Hearth Record

Davita Renal Center of Flower Mound

A dialysis facility in Flower Mound, Texas 75028

4941 Long Prairie Rd, Flower Mound, Texas 75028. (972) 537-5572.

CMS’s own record, on Care Compare

Watch and the shortlist are kept with a free account, on every device. Your watch list. CMS’s own record is on Care Compare.

The short answer

Record last released by CMS on Oct 28, 2026.

The last 24 months 2 deficiencies in 1 month of the last 36. Last cited Mar 2024. Most serious: Standard-level. Every month

Each figure’s source sits beside it, in its section below.

What these words mean3
Star ratings
CMS rates some kinds of place from 1 to 5 stars, more stars meaning better on CMS’s own measures for that kind: for a nursing home, its health inspections, staffing and quality measures. A rating is CMS’s summary of those measures; it doesn’t promise good care. Source: CMS, Care Compare and the Five-Star Quality Rating System.
Inspection (survey)
A visit by state inspectors, often unannounced, who check a place against the rules it must meet. For nursing homes and other places Medicare pays, CMS calls these visits surveys: a standard survey of a nursing home comes at least every 15 months, and a complaint survey whenever a complaint calls for one. Source: CMS; 42 CFR 488.308.
Deficiency, citation, violation
What inspectors write up when a place didn’t meet a rule: the rule, what they saw, and when. CMS calls it a deficiency; states may say citation or violation. It is the inspectors’ finding, not a court’s, and the place is usually asked for a plan to correct it. Source: CMS, statement of deficiencies (Form CMS-2567); each state’s licensing agency.

What did inspectors find?

The last inspection on record was on Mar 20, 2024: a complaint inspection.

2 deficiencies cited in the last three years.

Source:

CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.

When those deficiencies happened

2 deficiencies in 1 month of the last 36. Last cited Mar 2024. Most serious: Standard-level. The last 3 years, to Oct 30, 2026.

2 deficiencies by month over the last 3 years. Each cell is one month.
JanFebMarAprMayJunJulAugSepOctNovDec
2023 NovDec
2024 JanFebMarAprMayJunJulAugSepOctNovDec
2025 JanFebMarAprMayJunJulAugSepOctNovDec
2026 JanFebMarAprMayJunJulAugSepOct

Hover or focus a month to read it.

No visit on record Visited, nothing cited A stronger orange is more serious, on its source’s own levels, read onto four bands: from the least serious it publishes to the most
Source:

Hearth Record drew this from the dates and levels in the source’s own records.

Each deficiency, as cited

Rule titles as CMS’s inspectors cite them, set in sentence case.

Source:

CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.

Mar 20, 2024: complaint inspection2 deficiencies
  • Assess B/P & Fluid Management Needs

    The inspectors’ words, 781 words

    “PA-ASSESS B/P, FLUID MANAGEMENT NEEDS CFR(s): 494.80(a)(2) The patient’s comprehensive assessment must include, but is not limited to, the following: Blood pressure, and fluid management needs. This Standard is not met as evidenced by: 50181 Based on medical record review, policy review and staff interview the facility failed to ensure the direct patient care (DPC) staff reported patient status changes during treatment to the Registered Nurse (RN) to ensure a reassessment was performed and documented with appropriate interventions and/or physician notification, if required. The assessment should include evaluation of the patient’s pre/intra/post and interdialytic blood pressures, interdialytic weight gains, target weight, and related intradialytic symptoms. Findings included: A review of facility policy titled, “CWOW-Pre-intra-Post Treatment Data Collection, Monitoring and Nursing Assessment,” with a revision date of April 2021 includes the following guidance: “ ...PURPOSE: To obtain and document baseline and ongoing information about the patient before, during, and after the dialysis treatment through data collection and nursing assessment. This information will be used in planning and documenting the patient’s dialysis treatment, monitoring during treatment, and for reviewing the patient’s response to the treatment and status prior to discharge. 4. Any abnormal findings or findings outside of any patient specific physician ordered parameters discovered during pre-treatment data collection will be documented and immediately reported to the licensed nurse. If any abnormal finding is reported to the licensed nurse pre-treatment, the nurse will assess the patient prior to initiation of dialysis. INTRADIALYTIC DATA COLLECTION/ASSESSMENT 11. Abnormal findings or findings outside of any patient-specific physician-ordered parameters will be reported to the licensed nurse immediately (refer to the ‘abnormal findings’ section of this policy). The licensed nurse will use his/her clinical judgment based on individual patient needs to determine if any clinical interventions are necessary. 12. The licensed nurse notifies the physician (or NPP if applicable) as needed of changes in patient status. 13. All findings, interventions, and patient responses will be documented in the patient’s medical record...” Patient #3 treatment record dated 03/18/2024 indicates the following: 06:00: Blood Pressure (BP): 89/55 and HR: 47bpm 06:00 Events and Comments; Treatment started without complications. There is no documentation acknowledging this BP and HR were reportable findings and were reported to the RN by the DPC staff. Patient’s estimated dry weight (EDW) for treatment record 03/18/2024 is 52 kg per the physician’s order. The treatment record indicates the patient’s pre-weight is 57.2kg which calculates at 5.2kg over the EDW and calculates to a 10.2% interdialytic weight gain requiring a pre-assessment from the RN per the facility’s reporting protocol. The pre-assessment was completed by the RN at 06:21 after the treatment initiation time of 06:01. There was no documentation in the RN assessment that the weight gain was identified and reported to the physician for this treatment. The patient’s fluid removal goal was set to 3500mL which exceeds the ordered maximum Ultrafiltration (UF) rate of 13.0mL/kg/hour by the physician. 08:30: HR: 57 08:30 Events and Comments: Patient face; vascular access; and blood line connections visible There is no documentation acknowledging this heart rate was a reportable finding and was reported to the RN by the DPC staff. Patient #4 treatment records dated 03/18/2024 indicates the following: Patient’s EDW: 91kg per physician’s order The treatment record indicates the patient’s pre-weight is 96.9kg which calculates to 5.9kg over the EDW calculating a removal goal of 6400mL to achieve the patient’s EDW. The machine goal was set to remove 4000mL. There is no RN documentation in the pre-assessment acknowledging the adjustment to the patient’s goal for the treatment. Patient left 2.7kg above the EDW for the treatment. Patient #7 treatment records dated 03/18/2024 indicates the following: Patient’s EDW: 77.5kg per physician’s order The treatment record indicates the patient’s pre-weight is 84.7kg which calculates to 7.2kg over the EDW and calculates to a 5.5% intradialytic weight gain requiring a pre-assessment from the RN per the facility’s reporting protocol. The pre-assessment was completed by the RN at 05:49 after the treatment initiation time of 05:46. There was no documentation in the RN assessment that the weight gain was identified and reported to the physician for this treatment. The patient’s fluid removal goal was set to 2000mL with no documentation of a physician order for this goal. Patient #5 treatment record dated 03/18/2024 indicates the patient’s heart rate (HR) was 52bpm at 05:17 and 52bpm at 08:00. There is no documentation acknowledging this heart rate was a reportable finding and was reported to the RN by the DPC staff. On 03/20/2024, an interview with the FA confirmed the facility’s reportable parameters and documentation required for out of parameter findings pre/intra/post dialysis treatment by the DPC staff and licensed nurse providing care to the patient.”

    Rule V0504. Standard-level. From a complaint.

  • Achieve Adequate Clearance

    The inspectors’ words, 276 words

    “POC-ACHIEVE ADEQUATE CLEARANCE CFR(s): 494.90(a)(1) Achieve and sustain the prescribed dose of dialysis to meet a hemodialysis Kt/V of at least 1.2 and a peritoneal dialysis weekly Kt/V of at least 1.7 or meet an alternative equivalent professionally-accepted clinical practice standard for adequacy of dialysis. This Standard is not met as evidenced by: 50181 Based on record review, the facility failed to follow the patient’s ordered plan of care by not following the ordered blood flow rate (BFR) and/or dialysate flow rate (DFR) for one or more treatment records reviewed. The patients’ dialysis prescriptions (dialyzer, blood flow rate, dialysate flow rate, length of treatment time) and the efficacy of the vascular access affect the dose of dialysis delivered. Review of Patient #3 treatment record for 03/18/2024 revealed the BFR was ordered to run at 350mL/min. Review of the intradialytic records revealed the BFR ran at 270 mL/min from 08:30-09:00, then the BFR ran at 300mL/min from 09:00-10:00 with no documentation reporting the change to the charge nurse (staff #5) by the patient care technician (staff #6) and no supporting documentation from the nurse related to the variation in hemodialysis orders for the treatment. Review of Patient #4 treatment record for 03/18/2024 revealed the DFR was ordered to run at 800mL/min. Review of the intradialytic records revealed the DFR ran at 500mL/min from 05:21-05:29, then the DFR ran at 800ml/min from 05:59 until treatment was terminated at 08:29. There is no evidence of documentation reporting the change to the charge nurse (staff #5) by the patient care technician (staff #7) and no supporting documentation from the nurse related to the variation in hemodialysis orders for the treatment.”

    Rule V0544. Standard-level. From a complaint.

The one inspection in the last three years
Inspections on record
DateVisitWhat the record says
Mar 20, 2024Complaint inspection2 deficiencies cited

Is it certified?

  • Medicare-certified dialysis facility, certified or last recertified on May 2, 2017.
  • Run for profit.
  • No deficiency on record in the last three years.
  • Chain: DaVita.
Source:

CMS, Dialysis Facility - Listing by Facility. Released Jul 15, 2026. Updated quarterly.

CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.

Has it been penalized?

  • CMS doesn’t publish fines or other penalties for dialysis facilities.
  • 2 deficiencies cited in the last three years came from inspections that included a complaint investigation.
Source:

CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.

What does it offer?

  • Offers in-center hemodialysis and peritoneal dialysis.
  • Doesn’t offer home hemodialysis training and a shift starting at 5 p.m. or later.
  • 13 dialysis stations.
  • CMS doesn’t publish staffing levels for dialysis facilities.
Source:

CMS, Dialysis Facility - Listing by Facility and Patient survey (ICH CAHPS) - Facility. Released Jul 15, 2026. Updated quarterly.

Who owns it?

  • Part of the DaVita chain, as CMS lists it.
  • CMS publishes no owners file for dialysis facilities, so no other owner is named.
Source:

CMS, Dialysis Facility - Listing by Facility. Released Jul 15, 2026. Updated quarterly.

How do patients fare?

  • CMS rates it 4 of 5 stars (Jan 1, 2021 to Dec 31, 2024).
  • Compared by CMS with what it expects for the facility’s patients: patient survival, as expected; hospital admissions, as expected; readmissions to hospital, as expected; emergency department visits, as expected; emergency department visits within 30 days of a hospital stay, as expected; bloodstream infections, as expected; patients dialysing through a fistula, as expected; patients put on a kidney transplant waitlist in their first year of dialysis, as expected; patients on a kidney transplant waitlist, as expected.
  • CMS gives no : “Too few completed survey responses to report.”
Source:

CMS, Dialysis Facility - Listing by Facility and Patient survey (ICH CAHPS) - Facility. Released Jul 15, 2026. Updated quarterly.

Ratings and measures, as published
MeasureRating
Star ratingCMS’s star rating for dialysis facilities, 1 to 54 of 5
Patient survey ratingCMS star rating from its survey of the facility’s in-center hemodialysis patients (ICH CAHPS), 1 to 5Not rated

How does it compare nearby?

  • Of the 10 dialysis facilities CMS lists in Denton County, 10 have a star rating from CMS: 4 rated 4 of 5, 2 rated 3 of 5, 4 rated 2 of 5.
  • CMS rates this one 4 of 5.
Source:

CMS, Dialysis Facility - Listing by Facility. Released Jul 15, 2026. Updated quarterly.

What the record doesn’t say

  • CMS doesn’t publish fines or other penalties for dialysis facilities, so none are shown.
  • Only complaints that led to a citation appear; complaints that didn’t aren’t published.
  • QCOR says it has no dialysis inspection reports after February 19, 2026, while it moves to a new system: a later inspection is not shown yet.
  • CMS doesn’t publish staffing levels for dialysis facilities.
  • CMS publishes no owners file for dialysis facilities: the chain it lists is the only owner named.

Sources

If you believe something here is wrong, a correction starts with the agency whose record this copies: CMS. CMS’s own record is on Care Compare. If Hearth Record copied something wrongly, it will fix it and log the correction publicly, with its date: how corrections work.

Source:

This copy of the record was made on Oct 30, 2026.

From the facility

The public record above comes first. Anything the facility adds will appear here, below it, and say who wrote it.

Replies

None. Replies aren’t open yet. When they open, the facility will be able to answer any finding for free, and the reply will show beside that finding, unedited and dated.

Paid listing

None. Paid listings aren’t open yet. When they open, anything paid for will say “Paid by the facility”, and paying will never change a finding, a rating or the order of results.

How to read a record

Four things every record does, shown on an example record made up for this guide.

An example record, made up for this guide

An example nursing home

Made up for this guide: no real place is shown

Not fully inspected in over two years (CMS flag)

11 health citations at the latest inspection cycle

The state average is 14.3.

Source:

CMS, State and US Averages and Health Deficiencies. Released Oct 28, 2026. Updated monthly.

From the homeNone yet. Replies and paid listings aren’t open, and when they open they will sit here, below the record.

1 of 4

Every fact names its source.

Who published it, when, and how often it changes sit beside each fact, with a link to the agency’s own file.

Sign in

A free account keeps your watch list, shortlists, comparisons and saved searches on every device, and can email you when something you watch changes. Browsing never needs one.