The short answer

Record last released by CMS on Oct 28, 2026.

The last 24 months 7 deficiencies in 1 month of the last 36. Last cited Aug 2025. Most serious: Standard-level. Every month

Each figure’s source sits beside it, in its section below.

What these words mean3
Star ratings
CMS rates some kinds of place from 1 to 5 stars, more stars meaning better on CMS’s own measures for that kind: for a nursing home, its health inspections, staffing and quality measures. A rating is CMS’s summary of those measures; it doesn’t promise good care. Source: CMS, Care Compare and the Five-Star Quality Rating System.
Inspection (survey)
A visit by state inspectors, often unannounced, who check a place against the rules it must meet. For nursing homes and other places Medicare pays, CMS calls these visits surveys: a standard survey of a nursing home comes at least every 15 months, and a complaint survey whenever a complaint calls for one. Source: CMS; 42 CFR 488.308.
Deficiency, citation, violation
What inspectors write up when a place didn’t meet a rule: the rule, what they saw, and when. CMS calls it a deficiency; states may say citation or violation. It is the inspectors’ finding, not a court’s, and the place is usually asked for a plan to correct it. Source: CMS, statement of deficiencies (Form CMS-2567); each state’s licensing agency.

What did inspectors find?

The last inspection on record was on Aug 27, 2025: a standard inspection.

7 deficiencies cited in the last three years.

Source:

CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.

When those deficiencies happened

7 deficiencies in 1 month of the last 36. Last cited Aug 2025. Most serious: Standard-level. The last 3 years, to Oct 30, 2026.

7 deficiencies by month over the last 3 years. Each cell is one month.
JanFebMarAprMayJunJulAugSepOctNovDec
2023 NovDec
2024 JanFebMarAprMayJunJulAugSepOctNovDec
2025 JanFebMarAprMayJunJulAugSepOctNovDec
2026 JanFebMarAprMayJunJulAugSepOct

Hover or focus a month to read it.

No visit on record Visited, nothing cited A stronger orange is more serious, on its source’s own levels, read onto four bands: from the least serious it publishes to the most
Source:

Hearth Record drew this from the dates and levels in the source’s own records.

Each deficiency, as cited

Rule titles as CMS’s inspectors cite them, set in sentence case.

Source:

CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.

Aug 27, 2025: standard inspection7 deficiencies
  • Ic - Wear Gloves/Hand Hygiene

    The inspectors’ words, 189 words

    “IC-WEAR GLOVES/HAND HYGIENE CFR(s): 494.30(a)(1) Wear disposable gloves when caring for the patient or touching the patient’s equipment at the dialysis station. Staff must remove gloves and wash hands between each patient or station. This Standard is not met as evidenced by: 47413 Based on record review, observation and interview, the facility staff failed to wear gloves when touching the dialysis machine for 3 of 13 patients (Patients #10, 11, 12) in a total of 16 observations of patient care. Findings Include: A review of the facility’s policy titled, “Dialysis Unit Infection Specific Precautions” last reviewed 03/15/2024 revealed, “... Gloves are required whenever caring for patients or touching patients’ equipment...” During an observation on 08/26/2025 at 9:16 AM, Hemodialysis Technician F touched Patient #12’s dialysis machine without gloves. During an observation on 08/26/2025 at 10:13 AM, Registered Nurse B touched Patient #10’s dialysis machine without gloves. During an observation on 08/26/2025 at 10:40 AM, Registered Nurse C touched Patient #11’s dialysis machine without gloves. During an interview on 08/27/2025 at 11:21 AM, Dialysis Director A stated the policy is that staff need to wear gloves when touching the machine.”

    Rule V0113. Standard-level.

  • Ic - Clean, Disinfect Surfaces & Equipment/Written Protocols

    The inspectors’ words, 211 words

    “IC-DISINFECT SURFACES/EQUIP/WRITTEN PROTOCOL CFR(s): 494.30(a)(4)(ii) [The facility must demonstrate that it follows standard infection control precautions by implementing- (4) And maintaining procedures, in accordance with applicable State and local laws and accepted public health procedures, for the-] (ii) Cleaning and disinfection of contaminated surfaces, medical devices, and equipment. This Standard is not met as evidenced by: 29963 47413 Based on record review, observation and interview, the facility staff failed to complete disinfection of all equipment in the dialysis station for 2 of 2 dialysis stations (Stations #9, 17) observed being cleaned in a total of 16 observations of patient care. Findings Include: A review of the facility’s policy titled, “Cleaning and Disinfection Procedures for the Dialysis Machines and Equipment” last reviewed 02/05/2024 revealed, “... Disinfect machine... Disinfect chair/bed, TV, blood pressure cuff...” During an observation on 08/26/2025 at 9:40 AM, Patient Care Technician H was observed cleaning Station #9 and did not wipe down the hooks on the IV pole or the TV. During an observation on 08/26/2025 at 9:45 AM, Hemodialysis Technician D was observed cleaning Station #17 and did not wipe down the hooks on the IV pole. During an interview on 08/27/2025 at 11:20 AM, Dialysis Director A stated that the entire machine and surfaces should be disinfected.”

    Rule V0122. Standard-level.

  • Ic - Staff Education Re Catheters/Catheter Care

    The inspectors’ words, 278 words

    “IC-STAFF EDUCATION-CATHETERS/CATHETER CARE CFR(s): 494.30(a)(2) Recommendations for Placement of Intravascular Catheters in Adults and Children I. Health care worker education and training A. Educate health-care workers regarding the ... appropriate infection control measures to prevent intravascular catheter-related infections. B. Assess knowledge of and adherence to guidelines periodically for all persons who manage intravascular catheters. II. Surveillance A. Monitor the catheter sites visually of individual patients. If patients have tenderness at the insertion site, fever without obvious source, or other manifestations suggesting local or BSI [blood stream infection], the dressing should be removed to allow thorough examination of the site. Central Venous Catheters, Including PICCs, Hemodialysis, and Pulmonary Artery Catheters in Adult and Pediatric Patients. VI. Catheter and catheter-site care B. Antibiotic lock solutions: Do not routinely use antibiotic lock solutions to prevent CRBSI [catheter related blood stream infections]. This Standard is not met as evidenced by: 47413 Based on record review, observation and interview, facility staff failed to wear a mask during discontinuation of dialysis with a central venous catheter in 1 of 2 patients (Patient #11) in a total sample of 2 observations of care of patients with a CVC. Findings Include: A review of the facility’s policy titled, “Central Venous Access Device (CVAD), Chronic Hemodialysis Access” last reviewed 08/21/2025 revealed, “... Termination of Hemodialysis Treatment... Apply mask to patient and associates...” During an observation on 08/26/2025 at 10:40 AM Registered Nurse C was observed discontinuing dialysis on Patient #11 who had a CVC. Registered Nurse C was not wearing a mask. On 08/27/2025 at 11:13 AM, the observation findings were discussed with Dialysis Director A who stated that masks need to be worn with CVC care.”

    Rule V0147. Standard-level.

  • Pe - Equipment Maintenance - Manufacturer’S Dfu

    The inspectors’ words, 178 words

    “PE-EQUIPMENT MAINTENANCE-MANUFACTURER’S DFU CFR(s): 494.60(b) The dialysis facility must implement and maintain a program to ensure that all equipment (including emergency equipment, dialysis machines and equipment, and the water treatment system) are maintained and operated in accordance with the manufacturer’s recommendations. This Standard is not met as evidenced by: 29963 Based on observation and interview, staff failed to maintain a sanitary environment free from potential infection risk in 5 of 19 dialysis treatment stations (#7, 17, 1, 18, and the isolation room) in a total of 19 stations observed. Findings Include: Observation on 08/27/2024 at 4:27 PM revealed the following findings: Dialysis chair at station #7 and #17 had tears in the vinyl material exposing a porous surface making it difficult to disinfect. The walls at station #1, station #18, and the isolation room had scuffs in the drywall exposing a porous surface making it difficult to disinfect. During an interview on 08/27/2024 at 4:30 PM, Regulatory Specialist R stated the walls get bumped with equipment. Regulatory Specialist R stated it does make those areas hard to clean.”

    Rule V0403. Standard-level.

  • Patient Assessment - Interdisciplinary Team Mbrs/Resp.

    The inspectors’ words, 418 words

    “PA-IDT MEMBERS/RESPONSIBILITIES CFR(s): 494.80 The facility’s interdisciplinary team consists of, at a minimum, the patient or the patient’s designee (if the patient chooses), a registered nurse, a physician treating the patient for ESRD, a social worker, and a dietitian. The interdisciplinary team is responsible for providing each patient with an individualized and comprehensive assessment of his or her needs. The comprehensive assessment must be used to develop the patient’s treatment plan and expectations for care. This Standard is not met as evidenced by: 29963 Based on record review and interview the staff failed to ensure all members of the interdisciplinary team complete a comprehensive assessment of the patients’ needs prior to the care plan meeting in 2 of 7 patient records reviewed (Patient #1, 5) in a total sample of 7 medical records reviewed. Findings Include: A review of policy titled, “Assessment and Care Planning of the Dialysis Patient” dated 05/05/2021 revealed, “Patients new to dialysis will have comprehensive assessments by the interdisciplinary team (IDT) along with the development of an individualized care plan. This requirement applies to all new dialysis patients, without regard to the modality of treatment. Patients returning to dialysis from a failed transplant or changing modalities are also considered new patients. 1) A comprehensive initial patient assessment will be completed within the first 30 days of first 13 treatments. 2) Comprehensive re-assessment will be done within 90 days of the completion of the initial assessment ...” A review of Patient #5’s medical record revealed Patient #5 returned to in-center hemodialysis on 05/27/2025 after developing an infection during peritoneal dialysis. A comprehensive initial patient assessment was completed on 06/10/2025. The comprehensive re-assessment dated 08/18/2025 was not completed by the nurse. A review of the comprehensive re-assessment revealed, “Care team members have met as a team to review the assessment and create/update the plans of care- dated 08/25/2025. A review of Patient #1’s medical record revealed Patient #1 starting in-center hemodialysis on 07/11/2025. A comprehensive initial patient assessment was dated 08/13/2025 the assessment was not completed by the nurse, physician, or the social worker. A review of the comprehensive interdisciplinary initial assessment revealed, “Patient is Unstable”. During an interview on 08/27/2025 at 8:30 AM, the medical record review findings were discussed with and confirmed by Lead Registered Nurse M who stated the comprehensive interdisciplinary assessment were not completed. During an interview on 08/27/2025 at 8:40 AM, Dialysis Director A stated it is the responsibility of the primary nurse and the social worker to complete the assessment.”

    Rule V0501. Standard-level.

  • Appropriateness Of Dialysis Rx

    The inspectors’ words, 529 words

    “PA-APPROPRIATENESS OF DIALYSIS RX CFR(s): 494.80(a)(2) The patient’s comprehensive assessment must include, but is not limited to, the following: (2) Evaluation of the appropriateness of the dialysis prescription, This Standard is not met as evidenced by: 29963 47413 Based on record review and interview, the facility staff failed to ensure the administration of the pre-treatment Heparin bolus was at least 3 to 5 minutes prior to the initiation of dialysis, per facility policy, in 3 of 4 in-center hemodialysis patients (Patients #1, 3, 4) with current active orders for Heparin boluses and failed to ensure the prescribed dose of Heparin was given to 1 of 4 in-center hemodialysis patients (Patients #1) with Heparin infusion orders in a total universe of 7 medical records reviewed. Findings Include: A review of facility policy titled, “Initiation and Termination of Hemodialysis” last reviewed 04/08/2025 revealed, “... 12) Administer prescribed heparin bolus and wait 3-5 minutes prior to starting dialysis... 18) Set heparin pump to prescribed rate... “ Example of Heparin Bolus Not Administered Per Policy: A review of Patient #1’s current in-center hemodialysis order revealed an order for 500 units of Heparin bolus. A review of treatment sheet dated 08/23/2025 revealed Patient #1’s dialysis was started at 11:32 AM. “Medications Administered” revealed the Heparin bolus was documented as given at 11:30 AM, 2 minutes before the initiation of dialysis. A review of Patient #3’s current in-center hemodialysis orders revealed an order for 2000 units of Heparin bolus. A review of treatment sheet dated 08/16/2025 revealed Patient #3’s dialysis was started at 6:49 AM. “Medications Administered” revealed the Heparin bolus was documented as given at 6:49 AM, the same time as initiation of dialysis. A review of Patient #4’s current in-center hemodialysis orders revealed an order for 2000 units of Heparin bolus. A review of treatment sheet dated 08/13/2025 revealed Patient #4’s dialysis was started at 10:42 AM. “Medications Administered” revealed the Heparin bolus was documented as given at 10:42 AM, the same time as initiation of dialysis. During an interview on 08/27/2025 at 8:30 AM, the medical record review findings were discussed with Dialysis Director A who stated, “The Heparin bolus should be given 3-5 minutes prior.” Example of Heparin Infusion Not Administered as Ordered: A review of Patient #1’s current in-center hemodialysis orders revealed an order for Heparin infusion of 500 units per hour for 210 minutes (3 hours and 30 minutes). The total infusion dosage ordered was 1.75 units. The treatment sheet dated 08/12/2025 revealed Patient #1’s treatment ran for 214 minutes (3 hours and 34 minutes). In the “Heparin” column on the Intradialytics flow sheet, 0.9 units of Heparin infusion was documented as administered, .85 units less than ordered. The treatment sheet dated 08/23/2025 revealed Patient #1’s treatment ran for 209 minutes (3 hours and 33 minutes). In the “Heparin” column on the Intradialytics flow sheet, 1.2 units of Heparin infusion was documented as administered, .55 units less than ordered. During an interview on 08/27/2025 at 9:11 AM, the medical record review findings were discussed with and confirmed by Lead Registered Nurse M who stated it looks like the pump was not set correctly, more heparin should have been given.”

    Rule V0503. Standard-level.

  • Measure, Analyze And Track Quality Indicators

    The inspectors’ words, 264 words

    “QAPI-MEASURE/ANALYZE/TRACK QUAL INDICATORS CFR(s): 494.110(a)(2) The dialysis facility must measure, analyze, and track quality indicators or other aspects of performance that the facility adopts or develops that reflect processes of care and facility operations. These performance components must influence or relate to the desired outcomes or be the outcomes themselves. This Standard is not met as evidenced by: 29963 Based on record review and interview, the facility staff failed to ensure data is being collected, analyzed, and trended to identify potential problems with blood pressure monitoring for 2 of 2 dialysis programs (In-center and Home Dialysis) in the monthly quality meetings for a total of 2 dialysis services offered at this dialysis facility. Findings include: A review of the facility’s policy titled, “Quality Assessment and Performance Improvement,” effective date, 02/09/2024 revealed, “3) The Renal Service Team will provide oversight to the continuous monitoring, analyzing, and performance improvement of clinical and other processes that improve and identify outcomes... 5) The dialysis facility will monitor its performance; take actions that result in performance improvements, and track performance to ensure that improvements are sustained over time. b) Data is reviewed by the Medical Director.” A review of the facility’s Quality Assessment and Performance Improvement Program with Dialysis Director A, including data from May 2025 through July 2025 revealed the In-Center and Home Dialysis quality program dashboard does not include documentation related to data for blood pressure management for In-center or home dialysis patients. During an interview on 08/26/2024 at 3:25 PM, Dialysis Director A stated, the facility’s quality program does not have data regarding blood pressure management.”

    Rule V0628. Standard-level.

The one inspection in the last three years
Inspections on record
DateVisitWhat the record says
Aug 27, 2025Standard inspection7 deficiencies cited

Is it certified?

  • Medicare-certified dialysis facility, certified or last recertified on May 19, 1993.
  • Run as a non-profit.
  • No deficiency on record in the last three years.
Source:

CMS, Dialysis Facility - Listing by Facility. Released Jul 15, 2026. Updated quarterly.

CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.

Has it been penalized?

  • CMS doesn’t publish fines or other penalties for dialysis facilities.
  • None of the deficiencies cited in the last three years came from an inspection that included a complaint investigation.
Source:

CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.

What does it offer?

  • Offers in-center hemodialysis, peritoneal dialysis and home hemodialysis training.
  • Doesn’t offer a shift starting at 5 p.m. or later.
  • 19 dialysis stations.
  • CMS doesn’t publish staffing levels for dialysis facilities.
Source:

CMS, Dialysis Facility - Listing by Facility and Patient survey (ICH CAHPS) - Facility. Released Jul 15, 2026. Updated quarterly.

Who owns it?

  • CMS lists it as independent, not owned or managed by a chain.
  • CMS publishes no owners file for dialysis facilities, so no other owner is named.
Source:

CMS, Dialysis Facility - Listing by Facility. Released Jul 15, 2026. Updated quarterly.

How do patients fare?

  • CMS rates it 4 of 5 stars (Jan 1, 2021 to Dec 31, 2024).
  • Compared by CMS with what it expects for the facility’s patients: patient survival, as expected; hospital admissions, better than expected; readmissions to hospital, as expected; blood transfusions, as expected; emergency department visits, as expected; emergency department visits within 30 days of a hospital stay, as expected; bloodstream infections, as expected; patients dialysing through a fistula, as expected; patients put on a kidney transplant waitlist in their first year of dialysis, as expected; patients on a kidney transplant waitlist, as expected.
  • CMS gives no : “Too few completed survey responses to report.”
Source:

CMS, Dialysis Facility - Listing by Facility and Patient survey (ICH CAHPS) - Facility. Released Jul 15, 2026. Updated quarterly.

Ratings and measures, as published
MeasureRating
Star ratingCMS’s star rating for dialysis facilities, 1 to 54 of 5
Patient survey ratingCMS star rating from its survey of the facility’s in-center hemodialysis patients (ICH CAHPS), 1 to 5Not rated

How does it compare nearby?

  • Of the 3 dialysis facilities CMS lists in Fond Du Lac County, 3 have a star rating from CMS: 1 rated 4 of 5, 1 rated 3 of 5, 1 rated 2 of 5.
  • CMS rates this one 4 of 5.
Source:

CMS, Dialysis Facility - Listing by Facility. Released Jul 15, 2026. Updated quarterly.

2 compared
PlaceStar rating
Davita Fond Du Lac Dialysis2
Fmc - Ripon South3

What the record doesn’t say

  • CMS doesn’t publish fines or other penalties for dialysis facilities, so none are shown.
  • Only complaints that led to a citation appear; complaints that didn’t aren’t published.
  • QCOR says it has no dialysis inspection reports after February 19, 2026, while it moves to a new system: a later inspection is not shown yet.
  • CMS doesn’t publish staffing levels for dialysis facilities.
  • CMS publishes no owners file for dialysis facilities: the chain it lists is the only owner named.

Sources

If you believe something here is wrong, a correction starts with the agency whose record this copies: CMS. CMS’s own record is on Care Compare. If Hearth Record copied something wrongly, it will fix it and log the correction publicly, with its date: how corrections work.

Source:

This copy of the record was made on Oct 30, 2026.

From the facility

The public record above comes first. Anything the facility adds will appear here, below it, and say who wrote it.

Replies

None. Replies aren’t open yet. When they open, the facility will be able to answer any finding for free, and the reply will show beside that finding, unedited and dated.

Paid listing

None. Paid listings aren’t open yet. When they open, anything paid for will say “Paid by the facility”, and paying will never change a finding, a rating or the order of results.

How to read a record

Four things every record does, shown on an example record made up for this guide.

An example record, made up for this guide

An example nursing home

Made up for this guide: no real place is shown

Not fully inspected in over two years (CMS flag)

11 health citations at the latest inspection cycle

The state average is 14.3.

Source:

CMS, State and US Averages and Health Deficiencies. Released Oct 28, 2026. Updated monthly.

From the homeNone yet. Replies and paid listings aren’t open, and when they open they will sit here, below the record.

1 of 4

Every fact names its source.

Who published it, when, and how often it changes sit beside each fact, with a link to the agency’s own file.

Sign in

A free account keeps your watch list, shortlists, comparisons and saved searches on every device, and can email you when something you watch changes. Browsing never needs one.