Hearth Record

Davita Stone Ridge Dialysis

A dialysis facility in Chantilly, Virginia 20152

24640 Southpoint Drive, Suite 160, Chantilly, Virginia 20152. (703) 327-4357.

CMS’s own record, on Care Compare

Watch and the shortlist are kept with a free account, on every device. Your watch list. CMS’s own record is on Care Compare.

The short answer

Record last released by CMS on Oct 28, 2026.

The last 24 months 4 deficiencies in 1 month of the last 36. Last cited Jun 2024. Most serious: Standard-level. Every month

Each figure’s source sits beside it, in its section below.

What these words mean3
Star ratings
CMS rates some kinds of place from 1 to 5 stars, more stars meaning better on CMS’s own measures for that kind: for a nursing home, its health inspections, staffing and quality measures. A rating is CMS’s summary of those measures; it doesn’t promise good care. Source: CMS, Care Compare and the Five-Star Quality Rating System.
Inspection (survey)
A visit by state inspectors, often unannounced, who check a place against the rules it must meet. For nursing homes and other places Medicare pays, CMS calls these visits surveys: a standard survey of a nursing home comes at least every 15 months, and a complaint survey whenever a complaint calls for one. Source: CMS; 42 CFR 488.308.
Deficiency, citation, violation
What inspectors write up when a place didn’t meet a rule: the rule, what they saw, and when. CMS calls it a deficiency; states may say citation or violation. It is the inspectors’ finding, not a court’s, and the place is usually asked for a plan to correct it. Source: CMS, statement of deficiencies (Form CMS-2567); each state’s licensing agency.

What did inspectors find?

The last inspection on record was on Jun 4, 2024: a standard inspection.

4 deficiencies cited in the last three years.

Source:

CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.

When those deficiencies happened

4 deficiencies in 1 month of the last 36. Last cited Jun 2024. Most serious: Standard-level. The last 3 years, to Oct 30, 2026.

4 deficiencies by month over the last 3 years. Each cell is one month.
JanFebMarAprMayJunJulAugSepOctNovDec
2023 NovDec
2024 JanFebMarAprMayJunJulAugSepOctNovDec
2025 JanFebMarAprMayJunJulAugSepOctNovDec
2026 JanFebMarAprMayJunJulAugSepOct

Hover or focus a month to read it.

No visit on record Visited, nothing cited A stronger orange is more serious, on its source’s own levels, read onto four bands: from the least serious it publishes to the most
Source:

Hearth Record drew this from the dates and levels in the source’s own records.

Each deficiency, as cited

Rule titles as CMS’s inspectors cite them, set in sentence case.

Source:

CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.

Jun 4, 2024: standard inspection4 deficiencies
  • Ic - Wear Gloves/Hand Hygiene

    The inspectors’ words, 295 words

    “IC-WEAR GLOVES/HAND HYGIENE CFR(s): 494.30(a)(1) Wear disposable gloves when caring for the patient or touching the patient’s equipment at the dialysis station. Staff must remove gloves and wash hands between each patient or station. This Standard is not met as evidenced by: 49355 Based on four (4) infection control observations, interviews, and document review, it was determined that the staff failed to conduct hand hygiene to prevent the spread of infections diseases. The findings include: On 06/03/2024 at 10:50 a.m., Staff Member #7 was deaccessing Patient #2’s fistula at station #5. The Staff Member failed to perform hand hygiene several times before donning a new pair of gloves. At 12:11 p.m., Staff Member #7 was accessing a fistula on Patient #11 at station #8. The Staff Member did not perform hand hygiene numerous times before donning new gloves. At 1:36 p.m., Staff Member #7 at station #4 with Patient #6 failed to perform hand hygiene on several occasions before donning a new pair of gloves. On 06/04/2024 at 11:05 a.m., Staff Member #13 was deaccessing Patient #13 at station #10. The Staff Member did not perform hand hygiene several times before donning fresh gloves. In a meeting with Staff Members # 1, 12 and 15 at 4:22 p.m. on 06/03/2024, there was agreement by all that hand hygiene should always be performed when removing soiled gloves and before donning new gloves. A review of the facility’s document entitled, “Infection Control For Dialysis Facilities,” policy: 1-05-01, revision date April 2023, reads, in part: ... “Hand Hygiene 1. All teammates, Physicians and Non-Physician (NPP) will perform hand hygiene ... b. prior to gloving and immediately after removal of gloves” The above concerns were discussed at the exit conference on 06/04/2024 with Staff Members #1, 8 and 12.”

    Rule V0113. Standard-level.

  • Ic - Aseptic Techniques For Iv Meds

    The inspectors’ words, 192 words

    “IC-ASEPTIC TECHNIQUES FOR IV MEDS CFR(s): 494.30(b)(2) [The facility must-] (2) Ensure that clinical staff demonstrate compliance with current aseptic techniques when dispensing and administering intravenous medications from vials and ampules; and This Standard is not met as evidenced by: 49355 Based on observations and document review, it was determined the facility staff failed to ensure aseptic technique when preparing intravenous (IV) medications in one (1) out of two (2) observations. The findings include: On 06/04/2024 at 11:13 a.m., this surveyor observed Staff Member #14 drawing up two (2) syringes of heparin from a 30 milliliter (ml) multidose vial. The staff member cleaned the rubber stopper of the vial and withdrew the desired amount into the first syringe. The Staff Member did not clean the stopper again with a new alcohol wipe before withdrawing the desired volume of heparin into the second syringe. A review of the facility’s policy entitled, “Medication Policy,” policy #1-06-01, revision date October 2023, reads, in part: ... “21. An aseptic environment and aseptic technique is used when preparing medications.” The above observation was discussed at the exit conference on 06/04/2024 with Staff Members #1, 8 and 12.”

    Rule V0143. Standard-level.

  • Manage Volume Status

    The inspectors’ words, 1,003 words

    “POC-MANAGE VOLUME STATUS CFR(s): 494.90(a)(1) The plan of care must address, but not be limited to, the following: (1) Dose of dialysis. The interdisciplinary team must provide the necessary care and services to manage the patient’s volume status; This Standard is not met as evidenced by: 49355 Based on medical record reviews, interviews and document review, it was determined the facility staff failed to document deviations in target weight (TW) versus post treatment weight (PTW) (+/- 1kg) and pulse (P) readings that were not within facility guidelines in four (4) out of four (4) in-center hemodialysis patient flow sheets reviewed and failed to complete pre-treatment nursing assessments within one (1) hour of the dialysis start time in four (4) out of four (4) patient flow sheets reviewed. The findings include: The six (6) most recent flow sheets for each of four (4) sampled in-center hemodialysis patients were reviewed on 06/03/2024. Patient #2: On treatment date 05/20/2024, the patient’s P ranged from 48 beats per minute (bpm) to 56 bpm during the entire 3.5 hour treatment. There was no documentation on the flow sheet as to whether the technician or the charge nurse were aware of the deviation. On 05/22/2024, the patient’s P ranged from 42 (bpm) to 55 (bpm) throughout the entire 3.5 hour treatment. There was no documentation on the flow sheet as to whether the technician or the charge nurse were aware of the deviation. On 05/24/2024, the patient’s P ranged from 50 (bpm) to 56 (bpm) throughout the entire 3.5 hour treatment. There was no documentation on the flow sheet as to whether the technician or the charge nurse were aware of the deviation. On 05/27/2024, the patient’s P ranged from 54 (bpm) to 59 (bpm) throughout the entire 3.5 hour treatment. There was no documentation on the flow sheet as to whether the technician or the charge nurse were aware of the deviation. The patient’s treatment began at 7:37 a.m. The pre-treatment nursing assessment wasn’t completed until 9:58 a.m. On 05/29/2024, the patient’s P ranged from 41 (bpm) to 59 (bpm) throughout the entire 3.5 hour treatment. There was no documentation on the flow sheet as to whether the technician or the charge nurse were aware of the deviation. On 05/31/2024, the patient’s P ranged from 50 (bpm) to 55 (bpm) throughout the entire 3.5 hour treatment. There was no documentation on the flow sheet as to whether the technician or the charge nurse were aware of the deviation. Patient #5: On 05/23/2024, the patient’s treatment started at 7:23 a.m. The pre-treatment nursing assessment wasn’t completed until 8:26 a.m. On 05/24/2024, the patient’s PTW was 56.9 kilograms (kg) as compared to the TW of 58 kg, a deviation of 1.1 kg. There was no documentation in the treatment note acknowledging the variance. On 05/25/2024, the patient’s PTW was 56.7 kg as compared to the TW of 58 kg, a deviation of 1.3 kg. There was no documentation in the treatment note acknowledging the variance. On 05/27/2024, the patient’s treatment started at 7:36 a.m. The pre-treatment nursing assessment wasn’t completed until 10:10 a.m. On 05/30/2024, the patient’s treatment started at 8:00 a.m. The pre-treatment nursing assessment wasn’t completed until 9:23 a.m. Patient #6: On 05/20/2024, the patient’s PTW was 61.8 kg as compared to the TW of 59 kg, a deviation of 2.8 kg. There was no documentation in the treatment note acknowledging the variance. On 05/22/2024, the patient’s PTW was 62.1 kg as compared to the TW of 60 kg, a deviation of 2.1 kg. There was no documentation in the treatment note acknowledging the variance. On 05/27/2024, the patient’s treatment started at 12:40 p.m. The pre-treatment nursing assessment wasn’t completed until 1:51 p.m. The patient’s PTW was 62.3 kg as compared to the TW of 60 kg, a deviation of 2.3 kg. There was no documentation in the treatment note acknowledging the variance. On 05/29/2024, the patient’s PTW was 61.8 kg as compared to the TW of 60 kg, a deviation of 1.8 kg. There was no documentation in the treatment note acknowledging the variance. On 05/31/2024, the patient’s PTW was 61.7 kg as compared to the TW of 60 kg, a deviation of 1.7 kg. There was no documentation in the treatment note acknowledging the variance. Patient #7: On 05/20/2024, the patient’s treatment started at 12:26 p.m. The pre-treatment nursing assessment wasn’t completed until 1:37 p.m. The patient’s PTW was 80.0 kg as compared to the TW of 81.5 kg, a deviation of 1.5 kg. There was no documentation in the treatment note acknowledging the variance. On 05/27/2024, the patient’s treatment started at 12:21 p..m. The pre-treatment nursing assessment wasn’t completed until 1:41 p.m. In interviews with Staff Members #4 and 5, both said that parameters outside of facility guidelines should be documented on the flow sheets and the charge nurse should be notified of any variances. Staff Member #4 also stated that pre-treatment nursing assessments should be completed within one (1) hour of treatment initiation. A review of the facility’s policy entitled, “Pre-Intra-Post Treatment Data Collection, Monitoring and Nursing Assessment,” policy #1-03=08, revision date April 2024, reads, in part: ... “Intradialytic Collection/Assessment ... 8. The licensed nurse will round on those patients without reported abnormal findings and complete the nursing assessment within one (1) hour of dialysis treatment initiation... ... 11. Abnormal findings, interventions and patient response will be documented in the patient’s medical record... ... Abnormal Findings ... the following are considered abnormal findings and should be reported to the licensed nurse and documented in the patient’s medical record. ... Members of the patient care team should report ANY changes in patient condition or concerns of patient well-being immediately to the licensed nurse at any time. ... Fluid Status: ... Post-treatment: ... If patient is above or below 1 kg from the target weight ... Heart or Pulse Rate Pre/Intra/Post: ... Less than 60 beats per minutes.... The above findings were discussed at the exit conference on 06/04/2024 with Staff Members #1, 8 and 12.”

    Rule V0543. Standard-level.

  • Vascular Access - Monitor/Referrals

    The inspectors’ words, 456 words

    “POC-VASCULAR ACCESS-MONITOR/REFERRALS CFR(s): 494.90(a)(5) The interdisciplinary team must provide vascular access monitoring and appropriate, timely referrals to achieve and sustain vascular access. The hemodialysis patient must be evaluated for the appropriate vascular access type, taking into consideration co-morbid conditions, other risk factors, and whether the patient is a potential candidate for arteriovenous fistula placement. This Standard is not met as evidenced by: 49355 Based on three (3) observations, interviews and document review, it was determined the facility staff failed to aseptically access an arteriovenous (AV) graft/fistulas and failed to properly use clamps designed for hemostasis. The findings include: At 12:05 p.m. on 06/03/2024, this surveyor returned to the treatment floor. At that time, Patient #5 at station #4 in Staff Member #6’s area, had a clamp in place on the left arm, over a AV site that had been deaccessed. When the surveyor exited the treatment floor at 12:40 p.m., the clamp was still in place. At that time, the clamp had been observed in use for thirty-five (35) minutes. At 12:11 p.m., Staff Member #7 was cleansing the fistula site in preparation for access on Patient #11 at station #8. The Staff Member palpated the site and then accessed the site with the cannulation needles, without cleaning the area again. At 12:36 p.m., this surveyor observed Staff Member #6 cleansing the AV site of Patient #12 at station #3. The Staff Member palpated the cleansed site and then accessed the site, without cleaning the site again. In a discussion at 4:22 p.m. on 06/03/2024, Staff Members #1, 12 and 15 agreed that the AV sites should have been cleansed again with antiseptic before cannulating and that the usage of a clamp for that duration was not within the facility’s policy guidelines. A review of the facility’s policy entitled, “AV Fistula or Graft Cannulation with Nipro or Medicsystems Safety Fistula Needles (SFN) and Administration of Heparin Loading Dose, policy #1-04-01E, revision date October 2022, reads, in part:... “Procedure... ... 8. Locate and palpate the needle cannulation sites prior to skin preparation. ... 13. Do not palpate insertion site once area has been prepped. Once the access site has been prepped, touching it will contaminate the site and possibly allow for the introduction of bacteria during cannulation.” A facility policy entitled, “Utilizing Vascular Access Clamps,” policy # 1-04-08, revision April 2019, states, in part:... “Policy: ... 3. Vascular access clamps should not be used routinely. However, if a patient is unable to hold his/her own sites, it is recommended that only one (1) clamp is used at a times and should not be left on longer than 20 minutes.” The above concerns were discussed with Staff Members #1, 8 and 12 at the exit conference on 06/04/2024.”

    Rule V0550. Standard-level.

The one inspection in the last three years
Inspections on record
DateVisitWhat the record says
Jun 4, 2024Standard inspection4 deficiencies cited

Is it certified?

  • Medicare-certified dialysis facility, certified or last recertified on Mar 7, 2018.
  • Run for profit.
  • No deficiency on record in the last three years.
  • Chain: DaVita.
Source:

CMS, Dialysis Facility - Listing by Facility. Released Jul 15, 2026. Updated quarterly.

CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.

Has it been penalized?

  • CMS doesn’t publish fines or other penalties for dialysis facilities.
  • None of the deficiencies cited in the last three years came from an inspection that included a complaint investigation.
Source:

CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.

What does it offer?

  • Offers in-center hemodialysis and peritoneal dialysis.
  • Doesn’t offer home hemodialysis training and a shift starting at 5 p.m. or later.
  • 13 dialysis stations.
  • CMS doesn’t publish staffing levels for dialysis facilities.
Source:

CMS, Dialysis Facility - Listing by Facility and Patient survey (ICH CAHPS) - Facility. Released Jul 15, 2026. Updated quarterly.

Who owns it?

  • Part of the DaVita chain, as CMS lists it.
  • CMS publishes no owners file for dialysis facilities, so no other owner is named.
Source:

CMS, Dialysis Facility - Listing by Facility. Released Jul 15, 2026. Updated quarterly.

How do patients fare?

  • CMS rates it 5 of 5 stars (Jan 1, 2021 to Dec 31, 2024).
  • Compared by CMS with what it expects for the facility’s patients: patient survival, as expected; hospital admissions, as expected; readmissions to hospital, as expected; emergency department visits, as expected; emergency department visits within 30 days of a hospital stay, as expected; bloodstream infections, as expected; patients dialysing through a fistula, as expected; patients put on a kidney transplant waitlist in their first year of dialysis, as expected; patients on a kidney transplant waitlist, as expected.
  • CMS gives no : “Too few completed survey responses to report.”
Source:

CMS, Dialysis Facility - Listing by Facility and Patient survey (ICH CAHPS) - Facility. Released Jul 15, 2026. Updated quarterly.

Ratings and measures, as published
MeasureRating
Star ratingCMS’s star rating for dialysis facilities, 1 to 55 of 5
Patient survey ratingCMS star rating from its survey of the facility’s in-center hemodialysis patients (ICH CAHPS), 1 to 5Not rated

How does it compare nearby?

  • Of the 7 dialysis facilities CMS lists in Loudoun County, 7 have a star rating from CMS: 2 rated 5 of 5, 2 rated 4 of 5, 2 rated 3 of 5, 1 rated 2 of 5.
  • CMS rates this one 5 of 5.
Source:

CMS, Dialysis Facility - Listing by Facility. Released Jul 15, 2026. Updated quarterly.

What the record doesn’t say

  • CMS doesn’t publish fines or other penalties for dialysis facilities, so none are shown.
  • Only complaints that led to a citation appear; complaints that didn’t aren’t published.
  • QCOR says it has no dialysis inspection reports after February 19, 2026, while it moves to a new system: a later inspection is not shown yet.
  • CMS doesn’t publish staffing levels for dialysis facilities.
  • CMS publishes no owners file for dialysis facilities: the chain it lists is the only owner named.

Sources

If you believe something here is wrong, a correction starts with the agency whose record this copies: CMS. CMS’s own record is on Care Compare. If Hearth Record copied something wrongly, it will fix it and log the correction publicly, with its date: how corrections work.

Source:

This copy of the record was made on Oct 30, 2026.

From the facility

The public record above comes first. Anything the facility adds will appear here, below it, and say who wrote it.

Replies

None. Replies aren’t open yet. When they open, the facility will be able to answer any finding for free, and the reply will show beside that finding, unedited and dated.

Paid listing

None. Paid listings aren’t open yet. When they open, anything paid for will say “Paid by the facility”, and paying will never change a finding, a rating or the order of results.

How to read a record

Four things every record does, shown on an example record made up for this guide.

An example record, made up for this guide

An example nursing home

Made up for this guide: no real place is shown

Not fully inspected in over two years (CMS flag)

11 health citations at the latest inspection cycle

The state average is 14.3.

Source:

CMS, State and US Averages and Health Deficiencies. Released Oct 28, 2026. Updated monthly.

From the homeNone yet. Replies and paid listings aren’t open, and when they open they will sit here, below the record.

1 of 4

Every fact names its source.

Who published it, when, and how often it changes sit beside each fact, with a link to the agency’s own file.

Sign in

A free account keeps your watch list, shortlists, comparisons and saved searches on every device, and can email you when something you watch changes. Browsing never needs one.