Davita Dialysis Care of Weatherford

A dialysis facility in Weatherford, Texas 76086

2107 Fort Worth Highway, Weatherford, Texas 76086. (817) 599-6954.

CMS’s own record, on Care Compare

Watch and the shortlist are kept with a free account, on every device. Your watch list. CMS’s own record is on Care Compare.

The short answer

Record last released by CMS on Oct 28, 2026.

The last 24 months 9 deficiencies in 2 months of the last 36. Last cited Feb 2026. Most serious: Condition-level. Every month

Each figure’s source sits beside it, in its section below.

What these words mean4
Star ratings
CMS rates some kinds of place from 1 to 5 stars, more stars meaning better on CMS’s own measures for that kind: for a nursing home, its health inspections, staffing and quality measures. A rating is CMS’s summary of those measures; it doesn’t promise good care. Source: CMS, Care Compare and the Five-Star Quality Rating System.
Inspection (survey)
A visit by state inspectors, often unannounced, who check a place against the rules it must meet. For nursing homes and other places Medicare pays, CMS calls these visits surveys: a standard survey of a nursing home comes at least every 15 months, and a complaint survey whenever a complaint calls for one. Source: CMS; 42 CFR 488.308.
Deficiency, citation, violation
What inspectors write up when a place didn’t meet a rule: the rule, what they saw, and when. CMS calls it a deficiency; states may say citation or violation. It is the inspectors’ finding, not a court’s, and the place is usually asked for a plan to correct it. Source: CMS, statement of deficiencies (Form CMS-2567); each state’s licensing agency.
Condition-level deficiency
For hospices, home health agencies, hospitals and dialysis facilities, CMS writes deficiencies at two levels. Standard is the usual one; condition-level is the more serious, when a problem is serious enough that the provider doesn’t meet a whole condition of taking part in Medicare. Source: CMS, State Operations Manual.

What did inspectors find?

The last inspection on record was on Feb 4, 2026: a standard inspection.

9 deficiencies cited in the last three years, 2 of them at condition level, the most serious.

2 deficiencies at condition level, the more serious of CMS’s two levels

Source:

CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.

When those deficiencies happened

9 deficiencies in 2 months of the last 36. Last cited Feb 2026. Most serious: Condition-level. The last 3 years, to Oct 30, 2026.

9 deficiencies by month over the last 3 years. Each cell is one month.
JanFebMarAprMayJunJulAugSepOctNovDec
2023 NovDec
2024 JanFebMarAprMayJunJulAugSepOctNovDec
2025 JanFebMarAprMayJunJulAugSepOctNovDec
2026 JanFebMarAprMayJunJulAugSepOct

Hover or focus a month to read it.

No visit on record Visited, nothing cited A stronger orange is more serious, on its source’s own levels, read onto four bands: from the least serious it publishes to the most
Source:

Hearth Record drew this from the dates and levels in the source’s own records.

Each deficiency, as cited

Rule titles as CMS’s inspectors cite them, set in sentence case.

Source:

CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.

Feb 4, 2026: standard inspection1 deficiency
  • Assess B/P & Fluid Management Needs

    The inspectors’ words, 378 words

    “PA-ASSESS B/P, FLUID MANAGEMENT NEEDS CFR(s): 494.80(a)(2) The patient’s comprehensive assessment must include, but is not limited to, the following: Blood pressure, and fluid management needs. This Standard is not met as evidenced by: 30377 Based on review of medical records, policy and procedures, and staff interview, the facility staff failed to ensure that patient vital signs that fell outside of the facility’s set parameters were reported to the Registered Nurse and/or physician for further assessment and intervention in 1 (Patient #1) of 7 patient medical records reviewed. The facility staff failed to follow the ‘Notification Parameters for Weatherford Revised Date 03/24/2025.” Findings include: Review of hemodialysis flow sheets on 02/03/2026 in the facility conference room revealed the following: Patient #1 Flow Sheet dated 01/02/2026 Dialysis Prescription Treatment Time: 3.5 hours Pre Treatment Vitals: Time: 03:36 PM Blood Pressure: 80/58 Heart Rate: 112 Post Treatment Vitals: Time: 06:52 PM Blood Pressure: 108/62 Heart Rate: 116 There was no documentation provided at time of review that the registered nurse was notified prior to the dialysis technician initiating the dialysis treatment that the patient’s blood pressure and heart rate fell outside of facility’s acceptable parameters. Flow Sheet dated 01/12/2026 Dialysis Prescription Treatment Time: 3.5 hours Pre Treatment Vitals: Time: 04:01 PM Blood Pressure: 152/88 Heart Rate: 116 Post Treatment Vitals: Time: 07:42 PM Blood Pressure: 116/64 Heart Rate: 107 There was no documentation provided at time of review that the registered nurse was notified prior to the dialysis technician initiating the dialysis treatment that the patient’s heart rate fell outside of facility’s acceptable parameters. A review of the facility policy, “Notification Parameters For WEATHERFORD REVISED DATE 03/24/2025.” stated that the following parameters were provided for the direct patient care staff to give guidance when a registered nurse needed to evaluate the patient status. Pre Treatment: Systolic Blood Pressure greater than 180 Diastolic Blood Pressure greater than 100 Systolic Blood Pressure less than 100 Diastolic Blood Pressure less than 50 DO NOT START TREATMENT UNTIL APPROVED BY THE CHARGE NURSE Heart Rate greater than 100 Heart Rate less than 50 An interview conducted on 02/03/2026 at 12:30 PM with Staff Member #5, following her own review of the findings, revealed she was unaware of the discrepancies found in the flow sheets.”

    Rule V0504. Standard-level.

Mar 13, 2025: standard inspection8 deficiencies
  • Cfc - Patient Assessment

    “CFC-PATIENT ASSESSMENT CFR(s): 494.80 This Condition is not met as evidenced by: 30377 Based on review of hemodialysis flow sheets and staff interview the nursing staff failed to evaluate the appropriateness of the dialysis prescription by failing to complete a post dialysis assessment. Based on review of medical records and staff interview the facility’s nursing staff failed to address elevated potassium lab values and adjust dialysate formula per the physician order in a timely manner. Refer to tags V 0504 and V0505”

    Rule V0500. Condition-level.

  • Cfc - Responsibilities Of The Medical Director

    The inspectors’ words, 168 words

    “CFC-RESPONSIBILITIES OF THE MEDICAL DIRECTOR CFR(s): 494.150 This Condition is not met as evidenced by: 30377 Based on review of hemodialysis flow sheets and staff interview the nursing staff failed to evaluate the appropriateness of the dialysis prescription by failing to complete a post dialysis assessment. Based on review of medical records and staff interview the facility’s nursing staff failed to address elevated potassium lab values and adjust dialysate formula per the physician order in a timely manner. Based on review of Quality Assessment and Improvement Performance (QAPI) meeting minutes and staff interview the medical director failed to ensure that all required members attending the monthly QAPI meetings. The medical director failed to ensure that the facility analyze, make recommendation, and develop action plans including root cause analysis to minimize events that occurred in the facility and take appropriate action to reduce future events. These deficient practices identified have the potential to cause harm to all patients at the facility. Refer to tags V 0504, V0505, and V0712”

    Rule V0710. Condition-level.

  • Ic - Sanitary Environment

    The inspectors’ words, 299 words

    “IC-SANITARY ENVIRONMENT CFR(s): 494.30 The dialysis facility must provide and monitor a sanitary environment to minimize the transmission of infectious agents within and between the unit and any adjacent hospital or other public areas. This Standard is not met as evidenced by: 30377 Based on observation and staff interview the facility staff failed to ensure a clean and sanitary environment was monitored and maintained in the in-center treatment area. This deficient practice had the likelihood to result in the transmission of infectious agents within the facility and between patients, staff members, and members of the public. During a tour of the facility’s clinical areas with Staff # 1 on 03/10/25 at 1:00 PM and again on 3/12/25 at 5:02 PM the surveyor observed the following infection control issues: In-Center Treatment Area: Opened glove boxes stored on small shelves directly behind the dialysis station. Manual blood pressure stand base, IV pole base, and crash cart lower drawer with excessive dust build up. Used gowns stored on hooks that allowed the gown to touch the floor. Multiple dialysis machines with light yellow / brown stains at the base of the machine Multiple blood pressure cuffs attached to the dialysis machine observed with excessive lent build up. Metal aspect of the dialysis chair with dust build up observed on 2 out of 3 chairs. Full trash cans stored alongside clean dialysis chairs (inside the dialysis station) at the end of the treatment day. The full trash can was stored in the dialysis station for the housekeeper to empty after the dialysis unit is closed. An interview was conducted with Staff # 1 on 03/12/2025 at 5:30 PM confirmed the infection control issues found in the clinical areas of the facility. Staff # 1 was present during the tour of the clinical areas.”

    Rule V0111. Standard-level.

  • Ic - Wear Gloves/Hand Hygiene

    The inspectors’ words, 270 words

    “IC-WEAR GLOVES/HAND HYGIENE CFR(s): 494.30(a)(1) Wear disposable gloves when caring for the patient or touching the patient’s equipment at the dialysis station. Staff must remove gloves and wash hands between each patient or station. This Standard is not met as evidenced by: 30377 Based on direct observation and staff interview the staff failed to ensure their hands were washed or sanitized between glove changes, when moving from station to station, and after touching patients per facility policy. These findings have the likelihood to cause harm by increasing the risk of infection to all patients receiving care at the facility by increasing the potential of cross-contamination between patients. Findings: During observation of care of the facility’s in-center treatment area on 03/12/25 the following was observed: Between 09:55 and 10:05 AM: The patient care technician staff member # 5 was observed multiple times not performing hand hygiene post glove removal and prior to placing on new gloves. At 10:08 AM: Staff # 6 observed gloved assisting patient place on face mask. The staff member removed and disposed of the gloves. She proceeded to the computer cart and placed on new gloves. The staff member did not perform hand hygiene prior to exiting station and after gloves removed. At 10:22 AM: Staff # 4 conducting a pre-assessment with no gloves on. At 10:35 AM: Staff # 4 conducting a pre-assessment with no gloves on. In an interview conducted, with staff #1, on 3/12/25 at 11:00 AM confirmed that staff were required to wash or sanitize hands between glove changes, when moving from station to station, and after touching patients to prevent cross contamination.”

    Rule V0113. Standard-level.

  • Assess B/P & Fluid Management Needs

    The inspectors’ words, 262 words

    “PA-ASSESS B/P, FLUID MANAGEMENT NEEDS CFR(s): 494.80(a)(2) The patient’s comprehensive assessment must include, but is not limited to, the following: Blood pressure, and fluid management needs. This Standard is not met as evidenced by: 30377 Based on review of hemodialysis flow sheets and staff interview the nursing staff failed to evaluate the appropriateness of the dialysis prescription by failing to complete a post dialysis assessment. The findings included: Observation of the in-center treatment floor on 03/12/25 from 09:25 AM to 10:45AM revealed the following: Patient # 2 observed on dialysis treatment with rinse back initiated at 09:42 AM. The patient was observed leaving the in-center area at 09:55 AM with no post assessment being completed by the registered nurse. Patient # 3 observed on dialysis treatment with rinse back initiated at 09:34 AM. The patient was observed leaving the in-center treatment area at 09:46 with no post assessment being completed by the registered nurse. Review of flow sheets dated for 03/12/25 at 3:07 PM revealed that patient #2 and #3 both had post assessments documented including lung field sounds and heart rate and rhythms. An interview conducted with the staff #4 on 03/12/25 at approximately 5:30 PM following her own review of the findings confirmed that she did not assess patient #2 and or #3 prior to their discharge from the facility. Staff #4 confirmed that she documented auscultation of lung fields and heart sounds for patient #2 and #3. Staff # 4 stated she sometimes does not have time to complete post assessments prior to patient being discharged from the facility.”

    Rule V0504. Standard-level.

  • Assess Lab Profile

    The inspectors’ words, 351 words

    “PA-ASSESS LAB PROFILE CFR(s): 494.80(a)(3) The patient’s comprehensive assessment must include, but is not limited to, the following: (3) Laboratory profile, This Standard is not met as evidenced by: 30377 Based on review of medical records and staff interview the facility’s nursing staff failed to address elevated potassium lab values and adjust dialysate formula per the physician order in a timely manner. The findings included: Review of Patient #1’s medical records on 3/12/25 at 10:00 AM in the facility conference room revealed the following elevated potassium levels. Patient # 1 01/20/25 Potassium level was 6.3 02/03/25 Potassium level was 6.9 02/07/25 Potassium level was 6.4 02/17/25 Potassium level was 7.0 03/03/25 Potassium level was 6.7 03/10/25 Potassium level was 6.4 Review of Physician Progress Note revealed the following documentation: 01/08/25 Assessment and Plan: Nutrition: Council patient on low K+ diet, RD to reeducate, Low potassium bath. (To note: The patient was receiving dialysis on a standard dialysis bath) 01/13/25: Assessment and Plan: Nutrition: Talk about low K diet. Other: Patient tolerated dialysis very well. Continue current prescription (To note: The patient remained on a standard dialysis bath) 02/05/25: Assessment and Plan: Nutrition: Talked about the importance of watching potassium intake (To note: The patient remained on a standard dialysis bath) 02/17/25: Assessment and Plan: Nutrition: Talked about the importance of watching potassium intake. 1 K+ bath Re-educate Repeat (To note: The patient remained on a standard dialysis bath) 02/24/25: Assessment and Plan: Nutrition: Talked about the importance of watching potassium intake. 1 K+ bath Re-educate Repeat (To note: The patient remained on a standard dialysis bath) As of 3/12/25 the patient remained on standard dialysis bath and not a low potassium bath as directed by the physician in January and February 2025. Interview conducted with Staff #1 on 3/12/25 at 1:15 PM after her own review confirmed the above findings. Staff # 1 stated that she does not always have time to review labs timely. Staff #1 confirmed that the attending physician documented in January 2025 and February 2025 that the patient should receive dialysis on a low potassium (1K+) bath.”

    Rule V0505. Standard-level.

  • Measure, Analyze And Track Quality Indicators

    The inspectors’ words, 309 words

    “QAPI-MEASURE/ANALYZE/TRACK QUAL INDICATORS CFR(s): 494.110(a)(2) The dialysis facility must measure, analyze, and track quality indicators or other aspects of performance that the facility adopts or develops that reflect processes of care and facility operations. These performance components must influence or relate to the desired outcomes or be the outcomes themselves. This Standard is not met as evidenced by: 30377 Based on review of Quality Assessment and Improvement Performance (QAPI) meeting minutes and staff interview the facility failed to analyze, make recommendation, and develop action plans including root cause analysis to minimize events that occurred in the facility and take appropriate action to reduce future events. These deficient practices identified have the potential to cause harm to all patients at the facility. Findings were: Review of Quality Assessment and Improvement Performance meeting minutes from February 2024 to January 2025 on 3/12/25 in the facility’s conference room revealed the following: Hospitalization Improvement Plan-January 2025 revealed that from September 2024 to January 2025 the facility’s trend for hospitalization increased month after month. The following was observed. September 2024 eight hospitalizations were identified. October 2024 nine hospitalizations were identified. November 2024 twelve hospitalizations were identified. December 2024 twelve hospitalizations were identified. January 2025 seventeen hospitalizations were identified. There was no documentation presented that the facility conducted a root cause analysis of the hospitalizations. There was no documentation presented that the facility developed action plans to minimize hospitalizations. An interview conducted with the staff # 2 on 3/12/25 at 2:30 PM following her own review of the findings confirmed the above. Staff # 2 confirmed that the facility did not present documentation to demonstrate that a root cause analysis was completed. Staff # 2 also confirmed that action plans were not developed to address the increase in hospitalizations. At the time of the interview no evidence of compliance was presented where non-compliance was found.”

    Rule V0628. Standard-level.

  • Md Resp - Qapi Program

    The inspectors’ words, 385 words

    “MD RESP-QAPI PROGRAM CFR(s): 494.150(a) Medical director responsibilities include, but are not limited to, the following: (a) Quality assessment and performance improvement program. This Standard is not met as evidenced by: 30377 Based on review of Quality Assessment and Improvement Performance (QAPI) meeting minutes and staff interview the medical director failed to ensure that all required members attending the monthly QAPI meetings. The medical director failed to ensure that the facility analyze, make recommendation, and develop action plans including root cause analysis to minimize events that occurred in the facility and take appropriate action to reduce future events. These deficient practices identified have the potential to cause harm to all patients at the facility. Findings were: Review of Quality Assessment and Improvement Performance meeting minutes from February 2024 to January 2025 on 3/12/25 in the facility’s conference room revealed the following: Review of QAPI Meeting Participants and Signatures form revealed the following. QAPI Attendance Sheet dated 02/18/25 (Review of January 2025 data) The Biomed was not in attendance. QAPI Attendance Sheet dated 01/20/25 (Review of December 2024 data) The Registered Dietician, Clinical Coordinator, and Biomed was not in attendance. QAPI Attendance Sheet dated 11/16/24 (Review of October 2024 data) The Biomed was not in attendance. QAPI Attendance Sheet dated 09/27/24 (Review of August 2024 data) The Biomed and Social Worker was not in attendance. Hospitalization Improvement Plan-January 2025 revealed that from September 2024 to January 2025 the facility’s trend for hospitalization increased month after month. The following was observed. September 2024 eight hospitalizations were identified. October 2024 nine hospitalizations were identified. November 2024 twelve hospitalizations were identified. December 2024 twelve hospitalizations were identified. January 2025 seventeen hospitalizations were identified. There was no documentation presented that the facility conducted a root cause analysis of the hospitalizations. There was no documentation presented that the facility developed action plans to minimize hospitalizations. An interview conducted with the staff # 2 on 3/12/25 at 2:30 PM following her own review of the findings confirmed the above. Staff # 2 confirmed that the facility did not present documentation to demonstrate that a root cause analysis was completed. Staff # 2 also confirmed that action plans were not developed to address the increase in hospitalizations. At the time of the interview no evidence of compliance was presented where non-compliance was found.”

    Rule V0712. Standard-level.

All 3 inspections in the last three years
Inspections on record
DateVisitWhat the record says
Feb 4, 2026Standard inspection1 deficiency cited
Mar 13, 2025Complaint inspectionNo deficiencies cited
Mar 13, 2025Standard inspection8 deficiencies cited

Is it certified?

  • Medicare-certified dialysis facility, certified or last recertified on Jan 7, 2016.
  • Run for profit.
  • Cited at in the last three years: it didn’t meet a whole condition of Medicare’s rules for dialysis facilities.
  • Chain: DaVita.
Source:

CMS, Dialysis Facility - Listing by Facility. Released Jul 15, 2026. Updated quarterly.

CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.

Has it been penalized?

  • CMS doesn’t publish fines or other penalties for dialysis facilities.
  • None of the deficiencies cited in the last three years came from an inspection that included a complaint investigation.
Source:

CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.

What does it offer?

  • Offers in-center hemodialysis and peritoneal dialysis.
  • Doesn’t offer home hemodialysis training and a shift starting at 5 p.m. or later.
  • 13 dialysis stations.
  • CMS doesn’t publish staffing levels for dialysis facilities.
Source:

CMS, Dialysis Facility - Listing by Facility and Patient survey (ICH CAHPS) - Facility. Released Jul 15, 2026. Updated quarterly.

Who owns it?

  • Part of the DaVita chain, as CMS lists it.
  • CMS publishes no owners file for dialysis facilities, so no other owner is named.
Source:

CMS, Dialysis Facility - Listing by Facility. Released Jul 15, 2026. Updated quarterly.

How do patients fare?

  • CMS rates it 2 of 5 stars (Jan 1, 2021 to Dec 31, 2024).
  • Compared by CMS with what it expects for the facility’s patients: patient survival, as expected; hospital admissions, as expected; readmissions to hospital, as expected; blood transfusions, as expected; emergency department visits, as expected; emergency department visits within 30 days of a hospital stay, as expected; bloodstream infections, as expected; patients dialysing through a fistula, as expected; patients put on a kidney transplant waitlist in their first year of dialysis, as expected; patients on a kidney transplant waitlist, as expected.
  • CMS gives no : “Too few completed survey responses to report.”
Source:

CMS, Dialysis Facility - Listing by Facility and Patient survey (ICH CAHPS) - Facility. Released Jul 15, 2026. Updated quarterly.

Ratings and measures, as published
MeasureRating
Star ratingCMS’s star rating for dialysis facilities, 1 to 52 of 5
Patient survey ratingCMS star rating from its survey of the facility’s in-center hemodialysis patients (ICH CAHPS), 1 to 5Not rated

How does it compare nearby?

  • Of the 3 dialysis facilities CMS lists in Parker County, 3 have a star rating from CMS: 1 rated 3 of 5, 1 rated 2 of 5, 1 rated 1 of 5.
  • CMS rates this one 2 of 5.
Source:

CMS, Dialysis Facility - Listing by Facility. Released Jul 15, 2026. Updated quarterly.

2 compared
PlaceStar rating
Fkc Weatherford3
Usrc Weatherford1

What the record doesn’t say

  • CMS doesn’t publish fines or other penalties for dialysis facilities, so none are shown.
  • Only complaints that led to a citation appear; complaints that didn’t aren’t published.
  • QCOR says it has no dialysis inspection reports after February 19, 2026, while it moves to a new system: a later inspection is not shown yet.
  • CMS doesn’t publish staffing levels for dialysis facilities.
  • CMS publishes no owners file for dialysis facilities: the chain it lists is the only owner named.

Sources

If you believe something here is wrong, a correction starts with the agency whose record this copies: CMS. CMS’s own record is on Care Compare. If Hearth Record copied something wrongly, it will fix it and log the correction publicly, with its date: how corrections work.

Source:

This copy of the record was made on Oct 30, 2026.

From the facility

The public record above comes first. Anything the facility adds will appear here, below it, and say who wrote it.

Replies

None. Replies aren’t open yet. When they open, the facility will be able to answer any finding for free, and the reply will show beside that finding, unedited and dated.

Paid listing

None. Paid listings aren’t open yet. When they open, anything paid for will say “Paid by the facility”, and paying will never change a finding, a rating or the order of results.

How to read a record

Four things every record does, shown on an example record made up for this guide.

An example record, made up for this guide

An example nursing home

Made up for this guide: no real place is shown

Not fully inspected in over two years (CMS flag)

11 health citations at the latest inspection cycle

The state average is 14.3.

Source:

CMS, State and US Averages and Health Deficiencies. Released Oct 8, 2026. Updated monthly.

From the homeNone yet. Replies and paid listings aren’t open, and when they open they will sit here, below the record.

1 of 4

Every fact names its source.

Who published it, when, and how often it changes sit beside each fact, with a link to the agency’s own file.

Sign in

A free account keeps your watch list, shortlists, comparisons and saved searches on every device, and can email you when something you watch changes. Browsing never needs one.