Davita Keller Dialysis
A dialysis facility in Fort Worth, Texas 76244
11000 N Riverside Drive, Fort Worth, Texas 76244. (817) 337-5483.
Watch and the shortlist are kept with a free account, on every device. Your watch list. CMS’s own record is on Care Compare.
The short answer
Record last released by CMS on Oct 28, 2026.
- 1of 5 CMS’s star rating
- Not rated patient survey rating
- 1 deficiency cited in the last three years
- 17 dialysis stations
Each figure’s source sits beside it, in its section below.
What these words mean3
- Star ratings
- CMS rates some kinds of place from 1 to 5 stars, more stars meaning better on CMS’s own measures for that kind: for a nursing home, its health inspections, staffing and quality measures. A rating is CMS’s summary of those measures; it doesn’t promise good care. Source: CMS, Care Compare and the Five-Star Quality Rating System.
- Inspection (survey)
- A visit by state inspectors, often unannounced, who check a place against the rules it must meet. For nursing homes and other places Medicare pays, CMS calls these visits surveys: a standard survey of a nursing home comes at least every 15 months, and a complaint survey whenever a complaint calls for one. Source: CMS; 42 CFR 488.308.
- Deficiency, citation, violation
- What inspectors write up when a place didn’t meet a rule: the rule, what they saw, and when. CMS calls it a deficiency; states may say citation or violation. It is the inspectors’ finding, not a court’s, and the place is usually asked for a plan to correct it. Source: CMS, statement of deficiencies (Form CMS-2567); each state’s licensing agency.
What did inspectors find?
The last inspection on record was on Jan 14, 2026: a complaint inspection.
1 deficiency cited in the last three years.
CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.
When those deficiencies happened
1 deficiency in 1 month of the last 36. Last cited Jan 2026. Most serious: Standard-level. The last 3 years, to Oct 30, 2026.
| Jan | Feb | Mar | Apr | May | Jun | Jul | Aug | Sep | Oct | Nov | Dec | |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 2023 | Nov | Dec | ||||||||||
| 2024 | Jan | Feb | Mar | Apr | May | Jun | Jul | Aug | Sep | Oct | Nov | Dec |
| 2025 | Jan | Feb | Mar | Apr | May | Jun | Jul | Aug | Sep | Oct | Nov | Dec |
| 2026 | Jan | Feb | Mar | Apr | May | Jun | Jul | Aug | Sep | Oct |
Hover or focus a month to read it.
Hearth Record drew this from the dates and levels in the source’s own records.
Each deficiency, as cited
Rule titles as CMS’s inspectors cite them, set in sentence case.
CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.
Jan 14, 2026: standard inspection1 deficiency
-
Assess B/P & Fluid Management Needs
The inspectors’ words, 880 words
“PA-ASSESS B/P, FLUID MANAGEMENT NEEDS CFR(s): 494.80(a)(2) The patient’s comprehensive assessment must include, but is not limited to, the following: Blood pressure, and fluid management needs. This Standard is not met as evidenced by: 30377 Based on record review and staff interview, the facility staff failed to ensure patient vital signs that fell outside of the facility’s set parameters were reported to the Registered Nurse and/or physician for further assessment and intervention on 3 (Patient # 1, #2 and # 3) of 8 patient medical records reviewed. The facility staff failed to follow the “Pre-Intra-Post Treatment Data Collection, Monitoring, and Nursing Assessment” policy. Findings include: Review of hemodialysis flow sheets on 01/13/2026 in the facility conference room revealed the following discrepancies: Patient #1 Flow Sheet dated 01/07/2026 Dialysis Prescription Treatment Time: 4.0 hours Pre Treatment Vitals: Time: 05:07 AM Blood Pressure: 192/97 Heart Rate: 73 Post Treatment Vitals: Time: 09:12 AM Blood Pressure: 156/85 Heart Rate: 72 There was no documentation provided at time of review that the registered nurse was notified that the initial blood pressure was 192/97. Treatment Initiated Time: 05:07 AM Blood Pressure: 177/96 Heartrate 75. There was no documentation provided that a registered nurse completed a nursing round that included a prescription verification within the first hour of treatment. 07:31 AM Blood Pressure: 196/97 Heart Rate 73 with direct patient care technician documenting “ .....blood pressure elevated.” There was no documentation provided at time of review that the registered nurse was notified that the patient was hypertensive. 08:00 AM Blood Pressure: 193/99 Heart Rate 78 with direct patient care technician documenting “ ....at this time blood pressure remains elevated: LVN aware.” There was no documentation provided at time of review that the registered nurse was notified that the patient was hypertensive. 11: 36 AM Post Treatment Assessment: The registered nurse documented “Patient leaving stable, no complaints. asymptomatic hypertension present ...” There was no documentation provided at time of review that the registered nurse addressed the hypertension during the dialysis treatment. Patient #2 Flow Sheet dated 12/29/2025 Dialysis Prescription Treatment Time: 4.15 hours Pre Treatment Vitals: Time: 05:04 AM Blood Pressure: 219/103 Heart Rate: 82 Post Treatment Vitals: Time: 09:39 AM Blood Pressure: 151/90 Heart Rate: 83 Treatment Initiated Time: 05:15 AM Blood Pressure: 217/103 Heartrate 81. 05:15 AM Blood Pressure: 217/103 Heart Rate 81 with the direct patient care technician documenting “ .....Registered nurse aware of elevated blood pressure.” There was no documentation provided at time of review that the registered nurse addressed the initial blood pressure prior to the patient being placed on the dialysis machine. 05:32 AM Blood Pressure: 200/103 Heart Rate 76 with the direct patient care technician documenting “ Patient monitored: eyes closed: patient resting.” 05:57 AM the registered nurse documented “Prescription verified ....patient placed on profile 2 due to elevated blood pressure: Patient asymptomatic: Blood pressure within treatment parameters.” 06:23 AM Pre-Treatment assessment completed with the registered nurse documenting “Blood Pressure elevated: Patient asymptomatic” Patient #3 Flow Sheet dated 01/09/2026 Dialysis Prescription Treatment Time: 4.0 hours Pre Treatment Vitals: Time: 05:40 AM Blood Pressure: 101/65 Heart Rate: 73 Post Treatment Vitals: Time: 10:01 AM Blood Pressure: 118/66 Heart Rate: 78 Treatment Initiated Time: 06:02 AM Blood Pressure: 91/57 Heartrate 72. 09:01 AM Blood Pressure: 83/53 Heart Rate 75 with direct patient care technician documenting “ Patient awake alert and states no complaint at this time recheck blood pressure.” There was no documentation provided at time of review that the registered nurse was notified of the hypotensive episode during treatment. 09:04 AM Blood Pressure: 67/43 Heart Rate 73 with direct patient care technician documenting “readjusted cuff: Ultra filtration off due to low blood pressure.” There was no documentation provided at time of review that the registered nurse was notified that the patient was hypotensive and that the Ultrafiltration on the dialysis machine was turned off. 09:06 AM Blood Pressure: 87/56 Heart Rate 74 with direct patient care technician documenting “ Patient awake alert and states no complaints at this time blood pressure remains low.” There was no documentation provided at time of review that the registered nurse was notified that the patient was hypotensive. 09:15 AM Blood Pressure: 97/59 Heart Rate 73 with direct patient care technician documenting “ Blood pressure improving: Ultra Filtration remains off.” There was no documentation provided at time of review that the registered nurse was notified that the patient remained hypotensive and that the Ultrafiltration had been stopped on the dialysis machine. A review of the facility policy, “ Data Collection and Patient Assessment Reporting Guidelines.” Revealed that the following parameters were provided for the direct patient care staff to give guidance when a registered nurse needed to evaluate the patient status. Pre Dialysis: Blood Pressure: Systolic: < 90 or > 180 Diastolic: < 45 or > 110 Pulse: < 60 or > 110 Temperature: > 100.5 F Any Complaints made by the patient Intra Dialysis: Blood Pressure: >20 mmHg decrease from prior blood pressure check at anytime during treatment. Increase to > 180/110 An interview conducted with Staff Member #2 and Staff Member #3 on 01/13/26 following their own review of the findings revealed they were unaware of the discrepancies found in the flow sheets. Staff Member #2 and Staff Member #3 confirmed the above findings.”
All 2 inspections in the last three years
| Date | Visit | What the record says |
|---|---|---|
| Jan 14, 2026 | Complaint inspection | No deficiencies cited |
| Jan 14, 2026 | Standard inspection | 1 deficiency cited |
Is it certified?
- Medicare-certified dialysis facility, certified or last recertified on Sep 1, 2016.
- Run for profit.
- No For hospices, home health agencies, hospitals and dialysis facilities, CMS writes deficiencies at two levels. Standard is the usual one; condition-level is the more serious, when a problem is serious enough that the provider doesn’t meet a whole condition of taking part in Medicare. Source: CMS, State Operations Manual. deficiency on record in the last three years.
- Chain: DaVita.
CMS, Dialysis Facility - Listing by Facility. Released Jul 15, 2026. Updated quarterly.
CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.
Has it been penalized?
- CMS doesn’t publish fines or other penalties for dialysis facilities.
- None of the deficiencies cited in the last three years came from an inspection that included a complaint investigation.
CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.
What does it offer?
- Offers in-center hemodialysis and peritoneal dialysis.
- Doesn’t offer home hemodialysis training and a shift starting at 5 p.m. or later.
- 17 dialysis stations.
- CMS doesn’t publish staffing levels for dialysis facilities.
CMS, Dialysis Facility - Listing by Facility and Patient survey (ICH CAHPS) - Facility. Released Jul 15, 2026. Updated quarterly.
Who owns it?
- Part of the DaVita chain, as CMS lists it.
- CMS publishes no owners file for dialysis facilities, so no other owner is named.
CMS, Dialysis Facility - Listing by Facility. Released Jul 15, 2026. Updated quarterly.
How do patients fare?
- CMS rates it 1 of 5 stars (Jan 1, 2021 to Dec 31, 2024).
- Compared by CMS with what it expects for the facility’s patients: patient survival, as expected; hospital admissions, as expected; readmissions to hospital, as expected; blood transfusions, as expected; emergency department visits, as expected; emergency department visits within 30 days of a hospital stay, as expected; bloodstream infections, as expected; patients dialysing through a fistula, as expected; patients on a kidney transplant waitlist, as expected.
- CMS gives no CMS rates some kinds of place from 1 to 5 stars, more stars meaning better on CMS’s own measures for that kind: for a nursing home, its health inspections, staffing and quality measures. A rating is CMS’s summary of those measures; it doesn’t promise good care. Source: CMS, Care Compare and the Five-Star Quality Rating System.: “Too few completed survey responses to report.”
CMS, Dialysis Facility - Listing by Facility and Patient survey (ICH CAHPS) - Facility. Released Jul 15, 2026. Updated quarterly.
| Measure | Rating |
|---|---|
| Star ratingCMS’s star rating for dialysis facilities, 1 to 5 | 1 of 5 |
| Patient survey ratingCMS star rating from its survey of the facility’s in-center hemodialysis patients (ICH CAHPS), 1 to 5 | Not rated |
How does it compare nearby?
- Of the 53 dialysis facilities CMS lists in Tarrant County, 48 have a star rating from CMS: 1 rated 5 of 5, 1 rated 4 of 5, 14 rated 3 of 5, 22 rated 2 of 5, 10 rated 1 of 5.
- CMS rates this one 1 of 5.
CMS, Dialysis Facility - Listing by Facility. Released Jul 15, 2026. Updated quarterly.
What the record doesn’t say
- CMS doesn’t publish fines or other penalties for dialysis facilities, so none are shown.
- Only complaints that led to a citation appear; complaints that didn’t aren’t published.
- QCOR says it has no dialysis inspection reports after February 19, 2026, while it moves to a new system: a later inspection is not shown yet.
- CMS doesn’t publish staffing levels for dialysis facilities.
- CMS publishes no owners file for dialysis facilities: the chain it lists is the only owner named.
Sources
-
Centers for Medicare & Medicaid Services, Dialysis Facility - Listing by Facility (23ew-n7w9).
Released Jul 15, 2026 and checked Oct 30, 2026. Updated quarterly. Public domain (U.S. Government work).
-
Centers for Medicare & Medicaid Services, Patient survey (ICH CAHPS) - Facility (59mq-zhts).
Released Jul 15, 2026 and checked Oct 30, 2026. Updated quarterly. Public domain (U.S. Government work).
-
Centers for Medicare & Medicaid Services, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies (ESRD_2567s_2018_to_2026YTD.xlsx).
Released Oct 28, 2026 and checked Oct 30, 2026. Updated monthly. Public domain (U.S. Government work).
If you believe something here is wrong, a correction starts with the agency whose record this copies: CMS. CMS’s own record is on Care Compare. If Hearth Record copied something wrongly, it will fix it and log the correction publicly, with its date: how corrections work.
This copy of the record was made on Oct 30, 2026.
From the facility
The public record above comes first. Anything the facility adds will appear here, below it, and say who wrote it.
Replies
None. Replies aren’t open yet. When they open, the facility will be able to answer any finding for free, and the reply will show beside that finding, unedited and dated.
Paid listing
None. Paid listings aren’t open yet. When they open, anything paid for will say “Paid by the facility”, and paying will never change a finding, a rating or the order of results.