Hearth Record

Spanish Peaks Regional Health Center

A critical access hospital in Walsenburg, Colorado 81089

23500 Us Highway 160, Walsenburg, Colorado 81089. (719) 738-5100.

CMS’s own record, on Care Compare

Watch and the shortlist are kept with a free account, on every device. Your watch list. CMS’s own record is on Care Compare.

The short answer

Record last released by CMS on Oct 20, 2026.

The last 24 months 6 deficiencies in 2 months of the last 36. Last cited Sep 2025. Most serious: Condition-level. Every month

Each figure’s source sits beside it, in its section below.

What these words mean3
Inspection (survey)
A visit by state inspectors, often unannounced, who check a place against the rules it must meet. For nursing homes and other places Medicare pays, CMS calls these visits surveys: a standard survey of a nursing home comes at least every 15 months, and a complaint survey whenever a complaint calls for one. Source: CMS; 42 CFR 488.308.
Deficiency, citation, violation
What inspectors write up when a place didn’t meet a rule: the rule, what they saw, and when. CMS calls it a deficiency; states may say citation or violation. It is the inspectors’ finding, not a court’s, and the place is usually asked for a plan to correct it. Source: CMS, statement of deficiencies (Form CMS-2567); each state’s licensing agency.
Condition-level deficiency
For hospices, home health agencies, hospitals and dialysis facilities, CMS writes deficiencies at two levels. Standard is the usual one; condition-level is the more serious, when a problem is serious enough that the provider doesn’t meet a whole condition of taking part in Medicare. Source: CMS, State Operations Manual.

What did inspectors find?

The last inspection on record was on Sep 4, 2025: a standard inspection.

6 deficiencies cited in the last three years, 1 of them at condition level, the most serious.

1 deficiency at condition level, the more serious of CMS’s two levels

Source:

CMS, QCOR Hospital 2567 statements of deficiencies. Released Oct 20, 2026. Updated monthly.

When those deficiencies happened

6 deficiencies in 2 months of the last 36. Last cited Sep 2025. Most serious: Condition-level. The last 3 years, to Nov 5, 2026.

6 deficiencies by month over the last 3 years. Each cell is one month.
JanFebMarAprMayJunJulAugSepOctNovDec
2023 Dec
2024 JanFebMarAprMayJunJulAugSepOctNovDec
2025 JanFebMarAprMayJunJulAugSepOctNovDec
2026 JanFebMarAprMayJunJulAugSepOctNov

Hover or focus a month to read it.

No visit on record Visited, nothing cited A stronger orange is more serious, on its source’s own levels, read onto four bands: from the least serious it publishes to the most
Source:

Hearth Record drew this from the dates and levels in the source’s own records.

Each deficiency, as cited

Rule titles as CMS’s inspectors cite them, set in sentence case.

Source:

CMS, QCOR Hospital 2567 statements of deficiencies. Released Oct 20, 2026. Updated monthly.

Sep 4, 2025: standard inspection3 deficiencies
  • Initial Comments - Not A Deficiency Citation

    The inspectors’ words, 134 words

    “The Colorado Department of Fire Prevention and Control conducted this survey was conducted in accordance with the Federal Register at Section 42 CFR 482.41(a). The Initial comments, (ID Prefix Tag #K000) are informational only and a representation of the facility’s general characteristics. The facility is a two (2) story, Type II (111) structure, with no basement, which includes a complete National Fire Protection Association (NFPA) 13 automatic fire suppression system. This survey, conducted on 09/04/2025, inspected the facility for compliance with Chapter 19, Existing Health Care Occupancies,” of the 2012 edition of NFPA 101-Life Safety Code, and other publications as referenced. The facility will meet these requirements when the following deficiencies are corrected. The survey concluded with an exit conference, discussion of the deficiencies in person with the Hospital Administrator and the Maintenance Director.”

    Rule K0000. Standard-level.

  • Fire Alarm System - Testing And Maintenance

    The inspectors’ words, 191 words

    “Fire Alarm System - Testing and Maintenance CFR(s): NFPA 101 Fire Alarm System - Testing and Maintenance A fire alarm system is tested and maintained in accordance with an approved program complying with the requirements of NFPA 70, National Electric Code, and NFPA 72, National Fire Alarm and Signaling Code. Records of system acceptance, maintenance and testing are readily available. 9.6.1.3, 9.6.1.5, NFPA 70, NFPA 72 This Standard is not met as evidenced by: 43825 Through observation during documentation review, it was determined that the facility failed to meet the protection requirements in accordance with NFPA 101 and NFPA 72. This was evidenced by: Fire alarm report says two duct detectors not tested. Life Safety Code section 19.3.4.1 to comply with section 9.6. Section 9.6.1.3, fire alarm system testing and maintenance to comply with NFPA 72. NFPA 72 section 14.4.5 requires, in part, testing shall be performed in accordance with the schedules in Table 14.4.5. This deficiency has the potential to affect occupants, who might include residents, staff, and visitors within 1 of 5 smoke compartments. Deficient items were discussed with the maintenance staff and facility administrator during the exit conference.”

    Rule K0345. Standard-level.

  • Sprinkler System - Maintenance And Testing

    The inspectors’ words, 248 words

    “Sprinkler System - Maintenance and Testing CFR(s): NFPA 101 Sprinkler System - Maintenance and Testing Automatic sprinkler and standpipe systems are inspected, tested, and maintained in accordance with NFPA 25, Standard for the Inspection, Testing, and Maintaining of Water-based Fire Protection Systems. Records of system design, maintenance, inspection and testing are maintained in a secure location and readily available. a) Date sprinkler system last checked _____________________ b) Who provided system test ____________________________ c) Water system supply source __________________________ Provide in REMARKS information on coverage for any non-required or partial automatic sprinkler system. 9.7.5, 9.7.7, 9.7.8, and NFPA 25 This Standard is not met as evidenced by: 43825 Through observation during documentation review, it was determined that the facility failed to meet the protection requirements in accordance with NFPA 101 and NFPA 25. This was evidenced by: Freezer-Escutcheon more than an 1/8 of an inch gap, CT Control Room Escutcheon more than an 1/8 of an inch gap. , EMS Storage Escutcheon more than an 1/8 of an inch gap. Hallway by Room 215 Sprinkler head needs adjusted as it the deflector plate is higher than the escutcheon. 6.2.7.1 Plates, escutcheons, or other devices used to cover the annular space around a sprinkler shall be metallic or shall be listed for use around a sprinkler. This deficiency has the potential to affect occupants, who might include residents, staff, and visitors within all smoke compartments. Deficient items were discussed with the facility administrator and maintenance director during the exit conference.”

    Rule K0353. Standard-level.

Aug 7, 2025: standard inspection3 deficiencies
  • Infection Prevent & Control & Abt Stewar Prog

    The inspectors’ words, 218 words

    “INFECTION PREVENT & CONTROL & ABT STEWAR PROG CFR(s): The CAH must have active facility-wide programs, for the surveillance, prevention, and control of HAIs and other infectious diseases and for the optimization of antibiotic use through stewardship. The programs must demonstrate adherence to nationally recognized infection prevention and control guidelines, as well as to best practices for improving antibiotic use where applicable, and for reducing the development and transmission of HAIs and antibiotic-resistant organisms. Infection prevention and control problems and antibiotic use issues identified in the programs must be addressed in coordination with the facility-wide quality assessment and performance improvement (QAPI) program. This Condition is not met as evidenced by: 44751 Based on the manner and degree of the standard level deficiency referenced to the Condition, it was determined the Condition of Participation §485.640 Infection Prevention and Control and Antibiotic Stewardship Program, was out of compliance. C-1206: The infection prevention and control program, as documented in its policies and procedures, employs methods for preventing and controlling the transmission of infections within the CAH and between the CAH and other healthcare settings. Based on observations, interviews, and document reviews, the facility failed to ensure methods to prevent and control the transmission of infections adhered to nationally accepted standards and guidelines in two of two observations of instrument reprocessing. 52761”

    Rule C1200. Condition-level.

  • Patient Care Policies

    The inspectors’ words, 408 words

    “PATIENT CARE POLICIES CFR(s): [The policies include the following:] (iv) Rules for the storage, handling, dispensation, and administration of drugs and biologicals. These rules must provide that there is a drug storage area that is administered in accordance with accepted professional principles, that current and accurate records are kept of the receipt and disposition of all scheduled drugs, and that outdated, mislabeled, or otherwise unusable drugs are not available for patient use. This Standard is not met as evidenced by: 52761 Based on observations, interviews, and document review, the facility failed to ensure medications in the post-anesthesia care unit (PACU) were securely stored to prevent unauthorized access. Findings include: Facility policy: The Medication Storage Areas policy read, drugs shall be stored in the appropriate drug storage and shall be secured with a security lock, accessible to designated staff only. 1. The facility failed to ensure medications in the expired meds bin were securely stored to prevent unauthorized access. A. Observation i. On 8/4/25 at 11:55 a.m., observations in the PACU revealed an open plastic bin labeled “expired meds” was sitting on top of a refrigerator next to a curtained patient care area. The bin contained two medications, Nitroglycerin (a medication used to treat chest pain by relaxing blood vessels and lowering blood pressure) and Pantoprazole (a medication used to treat conditions in which there is too much acid in the stomach). The medications were accessible to anyone who entered the PACU. This observation was in contrast to the Medication Storage Areas policy which read, drugs should have been stored in the appropriate drug storage and should have been secured with a security lock, accessible to designated staff only. B. Interview i. An interview was conducted on 8/4/25 at 12:05 p.m. with the surgical director (Director) #2. Director #2 stated medications in the PACU should have been secured to prevent unauthorized access. Director #2 stated the Nitroglycerin and Pantoprazole were placed in the plastic bin four days ago. Director #2 stated it was important for medications to be kept behind a locked door, especially in an area accessible to patients and visitors. Director #2 stated there was a safety risk if someone accessed medications that were not secured. Director #2 stated each type of medication had different risks, side effects, and a potential for an allergic reaction. Additionally, Director #2 stated there was a risk of dangerously low blood pressure if someone took a medication that lowered blood pressure.”

    Rule C1016. Standard-level.

  • Infection Prevent & Control Policies

    The inspectors’ words, 1,563 words

    “INFECTION PREVENT & CONTROL POLICIES CFR(s): The infection prevention and control program, as documented in its policies and procedures, employs methods for preventing and controlling the transmission of infections within the CAH and between the CAH and other healthcare settings; This Standard is not met as evidenced by: 44751 Based on observations, interviews, and document reviews, the facility failed to ensure methods to prevent and control the transmission of infections adhered to nationally accepted standards and guidelines in two of two observations of instrument reprocessing. Findings include: Facility policy: The Sterile Processing Department (SPD) Infection Control policy read, trained personnel will be able to demonstrate or verbally explain procedures used for cleaning prior to sterilization according to site-specific policy and or manufacturer/product label directions. References: The Integra Miltex manufacturer’s instructions for use (IFU) read, proper cleaning is essential, an instrument may not be successfully sterilized if it is not completely clean. To ensure effective cleaning, dissimilar metals should be separated, and instruments should be inspected for functionality. Accepted cleaning methods include ultrasonic cleaning (most effective), manual cleaning, and the use of automatic washers. The autoclaving section read, sterilize instruments individually or in sets. Additionally, unlock all hinged instruments and sterilize in an open position. Use a wide enough pouch (peel pack) for instruments with ratchet locks and hinges so the instrument can be sterilized in an open (unlocked) position. Instruments that are locked and closed during autoclaving can develop cracked hinges (box locks) or other problems because of heat expansion. Unlock all instruments and sterilize in an open position. The Rapicide OPA/28 manufacturer’s IFU read, Rapicide is a high-level disinfectant solution for reprocessing of heat sensitive semi-critical medical devices for which sterilization is not suitable. Devices to be reprocessed must first be thoroughly cleaned according to the device manufacturer’s recommendations for decontamination. The Cleaning/Decontamination section read, Rapicide OPA/28 should not be used to high-level disinfect when sterilization is available and practical. The Association of periOperative Registered Nurses (AORN), 2025, Guidelines for Perioperative Practice, Guideline for Instrument Cleaning read, clean and decontaminate surgical instruments according to the manufacturer’s validated, written IFU. Provide the manufacturer’s IFU to personnel responsible for processing instruments and reusable medical devices. IFUs identify the processes necessary to achieve effective decontamination and sterility. Establish a process for regular review of the instrument manufacturers’ IFU to verify facility reprocessing practices comply with the most current manufacturer’s IFU. The instrument manufacturers have determined the steps and processes necessary to clean a device effectively. Unless contraindicated in the manufacturer’s IFU, submerge the device in a cleaning solution that is compatible with the device. The American National Standards Institute/The Association for the Advancement of Medical Instrumentation (ANSI/AAMI) ST79, 2022, read, instrument packaging is intended to maintain the sterility of the instrument and protect the instrument until use. A barrier system (peel pouches) provides a sterile barrier to protect from microorganisms during handling, distribution, transport, and storage. Any instrument in damaged packaging should not be used. 1. The facility failed to ensure surgical instruments were cleaned and sterilized as required by the manufacturer’s IFU, national guidelines, and facility policy. A. Observations i. On 8/4/25 at 11:50 a.m., observations were conducted in the medical clinic. Observations revealed surgical instruments were cleaned with Rapicide. This contrasted with the Rapicide manufacturers IFU which stated, Rapicide was a high-level disinfectant and should not be used to sterilize reusable surgical instruments. The observation also contrasted with the Integra Miltex surgical instrument manufacturer’s IFU which stated, high-level chemical disinfection solution was not an approved cleaning method for the surgical instruments. Medical assistant (MA) #1 was observed transporting surgical instruments used for podiatry procedures to the instrument reprocessing area in a hard blue plastic container. The container held four nail nippers (used to cut thick or tough toenails), three scalpel handles with surgical blades attached, and two nail curettes (used to scrape under and around toenails). MA #1 removed one nail nipper, brushed it under running water, soaked it in Rapicide for 15 minutes, and then rinsed it under running water for one minute. MA #1 placed the nail nipper on a paper towel on the countertop and dried it with a separate paper towel. The instrument was then placed back into the hard blue plastic container, which had not been cleaned. Additionally, the blue container also held other contaminated surgical instruments. At the time of observation, the instrument was not sterile because it had not been autoclaved (sterilized) in an unlocked, open position according to the manufacturer’s IFU, and had also not been enclosed in intact sterile packaging. This observation contrasted with the Integra Miltex manufacturer’s IFU and ANSI/AAMI ST79 guidelines. The Integra Miltex manufacturer’s IFU stated, sterilize individual instruments in an unlocked, open position in a disposable paper or plastic pouch. Additionally, according to ANSI/AAMI ST79 guidelines, sterile packaging must be used to protect surgical instruments from contamination during storage, transportation and handling. Missing or compromised packaging renders the surgical instrument non-sterile. ii. On 8/4/25 at 12:17 p.m., observations were conducted of the peel-packed surgical instruments stored in the clinic. Observations revealed several hinged instruments had been sterilized in the closed or locked position. The instruments observed included eight hemostats (used to clamp blood vessels or hold tissue), four Lahey forceps (with small interlocking teeth for grasping tissue), three Babcock forceps (used to hold soft tissue), and three dissecting scissors (used for cutting tissue). This observation contrasted with the Integra Miltex surgical instrument manufacturer’s IFU which stated, instruments were to be sterilized in the unlocked and open position. Further observations of peel-packed instruments in the clinic revealed eight pairs of single-use disposable Littauer scissors (small surgical scissors) and straight tip forceps (surgical instrument used to grasp and hold), which had been reprocessed and sterilized. During the observation, instrument manufacturer’s IFUs were not observed to be present or readily available and accessible to clinic staff. Upon request, the facility was unable to provide the manufacturer’s IFU for the Littauer scissors and straight tip forceps, or any evidence both instruments could be reprocessed and reused. This was in contrast to AORN Guideline for Instrument Cleaning, which stated, the manufacturers’ IFUs should be readily accessible to staff who clean surgical instruments and reviewed regularly to ensure proper cleaning of the instruments. iii. On 8/6/25 at 9:55 a.m., an observation was conducted in the sterile processing department (SPD). During the observation, surgical technician (Tech) #4 reprocessed surgical instruments from a dilation and curettage set (D&C set). After the observation, the recipe list (a list of every instrument in the set) and manufacturers IFUs for the instruments in the D&C set were requested. In response to the request, surgical director (Director) #2 stated they were unable to provide the manufacturer’s IFU for four of the surgical instruments in the D&C set. The instruments without a manufacturer’s IFU included an Adair Allis forceps (multi-toothed forceps used to grasp tissue), an Amico Allis forceps, a pair of Metzenbaum scissors (scissors used to cut delicate tissue), and a uterine probe (instrument used to measure the depth and direction of the uterus). This observation contrasted with the facility’s SPD Infection Control policy, which stated staff were to clean instruments in accordance with the manufacturer’s IFU. The observation also contrasted with the AORN Guideline for Instrument Cleaning, which stated surgical instrument manufacturers have determined the necessary steps required to decontaminate and sterilize surgical instruments, and these IFUs should be present and accessible to staff who reprocess the instruments. B. Interviews i. On 8/4/25 at 12:50 p.m., an interview was conducted with MA #1. MA #1 stated they did not know surgical instruments used for podiatry procedures needed to be reprocessed and sterilized. MA #1 stated they had been told the instruments used for podiatry procedures should be cleaned with Rapicide. MA #1 further stated they were unfamiliar with what a manufacturer’s IFU was, its purpose, how to access it, or why it was necessary. This contrasted with the AORN Guideline for Instrument Cleaning, which stated, surgical instruments should be cleaned according to the manufacturer’s IFU and, the manufacturer’s IFU should be given to and reviewed with staff who clean the instruments. ii. On 8/4/25 at 12:15 p.m. and on 8/6/25 at 2:41 p.m., interviews were conducted with surgical director (Director) #2. Director #2 stated surgical instruments should be reprocessed in accordance with the manufacturer’s IFU. Director #2 stated manufacturer IFUs were available in both paper and online formats, and SPD staff were able to easily access them when needed. Director #2 stated following the manufacturer’s IFUs was essential for patient safety since it ensured instruments were properly cleaned and prevented the transmission of infections. However, during the survey, the facility was unable to provide the manufacturer’s IFUs for four instruments in the D&C set when requested, which directly contrasted with Director #2’s earlier statement about their availability and ease of access. Additionally, Director #2 acknowledged the facility could not locate the manufacturer’s IFUs for the four instruments in the D&C set. Director #2 stated SPD staff relied on the manufacturer’s IFUs to determine the steps needed to properly reprocess surgical instruments. Director #2 further stated without the IFUs, it was not possible to properly clean those four instruments, and the instruments had to be pulled from the set entirely. Lastly, Director #2 stated that not having the manufacturer’s IFUs readily available for the surgical instruments posed significant patient safety risks. 52761”

    Rule C1206. Standard-level.

All 4 inspections in the last three years
Inspections on record
DateVisitWhat the record says
Sep 4, 2025Standard inspection3 deficiencies cited
Aug 7, 2025Standard inspection3 deficiencies cited
Aug 6, 2025Complaint inspectionNo deficiencies cited
Oct 22, 2024Complaint inspectionNo deficiencies cited

How do patients fare?

  • CMS gives no overall : “There are too few measures or measure groups reported to calculate a star rating or measure group score.”
  • Of the measures behind its , CMS counts against the national value: mortality, 0 better and 0 worse of 1; safety of care, 0 better and 0 worse of 1; readmission, 0 better and 0 worse of 2.
  • CMS gives no : “The number of cases/patients is too few to report a star rating.”
  • In CMS’s patient survey (Oct 1, 2024 to Sep 30, 2025): 74% rated it 9 or 10 out of 10, and 66% would definitely recommend it.
  • Infections, compared by CMS with the national benchmark (Oct 1, 2024 to Sep 30, 2025): C. diff infections, no different than national benchmark.
  • Deaths within 30 days, as CMS gives them (Jul 1, 2022 to Jun 30, 2025): pneumonia 18.1%. CMS gives no comparison with the national rate for them in this release.
  • Readmissions within 30 days, as CMS gives them (Jul 1, 2023 to Jun 30, 2025): pneumonia 17%. CMS gives no comparison with the national rate for them in this release.
  • After outpatient care, compared by CMS: unplanned hospital visits after a colonoscopy, no different than the national rate.
  • Emergency department patients spent a median of 117 minutes there before leaving (Oct 1, 2024 to Sep 30, 2025), and 1% left before being seen.
Ratings and measures, as published
MeasureRating
Overall ratingCMS’s overall hospital quality star rating, 1 to 5Not rated
Patient survey ratingCMS star rating from its survey of the hospital’s patients (HCAHPS), 1 to 5Not rated

Is it certified, and in good standing?

  • Medicare-certified critical access hospital since Jun 28, 2002.
  • Ownership: government - hospital district or authority.
  • It is not accredited by a private organisation, so the state carries out its routine inspections for Medicare.
  • Cited at in the last three years: it didn’t meet a whole condition of Medicare’s rules for hospitals.
  • Government - Hospital District or Authority.
Source:

CMS, Provider of Services File - Hospital & Non-Hospital Facilities. Released Oct 14, 2026. Updated quarterly.

CMS, Hospital General Information. Released Aug 13, 2026. Updated quarterly.

CMS, QCOR Hospital 2567 statements of deficiencies. Released Oct 20, 2026. Updated monthly.

Has it been penalized?

  • CMS doesn’t publish fines or other penalties for hospitals.
  • CMS’s HAC Reduction Program file has no result for it: the program covers general acute care hospitals Medicare pays under its inpatient prospective payment system.
  • None of the deficiencies cited in the last three years came from an inspection that included a complaint investigation.
Source:

CMS, Hospital-Acquired Condition (HAC) Reduction Program. Released Aug 13, 2026. Updated yearly.

CMS, Provider of Services File - Hospital & Non-Hospital Facilities. Released Oct 14, 2026. Updated quarterly.

CMS, QCOR Hospital 2567 statements of deficiencies. Released Oct 20, 2026. Updated monthly.

What do patients say about their care?

  • CMS doesn’t publish staffing levels for hospitals.
  • 98% of its health care workers got a flu shot (Oct 1, 2024 to Mar 31, 2025).
Source:

CMS, Patient survey (HCAHPS) - Hospital and Timely and Effective Care - Hospital. Released Aug 13, 2026. Updated quarterly.

Who owns it?

  • Huerfano County Hospital District runs it.
  • 8 owners or officers are people: Brenda J Parnell (corporate officer); John Davis (corporate director, 0%); Maurice E Heikes (corporate officer); Nancy M Nielsen (corporate director, 0%); Kay Whitley (corporate director, 0%); Kay Whitley (managing employee (on the payroll), 0%); Joann Ugolini (corporate officer); Jill Davis Homerding (corporate director, 0%).
  • CMS’s Provider of Services file records no change of ownership.
  • No private-equity firm among the owners CMS lists.
  • No real-estate investment trust among the owners CMS lists.
Source:

CMS, Hospital All Owners and Hospital Enrollments. Released Sep 29, 2026. Updated monthly.

CMS, Provider of Services File - Hospital & Non-Hospital Facilities. Released Oct 14, 2026. Updated quarterly.

How does it compare nearby?

  • No other hospital CMS lists is in Huerfano County.
Source:

CMS, Hospital General Information. Released Aug 13, 2026. Updated quarterly.

What the record doesn’t say

  • CMS doesn’t publish fines or other penalties for hospitals, so none are shown. The one payment cut CMS publishes for each hospital, under its Hospital-Acquired Condition Reduction Program, is shown where it applies.
  • Only complaints that led to a citation appear; complaints that didn’t aren’t published.
  • Most hospitals are accredited by a private organisation (The Joint Commission, DNV and others) whose routine inspections stand in for the state’s; those reports aren’t public, and QCOR holds only the state’s surveys: no inspection on record here doesn’t mean none took place.
  • QCOR says its hospital inspection data are complete only through September 17, 2026, while it moves to a new system.
  • CMS doesn’t publish staffing levels for hospitals.
  • In its September 2026 release CMS gives no comparison with the national rate for death and readmission rates, though it gives the rates.

Sources

If you believe something here is wrong, a correction starts with the agency whose record this copies: CMS. CMS’s own record is on Care Compare. If Hearth Record copied something wrongly, it will fix it and log the correction publicly, with its date: how corrections work.

Source:

This copy of the record was made on Nov 5, 2026.

From the hospital

The public record above comes first. Anything the hospital adds will appear here, below it, and say who wrote it.

Replies

None. Replies aren’t open yet. When they open, the hospital will be able to answer any finding for free, and the reply will show beside that finding, unedited and dated.

Paid listing

None. Paid listings aren’t open yet. When they open, anything paid for will say “Paid by the hospital”, and paying will never change a finding, a rating or the order of results.

How to read a record

Four things every record does, shown on an example record made up for this guide.

An example record, made up for this guide

An example nursing home

Made up for this guide: no real place is shown

Not fully inspected in over two years (CMS flag)

11 health citations at the latest inspection cycle

The state average is 14.3.

Source:

CMS, State and US Averages and Health Deficiencies. Released Oct 28, 2026. Updated monthly.

From the homeNone yet. Replies and paid listings aren’t open, and when they open they will sit here, below the record.

1 of 4

Every fact names its source.

Who published it, when, and how often it changes sit beside each fact, with a link to the agency’s own file.

Sign in

A free account keeps your watch list, shortlists, comparisons and saved searches on every device, and can email you when something you watch changes. Browsing never needs one.