Via Health Partners - Cleveland
A hospice in Shelby, North Carolina 28150
951 Wendover Heights Drive, Shelby, North Carolina 28150. (704) 487-4677.
Watch and the shortlist are kept with a free account, on every device. Your watch list. CMS’s own record is on Care Compare.
The short answer
Record last released by CMS on Oct 23, 2026.
- 16 deficiencies cited in the last three years
- 4of 5 family caregiver rating
- 10of 10 CMS’s Hospice Care Index
Each figure’s source sits beside it, in its section below.
What these words mean4
- Star ratings
- CMS rates some kinds of place from 1 to 5 stars, more stars meaning better on CMS’s own measures for that kind: for a nursing home, its health inspections, staffing and quality measures. A rating is CMS’s summary of those measures; it doesn’t promise good care. Source: CMS, Care Compare and the Five-Star Quality Rating System.
- Inspection (survey)
- A visit by state inspectors, often unannounced, who check a place against the rules it must meet. For nursing homes and other places Medicare pays, CMS calls these visits surveys: a standard survey of a nursing home comes at least every 15 months, and a complaint survey whenever a complaint calls for one. Source: CMS; 42 CFR 488.308.
- Deficiency, citation, violation
- What inspectors write up when a place didn’t meet a rule: the rule, what they saw, and when. CMS calls it a deficiency; states may say citation or violation. It is the inspectors’ finding, not a court’s, and the place is usually asked for a plan to correct it. Source: CMS, statement of deficiencies (Form CMS-2567); each state’s licensing agency.
- Condition-level deficiency
- For hospices, home health agencies, hospitals and dialysis facilities, CMS writes deficiencies at two levels. Standard is the usual one; condition-level is the more serious, when a problem is serious enough that the provider doesn’t meet a whole condition of taking part in Medicare. Source: CMS, State Operations Manual.
What did inspectors find?
16 deficiencies cited in the last three years
The middle of the 5 hospices serving ZIP code 28150 had 9.
The last inspection on record was on May 19, 2026: a follow-up inspection by the Accreditation Commission for Health Care.
1 deficiency at condition level, the more serious of CMS’s two levels
CMS, QCOR hospice inspection reports. Released Oct 23, 2026. Updated quarterly.
CMS, Hospice ZIP Data. Released Aug 26, 2026. Updated quarterly.
When those deficiencies happened
16 deficiencies in 2 months of the last 36. Last cited Apr 2026. Most serious: Condition-level. The last 3 years, to Oct 27, 2026.
| Jan | Feb | Mar | Apr | May | Jun | Jul | Aug | Sep | Oct | Nov | Dec | |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 2023 | Nov | Dec | ||||||||||
| 2024 | Jan | Feb | Mar | Apr | May | Jun | Jul | Aug | Sep | Oct | Nov | Dec |
| 2025 | Jan | Feb | Mar | Apr | May | Jun | Jul | Aug | Sep | Oct | Nov | Dec |
| 2026 | Jan | Feb | Mar | Apr | May | Jun | Jul | Aug | Sep | Oct |
Hover or focus a month to read it.
Hearth Record drew this from the dates and levels in the source’s own records.
Each deficiency, as cited
Rule titles as CMS’s inspectors cite them, set in sentence case.
CMS, QCOR hospice inspection reports. Released Oct 23, 2026. Updated quarterly.
Apr 10, 2026: reaccreditation inspection by the Accreditation Commission for Health Care15 deficiencies
-
N/a (42 CFR 418.110)
“Condition of Participation: Hospices that Provide Inpatient Care Directly.”
-
Content of comprehensive assessment (42 CFR 418.54(c)(4))
“Upon patient record review, 5 of 29 (Patients #2,10,12,19,24) did not have evidence in the patient record that the comprehensive assessment takes into consideration the imminence of death.”
-
Content of comprehensive assessment (42 CFR 418.54(c)(6))
The inspectors’ words, 135 words
“Upon patient record review, 1 of 29 (Patient #2) did not have evidence in the patient record that a review was completed of all prescription and non-prescription medications, including herbal remedies that could affect drug therapy. This review includes, but is not limited to: • Effectiveness of drug therapy • Drug side effects • Actual or potential drug interactions • Duplicate drug therapy • Drug therapy currently associated with laboratory monitoring Patient #2: During medication reconciliation at visit the following findings: 1. Hospice med profile indicated Nitrostat 0.4 mg 1 tab every 5 minutes NTE 3 tabs / ALF medication profile did not include this medication 2. ALF included Hydrocortisone 2.5% (rt arm), hyoscyamine 0.125 mg every 6 hours PRN, Morphine 5mg every 6 hours PRN. / Hospice medication profile did not include these medications.”
-
Content of plan of care (42 CFR 418.56(c)(4))
“Upon patient record review, 1 of 29 (Patient #2) did not have evidence the plan of care must include all services necessary for the palliation and management of the terminal illness and related conditions, including medications and treatments. Patient #2: Patient has a malnutrition diagnosis and family provides an Ensure supplement. The hospice was unaware of the supplement being given. There were no orders for Ensure in the hospice record.”
-
Content of plan of care (42 CFR 418.56(c)(5))
The inspectors’ words, 125 words
“Upon patient record review, 5 of 29 (Patients #2,11,15,21,22) did not have evidence the plan of care must include all services necessary for the palliation and management of the terminal illness and related conditions, including equipment and supply needs. Patient 2: This patient had an APP Mattress. This were not included on the Plan of Care. Patient #11:The record reflected that this patient had an IV Pole. This was not included on the Plan of Care. Patient 15: The record reflected that this patient had oxygen and a walker. These were not included on the Plan of Care. Patients #21 and 22: The record reflected that this patient had an APP mattress and a nebulizer machine. These were not included on the Plan of Care.”
-
Authentication (42 CFR 418.104(b))
The inspectors’ words, 106 words
“Upon patient client record review, 1 of 29 (Patient #11) did not have evidence that all entries are legible, clear, complete, and appropriately authenticated and dated in accordance with the organizations policies and procedures and currently accepted standards of practice. Electronic signatures are acceptable as long the hospice is following appropriate safeguards to prevent unauthorized access to the patient records. Patient #11: The Initial Nursing Comprehensive contained the answer “No” for patient receiving nutritional supplement. The next line indicated on the comprehensive patient receives 5-6 boluses per day. The Initial Plan of Care indicated this patient receives Nutren 0.07Kcal/mL. The Nursing Initial Comprehensive was not consistent.”
-
N/a (42 CFR 418.110(c)(2))
The inspectors’ words, 131 words
“Upon observation, there was no evidence the hospice inpatient facility tests their power systems in accordance with NFPA 99 and NFPA 110 including the maintenance and testing of alternate power sources and transfer inspection and testing and maintenance and testing of circuitry. On 04/09/26 during the tour of the TESTA building, it was observed that the emergency stop button for the generator was located inside the outdoor metal enclosure rather than in an external, readily accessible location. Staff confirmed that there was no remote stop station positioned outside the generator enclosure, which is not in compliance with NFPA 110 (2010 Edition), Section 5.6.5.6 requirements that all emergency generator sets have a remote manual stop station located outside the housing of the prime mover, where it is readily accessible and appropriately identified.”
-
N/a (42 CFR 418.110(d))
The inspectors’ words, 216 words
“Upon observation, there is no evidence the corridor walls and doors of a facility is provided consistent with the 2012 editions of the LSC of the National Fire Protection Association and NFPA 99. Hospices are exempt from chapter 19.3.6.3.5 “exception number 1 and 2 and 19.3.6.3.6 number 2”. If recommended by state survey agency, CMS may waive for periods deemed appropriate, specific provisions of the LSC which, if rigidly applied, would result in unreasonable hardship to the hospice, but only if the waiver would not adversely affect the health and safety of patients. The provisions of the adopted edition of the Life Safety Code do not apply in a State if CMS finds that a fire and safety code imposed by State law adequately protects patients in hospices. Existing Construction On 04/07/26, during a tour of the Wendover building, it was observed that the smoke compartment wall located above the double doors in the laundry hallway contained one unsealed penetration. Specifically, an insulated water pipe penetrated the gypsum board wall without an approved firestop system to maintain the integrity of the smoke barrier in accordance with NFPA 101 (2012 Edition), Section 19.3.6.1 Corridor Separation. This condition compromised the continuity of the smoke barrier by allowing a potential path for the transfer of smoke between smoke compartments.”
-
N/a (42 CFR 418.110(d))
The inspectors’ words, 239 words
“Upon observation, there is no evidence the smoke compartmentation and control of a facility is provided consistent with the 2012 editions of the LSC of the National Fire Protection Association and NFPA 99. The provisions of the adopted edition of the Life Safety Code do not apply in a State if CMS finds that a fire and safety code imposed by State law adequately protects patients in hospices. Existing Construction Based on observations, the facility failed to maintain the fire-resistance rating of fire-rated barriers by ensuring penetrations were protected with an approved firestop system in accordance with NFPA 101 Life Safety Code, Section 19.3.7.6. which could allow the passage of smoke and fire through fire-rated assemblies, affecting multiple areas within the buildings. On 04/07/26, during a tour of the Wendover building, in the electrical room, three pipe penetrations through a 2-hour fire-rated assembly were observed without an approved firestop system. The penetrations lacked firestop material, compromising the fire-resistance rating of the barrier. On 04/09/26, during a tour of the TESTA building, the following conditions were observed that lacked firestop material, compromising the fire-resistance rating of the barrier, that included: 1. In the electrical room, a pipe penetration through the ceiling was sealed with foam that was not identified as an approved firestop material. 2. In the sprinkler room, an unsealed wall penetration was observed that contained flexible conduit with wiring, and was not protected with an approved firestop system.”
-
N/a (42 CFR 418.110(d))
The inspectors’ words, 168 words
“Upon observation, there was no evidence the building service equipment of a facility is provided consistent with the 2012 editions of the LSC of the National Fire Protection Association and NFPA 99. The provisions of the adopted edition of the Life Safety Code do not apply in a State if CMS finds that a fire and safety code imposed by State law adequately protects patients in hospices. Existing Construction During observations, the facility failed to maintain ventilation systems in accordance with NFPA 99 Health Care Facilities Code, Chapter 9, as well as NFPA 101 Life Safety Code, Sections 19.5.2.1 and 9.2, which could contribute to the spread of fire and smoke or indicate compromised system integrity, affecting the safety of patients, staff, and visitors. On 04/09/2026, during a tour of the TESTA location, it was observed that the air return located in the ceiling of the soiled linen room was heavily loaded with lint and debris. The accumulation of lint created a combustible condition within the ventilation system.”
-
N/a (42 CFR 418.110(d))
The inspectors’ words, 140 words
“Upon observation, there was no evidence the electrical of a facility is provided consistent with the 2012 editions of the LSC of the National Fire Protection Association and NFPA 99. The provisions of the adopted edition of the Life Safety Code do not apply in a State if CMS finds that a fire and safety code imposed by State law adequately protects patients in hospices. New and existing Construction On 04/07/26 during a tour of the Wendover building, in a mechanical space, the air handling unit (AHU) shutdown relay junction box was observed with the cover missing, leaving electrical wiring exposed which was not in compliance with NFPA 101 (2012 Edition), Section 9.1.2, which references compliance with NFPA 70, (NEC) 314.25, requires that all junction boxes be provided with approved covers to protect wiring and prevent exposure to physical damage.”
-
N/a (42 CFR 418.110(d))
The inspectors’ words, 307 words
“Upon observation, there was no evidence the exits and egress of a facility is provided consistent with the 2012 editions of the LSC of the National Fire Protection Association and NFPA 99. The provisions of the adopted edition of the Life Safety Code do not apply in a State if CMS finds that a fire and safety code imposed by State law adequately protects patients in hospices. Existing Construction On 04/07/26 during a tour of the Wendover building, it was observed that: 1. Two vital sign carts were positioned in the corridor in front of the nurses’ station. The carts were connected to electrical outlets for charging, were not in use at the time of observation, and remained unattended for greater than 30 minutes which was not in accordance with NFPA 101 (2012 Edition), Section 19.2.3 requirements that corridors remain clear and unobstructed to ensure safe and immediate use in the event of an emergency and Section 7.1.10 requires that the means of egress be continuously maintained free of all obstructions or impediments. 2. Patient sleeping rooms with glass doors leading to a patio enclosed by a brick wall were not provided with “NO EXIT” signage. These doors could be mistaken for an exit; however, they did not discharge to a public way which could mislead occupants during an emergency, delaying evacuation and affecting the safety of patients, staff and visitors, and was not in compliance with NFPA 101 (2012 Edition), Section 19.2.10, which references Section 7.10.8.3.2, requiring doors or passageways that could be mistaken for exits to be marked with a “NO EXIT” sign. The sign must display the words “NO EXIT” in letters 2 inches high with a stroke width of 3/8 inch, and the word “EXIT” in letters 1 inch high placed below the word “NO,” unless the sign is an approved existing sign.”
-
N/a (42 CFR 418.110(d))
The inspectors’ words, 309 words
“Upon observation, there was no evidence the fire alarm systems of a facility are provided consistent with the 2012 editions of the LSC of the National Fire Protection Association and NFPA 99. The provisions of the adopted edition of the Life Safety Code do not apply in a State if CMS finds that a fire and safety code imposed by State law adequately protects patients in hospices. Existing Construction On 04/07/26 during a tour of the Wendover building, the following deficiencies were observed: 1. Inside the main entrance door, on the left side while facing the door opening, a wheelchair was positioned directly in front of a fire alarm pull station, obstructing access to the device and was not in compliance with NFPA 101 Life Safety Code, Section 19.3.4.1, which requires fire alarm systems to be installed and maintained in accordance with NFPA 72 National Fire Alarm and Signaling Code. NFPA 72 requires initiating devices to be accessible and unobstructed. 2. In patient rooms 5 and 15, bathroom emergency call system pull cords were observed to terminate greater than 6 inches above the finished floor, reducing accessibility for patients requiring assistance, and was not in compliances with NFPA 101 Life Safety Code, Section 19.3.4 which requires patient safety features, including nurse call systems, to be maintained and ensure accessibility and proper operation. 3. The Fire Alarm Control Panel (FACP) cabinet contained exposed wiring and not in compliance with NFPA 72 National Fire Alarm and Signaling Code Sections 10.5.1 and 10.5.5 which require equipment to be installed in a neat and workmanlike manner and protected from physical damage. Additionally, NFPA 99 Health Care Facilities Code Section 6.3.2.2.8 requires electrical components of essential systems to be installed safely, and NFPA 101 Life Safety Code Section 9.6.1.3 requires fire alarm systems to be installed, tested, and maintained in accordance with NFPA 72”
-
N/a (42 CFR 418.110(d))
The inspectors’ words, 188 words
“Upon observation, there was no evidence the hazardous areas of a facility are provided consistent with the 2012 editions of the LSC of the National Fire Protection Association and NFPA 99. The provisions of the adopted edition of the Life Safety Code do not apply in a State if CMS finds that a fire and safety code imposed by State law adequately protects patients in hospices. Existing Construction On 04/09/26, during a tour of the TESTA building, it was observed that the kitchen, identified as a hazardous area, had three unsealed penetrations in the ceiling. Specifically, one sprinkler head was missing an escutcheon trim plate, and two additional openings were present in the ceiling where recent work had been completed on fluorescent light fixtures which demonstrated a failure to maintain the the fire-resistive integrity of a hazardous area enclosure and was not in compliance with with NFPA 101 (2012 Edition), Section 19.3.2.1, which requires hazardous areas to be protected by fire barriers constructed to resist the passage of smoke and fire, and Section 8.5.6.2, which requires penetrations to be protected to maintain the fire-resistance rating of the barrier.”
-
N/a (42 CFR 418.110(m)(2))
“Upon observation, there was no evidence the hospice provided follow-up for all temperature variations out of range with mercury-in-glass thermometer that included documented follow-up within a described time frame as defined in policies and procedures. Nourishment Refrigerator: • 12/25/25 - 12/29 = 42°; no documented follow-up • 1/13 & 1/14/26 = 42°; no follow-up Family Kitchen Refrigerator: • 2/27/26 = 32°; no follow-up • 3/17 & 3/18/26 = 32°; no follow-up”
Aug 12, 2025: complaint inspection by the Accreditation Commission for Health Care1 deficiency
-
Program activities (42 CFR 418.58(c)(2))
The inspectors’ words, 97 words
“Upon observation, there was no evidence the hospice investigates all adverse events, incidents, accidents, variances or unusual occurrences that involve patient care and develops a plan of correction to prevent the same or similar event from occurring again. Patient#3: The record indicates on 6/14/25 patient passed away. The SN was not allowed to attend the death per family request. Agency documented family called ambulance and paramedic pronounced patient in the home. Family called the funeral home. Agency policy states “incident report should be prepared for all occurrences that are not consistent with the ordinary and customary operations”.”
All 3 inspections in the last three years
| Date | Visit | What the record says |
|---|---|---|
| May 19, 2026 | Follow-up inspection by the Accreditation Commission for Health Care | No deficiencies cited |
| Apr 10, 2026 | Reaccreditation inspection by the Accreditation Commission for Health Care | 15 deficiencies cited |
| Aug 12, 2025 | Complaint inspection by the Accreditation Commission for Health Care | 1 deficiency cited |
Is it certified?
- Medicare-certified hospice since Nov 10, 1987.
- Ownership: non-profit.
- Cited at For hospices, home health agencies, hospitals and dialysis facilities, CMS writes deficiencies at two levels. Standard is the usual one; condition-level is the more serious, when a problem is serious enough that the provider doesn’t meet a whole condition of taking part in Medicare. Source: CMS, State Operations Manual. in the last three years: it didn’t meet a whole condition of Medicare’s rules.
CMS, Hospice General Information. Released Aug 26, 2026. Updated quarterly.
CMS, QCOR hospice inspection reports. Released Oct 23, 2026. Updated quarterly.
Has anything been proven against it?
- CMS doesn’t publish fines or other penalties for hospices, so none are shown.
- 1 deficiency cited in the last three years came from an inspection that included a complaint investigation.
CMS, QCOR hospice inspection reports. Released Oct 23, 2026. Updated quarterly.
Who does the caring?
- From Medicare claims (Jan 1, 2023 to Dec 31, 2024): 14.6 nurse care minutes per routine home care day, 10.3% of skilled nursing minutes at weekends and a visit near death for 95.4% of patients who died.
- Where its patients were cared for (Jan 1, 2024 to Dec 31, 2024): 62% at home, 13% in assisted living, 19% in a nursing facility, 1% in a hospital, 3% in an inpatient hospice, 3% elsewhere.
CMS, Hospice Provider Data. Released Aug 26, 2026. Updated quarterly.
| Measure | This provider |
|---|---|
| Nurse care minutes per routine home care day | 14.6 min |
| Skilled nursing minutes at weekends | 10.3% |
| Visits near death | 95.4% of patients who died |
Who owns it?
- 3 owners or officers are people: Peter A Brunnick (corporate officer); Julie Ann Vibbert (managing employee (on the payroll)); Bridget Ilka Hiller (managing employee (on the payroll)).
- No private-equity firm among the owners CMS lists.
- No real-estate investment trust among the owners CMS lists.
CMS, Hospice All Owners and Hospice Enrollments. Released Sep 29, 2026. Updated quarterly.
What do families say?
- Family caregivers rate it 4 of 5 in CMS’s survey (Oct 1, 2023 to Sep 30, 2025): 86% rated it 9 or 10 out of 10, and 91% would definitely recommend it.
- CMS’s Hospice Care Index: 10 of 10 (Jan 1, 2023 to Dec 31, 2024).
- 98.19% of patients were assessed on all seven of CMS’s measures at the start of care (Oct 1, 2024 to Sep 30, 2025); 77.5% had visits from a nurse or social worker on at least 2 of their last 3 days (Jan 1, 2023 to Dec 31, 2024).
CMS, CAHPS Hospice Survey and Hospice Provider Data. Released Aug 26, 2026. Updated quarterly.
| Measure | Rating |
|---|---|
| Family caregiver survey ratingCMS star rating from its survey of patients’ family caregivers, 1 to 5 | 4 of 5 |
| Hospice Care IndexCMS’s Hospice Care Index, 0 to 10 (higher is better): a point for each of ten measures from Medicare claims on which the hospice meets CMS’s threshold | 10 of 10 |
How does it compare nearby?
- Of the 5 hospices CMS’s data show serving patients in ZIP code 28150, where this hospice’s office is, the middle number of deficiencies cited in the last three years was 9; this one had 16.
CMS, Hospice ZIP Data. Released Aug 26, 2026. Updated quarterly.
CMS, QCOR hospice inspection reports. Released Oct 23, 2026. Updated quarterly.
| Place | Deficiencies, 3 years |
|---|---|
| Via Health Partners - Cleveland This hospice | 16 |
| Hospice & Palliative Care Charlotte Region | 9 |
| Hospice of the Carolina Foothills | 9 |
| Carolina Caring | 0 |
| Gentiva | 18 |
What the record doesn’t say
- CMS doesn’t publish fines or other penalties for hospices, so none are shown.
- Only complaints that led to a citation appear; complaints that didn’t aren’t published.
- CMS ended its Special Focus Program for hospices with serious problems on Feb 14, 2025, so no hospice is marked as one.
- Hospice quality measures have a gap from October 2025: CMS replaced its patient assessment then, and public results from the new one (HOPE) are expected around November 2027.
Sources
-
Centers for Medicare & Medicaid Services, Hospice General Information (yc9t-dgbk).
Released Aug 26, 2026 and checked Oct 27, 2026. Updated quarterly. Public domain (U.S. Government work).
-
Centers for Medicare & Medicaid Services, Hospice Provider Data (252m-zfp9).
Released Aug 26, 2026 and checked Oct 27, 2026. Updated quarterly. Public domain (U.S. Government work).
-
Centers for Medicare & Medicaid Services, CAHPS Hospice Survey (gxki-hrr8).
Released Aug 26, 2026 and checked Oct 27, 2026. Updated quarterly. Public domain (U.S. Government work).
-
Centers for Medicare & Medicaid Services, QCOR hospice inspection reports (Hospice Survey Reports - Oct 2021 through Sep 2026.xlsx).
Released Oct 23, 2026 and checked Oct 27, 2026. Updated quarterly. Public domain (U.S. Government work).
-
Centers for Medicare & Medicaid Services, Hospice All Owners (e983965e-1603-4cb8-82b5-c40090e380d1).
Released Sep 29, 2026 and checked Oct 27, 2026. Updated quarterly. Public domain (U.S. Government work).
-
Centers for Medicare & Medicaid Services, Hospice Enrollments (25704213-e833-4b8b-9dbc-58dd17149209).
Released Sep 29, 2026 and checked Oct 27, 2026. Updated quarterly. Public domain (U.S. Government work).
-
Centers for Medicare & Medicaid Services, Hospice ZIP Data (95rg-2usp).
Released Aug 26, 2026 and checked Oct 27, 2026. Updated quarterly. Public domain (U.S. Government work).
If you believe something here is wrong, a correction starts with the agency whose record this copies: CMS. CMS’s own record is on Care Compare. If Hearth Record copied something wrongly, it will fix it and log the correction publicly, with its date: how corrections work.
This copy of the record was made on Oct 27, 2026.
From the hospice
The public record above comes first. Anything the hospice adds will appear here, below it, and say who wrote it.
Replies
None. Replies aren’t open yet. When they open, the hospice will be able to answer any finding for free, and the reply will show beside that finding, unedited and dated.
Paid listing
None. Paid listings aren’t open yet. When they open, anything paid for will say “Paid by the hospice”, and paying will never change a finding, a rating or the order of results.