Fresenius Medical Care Greenbrier County
A dialysis facility in Lewisburg, West Virginia 24901
1255 Maplewood Ave, Lewisburg, West Virginia 24901. (304) 645-4634.
Watch and the shortlist are kept with a free account, on every device. Your watch list. CMS’s own record is on Care Compare.
The short answer
Record last released by CMS on Oct 28, 2026. We couldn’t read Centers for Medicare & Medicaid Services’ list since Nov 2, 2026: qcor.cms.gov now refuses our reader. This record is as of then.
- 1of 5 CMS’s star rating
- Not rated patient survey rating
- 2 deficiencies cited in the last three years
- 17 dialysis stations
Each figure’s source sits beside it, in its section below.
What these words mean3
- Star ratings
- CMS rates some kinds of place from 1 to 5 stars, more stars meaning better on CMS’s own measures for that kind: for a nursing home, its health inspections, staffing and quality measures. A rating is CMS’s summary of those measures; it doesn’t promise good care. Source: CMS, Care Compare and the Five-Star Quality Rating System.
- Inspection (survey)
- A visit by state inspectors, often unannounced, who check a place against the rules it must meet. For nursing homes and other places Medicare pays, CMS calls these visits surveys: a standard survey of a nursing home comes at least every 15 months, and a complaint survey whenever a complaint calls for one. Source: CMS; 42 CFR 488.308.
- Deficiency, citation, violation
- What inspectors write up when a place didn’t meet a rule: the rule, what they saw, and when. CMS calls it a deficiency; states may say citation or violation. It is the inspectors’ finding, not a court’s, and the place is usually asked for a plan to correct it. Source: CMS, statement of deficiencies (Form CMS-2567); each state’s licensing agency.
What did inspectors find?
The last inspection on record was on Dec 6, 2023: a standard inspection.
2 deficiencies cited in the last three years.
CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.
When those deficiencies happened
2 deficiencies in 1 month of the last 36. Last cited Dec 2023. Most serious: Standard-level. The last 3 years, to Oct 30, 2026.
| Jan | Feb | Mar | Apr | May | Jun | Jul | Aug | Sep | Oct | Nov | Dec | |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 2023 | Nov | Dec | ||||||||||
| 2024 | Jan | Feb | Mar | Apr | May | Jun | Jul | Aug | Sep | Oct | Nov | Dec |
| 2025 | Jan | Feb | Mar | Apr | May | Jun | Jul | Aug | Sep | Oct | Nov | Dec |
| 2026 | Jan | Feb | Mar | Apr | May | Jun | Jul | Aug | Sep | Oct |
Hover or focus a month to read it.
Hearth Record drew this from the dates and levels in the source’s own records.
Each deficiency, as cited
Rule titles as CMS’s inspectors cite them, set in sentence case.
CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.
Dec 6, 2023: standard inspection2 deficiencies
-
Ic - Sanitary Environment
The inspectors’ words, 491 words
“IC-SANITARY ENVIRONMENT CFR(s): 494.30 The dialysis facility must provide and monitor a sanitary environment to minimize the transmission of infectious agents within and between the unit and any adjacent hospital or other public areas. This Standard is not met as evidenced by: 38282 Based on observation, document review, and staff interview, it was determined Patient Care Technician (PCT) staff failed to properly sanitize their hands and change their gloves when applying a dressing to a fistula following treatment, and when changing a Central Venous Catheter (CVC) dressing prior to the initiation of treatment. This failure has the potential to adversely affect all patients. Findings include: Review of policy, titled “Personal Protective Equipment,” published 11/06/23, stated in part: “Personal protective equipment including a full-face shield or mask and protective eyewear with full side shield, fluid-resistant gowns, and gloves, must be worn to protect employees from blood or other potentially infectious materials ... (e.g. during initiation and termination of dialysis, cleaning of dialyzers, and centrifugation of blood) ... Staff must remove gloves and wash hands after: patient care, exposure to blood and body fluids, and touching any surfaces within the patient station ...” An observation was conducted on 12/04/23 at 3:32 p.m. of PCT #1 dressing a fistula at the end of treatment at station #8. The patient had been disconnected from the machine, and a pressure dressing had been applied. The patient was wearing a face mask, and had donned a glove and was holding pressure to the site. PCT #1 removed their gloves, sanitized their hands, and donned gloves. PCT #1 proceeded to program the computer, gather and discard the tubing, and collect patient belongings and hang them on the back of the wheelchair. PCT #1 then checked the fistula site, added tape, and held pressure for a few seconds without changing their gloves. Several times during the procedure, PCT #1’s face mask was noted to be improperly worn below the nose, prompting readjustment without washing hands or replacing gloves. An observation was conducted on 12/05/23 at 10:30 a.m. of PCT #2 changing the dressing on a CVC prior to the initiation of treatment at station #7. PCT #2 was observed removing and discarding the old dressing and a bandaid on the right chest next to the dressing, cleaning the CVC exit area with antiseptic and allowing it to dry, then applying a new dressing, all while donning the same gloves. Following the procedure, hands were sanitized and gloves were changed. The patient wore a mask throughout the procedure. An interview conducted on 12/05/23 at 12:50 p.m. with a Registered Nurse (RN) confirmed that PCT #1 and PCT #2 had not followed established protocols, and that the improper use of personal protective equipment (PPE) increases the chance of infection. The RN stated, “Whenever I see the staff performing improper procedures or the misuse of PPE, I address it immediately with that staff. We also hold annual training sessions for all staff.””
-
Ic - Wear Gowns, Shields/Masks; Staff Not Eat/Drink In Tx Area
The inspectors’ words, 741 words
“IC-GOWNS, SHIELDS/MASKS-NO STAFF EAT/DRINK CFR(s): 494.30(a)(1)(i) Staff members should wear gowns, face shields, eye wear, or masks to protect themselves and prevent soiling of clothing when performing procedures during which spurting or spattering of blood might occur (e.g., during initiation and termination of dialysis, cleaning of dialyzers, and centrifugation of blood). Staff members should not eat, drink, or smoke in the dialysis treatment area or in the laboratory. This Standard is not met as evidenced by: 38282 Based on observation, document review, and staff interview, it was determined Patient Care Technician (PCT) staff failed to wear proper personal protective equipment (PPE) when applying a dressing to a fistula following treatment, changing a Central Venous Catheter (CVC) dressing prior to the initiation of treatment, and cleaning and preparing a station between patients. This failure has the potential to adversely affect all patients. Findings include: Review of policy, titled “Personal Protective Equipment,” published 11/06/23, stated in part: “Personal protective equipment including a full-face shield or mask and protective eyewear with full side shield, fluid-resistant gowns, and gloves, must be worn to protect employees from blood or other potentially infectious materials ... (e.g. during initiation and termination of dialysis, cleaning of dialyzers, and centrifugation of blood) ... Staff must remove gloves and wash hands after: patient care, exposure to blood and body fluids, and touching any surfaces within the patient station ...” Review of policy, titled “Exposure Task List,” revised 10/10/08, delineates the PPE equipment required during various procedures, and states in part: “Gowns, face shields, and face masks are to be worn, and hand hygiene and gloves are to be changed: After each patient contact care activity when touching any part of the dialysis machine or equipment at the dialysis station, ... Change catheter dressing, ... and stripping machine after patient treatment ... Footnotes: When face shield is used a mask is also required to prevent airborne contamination of catheter exit site from breath escaping under the edge of the face shield patient must also wear a mask.” An observation was conducted on 12/04/23 at 3:32 p.m. of PCT #1 dressing a fistula at the end of treatment at station #8. The patient had been disconnected from the machine, and a pressure dressing had been applied. The patient was wearing a mask and had donned a glove, and was holding pressure to the site. PCT #1 removed their gloves, sanitized their hands, and donned gloves. PCT #1 then proceeded to program the computer, gather and discard the tubing, and collect patient belongings. PCT #1 then checked the fistula site, added tape, and held pressure for a few seconds without changing their gloves. Several times during the procedure, PCT #1’s face mask was noted to be improperly worn below the nose, prompting readjustment without washing hands or replacing gloves. An observation was conducted on 10/05/23 at 10:30 a.m. of PCT #2 changing the dressing on a CVC prior to the initiation of treatment at station #7. The patient was wearing a mask. PCT #2 was observed removing and discarding the old dressing, cleaning the CVC exit area with antiseptic and allowing it to dry, then applying a new dressing, all while donning the same gloves. Following the procedure, hands were sanitized and gloves were changed. An observation was conducted on 12/05/23 at 10:50 a.m. of PCT #1 cleaning and preparing station #3 between patients. PCT #1 wore the face shield improperly on the top of the head, and the face mask was noted to be improperly worn below the nose, prompting readjustment throughout the procedure. An interview conducted on 12/05/23 at 12:50 p.m. with a Registered Nurse (RN) confirmed that PCT #1 and PCT #2 had not followed established protocols, and that the improper use of PPE increases the chance of infection. The RN stated, “Whenever I see the staff performing improper procedures or the misuse of PPE, I address it immediately with that staff. We also hold annual training sessions for all staff.” Regarding not wearing the proper PPE to clean the machine, the RN confirmed that the staff “was not wearing the PPE properly and they needed to because of the risk of bleach splash back.” An interview was conducted on 12/06/23 at 10:30 a.m. with the Clinical Manager (CM) regarding the use of PPE. The CM concurred that wearing a face shield on the top of the head and a mask under the nose was not the proper use of PPE.”
The one inspection in the last three years
| Date | Visit | What the record says |
|---|---|---|
| Dec 6, 2023 | Standard inspection | 2 deficiencies cited |
Is it certified?
- Medicare-certified dialysis facility, certified or last recertified on Nov 18, 2009.
- Run for profit.
- No For hospices, home health agencies, hospitals and dialysis facilities, CMS writes deficiencies at two levels. Standard is the usual one; condition-level is the more serious, when a problem is serious enough that the provider doesn’t meet a whole condition of taking part in Medicare. Source: CMS, State Operations Manual. deficiency on record in the last three years.
- Chain: Fresenius Medical Care.
CMS, Dialysis Facility - Listing by Facility. Released Jul 15, 2026. Updated quarterly.
CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.
Has it been penalized?
- CMS doesn’t publish fines or other penalties for dialysis facilities.
- None of the deficiencies cited in the last three years came from an inspection that included a complaint investigation.
CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.
What does it offer?
- Offers in-center hemodialysis, peritoneal dialysis and home hemodialysis training.
- Doesn’t offer a shift starting at 5 p.m. or later.
- 17 dialysis stations.
- CMS doesn’t publish staffing levels for dialysis facilities.
CMS, Dialysis Facility - Listing by Facility and Patient survey (ICH CAHPS) - Facility. Released Jul 15, 2026. Updated quarterly.
Who owns it?
- Part of the Fresenius Medical Care chain, as CMS lists it.
- CMS publishes no owners file for dialysis facilities, so no other owner is named.
CMS, Dialysis Facility - Listing by Facility. Released Jul 15, 2026. Updated quarterly.
How do patients fare?
- CMS rates it 1 of 5 stars (Jan 1, 2021 to Dec 31, 2024).
- Compared by CMS with what it expects for the facility’s patients: patient survival, as expected; hospital admissions, as expected; readmissions to hospital, as expected; blood transfusions, as expected; emergency department visits, as expected; emergency department visits within 30 days of a hospital stay, as expected; bloodstream infections, better than expected; patients dialysing through a fistula, as expected; patients put on a kidney transplant waitlist in their first year of dialysis, as expected; patients on a kidney transplant waitlist, as expected.
- CMS gives no CMS rates some kinds of place from 1 to 5 stars, more stars meaning better on CMS’s own measures for that kind: for a nursing home, its health inspections, staffing and quality measures. A rating is CMS’s summary of those measures; it doesn’t promise good care. Source: CMS, Care Compare and the Five-Star Quality Rating System.: “Too few completed survey responses to report.”
CMS, Dialysis Facility - Listing by Facility and Patient survey (ICH CAHPS) - Facility. Released Jul 15, 2026. Updated quarterly.
| Measure | Rating |
|---|---|
| Star ratingCMS’s star rating for dialysis facilities, 1 to 5 | 1 of 5 |
| Patient survey ratingCMS star rating from its survey of the facility’s in-center hemodialysis patients (ICH CAHPS), 1 to 5 | Not rated |
How does it compare nearby?
- No other dialysis facility CMS lists is in Greenbrier County.
CMS, Dialysis Facility - Listing by Facility. Released Jul 15, 2026. Updated quarterly.
What the record doesn’t say
- CMS doesn’t publish fines or other penalties for dialysis facilities, so none are shown.
- Only complaints that led to a citation appear; complaints that didn’t aren’t published.
- QCOR says it has no dialysis inspection reports after February 19, 2026, while it moves to a new system: a later inspection is not shown yet.
- CMS doesn’t publish staffing levels for dialysis facilities.
- CMS publishes no owners file for dialysis facilities: the chain it lists is the only owner named.
Sources
-
Centers for Medicare & Medicaid Services, Dialysis Facility - Listing by Facility (23ew-n7w9).
Released Jul 15, 2026 and checked Oct 30, 2026. Updated quarterly. Public domain (U.S. Government work).
-
Centers for Medicare & Medicaid Services, Patient survey (ICH CAHPS) - Facility (59mq-zhts).
Released Jul 15, 2026 and checked Oct 30, 2026. Updated quarterly. Public domain (U.S. Government work).
-
Centers for Medicare & Medicaid Services, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies (ESRD_2567s_2018_to_2026YTD.xlsx).
Released Oct 28, 2026 and checked Oct 30, 2026. Updated monthly. Public domain (U.S. Government work).
If you believe something here is wrong, a correction starts with the agency whose record this copies: CMS. CMS’s own record is on Care Compare. If Hearth Record copied something wrongly, it will fix it and log the correction publicly, with its date: how corrections work.
This copy of the record was made on Oct 30, 2026.
From the facility
The public record above comes first. Anything the facility adds will appear here, below it, and say who wrote it.
Replies
None. Replies aren’t open yet. When they open, the facility will be able to answer any finding for free, and the reply will show beside that finding, unedited and dated.
Paid listing
None. Paid listings aren’t open yet. When they open, anything paid for will say “Paid by the facility”, and paying will never change a finding, a rating or the order of results.