Usrc Tri-County Dialysis
A dialysis facility in Lytle, Texas 78052
19910 Interstate 35 S, Lytle, Texas 78052. (830) 772-5784.
Watch and the shortlist are kept with a free account, on every device. Your watch list. CMS’s own record is on Care Compare.
The short answer
Record last released by CMS on Oct 28, 2026.
- 4of 5 CMS’s star rating
- 3of 5 patient survey rating
- 1 deficiency cited in the last three years
- 25 dialysis stations
Each figure’s source sits beside it, in its section below.
What these words mean3
- Star ratings
- CMS rates some kinds of place from 1 to 5 stars, more stars meaning better on CMS’s own measures for that kind: for a nursing home, its health inspections, staffing and quality measures. A rating is CMS’s summary of those measures; it doesn’t promise good care. Source: CMS, Care Compare and the Five-Star Quality Rating System.
- Inspection (survey)
- A visit by state inspectors, often unannounced, who check a place against the rules it must meet. For nursing homes and other places Medicare pays, CMS calls these visits surveys: a standard survey of a nursing home comes at least every 15 months, and a complaint survey whenever a complaint calls for one. Source: CMS; 42 CFR 488.308.
- Deficiency, citation, violation
- What inspectors write up when a place didn’t meet a rule: the rule, what they saw, and when. CMS calls it a deficiency; states may say citation or violation. It is the inspectors’ finding, not a court’s, and the place is usually asked for a plan to correct it. Source: CMS, statement of deficiencies (Form CMS-2567); each state’s licensing agency.
What did inspectors find?
The last inspection on record was on May 8, 2025: a standard inspection.
1 deficiency cited in the last three years.
CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.
When those deficiencies happened
1 deficiency in 1 month of the last 36. Last cited May 2025. Most serious: Standard-level. The last 3 years, to Oct 30, 2026.
| Jan | Feb | Mar | Apr | May | Jun | Jul | Aug | Sep | Oct | Nov | Dec | |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 2023 | Nov | Dec | ||||||||||
| 2024 | Jan | Feb | Mar | Apr | May | Jun | Jul | Aug | Sep | Oct | Nov | Dec |
| 2025 | Jan | Feb | Mar | Apr | May | Jun | Jul | Aug | Sep | Oct | Nov | Dec |
| 2026 | Jan | Feb | Mar | Apr | May | Jun | Jul | Aug | Sep | Oct |
Hover or focus a month to read it.
Hearth Record drew this from the dates and levels in the source’s own records.
Each deficiency, as cited
Rule titles as CMS’s inspectors cite them, set in sentence case.
CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.
May 8, 2025: standard inspection1 deficiency
-
Ic - Clean, Disinfect Surfaces & Equipment/Written Protocols
The inspectors’ words, 1,478 words
“IC-DISINFECT SURFACES/EQUIP/WRITTEN PROTOCOL CFR(s): 494.30(a)(4)(ii) [The facility must demonstrate that it follows standard infection control precautions by implementing- (4) And maintaining procedures, in accordance with applicable State and local laws and accepted public health procedures, for the-] (ii) Cleaning and disinfection of contaminated surfaces, medical devices, and equipment. This Standard is not met as evidenced by: 34839 Based on observation, record review, and staff interview, the facility staff failed to demonstrate standard infection control precautions through the cleaning and disinfection of contaminated surfaces and equipment within the in-center treatment area. This deficient practice had the likelihood to cause harm toall 71 inventer hemodialysis patients, staff members, and the public by increasing the risk of transmission of infectious agents within the facility. Findings include: Treatment area observations 5/7/25 from 8:51AM until 9:33AM During a tour of the facility’s in-center treatment area with Staff # 1 on 05/07/2025 at 08:55 AM, the surveyor observed the following infection control issues, The surveyor observed 24 out of 24 wall boxes with a build-up of acid and bicarbonate splatter inside of them and on the wall surrounding the wall boxes. The wall boxes are to be cleaned and disinfected at the end of each patient treatment according to facility policy. A drawer in the treatment area had an open box of gauze with pens in it. Surveyor asked what the open gauze was for and S#2 stated “It’s for the fistula dressing after treatment.” Surveyor asked “ you don’t use sterile gauze? S#2 stated “No, we only use sterile gauze for the catheters.” Surveyor stated “Well, if this is a clean supply drawer why are you storing dirty pens with the clean supplies?” S#2 removed the pens from the drawer. Staff # 3 was observed setting up machine #9 at dialysis station #9. Surveyor asked S#3 if the station and machine were clean. S#3 responded “yes” . Surveyor noted a white dried substance on top of the dialysis machine, dust behind the machine and white streaks down the right side of the machine as well as a heavy build up of a white substance at the Hanson port. Surveyor donned gloves with S#1 and got 4 disposable bleach clothes, surveyor was able to wipe away the dust and the white substances noted above. Staff # 3 disinfected the dialysis recliner, and the surveyor observed white splatters on the left side of the which the surveyor was able to wipe away. S#3 confirmed the above findings and redirected all staff to disinfect the entire dialysis station. Machine #8 had a heavy build up of a rust colored substance in the Hanson holder. Machine #15 had a heavy build up of a white substance in the Hanson holder. Staff #4 at 9:00AM performed hand sanitization with hand sanitizer and used hand sanitizer to wipe and disinfect stethoscope. Staff #4 at 9:18AM at machine 14 station 6 disconnected patient from dialysis treatment. Staff #4 stethoscope touched patient chair side table while Staff #4 disconnected patient. At 9:22AM Staff #4 performed hand sanitization with hand sanitizer and used hand sanitizer to wipe and disinfect stethoscope. Interview with Staff #1 on 5/7/25 at 9:26AM, surveyor asked what disinfectant is used for stethoscopes between patients. Staff #1 answered “Bleach.” Surveyor said it was observed Staff #4 used hand sanitizer twice to disinfect stethoscope. Staff #1 stated “No, no, they shouldn’t use that.” Policy: Infection Control and Precautions for All Patients Policy # C-IC-0010 Revision Date: 07/2023 Policy reads in part: 13. Supplies: Items taken into the dialysis station will either be disposed of, dedicated for use only on a single patient or cleaned and disinfected before being taken to a common clean area or used on another patient. Treatment area observations 5/7/25 from 8:51AM until 9:33AM. Observation of water treatment room on 5/7/25 from 9:34AM until 9:41AM Findings incluced: Observation in the facility water room 4 of the 5 critic acid jugs with wands were noted to have dust and a dark rust colored build up on the base of the up take wands. At the time of observations, S#5 stated these should be cleaned every week or week and a half. A review of the facility’s policy, “Disinfection and Cleaning of Dialysis Machine Equipment” with a revision date of 07/2023 revealed, “PURPOSE: To provide guidance on proper disinfection of the dialysis station, machine, equipment, and surrounding surfaces with the appropriate method prevent the transmission of disease/infection to the dialysis population. POLICY: 1. A 1:100 dilution bleach solution will be made daily or per stricter state regulations and discarded at the end of the day. 2. Label the bleach container with concentration, date, time and initials of individual mixing the bleach solution. Both container and lid must be opaque to prevent weakening of the bleach solution. Container will remain covered at all times. 3. The bleach solution will have at least a five (5) minute contact time as per manufacturer’s recommendation for external disinfection of non-disposable items, dialysis machines, dialysis chairs and related surfaces. 4. Complete surface disinfection at the end of each dialysis treatment after the patient has vacated the station. DISINFECTION PROCEDURE: 1. Don full PPE. 2. Follow manufacturer’s instructions for disinfection of the dialysis machine, chair and related equipment. Follow instructions for appropriate disinfectant and appropriate contact lime. 3. After each treatment, remove bloodlines and disposable supplies. Clamps will be removed from the IV pole and disinfected even if not used on the patient. 4. Empty the prime container into a designated dirty sink. Do not empty contents of the prime container in the wall box. 5. Remove gloves, perform hand hygiene, don clean gloves. 6. Obtain at least one (1) clean moistened 1:100 bleach cloth for the machine, one (1) for the chair and one (1) for ancillary equipment (oxygen concentrator/acid jug/TV/TV remote). NOTE: If patient is not sufficiently stable to be moved from the dialysis station, cleaning and disinfection of equipment at the station and preparation for next patient will be delayed until patient can be safely moved outside the station. 7. Clean all external surfaces of the dialysis machine to include top, sides, front and back, BP cuffs and basket; dialysate connectors and lines; hand sanitizer and holder; IV pole, items hanging on pole, attached computer monitors and keyboard/mouse. 8. Disinfect all surfaces of the prime waste container, inside and out, with a moistened 1:100 bleach cloth. 9. Clean counter tops behind patient station. 10. Clean ancillary equipment including but not limited to: oxygen concentrator; acid/bicarb jug (ifapplicable); IV pole/pump (if applicable), emergency cart, AED and suction machine. 11. Clean chair by placing in the reclining position and swing arms out (if applicable) to clean seat, footrest, backrest and sides, armrest, inside of chair arms and chair frame and side tray tables. Return chair to its upright position when cleaning is complete. 12. Visible blood: Utilize a two-step process to clean and disinfect. a. First use a moistened 1:100 bleach cloth to remove the blood; b. Then use a second moistened 1:100 bleach cloth to disinfect the surface. 13. Adhere to appropriate contact time between external disinfection of the machine/chair and set up for the next patient. NOTE: Do not leave wet cleaning/disinfecting agents on B Braun machine monitors. If necessary, use a dry cloth after 5-minute contact time. 14. Clean chairside computer keyboards, computer on wheels (COW), external surfaces of computer stations and wall boxes with individual 1:100 bleach wipes at the end of the day. To prevent any cross contamination, change gloves and perform hand hygiene any time the wall box is touched. Examples: When connecting/disconnecting dialysate lines and after disinfecting the wall box. 15. Disinfect non-disposable medical equipment (e.g., scissors, hemostats in open position and clamps), between uses by fully submerging items and soaking in a 1 :100 bleach solution for at least 5 minutes. a. If an item is visibly soiled, clean with a wet 1:100 bleach cloth prior to submerging in bleach solution. b. After at least a 5-minute contact time, remove items, place in a clean container or on a clean pad and allow to air dry. 16. Place all non-disposable medical equipment in a designated clean area for storage. 17. Internal disinfection of the dialysis machine will be per the technical policy. NOTE: Internal disinfection of the machine can be initiated prior to patient vacating the station. 18. When treating COVID-19 positive patients, thoroughly clean lobby, patient restrooms and all common patient areas after patient vacates each area, no less than after each dialysis shift and at end of day (e.g. performed by facility staff in addition to janitorial personnel) ....” During an interview with Staff # 1 on 05/07/2025 at 11:00 AM, Staff # 1 confirmed the facility’s in-center treatment area infection control issues and said the staff were being in serviced now and all wall boxes and Hanson holders will be cleaned and disinfected.”
The one inspection in the last three years
| Date | Visit | What the record says |
|---|---|---|
| May 8, 2025 | Standard inspection | 1 deficiency cited |
Is it certified?
- Medicare-certified dialysis facility, certified or last recertified on Feb 18, 2005.
- Run for profit.
- No For hospices, home health agencies, hospitals and dialysis facilities, CMS writes deficiencies at two levels. Standard is the usual one; condition-level is the more serious, when a problem is serious enough that the provider doesn’t meet a whole condition of taking part in Medicare. Source: CMS, State Operations Manual. deficiency on record in the last three years.
- Chain: US Renal Care, Inc.
CMS, Dialysis Facility - Listing by Facility. Released Jul 15, 2026. Updated quarterly.
CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.
Has it been penalized?
- CMS doesn’t publish fines or other penalties for dialysis facilities.
- None of the deficiencies cited in the last three years came from an inspection that included a complaint investigation.
CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.
What does it offer?
- Offers in-center hemodialysis.
- Doesn’t offer peritoneal dialysis, home hemodialysis training and a shift starting at 5 p.m. or later.
- 25 dialysis stations.
- CMS doesn’t publish staffing levels for dialysis facilities.
- In CMS’s survey, patients rate its staff 2 of 5.
CMS, Dialysis Facility - Listing by Facility and Patient survey (ICH CAHPS) - Facility. Released Jul 15, 2026. Updated quarterly.
Who owns it?
- Part of the US Renal Care, Inc. chain, as CMS lists it.
- CMS publishes no owners file for dialysis facilities, so no other owner is named.
CMS, Dialysis Facility - Listing by Facility. Released Jul 15, 2026. Updated quarterly.
How do patients fare?
- CMS rates it 4 of 5 stars (Jan 1, 2021 to Dec 31, 2024).
- Compared by CMS with what it expects for the facility’s patients: patient survival, as expected; hospital admissions, as expected; readmissions to hospital, as expected; blood transfusions, as expected; emergency department visits, as expected; emergency department visits within 30 days of a hospital stay, as expected; bloodstream infections, better than expected; patients dialysing through a fistula, as expected; patients put on a kidney transplant waitlist in their first year of dialysis, as expected; patients on a kidney transplant waitlist, as expected.
- Patients rate it 3 of 5 in CMS’s survey of in-center hemodialysis patients (40 interviews, Oct 18, 2024 to Jul 11, 2025): 64% rated the facility 9 or 10 out of 10.
CMS, Dialysis Facility - Listing by Facility and Patient survey (ICH CAHPS) - Facility. Released Jul 15, 2026. Updated quarterly.
| Measure | Rating |
|---|---|
| Star ratingCMS’s star rating for dialysis facilities, 1 to 5 | 4 of 5 |
| Patient survey ratingCMS star rating from its survey of the facility’s in-center hemodialysis patients (ICH CAHPS), 1 to 5 | 3 of 5 |
How does it compare nearby?
- Of the 3 dialysis facilities CMS lists in Atascosa County, 3 have a star rating from CMS: 1 rated 5 of 5, 2 rated 4 of 5.
- CMS rates this one 4 of 5.
CMS, Dialysis Facility - Listing by Facility. Released Jul 15, 2026. Updated quarterly.
| Place | Star rating |
|---|---|
| Fresenius Medical Care Tri City | 5 |
| Usrc Atascosa County Dialysis | 4 |
What the record doesn’t say
- CMS doesn’t publish fines or other penalties for dialysis facilities, so none are shown.
- Only complaints that led to a citation appear; complaints that didn’t aren’t published.
- QCOR says it has no dialysis inspection reports after February 19, 2026, while it moves to a new system: a later inspection is not shown yet.
- CMS doesn’t publish staffing levels for dialysis facilities.
- CMS publishes no owners file for dialysis facilities: the chain it lists is the only owner named.
Sources
-
Centers for Medicare & Medicaid Services, Dialysis Facility - Listing by Facility (23ew-n7w9).
Released Jul 15, 2026 and checked Oct 30, 2026. Updated quarterly. Public domain (U.S. Government work).
-
Centers for Medicare & Medicaid Services, Patient survey (ICH CAHPS) - Facility (59mq-zhts).
Released Jul 15, 2026 and checked Oct 30, 2026. Updated quarterly. Public domain (U.S. Government work).
-
Centers for Medicare & Medicaid Services, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies (ESRD_2567s_2018_to_2026YTD.xlsx).
Released Oct 28, 2026 and checked Oct 30, 2026. Updated monthly. Public domain (U.S. Government work).
If you believe something here is wrong, a correction starts with the agency whose record this copies: CMS. CMS’s own record is on Care Compare. If Hearth Record copied something wrongly, it will fix it and log the correction publicly, with its date: how corrections work.
This copy of the record was made on Oct 30, 2026.
From the facility
The public record above comes first. Anything the facility adds will appear here, below it, and say who wrote it.
Replies
None. Replies aren’t open yet. When they open, the facility will be able to answer any finding for free, and the reply will show beside that finding, unedited and dated.
Paid listing
None. Paid listings aren’t open yet. When they open, anything paid for will say “Paid by the facility”, and paying will never change a finding, a rating or the order of results.