Hearth Record

Fresenius Medical Care Hawks Nest

A dialysis facility in Montgomery, West Virginia 25136

506 3rd Avenue, Montgomery, West Virginia 25136. (304) 442-5711.

CMS’s own record, on Care Compare

Watch and the shortlist are kept with a free account, on every device. Your watch list. CMS’s own record is on Care Compare.

The short answer

Record last released by CMS on Oct 28, 2026.

The last 24 months 2 deficiencies in 1 month of the last 36. Last cited Apr 2024. Most serious: Standard-level. Every month

Each figure’s source sits beside it, in its section below.

What these words mean3
Star ratings
CMS rates some kinds of place from 1 to 5 stars, more stars meaning better on CMS’s own measures for that kind: for a nursing home, its health inspections, staffing and quality measures. A rating is CMS’s summary of those measures; it doesn’t promise good care. Source: CMS, Care Compare and the Five-Star Quality Rating System.
Inspection (survey)
A visit by state inspectors, often unannounced, who check a place against the rules it must meet. For nursing homes and other places Medicare pays, CMS calls these visits surveys: a standard survey of a nursing home comes at least every 15 months, and a complaint survey whenever a complaint calls for one. Source: CMS; 42 CFR 488.308.
Deficiency, citation, violation
What inspectors write up when a place didn’t meet a rule: the rule, what they saw, and when. CMS calls it a deficiency; states may say citation or violation. It is the inspectors’ finding, not a court’s, and the place is usually asked for a plan to correct it. Source: CMS, statement of deficiencies (Form CMS-2567); each state’s licensing agency.

What did inspectors find?

The last inspection on record was on Dec 4, 2024: a standard inspection.

2 deficiencies cited in the last three years.

Source:

CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.

When those deficiencies happened

2 deficiencies in 1 month of the last 36. Last cited Apr 2024. Most serious: Standard-level. The last 3 years, to Oct 30, 2026.

2 deficiencies by month over the last 3 years. Each cell is one month.
JanFebMarAprMayJunJulAugSepOctNovDec
2023 NovDec
2024 JanFebMarAprMayJunJulAugSepOctNovDec
2025 JanFebMarAprMayJunJulAugSepOctNovDec
2026 JanFebMarAprMayJunJulAugSepOct

Hover or focus a month to read it.

No visit on record Visited, nothing cited A stronger orange is more serious, on its source’s own levels, read onto four bands: from the least serious it publishes to the most
Source:

Hearth Record drew this from the dates and levels in the source’s own records.

Each deficiency, as cited

Rule titles as CMS’s inspectors cite them, set in sentence case.

Source:

CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.

Apr 10, 2024: standard inspection2 deficiencies
  • Ic - Oversight: Monitor Activities & Implement Policies

    The inspectors’ words, 535 words

    “IC-O-SIGHT-MONITOR ACTIVITY/IMPLEMENT P&P CFR(s): 494.30(b)(1) The facility must- (1) Monitor and implement biohazard and infection control policies and activities within the dialysis unit; This Standard is not met as evidenced by: 38282 Based on observation, documentation review, and staff interview, the facility failed to ensure the proper procedures were utilized during a pre-treatment lab draw in order to prevent infection for one (1) of one (1) patient (Patient #6) observed having bloodwork drawn from a CVC [central venous catheter]. This failure has the potential to affect all patients receiving lab draws at the facility. Cross Reference: 494.30 (a)(4) Standard: Procedures for Infection Control Findings are as follows: A review of the policy, titled “Drawing Blood Work Pre-Treatment from an AVF/AVG [arteriovenous fistula/arteriovenous graft] or Catheter;” dated 05/02/22; stated, in part, “All bloodwork will be obtained following the same processes to ensure consistency and accuracy of the results.” The procedure for drawing the bloodwork from the CVC was reviewed but did not include re-instilling the blood waste. A review of the policy, titled “Hand Hygiene” dated 11/06/23; stated, in part, “Hands will be decontaminated using alcohol-based hand rub or by washing hands with antimicrobial soap and water. When: ... Entering and leaving the treatment area ... After contact with other objects within the patient station or treatment space.” An observation was conducted on 04/08/24 starting at 12:15 p.m. of Patient #6 at Station #1. Employee #1 was accessing the venous catheter for a pre-treatment lab draw prior to the initiation of dialysis. Employee #1 sanitized their hands, donned gloves, placed a barrier under the CVC, and flushed the port with ten milliliters (10 ml) of saline. Employee #1 stated: “Oh! I need to draw labs.” Then Employee #1, without removing the gloves, left station #1 and went to the nurses station, located diagonal to station #1, and was handed a 10 cc [cubic centimeter] syringe per request. Employee #1 returned to station #1, and without removing her gloves and sanitizing her hands, pulled 10 ml of “waste” blood into the syringe. Employee #1 laid the uncapped syringe of blood on the barrier, placed the vacutainer on the port and obtained the sample for testing, and picked up the syringe of blood and reinstalled it into the catheter. Dialysis was then initiated. An interview was conducted on 04/09/24 at 9:05 a.m. with Employee #2, who confirmed that at no time was “waste” blood to be re-instilled because of the increased risk of infection. Employee #2 stated that an adverse event report was going to be placed and staff required retraining. An interview on 04/10/24 at 11:05 a.m. with Employee #1 regarding the pre-treatment lab draw on Patient #6. Employee #1 stated they had drawn the waste blood because of accidentally instilling saline into the line prior to drawing the labs. Employee #1 then confirmed that the waste blood was returned to the patient, and that they now know it should never be returned, as it would increase the risk of infection. Employee #1 confirmed gloves were to be changed and hands sanitized anytime you leave a patient station and return; and that they had left the station to retrieve a syringe and returned without changing their gloves.”

    Rule V0142. Standard-level.

  • Md Resp - Ensure All Adhere To P&P

    The inspectors’ words, 464 words

    “MD RESP-ENSURE ALL ADHERE TO P&P CFR(s): 494.150(c)(2)(i) The medical director must- (2) Ensure that- (i) All policies and procedures relative to patient admissions, patient care, infection control, and safety are adhered to by all individuals who treat patients in the facility, including attending physicians and nonphysician providers; This Standard is not met as evidenced by: 38282 Based on observation, documentation review, and staff interview, the facility failed to ensure that policies and procedures were followed for obtaining pre-treatment labs on one (1) of one (1) patient (Patient #6) observed getting pre-treatment labs. This failure has the potential to affect all patients receiving bloodwork at the facility. Cross Reference: 494.140 Personnel Qualifications. Findings are as follows: A review of the policy, titled “Drawing Blood Work Pre-Treatment from an AVI/AVG or Catheter;” dated 05/02/22 stated, in part, “All bloodwork will be obtained following the same processes to ensure consistency and accuracy of the results.” The procedure for drawing the bloodwork from a CVC [central venous catheter] was reviewed, but did not include flushing the line prior to the draw or re-instilling the blood waste. An observation was conducted on 04/08/24 starting at 12:15 p.m. of Patient #6 at Station #1. Employee #1 was accessing the venous catheter for a pre-treatment lab draw prior to the initiation of dialysis. Employee #1 sanitized their hands, donned gloves, placed a barrier under the CVC, and flushed the port with ten milliliters (10 ml) of saline. Employee #1 stated: “Oh! I need to draw labs.” Then Employee #1, without removing the gloves, left station #1 and went to the nurses station, located diagonal to station #1, and was handed a 10 cc [cubic centimeter] syringe per request. Employee #1 returned to station #1, and without removing her gloves and sanitizing her hands, pulled 10 ml of “waste” blood into the syringe. Employee #1 laid the uncapped syringe of blood on the barrier, placed the vacutainer on the port and obtained the sample for testing, and picked up the syringe of blood and reinstalled it into the catheter. Dialysis was then initiated. An interview on 04/09/24 at 9:05 a.m. with Employee #2, confirmed that policy was not followed when Employee #1 drew labs from Patient #6’s CVC. Employee #2 stated, “The procedure does not include flushing the line prior to the draw, and it should not be done, as it could affect the results. The patient labs are scheduled monthly, and the labs should have been obtained on the next visit in order to ensure a more accurate result.” Employee #2 also confirmed that there was no policy about re-instilling waste blood, and that it would place the patient at risk for infection. Employee #2 stated an adverse event report was going to be placed, and that staff required retraining.”

    Rule V0715. Standard-level.

All 2 inspections in the last three years
Inspections on record
DateVisitWhat the record says
Dec 4, 2024Standard inspectionNo deficiencies cited
Apr 10, 2024Standard inspection2 deficiencies cited

Is it certified?

  • Medicare-certified dialysis facility, certified or last recertified on Oct 12, 2016.
  • Run for profit.
  • No deficiency on record in the last three years.
  • Chain: Fresenius Medical Care.
Source:

CMS, Dialysis Facility - Listing by Facility. Released Jul 15, 2026. Updated quarterly.

CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.

Has it been penalized?

  • CMS doesn’t publish fines or other penalties for dialysis facilities.
  • None of the deficiencies cited in the last three years came from an inspection that included a complaint investigation.
Source:

CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.

What does it offer?

  • Offers in-center hemodialysis.
  • Doesn’t offer peritoneal dialysis, home hemodialysis training and a shift starting at 5 p.m. or later.
  • 13 dialysis stations.
  • CMS doesn’t publish staffing levels for dialysis facilities.
Source:

CMS, Dialysis Facility - Listing by Facility and Patient survey (ICH CAHPS) - Facility. Released Jul 15, 2026. Updated quarterly.

Who owns it?

  • Part of the Fresenius Medical Care chain, as CMS lists it.
  • CMS publishes no owners file for dialysis facilities, so no other owner is named.
Source:

CMS, Dialysis Facility - Listing by Facility. Released Jul 15, 2026. Updated quarterly.

How do patients fare?

  • CMS rates it 1 of 5 stars (Jan 1, 2021 to Dec 31, 2024).
  • Compared by CMS with what it expects for the facility’s patients: patient survival, as expected; hospital admissions, as expected; readmissions to hospital, as expected; emergency department visits, as expected; emergency department visits within 30 days of a hospital stay, as expected; bloodstream infections, as expected; patients dialysing through a fistula, as expected; patients on a kidney transplant waitlist, worse than expected.
  • CMS gives no : “Too few completed survey responses to report.”
Source:

CMS, Dialysis Facility - Listing by Facility and Patient survey (ICH CAHPS) - Facility. Released Jul 15, 2026. Updated quarterly.

Ratings and measures, as published
MeasureRating
Star ratingCMS’s star rating for dialysis facilities, 1 to 51 of 5
Patient survey ratingCMS star rating from its survey of the facility’s in-center hemodialysis patients (ICH CAHPS), 1 to 5Not rated

How does it compare nearby?

  • No other dialysis facility CMS lists is in Fayette County.
Source:

CMS, Dialysis Facility - Listing by Facility. Released Jul 15, 2026. Updated quarterly.

What the record doesn’t say

  • CMS doesn’t publish fines or other penalties for dialysis facilities, so none are shown.
  • Only complaints that led to a citation appear; complaints that didn’t aren’t published.
  • QCOR says it has no dialysis inspection reports after February 19, 2026, while it moves to a new system: a later inspection is not shown yet.
  • CMS doesn’t publish staffing levels for dialysis facilities.
  • CMS publishes no owners file for dialysis facilities: the chain it lists is the only owner named.

Sources

If you believe something here is wrong, a correction starts with the agency whose record this copies: CMS. CMS’s own record is on Care Compare. If Hearth Record copied something wrongly, it will fix it and log the correction publicly, with its date: how corrections work.

Source:

This copy of the record was made on Oct 30, 2026.

From the facility

The public record above comes first. Anything the facility adds will appear here, below it, and say who wrote it.

Replies

None. Replies aren’t open yet. When they open, the facility will be able to answer any finding for free, and the reply will show beside that finding, unedited and dated.

Paid listing

None. Paid listings aren’t open yet. When they open, anything paid for will say “Paid by the facility”, and paying will never change a finding, a rating or the order of results.

How to read a record

Four things every record does, shown on an example record made up for this guide.

An example record, made up for this guide

An example nursing home

Made up for this guide: no real place is shown

Not fully inspected in over two years (CMS flag)

11 health citations at the latest inspection cycle

The state average is 14.3.

Source:

CMS, State and US Averages and Health Deficiencies. Released Oct 28, 2026. Updated monthly.

From the homeNone yet. Replies and paid listings aren’t open, and when they open they will sit here, below the record.

1 of 4

Every fact names its source.

Who published it, when, and how often it changes sit beside each fact, with a link to the agency’s own file.

Sign in

A free account keeps your watch list, shortlists, comparisons and saved searches on every device, and can email you when something you watch changes. Browsing never needs one.