Hearth Record

California Pacific Medical Ctr-Davies Campus Hosp

An acute care hospital in San Francisco, California 94117

601 Duboce Avenue, San Francisco, California 94117. (415) 600-6000.

  • Medicare payments cut under the HAC Reduction Program (fiscal year 2026)
CMS’s own record, on Care Compare

Watch and the shortlist are kept with a free account, on every device. Your watch list. CMS’s own record is on Care Compare.

The short answer

Record last released by CMS on Oct 20, 2026.

The last 24 months 12 deficiencies in 1 month of the last 36. Last cited Feb 2024. Most serious: Condition-level. Every month

Each figure’s source sits beside it, in its section below.

What these words mean4
Star ratings
CMS rates some kinds of place from 1 to 5 stars, more stars meaning better on CMS’s own measures for that kind: for a nursing home, its health inspections, staffing and quality measures. A rating is CMS’s summary of those measures; it doesn’t promise good care. Source: CMS, Care Compare and the Five-Star Quality Rating System.
Inspection (survey)
A visit by state inspectors, often unannounced, who check a place against the rules it must meet. For nursing homes and other places Medicare pays, CMS calls these visits surveys: a standard survey of a nursing home comes at least every 15 months, and a complaint survey whenever a complaint calls for one. Source: CMS; 42 CFR 488.308.
Deficiency, citation, violation
What inspectors write up when a place didn’t meet a rule: the rule, what they saw, and when. CMS calls it a deficiency; states may say citation or violation. It is the inspectors’ finding, not a court’s, and the place is usually asked for a plan to correct it. Source: CMS, statement of deficiencies (Form CMS-2567); each state’s licensing agency.
Condition-level deficiency
For hospices, home health agencies, hospitals and dialysis facilities, CMS writes deficiencies at two levels. Standard is the usual one; condition-level is the more serious, when a problem is serious enough that the provider doesn’t meet a whole condition of taking part in Medicare. Source: CMS, State Operations Manual.

What did inspectors find?

The last inspection on record was on Feb 15, 2024: a complaint inspection.

12 deficiencies cited in the last three years, 3 of them at condition level, the most serious.

3 deficiencies at condition level, the more serious of CMS’s two levels

Source:

CMS, QCOR Hospital 2567 statements of deficiencies. Released Oct 20, 2026. Updated monthly.

When those deficiencies happened

12 deficiencies in 1 month of the last 36. Last cited Feb 2024. Most serious: Condition-level. The last 3 years, to Nov 5, 2026.

12 deficiencies by month over the last 3 years. Each cell is one month.
JanFebMarAprMayJunJulAugSepOctNovDec
2023 Dec
2024 JanFebMarAprMayJunJulAugSepOctNovDec
2025 JanFebMarAprMayJunJulAugSepOctNovDec
2026 JanFebMarAprMayJunJulAugSepOctNov

Hover or focus a month to read it.

No visit on record Visited, nothing cited A stronger orange is more serious, on its source’s own levels, read onto four bands: from the least serious it publishes to the most
Source:

Hearth Record drew this from the dates and levels in the source’s own records.

Each deficiency, as cited

Rule titles as CMS’s inspectors cite them, set in sentence case.

Source:

CMS, QCOR Hospital 2567 statements of deficiencies. Released Oct 20, 2026. Updated monthly.

Feb 15, 2024: complaint inspection12 deficiencies
  • Governing Body

    The inspectors’ words, 365 words

    “GOVERNING BODY CFR(s): 482.12 There must be an effective governing body that is legally responsible for the conduct of the hospital. If a hospital does not have an organized governing body, the persons legally responsible for the conduct of the hospital must carry out the functions specified in this part that pertain to the governing body ... This Condition is not met as evidenced by: 28225 Based on observation, interview and record review, the facility failed to ensure Condition of Participation: Governing Body §482.12 was met for (Healthcare System’s Name), [Facilities Group Name affiliated with (three) separately certified hospitals], Hospital (H) 2, when: 1. Governing Body did not maintain oversight of rectal ultrasound probes (probe inserted into the rectum which uses sound waves to produce images during a surgical procedure) provided by (Contractor Name). This failure resulted in the potential exposure for 33 patients at risk to be exposed to infectious diseases such as hepatitis (inflammation of the liver caused by infection) and/or human immunodeficiency virus (HIV- a virus that attacks the immune system) . (Refer A-083) 2. Governing Body did not ensure rectal probe provided by (Contractor Name) was cleaned and disinfected according to the manufacturer’s instructions for use (MIFU, provide detailed instructions on how equipment should be used, maintained, and stored properly) and facility policy. This failure resulted in the potential exposure for 33 patients at risk to be exposed to infectious diseases such as hepatitis (inflammation of the liver caused by infection) and/or human immunodeficiency virus (HIV- a virus that attacks the immune system). (Refer A-084) 3. Governing Body did not ensure contractor responsibilities and services to be provided with rented rectal probes to (Healthcare System’s Name), ([Facilities Group Name] affiliated with (three) separately certified acute care hospitals in (Name) area], Hospital 2, were specified on the contract agreement. This failure resulted in the potential exposure to approximately 33 patients at risk to be exposed to infectious diseases such as hepatitis (inflammation of the liver caused by infection) and/or human immunodeficiency virus (HIV- a virus that attacks the immune system). (Refer A-085) The cumulative effects of the systemic failures resulted in the facility’s inability to provide quality healthcare in a safe environment.”

    Rule A0043. Condition-level. From a complaint.

  • Infection Prevention Control Abx Stewardship

    The inspectors’ words, 339 words

    “INFECTION PREVENTION CONTROL ABX STEWARDSHIP CFR(s): 482.42 The hospital must have active hospital-wide programs for the surveillance, prevention, and control of HAIs and other infectious diseases, and for the optimization of antibiotic use through stewardship. The programs must demonstrate adherence to nationally recognized infection prevention and control guidelines, as well as to best practices for improving antibiotic use where applicable, and for reducing the development and transmission of HAIs and antibiotic resistant organisms. Infection prevention and control problems and antibiotic use issues identified in the programs must be addressed in collaboration with the hospital-wide quality assessment and performance improvement (QAPI) program. This Condition is not met as evidenced by: 33922 The facility failed to ensure the Condition of Participation for Infection Prevention and Control and Antibiotic Stewardship Programs §482.42 was met when: 1. Rectal ultrasound probes (probe inserted into the rectum which uses sound waves to produce images during a surgical procedure) were not cleaned and disinfected according to the manufacturer’s instructions for use (IFU) and facility policy. (Refer to A-0749 Finding 1) 2. Staff failed to follow the facility’s Standard Work (a document with step-by-step instructions) and manufacturer’s instructions for use (IFU) when cleaning and disinfecting a rectal ultrasound probe (probe inserted into the rectum which uses sound waves to produce images during a surgical procedure), after a procedure. (Refer to A-0749 Finding 2) 3. One rusty cylinder tank of “compressed air (air that is pressurised to greater than atmospheric pressure)” was observed in the Operating Room. (Refer to A-0750) 4. Facility leadership failed to oversee the process of cleaning and disinfecting rectal ultrasound probes and failed to identify the process for cleaning and disinfection of rectal ultrasound probes did not adhere to nationally recognized guidelines. (Refer to A-0772) 5. The facility’s Infection Control Plan was not specific to the population served and the services provided at the hospital. (Refer to A-0786) The cumulative effects of these failures resulted in the facility’s inability to meet the Condition of Participation for Infection Prevention and Control and Antibiotic Stewardship Programs.”

    Rule A0747. Condition-level. From a complaint.

  • Surgical Services

    The inspectors’ words, 413 words

    “SURGICAL SERVICES CFR(s): 482.51 If the hospital provides surgical services, the services must be well organized and provided in accordance with acceptable standards of practice. If outpatient surgical services are offered the services must be consistent in quality with inpatient care in accordance with the complexity of services offered. This Condition is not met as evidenced by: 28225 Based on observation, interview and record review, the facility failed to ensure Condition of Participation: Surgical Services §482.51 was met when: 1. Rectal ultrasound probes (probe inserted into the rectum which uses sound waves to produce images during a surgical procedure) were cleaned and disinfected according to the manufacturer’s instructions for use (IFU) and facility policy. As a result of this failure, thirty-three patients were potentially exposed to infectious diseases such as hepatitis (inflammation of the liver caused by infection) or human immunodeficiency virus (HIV- a virus that attacks the immune system). (Refer A=0951 Finding #1) 2. Staff did not follow the facility’s Standard Work (a document with step-by-step instructions) and manufacturer’s instructions for use (IFU) when cleaning and disinfecting a rectal ultrasound probe (probe inserted into the rectum which uses sound waves to produce images during a surgical procedure), after a procedure. This failure resulted in the potential that the probe was not adequately disinfected. (Refer A=0951 Finding #2) 3. One rusty cylinder tank of compressed air (air that is pressurized to greater than atmospheric pressure) was in Operating Room 5. This deficient practice had the potential for cross contamination (transfer of harmful bacteria from one person, object or place to another) to happen. (Refer A=0951 Finding #3) 4. Sterile surgical instruments (tools used to perform surgery) were stored to prevent contamination when rigid instrument cases were stored on top of soft wrapped instrument packs. This failure resulted in the potential for contaminated surgical instruments. (Refer A=0951 Finding #4) 5. Total of six (6) expired plastic containers of sterile water humidifier with expiration date of “2/8/23” were stored in the bottom of the three-tiered rack inside the Clean Room of the Post Anesthesia Care Unit (PACU, is a critical care unit and specialty that focuses on the recovery and treatment of patients immediately following surgical procedures and anesthesia). This failure resulted in the potential cross contamination (transfer of harmful bacteria from one person, object or place to another) to happen. (Refer A=0951 Finding #5) The cumulative effects of the systemic failures resulted in the facility’s inability to provide quality healthcare in a safe environment.”

    Rule A0940. Condition-level. From a complaint.

  • Contracted Services

    The inspectors’ words, 3,904 words

    “CONTRACTED SERVICES CFR(s): 482.12(e) The governing body must be responsible for services furnished in the hospital whether or not they are furnished under contracts. The governing body must ensure that a contractor of services (including one for shared services and joint ventures) furnishes services that permit the hospital to comply with all applicable conditions of participation and standards for the contracted services. This Standard is not met as evidenced by: 28225 Based an observation, interview and record review, the Governing Body for (Healthcare System’s Name), for [Facilities Group Name affiliated with (three) separately certified hospitals], Hospital (H) 2 failed to maintain oversight of rectal ultrasound probes (probe inserted into the rectum which uses sound waves to produce images during a surgical procedure) provided by (Contractor Name) . This failure resulted in the potential exposure for 33 patients to infectious diseases such as hepatitis (inflammation of the liver caused by infection) and/or human immunodeficiency virus (HIV- a virus that attacks the immune system) Findings: During a group interview on 2/5/24, at 10:07 AM, at (Hospital) H 1 with the Director of Accreditation and Licensing (DAL), Manager of Accreditation and Licensing (MAL), Director of Quality, Patient Safety, and Infection Control (DQI), Chief Nursing Executive (CNE), and Infection Control Manager (ICM), the DQI stated, in November 2023 the facility received an email notification from (Healthcare System’s Name) there may be potential patients at risk regarding infection control issues with the use of the ultrasound rectal probes. The DQI stated, the email contained instruction to reach out to the local managers (of hospitals operating under (Healthcare System’s Name), [Facilities Group Name affiliated with (three) separately certified hospitals] to evaluate the process. The DQI stated, the facility’s use of the ultrasound rectal probe dated back ten years and it was a rented equipment. The DQI further stated, that before the hospital was notified of the rectal probe disinfection issue, the staff performed low level disinfection (LLD, a process that kills bacteria and some viruses on items that only come in contact with intact skin) prior to using the probe and the re-processing (cleaning, disinfection, and sterilization of reusable medical equipment/devices) of the ultrasound rectal probe did not include high-level disinfection (HLD, a cleaning process which achieves elimination of all microorganisms in or on medical device, except for small number of bacterial spores). The DQI further stated, the facility suspended the use of the rectal probe, identified the patients at risk, sent notification letters to patients at risk, and notified local and state agencies. The use of the rectal probe was re-launched sometime in December 2023. During a review of facility’s document titled, “(Contractor’s Name) Rectal Probe Review Timeline”, received 2/5/24 indicated, “11/13/2023, 9:55 AA, Systems (Healthcare System) e-mail inform and action needed - HLD rectal probes, sites need to take immediate action to stop the use of inadequate disinfected devices on patients and implement an effective HDL process. 1. Identify all your usable devices that contact mucous membranes or sterile body sites., 2. Stop use of all devices identified in item one with inadequate HDL., 3. Investigate the current process and ensure appropriate HDL sterilization processes in place for MIFU., 4. Perform and document a risk assessment., 5. Resume use of these devices only when an appropriate disinfection* process is in place ... Please note : We are in the process validated facts and may have additional guidance as we learn more information we have reached out the company and are awaiting their response ... 11/14-15/2023 ... IC (Infection Control) fact finding and investigation + (plus) suspend use of probes ... 11/30/2023, Initiate Training, Education and Communication to Staff + local audits ... 12/11 and 15/2023, Relaunch of (Contractor’s Name) (rectal) Probe at H 1, H 2, H 3 (12/15) ... 1/8/2024, [Facilities Group Name affiliated with (three) separately certified hospitals] Notify CDPH ... 2/5/24, To date ... 179 [ Facilities Group Name affiliated with (three) separately certified hospitals] patients were notified ... “ Review of the facility letter sent to the State Agency [SA, California Department of Public Health (CDPH, ensures compliance with state licensing laws and federal certification regulations)], dated 1/8/24 indicated, “Notice of rectal probe disinfection process issue... we have newly learned that the disinfection process performed on this equipment did not meet the required high level disinfection (“HDL”) process for reusable rectal probes ... Immediate actions taken: We suspended the use of all reusable rectal probes ... 2. We ensured that an appropriate level of disinfection or sterilization is in place ... Next steps: 1. Patients identified as having a potential exposure are being notified ... 2. We are offering these patients free Hepatitis C (liver infection caused by the hepatitis C virus), Hepatitis B (inflammation of the liver by the hepatitis B virus) and HIV (HIV- a virus that attacks the immune system) tests.” During an observation and interview on 2/6/24 at 8:49 AM, at H 1, with VR, in the Operating Room (OR, sterile location where surgical procedures were performed) suite, VR stated, rectal probe model 8848 was used during the procedure (2/6/24). VR stated, whenever a rectal probe was needed for a procedure, he or another VR brought the rectal probe from the contractor facility to the hospital [(one of (three) separately certified hospitals) where it was scheduled to be used. VR stated, before the hospital was notified of the rectal probe disinfection issue, after the procedure he (VR) wiped the rectal probe thoroughly with the disinfectant wipe, put it inside the rectal probe container, and brought it back with him to the contractor facility. VR stated, he’s brought the rectal probe from the contractor facility to the hospital for the procedures since “a few years”. VR said he learned (was trained) how to disinfect the rectal probe “on the job”. VR stated, he had no documentation (from contractor) to verify competency (ability to do something successfully, effectively, or efficiently) with disinfection/decontamination of the rectal probe. VR further stated, after the rectal probe was brought back to the contractor facility, he did not know if further decontamination of the rectal probe was done at the contractor facility or before the rectal probe was reused for another procedure. Review of the facility,(Healthcare System’s Name), [Facilities Group Name affiliated with (three) separately certified hospitals], Policy and Procedures (P&P) titled, “Vendors and Sales Representatives, Special Instruments/Equipment /Supplies Guidelines in the Surgical Services Department”, revised 6/16/22 indicated, “Purpose to outline responsibilities and provide guidelines for vendor activities involving the Surgical Services department ... Scheduling and Approvals ... [Facilities Group Name affiliated with (three) separately certified hospitals] Surgical Services arranging ... 1 ... b. vendors are notified in a timely manner to allow for instrument and supplies to be prepared for the case ... 3 .... e. Manager/Supervisor/Service Leader or designee will arrange for staff education with the vendor prior to using new or unfamiliar instruments or equipment... f. Equipment or instruments may not be used during a procedure without appropriate education and or support for staff ... Sterile Processing Departments, 1 ... vendors must check in at SPD prior to entry. 2. The instrument/implant company (contractor) is responsible for delivery and pickup of instruments and implants ... 5. Pre-Procedure sets will arrive at least 24-48 hours ... a. Instruments/implant sets must be inspected, cleaned, and decontaminated, and sterilized by [Facilities Group Name affiliated with (three) separately certified hospitals] staff prior to use ... Post Procedure, 1. SPD staff will process sets through the washer/decontaminator or hand wash, if needed. Inspect for cleanliness and organize the instruments and sets. SPD staff will then place them in a specified card/area for vendor pickup ... The Operating Room ... 8 The Circulating RN ... Confirm, prior to the start of the procedure that the loaner instruments have been processed at [Facilities Group Name affiliated with (three) separately certified hospitals] ...” During an interview on 2/6/24 at 1:30 PM at H 1 with (Medical Director Pharmacy and Infection Control for [Name Healthcare System] (MDIC) and Director of Accreditation and Licensing (DAL) as scribe (wrote (for facility) questions asked and answers given during interview), the MDIC stated, he had oversight for (Healthcare System’s Name). He stated, the contractor would come in (on scheduled procedures dates) with (rectal) probe attached to the machine and told (facility) equipment was ready to go. MDIC stated, the rectal probe disinfection issue was discovered when (date not mentioned) a hospital that was part of the Healthcare System wanted to own/buy the equipment. A representative (name not mentioned) from (Contractor Name) came in and asked “why are you not doing high-level disinfection (HLD, a cleaning process which achieves elimination of all microorganisms in or on medical device, except for small number of bacterial spores)?” (Contractor Name) was not doing leak testing. MDIC stated, (Contractor Name) did not have a policy on disinfection. A new representative inquired why was HLD not being done. (Healthcare System Name) received (date not given) the report from a (Healthcare System Name) staff (identifier not mentioned). The MDIC further stated, “As soon as we learned, we stopped using (rectal probe). We set up the process- analyzed, identified the system gap related to the (Contractor Name) and set up a process, collected data, who was using the probes, the type of probes used. We developed a standard work for the specific probes ...” The MDIC stated, 450 patients from the whole Healthcare System were affected. The problem was presented to Biomed (biomedical department ensures medical devices and equipment are in good repair, functions effectively and are efficient.) as a whole package- machine (rectal probe connected into ultrasound system); went to Biomed as a piece of equipment, looked at it as a single package. They (Biomed) thought it (rectal probe) was no different than an external equipment, slipped under the radar because of the way the company presented it. MDIC stated, expectation was if it goes in the orifices, it needs HLD. We missed it - the need for HLD (information on duration not done not mentioned) for the rectal probes. During a review of facility’s document with 8 (eight) pages, not titled, printed 2/50 (sic)/2024, document indicated columned lists information with [ Facilities Group Name affiliated with (three) separately certified hospitals], Patient (s) Name, Medical Record Number, Date of Birth, Date of Procedure, Procedure, Address, Medical Doctor’s Name(s), Page 8 indicated Total: 179 (total number of patients affected with rectal probe disinfection issue) ...” During an interview on 2/7/24 at 4 PM, at H 1, with DAL, DAL stated it was she who notified SA regarding the rectal probe disinfection issue. The 8 (eight) Pages document was the list of patients affected with rectal probe disinfection issue for [Facilities Group Name affiliated with (three) separately certified hospitals], Hospital (H)1, H 2, and H 3. Also, individuals(s) with authority and responsibilities for the conduct of the hospital and patient care (governing body) were the same for [(Healthcare System’s Name), [Facilities Group Name affiliated with (three) separately certified hospitals] H 1, H 2, and H 3; and all facility policies and procedures for H 1, H 2, and H 3 were (Healthcare System’s Name), [Facilities Group Name affiliated with (three) separately certified hospitals] policies and procedures. During a video call interview on 2/9/24 at 10:14 AM, at H 1 surveyors reviewed facility contract agreement packet titled, “Contract #SC14548, [(Name) Healthcare System], Sixth Amendment”, Renewed 4/30/2023, with Senior Director (Strategic Sourcing) (SDSS) for [(Name) Healthcare System] and Strategic Sourcing Manager for Contracting (SSMC), DAL was scribe. SDSS confirmed she signed contract agreement between “customer” [(Name) Healthcare System] and “contractor” [(Contractor Name) contractor who provided rectal probes)]. SDSS verified initial contract date was April 18, 2016, and expiring on 4/30/24. SSMC stated contract had auto renewal option. SDSS stated, for [(Name) Healthcare System], [Facilities Group Name in (Name) Area affiliated with (three) separately certified acute care hospitals] who use the same services, we [(Name) Healthcare System] employees responsible for contract agreement(s)] try to consolidate vendors [contractor(s)]. This one (contract agreement) started before I started with [(Name) Healthcare System]. SDSS confirmed contract applied to all [(Name) Healthcare System], [Facilities Group Name in (Name) Area affiliated with (three) separately certified acute care hospitals]. Surveyors reviewed with SDSS and SSMC contract agreement, “Page 1 of 20 ... AGREEMENT, I. SERVICES COVERED, 1. Services/ Products/Scope of Work” (Contractor) responsibilities and services to be provided for rented rectal probes (models not indicated), to (Healthcare System’s Name), ([Facilities Group Name] affiliated with (three) separately certified acute care hospitals in (Name) area] were not indicated/specified. SDSS stated, I think this contract has a gap. There should be additional amendment. SSMC stated, I’m not seeing amendments, looking for updates in the contracts, changes in the services ... Sixth amendment: current executed version, did not have vendor responsibilities, (in exhibit E, that should have been included in the current contract). SDSS stated, Basic HLD (high level disinfection) for scopes (general policy) - that policy requires that we perform HLD for items from vendors, checked by biomed. IC (Infection Control) department should be involved but this device (rented rectal probe) was not on the list of things that need HLD. It is the hospital’s responsibility to apply the IFU (instructions for use). It’s the directors in each department that is responsible for following the MIFU (manufacturer’s instructions for use). During an interview on 2/9/24 at 2:06 PM, at H 1, with Chief Operating Officer (COO) and DAL as scribe, COO stated, he was one of a group of individuals who had oversight (authority and responsibilities (governing body) for the conduct of the hospital and patient care) for [(Name) Healthcare System] [Facilities Group Name affiliated with (three) separately certified acute care hospitals] He confirmed each hospital had its own provider (Medicare) number. COO stated the rectal probe disinfection issue was not usual by definition - confirmed it was an unusual occurrence. The COO stated that before reporting (to CDPH), “we wanted to investigate to make sure what was happening. We had to determine whether patients were affected, which hospitals were using (the rectal probe), had to determine facts.” COO stated, with routine negotiation (of contracts) Board of Directors [(Name) Area Operating Board] were not involved in what was included in the contract. [(Name)Healthcare] “System” was responsible for contracts (agreement) with (Contractor) (effective 4/18/16, renewed 4/18/2021); but, he (COO) would have input. The COO stated, “The (Contractor) (vendor representative) is not responsible for the HLD, it’s the hospital’s job. Our policy indicates, in general, we’re supposed to do it (HLD). The HLD is our responsibility, we’re supposed to sterilize prior to use, to prevent transmission of infections. There was belief that we were doing what we were supposed to do in cleaning it (rectal probe), and equipment used for patients. HLD - that is our responsibility and we failed to do that.” The COO stated the directors of surgical services [DSS) - (Representatives for Quality Assurance are responsible for ensuring MIFU is followed. COO stated, regarding rectal probe disinfection issue not included in Quality Assurance Performance Improvement (QAPI) minutes for November to December 2023, January 2024 - “we have not gotten there yet, but it does not mean we did not discuss it.” During a concurrent observation and interview with the Scrub Technician (ST 2) on 2/14/24 at 8:16 a.m. in the operating room (OR), ST 2 stated the surgical procedure had just finished and he was beginning the “pre-cleaning” process for the rectal ultrasound probe used in the procedure. During the pre-cleaning process, ST 2 was observed wiping the probe with disinfecting wipes beginning at the tip of the probe moving toward the top of the probe and ending at the cord which connects to the ultrasound monitor (in a dirty to clean direction). After wiping the probe, ST 2 placed the probe into a bin and stated, “Now it needs to dry for three minutes.” ST 2 left the probe in the bin for three minutes while performing other tasks. ST 2 then stated, it had been three minutes and he covered the bin with a red bag. The bin containing the probe was then sent in the elevator to the Sterile Processing Department (SPD an area within the hospital in which medical/surgical supplies and equipment, are cleaned, prepared, processed, stored, and issued for patient care). During a concurrent observation and interview with the Sterile Processing Technician (SPT 4) on 2/14/24 at 8:26 a.m. in the SPD, SPT 4 stated, he had just received the probe from the OR and was beginning the High-Level Disinfection process (a cleaning process which achieves elimination of all microorganisms in or on a medical device, except for small numbers of spores). SPT 4 stated a leak test (a process required to protect patients from infection that could result from leaks in the device and also protects the device from damage) was required for the probe to ensure there were no small holes in the probe. SPT 1 placed the leak tester on the end of the probe cord and pumped the pressure to a reading of 150 mm (millimeter of mercury- a measurement used to record pressure). Immediately after obtaining a pressure reading of 150 mm, SPT 1 stated, “It’s holding strong, so it passed the leak test.” SPT 4 did not monitor the pressure reading during the leak test for a specific amount of time. During an interview on 2/14/24 at 10:10 a.m. with the Infection Prevention Manager (IPM), IPM stated the facility was part of a [hospital system] who had multiple hospitals in the state; in addition, the facility was part of a small group of three hospitals which shared a governing body and had a shared Infection Prevention Department. IPM stated she had oversight of three hospitals and there was a dedicated Infection Preventionist (IP) at each hospital. IPM further stated the three hospitals shared another IP who had oversight of surgical services for all three hospitals. IPM stated, in November 2023, she received a call from the Clinical Process Improvement Consultant (CPIC) for the facility’s hospital system regarding the facility’s use of rectal ultrasound probes. IPM stated, she was unaware if the facility used the rectal ultrasound probes, and she sent out an email to the Surgical Services Department at the facility to inquire about the use of the probes. IPM stated the hospital used the Spaulding Classification System (a nationally recognized infection control standard which is used to define the minimum level of disinfection required for a medical device) to determine how medical devices should be cleaned. IPM stated rectal ultrasound probes required High-level Disinfection (HLD- a cleaning process which achieves elimination of all microorganisms in or on a medical device, except for small numbers of bacterial spores) because the probe came in contact with mucous membranes (soft lining of body cavities and canals that lead to the outside of the body). IPM stated, she received an email response from the Surgical Services Manager who confirmed the rectal ultrasound probes were used in the operating room (OR) and reported the cleaning and disinfecting procedure did not include HLD. IPM stated she was unaware of the facility’s process for cleaning and disinfecting the probes until that date. IPM stated, at that time, the facility was instructed to stop the use of the probes as the cleaning and disinfection process was inadequate. During an interview on 2/14/24 at 1:10 p.m. with the Surgical Services Manager (MSS 3), MSS 3 stated the facility performed surgical procedures using a rectal ultrasound probe. MSS 3 stated the facility contracted with a vendor who brought the rectal ultrasound probe to the Operating Room (OR) to be used for a procedure and OR staff cleaned the probe with a disinfecting wipe, covered the probe with a plastic sheath, and used it during the procedure. MSS stated, after the procedure, OR staff removed the plastic sheath, cleaned the probe with a disinfecting wipe, and gave the probe back to the vendor. MSS 3 confirmed the facility used the Spaulding Classification System to determine how medical devices should be cleaned. MSS 3 confirmed, according to Spaulding Classification, rectal ultrasound probes come in contact with mucus membranes (soft lining of body cavities and canals that lead to the outside of the body) and required High-Level Disinfection at a minimum. MSS 3 stated she had worked at the facility for approximately four years and stated, “This is the way it was always done so I didn’t question it.” MSS 3 stated the facility was instructed to stop the use of the probes until further notice. During an interview on 2/14/24 at 2:42 p.m. with the Infection Prevention Registered Nurse (IP 1), IP 1 stated the IFU for the disinfecting wipes indicated a “wet time” of three minutes which meant the device should be maintained wet with the disinfecting product for three minutes and then dried with a cloth. IP 1 stated staff were expected to follow manufacturer’s IFU for all medical devices, for cleaning and disinfecting products. IP 1 further stated, it was his understanding that the rectal ultrasound probe manufacturer IFU allowed for low- level disinfection (a process that kills bacteria and some viruses on items that only come in contact with intact skin). IP 1 confirmed rectal ultrasound probes come in contact with mucus membranes and should be, at minimum, HLD according to the facility’s policy. During an interview on 2/15/24 at 9:30 a.m. with the Clinical Process Improvement Consultant (CPIC) for the facility’s hospital system, CPIC stated she worked for [hospital system name] which owned multiple hospitals in the state and the facility was a system hospital. CPIC stated, in November 2023, she received a concern from a staff member at a different hospital related to cleaning and disinfecting rectal ultrasound probes, so she reached out to all system hospitals to determine what their current process was. CPIC stated it was determined the facility was renting the rectal ultrasound probes from [vendor]. CPIC further stated, it was determined the facility was not cleaning and disinfecting the rectal ultrasound probes adequately. CPIC stated rectal ultrasound probes were considered semi-critical devices (any device that comes in contact with a mucus membrane) and required HLD, at a minimum. CPIC confirmed the facility was not performing HLD on these devices. CPIC stated the facility was instructed to stop using the rectal ultrasound probes until an investigation was conducted. During a concurrent interview and record review on 2/15/24 at 3:45 p.m. with the Director of Accreditation and Licensing (DAL), the “List of [hospital] Patient Notification” was reviewed. DAL stated the facility identified a list of patients who had procedures using the rectal ultrasound probe and may have been affected by the failure to HLD the probes. DAL stated, the facility sent notification letters to all patients on the list. The list included a total of thirty-three patients. During a review of the facility (Healthcare System’s Name), [Facilities Group Name affiliated with (three) separately certified hospitals], document titled, “Infection Prevention and Control Plan,” dated 3/16/23, indicated, “Geographical Location, [Facilities Group Name affiliated with (three) separately certified hospitals], is a group of (Name ) area acute care facilities with 585 beds ... [Facilities Group Name affiliated with (three) separately certified hospitals], provides tertiary (high level of specialized care) care services for ... California ... Authority and Responsibilities, The Governing Body and the [hospital] Infection Prevention and Control Committee members have the overall authority and responsibility for the Infection Prevention and Control Program...””

    Rule A0083. Standard-level. From a complaint.

  • Contracted Services

    The inspectors’ words, 4,374 words

    “CONTRACTED SERVICES CFR(s): 482.12(e)(1) The governing body must ensure that the services performed under a contract are provided in a safe and effective manner. This Standard is not met as evidenced by: 28225 Based on observation, interview and record review, the Governing Body for (Healthcare System’s Name), for [Facilities Group Name affiliated with (three) separately certified hospitals], Hospital (H) 2 failed to ensure rectal probe provided by (Contractor Name) was cleaned and disinfected according to the manufacturer’s instructions for use (MIFU, provide detailed instructions on how equipment should be used, maintained, and stored properly) and facility policy. This failure resulted in the potential exposure for 33 patients at risk to be exposed to infectious diseases such as hepatitis (inflammation of the liver caused by infection) and/or human immunodeficiency virus (HIV- a virus that attacks the immune system). Findings: During a group interview on 2/5/24, at 10:07 AM, at (Hospital) H 1 with the Director of Accreditation and Licensing (DAL), Manager of Accreditation and Licensing (MAL), Director of Quality, Patient Safety, and Infection Control (DQI), Chief Nursing Executive (CNE), and Infection Control Manager (ICM), the DQI stated, in November 2023 the facility received an email notification from (Healthcare System’s Name) there may be potential patients at risk regarding infection control issues with the use of the ultrasound rectal probes. The DQI stated, the email contained instruction to reach out to the local managers (of hospitals operating under (Healthcare System’s Name), [Facilities Group Name affiliated with (three) separately certified hospitals] to evaluate the process. The DQI stated, the facility’s use of the ultrasound rectal probe dated back ten years and it was a rented equipment. The DQI further stated, that before the hospital was notified of the rectal probe disinfection issue, the staff performed low level disinfection (LLD, a process that kills bacteria and some viruses on items that only come in contact with intact skin) prior to using the probe and the re-processing (cleaning, disinfection, and sterilization of reusable medical equipment/devices) of the ultrasound rectal probe did not include high-level disinfection (HLD, a cleaning process which achieves elimination of all microorganisms in or on medical device, except for small number of bacterial spores). The DQI further stated, the facility suspended the use of the rectal probe, identified the patients at risk, sent notification letters to patients at risk, and notified local and state agencies. The use of the rectal probe was re-launched sometime in December 2023. During a review of facility’s document titled, “(Contractor’s Name) Rectal Probe Review Timeline”, received 2/5/24 indicated, “11/13/2023, 9:55 AA, Systems (Healthcare System) e-mail inform and action needed - HLD rectal probes, sites need to take immediate action to stop the use of inadequate disinfected devices on patients and implement an effective HDL process. 1. Identify all your usable devices that contact mucous membranes or sterile body sites., 2. Stop use of all devices identified in item one with inadequate HDL., 3. Investigate the current process and ensure appropriate HDL sterilization processes in place for MIFU., 4. Perform and document a risk assessment., 5. Resume use of these devices only when an appropriate disinfection* process is in place ... Please note : We are in the process validated facts and may have additional guidance as we learn more information we have reached out the company and are awaiting their response ... 11/14-15/2023 ... IC (Infection Control) fact finding and investigation + (plus) suspend use of probes ... 11/30/2023, Initiate Training, Education and Communication to Staff + local audits ... 12/11 and 15/2023, Relaunch of (Contractor’s Name) (rectal) Probe at H 1, H 2, H 3 (12/15) ... 1/8/2024, [Facilities Group Name affiliated with (three) separately certified hospitals] Notify CDPH ... 2/5/24, To date ... 179 [ Facilities Group Name affiliated with (three) separately certified hospitals] patients were notified ... “ Review of the facility letter sent to the State Agency [SA, California Department of Public Health (CDPH, ensures compliance with state licensing laws and federal certification regulations)], dated 1/8/24 indicated, “Notice of rectal probe disinfection process issue... we have newly learned that the disinfection process performed on this equipment did not meet the required high level disinfection (“HDL”) process for reusable rectal probes ... Immediate actions taken: We suspended the use of all reusable rectal probes ... 2. We ensured that an appropriate level of disinfection or sterilization is in place ... Next steps: 1. Patients identified as having a potential exposure are being notified ... 2. We are offering these patients free Hepatitis C (liver infection caused by the hepatitis C virus), Hepatitis B (inflammation of the liver by the hepatitis B virus) and HIV (HIV- a virus that attacks the immune system) tests.” During an observation and interview on 2/6/24 at 8:49 AM, at H 1, with VR, in the Operating Room (OR, sterile location where surgical procedures were performed) suite, VR stated, rectal probe model 8848 was used during the procedure (2/6/24). VR stated, whenever a rectal probe was needed for a procedure, he or another VR brought the rectal probe from the contractor facility to the hospital [(one of (three) separately certified hospitals) where it was scheduled to be used. VR stated, before the hospital was notified of the rectal probe disinfection issue, after the procedure he (VR) wiped the rectal probe thoroughly with the disinfectant wipe, put it inside the rectal probe container, and brought it back with him to the contractor facility. VR stated, he’s brought the rectal probe from the contractor facility to the hospital for the procedures since “a few years”. VR said he learned (was trained) how to disinfect the rectal probe “on the job”. VR stated, he had no documentation (from contractor) to verify competency (ability to do something successfully, effectively, or efficiently) with disinfection/decontamination of the rectal probe. VR further stated, after the rectal probe was brought back to the contractor facility, he did not know if further decontamination of the rectal probe was done at the contractor facility or before the rectal probe was reused for another procedure. During a review of ( Manufacturer’s Name), titled, “Product Data Sheet, 8848 Endo Cavity Biplane Transducer”, dated July 2019, indicated, “The 8848 (Model) Endo Cavity Biplane Transducer [used to visualize (see) structures from inside body] design for use with the flex focus 1202 ultrasound system ... ideal for precise volume studies and guiding process and guiding prostate therapy ideal also for imaging the anterior and posterior compartments of the pelvic floor ... biplane imaging gives greater confidence in guiding therapy for a better orientation during needle placement expanded, sector allows complete visualization of the prostate ... perform quick reliable puncture and biopsy procedures with reusable needle guide ... unique fully immersible (capable of totally submerged in water without damage) transducer for easy sterilization ( a process that destroys or eliminates all forms of microbial life by physical or chemical methods) ... Reprocessing (a multistep process that includes cleaning, inspection, assembly, functional testing, disinfection, packaging, labeling, sterilization, and storage) ...Complete details and procedures can be found in Care and Cleaning ... Follow manufacturer’s instructions for use (MIFU) ...” Review of the facility,(Healthcare System’s Name), [Facilities Group Name affiliated with (three) separately certified hospitals], Policy and Procedures (P&P) titled, “Vendors and Sales Representatives, Special Instruments/Equipment /Supplies Guidelines in the Surgical Services Department”, revised 6/16/22 indicated, “Purpose to outline responsibilities and provide guidelines for vendor activities involving the Surgical Services department ... Scheduling and Approvals ... [Facilities Group Name affiliated with (three) separately certified hospitals] Surgical Services arranging ... 1 ... b. vendors are notified in a timely manner to allow for instrument and supplies to be prepared for the case ... 3 .... e. Manager/Supervisor/Service Leader or designee will arrange for staff education with the vendor prior to using new or unfamiliar instruments or equipment... f. Equipment or instruments may not be used during a procedure without appropriate education and or support for staff ... Sterile Processing Departments, 1 ... vendors must check in at SPD prior to entry. 2. The instrument/implant company (contractor) is responsible for delivery and pickup of instruments and implants ... 5. Pre-Procedure sets will arrive at least 24-48 hours ... a. Instruments/implant sets must be inspected, cleaned, and decontaminated, and sterilized by [Facilities Group Name affiliated with (three) separately certified hospitals] staff prior to use ... Post Procedure, 1. SPD staff will process sets through the washer/decontaminator or hand wash, if needed. Inspect for cleanliness and organize the instruments and sets. SPD staff will then place them in a specified card/area for vendor pickup ... The Operating Room ... 8 The Circulating RN ... Confirm, prior to the start of the procedure that the loaner instruments have been processed at [Facilities Group Name affiliated with (three) separately certified hospitals] ...” During an interview on 2/6/24 at 1:30 PM at H 1 with (Medical Director Pharmacy and Infection Control for [Name Healthcare System] (MDIC) and Director of Accreditation and Licensing (DAL) as scribe (wrote (for facility) questions asked and answers given during interview), the MDIC stated, he had oversight for (Healthcare System’s Name). He stated, the contractor would come in (on scheduled procedures dates) with (rectal) probe attached to the machine and told (facility) equipment was ready to go. MDIC stated, the rectal probe disinfection issue was discovered when (date not mentioned) a hospital that was part of the Healthcare System wanted to own/buy the equipment. A representative (name not mentioned) from (Contractor Name) came in and asked “why are you not doing high-level disinfection (HLD, a cleaning process which achieves elimination of all microorganisms in or on medical device, except for small number of bacterial spores)?” (Contractor Name) was not doing leak testing. MDIC stated, (Contractor Name) did not have a policy on disinfection. A new representative inquired why was HLD not being done. (Healthcare System Name) received (date not given) the report from a (Healthcare System Name) staff (identifier not mentioned). The MDIC further stated, “As soon as we learned, we stopped using (rectal probe). We set up the process- analyzed, identified the system gap related to the (Contractor Name) and set up a process, collected data, who was using the probes, the type of probes used. We developed a standard work for the specific probes ...” The MDIC stated, 450 patients from the whole Healthcare System were affected. The problem was presented to Biomed (biomedical department ensures medical devices and equipment are in good repair, functions effectively and are efficient.) as a whole package- machine (rectal probe connected into ultrasound system); went to Biomed as a piece of equipment, looked at it as a single package. They (Biomed) thought it (rectal probe) was no different than an external equipment, slipped under the radar because of the way the company presented it. MDIC stated, expectation was if it goes in the orifices, it needs HLD. We missed it - the need for HLD (information on duration not done not mentioned) for the rectal probes. During a review of facility’s document with 8 (eight) pages, not titled, printed 2/50 (sic)/2024, document indicated columned lists information with [ Facilities Group Name affiliated with (three) separately certified hospitals], Patient (s) Name, Medical Record Number, Date of Birth, Date of Procedure, Procedure, Address, Medical Doctor’s Name(s), Page 8 indicated Total: 179 (total number of patients affected with rectal probe disinfection issue) ...” During an interview on 2/7/24 at 4 PM, at H 1, with DAL, DAL stated it was she who notified SA regarding the rectal probe disinfection issue. The 8 (eight) Pages document was the list of patients affected with rectal probe disinfection issue for [Facilities Group Name affiliated with (three) separately certified hospitals], Hospital (H)1, H 2, and H 3. Also, individuals(s) with authority and responsibilities for the conduct of the hospital and patient care (governing body) were the same for [(Healthcare System’s Name), [Facilities Group Name affiliated with (three) separately certified hospitals] H 1, H 2, and H 3; and all facility policies and procedures for H 1, H 2, and H 3 were (Healthcare System’s Name), [Facilities Group Name affiliated with (three) separately certified hospitals] policies and procedures. During a video call interview on 2/9/24 at 10:14 AM, at H 1 surveyors reviewed facility contract agreement packet titled, “Contract #SC14548, [(Name) Healthcare System], Sixth Amendment”, Renewed 4/30/2023, with Senior Director (Strategic Sourcing) (SDSS) for [(Name) Healthcare System] and Strategic Sourcing Manager for Contracting (SSMC), DAL was scribe. SDSS confirmed she signed contract agreement between “customer” [(Name) Healthcare System] and “contractor” [(Contractor Name) contractor who provided rectal probes)]. SDSS verified initial contract date was April 18, 2016, and expiring on 4/30/24. SSMC stated contract had auto renewal option. SDSS stated, for [(Name) Healthcare System], [Facilities Group Name in (Name) Area affiliated with (three) separately certified acute care hospitals] who use the same services, we [(Name) Healthcare System] employees responsible for contract agreement(s)] try to consolidate vendors [contractor(s)]. This one (contract agreement) started before I started with [(Name) Healthcare System]. SDSS confirmed contract applied to all [(Name) Healthcare System], [Facilities Group Name in (Name) Area affiliated with (three) separately certified acute care hospitals]. Surveyors reviewed with SDSS and SSMC contract agreement, “Page 1 of 20 ... AGREEMENT, I. SERVICES COVERED, 1. Services/ Products/Scope of Work” (Contractor) responsibilities and services to be provided for rented rectal probes (models not indicated), to (Healthcare System’s Name), ([Facilities Group Name] affiliated with (three) separately certified acute care hospitals in (Name) area] were not indicated/specified. SDSS stated, I think this contract has a gap. There should be additional amendment. SSMC stated, I’m not seeing amendments, looking for updates in the contracts, changes in the services ... Sixth amendment: current executed version, did not have vendor responsibilities, (in exhibit E, that should have been included in the current contract). SDSS stated, Basic HLD (high level disinfection) for scopes (general policy) - that policy requires that we perform HLD for items from vendors, checked by biomed. IC (Infection Control) department should be involved but this device (rented rectal probe) was not on the list of things that need HLD. It is the hospital’s responsibility to apply the IFU (instructions for use). It’s the directors in each department that is responsible for following the MIFU (manufacturer’s instructions for use). During an interview on 2/9/24 at 2:06 PM, at H 1, with Chief Operating Officer (COO) and DAL as scribe, COO stated, he was one of a group of individuals who had oversight (authority and responsibilities (governing body) for the conduct of the hospital and patient care) for [(Name) Healthcare System] [Facilities Group Name affiliated with (three) separately certified acute care hospitals] He confirmed each hospital had its own provider (Medicare) number. COO stated the rectal probe disinfection issue was not usual by definition - confirmed it was an unusual occurrence. The COO stated that before reporting (to CDPH), “we wanted to investigate to make sure what was happening. We had to determine whether patients were affected, which hospitals were using (the rectal probe), had to determine facts.” COO stated, with routine negotiation (of contracts) Board of Directors [(Name) Area Operating Board] were not involved in what was included in the contract. [(Name)Healthcare] “System” was responsible for contracts (agreement) with (Contractor) (effective 4/18/16, renewed 4/18/2021); but, he (COO) would have input. The COO stated, “The (Contractor) (vendor representative) is not responsible for the HLD, it’s the hospital’s job. Our policy indicates, in general, we’re supposed to do it (HLD). The HLD is our responsibility, we’re supposed to sterilize prior to use, to prevent transmission of infections. There was belief that we were doing what we were supposed to do in cleaning it (rectal probe), and equipment used for patients. HLD - that is our responsibility and we failed to do that.” The COO stated the directors of surgical services [DSS) - (Representatives for Quality Assurance are responsible for ensuring MIFU is followed. COO stated, regarding rectal probe disinfection issue not included in Quality Assurance Performance Improvement (QAPI) minutes for November to December 2023, January 2024 - “we have not gotten there yet, but it does not mean we did not discuss it.” During a concurrent observation and interview with the Scrub Technician (ST 2) on 2/14/24 at 8:16 a.m. in the operating room (OR), ST 2 stated the surgical procedure had just finished and he was beginning the “pre-cleaning” process for the rectal ultrasound probe used in the procedure. During the pre-cleaning process, ST 2 was observed wiping the probe with disinfecting wipes beginning at the tip of the probe moving toward the top of the probe and ending at the cord which connects to the ultrasound monitor (in a dirty to clean direction). After wiping the probe, ST 2 placed the probe into a bin and stated, “Now it needs to dry for three minutes.” ST 2 left the probe in the bin for three minutes while performing other tasks. ST 2 then stated, it had been three minutes and he covered the bin with a red bag. The bin containing the probe was then sent in the elevator to the Sterile Processing Department (SPD an area within the hospital in which medical/surgical supplies and equipment, are cleaned, prepared, processed, stored, and issued for patient care). During a concurrent observation and interview with the Sterile Processing Technician (SPT 4) on 2/14/24 at 8:26 a.m. in the SPD, SPT 4 stated, he had just received the probe from the OR and was beginning the High-Level Disinfection process (a cleaning process which achieves elimination of all microorganisms in or on a medical device, except for small numbers of spores). SPT 4 stated a leak test (a process required to protect patients from infection that could result from leaks in the device and also protects the device from damage) was required for the probe to ensure there were no small holes in the probe. SPT 1 placed the leak tester on the end of the probe cord and pumped the pressure to a reading of 150 mm (millimeter of mercury- a measurement used to record pressure). Immediately after obtaining a pressure reading of 150 mm, SPT 1 stated, “It’s holding strong, so it passed the leak test.” SPT 4 did not monitor the pressure reading during the leak test for a specific amount of time. During a review of the manufacturer’s IFU for the disinfecting wipes the facility used on the rectal ultrasound probe, the IFU indicated, “This product is not to be used as a terminal sterilant/HLD on any surface or instrument that is introduced directly into the human body ... or contacts intact mucus membranes ... this product may be used to preclean medical devices prior to HLD.” During an interview on 2/14/24 at 10:10 a.m. with the Infection Prevention Manager (IPM), IPM stated the facility was part of a [hospital system] who had multiple hospitals in the state; in addition, the facility was part of a small group of three hospitals which shared a governing body and had a shared Infection Prevention Department. IPM stated she had oversight of three hospitals and there was a dedicated Infection Preventionist (IP) at each hospital. IPM further stated the three hospitals shared another IP who had oversight of surgical services for all three hospitals. IPM stated, in November 2023, she received a call from the Clinical Process Improvement Consultant (CPIC) for the facility’s hospital system regarding the facility’s use of rectal ultrasound probes. IPM stated, she was unaware if the facility used the rectal ultrasound probes, and she sent out an email to the Surgical Services Department at the facility to inquire about the use of the probes. IPM stated the hospital used the Spaulding Classification System (a nationally recognized infection control standard which is used to define the minimum level of disinfection required for a medical device) to determine how medical devices should be cleaned. IPM stated rectal ultrasound probes required High-level Disinfection (HLD- a cleaning process which achieves elimination of all microorganisms in or on a medical device, except for small numbers of bacterial spores) because the probe came in contact with mucous membranes (soft lining of body cavities and canals that lead to the outside of the body). IPM stated, she received an email response from the Surgical Services Manager who confirmed the rectal ultrasound probes were used in the operating room (OR) and reported the cleaning and disinfecting procedure did not include HLD. IPM stated she was unaware of the facility’s process for cleaning and disinfecting the probes until that date. IPM stated, at that time, the facility was instructed to stop the use of the probes as the cleaning and disinfection process was inadequate. During an interview on 2/14/24 at 1:10 p.m. with the Surgical Services Manager (MSS 3), MSS 3 stated the facility performed surgical procedures using a rectal ultrasound probe. MSS 3 stated the facility contracted with a vendor who brought the rectal ultrasound probe to the Operating Room (OR) to be used for a procedure and OR staff cleaned the probe with a disinfecting wipe, covered the probe with a plastic sheath, and used it during the procedure. MSS stated, after the procedure, OR staff removed the plastic sheath, cleaned the probe with a disinfecting wipe, and gave the probe back to the vendor. MSS 3 confirmed the facility used the Spaulding Classification System (a nationally recognized infection control standard which is used to define the minimum level of disinfection required for a medical device) to determine how medical devices should be cleaned. MSS 3 confirmed, according to Spaulding Classification, rectal ultrasound probes come in contact with mucus membranes (soft lining of body cavities and canals that lead to the outside of the body) and required High-Level Disinfection at a minimum. MSS 3 stated she had worked at the facility for approximately four years and stated, “This is the way it was always done so I didn’t question it.” MSS 3 stated the facility was instructed to stop the use of the probes until further notice. During an interview on 2/14/24 at 2:42 p.m. with the Infection Prevention Registered Nurse (IP 1), IP 1 stated staff were expected to follow manufacturer’s IFU for all medical devices, for cleaning and disinfecting products. IP 1 further stated, it was his understanding that the rectal ultrasound probe manufacturer IFU allowed for low- level disinfection (a process that kills bacteria and some viruses on items that only come in contact with intact skin). IP 1 confirmed rectal ultrasound probes come in contact with mucus membranes and should be, at minimum, HLD according to the facility’s policy. During an interview on 2/15/24 at 9:30 a.m. with the Clinical Process Improvement Consultant (CPIC) for the facility’s hospital system, CPIC stated she worked for [hospital system name] which owned multiple hospitals in the state and the facility was a system hospital. CPIC stated, in November 2023, she received a concern from a staff member at a different hospital related to cleaning and disinfecting rectal ultrasound probes, so she reached out to all system hospitals to determine what their current process was. CPIC stated it was determined the facility was renting the rectal ultrasound probes from [vendor]. CPIC further stated, it was determined the facility was not cleaning and disinfecting the rectal ultrasound probes adequately. CPIC stated rectal ultrasound probes were considered semi-critical devices (any device that comes in contact with a mucus membrane) and required High Level Disinfection (HLD- a cleaning process which achieves elimination of all microorganisms in or on a medical device, except for small numbers of bacterial spores), at a minimum. CPIC confirmed the facility was not performing HLD on these devices. CPIC stated the facility was instructed to stop using the rectal ultrasound probes until an investigation was conducted. During a review of the (MIFU) for the rectal ultrasound probe, titled “[Manufacturer] Care and Cleaning”, dated 2022, indicated, “Page 29, Levels of Reprocessing The level of reprocessing depends on the type of equipment and its use. The CDC (the nation’s leading science-based, data-driven, service organization that protects the public’s health) ... classify medical devices according to their use. For each classification, they specify the level of disinfection/sterilization processing that is required before use ... Device Classification: Semi-Critical; Use: Device contacts mucus membranes (for example, endocavity (anus (the external body orifice (opening) at the end of the digestive tract (bowel-intestine), the opposite end from the mouth); rectum (is at the end of your colon (large intestine) and on the other side of your anal canal); vagina( the elastic, muscular reproductive organ of the female genital tract); Required Processing: Immediate cleaning and high-level disinfection or sterilization ...” During a review of the facility’s policy and procedure (P&P) titled, “Infection Control Strategies for Handling Disinfection and Maintenance of Flexible Scopes, Rigid Endoscopes, Probes, Instruments,” dated 6/22/23, the P&P indicated, “The Spaulding Classification is used to define the minimum level of disinfection or sterilization required ... This classification system is based on the type of instrument used as well as the type of tissue exposed ... Semi-critical items= HLD required: devices contact mucous membranes or non-intact skin ... Endo cavity probes [a probe inserted into the human body] are heat sensitive, reusable Semi-critical devices that require HLD.” During a concurrent interview and record review on 2/15/24 at 3:45 p.m. with the Director of Accreditation and Licensing (DAL), the “List of [hospital] Patient Notification” was reviewed. DAL stated the facility identified a list of patients who had procedures using the rectal ultrasound probe and may have been affected by the failure to HLD the probes. DAL stated, the facility sent notification letters to all patients on the list. The list included a total of thirty-three patients. During a review of the facility (Healthcare System’s Name), [Facilities Group Name affiliated with (three) separately certified hospitals], document titled, “Infection Prevention and Control Plan,” dated 3/16/23, indicated, “Geographical Location, [Facilities Group Name affiliated with (three) separately certified hospitals], is a group of (Name ) area acute care facilities with 585 beds ... [Facilities Group Name affiliated with (three) separately certified hospitals], provides tertiary (high level of specialized care) care services for ... California ... Authority and Responsibilities, The Governing Body and the [hospital] Infection Prevention and Control Committee members have the overall authority and responsibility for the Infection Prevention and Control Program...””

    Rule A0084. Standard-level. From a complaint.

  • Contracted Services

    The inspectors’ words, 3,570 words

    “CONTRACTED SERVICES CFR(s): 482.12(e)(2) The hospital must maintain a list of all contracted services, including the scope and nature of the services provided. This Standard is not met as evidenced by: 28225 Based on observation, interview and record review, the Governing Body for (Healthcare System’s Name), for [Facilities Group Name affiliated with (three) separately certified hospitals], Hospital (H) 2 failed to ensure contractor responsibilities and services to be provided with rented rectal probes were specified on the Contract agreement. This failure resulted in the potential exposure for 33 patients.at risk to be exposed to infectious diseases such as hepatitis (inflammation of the liver caused by infection) and/or human immunodeficiency virus (HIV- a virus that attacks the immune system). Findings: During a group interview on 2/5/24, at 10:07 AM, at (Hospital) H 1 with the Director of Accreditation and Licensing (DAL), Manager of Accreditation and Licensing (MAL), Director of Quality, Patient Safety, and Infection Control (DQI), Chief Nursing Executive (CNE), and Infection Control Manager (ICM), the DQI stated, in November 2023 the facility received an email notification from (Healthcare System’s Name) there may be potential patients at risk regarding infection control issues with the use of the ultrasound rectal probes. The DQI stated, the email contained instruction to reach out to the local managers (of hospitals operating under (Healthcare System’s Name), [Facilities Group Name affiliated with (three) separately certified hospitals] to evaluate the process. The DQI stated, the facility’s use of the ultrasound rectal probe dated back ten years and it was a rented equipment. The DQI further stated, that before the hospital was notified of the rectal probe disinfection issue, the staff performed low level disinfection (LLD, a process that kills bacteria and some viruses on items that only come in contact with intact skin) prior to using the probe and the re-processing (cleaning, disinfection, and sterilization of reusable medical equipment/devices) of the ultrasound rectal probe did not include high-level disinfection (HLD, a cleaning process which achieves elimination of all microorganisms in or on medical device, except for small number of bacterial spores). The DQI further stated, the facility suspended the use of the rectal probe, identified the patients at risk, sent notification letters to patients at risk, and notified local and state agencies. The use of the rectal probe was re-launched sometime in December 2023. During a review of facility’s document titled, “(Contractor’s Name) Rectal Probe Review Timeline”, received 2/5/24 indicated, “11/13/2023, 9:55 AA, Systems (Healthcare System) e-mail inform and action needed - HLD rectal probes, sites need to take immediate action to stop the use of inadequate disinfected devices on patients and implement an effective HDL process. 1. Identify all your usable devices that contact mucous membranes or sterile body sites., 2. Stop use of all devices identified in item one with inadequate HDL., 3. Investigate the current process and ensure appropriate HDL sterilization processes in place for MIFU., 4. Perform and document a risk assessment., 5. Resume use of these devices only when an appropriate disinfection* process is in place ... Please note : We are in the process validated facts and may have additional guidance as we learn more information we have reached out the company and are awaiting their response ... 11/14-15/2023 ... IC (Infection Control) fact finding and investigation + (plus) suspend use of probes ... 11/30/2023, Initiate Training, Education and Communication to Staff + local audits ... 12/11 and 15/2023, Relaunch of (Contractor’s Name) (rectal) Probe at H 1, H 2, H 3 (12/15) ... 1/8/2024, [Facilities Group Name affiliated with (three) separately certified hospitals] Notify CDPH ... 2/5/24, To date ... 179 [ Facilities Group Name affiliated with (three) separately certified hospitals] patients were notified ... “ Review of the facility letter sent to the State Agency [SA, California Department of Public Health (CDPH, ensures compliance with state licensing laws and federal certification regulations)], dated 1/8/24 indicated, “Notice of rectal probe disinfection process issue... we have newly learned that the disinfection process performed on this equipment did not meet the required high level disinfection (“HDL”) process for reusable rectal probes ... Immediate actions taken: We suspended the use of all reusable rectal probes ... 2. We ensured that an appropriate level of disinfection or sterilization is in place ... Next steps: 1. Patients identified as having a potential exposure are being notified ... 2. We are offering these patients free Hepatitis C (liver infection caused by the hepatitis C virus), Hepatitis B (inflammation of the liver by the hepatitis B virus) and HIV (HIV- a virus that attacks the immune system) tests.” During an observation and interview on 2/6/24 at 8:49 AM, at H 1, with VR, in the Operating Room (OR, sterile location where surgical procedures were performed) suite, VR stated, rectal probe model 8848 was used during the procedure (2/6/24). VR stated, whenever a rectal probe was needed for a procedure, he or another VR brought the rectal probe from the contractor facility to the hospital [(one of (three) separately certified hospitals) where it was scheduled to be used. VR stated, before the hospital was notified of the rectal probe disinfection issue, after the procedure he (VR) wiped the rectal probe thoroughly with the disinfectant wipe, put it inside the rectal probe container, and brought it back with him to the contractor facility. VR stated, he’s brought the rectal probe from the contractor facility to the hospital for the procedures since “a few years”. VR said he learned (was trained) how to disinfect the rectal probe “on the job”. VR stated, he had no documentation (from contractor) to verify competency (ability to do something successfully, effectively, or efficiently) with disinfection/decontamination of the rectal probe. VR further stated, after the rectal probe was brought back to the contractor facility, he did not know if further decontamination of the rectal probe was done at the contractor facility or before the rectal probe was reused for another procedure. During an interview on 2/6/24 at 1:30 PM at H 1 with (Medical Director Pharmacy and Infection Control for [Name Healthcare System] (MDIC) and Director of Accreditation and Licensing (DAL) as scribe (wrote (for facility) questions asked and answers given during interview), the MDIC stated, he had oversight for (Healthcare System’s Name). He stated, the contractor would come in (on scheduled procedures dates) with (rectal) probe attached to the machine and told (facility) equipment was ready to go. MDIC stated, the rectal probe disinfection issue was discovered when (date not mentioned) a hospital that was part of the Healthcare System wanted to own/buy the equipment. A representative (name not mentioned) from (Contractor Name) came in and asked “why are you not doing high-level disinfection (HLD, a cleaning process which achieves elimination of all microorganisms in or on medical device, except for small number of bacterial spores)?” (Contractor Name) was not doing leak testing. MDIC stated, (Contractor Name) did not have a policy on disinfection. A new representative inquired why was HLD not being done. (Healthcare System Name) received (date not given) the report from a (Healthcare System Name) staff (identifier not mentioned). The MDIC further stated, “As soon as we learned, we stopped using (rectal probe). We set up the process- analyzed, identified the system gap related to the (Contractor Name) and set up a process, collected data, who was using the probes, the type of probes used. We developed a standard work for the specific probes ...” The MDIC stated, 450 patients from the whole Healthcare System were affected. The problem was presented to Biomed (biomedical department ensures medical devices and equipment are in good repair, functions effectively and are efficient.) as a whole package- machine (rectal probe connected into ultrasound system); went to Biomed as a piece of equipment, looked at it as a single package. They (Biomed) thought it (rectal probe) was no different than an external equipment, slipped under the radar because of the way the company presented it. MDIC stated, expectation was if it goes in the orifices, it needs HLD. We missed it - the need for HLD (information on duration not done not mentioned) for the rectal probes. During a review of facility’s document with 8 (eight) pages, not titled, printed 2/50 (sic)/2024, document indicated columned lists information with [ Facilities Group Name affiliated with (three) separately certified hospitals], Patient (s) Name, Medical Record Number, Date of Birth, Date of Procedure, Procedure, Address, Medical Doctor’s Name(s), Page 8 indicated Total: 179 (total number of patients affected with rectal probe disinfection issue) ...” During an interview on 2/7/24 at 4 PM, at H 1, with DAL, DAL stated it was she who notified SA regarding the rectal probe disinfection issue. The 8 (eight) Pages document was the list of patients affected with rectal probe disinfection issue for [Facilities Group Name affiliated with (three) separately certified hospitals], Hospital (H)1, H 2, and H 3. Also, individuals(s) with authority and responsibilities for the conduct of the hospital and patient care (governing body) were the same for [(Healthcare System’s Name), [Facilities Group Name affiliated with (three) separately certified hospitals] H 1, H 2, and H 3; and all facility policies and procedures for H 1, H 2, and H 3 were (Healthcare System’s Name), [Facilities Group Name affiliated with (three) separately certified hospitals] policies and procedures. During a video call interview on 2/9/24 at 10:14 AM, at H 1 surveyors reviewed facility contract agreement packet titled, “Contract #SC14548, [(Name) Healthcare System], Sixth Amendment”, Renewed 4/30/2023, with Senior Director (Strategic Sourcing) (SDSS) for [(Name) Healthcare System] and Strategic Sourcing Manager for Contracting (SSMC), DAL was scribe. SDSS confirmed she signed contract agreement between “customer” [(Name) Healthcare System] and “contractor” [(Contractor Name) contractor who provided rectal probes)]. SDSS verified initial contract date was April 18, 2016, and expiring on 4/30/24. SSMC stated contract had auto renewal option. SDSS stated, for [(Name) Healthcare System], [Facilities Group Name in (Name) Area affiliated with (three) separately certified acute care hospitals] who use the same services, we [(Name) Healthcare System] employees responsible for contract agreement(s)] try to consolidate vendors [contractor(s)]. This one (contract agreement) started before I started with [(Name) Healthcare System]. SDSS confirmed contract applied to all [(Name) Healthcare System], [Facilities Group Name in (Name) Area affiliated with (three) separately certified acute care hospitals]. Surveyors reviewed with SDSS and SSMC contract agreement, “Page 1 of 20 ... AGREEMENT, I. SERVICES COVERED, 1. Services/ Products/Scope of Work” (Contractor) responsibilities and services to be provided for rented rectal probes (models not indicated), to (Healthcare System’s Name), ([Facilities Group Name] affiliated with (three) separately certified acute care hospitals in (Name) area] were not indicated/specified. SDSS stated, I think this contract has a gap. There should be additional amendment. SSMC stated, I’m not seeing amendments, looking for updates in the contracts, changes in the services ... Sixth amendment: current executed version, did not have vendor responsibilities, (in exhibit E, that should have been included in the current contract). SDSS stated, Basic HLD (high level disinfection) for scopes (general policy) - that policy requires that we perform HLD for items from vendors, checked by biomed. IC (Infection Control) department should be involved but this device (rented rectal probe) was not on the list of things that need HLD. It is the hospital’s responsibility to apply the IFU (instructions for use). It’s the directors in each department that is responsible for following the MIFU (manufacturer’s instructions for use). During an interview on 2/9/24 at 2:06 PM, at H 1, with Chief Operating Officer (COO) and DAL as scribe, COO stated, he was one of a group of individuals who had oversight (authority and responsibilities (governing body) for the conduct of the hospital and patient care) for [(Name) Healthcare System] [Facilities Group Name affiliated with (three) separately certified acute care hospitals] He confirmed each hospital had its own provider (Medicare) number. COO stated the rectal probe disinfection issue was not usual by definition - confirmed it was an unusual occurrence. The COO stated that before reporting (to CDPH), “we wanted to investigate to make sure what was happening. We had to determine whether patients were affected, which hospitals were using (the rectal probe), had to determine facts.” COO stated, with routine negotiation (of contracts) Board of Directors [(Name) Area Operating Board] were not involved in what was included in the contract. [(Name)Healthcare] “System” was responsible for contracts (agreement) with (Contractor) (effective 4/18/16, renewed 4/18/2021); but, he (COO) would have input. The COO stated, “The (Contractor) (vendor representative) is not responsible for the HLD, it’s the hospital’s job. Our policy indicates, in general, we’re supposed to do it (HLD). The HLD is our responsibility, we’re supposed to sterilize prior to use, to prevent transmission of infections. There was belief that we were doing what we were supposed to do in cleaning it (rectal probe), and equipment used for patients. HLD - that is our responsibility and we failed to do that.” The COO stated the directors of surgical services [DSS) - (Representatives for Quality Assurance are responsible for ensuring MIFU is followed. COO stated, regarding rectal probe disinfection issue not included in Quality Assurance Performance Improvement (QAPI) minutes for November to December 2023, January 2024 - “we have not gotten there yet, but it does not mean we did not discuss it.” During a concurrent observation and interview with the Scrub Technician (ST 2) on 2/14/24 at 8:16 a.m. in the operating room (OR), ST 2 stated the surgical procedure had just finished and he was beginning the “pre-cleaning” process for the rectal ultrasound probe used in the procedure. During the pre-cleaning process, ST 2 was observed wiping the probe with disinfecting wipes beginning at the tip of the probe moving toward the top of the probe and ending at the cord which connects to the ultrasound monitor (in a dirty to clean direction). After wiping the probe, ST 2 placed the probe into a bin and stated, “Now it needs to dry for three minutes.” ST 2 left the probe in the bin for three minutes while performing other tasks. ST 2 then stated, it had been three minutes and he covered the bin with a red bag. The bin containing the probe was then sent in the elevator to the Sterile Processing Department (SPD). During a concurrent observation and interview with the Sterile Processing Technician (SPT 4) on 2/14/24 at 8:26 a.m. in the Sterile Processing Department (SPD an area within the hospital in which medical/surgical supplies and equipment, are cleaned, prepared, processed, stored, and issued for patient care), SPT 4 stated, he had just received the probe from the OR and was beginning the High-Level Disinfection process (a cleaning process which achieves elimination of all microorganisms in or on a medical device, except for small numbers of spores). SPT 4 stated a leak test (a process required to protect patients from infection that could result from leaks in the device and also protects the device from damage) was required for the probe to ensure there were no small holes in the probe. SPT 1 placed the leak tester on the end of the probe cord and pumped the pressure to a reading of 150 mm (millimeter of mercury- a measurement used to record pressure). Immediately after obtaining a pressure reading of 150 mm, SPT 1 stated, “It’s holding strong, so it passed the leak test.” SPT 4 did not monitor the pressure reading during the leak test for a specific amount of time. During an interview on 2/14/24 at 10:10 a.m. with the Infection Prevention Manager (IPM), IPM stated the facility was part of a [hospital system] who had multiple hospitals in the state; in addition, the facility was part of a small group of three hospitals which shared a governing body and had a shared Infection Prevention Department. IPM stated she had oversight of three hospitals and there was a dedicated Infection Preventionist (IP) at each hospital. IPM further stated the three hospitals shared another IP who had oversight of surgical services for all three hospitals. IPM stated, in November 2023, she received a call from the Clinical Process Improvement Consultant (CPIC) for the facility’s hospital system regarding the facility’s use of rectal ultrasound probes. IPM stated, she was unaware if the facility used the rectal ultrasound probes, and she sent out an email to the Surgical Services Department at the facility to inquire about the use of the probes. IPM stated the hospital used the Spaulding Classification System (a nationally recognized infection control standard which is used to define the minimum level of disinfection required for a medical device) to determine how medical devices should be cleaned. IPM stated rectal ultrasound probes required High-level Disinfection (HLD- a cleaning process which achieves elimination of all microorganisms in or on a medical device, except for small numbers of bacterial spores) because the probe came in contact with mucous membranes (soft lining of body cavities and canals that lead to the outside of the body). IPM stated, she received an email response from the Surgical Services Manager who confirmed the rectal ultrasound probes were used in the operating room (OR) and reported the cleaning and disinfecting procedure did not include HLD. IPM stated she was unaware of the facility’s process for cleaning and disinfecting the probes until that date. IPM stated, at that time, the facility was instructed to stop the use of the probes as the cleaning and disinfection process was inadequate. During an interview on 2/14/24 at 1:10 p.m. with the Surgical Services Manager (MSS 3), MSS 3 stated the facility performed surgical procedures using a rectal ultrasound probe. MSS 3 stated the facility contracted with a vendor who brought the rectal ultrasound probe to the Operating Room (OR) to be used for a procedure and OR staff cleaned the probe with a disinfecting wipe, covered the probe with a plastic sheath, and used it during the procedure. MSS stated, after the procedure, OR staff removed the plastic sheath, cleaned the probe with a disinfecting wipe, and gave the probe back to the vendor. MSS 3 confirmed the facility used the Spaulding Classification System to determine how medical devices should be cleaned. MSS 3 confirmed, according to Spaulding Classification, rectal ultrasound probes come in contact with mucus membranes (soft lining of body cavities and canals that lead to the outside of the body) and required High-Level Disinfection at a minimum. MSS 3 stated she had worked at the facility for approximately four years and stated, “This is the way it was always done so I didn’t question it.” During an interview on 2/14/24 at 2:42 p.m. with the Infection Prevention Registered Nurse (IP 1), IP 1 stated the IFU for the disinfecting wipes indicated a “wet time” of three minutes which meant the device should be maintained wet with the disinfecting product for three minutes and then dried with a cloth. IP 1 stated staff were expected to follow manufacturer’s IFU for all medical devices, for cleaning and disinfecting products. IP 1 further stated, it was his understanding that the rectal ultrasound probe manufacturer IFU allowed for low- level disinfection (a process that kills bacteria and some viruses on items that only come in contact with intact skin). IP 1 confirmed rectal ultrasound probes come in contact with mucus membranes and should be, at minimum, HLD according to the facility’s policy. During an interview on 2/15/24 at 9:30 a.m. with the Clinical Process Improvement Consultant (CPIC) for the facility’s hospital system, CPIC stated she worked for [hospital system name] which owned multiple hospitals in the state and the facility was a system hospital. CPIC stated, in November 2023, she received a concern from a staff member at a different hospital related to cleaning and disinfecting rectal ultrasound probes, so she reached out to all system hospitals to determine what their current process was. CPIC stated it was determined the facility was renting the rectal ultrasound probes from [vendor]. CPIC further stated, it was determined the facility was not cleaning and disinfecting the rectal ultrasound probes adequately. CPIC stated rectal ultrasound probes were considered semi-critical devices (any device that comes in contact with a mucus membrane) and required HLD, at a minimum. CPIC confirmed the facility was not performing HLD on these devices. CPIC stated the facility was instructed to stop using the rectal ultrasound probes until an investigation was conducted. During a concurrent interview and record review on 2/15/24 at 3:45 p.m. with the Director of Accreditation and Licensing (DAL), the “List of [hospital] Patient Notification” was reviewed. DAL stated the facility identified a list of patients who had procedures using the rectal ultrasound probe and may have been affected by the failure to HLD the probes. DAL stated, the facility sent notification letters to all patients on the list. The list included a total of thirty-three patients. During a review of the facility (Healthcare System’s Name), [Facilities Group Name affiliated with (three) separately certified hospitals], document titled, “Infection Prevention and Control Plan,” dated 3/16/23, indicated, “Geographical Location, [Facilities Group Name affiliated with (three) separately certified hospitals], is a group of (Name ) area acute care facilities with 585 beds ... [Facilities Group Name affiliated with (three) separately certified hospitals], provides tertiary (high level of specialized care) care services for ... California ... Authority and Responsibilities, The Governing Body and the [hospital] Infection Prevention and Control Committee members have the overall authority and responsibility for the Infection Prevention and Control Program...””

    Rule A0085. Standard-level. From a complaint.

  • Qapi Executive Responsibilities

    The inspectors’ words, 5,793 words

    “QAPI EXECUTIVE RESPONSIBILITIES CFR(s): 482.21(e)(1), (e)(2), (e)(5) The hospital’s governing body (or organized group or individual who assumes full legal authority and responsibility for operations of the hospital), medical staff, and administrative officials are responsible and accountable for ensuring the following: 1) That an ongoing program for quality improvement and patient safety, including the reduction of medical errors, is defined, implemented, and maintained . (2) That the hospital-wide quality assessment and performance improvement efforts address priorities for improved quality of care and patient safety and that all improvement actions are evaluated. (5) That the determination of the number of distinct improvement projects is conducted annually. This Standard is not met as evidenced by: 28225 Based on observation, interview and record review, the facility failed to ensure Hospital 2 leaders maintained oversight of Department Services operational policies and procedures for Infection Control, Sterile Processing Department (SPD an area within the hospital in which medical/surgical supplies and equipment, are cleaned, prepared, processed, stored, and issued for patient care), Operating Room (OR, sterile location where surgical procedures were performed), and Contract Services for (Healthcare System’s Name), [Facilities Group Name affiliated with (three) separately certified hospitals], Hospital (H) 2 when: 1. Rectal ultrasound probes (probe inserted into the rectum which uses sound waves to produce images during a surgical procedure) were cleaned and disinfected according to the manufacturer’s instructions for use (IFU) and facility policy. As a result of this failure, thirty-three patients were potentially exposed to infectious diseases such as hepatitis (inflammation of the liver caused by infection) or human immunodeficiency virus (HIV- a virus that attacks the immune system). 2. Staff did not follow the facility’s Standard Work (a document with step-by-step instructions) and manufacturer’s instructions for use (IFU) when cleaning and disinfecting a rectal ultrasound probe (probe inserted into the rectum which uses sound waves to produce images during a surgical procedure), after a procedure. This failure resulted in the potential that the probe was not adequately disinfected. 3. One rusty cylinder tank of compressed air (air that is pressurized to greater than atmospheric pressure) was in Operating Room 5. This deficient practice had the potential for cross contamination (transfer of harmful bacteria from one person, object or place to another) to happen. 4. Sterile surgical instruments (tools used to perform surgery) were stored to prevent contamination when rigid instrument cases were stored on top of soft wrapped instrument packs. This failure resulted in the potential for contaminated surgical instruments. 5. Total of six (6) expired plastic containers of sterile water humidifier with expiration date of “2/8/23” were stored in the bottom of the three-tiered rack inside the Clean Room of the Post Anesthesia Care Unit (PACU, is a critical care unit and specialty that focuses on the recovery and treatment of patients immediately following surgical procedures and anesthesia). This failure resulted in the potential cross contamination (transfer of harmful bacteria from one person, object or place to another) to happen. The deficient practices resulted in the facility’s inability to provide quality healthcare in a safe environment. Findings: 1. During a group interview on 2/5/24, at 10:07 AM, at (Hospital) H 1 with the Director of Accreditation and Licensing (DAL), Manager of Accreditation and Licensing (MAL), Director of Quality, Patient Safety, and Infection Control (DQI), Chief Nursing Executive (CNE), and Infection Control Manager (ICM), the DQI stated, in November 2023 the facility received an email notification from (Healthcare System’s Name) there may be potential patients at risk regarding infection control issues with the use of the ultrasound rectal probes. The DQI stated, the email contained instruction to reach out to the local managers (of hospitals operating under (Healthcare System’s Name), [Facilities Group Name affiliated with (three) separately certified hospitals] to evaluate the process. The DQI stated, the facility’s use of the ultrasound rectal probe dated back ten years and it was a rented equipment. The DQI further stated, that before the hospital was notified of the rectal probe disinfection issue, the staff performed low level disinfection (LLD, a process that kills bacteria and some viruses on items that only come in contact with intact skin) prior to using the probe and the re-processing (cleaning, disinfection, and sterilization of reusable medical equipment/devices) of the ultrasound rectal probe did not include high-level disinfection (HLD, a cleaning process which achieves elimination of all microorganisms in or on medical device, except for small number of bacterial spores). The DQI further stated, the facility suspended the use of the rectal probe, identified the patients at risk, sent notification letters to patients at risk, and notified local and state agencies. The use of the rectal probe was re-launched sometime in December 2023. During a review of facility’s document titled, “(Contractor’s Name) Rectal Probe Review Timeline”, received 2/5/24 indicated, “11/13/2023, 9:55 AA, Systems (Healthcare System) e-mail inform and action needed - HLD rectal probes, sites need to take immediate action to stop the use of inadequate disinfected devices on patients and implement an effective HDL process. 1. Identify all your usable devices that contact mucous membranes or sterile body sites., 2. Stop use of all devices identified in item one with inadequate HDL., 3. Investigate the current process and ensure appropriate HDL sterilization processes in place for MIFU., 4. Perform and document a risk assessment., 5. Resume use of these devices only when an appropriate disinfection* process is in place ... Please note : We are in the process validated facts and may have additional guidance as we learn more information we have reached out the company and are awaiting their response ... 11/14-15/2023 ... IC (Infection Control) fact finding and investigation + (plus) suspend use of probes ... 11/30/2023, Initiate Training, Education and Communication to Staff + local audits ... 12/11 and 15/2023, Relaunch of (Contractor’s Name) (rectal) Probe at H 1, H 2, H 3 (12/15) ... 1/8/2024, [Facilities Group Name affiliated with (three) separately certified hospitals] Notify CDPH ... 2/5/24, To date ... 179 [ Facilities Group Name affiliated with (three) separately certified hospitals] patients were notified ... “ Review of the facility letter sent to the State Agency [SA, California Department of Public Health (CDPH, ensures compliance with state licensing laws and federal certification regulations)], dated 1/8/24 indicated, “Notice of rectal probe disinfection process issue... we have newly learned that the disinfection process performed on this equipment did not meet the required high level disinfection (“HDL”) process for reusable rectal probes ... Immediate actions taken: We suspended the use of all reusable rectal probes ... 2. We ensured that an appropriate level of disinfection or sterilization is in place ... Next steps: 1. Patients identified as having a potential exposure are being notified ... 2. We are offering these patients free Hepatitis C (liver infection caused by the hepatitis C virus), Hepatitis B (inflammation of the liver by the hepatitis B virus) and HIV (HIV- a virus that attacks the immune system) tests.” During an observation and interview on 2/6/24 at 8:49 AM, at H 1, with VR, in the Operating Room (OR, sterile location where surgical procedures were performed) suite, VR stated, rectal probe model 8848 was used during the procedure (2/6/24). VR stated, whenever a rectal probe was needed for a procedure, he or another VR brought the rectal probe from the contractor facility to the hospital [(one of (three) separately certified hospitals) where it was scheduled to be used. VR stated, before the hospital was notified of the rectal probe disinfection issue, after the procedure he (VR) wiped the rectal probe thoroughly with the disinfectant wipe, put it inside the rectal probe container, and brought it back with him to the contractor facility. VR stated, he’s brought the rectal probe from the contractor facility to the hospital for the procedures since “a few years”. VR said he learned (was trained) how to disinfect the rectal probe “on the job”. VR stated, he had no documentation (from contractor) to verify competency (ability to do something successfully, effectively, or efficiently) with disinfection/decontamination of the rectal probe. VR further stated, after the rectal probe was brought back to the contractor facility, he did not know if further decontamination of the rectal probe was done at the contractor facility or before the rectal probe was reused for another procedure. Review of the facility,(Healthcare System’s Name), [Facilities Group Name affiliated with (three) separately certified hospitals], Policy and Procedures (P&P) titled, “Vendors and Sales Representatives, Special Instruments/Equipment /Supplies Guidelines in the Surgical Services Department”, revised 6/16/22 indicated, “Purpose to outline responsibilities and provide guidelines for vendor activities involving the Surgical Services department ... Scheduling and Approvals ... [Facilities Group Name affiliated with (three) separately certified hospitals] Surgical Services arranging ... 1 ... b. vendors are notified in a timely manner to allow for instrument and supplies to be prepared for the case ... 3 .... e. Manager/Supervisor/Service Leader or designee will arrange for staff education with the vendor prior to using new or unfamiliar instruments or equipment... f. Equipment or instruments may not be used during a procedure without appropriate education and or support for staff ... Sterile Processing Departments, 1 ... vendors must check in at SPD prior to entry. 2. The instrument/implant company (contractor) is responsible for delivery and pickup of instruments and implants ... 5. Pre-Procedure sets will arrive at least 24-48 hours ... a. Instruments/implant sets must be inspected, cleaned, and decontaminated, and sterilized by [Facilities Group Name affiliated with (three) separately certified hospitals] staff prior to use ... Post Procedure, 1. SPD staff will process sets through the washer/decontaminator or hand wash, if needed. Inspect for cleanliness and organize the instruments and sets. SPD staff will then place them in a specified card/area for vendor pickup ... The Operating Room ... 8 The Circulating RN ... Confirm, prior to the start of the procedure that the loaner instruments have been processed at [Facilities Group Name affiliated with (three) separately certified hospitals] ...” During a review of ( Manufacturer’s Name), titled, “Product Data Sheet, 8848 Endo Cavity Biplane Transducer”, dated July 2019, indicated, “The 8848 (Model) Endo Cavity Biplane Transducer [used to visualize (see) structures from inside body] design for use with the flex focus 1202 ultrasound system ... ideal for precise volume studies and guiding process and guiding prostate therapy ideal also for imaging the anterior and posterior compartments of the pelvic floor ... biplane imaging gives greater confidence in guiding therapy for a better orientation during needle placement expanded, sector allows complete visualization of the prostate ... perform quick reliable puncture and biopsy procedures with reusable needle guide ... unique fully immersible (capable of totally submerged in water without damage) transducer for easy sterilization ( a process that destroys or eliminates all forms of microbial life by physical or chemical methods) ... Reprocessing (a multistep process that includes cleaning, inspection, assembly, functional testing, disinfection, packaging, labeling, sterilization, and storage) ...Complete details and procedures can be found in Care and Cleaning ... Follow manufacturer’s instructions for use (MIFU) ...” During a review of the (MIFU) for the rectal ultrasound probe, titled “[Manufacturer] Care and Cleaning”, dated 2022, indicated, “Page 29, Levels of Reprocessing The level of reprocessing depends on the type of equipment and its use. The CDC (the nation’s leading science-based, data-driven, service organization that protects the public’s health) ... classify medical devices according to their use. For each classification, they specify the level of disinfection/sterilization processing that is required before use ... Device Classification: Semi-Critical; Use: Device contacts mucus membranes (for example, endocavity (anus (the external body orifice (opening) at the end of the digestive tract (bowel-intestine), the opposite end from the mouth); rectum (is at the end of your colon (large intestine) and on the other side of your anal canal); vagina( the elastic, muscular reproductive organ of the female genital tract); Required Processing: Immediate cleaning and high-level disinfection or sterilization ...” During an interview on 2/6/24 at 1:30 PM at H 1 with (Medical Director Pharmacy and Infection Control for [Name Healthcare System] (MDIC) and Director of Accreditation and Licensing (DAL) as scribe (wrote (for facility) questions asked and answers given during interview), the MDIC stated, he had oversight for (Healthcare System’s Name). He stated, the contractor would come in (on scheduled procedures dates) with (rectal) probe attached to the machine and told (facility) equipment was ready to go. MDIC stated, the rectal probe disinfection issue was discovered when (date not mentioned) a hospital that was part of the Healthcare System wanted to own/buy the equipment. A representative (name not mentioned) from (Contractor Name) came in and asked “why are you not doing high-level disinfection (HLD, a cleaning process which achieves elimination of all microorganisms in or on medical device, except for small number of bacterial spores)?” (Contractor Name) was not doing leak testing. MDIC stated, (Contractor Name) did not have a policy on disinfection. A new representative inquired why was HLD not being done. (Healthcare System Name) received (date not given) the report from a (Healthcare System Name) staff (identifier not mentioned). The MDIC further stated, “As soon as we learned, we stopped using (rectal probe). We set up the process- analyzed, identified the system gap related to the (Contractor Name) and set up a process, collected data, who was using the probes, the type of probes used. We developed a standard work for the specific probes ...” The MDIC stated, 450 patients from the whole Healthcare System were affected. The problem was presented to Biomed (biomedical department ensures medical devices and equipment are in good repair, functions effectively and are efficient.) as a whole package- machine (rectal probe connected into ultrasound system); went to Biomed as a piece of equipment, looked at it as a single package. They (Biomed) thought it (rectal probe) was no different than an external equipment, slipped under the radar because of the way the company presented it. MDIC stated, expectation was if it goes in the orifices, it needs HLD. We missed it - the need for HLD (information on duration not done not mentioned) for the rectal probes. During a review of facility’s document with 8 (eight) pages, not titled, printed 2/50 (sic)/2024, document indicated columned lists information with [ Facilities Group Name affiliated with (three) separately certified hospitals], Patient (s) Name, Medical Record Number, Date of Birth, Date of Procedure, Procedure, Address, Medical Doctor’s Name(s), (Page 8 indicated Total: 179 (total number of patients affected with rectal probe disinfection issue) ...” During an interview on 2/7/24 at 4 PM, at H 1, with DAL, DAL stated it was she who notified SA regarding the rectal probe disinfection issue. The 8 (eight) Pages document was the list of patients affected with rectal probe disinfection issue for [Facilities Group Name affiliated with (three) separately certified hospitals], Hospital (H)1, H 2, and H 3. Also, individuals(s) with authority and responsibilities for the conduct of the hospital and patient care (governing body) were the same for [(Healthcare System’s Name), [Facilities Group Name affiliated with (three) separately certified hospitals] H 1, H 2, and H 3; and all facility policies and procedures for H 1, H 2, and H 3 were (Healthcare System’s Name), [Facilities Group Name affiliated with (three) separately certified hospitals] policies and procedures. During a video call interview on 2/9/24 at 10:14 AM, at H 1 surveyors reviewed facility contract agreement packet titled, “Contract #SC14548, [(Name) Healthcare System], Sixth Amendment”, Renewed 4/30/2023, with Senior Director (Strategic Sourcing) (SDSS) for [(Name) Healthcare System] and Strategic Sourcing Manager for Contracting (SSMC), DAL was scribe. SDSS confirmed she signed contract agreement between “customer” [(Name) Healthcare System] and “contractor” [(Contractor Name) contractor who provided rectal probes)]. SDSS verified initial contract date was April 18, 2016, and expiring on 4/30/24. SSMC stated contract had auto renewal option. SDSS stated, for [(Name) Healthcare System], [Facilities Group Name in (Name) Area affiliated with (three) separately certified acute care hospitals] who use the same services, we [(Name) Healthcare System] employees responsible for contract agreement(s)] try to consolidate vendors [contractor(s)]. This one (contract agreement) started before I started with [(Name) Healthcare System]. SDSS confirmed contract applied to all [(Name) Healthcare System], [Facilities Group Name in (Name) Area affiliated with (three) separately certified acute care hospitals]. Surveyors reviewed with SDSS and SSMC contract agreement, “Page 1 of 20 ... AGREEMENT, I. SERVICES COVERED, 1. Services/ Products/Scope of Work” (Contractor) responsibilities and services to be provided for rented rectal probes (models not indicated), to (Healthcare System’s Name), ([Facilities Group Name] affiliated with (three) separately certified acute care hospitals in (Name) area] were not indicated/specified. SDSS stated, I think this contract has a gap. There should be additional amendment. SSMC stated, I’m not seeing amendments, looking for updates in the contracts, changes in the services ... Sixth amendment: current executed version, did not have vendor responsibilities, (in exhibit E, that should have been included in the current contract). SDSS stated, Basic HLD (high level disinfection) for scopes (general policy) - that policy requires that we perform HLD for items from vendors, checked by biomed. IC (Infection Control) department should be involved but this device (rented rectal probe) was not on the list of things that need HLD. It is the hospital’s responsibility to apply the IFU (instructions for use). It’s the directors in each department that is responsible for following the MIFU (manufacturer’s instructions for use). During an interview on 2/9/24 at 2:06 PM, at H 1, with Chief Operating Officer (COO) and DAL as scribe, COO stated, he was one of a group of individuals who had oversight (authority and responsibilities (governing body) for the conduct of the hospital and patient care) for [(Name) Healthcare System] [Facilities Group Name affiliated with (three) separately certified acute care hospitals] He confirmed each hospital had its own provider (Medicare) number. COO stated the rectal probe disinfection issue was not usual by definition - confirmed it was an unusual occurrence. The COO stated that before reporting (to CDPH), “we wanted to investigate to make sure what was happening. We had to determine whether patients were affected, which hospitals were using (the rectal probe), had to determine facts.” COO stated, with routine negotiation (of contracts) Board of Directors [(Name) Area Operating Board] were not involved in what was included in the contract. [(Name)Healthcare] “System” was responsible for contracts (agreement) with (Contractor) (effective 4/18/16, renewed 4/18/2021); but, he (COO) would have input. The COO stated, “The (Contractor) (vendor representative) is not responsible for the HLD, it’s the hospital’s job. Our policy indicates, in general, we’re supposed to do it (HLD). The HLD is our responsibility, we’re supposed to sterilize prior to use, to prevent transmission of infections. There was belief that we were doing what we were supposed to do in cleaning it (rectal probe), and equipment used for patients. HLD - that is our responsibility and we failed to do that.” The COO stated the directors of surgical services [DSS) - (Representatives for Quality Assurance are responsible for ensuring MIFU is followed. COO stated, regarding rectal probe disinfection issue not included in Quality Assurance Performance Improvement (QAPI) minutes for November to December 2023, January 2024 - “we have not gotten there yet, but it does not mean we did not discuss it.” During an interview on 2/14/24 at 10:10 a.m. with the Infection Prevention Manager (IPM), IPM stated the facility was part of a [hospital system] who had multiple hospitals in the state; in addition, the facility was part of a small group of three hospitals which shared a governing body and had a shared Infection Prevention Department. IPM stated she had oversight of three hospitals and there was a dedicated Infection Preventionist (IP) at each hospital. IPM further stated the three hospitals shared another IP who had oversight of surgical services for all three hospitals. IPM stated, in November 2023, she received a call from the Clinical Process Improvement Consultant (CPIC) for the facility’s hospital system regarding the facility’s use of rectal ultrasound probes. IPM stated, she was unaware if the facility used the rectal ultrasound probes, and she sent out an email to the Surgical Services Department at the facility to inquire about the use of the probes. IPM stated the hospital used the Spaulding Classification System (a nationally recognized infection control standard which is used to define the minimum level of disinfection required for a medical device) to determine how medical devices should be cleaned. IPM stated rectal ultrasound probes required High-level Disinfection (HLD- a cleaning process which achieves elimination of all microorganisms in or on a medical device, except for small numbers of bacterial spores) because the probe came in contact with mucous membranes (soft lining of body cavities and canals that lead to the outside of the body). IPM stated, she received an email response from the Surgical Services Manager who confirmed the rectal ultrasound probes were used in the operating room (OR) and reported the cleaning and disinfecting procedure did not include HLD. IPM stated she was unaware of the facility’s process for cleaning and disinfecting the probes until that date. IPM stated, at that time, the facility was instructed to stop the use of the probes as the cleaning and disinfection process was inadequate. During an interview on 2/14/24 at 2:42 p.m. with the Infection Prevention Registered Nurse (IP 1), IP 1 stated staff were expected to follow manufacturer’s IFU for all medical devices, for cleaning and disinfecting products. IP 1 further stated, it was his understanding that the rectal ultrasound probe manufacturer IFU allowed for low- level disinfection (a process that kills bacteria and some viruses on items that only come in contact with intact skin). IP 1 confirmed rectal ultrasound probes come in contact with mucus membranes and should be, at minimum, HLD according to the facility’s policy. During an interview on 2/15/24 at 9:30 a.m. with the Clinical Process Improvement Consultant (CPIC) for the facility’s hospital system, CPIC stated she worked for [hospital system name] which owned multiple hospitals in the state and the facility was a system hospital. CPIC stated, in November 2023, she received a concern from a staff member at a different hospital related to cleaning and disinfecting rectal ultrasound probes, so she reached out to all system hospitals to determine what their current process was. CPIC stated it was determined the facility was renting the rectal ultrasound probes from [vendor]. CPIC further stated, it was determined the facility was not cleaning and disinfecting the rectal ultrasound probes adequately. CPIC stated rectal ultrasound probes were considered semi-critical devices (any device that comes in contact with a mucus membrane) and required High Level Disinfection (HLD- a cleaning process which achieves elimination of all microorganisms in or on a medical device, except for small numbers of bacterial spores), at a minimum. CPIC confirmed the facility was not performing HLD on these devices. CPIC stated the facility was instructed to stop using the rectal ultrasound probes until an investigation was conducted. During an interview on 2/15/24 at 12 p.m. with the Director of Quality, Patient Safety, and Infection Control (DQI), the DQI stated in November 2023, she received a call from CPIC inquiring about the process the facility used to clean and disinfect rectal ultrasound probes. DQI stated the facility reported their process and were instructed to suspend using the probes because they were not HLD. During a review of the facility’s “Infection Prevention and Control Plan,” dated 3/16/23, the “Infection Prevention and Control Plan” indicated, a Risk Assessment was completed, and the facility identified one category of risk as “Infections Due to Disinfection or Sterilization Failures.” The facility did not identify patients undergoing procedures using the rectal ultrasound probe as a population at risk and did not identify HLD of the probes as an indicator. During a review of the facility’s policy and procedure (P&P) titled, “Infection Control Strategies for Handling Disinfection and Maintenance of Flexible Scopes, Rigid Endoscopes, Probes, Instruments,” dated 6/22/23, the P&P indicated, “The Spaulding Classification is used to define the minimum level of disinfection or sterilization required ... This classification system is based on the type of instrument used as well as the type of tissue exposed ... Semi-critical items= HLD required: devices contact mucous membranes or non-intact skin ... Endo cavity probes [a probe inserted into the human body] are heat sensitive, reusable Semi-critical devices that require HLD.” During a concurrent interview and record review on 2/15/24 at 3:45 p.m. with the Director of Accreditation and Licensing (DAL), the “List of [hospital] Patient Notification” was reviewed. DAL stated the facility identified a list of patients who had procedures using the rectal ultrasound probe and may have been affected by the failure to HLD the probes. DAL stated, the facility sent notification letters to all patients on the list. The list included a total of thirty-three patients. During a review of the facility (Healthcare System’s Name), [Facilities Group Name affiliated with (three) separately certified hospitals], document titled, “Infection Prevention and Control Plan,” dated 3/16/23, indicated, “Page 4 ... This document is a comprehensive evaluation, risk assessment. and prevention and control plan ... this process is completed annually. The risk assessment is completed at least annually and whenever significant changes occur ...The purpose of Infection Prevention and Control Department is to minimize the morbidity, mortality, and economic burden associated with healthcare associated infections (HAIs) through prevention and control endeavors in both patient and staff populations ... the most current CDC (Centers for Disease Control and Prevention, the nation’s leading science-based, data-driven, service organization that protects the public’s health.) NHSN (National Healthcare Safety Network-healthcare associated tracking system) and surveillance definitions and comparative database are utilized to evaluate patient outcomes ... Infection Prevention and Control is a facility wide patient safety component involving all departments. The Infection Preventionist, along with the Infection Prevention and Control Committee. Determines the specific focus of surveillance, education, and consultation effort on an ongoing basis ... Geographical Location, [Facilities Group Name affiliated with (three) separately certified hospitals], is a group of (Name ) area acute care facilities with 585 beds ... [Facilities Group Name affiliated with (three) separately certified hospitals], provides tertiary (high level of specialized care) care services for ... California ... Facilities Group Name affiliated with (three) separately certified hospitals], provides tertiary (high level of specialized care) care services for ... California ... Page 7 ... Authority and Responsibilities, The Governing Body and the [hospital] Infection Prevention and Control Committee members have the overall authority and responsibility for the Infection Prevention and Control Program...” 2. During a concurrent observation and interview with the Scrub Technician (ST 2) on 2/14/24 at 8:16 a.m. in the operating room (OR), ST 2 stated the surgical procedure had just finished and he was beginning the “pre-cleaning” process for the rectal ultrasound probe used in the procedure. During the pre-cleaning process, ST 2 was observed wiping the probe with disinfecting wipes beginning at the tip of the probe moving toward the top of the probe and ending at the cord which connects to the ultrasound monitor (in a dirty to clean direction). After wiping the probe, ST 2 placed the probe into a bin and stated, “Now it needs to dry for three minutes.” ST 2 left the probe in the bin for three minutes while performing other tasks. ST 2 then stated, it had been three minutes and he covered the bin with a red bag. The bin containing the probe was then sent in the elevator to the Sterile Processing Department (SPD). During a concurrent observation and interview with the Sterile Processing Technician (SPT 4) on 2/14/24 at 8:26 a.m. in the SPD, SPT 4 stated, he had just received the probe from the OR and was beginning the High-Level Disinfection process (a cleaning process which achieves elimination of all microorganisms in or on a medical device, except for small numbers of spores). SPT 4 stated a leak test (a process required to protect patients from infection that could result from leaks in the device and also protects the device from damage) was required for the probe to ensure there were no small holes in the probe. SPT 1 placed the leak tester on the end of the probe cord and pumped the pressure to a reading of 150 mm (millimeter of mercury- a measurement used to record pressure). Immediately after obtaining a pressure reading of 150 mm, SPT 1 stated, “It’s holding strong, so it passed the leak test.” SPT 4 did not monitor the pressure reading during the leak test for a specific amount of time. During an interview on 2/14/24 at 1:10 p.m. with the Surgical Services Manager (MSS 3), MSS 3 confirmed ST 1 should have wiped the rectal ultrasound probe with disinfecting wipes from the cord to the tip of the probe (clean to dirty direction). MSS 3 stated equipment should be wiped from clean to dirty to prevent cross contamination (spreading germs from dirty areas to clean areas). MSS 3 was unable to verbalize the IFU for the disinfecting wipes and stated, “We let it dry for three minutes to make sure it’s dried.” MSS was unaware the probe should have been dried with a cloth according to the Standard Work. During an interview on 2/14/24 at 2:42 p.m. with the Infection Prevention Registered Nurse (IP 1), IP 1 stated the IFU for the disinfecting wipes indicated a “wet time” of three minutes which meant the device should be maintained wet with the disinfecting product for three minutes and then dried with a cloth. During a concurrent interview and record review on 2/15/24 at 1:33 p.m. with the Sterile Processing Department Manager (SPDM), the manufacturer IFU for the rectal ultrasound probe was reviewed. SPDM confirmed, SPT 4 did not follow the IFU for leak testing the probe and should have waited 45 seconds to ensure the leak test was completed. During a review of the facility’s procedure for cleaning and disinfecting rectal ultrasound probes titled, “Standard Work- [manufacturer] Probes ‘model 888oe and 88848’ High Level Disinfection (HLD),” dated 1/31/24, the Standard Work indicated, “Pre-cleaning occurs at the point of use ... clean probe using a manufacturer approved disinfectant wipe ... thoroughly dry the probe with a soft cloth.” The Standard Work further indicated a leak test was required for rectal ultrasound probes with each cleaning process, “Perform leak test per manufacturers recommendation.” During a review of the manufacturer’s instructions for use (IFU) for the disinfecting wipes used on the rectal ultrasound probe, the IFU indicated, “Ultrasound Transducers and Probes ... use germicidal cloth to thoroughly wet the surface. Allow surface to remain wet three minutes ...” During a review of the manufacturer’s IFU for the rectal ultrasound probe, titled, “[manufacturer] Care and Cleaning,” issued 2022, the IFU indicated, “Leak Testing Procedure ... pump to increase the pressure to 150 mm ... once 150 is reached, observe the pressure for 45 seconds ... if the pressure is stable, place in the water tank ...” 3. During a concurrent observation and interview on 2/13/24, at 11:48 AM, of the Operating Room 5 (five), located on Level- A, North Tower building and interview with the Manager Surgical Services (MSS 3) and with the Quality Assurance Coordinator (QAC 3), there were three-cylinder tanks attached to the anesthesia cart machine. The first was an “oxygen tank (metal cylinders that store oxygen under pressure)”, the middle was a “compressed air (air that is pressurised to greater than atmospheric pressure)” tank, and the third was “nitrous oxide” (colorless, odorless anesthetic adjuvant) tank. The compressed air tank, which was the middle tank, had a light to dark brown discoloration around the tank. The MSS 3 wiped the tank with a dry paper towel and a light to dark discoloration around the tank came off which left a mark on the dry the paper towel. MSS 3 stated, it was “not dirt”, it was “rust” and it (compressed air tank) was not supposed to be in the OR. During an interview on 2/14/24, at 3:01 PM, with the Infection Preventionist (IP 1), the photo of the compressed air tank with light to dark brown discoloration around the tank observed in the OR was shown to him. The IP 1 stated, it should not be in the OR and staff should do hand hygiene (means cleaning the hands by using either handwashing [washing hands with soap and water], antiseptic hand wash, antiseptic hand rub [i.e. alcohol-based hand sanitizer including foam or gel]). Review of the facility’s Policy and Procedure titled, “Purchasing, Storing and Usage of Medical Gas Cylinders”, with the last revised date of 4/21/22 indicated, “xxx (name of the facility) shall provide a safe, systemic methods of ... storing, ... using medical compressed gas cylinders. ... PRECAUTIONS/COMPLICATIONS: ... B. Aged poorly maintained rusted or modified cylinders should not be used...” 4. During a concurrent observation and interview on 2/13/24 at 11:50 a.m., with the Sterile Processing Department Manager (SPDM), the sterile instrument storage area was observed. On the bottom rack of a three-tiered rack labeled “plastics”, there were two rigid instrument cases observed stored directly on top of a sterile soft wrapped instrument pack. SPDM stated rigid instrument cases should not be stacked on top of soft wrapped instrument packs because the rigid cases could puncture the soft packs and contaminate the instruments. SPDM stated the soft pack needed to be re-sterilized (made completely free of contamination from bacteria, virus, or spores). During a review of the facility’s policy and procedure (P&P), dated 6/29/21, the P&P indicated, “Sterile items will be stored under the following conditions ... wrapped packages above (not below) rigid container systems when they are stored on the same shelf ... positioned so that items are not crushed or punctured this jeopardizing their sterility.” 5. During a concurrent observation and interview on 2/13/24, at 12:20 PM, of the Post Anesthesia Care Unit (PACU), located on Level-A, North Tower, and the Manager Surgical Services (MSS 3), inside the Clean Utility Room, on the bottom rack of a three tier shelf-cart were six (6) plastic containers of sterile water inhalation with the expiration date of “2023-02-08”. The MSS 3 stated, they were (Brand Name) sterile water used as humidifier (to add moisture to the dry oxygen from an oxygen source). The MSS 3 stated, “we don’t use” expired items, it was “missed”, and it has potential for “adverse reaction,” like infection. Review of the facility’s P&P titled, “Stock Rotation and Outdates”, with the effective date of 1/19/23 indicated, “Objective: To ensure utilization of single use disposable medical supplies before expiration dates ... Procedure - Outdating: 1. Materials Management staff will review all items in regular stock ... and remove those expiring within 30 days, replacing those items with newer stock. ... Expiration outdating of supplies ... will be the responsibility of the individual units ... “”

    Rule A0309. Standard-level. From a complaint.

  • Infection Control Program

    The inspectors’ words, 1,737 words

    “INFECTION CONTROL PROGRAM CFR(s): 482.42(a)(1) The hospital infection prevention and control program, as documented in its policies and procedures, employs methods for preventing and controlling the transmission of infections within the hospital and between the hospital and other institutions and settings; This Standard is not met as evidenced by: 33922 Based on observation, interview, and record review the facility failed to ensure: 1. Rectal ultrasound probes (probe inserted into the rectum which uses sound waves to produce images during a surgical procedure) were cleaned and disinfected according to the manufacturer’s instructions for use (IFU) and facility policy. As a result of this failure, thirty-three patients were potentially exposed to infectious diseases such as hepatitis (inflammation of the liver caused by infection) or human immunodeficiency virus (HIV- a virus that attacks the immune system). 2. Staff followed the facility’s Standard Work (a document with step-by-step instructions) and manufacturer’s instructions for use (IFU) when cleaning and disinfecting a rectal ultrasound probe (probe inserted into the rectum which uses sound waves to produce images during a surgical procedure), after a procedure. This failure resulted in the potential that the probe was not adequately disinfected. Findings: 1. During an interview on 2/15/24 at 9:30 a.m. with the Clinical Process Improvement Consultant (CPIC) for the facility’s hospital system, CPIC stated she worked for [hospital system name] which owned multiple hospitals in the state and the facility was a system hospital. CPIC stated, in November 2023, she received a concern from a staff member at a different hospital related to cleaning and disinfecting rectal ultrasound probes, so she reached out to all system hospitals to determine what their current process was. CPIC stated it was determined the facility was renting the rectal ultrasound probes from [vendor]. CPIC further stated, it was determined the facility was not cleaning and disinfecting the rectal ultrasound probes adequately. CPIC stated rectal ultrasound probes were considered semi-critical devices (any device that comes in contact with a mucus membrane) and required High Level Disinfection (HLD- a cleaning process which achieves elimination of all microorganisms in or on a medical device, except for small numbers of bacterial spores), at a minimum. CPIC confirmed the facility was not performing HLD on these devices. CPIC stated the facility was instructed to stop using the rectal ultrasound probes until an investigation was conducted. During an interview on 2/14/24 at 1:10 p.m. with the Surgical Services Manager (MSS 3), MSS 3 stated the facility performed surgical procedures using a rectal ultrasound probe. MSS 3 stated the facility contracted with a vendor who brought the rectal ultrasound probe to the Operating Room (OR) to be used for a procedure and OR staff cleaned the probe with a disinfecting wipe, covered the probe with a plastic sheath, and used it during the procedure. MSS stated, after the procedure, OR staff removed the plastic sheath, cleaned the probe with a disinfecting wipe, and gave the probe back to the vendor. MSS 3 confirmed the facility used the Spaulding Classification System (a nationally recognized infection control standard which is used to define the minimum level of disinfection required for a medical device) to determine how medical devices should be cleaned. MSS 3 confirmed, according to Spaulding Classification, rectal ultrasound probes come in contact with mucus membranes (soft lining of body cavities and canals that lead to the outside of the body) and required High-Level Disinfection at a minimum. MSS 3 stated she had worked at the facility for approximately four years and stated, “This is the way it was always done so I didn’t question it.” During an interview on 2/14/24 at 2:42 p.m. with the Infection Prevention Registered Nurse (IP 1), IP 1 stated staff were expected to follow manufacturer’s IFU for all medical devices, for cleaning and disinfecting products. IP 1 further stated, it was his understanding that the rectal ultrasound probe manufacturer IFU allowed for low- level disinfection (a process that kills bacteria and some viruses on items that only come in contact with intact skin). IP 1 confirmed rectal ultrasound probes come in contact with mucus membranes and should be, at minimum, HLD according to the facility’s policy. During a concurrent interview and record review on 2/15/24 at 3:45 p.m. with the Director of Accreditation and Licensing (DAL), the “List of [hospital] Patient Notification” was reviewed. DAL stated the facility identified a list of patients who had procedures using the rectal ultrasound probe and may have been affected by the failure to HLD the probes. DAL stated, the facility sent notification letters to all patients on the list. The list included a total of thirty-three patients. During a review of the manufacturer’s IFU for the rectal ultrasound probe, titled “[Manufacturer] Care and Cleaning”, dated 2022, the IFU indicated, “The CDC classifies medical devices according to their use. For each classification, they specify the level of disinfection/sterilization processing that is required before use ... Classification: Semi-Critical- device that contacts mucus membranes. Required Processing: Immediate cleaning and high-level disinfection or sterilization.” During a review of the manufacturer’s IFU for the disinfecting wipes the facility used on the rectal ultrasound probe, the IFU indicated, “This product is not to be used as a terminal sterilant/HLD on any surface or instrument that is introduced directly into the human body ... or contacts intact mucus membranes ... this product may be used to preclean medical devices prior to HLD.” During a review of the facility’s policy and procedure (P&P) titled, “Infection Control Strategies for Handling Disinfection and Maintenance of Flexible Scopes, Rigid Endoscopes, Probes, Instruments,” dated 6/22/23, the P&P indicated, “The Spaulding Classification is used to define the minimum level of disinfection or sterilization required ... This classification system is based on the type of instrument used as well as the type of tissue exposed ... Semi-critical items= HLD required: devices contact mucous membranes or non-intact skin ... Endo cavity probes [a probe inserted into the human body] are heat sensitive, reusable Semi-critical devices that require HLD.” 2. During a concurrent observation and interview with the Scrub Technician (ST 2) on 2/14/24 at 8:16 a.m. in the operating room (OR), ST 2 stated the surgical procedure had just finished and he was beginning the “pre-cleaning” process for the rectal ultrasound probe used in the procedure. During the pre-cleaning process, ST 2 was observed wiping the probe with disinfecting wipes beginning at the tip of the probe moving toward the top of the probe and ending at the cord which connects to the ultrasound monitor (in a dirty to clean direction). After wiping the probe, ST 2 placed the probe into a bin and stated, “Now it needs to dry for three minutes.” ST 2 left the probe in the bin for three minutes while performing other tasks. ST 2 then stated, it had been three minutes and he covered the bin with a red bag. The bin containing the probe was then sent in the elevator to the Sterile Processing Department (SPD). During a concurrent observation and interview with the Sterile Processing Technician (SPT 4) on 2/14/24 at 8:26 a.m. in the SPD, SPT 4 stated, he had just received the probe from the OR and was beginning the High-Level Disinfection process (a cleaning process which achieves elimination of all microorganisms in or on a medical device, except for small numbers of spores). SPT 4 stated a leak test (a process required to protect patients from infection that could result from leaks in the device and also protects the device from damage) was required for the probe to ensure there were no small holes in the probe. SPT 1 placed the leak tester on the end of the probe cord and pumped the pressure to a reading of 150 mm (millimeter of mercury- a measurement used to record pressure). Immediately after obtaining a pressure reading of 150 mm, SPT 1 stated, “It’s holding strong, so it passed the leak test.” SPT 4 did not monitor the pressure reading during the leak test for a specific amount of time. During an interview on 2/14/24 at 1:10 p.m. with the Surgical Services Manager (MSS 3), MSS 3 confirmed ST 1 should have wiped the rectal ultrasound probe with disinfecting wipes from the cord to the tip of the probe (clean to dirty direction). MSS 3 stated equipment should be wiped from clean to dirty to prevent cross contamination (spreading germs from dirty areas to clean areas). MSS 3 was unable to verbalize the IFU for the disinfecting wipes and stated, “We let it dry for three minutes to make sure it’s dried.” MSS was unaware the probe should have been dried with a cloth according to the Standard Work. During an interview on 2/14/24 at 2:42 p.m. with the Infection Prevention Registered Nurse (IP 1), IP 1 stated the IFU for the disinfecting wipes indicated a “wet time” of three minutes which meant the device should be maintained wet with the disinfecting product for three minutes and then dried with a cloth. During a concurrent interview and record review on 2/15/24 at 1:33 p.m. with the Sterile Processing Department Manager (SPDM), the manufacturer IFU for the rectal ultrasound probe was reviewed. SPDM confirmed, SPT 4 did not follow the IFU for leak testing the probe and should have waited 45 seconds to ensure the leak test was completed. During a review of the facility’s procedure for cleaning and disinfecting rectal ultrasound probes titled, “Standard Work- [manufacturer] Probes ‘model 888oe and 88848’ High Level Disinfection (HLD),” dated 1/31/24, the Standard Work indicated, “Pre-cleaning occurs at the point of use ... clean probe using a manufacturer approved disinfectant wipe ... thoroughly dry the probe with a soft cloth.” The Standard Work further indicated a leak test was required for rectal ultrasound probes with each cleaning process, “Perform leak test per manufacturers recommendation.” During a review of the manufacturer’s instructions for use (IFU) for the disinfecting wipes used on the rectal ultrasound probe, the IFU indicated, “Ultrasound Transducers and Probes ... use germicidal cloth to thoroughly wet the surface. Allow surface to remain wet three minutes ...” During a review of the manufacturer’s IFU for the rectal ultrasound probe, titled, “[manufacturer] Care and Cleaning,” issued 2022, the IFU indicated, “Leak Testing Procedure ... pump to increase the pressure to 150 mm ... once 150 is reached, observe the pressure for 45 seconds ... if the pressure is stable, place in the water tank ...””

    Rule A0749. Standard-level. From a complaint.

  • Infection Control Surveillance, Prevention

    The inspectors’ words, 437 words

    “INFECTION CONTROL SURVEILLANCE, PREVENTION CFR(s): The infection prevention and control program includes surveillance, prevention, and control of HAIs, including maintaining a clean and sanitary environment to avoid sources and transmission of infection, and addresses any infection control issues identified by public health authorities; and This Standard is not met as evidenced by: 31794 Based on observation, interview, and record review the facility failed to ensure sanitary and clean environment when one rusty cylinder tank of compressed air (air that is pressurised to greater than atmospheric pressure) was observed in the Operating Room. This deficient practice had the potential for cross contamination (transfer of harmful bacteria from one person, object or place to another) to happen. Findings: During an observation of the Operating Room (OR, a sterile location where surgical procedures are performed), located on Level- A, North Tower building and interview on 2/13/24, at 11:48 AM, with the Manager Surgical Services (MSS 3) and with the Quality Assurance Coordinator (QAC 3), Room 5 (five) of the OR was observed. There were three-cylinder tanks attached to the anesthesia cart machine. The first was an “oxygen tank (metal cylinders that store oxygen under pressure)”, the middle was a “compressed air (air that is pressurised to greater than atmospheric pressure)” tank, and the third was “nitrous oxide” (colorless, odorless anesthetic adjuvant) tank. The compressed air tank, which was the middle tank, had a light to dark brown discoloration around the tank. The MSS 3 wiped the tank with a dry paper towel and a light to dark discoloration around the tank came off which left a mark on the dry the paper towel. MSS 3 stated, it was “not dirt”, it was “rust” and it (compressed air tank) was not supposed to be in the OR. During an interview on 2/14/24, at 3:01 PM, with the Infection Preventionist (IP 1), the photo of the compressed air tank with light to dark brown discoloration around the tank observed in the OR was shown to him. The IP 1 stated, it should not be in the OR and staff should do hand hygiene (means cleaning the hands by using either handwashing [washing hands with soap and water], antiseptic hand wash, antiseptic hand rub [i.e. alcohol-based hand sanitizer including foam or gel]). Review of the facility’s Policy and Procedure titled, “Purchasing, Storing and Usage of Medical Gas Cylinders”, with the last revised date of 4/21/22 indicated, “xxx (name of the facility) shall provide a safe, systemic methods of ... storing, ... using medical compressed gas cylinders. ... PRECAUTIONS/COMPLICATIONS: ... B. Aged poorly maintained rusted or modified cylinders should not be used ... .””

    Rule A0750. Standard-level. From a complaint.

  • Ic Professional Responsibilities Policies

    The inspectors’ words, 1,195 words

    “IC PROFESSIONAL RESPONSIBILITIES POLICIES CFR(s): Standard: Leadership responsibilities (2) The infection preventionist(s)/infection control professional(s) is responsible for: (i) The development and implementation of hospital-wide infection surveillance, prevention, and control policies and procedures that adhere to nationally recognized guidelines. This Standard is not met as evidenced by: 33922 Based on interview and record review, the facility failed to oversee the process of cleaning and disinfecting rectal ultrasound probes (probe inserted into the rectum which uses sound waves to produce images during a surgical procedure) and failed to identify the facility’s process for cleaning and disinfection of rectal ultrasound probes did not adhere to nationally recognized guidelines. As a result of this failure, thirty-three patients were potentially exposed to infectious diseases such as hepatitis (inflammation of the liver caused by infection) or human immunodeficiency virus (HIV- a virus that attacks the immune system). Findings: During an interview on 2/14/24 at 10:10 a.m. with the Infection Prevention Manager (IPM), IPM stated the facility was part of a [hospital system] who had multiple hospitals in the state; in addition, the facility was part of a small group of three hospitals which shared a governing body and had a shared Infection Prevention Department. IPM stated she had oversight of three hospitals and there was a dedicated Infection Preventionist (IP) at each hospital. IPM further stated the three hospitals shared another IP who had oversight of surgical services for all three hospitals. IPM stated, in November 2023, she received a call from the Clinical Process Improvement Consultant (CPIC) for the facility’s hospital system regarding the facility’s use of rectal ultrasound probes. IPM stated, she was unaware if the facility used the rectal ultrasound probes, and she sent out an email to the Surgical Services Department at the facility to inquire about the use of the probes. IPM stated the hospital used the Spaulding Classification System (a nationally recognized infection control standard which is used to define the minimum level of disinfection required for a medical device) to determine how medical devices should be cleaned. IPM stated rectal ultrasound probes required High-level Disinfection (HLD- a cleaning process which achieves elimination of all microorganisms in or on a medical device, except for small numbers of bacterial spores) because the probe came in contact with mucous membranes (soft lining of body cavities and canals that lead to the outside of the body). IPM stated, she received an email response from the Surgical Services Manager who confirmed the rectal ultrasound probes were used in the operating room (OR) and reported the cleaning and disinfecting procedure did not include HLD. IPM stated she was unaware of the facility’s process for cleaning and disinfecting the probes until that date. IPM stated, at that time, the facility was instructed to stop the use of the probes as the cleaning and disinfection process was inadequate. During an interview on 2/14/24 at 1:10 p.m. with the Surgical Services Manager (MSS 3), MSS 3 stated she was contacted by the Infection Prevention Department regarding the use of rectal ultrasound probes in the Surgical Services Department and responded that the facility performed surgical procedures using the rectal ultrasound probe in the OR. MSS 3 stated the facility contracted with a vendor who brought the rectal ultrasound probe to the OR to be used for a procedure and OR staff cleaned the probe with a disinfecting wipe, covered the probe with a plastic sheath, and used it during the procedure. MSS 3 stated, after the procedure, OR staff removed the plastic sheath, cleaned the probe with a disinfecting wipe, and gave the probe to back to the vendor. MSS 3 confirmed, according to Spaulding Classification, rectal ultrasound probes come in contact with mucus membranes and required High-Level Disinfection at a minimum. MSS 3 stated she had worked at the facility for approximately four years and stated, “This is the way it was always done so I didn’t question it.”MSS 3 stated the facility was instructed to stop the use of the probes until further notice. During an interview on 2/14/24 at 2:42 p.m. with the Infection Prevention Registered Nurse (IP 1), IP 1 stated he oversaw infection control practices in the ORs and Sterile Processing Departments for three hospitals. He stated his responsibilities included surveillance of instrument processing including HLD procedures. IP 1 stated, “It is my understanding the hospital followed the manufacturer instructions for use (IFU) [for the rectal ultrasound probe].” IP 1 confirmed rectal ultrasound probes come in contact with mucus membranes and should be, at minimum, HLD according to the facility’s policy and nationally recognized standards of practice. During an interview on 2/15/24 at 12 p.m. with the Director of Quality, Patient Safety, and Infection Control (DQI), the DQI stated in November 2023, she received a call from CPIC inquiring about the process the facility used to clean and disinfect rectal ultrasound probes. DQI stated the facility reported their process and were instructed to suspend using the probes because they were not HLD. During a review of the facility’s “Infection Prevention and Control Plan,” dated 3/16/23, the “Infection Prevention and Control Plan” indicated, a Risk Assessment was completed, and the facility identified one category of risk as “Infections Due to Disinfection or Sterilization Failures.” The facility did not identify patients undergoing procedures using the rectal ultrasound probe as a population at risk and did not identify HLD of the probes as an indicator. During a review of the facility’s policy and procedure (P&P) titled, “Infection Control Strategies for Handling Disinfection and Maintenance of Flexible Scopes, Rigid Endoscopes, Probes, Instruments,” dated 6/22/23, the P&P indicated, “The Spaulding Classification is used to define the minimum level of disinfection or sterilization required ... This classification system is based on the type of instrument used as well as the type of tissue exposed ... Semi-critical items= HLD required: devices contact mucous membranes or non-intact skin ... Endo cavity probes [a probe inserted into the human body] are heat sensitive, reusable Semi-critical devices that require HLD.” *The facility’s P&P referenced the Centers for Disease Control’s (CDC- national public health agency that develops scientific based guidelines to prevent infectious disease) definitions of Semi-critical items and High-Level Disinfection. (www.cdc.gov/hicpac/pdf/guidelines/disinfection_Nov_2008.pdf). During a review of the manufacturer’s IFU for the rectal ultrasound probe, titled, “[manufacturer] Care and Cleaning,” issued 2022, the IFU indicated, “The CDC classifies medical devices according to their use. For each classification, they specify the level of disinfection/sterilization processing that is required before use ... Classification: Semi-Critical- device that contacts mucus membranes. Required Processing: Immediate cleaning and high-level disinfection or sterilization.” During a review of the facility’s job description titled, “Infection Preventionist, Acute,” the job description indicated the Infection Preventionist responsibilities included, “Coordinates hospital-wide infection control program including performance improvement to identify and prevent healthcare associated infections ...Makes rounds for the purpose of case finding, environmental sanitation monitoring, and supervision of infection control practices to support compliance with recommended practices ...” During a review of the facility’s “Infection Prevention and Control Plan,” dated 3/16/23, the “Infection Prevention and Control Plan” indicated, “The Governing Body and the [hospital] Infection Prevention and Control Committee members have the overall authority and responsibility for the Infection Prevention and Control Program.””

    Rule A0772. Standard-level. From a complaint.

  • System Ic-Abx Stewardship Circumstances

    The inspectors’ words, 672 words

    “SYSTEM IC-ABX STEWARDSHIP CIRCUMSTANCES CFR(s): §482.42(d)(1) Standard: Unified and integrated infection prevention and control and antibiotic stewardship programs for multi-hospital systems. (1) The unified and integrated infection prevention and control and antibiotic stewardship program sare established in a manner that takes into account each member hospital’s unique circumstances and any significant differences in patient populations and services offered in each hospital; This Standard is not met as evidenced by: 33922 Based on interview and record review, the facility failed to ensure the facility’s Infection Control Plan was specific to the population served and the services provided at the hospital. This failure resulted in the potential for facility specific infection control risks to go unaddressed. Findings: During an interview on 2/13/24 at 10:08 am, with the Director of Accreditation and Licensing (DAL), DAL stated, stated the facility had 153 beds. During a review of the list of the facility’s services provided by DAL on 2/14/24, the facility’s services included: General Medical Surgical Services, Critical Care Services, Emergency Services, Surgery, Radiology (imaging such as x-rays), Nuclear Medicine (specialized area of medicine that uses very small amounts of high-speed energy waves to examine organ function), and Interventional Neuroradiology (advanced medical specialty using three dimensional imaging to insert catheters through the groin area which are threaded into the brain). During a review of the facility’s “Infection Prevention and Control Plan,” dated 3/16/23, the “Infection Prevention and Control Plan” indicated, “[group of separately certified hospitals] is a group of bay area acute care facilities with 585 beds ... [group of separately certified hospitals] provides tertiary (high level of specialized care) care services for Northern California.” The Infection Control Plan further indicated: Programs and Services: included Cardiac and Transplant Services, Women and Children’s Services, Pediatric Hematology/Oncology (cancer services). Most Common Admitting Diagnoses: included single live born infant delivery and post-term pregnancy. Most Common Surgical Procedures: included delivery of products of conception (placenta- afterbirth). Evaluation of the 2022 Infection Control Plan: included data analysis of indicators from 2022 including Surgical Site Infections (SSIs), Hand Hygiene, use of Immediate Use Steam Sterilization (IUSS-process of sterilizing surgical instruments rapidly for emergencies), and Surgical Instrument processing audits. During a review of the facility’s “Infection Control and Epidemiology Committee Meeting” minutes from September 2023 to January 2024, the minutes indicated, the committee included staff members from each of the separately certified hospitals. Data for Surgical Site Infections and IUSS was reported to the committee, however the data was not specific to each hospital. During a concurrent interview and record review on 2/14/24 at 10:10 a.m. with the Infection Prevention Manager (IPM), the facility’s “Infection Prevention and Control Plan” dated 3/16/23 was reviewed. IPM stated the facility was part of a [hospital system] who had multiple hospitals in the state; in addition, the facility was part of a small group of three separately certified hospitals which shared a governing body and had a shared Infection Prevention Department. IPM stated the hospital’s Infection Control Plan was developed for [hospital system] and all hospitals within [system name] used the same Infection Control Plan. IMP stated the Summary of 2022 Goals and Outcomes portion was not specific to the facility but was a combined summary of the three separately certified hospitals together. IPM stated the SSI, Hand Hygiene, IUSS data reviewed in the plan was a combination of all three separately certified hospitals and did not reflect the outcomes of the facility specifically. IPM confirmed facility specific outcomes were not included in the Infection Control Plan. IPM further stated the risk assessment portion of the Infection Control Plan was not specific to the facility but was based on risks identified from the three separately certified hospitals together. IPM stated, the Infection Control and Epidemiology Committee Meeting reviewed data from all three separately certified hospitals combined and data was not specific to the facility. IPM stated, the facility did not offer Women and Children’s Services, Transplant Services, or Pediatric Hematology/Oncology services and confirmed the Infection Control Plan was not specific to the facility’s population served or services provided.”

    Rule A0786. Standard-level. From a complaint.

  • Operating Room Policies

    The inspectors’ words, 5,721 words

    “OPERATING ROOM POLICIES CFR(s): 482.51(b) Surgical services must be consistent with needs and resources. Policies governing surgical care must be designed to assure the achievement and maintenance of high standards of medical practice and patient care. This Standard is not met as evidenced by: 33922 Based on observation, interview and record review, the facility failed to ensure surgical services maintained oversight of Department Services operational policies and procedures for Infection Control, Sterile Processing Department (SPD an area within the hospital in which medical/surgical supplies and equipment, are cleaned, prepared, processed, stored, and issued for patient care), Operating Room (OR sterile location where surgical procedures were performed), and Contract Services when: 1. Rectal ultrasound probes (probe inserted into the rectum which uses sound waves to produce images during a surgical procedure) were cleaned and disinfected according to the manufacturer’s instructions for use (IFU) and facility policy. As a result of this failure, thirty-three patients were potentially exposed to infectious diseases such as hepatitis (inflammation of the liver caused by infection) or human immunodeficiency virus (HIV- a virus that attacks the immune system). 2. Staff did not follow the facility’s Standard Work (a document with step-by-step instructions) and manufacturer’s instructions for use (IFU) when cleaning and disinfecting a rectal ultrasound probe (probe inserted into the rectum which uses sound waves to produce images during a surgical procedure), after a procedure. This failure resulted in the potential that the probe was not adequately disinfected. 3. One rusty cylinder tank of compressed air (air that is pressurized to greater than atmospheric pressure) was in Operating Room 5. This deficient practice had the potential for cross contamination (transfer of harmful bacteria from one person, object or place to another) to happen. 4. Sterile surgical instruments (tools used to perform surgery) were stored to prevent contamination when rigid instrument cases were stored on top of soft wrapped instrument packs. This failure resulted in the potential for contaminated surgical instruments. 5. Total of six (6) expired plastic containers of sterile water humidifier with expiration date of “2/8/23” were stored in the bottom of the three-tiered rack inside the Clean Room of the Post Anesthesia Care Unit (PACU, is a critical care unit and specialty that focuses on the recovery and treatment of patients immediately following surgical procedures and anesthesia). This failure resulted in the potential cross contamination (transfer of harmful bacteria from one person, object or place to another) to happen. The deficient practices resulted in the facility’s inability to provide quality healthcare in a safe environment. Findings: 4. During a concurrent observation and interview on 2/13/24 at 11:50 a.m., with the Sterile Processing Department Manager (SPDM), the sterile instrument storage area was observed. On the bottom rack of a three-tiered rack labeled “plastics”, there were two rigid instrument cases observed stored directly on top of a sterile soft wrapped instrument pack. SPDM stated rigid instrument cases should not be stacked on top of soft wrapped instrument packs because the rigid cases could puncture the soft packs and contaminate the instruments. SPDM stated the soft pack needed to be re-sterilized (made completely free of contamination from bacteria, virus, or spores). During a review of the facility’s policy and procedure (P&P), dated 6/29/21, the P&P indicated, “Sterile items will be stored under the following conditions ... wrapped packages above (not below) rigid container systems when they are stored on the same shelf ... positioned so that items are not crushed or punctured this jeopardizing their sterility.” 31794 5. During a concurrent observation and interview on 2/13/24, at 12:20 PM, with the Manager Surgical Services (MSS 3), the Clean Utility Room of the Post Anesthesia Care Unit (PACU), located on Level-A, North Tower, was observed. Inside the Clean Utility Room of the PACU, the bottom rack of a three tier shelf-cart had six (6) plastic containers of sterile water inhalation with the expiration date of “2023-02-08”. The MSS 3 stated, they were sterile water used as humidifier (to add moisture to the dry oxygen from an oxygen source). The MSS 3 acknowledged, they were expired, “we don’t use” expired items, it was “missed”, and expired items had the potential for “adverse reaction,” like infection. Review of the facility’s P&P titled, “Stock Rotation and Outdates”, with the effective date of 1/19/23 indicated, “Objective: To ensure utilization of single use disposable medical supplies before expiration dates ... Procedure - Outdating: 1. Materials Management staff will review all items in regular stock ... and remove those expiring within 30 days, replacing those items with newer stock. ... Expiration outdating of supplies ... will be the responsibility of the individual units ... “ 28225 Findings: 1. During a group interview on 2/5/24, at 10:07 AM, at (Hospital) H 1 with the Director of Accreditation and Licensing (DAL), Manager of Accreditation and Licensing (MAL), Director of Quality, Patient Safety, and Infection Control (DQI), Chief Nursing Executive (CNE), and Infection Control Manager (ICM), the DQI stated, in November 2023 the facility received an email notification from (Healthcare System’s Name) there may be potential patients at risk regarding infection control issues with the use of the ultrasound rectal probes. The DQI stated, the email contained instruction to reach out to the local managers (of hospitals operating under (Healthcare System’s Name), [Facilities Group Name affiliated with (three) separately certified hospitals] to evaluate the process. The DQI stated, the facility’s use of the ultrasound rectal probe dated back ten years and it was a rented equipment. The DQI further stated, that before the hospital was notified of the rectal probe disinfection issue, the staff performed low level disinfection (LLD, a process that kills bacteria and some viruses on items that only come in contact with intact skin) prior to using the probe and the re-processing (cleaning, disinfection, and sterilization of reusable medical equipment/devices) of the ultrasound rectal probe did not include high-level disinfection (HLD, a cleaning process which achieves elimination of all microorganisms in or on medical device, except for small number of bacterial spores). The DQI further stated, the facility suspended the use of the rectal probe, identified the patients at risk, sent notification letters to patients at risk, and notified local and state agencies. The use of the rectal probe was re-launched sometime in December 2023. During a review of facility’s document titled, “(Contractor’s Name) Rectal Probe Review Timeline”, received 2/5/24 indicated, “11/13/2023, 9:55 AA, Systems (Healthcare System) e-mail inform and action needed - HLD rectal probes, sites need to take immediate action to stop the use of inadequate disinfected devices on patients and implement an effective HDL process. 1. Identify all your usable devices that contact mucous membranes or sterile body sites., 2. Stop use of all devices identified in item one with inadequate HDL., 3. Investigate the current process and ensure appropriate HDL sterilization processes in place for MIFU., 4. Perform and document a risk assessment., 5. Resume use of these devices only when an appropriate disinfection* process is in place ... Please note : We are in the process validated facts and may have additional guidance as we learn more information we have reached out the company and are awaiting their response ... 11/14-15/2023 ... IC (Infection Control) fact finding and investigation + (plus) suspend use of probes ... 11/30/2023, Initiate Training, Education and Communication to Staff + local audits ... 12/11 and 15/2023, Relaunch of (Contractor’s Name) (rectal) Probe at H 1, H 2, H 3 (12/15) ... 1/8/2024, [Facilities Group Name affiliated with (three) separately certified hospitals] Notify CDPH ... 2/5/24, To date ... 179 [ Facilities Group Name affiliated with (three) separately certified hospitals] patients were notified ... “ Review of the facility letter sent to the State Agency [SA, California Department of Public Health (CDPH, ensures compliance with state licensing laws and federal certification regulations)], dated 1/8/24 indicated, “Notice of rectal probe disinfection process issue... we have newly learned that the disinfection process performed on this equipment did not meet the required high level disinfection (“HDL”) process for reusable rectal probes ... Immediate actions taken: We suspended the use of all reusable rectal probes ... 2. We ensured that an appropriate level of disinfection or sterilization is in place ... Next steps: 1. Patients identified as having a potential exposure are being notified ... 2. We are offering these patients free Hepatitis C (liver infection caused by the hepatitis C virus), Hepatitis B (inflammation of the liver by the hepatitis B virus) and HIV (HIV- a virus that attacks the immune system) tests.” During an observation and interview on 2/6/24 at 8:49 AM, at H 1, with VR, in the Operating Room (OR, sterile location where surgical procedures were performed) suite, VR stated, rectal probe model 8848 was used during the procedure (2/6/24). VR stated, whenever a rectal probe was needed for a procedure, he or another VR brought the rectal probe from the contractor facility to the hospital [(one of (three) separately certified hospitals) where it was scheduled to be used. VR stated, before the hospital was notified of the rectal probe disinfection issue, after the procedure he (VR) wiped the rectal probe thoroughly with the disinfectant wipe, put it inside the rectal probe container, and brought it back with him to the contractor facility. VR stated, he’s brought the rectal probe from the contractor facility to the hospital for the procedures since “a few years”. VR said he learned (was trained) how to disinfect the rectal probe “on the job”. VR stated, he had no documentation (from contractor) to verify competency (ability to do something successfully, effectively, or efficiently) with disinfection/decontamination of the rectal probe. VR further stated, after the rectal probe was brought back to the contractor facility, he did not know if further decontamination of the rectal probe was done at the contractor facility or before the rectal probe was reused for another procedure. Review of the facility,(Healthcare System’s Name), [Facilities Group Name affiliated with (three) separately certified hospitals], Policy and Procedures (P&P) titled, “Vendors and Sales Representatives, Special Instruments/Equipment /Supplies Guidelines in the Surgical Services Department”, revised 6/16/22 indicated, “Purpose to outline responsibilities and provide guidelines for vendor activities involving the Surgical Services department ... Scheduling and Approvals ... [Facilities Group Name affiliated with (three) separately certified hospitals] Surgical Services arranging ... 1 ... b. vendors are notified in a timely manner to allow for instrument and supplies to be prepared for the case ... 3 .... e. Manager/Supervisor/Service Leader or designee will arrange for staff education with the vendor prior to using new or unfamiliar instruments or equipment... f. Equipment or instruments may not be used during a procedure without appropriate education and or support for staff ... Sterile Processing Departments, 1 ... vendors must check in at SPD prior to entry. 2. The instrument/implant company (contractor) is responsible for delivery and pickup of instruments and implants ... 5. Pre-Procedure sets will arrive at least 24-48 hours ... a. Instruments/implant sets must be inspected, cleaned, and decontaminated, and sterilized by [Facilities Group Name affiliated with (three) separately certified hospitals] staff prior to use ... Post Procedure, 1. SPD staff will process sets through the washer/decontaminator or hand wash, if needed. Inspect for cleanliness and organize the instruments and sets. SPD staff will then place them in a specified card/area for vendor pickup ... The Operating Room ... 8 The Circulating RN ... Confirm, prior to the start of the procedure that the loaner instruments have been processed at [Facilities Group Name affiliated with (three) separately certified hospitals] ...” During a review of ( Manufacturer’s Name), titled, “Product Data Sheet, 8848 Endo Cavity Biplane Transducer”, dated July 2019, indicated, “The 8848 (Model) Endo Cavity Biplane Transducer [used to visualize (see) structures from inside body] design for use with the flex focus 1202 ultrasound system ... ideal for precise volume studies and guiding process and guiding prostate therapy ideal also for imaging the anterior and posterior compartments of the pelvic floor ... biplane imaging gives greater confidence in guiding therapy for a better orientation during needle placement expanded, sector allows complete visualization of the prostate ... perform quick reliable puncture and biopsy procedures with reusable needle guide ... unique fully immersible (capable of totally submerged in water without damage) transducer for easy sterilization ( a process that destroys or eliminates all forms of microbial life by physical or chemical methods) ... Reprocessing (a multistep process that includes cleaning, inspection, assembly, functional testing, disinfection, packaging, labeling, sterilization, and storage) ...Complete details and procedures can be found in Care and Cleaning ... Follow manufacturer’s instructions for use (MIFU) ...” During a review of the (MIFU) for the rectal ultrasound probe, titled “[Manufacturer] Care and Cleaning”, dated 2022, indicated, “Page 29, Levels of Reprocessing The level of reprocessing depends on the type of equipment and its use. The CDC (the nation’s leading science-based, data-driven, service organization that protects the public’s health) ... classify medical devices according to their use. For each classification, they specify the level of disinfection/sterilization processing that is required before use ... Device Classification: Semi-Critical; Use: Device contacts mucus membranes (for example, endocavity (anus (the external body orifice (opening) at the end of the digestive tract (bowel-intestine), the opposite end from the mouth); rectum (is at the end of your colon (large intestine) and on the other side of your anal canal); vagina( the elastic, muscular reproductive organ of the female genital tract); Required Processing: Immediate cleaning and high-level disinfection or sterilization ...” During an interview on 2/6/24 at 1:30 PM at H 1 with (Medical Director Pharmacy and Infection Control for [Name Healthcare System] (MDIC) and Director of Accreditation and Licensing (DAL) as scribe (wrote (for facility) questions asked and answers given during interview), the MDIC stated, he had oversight for (Healthcare System’s Name). He stated, the contractor would come in (on scheduled procedures dates) with (rectal) probe attached to the machine and told (facility) equipment was ready to go. MDIC stated, the rectal probe disinfection issue was discovered when (date not mentioned) a hospital that was part of the Healthcare System wanted to own/buy the equipment. A representative (name not mentioned) from (Contractor Name) came in and asked “why are you not doing high-level disinfection (HLD, a cleaning process which achieves elimination of all microorganisms in or on medical device, except for small number of bacterial spores)?” (Contractor Name) was not doing leak testing. MDIC stated, (Contractor Name) did not have a policy on disinfection. A new representative inquired why was HLD not being done. (Healthcare System Name) received (date not given) the report from a (Healthcare System Name) staff (identifier not mentioned). The MDIC further stated, “As soon as we learned, we stopped using (rectal probe). We set up the process- analyzed, identified the system gap related to the (Contractor Name) and set up a process, collected data, who was using the probes, the type of probes used. We developed a standard work for the specific probes ...” The MDIC stated, 450 patients from the whole Healthcare System were affected. The problem was presented to Biomed (biomedical department ensures medical devices and equipment are in good repair, functions effectively and are efficient.) as a whole package- machine (rectal probe connected into ultrasound system); went to Biomed as a piece of equipment, looked at it as a single package. They (Biomed) thought it (rectal probe) was no different than an external equipment, slipped under the radar because of the way the company presented it. MDIC stated, expectation was if it goes in the orifices, it needs HLD. We missed it - the need for HLD (information on duration not done not mentioned) for the rectal probes. During a review of facility’s document with 8 (eight) pages, not titled, printed 2/50 (sic)/2024, document indicated columned lists information with [ Facilities Group Name affiliated with (three) separately certified hospitals], Patient (s) Name, Medical Record Number, Date of Birth, Date of Procedure, Procedure, Address, Medical Doctor’s Name(s), (Page 8 indicated Total: 179 (total number of patients affected with rectal probe disinfection issue) ...” During an interview on 2/7/24 at 4 PM, at H 1, with DAL, DAL stated it was she who notified SA regarding the rectal probe disinfection issue. The 8 (eight) Pages document was the list of patients affected with rectal probe disinfection issue for [Facilities Group Name affiliated with (three) separately certified hospitals], Hospital (H)1, H 2, and H 3. Also, individuals(s) with authority and responsibilities for the conduct of the hospital and patient care (governing body) were the same for [(Healthcare System’s Name), [Facilities Group Name affiliated with (three) separately certified hospitals] H 1, H 2, and H 3; and all facility policies and procedures for H 1, H 2, and H 3 were (Healthcare System’s Name), [Facilities Group Name affiliated with (three) separately certified hospitals] policies and procedures. During a video call interview on 2/9/24 at 10:14 AM, at H 1 surveyors reviewed facility contract agreement packet titled, “Contract #SC14548, [(Name) Healthcare System], Sixth Amendment”, Renewed 4/30/2023, with Senior Director (Strategic Sourcing) (SDSS) for [(Name) Healthcare System] and Strategic Sourcing Manager for Contracting (SSMC), DAL was scribe. SDSS confirmed she signed contract agreement between “customer” [(Name) Healthcare System] and “contractor” [(Contractor Name) contractor who provided rectal probes)]. SDSS verified initial contract date was April 18, 2016, and expiring on 4/30/24. SSMC stated contract had auto renewal option. SDSS stated, for [(Name) Healthcare System], [Facilities Group Name in (Name) Area affiliated with (three) separately certified acute care hospitals] who use the same services, we [(Name) Healthcare System] employees responsible for contract agreement(s)] try to consolidate vendors [contractor(s)]. This one (contract agreement) started before I started with [(Name) Healthcare System]. SDSS confirmed contract applied to all [(Name) Healthcare System], [Facilities Group Name in (Name) Area affiliated with (three) separately certified acute care hospitals]. Surveyors reviewed with SDSS and SSMC contract agreement, “Page 1 of 20 ... AGREEMENT, I. SERVICES COVERED, 1. Services/ Products/Scope of Work” (Contractor) responsibilities and services to be provided for rented rectal probes (models not indicated), to (Healthcare System’s Name), ([Facilities Group Name] affiliated with (three) separately certified acute care hospitals in (Name) area] were not indicated/specified. SDSS stated, I think this contract has a gap. There should be additional amendment. SSMC stated, I’m not seeing amendments, looking for updates in the contracts, changes in the services ... Sixth amendment: current executed version, did not have vendor responsibilities, (in exhibit E, that should have been included in the current contract). SDSS stated, Basic HLD (high level disinfection) for scopes (general policy) - that policy requires that we perform HLD for items from vendors, checked by biomed. IC (Infection Control) department should be involved but this device (rented rectal probe) was not on the list of things that need HLD. It is the hospital’s responsibility to apply the IFU (instructions for use). It’s the directors in each department that is responsible for following the MIFU (manufacturer’s instructions for use). During an interview on 2/9/24 at 2:06 PM, at H 1, with Chief Operating Officer (COO) and DAL as scribe, COO stated, he was one of a group of individuals who had oversight (authority and responsibilities (governing body) for the conduct of the hospital and patient care) for [(Name) Healthcare System] [Facilities Group Name affiliated with (three) separately certified acute care hospitals] He confirmed each hospital had its own provider (Medicare) number. COO stated the rectal probe disinfection issue was not usual by definition - confirmed it was an unusual occurrence. The COO stated that before reporting (to CDPH), “we wanted to investigate to make sure what was happening. We had to determine whether patients were affected, which hospitals were using (the rectal probe), had to determine facts.” COO stated, with routine negotiation (of contracts) Board of Directors [(Name) Area Operating Board] were not involved in what was included in the contract. [(Name)Healthcare] “System” was responsible for contracts (agreement) with (Contractor) (effective 4/18/16, renewed 4/18/2021); but, he (COO) would have input. The COO stated, “The (Contractor) (vendor representative) is not responsible for the HLD, it’s the hospital’s job. Our policy indicates, in general, we’re supposed to do it (HLD). The HLD is our responsibility, we’re supposed to sterilize prior to use, to prevent transmission of infections. There was belief that we were doing what we were supposed to do in cleaning it (rectal probe), and equipment used for patients. HLD - that is our responsibility and we failed to do that.” The COO stated the directors of surgical services [DSS) - (Representatives for Quality Assurance are responsible for ensuring MIFU is followed. COO stated, regarding rectal probe disinfection issue not included in Quality Assurance Performance Improvement (QAPI) minutes for November to December 2023, January 2024 - “we have not gotten there yet, but it does not mean we did not discuss it.” During an interview on 2/14/24 at 10:10 a.m. with the Infection Prevention Manager (IPM), IPM stated the facility was part of a [hospital system] who had multiple hospitals in the state; in addition, the facility was part of a small group of three hospitals which shared a governing body and had a shared Infection Prevention Department. IPM stated she had oversight of three hospitals and there was a dedicated Infection Preventionist (IP) at each hospital. IPM further stated the three hospitals shared another IP who had oversight of surgical services for all three hospitals. IPM stated, in November 2023, she received a call from the Clinical Process Improvement Consultant (CPIC) for the facility’s hospital system regarding the facility’s use of rectal ultrasound probes. IPM stated, she was unaware if the facility used the rectal ultrasound probes, and she sent out an email to the Surgical Services Department at the facility to inquire about the use of the probes. IPM stated the hospital used the Spaulding Classification System (a nationally recognized infection control standard which is used to define the minimum level of disinfection required for a medical device) to determine how medical devices should be cleaned. IPM stated rectal ultrasound probes required High-level Disinfection (HLD- a cleaning process which achieves elimination of all microorganisms in or on a medical device, except for small numbers of bacterial spores) because the probe came in contact with mucous membranes (soft lining of body cavities and canals that lead to the outside of the body). IPM stated, she received an email response from the Surgical Services Manager who confirmed the rectal ultrasound probes were used in the operating room (OR) and reported the cleaning and disinfecting procedure did not include HLD. IPM stated she was unaware of the facility’s process for cleaning and disinfecting the probes until that date. IPM stated, at that time, the facility was instructed to stop the use of the probes as the cleaning and disinfection process was inadequate. During an interview on 2/14/24 at 2:42 p.m. with the Infection Prevention Registered Nurse (IP 1), IP 1 stated staff were expected to follow manufacturer’s IFU for all medical devices, for cleaning and disinfecting products. IP 1 further stated, it was his understanding that the rectal ultrasound probe manufacturer IFU allowed for low- level disinfection (a process that kills bacteria and some viruses on items that only come in contact with intact skin). IP 1 confirmed rectal ultrasound probes come in contact with mucus membranes and should be, at minimum, HLD according to the facility’s policy. During an interview on 2/15/24 at 9:30 a.m. with the Clinical Process Improvement Consultant (CPIC) for the facility’s hospital system, CPIC stated she worked for [hospital system name] which owned multiple hospitals in the state and the facility was a system hospital. CPIC stated, in November 2023, she received a concern from a staff member at a different hospital related to cleaning and disinfecting rectal ultrasound probes, so she reached out to all system hospitals to determine what their current process was. CPIC stated it was determined the facility was renting the rectal ultrasound probes from [vendor]. CPIC further stated, it was determined the facility was not cleaning and disinfecting the rectal ultrasound probes adequately. CPIC stated rectal ultrasound probes were considered semi-critical devices (any device that comes in contact with a mucus membrane) and required High Level Disinfection (HLD- a cleaning process which achieves elimination of all microorganisms in or on a medical device, except for small numbers of bacterial spores), at a minimum. CPIC confirmed the facility was not performing HLD on these devices. CPIC stated the facility was instructed to stop using the rectal ultrasound probes until an investigation was conducted. During an interview on 2/15/24 at 12 p.m. with the Director of Quality, Patient Safety, and Infection Control (DQI), the DQI stated in November 2023, she received a call from CPIC inquiring about the process the facility used to clean and disinfect rectal ultrasound probes. DQI stated the facility reported their process and were instructed to suspend using the probes because they were not HLD. During a review of the facility’s “Infection Prevention and Control Plan,” dated 3/16/23, the “Infection Prevention and Control Plan” indicated, a Risk Assessment was completed, and the facility identified one category of risk as “Infections Due to Disinfection or Sterilization Failures.” The facility did not identify patients undergoing procedures using the rectal ultrasound probe as a population at risk and did not identify HLD of the probes as an indicator. During a review of the facility’s policy and procedure (P&P) titled, “Infection Control Strategies for Handling Disinfection and Maintenance of Flexible Scopes, Rigid Endoscopes, Probes, Instruments,” dated 6/22/23, the P&P indicated, “The Spaulding Classification is used to define the minimum level of disinfection or sterilization required ... This classification system is based on the type of instrument used as well as the type of tissue exposed ... Semi-critical items= HLD required: devices contact mucous membranes or non-intact skin ... Endo cavity probes [a probe inserted into the human body] are heat sensitive, reusable Semi-critical devices that require HLD.” During a concurrent interview and record review on 2/15/24 at 3:45 p.m. with the Director of Accreditation and Licensing (DAL), the “List of [hospital] Patient Notification” was reviewed. DAL stated the facility identified a list of patients who had procedures using the rectal ultrasound probe and may have been affected by the failure to HLD the probes. DAL stated, the facility sent notification letters to all patients on the list. The list included a total of thirty-three patients. During a review of the facility (Healthcare System’s Name), [Facilities Group Name affiliated with (three) separately certified hospitals], document titled, “Infection Prevention and Control Plan,” dated 3/16/23, indicated, “Page 4 ... This document is a comprehensive evaluation, risk assessment. and prevention and control plan ... this process is completed annually. The risk assessment is completed at least annually and whenever significant changes occur ...The purpose of Infection Prevention and Control Department is to minimize the morbidity, mortality, and economic burden associated with healthcare associated infections (HAIs) through prevention and control endeavors in both patient and staff populations ... the most current CDC (Centers for Disease Control and Prevention, the nation’s leading science-based, data-driven, service organization that protects the public’s health.) NHSN (National Healthcare Safety Network-healthcare associated tracking system) and surveillance definitions and comparative database are utilized to evaluate patient outcomes ... Infection Prevention and Control is a facility wide patient safety component involving all departments. The Infection Preventionist, along with the Infection Prevention and Control Committee. Determines the specific focus of surveillance, education, and consultation effort on an ongoing basis ... Geographical Location, [Facilities Group Name affiliated with (three) separately certified hospitals], is a group of (Name ) area acute care facilities with 585 beds ... [Facilities Group Name affiliated with (three) separately certified hospitals], provides tertiary (high level of specialized care) care services for ... California ... Facilities Group Name affiliated with (three) separately certified hospitals], provides tertiary (high level of specialized care) care services for ... California ... Page 7 ... Authority and Responsibilities, The Governing Body and the [hospital] Infection Prevention and Control Committee members have the overall authority and responsibility for the Infection Prevention and Control Program...” 2. During a concurrent observation and interview with the Scrub Technician (ST 2) on 2/14/24 at 8:16 a.m. in the operating room (OR), ST 2 stated the surgical procedure had just finished and he was beginning the “pre-cleaning” process for the rectal ultrasound probe used in the procedure. During the pre-cleaning process, ST 2 was observed wiping the probe with disinfecting wipes beginning at the tip of the probe moving toward the top of the probe and ending at the cord which connects to the ultrasound monitor (in a dirty to clean direction). After wiping the probe, ST 2 placed the probe into a bin and stated, “Now it needs to dry for three minutes.” ST 2 left the probe in the bin for three minutes while performing other tasks. ST 2 then stated, it had been three minutes and he covered the bin with a red bag. The bin containing the probe was then sent in the elevator to the Sterile Processing Department (SPD). During a concurrent observation and interview with the Sterile Processing Technician (SPT 4) on 2/14/24 at 8:26 a.m. in the SPD, SPT 4 stated, he had just received the probe from the OR and was beginning the High-Level Disinfection process (a cleaning process which achieves elimination of all microorganisms in or on a medical device, except for small numbers of spores). SPT 4 stated a leak test (a process required to protect patients from infection that could result from leaks in the device and also protects the device from damage) was required for the probe to ensure there were no small holes in the probe. SPT 1 placed the leak tester on the end of the probe cord and pumped the pressure to a reading of 150 mm (millimeter of mercury- a measurement used to record pressure). Immediately after obtaining a pressure reading of 150 mm, SPT 1 stated, “It’s holding strong, so it passed the leak test.” SPT 4 did not monitor the pressure reading during the leak test for a specific amount of time. During an interview on 2/14/24 at 1:10 p.m. with the Surgical Services Manager (MSS 3), MSS 3 confirmed ST 1 should have wiped the rectal ultrasound probe with disinfecting wipes from the cord to the tip of the probe (clean to dirty direction). MSS 3 stated equipment should be wiped from clean to dirty to prevent cross contamination (spreading germs from dirty areas to clean areas). MSS 3 was unable to verbalize the IFU for the disinfecting wipes and stated, “We let it dry for three minutes to make sure it’s dried.” MSS was unaware the probe should have been dried with a cloth according to the Standard Work. During an interview on 2/14/24 at 2:42 p.m. with the Infection Prevention Registered Nurse (IP 1), IP 1 stated the IFU for the disinfecting wipes indicated a “wet time” of three minutes which meant the device should be maintained wet with the disinfecting product for three minutes and then dried with a cloth. During a concurrent interview and record review on 2/15/24 at 1:33 p.m. with the Sterile Processing Department Manager (SPDM), the manufacturer IFU for the rectal ultrasound probe was reviewed. SPDM confirmed, SPT 4 did not follow the IFU for leak testing the probe and should have waited 45 seconds to ensure the leak test was completed. During a review of the facility’s procedure for cleaning and disinfecting rectal ultrasound probes titled, “Standard Work- [manufacturer] Probes ‘model 888oe and 88848’ High Level Disinfection (HLD),” dated 1/31/24, the Standard Work indicated, “Pre-cleaning occurs at the point of use ... clean probe using a manufacturer approved disinfectant wipe ... thoroughly dry the probe with a soft cloth.” The Standard Work further indicated a leak test was required for rectal ultrasound probes with each cleaning process, “Perform leak test per manufacturers recommendation.” During a review of the manufacturer’s instructions for use (IFU) for the disinfecting wipes used on the rectal ultrasound probe, the IFU indicated, “Ultrasound Transducers and Probes ... use germicidal cloth to thoroughly wet the surface. Allow surface to remain wet three minutes ...” During a review of the manufacturer’s IFU for the rectal ultrasound probe, titled, “[manufacturer] Care and Cleaning,” issued 2022, the IFU indicated, “Leak Testing Procedure ... pump to increase the pressure to 150 mm ... once 150 is reached, observe the pressure for 45 seconds ... if the pressure is stable, place in the water tank ...” 3. During a concurrent observation and interview on 2/13/24, at 11:48 AM, of the Operating Room 5 (five), located on Level- A, North Tower building and interview with the Manager Surgical Services (MSS 3) and with the Quality Assurance Coordinator (QAC 3), there were three-cylinder tanks attached to the anesthesia cart machine. The first was an “oxygen tank (metal cylinders that store oxygen under pressure)”, the middle was a “compressed air (air that is pressurised to greater than atmospheric pressure)” tank, and the third was “nitrous oxide” (colorless, odorless anesthetic adjuvant) tank. The compressed air tank, which was the middle tank, had a light to dark brown discoloration around the tank. The MSS 3 wiped the tank with a dry paper towel and a light to dark discoloration around the tank came off which left a mark on the dry the paper towel. MSS 3 stated, it was “not dirt”, it was “rust” and it (compressed air tank) was not supposed to be in the OR. During an interview on 2/14/24, at 3:01 PM, with the Infection Preventionist (IP 1), the photo of the compressed air tank with light to dark brown discoloration around the tank observed in the OR was shown to him. The IP 1 stated, it should not be in the OR and staff should do hand hygiene (means cleaning the hands by using either handwashing [washing hands with soap and water], antiseptic hand wash, antiseptic hand rub [i.e. alcohol-based hand sanitizer including foam or gel]). Review of the facility’s Policy and Procedure titled, “Purchasing, Storing and Usage of Medical Gas Cylinders”, with the last revised date of 4/21/22 indicated, “xxx (name of the facility) shall provide a safe, systemic methods of ... storing, ... using medical compressed gas cylinders. ... PRECAUTIONS/COMPLICATIONS: ... B. Aged poorly maintained rusted or modified cylinders should not be used...””

    Rule A0951. Standard-level. From a complaint.

The one inspection in the last three years
Inspections on record
DateVisitWhat the record says
Feb 15, 2024Complaint inspection12 deficiencies cited

How do patients fare?

  • CMS’s overall for it is 3 of 5.
  • Of the measures behind its , CMS counts against the national value: mortality, 0 better and 0 worse of 4; safety of care, 1 better and 0 worse of 6; readmission, 0 better and 1 worse of 5.
  • Patients rate it 3 of 5 in CMS’s patient survey (602 surveys completed, Oct 1, 2024 to Sep 30, 2025): 70% rated it 9 or 10 out of 10, and 74% would definitely recommend it.
  • Infections, compared by CMS with the national benchmark (Oct 1, 2024 to Sep 30, 2025): central line bloodstream infections (CLABSI), no different than national benchmark; catheter urinary tract infections (CAUTI), better than the national benchmark; MRSA bloodstream infections, no different than national benchmark; C. diff infections, better than the national benchmark.
  • CMS’s patient safety composite for serious complications, PSI 90, Jul 1, 2022 to Jun 30, 2024: no different than the national value.
  • Deaths within 30 days, as CMS gives them (Jul 1, 2022 to Jun 30, 2025): heart failure 10%, pneumonia 15.1%, stroke 10.4%. CMS gives no comparison with the national rate for them in this release.
  • Readmissions within 30 days, as CMS gives them (Jul 1, 2023 to Jun 30, 2025): heart failure 22.1%, pneumonia 16.4%, COPD 19.6%, hip or knee replacement 5.5%. CMS gives no comparison with the national rate for them in this release.
  • After outpatient care, compared by CMS: unplanned hospital visits after outpatient surgery, no different than expected.
  • Emergency department patients spent a median of 160 minutes there before leaving (Oct 1, 2024 to Sep 30, 2025), and 2% left before being seen.
  • 75% of patients with severe sepsis or septic shock got the care CMS measures, SEP-1 (Oct 1, 2024 to Sep 30, 2025).
  • Medicare’s spending per patient here is 0.99 times the national median (Jan 1, 2024 to Dec 31, 2024).
Ratings and measures, as published
MeasureRating
Overall ratingCMS’s overall hospital quality star rating, 1 to 53 of 5
Patient survey ratingCMS star rating from its survey of the hospital’s patients (HCAHPS), 1 to 53 of 5

Is it certified, and in good standing?

  • Medicare-certified acute care hospital since Jul 1, 1966.
  • Ownership: voluntary non-profit - other.
  • It is accredited by The Joint Commission, whose surveys stand in for the state’s routine inspections.
  • Cited at in the last three years: it didn’t meet a whole condition of Medicare’s rules for hospitals.
  • It has an inpatient rehabilitation unit of 48 beds, which CMS lists apart as a rehabilitation facility.
  • Voluntary non-profit - Other.
Source:

CMS, Provider of Services File - Hospital & Non-Hospital Facilities. Released Oct 14, 2026. Updated quarterly.

CMS, Hospital General Information. Released Aug 13, 2026. Updated quarterly.

CMS, QCOR Hospital 2567 statements of deficiencies. Released Oct 20, 2026. Updated monthly.

Has it been penalized?

  • CMS doesn’t publish fines or other penalties for hospitals.
  • CMS cut its Medicare payments by 1% for fiscal year 2026 under the Hospital-Acquired Condition Reduction Program, which does so for the quarter of hospitals that fare worst on conditions patients get in hospital.
  • 12 deficiencies cited in the last three years came from inspections that included a complaint investigation.
Source:

CMS, Hospital-Acquired Condition (HAC) Reduction Program. Released Aug 13, 2026. Updated yearly.

CMS, Provider of Services File - Hospital & Non-Hospital Facilities. Released Oct 14, 2026. Updated quarterly.

CMS, QCOR Hospital 2567 statements of deficiencies. Released Oct 20, 2026. Updated monthly.

On record, newest first
DateWhatDetail
Medicare payment reduction (HAC Reduction Program)Fiscal year 2026: 1% of Medicare payments

What do patients say about their care?

  • CMS doesn’t publish staffing levels for hospitals.
  • In CMS’s patient survey, patients rate how well its nurses communicated 2 of 5.
  • 82% of its health care workers got a flu shot (Oct 1, 2024 to Mar 31, 2025).
Source:

CMS, Patient survey (HCAHPS) - Hospital and Timely and Effective Care - Hospital. Released Aug 13, 2026. Updated quarterly.

Who owns it?

  • Sutter Health owns 100% directly since Jul 31, 2009.
  • 18 owners or officers are people: Yvonne Richardson (corporate director); Todd C Smith (corporate director); Gregory Brown (corporate director); Jill M Kacher Cobb (corporate director); Arnold Schaffer (corporate director); Theodore Deikel (corporate director); Janet Garufis (corporate director); Rita Ophelia Kwan-Feinberg (corporate director); Susan Mccabe (corporate director); Juli Maxworthy (corporate director); Heidi J Schmidt (corporate director); Thomas Briody (corporate director); William L Brunetti (corporate director); Jeffrey T Strawn (corporate director); Yumi Nakagawa (corporate director); Jonathan Ma (corporate officer); Jonathan Ma (managing employee (on the payroll)); Aditi H Patel (corporate director).
  • CMS’s Provider of Services file records 1 change of ownership, the latest on Jul 30, 1998.
  • No private-equity firm among the owners CMS lists.
  • No real-estate investment trust among the owners CMS lists.
Source:

CMS, Hospital All Owners and Hospital Enrollments. Released Sep 29, 2026. Updated monthly.

CMS, Provider of Services File - Hospital & Non-Hospital Facilities. Released Oct 14, 2026. Updated quarterly.

Organisations CMS lists
OrganisationRoleShareSince
Sutter HealthOwns 5% or more directly100%Jul 31, 2009

How does it compare nearby?

  • Of the 13 hospitals CMS lists in San Francisco County, 10 have an overall star rating from CMS: 5 rated 4 of 5, 3 rated 3 of 5, 2 rated 2 of 5.
  • CMS rates this one 3 of 5.
Source:

CMS, Hospital General Information. Released Aug 13, 2026. Updated quarterly.

What the record doesn’t say

  • CMS doesn’t publish fines or other penalties for hospitals, so none are shown. The one payment cut CMS publishes for each hospital, under its Hospital-Acquired Condition Reduction Program, is shown where it applies.
  • Only complaints that led to a citation appear; complaints that didn’t aren’t published.
  • Most hospitals are accredited by a private organisation (The Joint Commission, DNV and others) whose routine inspections stand in for the state’s; those reports aren’t public, and QCOR holds only the state’s surveys: no inspection on record here doesn’t mean none took place.
  • QCOR says its hospital inspection data are complete only through September 17, 2026, while it moves to a new system.
  • CMS doesn’t publish staffing levels for hospitals.
  • In its September 2026 release CMS gives no comparison with the national rate for death and readmission rates, though it gives the rates.

Sources

If you believe something here is wrong, a correction starts with the agency whose record this copies: CMS. CMS’s own record is on Care Compare. If Hearth Record copied something wrongly, it will fix it and log the correction publicly, with its date: how corrections work.

Source:

This copy of the record was made on Nov 5, 2026.

From the hospital

The public record above comes first. Anything the hospital adds will appear here, below it, and say who wrote it.

Replies

None. Replies aren’t open yet. When they open, the hospital will be able to answer any finding for free, and the reply will show beside that finding, unedited and dated.

Paid listing

None. Paid listings aren’t open yet. When they open, anything paid for will say “Paid by the hospital”, and paying will never change a finding, a rating or the order of results.

How to read a record

Four things every record does, shown on an example record made up for this guide.

An example record, made up for this guide

An example nursing home

Made up for this guide: no real place is shown

Not fully inspected in over two years (CMS flag)

11 health citations at the latest inspection cycle

The state average is 14.3.

Source:

CMS, State and US Averages and Health Deficiencies. Released Oct 28, 2026. Updated monthly.

From the homeNone yet. Replies and paid listings aren’t open, and when they open they will sit here, below the record.

1 of 4

Every fact names its source.

Who published it, when, and how often it changes sit beside each fact, with a link to the agency’s own file.

Sign in

A free account keeps your watch list, shortlists, comparisons and saved searches on every device, and can email you when something you watch changes. Browsing never needs one.