Fresenius Kidney Care South Roanoke

A dialysis facility in Roanoke, Virginia 24014

117 Duke Gloucester Street SW, Roanoke, Virginia 24014. (540) 682-7250.

CMS’s own record, on Care Compare

Watch and the shortlist are kept with a free account, on every device. Your watch list. CMS’s own record is on Care Compare.

The short answer

Record last released by CMS on Oct 28, 2026.

The last 24 months 7 deficiencies in 1 month of the last 36. Last cited Apr 2024. Most serious: Standard-level. Every month

Each figure’s source sits beside it, in its section below.

What these words mean3
Star ratings
CMS rates some kinds of place from 1 to 5 stars, more stars meaning better on CMS’s own measures for that kind: for a nursing home, its health inspections, staffing and quality measures. A rating is CMS’s summary of those measures; it doesn’t promise good care. Source: CMS, Care Compare and the Five-Star Quality Rating System.
Inspection (survey)
A visit by state inspectors, often unannounced, who check a place against the rules it must meet. For nursing homes and other places Medicare pays, CMS calls these visits surveys: a standard survey of a nursing home comes at least every 15 months, and a complaint survey whenever a complaint calls for one. Source: CMS; 42 CFR 488.308.
Deficiency, citation, violation
What inspectors write up when a place didn’t meet a rule: the rule, what they saw, and when. CMS calls it a deficiency; states may say citation or violation. It is the inspectors’ finding, not a court’s, and the place is usually asked for a plan to correct it. Source: CMS, statement of deficiencies (Form CMS-2567); each state’s licensing agency.

What did inspectors find?

The last inspection on record was on Apr 23, 2024: a standard inspection.

7 deficiencies cited in the last three years.

Source:

CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.

When those deficiencies happened

7 deficiencies in 1 month of the last 36. Last cited Apr 2024. Most serious: Standard-level. The last 3 years, to Oct 30, 2026.

7 deficiencies by month over the last 3 years. Each cell is one month.
JanFebMarAprMayJunJulAugSepOctNovDec
2023 NovDec
2024 JanFebMarAprMayJunJulAugSepOctNovDec
2025 JanFebMarAprMayJunJulAugSepOctNovDec
2026 JanFebMarAprMayJunJulAugSepOct

Hover or focus a month to read it.

No visit on record Visited, nothing cited A stronger orange is more serious, on its source’s own levels, read onto four bands: from the least serious it publishes to the most
Source:

Hearth Record drew this from the dates and levels in the source’s own records.

Each deficiency, as cited

Rule titles as CMS’s inspectors cite them, set in sentence case.

Source:

CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.

Apr 23, 2024: standard inspection7 deficiencies
  • Ic - Clean/Dirty Areas, Med Prep Area, No Common Med Carts

    The inspectors’ words, 344 words

    “IC-CLEAN/DIRTY;MED PREP AREA;NO COMMON CARTS CFR(s): 494.30(a)(1)(i) Clean areas should be clearly designated for the preparation, handling and storage of medications and unused supplies and equipment. Clean areas should be clearly separated from contaminated areas where used supplies and equipment are handled. Do not handle and store medications or clean supplies in the same or an adjacent area to that where used equipment or blood samples are handled. When multiple dose medication vials are used (including vials containing diluents), prepare individual patient doses in a clean (centralized) area away from dialysis stations and deliver separately to each patient. Do not carry multiple dose medication vials from station to station. Do not use common medication carts to deliver medications to patients. If trays are used to deliver medications to individual patients, they must be cleaned between patients. This Standard is not met as evidenced by: 19883 Based on observation, interview, and review of facility policy, the facility failed to ensure that clean patient care areas were not contaminated by used equipment. The findings included: On 04/22/24 at approximately 3:45 PM a cell phone was observed laying on the medication preparation counter in the patient care area of the facility. On 4/22/24 at approximately 4:30 PM Staff Member #1 was asked by the Surveyor if cell phones were allowed in the patient care area. Staff Member #1 stated that cell phones are allowed in the patient care area only if they are assigned to a staff member by the facility, for work use. On 4/23/24 at approximately 4:30 PM, Staff Member #1 verified that the cell phone observed on the medication preparation area was a staff member’s personal cell phone, and therefore should not have been in the patient care area. Review of the facility’s policy titled: “Use of Portable Electronic Communication Devices,” Effective Date: 12/15/20, read in part: “...Patient care employees are prohibited from carrying cell phones and portable communication devices into patient care areas...” The findings were discussed with Staff Member’s #1, #2, #3, #8, #9, #10, and #11 on 4/23/24 at 1:00 PM.”

    Rule V0117. Standard-level.

  • Ic - Clean, Disinfect Surfaces & Equipment/Written Protocols

    The inspectors’ words, 270 words

    “IC-DISINFECT SURFACES/EQUIP/WRITTEN PROTOCOL CFR(s): 494.30(a)(4)(ii) [The facility must demonstrate that it follows standard infection control precautions by implementing- (4) And maintaining procedures, in accordance with applicable State and local laws and accepted public health procedures, for the-] (ii) Cleaning and disinfection of contaminated surfaces, medical devices, and equipment. This Standard is not met as evidenced by: 46466 Based on observations and facility document review, it was determined that the facility’s staff failed to clean and disinfect contaminated surfaces of the medical devices and equipment per policy. The findings included: On 4/22/24 at 3:20 p.m. and 3:30 p.m., Staff Member #12 was observed disinfecting patient stations #6 and #8. Staff Member #12 did not remove the prime waste buckets and didn’t disinfect them at either station. Staff Member # 12 also failed to fold the chairside tray tables down at either station to disinfect the areas between the arm of the chair and the tray tables. On 4/22/24 at 3:55 p.m., Staff Member #5 was observed disinfecting patient station #11. Staff Member #5 did not fold the chairside tray tables down to disinfect the areas between the arm of the chair and the table. A review of the facility’s policy “Cleaning and Disinfecting the Dialysis Station”, published 9/5/23, stated in part: “...Procedure...3. Use a cloth wetted with 1:100 bleach solution or EPA- approved disinfectant to clean and disinfect the dialysis station (chair/bed, tables, machine, television, IV pole, B/P cuff, hand sanitizer dispenser and holder, chaise wall behind chair)...4. Clean all surfaces...”. The findings were discussed with Staff Members #1, #2, #3, #8, #9, #10 and #11 on 4/23/24 at 1:00 p.m.”

    Rule V0122. Standard-level.

  • Ic - Staff Education Re Catheters/Catheter Care

    The inspectors’ words, 323 words

    “IC-STAFF EDUCATION-CATHETERS/CATHETER CARE CFR(s): 494.30(a)(2) Recommendations for Placement of Intravascular Catheters in Adults and Children I. Health care worker education and training A. Educate health-care workers regarding the ... appropriate infection control measures to prevent intravascular catheter-related infections. B. Assess knowledge of and adherence to guidelines periodically for all persons who manage intravascular catheters. II. Surveillance A. Monitor the catheter sites visually of individual patients. If patients have tenderness at the insertion site, fever without obvious source, or other manifestations suggesting local or BSI [blood stream infection], the dressing should be removed to allow thorough examination of the site. Central Venous Catheters, Including PICCs, Hemodialysis, and Pulmonary Artery Catheters in Adult and Pediatric Patients. VI. Catheter and catheter-site care B. Antibiotic lock solutions: Do not routinely use antibiotic lock solutions to prevent CRBSI [catheter related blood stream infections]. This Standard is not met as evidenced by: 46466 Based on observations and document review, the facility staff failed to maintain aseptic technique for a CVC (central venous catheter) dressing change. The findings include: On 4/22/24 at 4:10 p.m., Staff Member #12 was observed performing CVC exit site care at patient station #8. First, Staff Member #12 cleansed the area around the exit site with antiseptic. After disinfecting the exit site, the patient decided to remove their sweatshirt. While wearing gloves, Staff Member #12 assisted the patient with the removal of their clothing. During the clothing removal, the patient’s personal medication fell onto the floor. Staff Member #12 picked the medication off the floor and set it on the patient’s tray table. Staff Member #12 did not remove their contaminated gloves before recleansing the exit site area again. A review of the facility’s policy “Changing the Catheter Dressing Procedure”, published 2/5/24, stated in part: “...Cleaning the Site...Step 1. Perform hand hygiene and don clean gloves...”. The findings were discussed with Staff Members #1, #2, #3, #8, #9, #10 and #11 on 4/23/24 at 1:00 p.m.”

    Rule V0147. Standard-level.

  • Carbon Adsorption - Monitoring, Testing Frequency

    The inspectors’ words, 366 words

    “CARBON ADSORP-MONITOR, TEST FREQUENCY CFR(s): 494.40(a) 6.2.5 Carbon adsorption: monitoring, testing freq Testing for free chlorine, chloramine, or total chlorine should be performed at the beginning of each treatment day prior to patients initiating treatment and again prior to the beginning of each patient shift. If there are no set patient shifts, testing should be performed approximately every 4 hours. Results of monitoring of free chlorine, chloramine, or total chlorine should be recorded in a log sheet. Testing for free chlorine, chloramine, or total chlorine can be accomplished using the N.N-diethyl-p-phenylene-diamine (DPD) based test kits or dip-and-read test strips. On-line monitors can be used to measure chloramine concentrations. Whichever test system is used, it must have sufficient sensitivity and specificity to resolve the maximum levels described in [AAMI] 4.1.1 (Table 1) [which is a maximum level of 0.1 mg/L]. Samples should be drawn when the system has been operating for at least 15 minutes. The analysis should be performed on-site, since chloramine levels will decrease if the sample is not assayed promptly. This Standard is not met as evidenced by: 19883 Based on observation, interview and facility document review, it was determined that the facility failed to ensure that chlorine and pH test strips were labeled per facility policy. The findings included: On 4/22/24 at approximately 1:30 PM two surveyors observed one (1) bottle of chlorine test strips, and at least three (3) pH test strip bottles in the patient care area. All observed bottles were not labeled with the date the bottles were opened nor with the initials of the staff member who opened them. The findings were discussed with Staff Member #1 on 4/22/24 at approximately 5:00 PM. Staff Member #1 stated that the bottles should have had a date of opening, and staff initials on the bottles. Staff Member #1 also provided a copy of a facility document dated 1/5/17, and titled: “Test Strips and Solutions.” The document read in part: “Please be aware ALL test strip and solutions must be dated and initialed when first opened (on the side of the bottle)...” The findings were discussed with Staff Member’s #1, #2, #3, #8, #9, #10, and #11, on 4/24/24 at 1:00 PM.”

    Rule V0196. Standard-level.

  • Manage Volume Status

    The inspectors’ words, 357 words

    “POC-MANAGE VOLUME STATUS CFR(s): 494.90(a)(1) The plan of care must address, but not be limited to, the following: (1) Dose of dialysis. The interdisciplinary team must provide the necessary care and services to manage the patient’s volume status; This Standard is not met as evidenced by: 46466 Based on clinical record and facility document review, the facility staff failed to assess patients during treatment per facility policy three (3) of four (4) patients included in the survey sample. The findings included: Four (4) sampled patient records were reviewed on 4/24/24. Patient #3: Six (6) treatment records from 4/8/24 through 4/19/24 were reviewed. On 4/8/24, Patient #3’s blood pressure and pulse were documented at 2:01 p.m. and not documented again until 4:26 p.m. On 4/12/24, Patient #3’s blood pressure and pulse were documented at 2:32 p.m. and not documented again until 3:36 p.m. On 4/15/24, Patient #3’s blood pressure and pulse were documented at 2:04 p.m. and not documented again until 3:00 p.m. and not documented again until 4:05 p.m. On 4/19/24, Patient #3’s blood pressure and pulse were documented at 2:04 p.m. and not documented again until after treatment ended at 4:33 p.m. Patient #5: Six (6) treatment records were reviewed from 4/8/24 through 4/19/24. On 4/10/24, Patient #5’s blood pressure and pulse were documented at 6:30 p.m. and not documented again until 7:38 p.m. On 4/12/24, Patient #5’s blood pressure and pulse were documented at 3:48 p.m. and not documented again until 5:03 p.m. On 4/15/24, Patient #5’s blood pressure and pulse were documented at 5:30 p.m. and not documented again until 6:34 p.m. Patient #6: Five (5) treatment records were reviewed from 4/8/24 through 4/19/24. On 4/12/24, Patient #6’s blood pressure and pulse were documented at 5:06 p.m. and not documented again until 6:02 p.m. A review of the facility’s policy “Patient Assessment and Monitoring”, published 5/1/23, stated in part: “...During Treatment: Obtain blood pressure and pulse rate every 30 minutes or more as needed but not to exceed 45 minutes or per state regulations...”. The findings were discussed with Staff Members #1, #2, #3, #8, #9, #10 and #11 on 4/23/24 at 1:00 p.m.”

    Rule V0543. Standard-level.

  • Achieve Adequate Clearance

    The inspectors’ words, 235 words

    “POC-ACHIEVE ADEQUATE CLEARANCE CFR(s): 494.90(a)(1) Achieve and sustain the prescribed dose of dialysis to meet a hemodialysis Kt/V of at least 1.2 and a peritoneal dialysis weekly Kt/V of at least 1.7 or meet an alternative equivalent professionally-accepted clinical practice standard for adequacy of dialysis. This Standard is not met as evidenced by: 46466 Based on medical record and facility document review, the facility staff failed to follow physician’s orders for the prescribed dose of dialysis BFR (blood flow rate) for one (1) of three (3) in-center dialysis patients included in the sample. The findings included: The surveyor reviewed five (5) dialysis treatment records for Patient #6: from 4/8/24 through 4/19/24. The treatment sheets evidenced an order for a BFR of 400. On 4/8/24, the BFR was documented as 350. On 4/10/24, the BFR was documented as 350. On 4/15/24, the BFR was documented as 350. Patient #6’s clinical record failed to contain evidence of documentation explaining why the BFR was not being administered as prescribed. A review of the facility’s policy “Patient Assessment and Monitoring”, published 5/1/23, stated in part: “...3. Machine Parameters and Extracorpeal Circuit - Check machine settings and measurements: Check prescribed blood flow is being achieved or reason is documented in the medical record if unable to meet prescribed blood flow...”. The findings were discussed with Staff Members #1, #2, #3, #8, #9, #10 and #11 on 4/23/24 at 1:00 p.m.”

    Rule V0544. Standard-level.

  • Vascular Access - Monitor/Referrals

    The inspectors’ words, 215 words

    “POC-VASCULAR ACCESS-MONITOR/REFERRALS CFR(s): 494.90(a)(5) The interdisciplinary team must provide vascular access monitoring and appropriate, timely referrals to achieve and sustain vascular access. The hemodialysis patient must be evaluated for the appropriate vascular access type, taking into consideration co-morbid conditions, other risk factors, and whether the patient is a potential candidate for arteriovenous fistula placement. This Standard is not met as evidenced by: 46466 Based on observations, interview and facility document review, facility staff failed to care for a patient’s arteriovenous (AV) graft/fistula according to the facility’s policy. Facility staff utilized two (2) clamps simultaneously on one (1) patient to achieve hemostasis post cannulation. The findings included: On 4/23/24 at 3:50 p.m., the surveyors observed Patient #1 at station #11 with two (2) clamps over their AV fistula/graft site on their left arm. In an interview with Staff Member #1 on 4/24/24 at 11:55 a.m., Staff Member #1 confirmed that Patient #1 did not have a medical order for placing two (2) AV graft/fistula clamps post cannulation. A review of the facility’s policy “Venipuncture Site Clamps”, published 7/5/22, stated in part: “...Use only one clamp at a time to prevent excessive pressure which can cause thrombosis...”. The findings were discussed with Staff Members #1, #2, #3, #8, #9, #10 and #11 on 4/23/24 at 1:00 p.m.”

    Rule V0550. Standard-level.

The one inspection in the last three years
Inspections on record
DateVisitWhat the record says
Apr 23, 2024Standard inspection7 deficiencies cited

Is it certified?

  • Medicare-certified dialysis facility, certified or last recertified on Jul 11, 2018.
  • Run for profit.
  • No deficiency on record in the last three years.
  • Chain: Fresenius Medical Care.
Source:

CMS, Dialysis Facility - Listing by Facility. Released Jul 15, 2026. Updated quarterly.

CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.

Has it been penalized?

  • CMS doesn’t publish fines or other penalties for dialysis facilities.
  • None of the deficiencies cited in the last three years came from an inspection that included a complaint investigation.
Source:

CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.

What does it offer?

  • Offers in-center hemodialysis and peritoneal dialysis.
  • Doesn’t offer home hemodialysis training and a shift starting at 5 p.m. or later.
  • 13 dialysis stations.
  • CMS doesn’t publish staffing levels for dialysis facilities.
Source:

CMS, Dialysis Facility - Listing by Facility and Patient survey (ICH CAHPS) - Facility. Released Jul 15, 2026. Updated quarterly.

Who owns it?

  • Part of the Fresenius Medical Care chain, as CMS lists it.
  • CMS publishes no owners file for dialysis facilities, so no other owner is named.
Source:

CMS, Dialysis Facility - Listing by Facility. Released Jul 15, 2026. Updated quarterly.

How do patients fare?

  • CMS rates it 3 of 5 stars (Jan 1, 2021 to Dec 31, 2024).
  • Compared by CMS with what it expects for the facility’s patients: patient survival, as expected; hospital admissions, as expected; readmissions to hospital, as expected; blood transfusions, as expected; emergency department visits, as expected; emergency department visits within 30 days of a hospital stay, as expected; bloodstream infections, as expected; patients dialysing through a fistula, as expected; patients put on a kidney transplant waitlist in their first year of dialysis, as expected; patients on a kidney transplant waitlist, as expected.
  • CMS gives no : “Too few completed survey responses to report.”
Source:

CMS, Dialysis Facility - Listing by Facility and Patient survey (ICH CAHPS) - Facility. Released Jul 15, 2026. Updated quarterly.

Ratings and measures, as published
MeasureRating
Star ratingCMS’s star rating for dialysis facilities, 1 to 53 of 5
Patient survey ratingCMS star rating from its survey of the facility’s in-center hemodialysis patients (ICH CAHPS), 1 to 5Not rated

How does it compare nearby?

  • Of the 4 dialysis facilities CMS lists in Roanoke City, 4 have a star rating from CMS: 3 rated 3 of 5, 1 rated 2 of 5.
  • CMS rates this one 3 of 5.
Source:

CMS, Dialysis Facility - Listing by Facility. Released Jul 15, 2026. Updated quarterly.

What the record doesn’t say

  • CMS doesn’t publish fines or other penalties for dialysis facilities, so none are shown.
  • Only complaints that led to a citation appear; complaints that didn’t aren’t published.
  • QCOR says it has no dialysis inspection reports after February 19, 2026, while it moves to a new system: a later inspection is not shown yet.
  • CMS doesn’t publish staffing levels for dialysis facilities.
  • CMS publishes no owners file for dialysis facilities: the chain it lists is the only owner named.

Sources

If you believe something here is wrong, a correction starts with the agency whose record this copies: CMS. CMS’s own record is on Care Compare. If Hearth Record copied something wrongly, it will fix it and log the correction publicly, with its date: how corrections work.

Source:

This copy of the record was made on Oct 30, 2026.

From the facility

The public record above comes first. Anything the facility adds will appear here, below it, and say who wrote it.

Replies

None. Replies aren’t open yet. When they open, the facility will be able to answer any finding for free, and the reply will show beside that finding, unedited and dated.

Paid listing

None. Paid listings aren’t open yet. When they open, anything paid for will say “Paid by the facility”, and paying will never change a finding, a rating or the order of results.

How to read a record

Four things every record does, shown on an example record made up for this guide.

An example record, made up for this guide

An example nursing home

Made up for this guide: no real place is shown

Not fully inspected in over two years (CMS flag)

11 health citations at the latest inspection cycle

The state average is 14.3.

Source:

CMS, State and US Averages and Health Deficiencies. Released Oct 28, 2026. Updated monthly.

From the homeNone yet. Replies and paid listings aren’t open, and when they open they will sit here, below the record.

1 of 4

Every fact names its source.

Who published it, when, and how often it changes sit beside each fact, with a link to the agency’s own file.

Sign in

A free account keeps your watch list, shortlists, comparisons and saved searches on every device, and can email you when something you watch changes. Browsing never needs one.