Davita Conroe Dialysis

A dialysis facility in Conroe, Texas 77304

233 Interstate 45 North, Conroe, Texas 77304. (936) 760-2240.

CMS’s own record, on Care Compare

Watch and the shortlist are kept with a free account, on every device. Your watch list. CMS’s own record is on Care Compare.

The short answer

Record last released by CMS on Oct 28, 2026.

The last 24 months 5 deficiencies in 1 month of the last 36. Last cited Jul 2025. Most serious: Standard-level. Every month

Each figure’s source sits beside it, in its section below.

What these words mean3
Star ratings
CMS rates some kinds of place from 1 to 5 stars, more stars meaning better on CMS’s own measures for that kind: for a nursing home, its health inspections, staffing and quality measures. A rating is CMS’s summary of those measures; it doesn’t promise good care. Source: CMS, Care Compare and the Five-Star Quality Rating System.
Inspection (survey)
A visit by state inspectors, often unannounced, who check a place against the rules it must meet. For nursing homes and other places Medicare pays, CMS calls these visits surveys: a standard survey of a nursing home comes at least every 15 months, and a complaint survey whenever a complaint calls for one. Source: CMS; 42 CFR 488.308.
Deficiency, citation, violation
What inspectors write up when a place didn’t meet a rule: the rule, what they saw, and when. CMS calls it a deficiency; states may say citation or violation. It is the inspectors’ finding, not a court’s, and the place is usually asked for a plan to correct it. Source: CMS, statement of deficiencies (Form CMS-2567); each state’s licensing agency.

What did inspectors find?

The last inspection on record was on Jul 15, 2025: a standard inspection.

5 deficiencies cited in the last three years.

Source:

CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.

When those deficiencies happened

5 deficiencies in 1 month of the last 36. Last cited Jul 2025. Most serious: Standard-level. The last 3 years, to Oct 30, 2026.

5 deficiencies by month over the last 3 years. Each cell is one month.
JanFebMarAprMayJunJulAugSepOctNovDec
2023 NovDec
2024 JanFebMarAprMayJunJulAugSepOctNovDec
2025 JanFebMarAprMayJunJulAugSepOctNovDec
2026 JanFebMarAprMayJunJulAugSepOct

Hover or focus a month to read it.

No visit on record Visited, nothing cited A stronger orange is more serious, on its source’s own levels, read onto four bands: from the least serious it publishes to the most
Source:

Hearth Record drew this from the dates and levels in the source’s own records.

Each deficiency, as cited

Rule titles as CMS’s inspectors cite them, set in sentence case.

Source:

CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.

Jul 15, 2025: standard inspection5 deficiencies
  • Compliance With Fed/State/Local Laws

    The inspectors’ words, 367 words

    “COMPLIANCE WITH FED/STATE/LOCAL LAWS CFR(s): 494.20 The facility and its staff must operate and furnish services in compliance with applicable Federal, State, and local laws and regulations pertaining to licensure and any other relevant health and safety requirements. This Standard is not met as evidenced by: 43999 Based on review of documentation and interview, the facility staff did not comply Texas ESRD Rules and Regulations. The Charge nurse was assigned direct patient care and the patient was not seen by the physician once every two weeks. Findings: During review of patient/staff assignments for patient care on 4/15/25 and 4/16/25 it was found there were two nurses assigned to provide patient care with no designated CN (charge nurse). In an interview with the nurse (staff # 1) on 4/15/25 during observation of the treatment floor it was shared all the nurses provide direct patient care. The two RN’s provide patient care to all patients that have a CVC (Central Venous Catheter) administer medications, perform patient assessments, supervise patient care and other CN (charge nurse) responsibilities. The two RNs share direct patient care and there is no other RN scheduled as the CN who is not assigned direct patient care. Additional review of the facility’s January - March 2025 staff schedule and patient/staff assignments revealed two RNs are scheduled with no additional CN scheduled. Review of patient provider progress notes for the months of January 2025 through March 2025, revealed the following: - Patient # 3 - One provider note in March 2025. - Patient # 8 - No provider note in February or March 2025. - Patient # 13 - One provider note in January and February 2025, no provider note in March 2025. - Patient # 14 - No provider note in January 2025, and one provider note in March 2025. - Patient # 15 - One provider note in January, February and March 2025. - Patient # 16 - One provider note in January and March 2025, no provider note in February 2025. - Patient # 17 - One provider note in January 2025, no provider note in February and March 2025. In an interview on 04/15/25, Staff #1 & #2 the above findings were confirmed.”

    Rule V0101. Standard-level.

  • Ic - Clean, Disinfect Surfaces & Equipment/Written Protocols

    The inspectors’ words, 464 words

    “IC-DISINFECT SURFACES/EQUIP/WRITTEN PROTOCOL CFR(s): 494.30(a)(4)(ii) [The facility must demonstrate that it follows standard infection control precautions by implementing- (4) And maintaining procedures, in accordance with applicable State and local laws and accepted public health procedures, for the-] (ii) Cleaning and disinfection of contaminated surfaces, medical devices, and equipment. This Standard is not met as evidenced by: 43999 Based on observation and review the facility staff failed to follow standard infection control precautions while performing direct patient care. Findings: Review of Procedure: 1-04-02B, titled CENTRAL VENOUS CATHETER (CVC) WITH CLEARGUARD HD ANTIMICROBIAL END CAPS PROCEDURE, stated in part: “Perform a 15 second hub scrub of the CVC during the process of connecting or disconnecting from the blood lines, including line reversal, or if the patient is disconnected during treatment for any reason ...” During the facility tour on 4/15/25, observations revealed: -At 12:02 p.m., Staff #9 only performed a 2 to 3 second scrub of the CVC hubs while disconnecting the blood lines for patient #2. Review of Procedure: 1-21-02, titled OPERATION OF PORTABLE MYRON L CONDUCTIVITY METER (D-1), stated in part: “The exterior of D1 meter should be cleaned with 1:100 bleach solution after collecting a sample from another dialysis delivery system to prevention [sic] cross contamination ... ...The outside of the D-1 meter must be disinfected after use prior to returning the meter to the storage location.” During the facility tour on 4/15/25, observations revealed: -Staff #10 demonstrated the use of the shared Myron L meter - staff takes the meter to the hemodialysis machine (HD) to perform the test - then takes the Myron L meter back to the clean area without disinfecting it. Review of Procedure: 1-05-01, titled INFECTION CONTROL FOR DIALYSIS FACILITIES, stated in part: “HAND HYGIENE 1. All teammates ...will perform hand hygiene ... b. prior to gloving and immediately after removal of gloves ... d. after patient and dialysis delivery system contact ... g. before touching clean areas such as supplies, supply cart and chairside keyboard/mouse.” During the facility tour on 4/15/25, observations revealed: - 4 of 4 staff members (#9, 10, 11, and 12) failed to perform hand hygiene before donning gloves. - Staff #10 failed to perform hand hygiene after removing gloves and before documenting on the computer. - At 12:00 p.m., Staff #9, RN, failed to remove their gloves used while performing patient care then went to a clean area to retrieve a catheter removal kit. - At 12:02 p.m., while performing catheter care, Staff #9 removed their gloves and failed to perform hand hygiene before donning a new pair of gloves. Staff #1 witnessed the above and told staff #9 to perform hand hygiene before donning a new pair of gloves. In an interview with Staff #1 on 4/16/25, the above findings were confirmed.”

    Rule V0122. Standard-level.

  • Pe - Safe, Functional, Comfortable Environment

    The inspectors’ words, 134 words

    “PE-SAFE/FUNCTIONAL/COMFORTABLE ENVIRONMENT CFR(s): 494.60 The dialysis facility must be designed, constructed, equipped, and maintained to provide dialysis patients, staff, and the public a safe, functional, and comfortable treatment environment. This Standard is not met as evidenced by: 43999 Based on observation and interview, the facility staff failed to maintain the floors in the patient treatment area to provide dialysis patients, staff, and the public a safe, functional, and comfortable treatment environment. Findings : During observation of the facility treatment area on 4/15/25, the floor laminate had areas that were worn and cracked, preventing effective cleaning of the areas. In an interview 4/16/25 with staff #17, the above findings were confirmed. Staff #17 shared the work orders had been submitted, approved and closed with no evidence the floor laminate in the treatment area was repaired.”

    Rule V0401. Standard-level.

  • Outcome Not Achieved - Adjust Poc

    The inspectors’ words, 880 words

    “POC-OUTCOME NOT ACHIEVED-ADJUST POC CFR(s): 494.90(b)(3) If the expected outcome is not achieved, the interdisciplinary team must adjust the patient’s plan of care to achieve the specified goals. When a patient is unable to achieve the desired outcomes, the team must- (i) Adjust the plan of care to reflect the patient’s current condition; (ii) Document in the record the reasons why the patient was unable to achieve the goals; and (iii) Implement plan of care changes to address the issues identified in paragraph (b)(3)(ii) of this section. This Standard is not met as evidenced by: 43999 Based on facility documentation, observation and staff interviews, the facility Interdisciplinary team failed to adjust the patients’ plan of care to achieve specific goals for 2 of 2 patients (#2 and #4). Findings: A review of facility policies revealed: Review of Incenter Hemodialysis Policies & Procedures DaVita Inc., Policy 1-03-08, titled “PRE-INTRA-POST TREATMENT DATA COLLECTION, MONITORING AND NURSING ASSESSMENT”, which states in part: “INTRADIALYTIC DATA COLLECTION/ASSESSMENT 10. If the dialysis prescription is not being met (including dialysis flow rate or change to /inability to obtain prescribed blood flow rate) the reason will be documented and the licensed nurse informed. 11. Abnormal findings or findings outside of any patient specific physician ordered parameters will be reported to the licensed nurse immediately .... 12. The licensed nurse notifies the physician (or NPP if applicable) as needed of changes in patient status. 13. All findings, interventions and patient response will be documented in the patient’s medical record .... ABNORMAL FINDINGS Within each category, definitions may be adjusted by a patient specific physician order. In addition, the teammate who is observing or collecting information should report to the licensed nurse whenever there is concern for the patient’s condition or the potential safety of initiating dialysis, even in the absence of specific abnormal findings. ...” Observations revealed: During the facility tour on the morning of 4/15/25, observations revealed a Blood Flow Rate (BFR) set at 280 mL/min on the Hemodialysis (HD) machine for patient #2. The treatment overview sheet revealed a prescribed BFR of 350 mL/min. Staff #1 confirmed these findings and stated they had been having issues with patient #2’s central venous catheter (CVC) access, and staff typically had to decrease the BFR. Staff #1 also confirmed there was no documentation showing the physician was aware of any ongoing issues with patient #2’s CVC or had ordered any interventions to improve the BFR. Review of treatment sheets for patient #2 revealed the following: 04/15/25: 09:02 - BFR 300 by staff #12, no RN assessment/notification. 09:32 - BFR 280 mL/min by staff #12, no RN assessment/notification. 04/10/25: 08:30 - “BFR set to 300 due to poor outflow on CVC” by staff #9. 09:32 “BFR set to 210 due to AP bottoming out” by staff #9. A review of the “Comprehensive Assessment Report” from 01/28/25 for patient #2 revealed a prescribed BFR of 350 and an average BFR below 350 mL/min on 13 of 13 dates: 01/28/25 - 214 01/25/25 - 211 01/23/25 - 274 01/20/25 - 242 01/18/25 - 304 01/16/25 - 267 01/14/25 - 245 01/11/25 - 291 01/09/25 - 333 01/07/25 - 284 01/04/25 - 250 01/02/25 - 332 12/31/24 - 284 During the facility tour on 04/15/25, at 12:02 pm, patient #4 was observed to have a heart rate (HR) of 57 and a blood pressure of 155/48. Staff #1 stated these vital signs (v/s) were “normal” for this patient but could not provide documentation that the physician was aware and had changed patient #4’s v/s parameters. Staff #1 could not confirm that other staff would know these were “normal” v/s for patient #4. Review of treatment sheets for patient #4 revealed the following: 04/08/25: 10:14 - BP 126/42, HR 55 by staff #1 10:34 - BP 140/36, HR 52 by staff #12 11:04 - BP 106/29, HR 54 by staff #12 11:05 - BP 107/38, HR 54 by staff #12 11:34 - BP 110/21, HR 53 by staff #10 12:04 - BP 133/35, HR 52 by staff #9 12.34 - BP 140/41, HR 48 by staff #9 13:04 - BP 128/36, HR 52 by staff #9 13:16 - BP 119/22, HR 52 by staff #9 04/15/25: 10:15 - BP 177/47, HR 58 by staff #1 10:31 - BP 159/42, HR 57 by staff #11 11:01 - BP 179/42, HR 56 by staff #12 11:03 - BP 161/44, HR 56 by staff #12 11:31 - BP 172/43, HR 55 by staff #12 12:02 - BP 155/48, HR 57 by staff #12 12.31 - BP 151/124, HR 59 by staff #12 13:01 - BP 156/43, HR 54 by staff #12 13:16 - BP 165/42, HR 53 by staff #9 A review of the “Comprehensive Assessment Report” from 04/08/25 for patient #4 revealed: - A SBP > 180 on 3 out of 8 treatment dates: 04/05/25 - 190/51 04/01/25 - 188/47 03/18/25 - 187/40 - Under the heading “Fluid/BP”, for “Blood Pressure Screening”, and in response to “Is pre-dialysis blood pressure elevated?”, staff #1 documented “No”. - A review of the “Fluid and BP Management Report” from 04/15/25 for patient #4 revealed a SBP > 180 on 2 out of 3 treatment dates: 04/15/25 - 184/55 04/05/25 - 190/51 On 4/16/25 staff #1 & 2 acknowledged the above.”

    Rule V0559. Standard-level.

  • Md Resp - Ensure All Adhere To P&P

    The inspectors’ words, 975 words

    “MD RESP-ENSURE ALL ADHERE TO P&P CFR(s): 494.150(c)(2)(i) The medical director must- (2) Ensure that- (i) All policies and procedures relative to patient admissions, patient care, infection control, and safety are adhered to by all individuals who treat patients in the facility, including attending physicians and nonphysician providers; This Standard is not met as evidenced by: 43999 Based on record reviews and interviews, the medical director did not ensure all policies and procedures relative to patient care are adhered to by facility staff. Findings: Facility Procedure titled, “12-13-10F - TITLE: OPERATION OF PORTABLE MYRON L CONDUCTIVITY METER (D-1)” states in part, “11. When finished with the D-1 meter, RINSE thoroughly with dialysis quality water.” On 4/16/25, staff (#10 & 11) were observed using the Myron L meter to check conductivity of the machine and did not rinse with RO (reverse osmosis) water between machine testing per procedure. The staff member acknowledged they did not follow the procedure when using the Myron-L meter. Facility Procedure titled “1-03-08F- TITLE: TREATMENT INITIATION UTILIZING FRESENIUS 2008 SERIES DIALYSIS DELIVERY SYSTEMS WITH ALL SINGLE USE DIALYZER TYPES AND STREAMLINE OR COMBISET OR NIPRO BLOOD LINES” states in part, “7. Establish access per procedure and administer heparin loading dose per procedure, as applicable. Wait a minimum of three (3) to five(5) minutes following administration of heparin loading dose prior to actual initiation of treatment.” During observation 4/16/25 on the treatment floor, Staff #9 & 14 did not wait 3-5 minutes following administration of heparin to initiation of treatment. Both staff confirmed they soul wait 3-5 minutes after heparinization to initiate treatment. Review of Incenter Hemodialysis Policies & Procedures titled, “Policy 1-03-08, titled “PRE-INTRA-POST TREATMENT DATA COLLECTION, MONITORING AND NURSING ASSESSMENT”, which states in part: “INTRADIALYTIC DATA COLLECTION/ASSESSMENT ...11. Abnormal findings or findings outside of any patient specific physician ordered parameters will be reported to the licensed nurse immediately .... 12. The licensed nurse notifies the physician (or NPP if applicable) as needed of changes in patient status. 13. All findings, interventions and patient response will be documented in the patient’s medical record .... ABNORMAL FINDINGS Within each category, definitions may be adjusted by a patient specific physician order. In addition, the teammate who is observing or collecting information should report to the licensed nurse whenever there is concern for the patient’s condition or the potential safety of initiating dialysis, even in the absence of specific abnormal findings. ... Members of the patient care team should report ANY changes in patient conditions or concerns of patient well-being immediately to the licensed nurse at any time .... Blood pressure (BP): Pre-dialysis: o Systolic greater than 180 mm Hg or less than 90 mm Hg o Diastolic greater than or equal to 100 mm Hg Blood Pressure-Intradialytic: o Difference of 20 mm Hg increase or decrease from patient’s last intradialytic treatment BP reading .... Heart or Pulse Rate Pre/Intra/Post: o Less than 60 beats per minute or greater than 100 beats per minute and/or an irregular heart beat ....” Review of treatment sheets for patient #2 revealed the following: 04/10/25: 08:32 BP 146/111 by staff #10, no RN assessment/notification of diastolic blood pressure (DBP) greater than (>) 100. 09:02 BP 150/108 by staff #10, no RN assessment/notification of DBP >100. 09:34 BP 147/102 by staff #14, no RN assessment/notification of DBP >100. 10:02 BP 147/111 by staff #14, no RN assessment/notification of DBP >100. 10:32 BP 130/106 by staff #10, no RN assessment/notification of DBP >100. 11:02 - V/S documented by staff #10 within defined limits (WDL). 11:32 BP 140/109 by staff #10, no RN assessment/notification of DBP >100. 04/15/25: 08:30 - BP 177/114 by staff #9, no RN assessment/notification of DBP >100 09:02 - BP 166/115 by staff #12, no RN assessment/notification of DBP >100. 09:32 - BP 166/121 by staff #12, no RN assessment/notification of DBP >100. 10:02 - BP 156/117 by staff #12, no RN assessment/notification of DBP >100. 10:32 - BP 153/112 by staff #12, no RN assessment/notification of DBP >100. 11:02 - BP 163/106 by staff #12, no RN assessment/notification of DBP >100. 11:32 - BP 135/102 by staff #12, no RN assessment/notification of DBP >100 or decrease of 28 mm Hg from patient’s previous systolic (S) BP measurement. 12:00 - BP 137/101 by staff #12, no RN assessment/notification of DBP >100. During the same facility tour on 04/15/25, at 12:02 pm, patient #4 was observed to have a heart rate (HR) of 57 and a BP of 155/48. Staff #1 stated these vital signs (v/s) were “normal” for this patient but could not provide documentation that the physician was aware and had changed patient #4’s v/s parameters. Staff #1 could not confirm that other staff would know these were “normal” v/s for patient #4. Review of treatment sheets for patient #4 revealed the following: 04/08/25: 10:14 - BP 126/42, HR 55 by staff #1 10:34 - BP 140/36, HR 52 by staff #12 11:04 - BP 106/29, HR 54 by staff #12 11:05 - BP 107/38, HR 54 by staff #12 11:34 - BP 110/21, HR 53 by staff #10 12:04 - BP 133/35, HR 52 by staff #9 12.34 - BP 140/41, HR 48 by staff #9 13:04 - BP 128/36, HR 52 by staff #9 13:16 - BP 119/22, HR 52 by staff #9 04/15/25: 10:15 - BP 177/47, HR 58 by staff #1 10:31 - BP 159/42, HR 57 by staff #11 11:01 - BP 179/42, HR 56 by staff #12 11:03 - BP 161/44, HR 56 by staff #12 11:31 - BP 172/43, HR 55 by staff #12 12:02 - BP 155/48, HR 57 by staff #12 12.31 - BP 151/124, HR 59 by staff #12 13:01 - BP 156/43, HR 54 by staff #12 13:16 - BP 165/42, HR 53 by staff #9 Staff #1 confirmed the above findings in an interview 4/16/25.”

    Rule V0715. Standard-level.

All 2 inspections in the last three years
Inspections on record
DateVisitWhat the record says
Jul 15, 2025Standard inspection5 deficiencies cited
Apr 17, 2025Complaint inspectionNo deficiencies cited

Is it certified?

  • Medicare-certified dialysis facility, certified or last recertified on May 9, 1995.
  • Run for profit.
  • No deficiency on record in the last three years.
  • Chain: DaVita.
Source:

CMS, Dialysis Facility - Listing by Facility. Released Jul 15, 2026. Updated quarterly.

CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.

Has it been penalized?

  • CMS doesn’t publish fines or other penalties for dialysis facilities.
  • None of the deficiencies cited in the last three years came from an inspection that included a complaint investigation.
Source:

CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.

What does it offer?

  • Offers in-center hemodialysis.
  • Doesn’t offer peritoneal dialysis, home hemodialysis training and a shift starting at 5 p.m. or later.
  • 16 dialysis stations.
  • CMS doesn’t publish staffing levels for dialysis facilities.
Source:

CMS, Dialysis Facility - Listing by Facility and Patient survey (ICH CAHPS) - Facility. Released Jul 15, 2026. Updated quarterly.

Who owns it?

  • Part of the DaVita chain, as CMS lists it.
  • CMS publishes no owners file for dialysis facilities, so no other owner is named.
Source:

CMS, Dialysis Facility - Listing by Facility. Released Jul 15, 2026. Updated quarterly.

How do patients fare?

  • CMS rates it 1 of 5 stars (Jan 1, 2021 to Dec 31, 2024).
  • Compared by CMS with what it expects for the facility’s patients: patient survival, as expected; hospital admissions, worse than expected; readmissions to hospital, worse than expected; blood transfusions, as expected; emergency department visits, as expected; emergency department visits within 30 days of a hospital stay, as expected; bloodstream infections, as expected; patients dialysing through a fistula, as expected; patients put on a kidney transplant waitlist in their first year of dialysis, as expected; patients on a kidney transplant waitlist, as expected.
  • CMS gives no : “Too few completed survey responses to report.”
Source:

CMS, Dialysis Facility - Listing by Facility and Patient survey (ICH CAHPS) - Facility. Released Jul 15, 2026. Updated quarterly.

Ratings and measures, as published
MeasureRating
Star ratingCMS’s star rating for dialysis facilities, 1 to 51 of 5
Patient survey ratingCMS star rating from its survey of the facility’s in-center hemodialysis patients (ICH CAHPS), 1 to 5Not rated

How does it compare nearby?

  • Of the 14 dialysis facilities CMS lists in Montgomery County, 13 have a star rating from CMS: 1 rated 4 of 5, 5 rated 3 of 5, 6 rated 2 of 5, 1 rated 1 of 5.
  • CMS rates this one 1 of 5.
Source:

CMS, Dialysis Facility - Listing by Facility. Released Jul 15, 2026. Updated quarterly.

What the record doesn’t say

  • CMS doesn’t publish fines or other penalties for dialysis facilities, so none are shown.
  • Only complaints that led to a citation appear; complaints that didn’t aren’t published.
  • QCOR says it has no dialysis inspection reports after February 19, 2026, while it moves to a new system: a later inspection is not shown yet.
  • CMS doesn’t publish staffing levels for dialysis facilities.
  • CMS publishes no owners file for dialysis facilities: the chain it lists is the only owner named.

Sources

If you believe something here is wrong, a correction starts with the agency whose record this copies: CMS. CMS’s own record is on Care Compare. If Hearth Record copied something wrongly, it will fix it and log the correction publicly, with its date: how corrections work.

Source:

This copy of the record was made on Oct 30, 2026.

From the facility

The public record above comes first. Anything the facility adds will appear here, below it, and say who wrote it.

Replies

None. Replies aren’t open yet. When they open, the facility will be able to answer any finding for free, and the reply will show beside that finding, unedited and dated.

Paid listing

None. Paid listings aren’t open yet. When they open, anything paid for will say “Paid by the facility”, and paying will never change a finding, a rating or the order of results.

How to read a record

Four things every record does, shown on an example record made up for this guide.

An example record, made up for this guide

An example nursing home

Made up for this guide: no real place is shown

Not fully inspected in over two years (CMS flag)

11 health citations at the latest inspection cycle

The state average is 14.3.

Source:

CMS, State and US Averages and Health Deficiencies. Released Oct 8, 2026. Updated monthly.