Davita Central Dallas Dialysis

A dialysis facility in Dallas, Texas 75231

9500 North Central Expressway, Suite #102, Dallas, Texas 75231. (214) 739-3004.

CMS’s own record, on Care Compare

Watch and the shortlist are kept with a free account, on every device. Your watch list. CMS’s own record is on Care Compare.

The short answer

Record last released by CMS on Oct 28, 2026.

The last 24 months 4 deficiencies in 1 month of the last 36. Last cited Jan 2024. Most serious: Standard-level. Every month

Each figure’s source sits beside it, in its section below.

What these words mean3
Star ratings
CMS rates some kinds of place from 1 to 5 stars, more stars meaning better on CMS’s own measures for that kind: for a nursing home, its health inspections, staffing and quality measures. A rating is CMS’s summary of those measures; it doesn’t promise good care. Source: CMS, Care Compare and the Five-Star Quality Rating System.
Inspection (survey)
A visit by state inspectors, often unannounced, who check a place against the rules it must meet. For nursing homes and other places Medicare pays, CMS calls these visits surveys: a standard survey of a nursing home comes at least every 15 months, and a complaint survey whenever a complaint calls for one. Source: CMS; 42 CFR 488.308.
Deficiency, citation, violation
What inspectors write up when a place didn’t meet a rule: the rule, what they saw, and when. CMS calls it a deficiency; states may say citation or violation. It is the inspectors’ finding, not a court’s, and the place is usually asked for a plan to correct it. Source: CMS, statement of deficiencies (Form CMS-2567); each state’s licensing agency.

What did inspectors find?

The last inspection on record was on Jan 17, 2024: a complaint and standard inspection.

4 deficiencies cited in the last three years.

Source:

CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.

When those deficiencies happened

4 deficiencies in 1 month of the last 36. Last cited Jan 2024. Most serious: Standard-level. The last 3 years, to Oct 30, 2026.

4 deficiencies by month over the last 3 years. Each cell is one month.
JanFebMarAprMayJunJulAugSepOctNovDec
2023 NovDec
2024 JanFebMarAprMayJunJulAugSepOctNovDec
2025 JanFebMarAprMayJunJulAugSepOctNovDec
2026 JanFebMarAprMayJunJulAugSepOct

Hover or focus a month to read it.

No visit on record Visited, nothing cited A stronger orange is more serious, on its source’s own levels, read onto four bands: from the least serious it publishes to the most
Source:

Hearth Record drew this from the dates and levels in the source’s own records.

Each deficiency, as cited

Rule titles as CMS’s inspectors cite them, set in sentence case.

Source:

CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.

Jan 17, 2024: complaint and standard inspection4 deficiencies
  • Ic - Clean, Disinfect Surfaces & Equipment/Written Protocols

    The inspectors’ words, 427 words

    “IC-DISINFECT SURFACES/EQUIP/WRITTEN PROTOCOL CFR(s): 494.30(a)(4)(ii) [The facility must demonstrate that it follows standard infection control precautions by implementing- (4) And maintaining procedures, in accordance with applicable State and local laws and accepted public health procedures, for the-] (ii) Cleaning and disinfection of contaminated surfaces, medical devices, and equipment. This Standard is not met as evidenced by: 22676 Based on observation, interview, facility policy review and review of Centers for Disease Control (CDC) guidance, the facility failed to ensure that the 13 out of 16 wall boxes (dispensing outlets) at dialysis stations and 13 out of 16 dialysis machines was cleaned and the buildup of white crystals and yellow substance removed. This deficient practice had the potential to cause bacteria to grow in the wall boxes and cause harm by infecting the 39 patients receiving in-center hemodialysis at the facility. Findings included: Observation of the wall boxes on 01/15/24 at 2:25 PM, at each dialysis station, stations numbered 1, 2, 3, 6, 7, 8, 9, 10, 11, 12, 13, 14 and 16 revealed a dark yellow sediment with white sediment build-up on the wall boxes. Observations on 01/15/24 at 2:25 PM revealed that dialysis machines on the treatment floor numbered 1, 2, 3, 4, 6, 7, 9, 11, 13, 16, 17, 18 and 19 had a dark orange build up on the front and the bottom. During an interview on 01/15/24 at 2:45 PM, the Biomed stated that he/she did not know when the wall boxes were to be cleaned. He/she confirmed all 13 wall boxes were visibly dirty with white sediments and dark yellow build up and all 13 dialysis machines were visually dirty with a dark yellow build up. Review of facility policy titled, “Infection Control for Dialysis Facilities,” dated April 23, indicated, “. . .equipment including the dialysis delivery system ... wiped clean with bleach solution of the appropriate strength ...thought out the workday and after each treatment. . .” Review of the “CDC Dialysis Safety” located on the CDC website at www.cdc.gov titled “Wall boxes and Drains” indicated, “All box surfaces should be disinfected at least daily (e.g., at the end of the day after all patients have dialyzed); cleaning and disinfection might be needed more frequently (e.g., when visibly dirty). Cleaning and disinfection of the wall box should be performed after the patient has left the station, and not during patient care activities. . .More than one disinfectant wipe or application may be needed to ensure all wall box surfaces are visibly wet with disinfectant to achieve contact time specified by the manufacturer.””

    Rule V0122. Standard-level. From a complaint.

  • Mixing Sys - Follow Dfu/Monitor/Pm/Log/Sanitization

    The inspectors’ words, 308 words

    “MIX SYS-DFU/MONITOR/PM/LOG/SANITIZE CFR(s): 494.40(a) 5.4.4.1 Mixing systems: follow DFU/monitor/PM/log/sanitization If a concentrate mixing system is used, the preparer should follow the manufacturer’s instructions for mixing the powder with the correct amount of water. If a concentrate mixing system is used, the number of bags or the weight of powder added should be determined and recorded. Manufacturer’s recommendations should be followed regarding any preventive maintenance and sanitization procedures. Records should be maintained indicating the date, time, person performing the procedure, and results (if applicable). 6.4.1 Mixing systems: Systems for preparing either bicarbonate or acid concentrate from powder should be monitored according to the manufacturer’s instructions. This Standard is not met as evidenced by: 22676 Based on interview, document review, and policy review, the facility failed to change the Granuflo (a type of acid base used in dialysis treatments) mixing tank filter after the sixth batch. This had the potential to cause harm to all 76 in-center hemodialysis patients receiving care at the facility. Findings include: Review of the facility’s form titled, “Granuflo Batch Procedure Record,” dated revised October 2023, “ indicated, “ ...replace filter after 6 [sic] batches.” Review of the record for ten batches mixed from 10/26/23 to 12/21/23 revealed there were a total of eight batches mixed prior to the filter change. Documentation revealed there were a total of eight batches made between filter changes. During an interview with the Biomed on 01/17/23 at 10:00 AM, confirmed there was no evidence the mixing filter had been changed as required, and he/she agreed that the facility did not have a system to track when the filter was changed. Review of the facility’s policy titled, “Granuflo Concentrate Dissolution Unit Mixing Procedure,” dated April 2023, failed to include the filter changing schedule or a procedure to document that the filter had been changed other than on the Batch Productions Record.”

    Rule V0226. Standard-level. From a complaint.

  • Mixing Systems - Permanent Record/Verification Testing

    The inspectors’ words, 568 words

    “MIXING SYSTEMS-PERM RECORD/VERIF TEST CFR(s): 494.40(a) 5.4.4.1 Mixing systems: perm record/verification testing In addition to container labeling, there should be permanent records of batches produced. These records should include the concentrate formula produced, the volume of the batch, the lot numbers of powdered concentrate packages, the manufacturer of the powdered concentrate, the date and time of mixing, any test results, the person performing the mixing, the person verifying mixing and test results, and the expiration date (if applicable). 6.4.1 Mixing systems Acid and bicarbonate concentrates may be tested by using conductivity or by using a hydrometer. Concentrates should not be used or transferred to holding tanks or distribution systems until all tests are completed. The test results and verification that they meet all applicable criteria should be recorded and signed by the individuals performing the tests. This Standard is not met as evidenced by: 22676 Based on observation, record review, interview, review of the facility’s policy, the facility staff failed to test the bicarbonate solution (part of the solutions used in the dialysis treatment) prior to releasing the solution to the treatment floor as required. This s deficient practice had the likelihood to affect all 38 in-center hemodialysis patients receiving care at the facility. Findings include: During a tour of the water room on 01/16/24 at 10:00 AM, revealed the bicarbonate tank sign contained only the date and time of mixing and the initial of the staff member mixing the bicarbonate. There was no conductivity or specific gravity recorded. The Biomed confirmed the sign did not contain conductivity or specific gravity. A review of the bicarbonate mixing log from 10/02/23 through 01/16/24 revealed there was no documentation of conductivity or specific gravity on the log. An interview with the Biomed on 01/16/24 at 10:00 AM confirmed staff doesn’t record the testing of the bicarb on log, and they don’t test the bicarbonate prior to releasing the solution to the floor. The Biomedical Technician confirmed the manufacturer did not specify if a conductivity of specific gravity should be done or not and he agreed that if the manufacturer did not set a range, the facility should set the range for the staff to follow. A review of Fresenius Dry Bicarbonate bag revealed the manufacture had no recommendations regarding the testing of reconstituted bicarbonate concentrate for conductivity, specific gravity, or pH (acidity or alkalinity of a solution). A review of the facility’s policy titled, “Better Water-Central Bicarb Mixing and Delivery” dated 05/08/13, revealed the following, “. .10. Test sample of solution from valve B9 for proper concentrations per facility protocol, if applicable ...” The federal regulations adopted the ANSI/AAMIRD52:2004 which gives guidance on the mixing of Bicarbonate and revealed the following, “The mixing logs must demonstrate complete documentation of this required information. Test results may include conductivity or specific gravity. Facility policy must stipulate the expected ranges for the test(s) used to verify correct mixing. Standards used to calibrate the instrument used to measure conductivity should encompass the expected results; for example, it would be unacceptable to use a “14” standard for an expected result of “70”. . .Verifying mixing and test results” means the staff member performing this task checks the results against the expected ranges for the test and does not release mixtures for use that test outside those ranges. The facility failed to have a policy that sets the test range for the facility staff to follow.”

    Rule V0229. Standard-level. From a complaint.

  • Pe - Equipment Maintenance - Manufacturer’S Dfu

    The inspectors’ words, 248 words

    “PE-EQUIPMENT MAINTENANCE-MANUFACTURER’S DFU CFR(s): 494.60(b) The dialysis facility must implement and maintain a program to ensure that all equipment (including emergency equipment, dialysis machines and equipment, and the water treatment system) are maintained and operated in accordance with the manufacturer’s recommendations. This Standard is not met as evidenced by: 22676 Based on review of glucometer logs, interview, facility policy review, and review of manufacturer’s instructions, the facility failed to ensure the glucometers were in the control range and follow manufacturer’s instructions for one of one glucometer used in the facility. This had the potential to provide inaccurate glucose results that could result in mistreated blood glucose levels to all 40 patients receiving care at the facility. Findings include: Review of Blood Glucose logs for the facility (no meter number listed) from 11/01/23 through 01/08/24 revealed the acceptable low blood glucose control range should be 94-126. On 12/30/23, the recorded low control was 130. During an interview on 01/16/24 at 1:35 PM, with the Facility Administrator he/she confirmed the staff did not repeat calibration of the abnormal low testing level. Review of the facility’s policy titled, “EmbracePRO Blood Glucose Monitoring System Quality Control” dated September 2020, revealed, “. . . 16. If control results fall outside the acceptable range the test must be repeated.” Review of the “Embrace Pro” blood glucose monitoring system manufactures instruction revision date 09/2020 revealed, “ ...p. eleven, if the “test fall outside the range printed on the test strip vial, repeat the test ...””

    Rule V0403. Standard-level. From a complaint.

The one inspection in the last three years
Inspections on record
DateVisitWhat the record says
Jan 17, 2024Complaint and standard inspection4 deficiencies cited

Is it certified?

  • Medicare-certified dialysis facility, certified or last recertified on Mar 9, 2010.
  • Run for profit.
  • No deficiency on record in the last three years.
  • Chain: DaVita.
Source:

CMS, Dialysis Facility - Listing by Facility. Released Jul 15, 2026. Updated quarterly.

CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.

Has it been penalized?

  • CMS doesn’t publish fines or other penalties for dialysis facilities.
  • 4 deficiencies cited in the last three years came from inspections that included a complaint investigation.
Source:

CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.

What does it offer?

  • Offers in-center hemodialysis, peritoneal dialysis and home hemodialysis training.
  • Doesn’t offer a shift starting at 5 p.m. or later.
  • 16 dialysis stations.
  • CMS doesn’t publish staffing levels for dialysis facilities.
Source:

CMS, Dialysis Facility - Listing by Facility and Patient survey (ICH CAHPS) - Facility. Released Jul 15, 2026. Updated quarterly.

Who owns it?

  • Part of the DaVita chain, as CMS lists it.
  • CMS publishes no owners file for dialysis facilities, so no other owner is named.
Source:

CMS, Dialysis Facility - Listing by Facility. Released Jul 15, 2026. Updated quarterly.

How do patients fare?

  • CMS rates it 2 of 5 stars (Jan 1, 2021 to Dec 31, 2024).
  • Compared by CMS with what it expects for the facility’s patients: patient survival, as expected; hospital admissions, as expected; readmissions to hospital, as expected; blood transfusions, as expected; emergency department visits, as expected; emergency department visits within 30 days of a hospital stay, as expected; bloodstream infections, better than expected; patients dialysing through a fistula, as expected; patients on a kidney transplant waitlist, as expected.
  • CMS gives no : “Too few completed survey responses to report.”
Source:

CMS, Dialysis Facility - Listing by Facility and Patient survey (ICH CAHPS) - Facility. Released Jul 15, 2026. Updated quarterly.

Ratings and measures, as published
MeasureRating
Star ratingCMS’s star rating for dialysis facilities, 1 to 52 of 5
Patient survey ratingCMS star rating from its survey of the facility’s in-center hemodialysis patients (ICH CAHPS), 1 to 5Not rated

How does it compare nearby?

  • Of the 68 dialysis facilities CMS lists in Dallas County, 64 have a star rating from CMS: 2 rated 5 of 5, 7 rated 4 of 5, 31 rated 3 of 5, 20 rated 2 of 5, 4 rated 1 of 5.
  • CMS rates this one 2 of 5.
Source:

CMS, Dialysis Facility - Listing by Facility. Released Jul 15, 2026. Updated quarterly.

What the record doesn’t say

  • CMS doesn’t publish fines or other penalties for dialysis facilities, so none are shown.
  • Only complaints that led to a citation appear; complaints that didn’t aren’t published.
  • QCOR says it has no dialysis inspection reports after February 19, 2026, while it moves to a new system: a later inspection is not shown yet.
  • CMS doesn’t publish staffing levels for dialysis facilities.
  • CMS publishes no owners file for dialysis facilities: the chain it lists is the only owner named.

Sources

If you believe something here is wrong, a correction starts with the agency whose record this copies: CMS. CMS’s own record is on Care Compare. If Hearth Record copied something wrongly, it will fix it and log the correction publicly, with its date: how corrections work.

Source:

This copy of the record was made on Oct 30, 2026.

From the facility

The public record above comes first. Anything the facility adds will appear here, below it, and say who wrote it.

Replies

None. Replies aren’t open yet. When they open, the facility will be able to answer any finding for free, and the reply will show beside that finding, unedited and dated.

Paid listing

None. Paid listings aren’t open yet. When they open, anything paid for will say “Paid by the facility”, and paying will never change a finding, a rating or the order of results.

How to read a record

Four things every record does, shown on an example record made up for this guide.

An example record, made up for this guide

An example nursing home

Made up for this guide: no real place is shown

Not fully inspected in over two years (CMS flag)

11 health citations at the latest inspection cycle

The state average is 14.3.

Source:

CMS, State and US Averages and Health Deficiencies. Released Oct 8, 2026. Updated monthly.

From the homeNone yet. Replies and paid listings aren’t open, and when they open they will sit here, below the record.

1 of 4

Every fact names its source.

Who published it, when, and how often it changes sit beside each fact, with a link to the agency’s own file.

Sign in

A free account keeps your watch list, shortlists, comparisons and saved searches on every device, and can email you when something you watch changes. Browsing never needs one.