Fmc Omak Dialysis Center

A dialysis facility in Omak, Washington 98841

800 Jasmine St. Suite 1, Omak, Washington 98841. (509) 826-8680.

CMS’s own record, on Care Compare

Watch and the shortlist are kept with a free account, on every device. Your watch list. CMS’s own record is on Care Compare.

The short answer

Record last released by CMS on Oct 28, 2026. We couldn’t read Centers for Medicare & Medicaid Services’ list since Nov 2, 2026: qcor.cms.gov now refuses our reader. This record is as of then.

The last 24 months 6 deficiencies in 1 month of the last 36. Last cited Jan 2025. Most serious: Standard-level. Every month

Each figure’s source sits beside it, in its section below.

What these words mean3
Star ratings
CMS rates some kinds of place from 1 to 5 stars, more stars meaning better on CMS’s own measures for that kind: for a nursing home, its health inspections, staffing and quality measures. A rating is CMS’s summary of those measures; it doesn’t promise good care. Source: CMS, Care Compare and the Five-Star Quality Rating System.
Inspection (survey)
A visit by state inspectors, often unannounced, who check a place against the rules it must meet. For nursing homes and other places Medicare pays, CMS calls these visits surveys: a standard survey of a nursing home comes at least every 15 months, and a complaint survey whenever a complaint calls for one. Source: CMS; 42 CFR 488.308.
Deficiency, citation, violation
What inspectors write up when a place didn’t meet a rule: the rule, what they saw, and when. CMS calls it a deficiency; states may say citation or violation. It is the inspectors’ finding, not a court’s, and the place is usually asked for a plan to correct it. Source: CMS, statement of deficiencies (Form CMS-2567); each state’s licensing agency.

What did inspectors find?

The last inspection on record was on Jan 8, 2025: a standard inspection.

6 deficiencies cited in the last three years.

Source:

CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.

When those deficiencies happened

6 deficiencies in 1 month of the last 36. Last cited Jan 2025. Most serious: Standard-level. The last 3 years, to Oct 30, 2026.

6 deficiencies by month over the last 3 years. Each cell is one month.
JanFebMarAprMayJunJulAugSepOctNovDec
2023 NovDec
2024 JanFebMarAprMayJunJulAugSepOctNovDec
2025 JanFebMarAprMayJunJulAugSepOctNovDec
2026 JanFebMarAprMayJunJulAugSepOct

Hover or focus a month to read it.

No visit on record Visited, nothing cited A stronger orange is more serious, on its source’s own levels, read onto four bands: from the least serious it publishes to the most
Source:

Hearth Record drew this from the dates and levels in the source’s own records.

Each deficiency, as cited

Rule titles as CMS’s inspectors cite them, set in sentence case.

Source:

CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.

Jan 8, 2025: standard inspection6 deficiencies
  • Ic - Items Taken To Station Disposed/Dedicated Or Disinfected

    The inspectors’ words, 582 words

    “IC-IF TO STATION=DISP/DEDICATE OR DISINFECT CFR(s): 494.30(a)(1)(i) Items taken into the dialysis station should either be disposed of, dedicated for use only on a single patient, or cleaned and disinfected before being taken to a common clean area or used on another patient. -- Nondisposable items that cannot be cleaned and disinfected (e.g., adhesive tape, cloth covered blood pressure cuffs) should be dedicated for use only on a single patient. -- Unused medications (including multiple dose vials containing diluents) or supplies (syringes, alcohol swabs, etc.) taken to the patient’s station should be used only for that patient and should not be returned to a common clean area or used on other patients. This Standard is not met as evidenced by: 22198 Based on observation, interview, and policy review, the facility failed to ensure that for one of two observation days on blood pressure (BP) cuffs dedicated to a dialysis station were clean or disinfected prior to taking them out of one station and into another dialysis station. This has the potential for cross contamination and could affect all 55 in-center dialysis patients. Findings include: During an observation on 01/06/25 at 11:53 AM Patient Care Technician (PCT) 1 was observed initiating dialysis at dialysis Station #17, while taking patient (P) 2’s BP, PCT1 realized it was the wrong size causing an incorrect reading. Wearing the same gloves, PCT1 left dialysis Station #17 walked over to dialysis Station #16 that was empty, picked up the BP cuff and realized it was not the correct size and placed it back into the basket on the side of dialysis Station #16. Continuing looking for a BP cuff for P2 wearing the same gloves PCT1 walked in dialysis Station #12 that was evidently not cleaned (empty supply wraps and BP cuff attached to the dialysis machine were laying on the chair) picked up the BP cuff that was in the dialysis machine basket and took it into Station #17 and used it on P2 without cleaning the BP cuff. During an interview on 01/07/25 10:40 AM, PCT1 was asked about cleaning BP cuffs in the dialysis machine basket, and PCT1 stated, he/she thought the extra BP cuff stored on the dialysis machines only needed to be cleaned if they were used. Review of the facility’s policy titled, “Cleaning and Disinfecting the Dialysis Station,” dated 09/05/23, revealed, “The Centers for Medicare and Medicaid Services (CMS) has regulations that in order to prevent cross contamination, a dialysis station must be cleaned and disinfected between dialysis patients. The chair and dialysis equipment are used by multiple patients during a treatment day, and it is critical that these items be thoroughly cleaned and disinfected between uses. Also, the nature of dialysis treatments with frequent exposure to blood and body fluids, close proximity of patients and staff, and the immunocompromised status of dialysis patients make dialysis a high-risk area for spreading infectious disease. ... Definition Dialysis Station: Area including the dialysis machine, chair/bed and other reusable equipment or supplies utilized during dialysis treatment, patient training, and/or patient clinic visits. Equipment in the dialysis station may include (but is not limited to) the following: o Dialysis machine cycler and attachments such as IV [intravenous] pole, BP cuff and ...The dialysis station could become contaminated with blood and other body fluids during treatment. After use, any non-disposable equipment and supplies brought into the dialysis station (ex. Stethoscope) must be disinfected with 1:100 bleach or EPA registered disinfectant before being removed from the dialysis station.””

    Rule V0116. Standard-level.

  • Ic - Clean/Dirty Areas, Med Prep Area, No Common Med Carts

    The inspectors’ words, 509 words

    “IC-CLEAN/DIRTY;MED PREP AREA;NO COMMON CARTS CFR(s): 494.30(a)(1)(i) Clean areas should be clearly designated for the preparation, handling and storage of medications and unused supplies and equipment. Clean areas should be clearly separated from contaminated areas where used supplies and equipment are handled. Do not handle and store medications or clean supplies in the same or an adjacent area to that where used equipment or blood samples are handled. When multiple dose medication vials are used (including vials containing diluents), prepare individual patient doses in a clean (centralized) area away from dialysis stations and deliver separately to each patient. Do not carry multiple dose medication vials from station to station. Do not use common medication carts to deliver medications to patients. If trays are used to deliver medications to individual patients, they must be cleaned between patients. This Standard is not met as evidenced by: 22198 Based on observation, interviews and policy review, the facility failed to ensure staff maintained a separation between clean and dirty area/supplies for one of two dialysis treatment area observation days. This failure had the potential for contaminating clean patient supplies and could affect all 55 in-center dialysis patients. Findings include: During an observation on 01/07/25 at 11:15 AM Patient Care Technician (PCT) 1 and PCT3 were using a Hoyer lift to get patient (P) 9 from a wheelchair into the dialysis chair at dialysis Station #9, PCT1 removed the blanket and pillow from P9’s lap and set it on the clean supply counter that contained the prepared clean and sterile dialysis supplies for the day (dialyzers, needles, 2x2 gauze pads, etc. ...) At 11:40 AM, after dialysis treatment was started for P9, PCT1 turned around and removed P9’s pillow and blanket from the clean supply counter and gave it to P9. During an interview on 01/07/25 at 11:40 AM, PCT1 was asked if the countertop was a clean or dirty space. PCT1 confirmed the countertop was a clean space. PCT1 was asked in patient’s personal belonging were clean or dirty, PCT1 replied “dirty” PCT1 was asked if the patient’s personal belongings should be placed on a clean countertop, PCT1 stated “probably not”. Review of the facility’s policy titled, “General Cleanliness and Infection Control Guidelines,” dated 11/04/24, revealed, “The purpose of this policy is to provide guidance for FKC [Fresenius Kidney Care] staff on preventing the spread of infectious disease and maintaining a clean, safe, and aesthetically pleasant environment for patients, staff, and visitors.” This policy did not clarify the separation of clean and dirty. The reference in the policy as follows: “Supplies or patient’s belongings should not be kept or stored behind the machine at the patient station. Clean supplies may not be kept under dirty sinks.” During an interview on 01/08/25 at 7:45 AM the Clinical Manager/Facility Administrator was asked if the facility had a policy for the separation of clean and dirty? The Clinical Manager/Facility Administrator confirmed he/she could not find any other policy. The Clinical Manager/Facility Administrator confirmed that patient’s personal belonging should not be placed on the clean supply counters.”

    Rule V0117. Standard-level.

  • Ic - Clean, Disinfect Surfaces & Equipment/Written Protocols

    The inspectors’ words, 540 words

    “IC-DISINFECT SURFACES/EQUIP/WRITTEN PROTOCOL CFR(s): 494.30(a)(4)(ii) [The facility must demonstrate that it follows standard infection control precautions by implementing- (4) And maintaining procedures, in accordance with applicable State and local laws and accepted public health procedures, for the-] (ii) Cleaning and disinfection of contaminated surfaces, medical devices, and equipment. This Standard is not met as evidenced by: 22198 Based on observations, interviews and policy review, the facility failed to ensure that staff followed the procedures for cleaning and disinfecting the dialysis machine after patient use for two of two dialysis machine cleaning observations (Stations #2 and #6). This failure has the potential for cross contamination and could negatively affect all 55 in-center dialysis patients. Findings include: During an observation on 01/06/25 at 10:39 AM, during Patient Care Technician (PCT) 2 was observed cleaning and disinfecting dialysis Station #2, in the dialysis machine side basket there was a second blood pressure (BP) cuff, which was not cleaned with the dialysis station. During an interview on 01/06/25 at 10:39 AM, PCT2 was asked if all equipment in dialysis Station #2 should be cleaned as a part of the dialysis station and pointed out the additional BP cuff in the dialysis machine basket, and PCT2 stated yes, the additional BP cuff in the dialysis machine basket should be cleaned as a part of the dialysis machine cleaning. During an observation on 01/07/25 at 10:40 AM, PCT1 was observed cleaning and disinfecting dialysis Station #6, in the dialysis machine side basket there were two additional BP cuffs, which were not cleaned with the dialysis station. During an interview on 01/07/25 10:40 AM, PCT1 was asked if all equipment in dialysis Station #6 should be cleaned as a part of the dialysis station and pointed out the two additional BP cuffs in the dialysis machine basket, and PCT1 stated, he/she thought the extra BP cuff stored on the dialysis machines only needed to be cleaned if they were used. PCT1 left dialysis Station #6 without cleaning the two additional BP cuffs and returned to start setting up the dialysis machine for the next patient. During an interview on 01/07/24 at 11:50 AM the Clinical Manager/Facility Administrator confirmed that if there were additional BP cuffs on a dialysis machine, they should be cleaned between patients. Review of the facility’s policy titled “Cleaning and Disinfecting the Dialysis Station” dated 09/05/23 revealed, “The Centers for Medicare and Medicaid Services (CMS) has regulations that in order to prevent cross contamination, a dialysis station must be cleaned and disinfected between dialysis patients. The chair and dialysis equipment are used by multiple patients during a treatment day, and it is critical that these items be thoroughly cleaned and disinfected between uses. Also, the nature of dialysis treatments with frequent exposure to blood and body fluids, close proximity of patients and staff, and the immunocompromised status of dialysis patients make dialysis a high-risk area for spreading infectious disease. ... Definition Dialysis Station: Area including the dialysis machine, chair/bed and other reusable equipment or supplies utilized during dialysis treatment, patient training, and/or patient clinic visits. Equipment in the dialysis station may include (but is not limited to) the following: o Dialysis machine cycler and attachments such as IV [intravenous] pole, BP cuff and ...””

    Rule V0122. Standard-level.

  • Appropriateness Of Dialysis Rx

    The inspectors’ words, 316 words

    “PA-APPROPRIATENESS OF DIALYSIS RX CFR(s): 494.80(a)(2) The patient’s comprehensive assessment must include, but is not limited to, the following: (2) Evaluation of the appropriateness of the dialysis prescription, This Standard is not met as evidenced by: 22198 Based on medical record reviews, interview, and policy review, the facility failed to follow the individualized dialysis (an artificial means of kidney function that removes the waste and excess fluid from the blood by passing through a filter) prescription as determined by the medical provider for one of five sampled in-center dialysis patients (P) (P3) in a total universe sample of nine. Failure to follow the medical providers’ dialysis prescription had the potential to negatively impact on the effectiveness of the prescribed dialysis treatments for all 55 patients receiving in-center dialysis treatments at this facility. Findings include: A review of P3’s electronic medical record (EMR) revealed a prescribed blood flow rate (BFR) of 500 milliliters per minute (ml/min). A review of two of six “Treatment Sheet” from 12/09/24 through 01/06/25, in the EMR indicated the following: a. On 12/09/23, the BFR was documented at 385 ml/min from 12:23 PM until 12:48 PM. b. On 01/06/25, the BFR was 300 ml/min from 11:18 AM until 12:04 PM. The BFR was documented at 440 ml/min from 12:04 PM for the remainder of the treatment at 3:21 PM. There was no documented rationale for the change to the prescribed BFR. During an interview on 01/08/25 at 8:00 AM the Clinical Manager/Facility Administrator confirmed the BFR for P3 was documented and not run as prescribed on 12/09/24 and 01/06/25, and the staff failed to document rationale for the change to the physician’s prescription. Review of the facility’s policy titled, “Patient Assessment and Monitoring,” dated 05/01/23, revealed, “Check machine settings and measurements: Check prescribed blood flow [BFR] is being achieved or reason is documented in medical record if unable to meet prescribed blood flow.””

    Rule V0503. Standard-level.

  • Vascular Access - Monitor/Referrals

    The inspectors’ words, 459 words

    “POC-VASCULAR ACCESS-MONITOR/REFERRALS CFR(s): 494.90(a)(5) The interdisciplinary team must provide vascular access monitoring and appropriate, timely referrals to achieve and sustain vascular access. The hemodialysis patient must be evaluated for the appropriate vascular access type, taking into consideration co-morbid conditions, other risk factors, and whether the patient is a potential candidate for arteriovenous fistula placement. This Standard is not met as evidenced by: 22198 Based on observations, interviews and policy review, the facility failed to ensure that two of two staff (Registered Nurse (RN) 2 and Patient Care Technician (PCT) 3) confirmed that hemostasis had been achieved and the bandaged were changed prior to patients (P) (P1 and P8) left the facility. Failure to change the pressure dressing and confirm that hemostasis was achieved puts all arteriovenous fistula (AVF) and arteriovenous graft (AVG) patients at risk for bleeding post dialysis after leaving the facility. Findings include: During an observation on 01/06/25 at 10:32 AM RN2 after removing the clamps placed over the pressure dressing where the needles were removed on P1, RN2 applied another folded gauze pad and additional tape without assessing if hemostasis had been achieved or applying clean new dressing over the needled insertion sites. During an interview on 01/06/25 at 10:32 AM RN2 stated “I should have checked the insertion sites and changed the dressing, but the patient (P1) doesn’t like to wait.” During an observation on 01/06/25 at 11:25 AM PCT3 was observed during AVF discontinuation for P8 after 10 minutes of P8 holding pressure to achieve hemostasis, checked the lower insertion site, and blood squirted out onto PCT3’s gown sleeve, gloves and front of the gown. PCT3 reapplied a pressure dressing and left the floor to change bloody gown and gloves. PCT3 returned to the floor within five minutes, applied a second gauze and additional tape without checking to see if hemostasis had been achieved. PCT3 did not or applying clean new dressing over the needled insertion sites. During an interview on 01/06/25 at 11:25 AM PCT3 confirmed that he/she did not re-check the site for the P8 and had just added extra gauze and tape. PCT3 confirmed the needle insertion site should have been checked to ensure the bleeding had stopped and then re-dressed with clean dressing before P8 left. During an interview on 01/07/25 at 3:00 PM after reviewing the facility policy, the Clinical Manager/Facility Administrator confirmed the staff should be assessing hemostasis and apply a clean dressing after hemostasis was achieved. Review of the facility’s policy titled, “Post Treatment Fistula Needle Removal,” dated 07/01/24, revealed, “Once hemostasis is achieved: Remove the gauze. Apply antibiotic cream if ordered by a physician. Place Band-Aid, adhesive dressing or gauze dressing secured with clean tape. ... Confirm the presence of a thrill after hemostasis is achieved.””

    Rule V0550. Standard-level.

  • Pt/Caregiver Demonstrated Comprehension Of Training

    The inspectors’ words, 417 words

    “H-PT/CAREGIVER DEMO COMPREHEND TRAINING CFR(s): 494.100(b)(1) The dialysis facility must - (1) Document in the medical record that the patient, the caregiver, or both received and demonstrated adequate comprehension of the training; This Standard is not met as evidenced by: 22198 Based on reviews of medical records, email and policy and interview, the facility failed to ensure that Home Training was completed for one of two Home Peritoneal Dialysis (PD) patients (Patient (P)7). This failure put all five Home PD patients at risk of not having complete and accurate training to verify they are competent to perform PD at home safely and effectively. Findings include: Review of P7’s medical record revealed that the Home Training “Readiness Assessment” used to verify P7 had received training and was capable to performing the Home PD tasks safely was dated on 11/03/22. Review of the assessment indicated P7 and facility staff including the Medical Director signed off P7 as competent to perform home PD however for 11 of 34 tasks on the “Readiness Assessment.” were documented as “not yet completed” During an interview of 01/07/25 at 8:00 AM during a review of the incomplete Home PD training for P7, the Clinical Manager/Facility Administrator confirmed that P7 was signed off as ready to perform Home PD, but the training was not complete. During an interview on 01/07/25 at 4:00 PM, Clinical Manager/Facility Administrator confirmed there was no additional training documented to ensure P6 had completed the entire “Home Training Program.” Clinical Manager/Facility Administrator stated that PD Home Training Registered Nurse (RN) 1 had sent an email confirming this information. Review of the email sent by PD Home Training RN1 dated 01/07/25 at 1:13 PM revealed “There is no more available documentation to me to Support P7’s training being further completed than what I submitted.” During a review of the facility’s policy titled “Home Dialysis Patient Education and Training” dated 02/06/23 revealed, “At the completion of the training program: The patient and/or care partner(s) must successfully demonstrate competency in clinical and technical procedures and self-care management. The qualified home therapies nurse must validate the patient and/or care partner competency including evaluating comprehension and skills. These requirements must be met prior to the patient care partner(s) being deemed competent to perform home dialysis independently. ... Documentation: Training treatments will be documented in the medical record. Training of required material must be documented in the patient medical record and must include evidence of patient/care partner(s) demonstrated comprehension and competence in performing the home dialysis procedures.””

    Rule V0586. Standard-level.

The one inspection in the last three years
Inspections on record
DateVisitWhat the record says
Jan 8, 2025Standard inspection6 deficiencies cited

Is it certified?

  • Medicare-certified dialysis facility, certified or last recertified on Feb 27, 2001.
  • Run for profit.
  • No deficiency on record in the last three years.
  • Chain: Fresenius Medical Care.
Source:

CMS, Dialysis Facility - Listing by Facility. Released Jul 15, 2026. Updated quarterly.

CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.

Has it been penalized?

  • CMS doesn’t publish fines or other penalties for dialysis facilities.
  • None of the deficiencies cited in the last three years came from an inspection that included a complaint investigation.
Source:

CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.

What does it offer?

  • Offers in-center hemodialysis, peritoneal dialysis and home hemodialysis training.
  • Doesn’t offer a shift starting at 5 p.m. or later.
  • 15 dialysis stations.
  • CMS doesn’t publish staffing levels for dialysis facilities.
Source:

CMS, Dialysis Facility - Listing by Facility and Patient survey (ICH CAHPS) - Facility. Released Jul 15, 2026. Updated quarterly.

Who owns it?

  • Part of the Fresenius Medical Care chain, as CMS lists it.
  • CMS publishes no owners file for dialysis facilities, so no other owner is named.
Source:

CMS, Dialysis Facility - Listing by Facility. Released Jul 15, 2026. Updated quarterly.

How do patients fare?

  • CMS rates it 3 of 5 stars (Jan 1, 2021 to Dec 31, 2024).
  • Compared by CMS with what it expects for the facility’s patients: patient survival, as expected; hospital admissions, as expected; readmissions to hospital, as expected; blood transfusions, as expected; emergency department visits, as expected; emergency department visits within 30 days of a hospital stay, as expected; bloodstream infections, better than expected; patients dialysing through a fistula, as expected; patients put on a kidney transplant waitlist in their first year of dialysis, as expected; patients on a kidney transplant waitlist, as expected.
  • CMS gives no : “Too few completed survey responses to report.”
Source:

CMS, Dialysis Facility - Listing by Facility and Patient survey (ICH CAHPS) - Facility. Released Jul 15, 2026. Updated quarterly.

Ratings and measures, as published
MeasureRating
Star ratingCMS’s star rating for dialysis facilities, 1 to 53 of 5
Patient survey ratingCMS star rating from its survey of the facility’s in-center hemodialysis patients (ICH CAHPS), 1 to 5Not rated

How does it compare nearby?

  • No other dialysis facility CMS lists is in Okanogan County.
Source:

CMS, Dialysis Facility - Listing by Facility. Released Jul 15, 2026. Updated quarterly.

What the record doesn’t say

  • CMS doesn’t publish fines or other penalties for dialysis facilities, so none are shown.
  • Only complaints that led to a citation appear; complaints that didn’t aren’t published.
  • QCOR says it has no dialysis inspection reports after February 19, 2026, while it moves to a new system: a later inspection is not shown yet.
  • CMS doesn’t publish staffing levels for dialysis facilities.
  • CMS publishes no owners file for dialysis facilities: the chain it lists is the only owner named.

Sources

If you believe something here is wrong, a correction starts with the agency whose record this copies: CMS. CMS’s own record is on Care Compare. If Hearth Record copied something wrongly, it will fix it and log the correction publicly, with its date: how corrections work.

Source:

This copy of the record was made on Oct 30, 2026.

From the facility

The public record above comes first. Anything the facility adds will appear here, below it, and say who wrote it.

Replies

None. Replies aren’t open yet. When they open, the facility will be able to answer any finding for free, and the reply will show beside that finding, unedited and dated.

Paid listing

None. Paid listings aren’t open yet. When they open, anything paid for will say “Paid by the facility”, and paying will never change a finding, a rating or the order of results.

How to read a record

Four things every record does, shown on an example record made up for this guide.

An example record, made up for this guide

An example nursing home

Made up for this guide: no real place is shown

Not fully inspected in over two years (CMS flag)

11 health citations at the latest inspection cycle

The state average is 14.3.

Source:

CMS, State and US Averages and Health Deficiencies. Released Oct 28, 2026. Updated monthly.

From the homeNone yet. Replies and paid listings aren’t open, and when they open they will sit here, below the record.

1 of 4

Every fact names its source.

Who published it, when, and how often it changes sit beside each fact, with a link to the agency’s own file.

Sign in

A free account keeps your watch list, shortlists, comparisons and saved searches on every device, and can email you when something you watch changes. Browsing never needs one.