2301 Valor Dr, Winchester, Virginia 22601. (540) 667-0227.

CMS’s own record, on Care Compare

Watch and the shortlist are kept with a free account, on every device. Your watch list. CMS’s own record is on Care Compare.

The short answer

Record last released by CMS on Oct 28, 2026.

The last 24 months 6 deficiencies in 1 month of the last 36. Last cited May 2025. Most serious: Standard-level. Every month

Each figure’s source sits beside it, in its section below.

What these words mean3
Star ratings
CMS rates some kinds of place from 1 to 5 stars, more stars meaning better on CMS’s own measures for that kind: for a nursing home, its health inspections, staffing and quality measures. A rating is CMS’s summary of those measures; it doesn’t promise good care. Source: CMS, Care Compare and the Five-Star Quality Rating System.
Inspection (survey)
A visit by state inspectors, often unannounced, who check a place against the rules it must meet. For nursing homes and other places Medicare pays, CMS calls these visits surveys: a standard survey of a nursing home comes at least every 15 months, and a complaint survey whenever a complaint calls for one. Source: CMS; 42 CFR 488.308.
Deficiency, citation, violation
What inspectors write up when a place didn’t meet a rule: the rule, what they saw, and when. CMS calls it a deficiency; states may say citation or violation. It is the inspectors’ finding, not a court’s, and the place is usually asked for a plan to correct it. Source: CMS, statement of deficiencies (Form CMS-2567); each state’s licensing agency.

What did inspectors find?

The last inspection on record was on May 21, 2025: a standard inspection.

6 deficiencies cited in the last three years.

Source:

CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.

When those deficiencies happened

6 deficiencies in 1 month of the last 36. Last cited May 2025. Most serious: Standard-level. The last 3 years, to Oct 30, 2026.

6 deficiencies by month over the last 3 years. Each cell is one month.
JanFebMarAprMayJunJulAugSepOctNovDec
2023 NovDec
2024 JanFebMarAprMayJunJulAugSepOctNovDec
2025 JanFebMarAprMayJunJulAugSepOctNovDec
2026 JanFebMarAprMayJunJulAugSepOct

Hover or focus a month to read it.

No visit on record Visited, nothing cited A stronger orange is more serious, on its source’s own levels, read onto four bands: from the least serious it publishes to the most
Source:

Hearth Record drew this from the dates and levels in the source’s own records.

Each deficiency, as cited

Rule titles as CMS’s inspectors cite them, set in sentence case.

Source:

CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.

May 21, 2025: standard inspection6 deficiencies
  • Ic - Wear Gloves/Hand Hygiene

    The inspectors’ words, 518 words

    “IC-WEAR GLOVES/HAND HYGIENE CFR(s): 494.30(a)(1) Wear disposable gloves when caring for the patient or touching the patient’s equipment at the dialysis station. Staff must remove gloves and wash hands between each patient or station. This Standard is not met as evidenced by: 49355 Based on observations, interviews and document review, it was determined the facility failed to follow infection control and prevention practices related to hand hygiene and glove changing. Specifically, hand hygiene (HH) was not performed and gloves were not changed, per policy, in one (1) out of two (2) observations of discontinuation of dialysis with a central venous catheter (CVC) and in one (1) out of three (3) observations of discontinuation of dialysis with an arteriovenous (AV) fistula. The findings: A review of the facility’s policy entitled, “Infection Control for Dialysis Facilities,” policy: 1-05-01, revision date April 2023, reads, in part: “Hand Hygiene 1. All teammates...will perform hand hygiene ... b. prior to gloving and immediately after removal of gloves, ... d. after patient and dialysis delivery system contact, ... g. before touching clean areas such as supplies, supply car and chairside keyboard/mouse ... PPE ... 7. Disposable gloves will be worn when caring for the patient or touching the patient’s equipment at the dialysis station.... a. Gloves should be changed when: ... ii. When going from a ‘dirty’ area or take to a ‘clean’ area or task.” A review of the facility’s procedure entitled, “Central Venous Catheter (CVC) with Clearguard HD Antimicrobial End Caps Procedure,” procedure: 1-04-02B, revision date April 2025, reads, in part: ... “Upon Completion of Dialysis 26. Perform hand hygiene per procedure. Put on PPE.... Hand hygiene helps prevent cross contamination. PPE is worm to protect teammate. ... 29. Remove gloves and discard, perform hand hygiene per procedure and re-glove. ... 31. Remove gloves and discard, perform hand hygiene per procedure and re-glove.” A review of the facility’s procedure entitled, “Post Dialysis Vascular Access Care: Fistula/Graft Using Safety Fistula Needles,” procedure: 1-04-01B, revision date April 2023, reads, in part: ... “1. Perform hand hygiene. Put on PPE. Hand hygiene protects patient and teammate from cross contamination. PPE is worn to protect teammate.” On May 20, 2025, at 1:22 P.M., while discontinuing dialysis on MR24 at station #11, EMP6 did not remove gloves, perform HH or don clean gloves before disinfecting the CVC connections. On May 20, 2025, at 8:56 A.M., while discontinuing dialysis on MR20 at station #12, EMP10 did not remove gloves, perform HH or don clean gloves before aseptically removing the access needles from an AV fistula. On May 20, 2025, at 9:07 A.M., while discontinuing dialysis on MR22 at station #3, EMP6 placed item’s in the patient’s duffle bag, touching the bag. EMP6 then used the computer, touching the screen, picked trash off the floor and then proceeded to flush the lines and remove the access needles from MR22’s AV fistula. MR22 never removed gloves, performed HH or donned clean gloves during this process. During separate interviews with MR1 and MR2 on May 20, 2025, both employees agreed that glove changes and HH should have occurred in these instances.”

    Rule V0113. Standard-level.

  • Ic - Clean, Disinfect Surfaces & Equipment/Written Protocols

    The inspectors’ words, 295 words

    “IC-DISINFECT SURFACES/EQUIP/WRITTEN PROTOCOL CFR(s): 494.30(a)(4)(ii) [The facility must demonstrate that it follows standard infection control precautions by implementing- (4) And maintaining procedures, in accordance with applicable State and local laws and accepted public health procedures, for the-] (ii) Cleaning and disinfection of contaminated surfaces, medical devices, and equipment. This Standard is not met as evidenced by: 49355 Based on observations, interviews and document review, it was determined the facility failed to ensure that dialysis stations and chairs were appropriately disinfected between patients in three (3) out of four (4) observations. The findings: A review of the facility’s policy entitled, “Infection Control for Dialysis Facilities,” policy: 1-05-01, revision date April 2023, reads, in part: ... “Disinfection ... 13. At the end of each treatment, the dialysis station will be cleaned and disinfected. a. Surfaces to disinfect include but are not necessarily limited to: all surfaces in contact with the patient or their belongings (e.g. dialysis chair...).... ... ii. Priming containers are to be emptied prior to disinfection.” On May 20, 2025, at 9:18 A.M., EMP10 failed to disinfect the inside of the prime waste container at station #11. EMP10 also failed to disinfect the outside of the dialysis chair, underneath each side tray. On May 21, 2025, at 9:58 A.M., EMP6 failed to disinfect the inside of the prime waste container at station #16. EMP6 also failed to disinfect the outside of the dialysis chair, underneath each side tray. On May 21, 2025, at 10:39 A.M., EMP19 failed to disinfect the outside of the dialysis chair, underneath each side tray. During separate interviews with EMP1 and EMP2, both agreed that the outsides of the dialysis chairs, underneath the side trays, should be disinfected and the inside of the prime waste container should be disinfected as well.”

    Rule V0122. Standard-level.

  • Ic - Aseptic Techniques For Iv Meds

    The inspectors’ words, 206 words

    “IC-ASEPTIC TECHNIQUES FOR IV MEDS CFR(s): 494.30(b)(2) [The facility must-] (2) Ensure that clinical staff demonstrate compliance with current aseptic techniques when dispensing and administering intravenous medications from vials and ampules; and This Standard is not met as evidenced by: 49355 Based on observation, interview and document review, it was determined the facility failed to have a mechanism in place to ensure all expired medications are not available for patient use in the dialysis facility. The findings: The facility’s policy entitled, “Medication Policy,” policy 1-06-01, revision date October 2023, reads, in part: ... “Policy: ... 30. All medications in the facility are checked monthly. All medications are checked monthly for expiration dates. ... 32. Disposal of expired medications, including all over the counter and nutritional product samples are removed from the treatment and inventory areas and disposed of per state/local regulations.” On May 19, 2025, at 4:20 P.M., twenty-five (25) single dose vials of Tazicef 1 gram/vial for injection, NDC #00409-5082-16, with an expiration date of February, 2025, were discovered in one of the facility’s medication storage drawers on the treatment floor. EMP9 witnessed and agreed the medication had expired. EMP9 indicated that medications are checked monthly for expiration dates and the Tazicef was obviously overlooked.”

    Rule V0143. Standard-level.

  • Vascular Access - Monitor/Referrals

    The inspectors’ words, 308 words

    “POC-VASCULAR ACCESS-MONITOR/REFERRALS CFR(s): 494.90(a)(5) The interdisciplinary team must provide vascular access monitoring and appropriate, timely referrals to achieve and sustain vascular access. The hemodialysis patient must be evaluated for the appropriate vascular access type, taking into consideration co-morbid conditions, other risk factors, and whether the patient is a potential candidate for arteriovenous fistula placement. This Standard is not met as evidenced by: 49355 Based on observations, interviews and document review, it was determined the facility failed to properly care for arteriovenous (AV) grafts/fistulas according to the facility’s policy. Specifically, in three (3) out of three (3) observations, facility staff touched the cannulation sites of arteriovenous (AV) fistulas after the areas were prepped with antiseptic. The findings include: The facility’s procedure entitled, “AV Fistula or Graft Cannulation with JMS Sysloc (R) Mini Safety Fistula Needles (SFN) and Administration of Heparin Loading Dose,” procedure 1-04-01D, revision date April 2025, reads, in part: ... “Procedure: ... 13. Do not palpate insertion site once area has been prepped. Once the access site has been prepped, touching it will contaminate the site and possible allow for the introduction of bacteria during contamination.” On May 21, 2025, at 10:15 A.M., EMP6 palpated MR25’s AV fistula cannulation site at station #14 after cleansing the area with antiseptic and did not recleanse the area before accessing the site. On May 21, 2025, at 10:24 A.M., EMP8 palpated MR26’s AV fistula cannulation site at station #12 after cleansing the area with antiseptic and did not recleanse the area before accessing the site. On May 21, 2025, at 10:31 A.M., EMP18 palpated MR27’s AV fistula cannulation site at station #5 after cleansing the area with antiseptic and did not recleanse the area before accessing the site. EMP1 and EMP2 indicated during separate interviews that the site should be recleansed after palpating and before cannulating and not touched again.”

    Rule V0550. Standard-level.

  • Continuously Monitor/Take Action/Track/Sustain Improve

    The inspectors’ words, 198 words

    “QAPI-MONITOR/ACT/TRACK/SUSTAIN IMPROVE CFR(s): 494.110(b) The dialysis facility must continuously monitor its performance, take actions that result in performance improvements, and track performance to ensure that improvements are sustained over time. This Standard is not met as evidenced by: 40084 Based on interview and document review, it was determined the facility’s Quality Assurance and Performance Improvement (QAPI) program failed to take action to ensure sustained improvement over time. Specifically, the QAPI program failed to correct known issues related to the use of vascular clamps. The findings include: The Current survey: Based on observations, interviews and document review, it was determined that the facility failed to follow policy related to the use of clamps in two (2) in-center hemodialysis patients and failed to have an order for the usage of clamps in one (1) in-center hemodialysis patient. The Prior Recertification Survey Ending November 3, 2021 Based on observations, interview, and facility document review, it was determined that the facility’s staff 1.) failed to follow facility policy when using vascular access clamps for two (2) of two (2) patients and 2.) failed to ensure a physician’s order was present to use vascular access clamps for one (1) of two (2) patients.”

    Rule V0638. Standard-level.

  • Md Resp - Ensure All Adhere To P&P

    The inspectors’ words, 316 words

    “MD RESP-ENSURE ALL ADHERE TO P&P CFR(s): 494.150(c)(2)(i) The medical director must- (2) Ensure that- (i) All policies and procedures relative to patient admissions, patient care, infection control, and safety are adhered to by all individuals who treat patients in the facility, including attending physicians and nonphysician providers; This Standard is not met as evidenced by: 49355 Based on observations, interviews and document review, it was determined that the facility failed to follow policy related to the use of clamps in two (2) in-center hemodialysis patients and failed to have an order for the usage of clamps in one (1) in-center hemodialysis patient. The Findings: The facility’s policy entitled, “Utilizing Vascular Access Clamps,” policy 1-04-08, revision date April 2019, reads, in part: ... “Policy: ... 3. Vascular access clamps should not be used routinely. However, if a patient is unable to hold his/her own sites, it is recommended that only one (!) clamp is used at a time and should not be left on longer than 20 minutes.” On May 19, 2025, at 3:36 P.M., MR16 was observed at station #15 with two (2) vascular clamps placed by EMP20. A review of the medical record for MR16 revealed there were no orders for clamp usage in the record. On May 20, 2025, at 9:28 A.M., MR28 was observed at station #6 with two (2) vascular clamps placed by EMP17. A review of the medical record for MR28 revealed there was an order for the usage of clamps in the record, but the order was for two (2) clamps, which is contradictory to facility policy. During an interview on May 21, 2025, at 10:20 A.M., EMP16 agreed the facility policy stated only one (1) clamp should be used at a time. During an interview on May 21, 2025, at 10:48 A.M., EMP1 agreed the facility policy stated only one (1) clamp should be used at a time.”

    Rule V0715. Standard-level.

The one inspection in the last three years
Inspections on record
DateVisitWhat the record says
May 21, 2025Standard inspection6 deficiencies cited

Is it certified?

  • Medicare-certified dialysis facility, certified or last recertified on Jul 1, 1980.
  • Run for profit.
  • No deficiency on record in the last three years.
  • Chain: DaVita.
Source:

CMS, Dialysis Facility - Listing by Facility. Released Jul 15, 2026. Updated quarterly.

CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.

Has it been penalized?

  • CMS doesn’t publish fines or other penalties for dialysis facilities.
  • None of the deficiencies cited in the last three years came from an inspection that included a complaint investigation.
Source:

CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.

What does it offer?

  • Offers in-center hemodialysis, peritoneal dialysis, home hemodialysis training and a shift starting at 5 p.m. or later.
  • 25 dialysis stations.
  • CMS doesn’t publish staffing levels for dialysis facilities.
  • In CMS’s survey, patients rate its staff 4 of 5.
Source:

CMS, Dialysis Facility - Listing by Facility and Patient survey (ICH CAHPS) - Facility. Released Jul 15, 2026. Updated quarterly.

Who owns it?

  • Part of the DaVita chain, as CMS lists it.
  • CMS publishes no owners file for dialysis facilities, so no other owner is named.
Source:

CMS, Dialysis Facility - Listing by Facility. Released Jul 15, 2026. Updated quarterly.

How do patients fare?

  • CMS rates it 3 of 5 stars (Jan 1, 2021 to Dec 31, 2024).
  • Compared by CMS with what it expects for the facility’s patients: patient survival, as expected; hospital admissions, as expected; readmissions to hospital, as expected; blood transfusions, worse than expected; emergency department visits, as expected; emergency department visits within 30 days of a hospital stay, as expected; bloodstream infections, as expected; patients dialysing through a fistula, as expected; patients put on a kidney transplant waitlist in their first year of dialysis, as expected; patients on a kidney transplant waitlist, as expected.
  • Patients rate it 3 of 5 in CMS’s survey of in-center hemodialysis patients (51 interviews, Oct 18, 2024 to Jul 11, 2025): 79% rated the facility 9 or 10 out of 10.
Source:

CMS, Dialysis Facility - Listing by Facility and Patient survey (ICH CAHPS) - Facility. Released Jul 15, 2026. Updated quarterly.

Ratings and measures, as published
MeasureRating
Star ratingCMS’s star rating for dialysis facilities, 1 to 53 of 5
Patient survey ratingCMS star rating from its survey of the facility’s in-center hemodialysis patients (ICH CAHPS), 1 to 53 of 5

How does it compare nearby?

  • Of the 2 dialysis facilities CMS lists in Winchester City, 2 have a star rating from CMS: 2 rated 3 of 5.
  • CMS rates this one 3 of 5.
Source:

CMS, Dialysis Facility - Listing by Facility. Released Jul 15, 2026. Updated quarterly.

1 compared
PlaceStar rating
Fmc Shenandoah Valley3

What the record doesn’t say

  • CMS doesn’t publish fines or other penalties for dialysis facilities, so none are shown.
  • Only complaints that led to a citation appear; complaints that didn’t aren’t published.
  • QCOR says it has no dialysis inspection reports after February 19, 2026, while it moves to a new system: a later inspection is not shown yet.
  • CMS doesn’t publish staffing levels for dialysis facilities.
  • CMS publishes no owners file for dialysis facilities: the chain it lists is the only owner named.

Sources

If you believe something here is wrong, a correction starts with the agency whose record this copies: CMS. CMS’s own record is on Care Compare. If Hearth Record copied something wrongly, it will fix it and log the correction publicly, with its date: how corrections work.

Source:

This copy of the record was made on Oct 30, 2026.

From the facility

The public record above comes first. Anything the facility adds will appear here, below it, and say who wrote it.

Replies

None. Replies aren’t open yet. When they open, the facility will be able to answer any finding for free, and the reply will show beside that finding, unedited and dated.

Paid listing

None. Paid listings aren’t open yet. When they open, anything paid for will say “Paid by the facility”, and paying will never change a finding, a rating or the order of results.

How to read a record

Four things every record does, shown on an example record made up for this guide.

An example record, made up for this guide

An example nursing home

Made up for this guide: no real place is shown

Not fully inspected in over two years (CMS flag)

11 health citations at the latest inspection cycle

The state average is 14.3.

Source:

CMS, State and US Averages and Health Deficiencies. Released Oct 8, 2026. Updated monthly.