Hearth Record

Grand Prairie Dialysis Center Inc.

A dialysis facility in Grand Prairie, Texas 75051

550 S Carrier Parkway, Suite 450, Grand Prairie, Texas 75051. (972) 237-2400.

CMS’s own record, on Care Compare

Watch and the shortlist are kept with a free account, on every device. Your watch list. CMS’s own record is on Care Compare.

The short answer

Record last released by CMS on Oct 28, 2026.

The last 24 months 3 deficiencies in 1 month of the last 36. Last cited Sep 2025. Most serious: Condition-level. Every month

Each figure’s source sits beside it, in its section below.

What these words mean4
Star ratings
CMS rates some kinds of place from 1 to 5 stars, more stars meaning better on CMS’s own measures for that kind: for a nursing home, its health inspections, staffing and quality measures. A rating is CMS’s summary of those measures; it doesn’t promise good care. Source: CMS, Care Compare and the Five-Star Quality Rating System.
Inspection (survey)
A visit by state inspectors, often unannounced, who check a place against the rules it must meet. For nursing homes and other places Medicare pays, CMS calls these visits surveys: a standard survey of a nursing home comes at least every 15 months, and a complaint survey whenever a complaint calls for one. Source: CMS; 42 CFR 488.308.
Deficiency, citation, violation
What inspectors write up when a place didn’t meet a rule: the rule, what they saw, and when. CMS calls it a deficiency; states may say citation or violation. It is the inspectors’ finding, not a court’s, and the place is usually asked for a plan to correct it. Source: CMS, statement of deficiencies (Form CMS-2567); each state’s licensing agency.
Condition-level deficiency
For hospices, home health agencies, hospitals and dialysis facilities, CMS writes deficiencies at two levels. Standard is the usual one; condition-level is the more serious, when a problem is serious enough that the provider doesn’t meet a whole condition of taking part in Medicare. Source: CMS, State Operations Manual.

What did inspectors find?

The last inspection on record was on Sep 24, 2025: a complaint inspection.

3 deficiencies cited in the last three years, 1 of them at condition level, the most serious.

1 deficiency at condition level, the more serious of CMS’s two levels

Source:

CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.

When those deficiencies happened

3 deficiencies in 1 month of the last 36. Last cited Sep 2025. Most serious: Condition-level. The last 3 years, to Oct 30, 2026.

3 deficiencies by month over the last 3 years. Each cell is one month.
JanFebMarAprMayJunJulAugSepOctNovDec
2023 NovDec
2024 JanFebMarAprMayJunJulAugSepOctNovDec
2025 JanFebMarAprMayJunJulAugSepOctNovDec
2026 JanFebMarAprMayJunJulAugSepOct

Hover or focus a month to read it.

No visit on record Visited, nothing cited A stronger orange is more serious, on its source’s own levels, read onto four bands: from the least serious it publishes to the most
Source:

Hearth Record drew this from the dates and levels in the source’s own records.

Each deficiency, as cited

Rule titles as CMS’s inspectors cite them, set in sentence case.

Source:

CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.

Sep 24, 2025: complaint inspection3 deficiencies
  • Cfc - Physical Environment

    “CFC-PHYSICAL ENVIRONMENT CFR(s): 494.60 This Condition is not met as evidenced by: 30377 Based on observation and interview, the facility staff failed to ensure the dialysis facility was maintained in a safe, functional, and comfortable treatment environment. This deficient practice has the likelihood of increasing the risk of injury and increasing the risk of infections to dialysis patients receiving treatment at the facility. Refer to tag V401”

    Rule V0400. Condition-level. From a complaint.

  • Mixing Systems - Permanent Record/Verification Testing

    The inspectors’ words, 450 words

    “MIXING SYSTEMS-PERM RECORD/VERIF TEST CFR(s): 494.40(a) 5.4.4.1 Mixing systems: perm record/verification testing In addition to container labeling, there should be permanent records of batches produced. These records should include the concentrate formula produced, the volume of the batch, the lot numbers of powdered concentrate packages, the manufacturer of the powdered concentrate, the date and time of mixing, any test results, the person performing the mixing, the person verifying mixing and test results, and the expiration date (if applicable). 6.4.1 Mixing systems Acid and bicarbonate concentrates may be tested by using conductivity or by using a hydrometer. Concentrates should not be used or transferred to holding tanks or distribution systems until all tests are completed. The test results and verification that they meet all applicable criteria should be recorded and signed by the individuals performing the tests. This Standard is not met as evidenced by: 30377 Based on facility log review and staff interviews, the facility failed to ensure that the Bicarbonate Concentrate System with Loop Log demonstrated complete documentation of required information to ensure and verify daily monitoring and weekly disinfection. Findings included: Review of Bicarbonate Concentrate System with Loop Log on 09/23/25 in the facility conference room for July 2025, August 2025 and September 2025 revealed the following: Review of July 2025 Bicarbonate Concentrate System with Loop Log revealed under the heading of Disinfectant Used, Presence Test, and Residual Test the area was BLANK for the following dates: 07/17/25 and 07/31/25 Review of July 2025 Bicarbonate Concentrate System with Loop Log revealed under the heading of RINSE the area was BLANK for the following dates: 07/09/25 and 07/31/25. Review of July 2025 Bicarbonate Concentrate System with Loop Log revealed under the heading of Decalcification / Initials the area was BLANK for the following dates: 07/09/25, 07/17/25, 07/18/25, and 07/31/25 Review of August 2025 Bicarbonate Concentrate System with Loop Log revealed under the heading of RINSE the area was BLANK for the following dates: 08/13/25, 08/15/25, 08/20/25, and 08/27/25 Review of August 2025 Bicarbonate Concentrate System with Loop Log revealed under the heading of Decalcification / Initials the area was BLANK for the following dates: 08/06/25, 08/13/25, 08/20/25, 08/22/25, and 08/27/25 Review of September 2025 Bicarbonate Concentrate System with Loop Log revealed under the heading of RINSE the area was BLANK for the following dates: 09/18/25 Review of September 2025 Bicarbonate Concentrate System with Loop Log revealed under the heading of Decalcification / Initials the area was BLANK for the following dates: 09/02/25 In an interview with Staff # 1 and # 3 on 09/23/2025 at 12:45 PM, after their own review confirmed the above findings. Staff # 1 stated she does not typically review the Bicarbonate Concentrate System Logs.”

    Rule V0229. Standard-level. From a complaint.

  • Pe - Safe, Functional, Comfortable Environment

    The inspectors’ words, 463 words

    “PE-SAFE/FUNCTIONAL/COMFORTABLE ENVIRONMENT CFR(s): 494.60 The dialysis facility must be designed, constructed, equipped, and maintained to provide dialysis patients, staff, and the public a safe, functional, and comfortable treatment environment. This Standard is not met as evidenced by: 30377 Based on observation and interview, the facility staff failed to ensure the dialysis facility was maintained in a safe, functional, and comfortable treatment environment. This deficient practice has the likelihood of increasing the risk of injury and increasing the risk of infections to dialysis patients receiving treatment at the facility. During a tour of the facility on 09/17/25 with (Staff #3) the following was noted: Treatment Area: Behind the lab refrigerator the wall was missing drywall causing the electrical outlet to dangle from the wall. The lab refrigerator was plugged into the dangling outlet. Mini Blinds covering the windows observed with dust built up and with damaged and missing blinds. Multiple cabinet walls behind the dialysis machine observed with significant paint peeling and damage. Multiple staff chairs with missing or worn away fabric Multiple dialysis machines in use had significant dust built up on the back panels of the machine, diasate filter housing, and on top of the diasafe filter cases. Multiple dialysis machines in use observed with significant paint peeling and cracking especially at the base of the machine. Multiple observations of blood pressure cuffs attached to the dialysis machine with excessive lent built up on the Velcro. Multiple observations of dialysis chair recliners with cracked and worn away fabric. Multiple observations of dried brown drips on the side of the dialysis chairs. Multiple observations of rust and grim built up on the metal aspect of the dialysis chairs. Biomed Office / Work area: Very disorganized with paperwork scattered throughout the area. Desk Chair with excessive amount of fabric worn away. Storage Area: Disorganized / Dusty with clean supplies not separated from used supplies such as Christmas supplies and discarded equipment. The corners and area around the back door were observed with excessive amounts of grim built up Water Room and adjacent area: The area was dusty, and the excessive amount of spilled acid build up remained under crates that held the acid tanks and boxed supplies. The acid build up was several inches thick. The Top of the Bicarb Tank observed with excessive amount of dust built up The pipes to the acid tanks observed with excessive amounts of acid build up. Several Ceiling tiles observed with large brown stains. The (Staff #3) accompanied the surveyor on the tour of the facility and all findings were acknowledged and confirmed. Interview with Staff # 2 on 09/23/25 at 10:30AM stated he was aware of the above findings but did not have any documented evidence that the facility was addressing any of the above issues.”

    Rule V0401. Standard-level. From a complaint.

The one inspection in the last three years
Inspections on record
DateVisitWhat the record says
Sep 24, 2025Complaint inspection3 deficiencies cited

Is it certified?

  • Medicare-certified dialysis facility, certified or last recertified on May 27, 2003.
  • Run for profit.
  • Cited at in the last three years: it didn’t meet a whole condition of Medicare’s rules for dialysis facilities.
  • Chain: American Renal Associates.
Source:

CMS, Dialysis Facility - Listing by Facility. Released Jul 15, 2026. Updated quarterly.

CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.

Has it been penalized?

  • CMS doesn’t publish fines or other penalties for dialysis facilities.
  • 3 deficiencies cited in the last three years came from inspections that included a complaint investigation.
Source:

CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.

What does it offer?

  • Offers in-center hemodialysis.
  • Doesn’t offer peritoneal dialysis, home hemodialysis training and a shift starting at 5 p.m. or later.
  • 24 dialysis stations.
  • CMS doesn’t publish staffing levels for dialysis facilities.
  • In CMS’s survey, patients rate its staff 5 of 5.
Source:

CMS, Dialysis Facility - Listing by Facility and Patient survey (ICH CAHPS) - Facility. Released Jul 15, 2026. Updated quarterly.

Who owns it?

  • Part of the American Renal Associates chain, as CMS lists it.
  • CMS publishes no owners file for dialysis facilities, so no other owner is named.
Source:

CMS, Dialysis Facility - Listing by Facility. Released Jul 15, 2026. Updated quarterly.

How do patients fare?

  • CMS rates it 3 of 5 stars (Jan 1, 2021 to Dec 31, 2024).
  • Compared by CMS with what it expects for the facility’s patients: patient survival, as expected; hospital admissions, as expected; readmissions to hospital, as expected; emergency department visits, as expected; emergency department visits within 30 days of a hospital stay, as expected; bloodstream infections, as expected; patients dialysing through a fistula, as expected; patients put on a kidney transplant waitlist in their first year of dialysis, as expected; patients on a kidney transplant waitlist, as expected.
  • Patients rate it 5 of 5 in CMS’s survey of in-center hemodialysis patients (33 interviews, Oct 18, 2024 to Jul 11, 2025): 85% rated the facility 9 or 10 out of 10.
Source:

CMS, Dialysis Facility - Listing by Facility and Patient survey (ICH CAHPS) - Facility. Released Jul 15, 2026. Updated quarterly.

Ratings and measures, as published
MeasureRating
Star ratingCMS’s star rating for dialysis facilities, 1 to 53 of 5
Patient survey ratingCMS star rating from its survey of the facility’s in-center hemodialysis patients (ICH CAHPS), 1 to 55 of 5

How does it compare nearby?

  • Of the 68 dialysis facilities CMS lists in Dallas County, 64 have a star rating from CMS: 2 rated 5 of 5, 7 rated 4 of 5, 31 rated 3 of 5, 20 rated 2 of 5, 4 rated 1 of 5.
  • CMS rates this one 3 of 5.
Source:

CMS, Dialysis Facility - Listing by Facility. Released Jul 15, 2026. Updated quarterly.

What the record doesn’t say

  • CMS doesn’t publish fines or other penalties for dialysis facilities, so none are shown.
  • Only complaints that led to a citation appear; complaints that didn’t aren’t published.
  • QCOR says it has no dialysis inspection reports after February 19, 2026, while it moves to a new system: a later inspection is not shown yet.
  • CMS doesn’t publish staffing levels for dialysis facilities.
  • CMS publishes no owners file for dialysis facilities: the chain it lists is the only owner named.

Sources

If you believe something here is wrong, a correction starts with the agency whose record this copies: CMS. CMS’s own record is on Care Compare. If Hearth Record copied something wrongly, it will fix it and log the correction publicly, with its date: how corrections work.

Source:

This copy of the record was made on Oct 30, 2026.

From the facility

The public record above comes first. Anything the facility adds will appear here, below it, and say who wrote it.

Replies

None. Replies aren’t open yet. When they open, the facility will be able to answer any finding for free, and the reply will show beside that finding, unedited and dated.

Paid listing

None. Paid listings aren’t open yet. When they open, anything paid for will say “Paid by the facility”, and paying will never change a finding, a rating or the order of results.

How to read a record

Four things every record does, shown on an example record made up for this guide.

An example record, made up for this guide

An example nursing home

Made up for this guide: no real place is shown

Not fully inspected in over two years (CMS flag)

11 health citations at the latest inspection cycle

The state average is 14.3.

Source:

CMS, State and US Averages and Health Deficiencies. Released Oct 8, 2026. Updated monthly.

From the homeNone yet. Replies and paid listings aren’t open, and when they open they will sit here, below the record.

1 of 4

Every fact names its source.

Who published it, when, and how often it changes sit beside each fact, with a link to the agency’s own file.

Sign in