicated the following: “Introduction: In addition to the time commitment required by staff, there are time constraints that need to be adhered to in order to reprocess devices effectively. One such time constraint is the maximum time delay allowed by endoscope manufacturers between precleaning of the endoscope at bedside after the procedure has been completed and the start of leak testing and manual cleaning. Olympus mandates a maximum dwell time between precleaning and manual cleaning of 60 minutes. If the endoscope sits awaiting manual cleaning for over 60 minutes, then a delayed reprocessing or presoaking protocol must be performed in order for the device to be reprocessed effectively. Why does Olympus require a maximum of 60 minutes between steps and not 30 minutes, 90 minutes, or any other amount of time? The answer is multifaceted and includes input from the FDA (Food and Drug Administration), the process of reprocessing instruction validation, and the science behind biofilm formation. Studies show that patient infections have occurred when reprocessing was delayed. It is important to understand that reprocessing endoscopes as soon as possible after procedural use is essential. Endoscope reprocessing begins with precleaning at the bedside. Precleaning should be performed immediately after the end of the procedure. Transport to the reprocessing area and manual cleaning should begin as soon as possible once the endoscope has been precleaned. Failure to adhere to the endoscope manufacturer’s reprocessing protocol and delaying the cleaning of endoscopes may compromise patient safety and lead to an infection control risk. Ideally, endoscope reprocessing should begin with precleaning immediately after removal of the endoscope from the patient cavity and continue with minimal disruptions throughout manual cleaning, high-level disinfection/sterilization and into storage. When reprocessing is delayed beyond 60 minutes, Olympus recommends performing an extended soaking procedure, often referred to as “presoaking” or “delayed reprocessing”. Conclusion: Failing to keep accurate records of the time between precleaning and manual cleaning is not only a lapse in following reprocessing instructions but also a patient safety issue. The drying of organic debris and bioburden, even in the smallest amounts, can result in ineffective cleaning and disinfection of the endoscope and encourage growth of biofilms. Each facility should develop a method of documenting the time when reprocessing steps occur. In addition to documentation, communication needs to occur between staff members within the facility.” 3. Review of patient #1’s medical record indicated the following: (A) The patient was admitted on 11/25/23 (B) The patient had a Bronchoscopy and bronchial washing on 12/3/23 with a start time of 12:45 p.m. (C) The instrument used in the procedure was an Olympus BF-P190 Bronchovideoscope/ICU (Intensive Care Unit) with scope number #2752. (D) The medical record lacked documentation of the procedure stop date and time. The medical record lacked documentation of the dates and times of the bedside cleaning of the endoscope along with when the endoscope was taken to the decontamination area. A review of the endoscopy reprocessing log for Patient #1 indicated that the (AER) Automated Endoscope Reprocessor was started on 12/3/23 at 6:37 p.m. for the endoscope used for Patient #1. The endoscopy reprocessing log lacked documentation of the date and time the endoscope arrived at the decontamination area, whether the endoscope was soaked along with start and end times and the start time of the manual cleaning, therefore unable to determine if the facility followed their policy related to delay in reprocessing scopes and/or the manufacturer’s IFU’s. 4. Review of patient #2’s medical record indicated the following: (A) The patient was admitted on 12/1/23 (B) The patient had a Bronchoscopy and bronchial washing on 12/3/23 with a start time of 11:00 a.m. (C) The instrument used in the procedure was an Olympus BF-1TH190 Bronchovideoscope/OR (Operating Room) with scope number #3387. (D) The medical record lacked documentation of the procedure stop date and time. The medical record lacked documentation of the dates and times of the bedside cleaning of the endoscope along with when the endoscope was taken to the decontamination area. The endoscopy reprocessing log for Patient #2 indicated that the (AER) was started on 12/3/23 at 6:50 p.m. for the endoscope used for Patient #2. The endoscopy reprocessing log lacked documentation of the date and time the endoscope arrived at the decontamination area, whether the endoscope was soaked along with start and end times and the start time of the manual cleaning, therefore unable to determine if the facility followed their policy related to delay in reprocessing scopes and/or the manufacturer’s IFU’s. 5. Review of patient #3’s medical record indicated the following: (A) The patient was admitted on 12/1/23 (B) The patient had an ERCP (Endoscopic Retrograde Cholangiopancreatography) on 12/11/23 with a start time of 9:09 p.m. and a stop time of 9:45 p.m. (C) The instrument used in the procedure was an Olympus TJF-Q190 Duodenovideoscope with scope number #2226548. (D) The medical record lacked documentation of the dates and times of the bedside cleaning of the endoscope along with when the endoscope was taken to the decontamination area. The endoscopy reprocessing log for Patient #3 indicated that the AER was started on 12/12/23 at 4:48 p.m. for the endoscope used for Patient #3. A time lapse of approximately 19 hours from end of procedure to the start of the AER. The endoscopy reprocessing log lacked documentation of the date and time the endoscope arrived at the decontamination area, whether the endoscope was soaked along with start and end times and the start time of the manual cleaning, therefore unable to determine if the facility followed their policy related to delay in reprocessing of endoscopy scopes and/or the manufacturer’s IFU’s. 6. Review of patient #4’s medical record indicated the following: (A) The patient was admitted on 12/1/23. (B) The patient had a Bronchoscopy with Endobronchial ultrasound with biopsy on 12/11/23 with a start time of 12:50 p.m. and a stop time of 3:08 p.m. (C) The following instruments were used in the procedure which included: 1.) An Olympus BF-1TH190 Bronchovideoscope with scope number #2723430, 2.) An Olympus BF-P190 with scope number #2711687 and 3.) An Olympus UC180F with scope number #3930. (D) The medical record lacked documentation of the dates and times of the bedside cleaning of the endoscope along with when the endoscope was taken to the decontamination area. The endoscopy reprocessing log for Patient #4 indicated the following: 1.) Olympus BF-1TH190 scope number #2723430 the (AER) was started on 12/12/23 at 4:50 p.m., which indicated a time lapse of approximately 1.50 hours from end of procedure to start of AER. 2.) Olympus BF-P190 scope number #2711687 the (AER) was started on 12/13/23 at 10:11 a.m., which indicated a time lapse of approximately 44 hours from end of procedure to start of AER. 3.) Olympus UC180F scope number #3930 the (AER) was started on 12/13/23 at 10:12 a.m. A time lapse of approximately 44 hours from end of procedure to the start of the AER. The endoscopy reprocessing log lacked documentation of the date and time the endoscope arrived at the decontamination area, whether the endoscope was soaked along with start and end times and the start time of the manual cleaning, therefore unable to determine if the facility followed their policy related to delay in reprocessing of endoscopy scopes and/or the manufacturer’s IFU’s. 7. Review of patient #5’s medical record indicated the following: (A) The patient was admitted on 12/12/23. (B) The patient had a colonoscopy on 12/12/23 with a start time of 12:35 p.m. and a stop time of 1:10 p.m. (C) The instrument used in the procedure was an Olympus CF-HQ190L Colonovideoscope with scope number #2874058. (D) The medical record lacked documentation of the dates and times of the bedside cleaning of the endoscope along with when the endoscope was taken to the decontamination area. The endoscopy reprocessing log for Patient #5 indicated that the AER was started on 12/12/23 at 5:03 p.m. for the endoscope used for Patient #5. A time lapse of approximately 4 hours from end of procedure to the start of the AER. The endoscopy reprocessing log lacked documentation of the date and time the endoscope arrived at the decontamination area, whether the endoscope was soaked along with start and end times and the start time of the manual cleaning, therefore unable to determine if the facility followed their policy related to delay in reprocessing of endoscopy scopes and/or the manufacturer’s IFU’s. 8. Review of patient #6’s medical record indicated the following: (A) The patient was admitted on 12/12/23. (B) The patient had a EGD (Esophagogastroduodenoscopy) with PEG (Percutaneous endoscopic gastrostomy) tube insertion on 12/12/23 with a start time of 11:17 a.m. and a stop time of 11:22 a.m. (C) The instrument used in the procedure was an Olympus GIF-HQ190 Gastrointestinal videoscope with scope number #2858230. (D) The medical record lacked documentation of the dates and times of the bedside cleaning of the endoscope along with when the endoscope was taken to the decontamination area. The endoscopy reprocessing log for Patient #6 indicated that the AER was started on 12/12/23 at 5:13 p.m. for the endoscope used for Patient #6. A time lapse of approximately 6 hours from end of procedure to the start of the AER. The endoscopy reprocessing log lacked documentation of the date and time the endoscope arrived at the decontamination area, whether the endoscope was soaked along with start and end times and the start time of the manual cleaning, therefore unable to determine if the facility followed their policy related to delay in reprocessing of endoscopy scopes and/or the manufacturer’s IFU’s. 9. Review of patient #7’s medical record indicated the following: (A) The patient was admitted on 12/6/23. (B) The patient had an EGD with banding and EUS (endoscopic ultrasound) on 12/7/23 with a start time of 2:04 p.m. and a stop time of 3:49 p.m. (C) An instrument that was used in the procedure was an Olympus GF-UCT180 Ultrasound Gastrovideoscope with scope number #7511192. (D) The medical record lacked documentation of the dates and times of the bedside cleaning of the endoscope along with when the endoscope was taken to the decontamination area. The endoscopy reprocessing log for Patient #7 indicated that the AER was started on 12/8/23 at 10:02 a.m. for the endoscope used for Patient #7. A time lapse of approximately 6 hours from end of procedure to the start of the AER. The endoscopy reprocessing log lacked documentation of the date and time the endoscope arrived at the decontamination area, whether the endoscope was soaked along with start and end times and the start time of the manual cleaning, therefore unable to determine if the facility followed their policy related to delay in reprocessing of endoscopy scopes and/or the manufacturer’s IFU’s. 10. Review of patient #8’s medical record indicated the following: (A) The patient was admitted on 12/7/23. (B) The patient had an EGD with stent removal on 12/7/23 with a start time of 4:51 p.m. and a stop time of 5:16 p.m. (C) The instrument that was used in the procedure was an Olympus GIF-HQ190 Gastrointestinal videoscope with scope number #2511249. (D) The bedside cleaning of the scope was completed on 12/7/23 at 5:20 p.m. (E) The medical record lacked documentation of the date and time when the endoscope was taken to the decontamination area. The endoscopy reprocessing log for Patient #8 indicated that the AER was started on 12/8/23 at 9:40 a.m. for the endoscope used for Patient #8. A time lapse of approximately 16.50 hours from completion of the bedside cleaning of the scope to the start of the AER. The endoscopy reprocessing log lacked documentation of the date and time the endoscope arrived at the decontamination area, whether the endoscope was soaked along with start and end times and the start time of the manual cleaning, therefore unable to determine if the facility followed their policy related to delay in reprocessing of endoscopy scopes and/or the manufacturer’s IFU’s. 11. Review of patient #9’s medical record indicated the following: (A) The patient was admitted on 10/16/23. (B) The patient had an EGD/EUS on 10/16/23 at 2:44 p.m. and a stop time of 3:20 p.m. (C) The instrument that was used in the procedure was an Olympus GIF-HQ190 Gastrointestinal videoscope with scope number #2858230. (D) The bedside cleaning of the scope was completed on 10/16/23 at 2:58 p.m. (E) The medical record lacked documentation of the date and time when the endoscope was taken to the decontamination area. The endoscopy reprocessing log for Patient #9 indicated that the AER was started on 10/17/23 at 9:38 a.m. for the endoscope used for Patient #9. A time lapse of approximately 18 hours from completion of the bedside cleaning of the scope to the start of the AER. The endoscopy reprocessing log lacked documentation of the date and time the endoscope arrived at the decontamination area, whether the endoscope was soaked along with start and end times and the start time of the manual cleaning, therefore unable to determine if the facility followed their policy related to delay in reprocessing of endoscopy scopes and/or the manufacturer’s IFU’s. 12. Review of patient #10’s medical record indicated the following: (A) The patient was admitted on 10/16/23. (B) The patient had an EGD/EUS/ERCP on 10/16/23 at 4:14 p.m. and a stop time of 5:33 p.m. (C) One of the instruments that was used in the procedure was an Olympus GIF-HQ190 Gastrointestinal videoscope with scope number #2858271. (D) The bedside cleaning of the scope was completed on 10/16/23 at 4:35 p.m. (E) The medical record lacked documentation of the date and time when the endoscope was taken to the decontamination area. The endoscopy reprocessing log for Patient #10 indicated that the AER was started on 10/17/23 at 9:53 a.m. for the endoscope used for Patient #10. A time lapse of approximately 17 hours from completion of the bedside cleaning of the scope to the start of the AER. The endoscopy reprocessing log lacked documentation of the date and time the endoscope arrived at the decontamination area, whether the endoscope was soaked along with start and end times and the start time of the manual cleaning, therefore unable to determine if the facility followed their policy related to delay in reprocessing of endoscopy scopes and/or the manufacturer’s IFU’s. 13. Review of patient #11’s medical record indicated the following: (A) The patient was admitted on 10/16/23. (B) The patient had an EGD/colonoscopy on 10/16/23 at 1:22 p.m. and a stop time of 2:17 p.m. (C) One of the instruments that was used in the procedure was an Olympus GIF-HQ190 Gastrointestinal videoscope with scope number #2611453. (D) The bedside cleaning of the scope was completed on 10/16/23 at 1:42 p.m. (E) The medical record lacked documentation of the date and time when the endoscope was taken to the decontamination area. The endoscopy reprocessing log for Patient #11 indicated that the AER was started on 10/17/23 at 10:17 a.m. for the endoscope used for Patient #11. A time lapse of approximately 20 hours from completion of the bedside cleaning of the scope to the start of the AER. The endoscopy reprocessing log lacked documentation of the date and time the endoscope arrived at the decontamination area, whether the endoscope was soaked along with start and end times and the start time of the manual cleaning, therefore unable to determine if the facility followed their policy related to delay in reprocessing of endoscopy scopes and/or the manufacturer’s IFU’s. 14. Review of patient #12’s medical record indicated the following: (A) The patient was admitted on 11/2/23. (B) The patient had an EGD/colonoscopy/ERCP on 11/2/23 at 3:09 p.m. and a stop time of 4:42 p.m. (C) One of the instruments that was used in the procedure was an Olympus GIF-HQ190 Gastrointestinal videoscope with scope number #2611453. (D) The medical record lacked documentation of the dates and times of the bedside cleaning of the endoscope along with when the endoscope was taken to the decontamination area. The endoscopy reprocessing log for Patient #12 indicated that foam was applied to the scope on 11/2/23 at 4:15 p.m. and the AER was started on 11/3/23 at 10:20 a.m. for the endoscope used for Patient #12. A time lapse of approximately 18 hours from application of foam to the scope to the start of the AER. The endoscopy reprocessing log lacked documentation of the date and time the endoscope arrived at the decontamination area, how long the foam stayed on the scope, whether the endoscope was soaked along with start and end times and the start time of the manual cleaning, therefore unable to determine if the facility followed their policy related to delay in reprocessing of endoscopy scopes and/or the manufacturer’s IFU’s. 15. Review of patient #13’s medical record indicated the following: (A) The patient was admitted on 10/30/23. (B) The patient had an EGD/EUS/colonoscopy on 10/30/23 at 6:17 p.m. and a stop time of 7:21 p.m. (C) One of the instruments that was used in the procedure was an Olympus GF-UCT180 Ultrasound Gastrovideoscope with scope number #7511192. (D) The medical record lacked documentation of the date and time when the endoscope was taken to the decontamination area. The endoscopy reprocessing log for Patient #13 indicated that foam was applied to the scope but lacked documentation of the date and time the foam was applied. The log also indicated that the AER was started on 11/1/23 at 9:03 a.m. for the endoscope used for Patient #13. A time lapse of approximately 39 hours from end of procedure to the start of the AER. The endoscopy reprocessing log lacked documentation of the date and time the endoscope arrived to the decontamination area, how long the Intercept foam stayed on the scope, whether the endoscope was soaked along with start and end times and the start time of the manual cleaning, therefore unable to determine if the facility followed their policy related to delay in reprocessing of endoscopy scopes and/or the manufacturer’s IFU’s. 16. During an interview with N1 (Endoscopy Reprocessing Technician) on 12/18/23 at approximately 11:37 a.m., N1 verified that the AERs were used after the manual cleaning of the endoscopes was completed. N1 verified that the endoscopes can only wait to be reprocessed up to 60 minutes per the manufacturer’s guidelines. 17. During an interview with N3 on 12/18/23 at 11:45 a.m., he/she verified that the facility uses Olympus endoscopes and that if there was a delay in reprocessing endoscopes, then they would follow the manufacturer’s guidelines based on the endoscope type. 18. During an interview with N3 on 12/19/23 at 11:30 a.m., N3 verified that there was no policy and procedure for the use of Intercept foam. 19. During an interview with N3 on 12/19/23 at 1:15 p.m., N3 verified that there was no log/record of dates/times when endoscopes arrived from bedside to the decontamination area and/or the manual clean date/time of endoscopes. N3 also verified that there was not always a date/time of bedside point of use cleaning of the endoscopes documented. N3 verified that there was no log/record of “Intercept” foam application/removal date/time and/or soak times of the endoscopes if there was a delay in reprocessing the endoscopes. 20. During an interview with N3 on 12/19/23 at approximately 2:30 p.m., N3 verified that the “Intercept Foam” usage on endoscopes trial started on 8/22/23 through 11/6/23. N3 verified that the trial of “Intercept” foam on endoscopes was stopped due to the facility running out of the foam. N3 verified that they would use the “Intercept” foam on those endoscopes that would have been over an hour before they would be reprocessed. After the use of the foam and when the endoscope was ready to be reprocessed the endoscope would be soaked based on the manufacturer’s guidelines. 21. During an interview with N3 on 12/19/23 at 2:55 p.m., N3 verified the maximum soak times were based on the manufacturer’s IFU’s for the different types of endoscopes that were used. N3 verified the manufacturer’s IFU’s for the maximum soak time for the following endoscopes: (a.) Olympus BF-1TH190 has a one hour maximum soak time and was used in the procedures for Patient’s #1, 2 and 4. (b.) Olympus BF-P190 has a one hour maximum soak time and was used in the procedure for Patient #4. (c.) Olympus TJF-Q190V has a ten hour maximum soak time and was used in the procedure for Patient #3. (d.) Olympus BF-UC180F has a one hour maximum soak time and was in the procedure for Patient #4. (e.) Olympus CF-HQ190L/l has a ten hour maximum soak time and was used in the procedure for Patient #5. (f.) Olympus GIF-HQ190 has a ten hour maximum soak time and was used in the procedures for Patient #6, 7, 8, 9, 10, 11 and 12. (g.) Olympus GF-UE160-AL5 has a ten hour maximum soak time and was used in the procedure for Patient #7. (h.) Olympus GF-UCT180 has a ten hour maximum soak time and was used in the procedure for Patient #7 and # 13. 22. During an interview with A1 and N3 on 12/19/23 at 3:25 p.m., they verified the medical record and endoscopy reprocessing log information for Patients #1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12 and 13.”
All 2 inspections in the last three years
| Date | Visit | What the record says |
|---|---|---|
| Jan 24, 2025 | Complaint inspection | 2 deficiencies cited |
| Dec 19, 2023 | Complaint inspection | 2 deficiencies cited |
How do patients fare?
- CMS’s overall CMS rates some kinds of place from 1 to 5 stars, more stars meaning better on CMS’s own measures for that kind: for a nursing home, its health inspections, staffing and quality measures. A rating is CMS’s summary of those measures; it doesn’t promise good care. Source: CMS, Care Compare and the Five-Star Quality Rating System. for it is 3 of 5.
- Of the measures behind its CMS rates some kinds of place from 1 to 5 stars, more stars meaning better on CMS’s own measures for that kind: for a nursing home, its health inspections, staffing and quality measures. A rating is CMS’s summary of those measures; it doesn’t promise good care. Source: CMS, Care Compare and the Five-Star Quality Rating System., CMS counts against the national value: mortality, 0 better and 2 worse of 6; safety of care, 0 better and 0 worse of 5; readmission, 1 better and 1 worse of 9.
- Patients rate it 4 of 5 in CMS’s patient survey (769 surveys completed, Oct 1, 2024 to Sep 30, 2025): 75% rated it 9 or 10 out of 10, and 75% would definitely recommend it.
- Infections, compared by CMS with the national benchmark (Oct 1, 2024 to Sep 30, 2025): central line bloodstream infections (CLABSI), no different than national benchmark; catheter urinary tract infections (CAUTI), no different than national benchmark; surgical site infections after colon surgery, no different than national benchmark; MRSA bloodstream infections, no different than national benchmark; C. diff infections, better than the national benchmark.
- CMS’s patient safety composite for serious complications, PSI 90, Jul 1, 2022 to Jun 30, 2024: no different than the national value.
- Deaths within 30 days, as CMS gives them (Jul 1, 2022 to Jun 30, 2025): heart attack 13%, heart failure 14.3%, pneumonia 19.4%, COPD 8.8%, stroke 21%. CMS gives no comparison with the national rate for them in this release.
- Readmissions within 30 days, as CMS gives them (Jul 1, 2023 to Jun 30, 2025): heart attack 14.7%, heart failure 20.9%, pneumonia 17.6%, COPD 20.7%. CMS gives no comparison with the national rate for them in this release.
- After outpatient care, compared by CMS: unplanned hospital visits after a colonoscopy, no different than the national rate; hospital admissions after outpatient chemotherapy, no different than the national rate; emergency visits after outpatient chemotherapy, no different than the national rate; unplanned hospital visits after outpatient surgery, no different than expected.
- Emergency department patients spent a median of 158 minutes there before leaving (Oct 1, 2024 to Sep 30, 2025), and 2% left before being seen.
- 63% of patients with severe sepsis or septic shock got the care CMS measures, SEP-1 (Oct 1, 2024 to Sep 30, 2025).
- Medicare’s spending per patient here is 1 times the national median (Jan 1, 2024 to Dec 31, 2024).
CMS, Hospital General Information, Patient survey (HCAHPS) - Hospital, Healthcare Associated Infections - Hospital, Timely and Effective Care - Hospital and Medicare Spending Per Beneficiary - Hospital. Released Aug 13, 2026. Updated quarterly.
CMS, Complications and Deaths - Hospital and Unplanned Hospital Visits - Hospital. Released Sep 30, 2026. Updated quarterly.
| Measure | Rating |
|---|---|
| Overall ratingCMS’s overall hospital quality star rating, 1 to 5 | 3 of 5 |
| Patient survey ratingCMS star rating from its survey of the hospital’s patients (HCAHPS), 1 to 5 | 4 of 5 |
Is it certified, and in good standing?
- Medicare-certified acute care hospital since Jul 1, 1966.
- Ownership: voluntary non-profit - private.
- It is accredited by The Joint Commission, whose surveys stand in for the state’s routine inspections.
- Cited at For hospices, home health agencies, hospitals and dialysis facilities, CMS writes deficiencies at two levels. Standard is the usual one; condition-level is the more serious, when a problem is serious enough that the provider doesn’t meet a whole condition of taking part in Medicare. Source: CMS, State Operations Manual. in the last three years: it didn’t meet a whole condition of Medicare’s rules for hospitals.
- Voluntary non-profit - Private.
CMS, Provider of Services File - Hospital & Non-Hospital Facilities. Released Oct 14, 2026. Updated quarterly.
CMS, Hospital General Information. Released Aug 13, 2026. Updated quarterly.
CMS, QCOR Hospital 2567 statements of deficiencies. Released Oct 20, 2026. Updated monthly.
Has it been penalized?
- CMS doesn’t publish fines or other penalties for hospitals.
- CMS cut its Medicare payments by 1% for fiscal year 2026 under the Hospital-Acquired Condition Reduction Program, which does so for the quarter of hospitals that fare worst on conditions patients get in hospital.
- 4 deficiencies cited in the last three years came from inspections that included a complaint investigation.
CMS, Hospital-Acquired Condition (HAC) Reduction Program. Released Aug 13, 2026. Updated yearly.
CMS, Provider of Services File - Hospital & Non-Hospital Facilities. Released Oct 14, 2026. Updated quarterly.
CMS, QCOR Hospital 2567 statements of deficiencies. Released Oct 20, 2026. Updated monthly.
| Date | What | Detail |
|---|---|---|
| Medicare payment reduction (HAC Reduction Program) | Fiscal year 2026: 1% of Medicare payments |
What do patients say about their care?
- CMS doesn’t publish staffing levels for hospitals.
- In CMS’s patient survey, patients rate how well its nurses communicated 4 of 5.
- 90% of its health care workers got a flu shot (Oct 1, 2024 to Mar 31, 2025).
CMS, Patient survey (HCAHPS) - Hospital and Timely and Effective Care - Hospital. Released Aug 13, 2026. Updated quarterly.
Who owns it?
- 6 owners or officers are people: Lisa Wine (corporate officer, 0%); Lisa Wine (managing employee (on the payroll)); Randal Christophel (corporate officer); Randal Christophel (corporate director); Trisa Schrock (managing employee (on the payroll)); Christine Wert (managing employee (on the payroll)).
- CMS’s Provider of Services file records 1 change of ownership.
- No private-equity firm among the owners CMS lists.
- No real-estate investment trust among the owners CMS lists.
CMS, Hospital All Owners and Hospital Enrollments. Released Sep 29, 2026. Updated monthly.
CMS, Provider of Services File - Hospital & Non-Hospital Facilities. Released Oct 14, 2026. Updated quarterly.
How does it compare nearby?
- Of the 3 hospitals CMS lists in Elkhart County, 2 have an overall star rating from CMS: 1 rated 4 of 5, 1 rated 3 of 5.
- CMS rates this one 3 of 5.
CMS, Hospital General Information. Released Aug 13, 2026. Updated quarterly.
| Place | Overall star rating |
|---|---|
| Elkhart General Hospital | 4 |
| Oaklawn Psychiatric Center Inc. | Not given |
What the record doesn’t say
- CMS doesn’t publish fines or other penalties for hospitals, so none are shown. The one payment cut CMS publishes for each hospital, under its Hospital-Acquired Condition Reduction Program, is shown where it applies.
- Only complaints that led to a citation appear; complaints that didn’t aren’t published.
- Most hospitals are accredited by a private organisation (The Joint Commission, DNV and others) whose routine inspections stand in for the state’s; those reports aren’t public, and QCOR holds only the state’s surveys: no inspection on record here doesn’t mean none took place.
- QCOR says its hospital inspection data are complete only through September 17, 2026, while it moves to a new system.
- CMS doesn’t publish staffing levels for hospitals.
- In its September 2026 release CMS gives no comparison with the national rate for death and readmission rates, though it gives the rates.
Sources
-
Centers for Medicare & Medicaid Services, Hospital General Information (xubh-q36u).
Released Aug 13, 2026 and checked Nov 5, 2026. Updated quarterly. Public domain (U.S. Government work).
-
Centers for Medicare & Medicaid Services, Patient survey (HCAHPS) - Hospital.
Released Aug 13, 2026 and checked Nov 5, 2026. Updated quarterly. Public domain (U.S. Government work).
-
Centers for Medicare & Medicaid Services, Healthcare Associated Infections - Hospital (77hc-ibv8).
Released Aug 13, 2026 and checked Nov 5, 2026. Updated quarterly. Public domain (U.S. Government work).
-
Centers for Medicare & Medicaid Services, Complications and Deaths - Hospital (ynj2-r877).
Released Sep 30, 2026 and checked Nov 5, 2026. Updated quarterly. Public domain (U.S. Government work).
-
Centers for Medicare & Medicaid Services, Unplanned Hospital Visits - Hospital (632h-zaca).
Released Sep 30, 2026 and checked Nov 5, 2026. Updated quarterly. Public domain (U.S. Government work).
-
Centers for Medicare & Medicaid Services, Timely and Effective Care - Hospital (yv7e-xc69).
Released Aug 13, 2026 and checked Nov 5, 2026. Updated quarterly. Public domain (U.S. Government work).
-
Centers for Medicare & Medicaid Services, Medicare Spending Per Beneficiary - Hospital (rrqw-56er).
Released Aug 13, 2026 and checked Nov 5, 2026. Updated quarterly. Public domain (U.S. Government work).
-
Centers for Medicare & Medicaid Services, Hospital-Acquired Condition (HAC) Reduction Program (yq43-i98g).
Released Aug 13, 2026 and checked Nov 5, 2026. Updated yearly. Public domain (U.S. Government work).
-
Centers for Medicare & Medicaid Services, Provider of Services File - Hospital & Non-Hospital Facilities (Hospital_and_other.DATA.Q3_2026.csv).
Released Oct 14, 2026 and checked Nov 5, 2026. Updated quarterly. Public domain (U.S. Government work).
-
Centers for Medicare & Medicaid Services, QCOR Hospital 2567 statements of deficiencies (Hospital_2567s_2010_to_2026YTD.xlsx).
Released Oct 20, 2026 and checked Oct 27, 2026. Updated monthly. Public domain (U.S. Government work).
-
Centers for Medicare & Medicaid Services, Hospital All Owners (Hospital_All_Owners_2026.09.29.csv).
Released Sep 29, 2026 and checked Nov 5, 2026. Updated monthly. Public domain (U.S. Government work).
-
Centers for Medicare & Medicaid Services, Hospital Enrollments (Hospital_Enrollments_2026.09.29.csv).
Released Sep 29, 2026 and checked Nov 5, 2026. Updated monthly. Public domain (U.S. Government work).
If you believe something here is wrong, a correction starts with the agency whose record this copies: CMS. CMS’s own record is on Care Compare. If Hearth Record copied something wrongly, it will fix it and log the correction publicly, with its date: how corrections work.
This copy of the record was made on Nov 5, 2026.
From the hospital
The public record above comes first. Anything the hospital adds will appear here, below it, and say who wrote it.
Replies
None. Replies aren’t open yet. When they open, the hospital will be able to answer any finding for free, and the reply will show beside that finding, unedited and dated.
Paid listing
None. Paid listings aren’t open yet. When they open, anything paid for will say “Paid by the hospital”, and paying will never change a finding, a rating or the order of results.