Hearth Record

Davita North Houston Dialysis Center

A dialysis facility in Houston, Texas 77022

8621 Fulton St, Houston, Texas 77022. (713) 699-3748.

CMS’s own record, on Care Compare

Watch and the shortlist are kept with a free account, on every device. Your watch list. CMS’s own record is on Care Compare.

The short answer

Record last released by CMS on Oct 28, 2026.

The last 24 months 6 deficiencies in 1 month of the last 36. Last cited Feb 2025. Most serious: Condition-level. Every month

Each figure’s source sits beside it, in its section below.

What these words mean4
Star ratings
CMS rates some kinds of place from 1 to 5 stars, more stars meaning better on CMS’s own measures for that kind: for a nursing home, its health inspections, staffing and quality measures. A rating is CMS’s summary of those measures; it doesn’t promise good care. Source: CMS, Care Compare and the Five-Star Quality Rating System.
Inspection (survey)
A visit by state inspectors, often unannounced, who check a place against the rules it must meet. For nursing homes and other places Medicare pays, CMS calls these visits surveys: a standard survey of a nursing home comes at least every 15 months, and a complaint survey whenever a complaint calls for one. Source: CMS; 42 CFR 488.308.
Deficiency, citation, violation
What inspectors write up when a place didn’t meet a rule: the rule, what they saw, and when. CMS calls it a deficiency; states may say citation or violation. It is the inspectors’ finding, not a court’s, and the place is usually asked for a plan to correct it. Source: CMS, statement of deficiencies (Form CMS-2567); each state’s licensing agency.
Condition-level deficiency
For hospices, home health agencies, hospitals and dialysis facilities, CMS writes deficiencies at two levels. Standard is the usual one; condition-level is the more serious, when a problem is serious enough that the provider doesn’t meet a whole condition of taking part in Medicare. Source: CMS, State Operations Manual.

What did inspectors find?

The last inspection on record was on Mar 26, 2025: a complaint inspection.

6 deficiencies cited in the last three years, 1 of them at condition level, the most serious.

1 deficiency at condition level, the more serious of CMS’s two levels

Source:

CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.

When those deficiencies happened

6 deficiencies in 1 month of the last 36. Last cited Feb 2025. Most serious: Condition-level. The last 3 years, to Oct 30, 2026.

6 deficiencies by month over the last 3 years. Each cell is one month.
JanFebMarAprMayJunJulAugSepOctNovDec
2023 NovDec
2024 JanFebMarAprMayJunJulAugSepOctNovDec
2025 JanFebMarAprMayJunJulAugSepOctNovDec
2026 JanFebMarAprMayJunJulAugSepOct

Hover or focus a month to read it.

No visit on record Visited, nothing cited A stronger orange is more serious, on its source’s own levels, read onto four bands: from the least serious it publishes to the most
Source:

Hearth Record drew this from the dates and levels in the source’s own records.

Each deficiency, as cited

Rule titles as CMS’s inspectors cite them, set in sentence case.

Source:

CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.

Feb 19, 2025: standard inspection6 deficiencies
  • Cfc - Infection Control

    The inspectors’ words, 422 words

    “CFC-INFECTION CONTROL CFR(s): 494.30 This Condition is not met as evidenced by: 48020 Based on observation and interview, the facility’s staff assigned duties in the Water Room failed to verify that the acid mixer, acid storage tank, water softener, and water room is clean B) the facility’s direct care staff failed to clean debris underneath the chase cabinets behind the hemodialysis machines C) the facility failed to maintain a sanitary environment as evidenced by dead insects in the light covers throughout the facility D) the facility failed to maintain a safe environment as evidenced by expired supplies co-mingled with supplies in use in the facility for care and services of patients E) the facility failed to maintain a sanitary environment as evidenced by rusts on the lower legs and casters of 8 rolling stools Cross reference V 111 Based on observation, interview and record review, the facility’s direct care staff: failed to perform hand hygiene after removal of contaminated gloves per the facility’s policy in 4 of 6 staff observed: Patient Care Technician (F), (D), (E), (C) B) failed to change gloves when going from a “dirty” area or task to a “clean” area or task per the facility’s policy in 2 of 6 staff observed: Patient Care Technician (F), (E) Cross reference V 113 Based on observation, interview and record review, the facility’s direct care staff: failed to prevent cross contamination by storing several chairside computer carts in between hemodialysis machines in use (in the splash zone) B) failed to prevent cross contamination by storing a contaminated face shield on the clean computer cart keyboard: Patient Care Technician (C) Cross reference V 117 Based on observation, interview and record review, the facility’s direct care staff: failed to clean and disinfect stethoscopes, intravenous poles and rungs, hemodialysis machine, dialysate lines and chase counter tops behind the dialysis stations according to the facility’s policy in 4 of 6 staff observed: Patient Care Technician (F), (E), (O), (P) B) failed to prevent cross contamination by wiping the wall boxes and using the same towel to wipe the chase cabinet and dialysate lines in the back of the hemodialysis machine in 3 of 6 staff observed: Patient Care Technician (F), (O), (P) C) failed to ensure that infection control was maintained as evidenced by hemodialysis chairs with tape and tape residue in 13 of 24 chairs. D) failed to ensure that infection control was maintained as evidenced by tears in the vinyl of the hemodialysis chairs in 2 of 24 chairs. Cross reference V 122”

    Rule V0110. Condition-level.

  • Ic - Sanitary Environment

    The inspectors’ words, 621 words

    “IC-SANITARY ENVIRONMENT CFR(s): 494.30 The dialysis facility must provide and monitor a sanitary environment to minimize the transmission of infectious agents within and between the unit and any adjacent hospital or other public areas. This Standard is not met as evidenced by: 48020 Based on observation and interview: the facility’s staff assigned duties in the Water Room failed to verify that the acid mixer, acid storage tank, water softener, and water room is clean B) the facility’s direct care staff failed to clean debris underneath the chase cabinets behind the hemodialysis machines C) the facility failed to maintain a sanitary environment as evidenced by dead pest in the light covers throughout the facility D) the facility failed to maintain a safe environment as evidenced by expired supplies co-mingled with supplies in use in the facility for care and services of patients E) failed to maintain a sanitary environment as evidenced by rusts on the lower legs and casters of 8 rolling stools Findings: Water Room: Observation of the water room on 02/18/2025 at 6:55 a.m. revealed the following: “ Debris on the floor- cap top, strip of paper, small pieces of cardboard box and tape that was removed from a cardboard box of acid that was stored in the water room “ Crystallized build up on the acid storage tank hose clamp and a 1-inch mound of crystallized build up on the floor underneath it “ 1-inch mound of crystallized acid build up on the floor underneath the acid storage tank hose connector “ Acid residue on the floor underneath the acid mixer and storage tank “ Rust on the acid mixer metal holder and brown residue on from the rust dripped down the back of the acid mixer “ Black residue on the floor behind the acid mixer “ Brown residue dripped down the front of the water softener Interview with Biomedical Technician (M) at 9:28 a.m. revealed that he cleans the water room once a month and the staff assigned to water room duties should keep it clean as well. Treatment Area: Observation of the treatment area on 02/18/2025 at 7:24 a.m. revealed debris on the floor underneath the chase cabinet (gauze, dialyzer endcaps) between stations #s 2-3 and 7-8. Interview during walkthrough with Charge Nurse (A) at 8:00 a.m. confirmed the findings. Dead pests in light covers: Observation of the facility on 02/19/2025 starting at 8:48 a.m. revealed dead pests in the lights covers in the conference room, both teammate restrooms, the break room, and the offices of the social worker and the administrative assistant. Interview during the walkthrough with the Manager of Clinical Safety (N) at 4:36 p.m. confirmed the findings. Expired supplies: Observation on 02/19/2024 at 11:10 AM to 13:00 PM of the patient treatment area along with the Manager of Clinical Services, Staff ID #N the following was identified: 20 - packages of Chlora Prep Single Swab Sticks , Lot # 2257432, Expiration Date 08/2024. Nipro 14-gauge Fistula Needles: 1 - Lot #14C18, Expiration date 02/2019. 1 - Lot #18H23B, Expiration date 07/31/2021. 1 - Lot #17619A, Expiration date 06/30/2022. 18 - Lot #17H29C, Expiration date 07/31/2022. 7 - Lot #18H23B, Expiration date 08/31/2023. 1 - Lot #18K20B, Expiration date 10/31/2023. 14 - Lot #18I15B, Expiration date 11/30/2024. Interview with Staff ID #N on 02/19/2025 at 12:45 PM confirmed the above expired supplies should not have been available for use and were past their expiration date. Rusted stools: Subsequent observation revealed: 8 - rolling stools were identified to have visible rust on the lower leg segments and the wheel casters. Interview with Staff ID #N on 02/19/2025 at 12:45 PM confirmed the visible rust on the 8 rolling stools and should not been in use.”

    Rule V0111. Standard-level.

  • Ic - Wear Gloves/Hand Hygiene

    The inspectors’ words, 1,244 words

    “IC-WEAR GLOVES/HAND HYGIENE CFR(s): 494.30(a)(1) Wear disposable gloves when caring for the patient or touching the patient’s equipment at the dialysis station. Staff must remove gloves and wash hands between each patient or station. This Standard is not met as evidenced by: 48020 Based on observation, interview and record review, per the TAC 117.33(a)(1)(C)(ii), the facility’s direct care staff: failed to perform hand hygiene after removal of contaminated gloves per the facility’s policy in 4 of 6 staff observed: Patient Care Technician (F), (D), (E), (C) B) failed to change gloves when going from a “dirty” area or task to a “clean” area or task per the facility’s policy in 2 of 6 staff observed: Patient Care Technician (F), (E) Findings: Review of the facility’s current policy and procedure: Infection Control for Dialysis Facilities, Policy 1-05-01, directs the staff as follows: HAND HYGIENE 1. All teammate, Physicians and Non-Physician (NPP) will perform hand hygiene a. upon entering and exiting the patient treatment area, b. prior to gloving and immediately after removal of gloves, c. after contamination with blood or other infectious material, d. after patient and dialysis delivery system contact, e. after interacting with wall boxes ..., f. between patients even if the contact is casual, g. before touching clean areas such as supplies, supply cart and chairside keyboard/mouse ... 3. Use of an alcohol-based hand rub may be substituted for handwashing. a. Hand washing will be performed if hands are visibly contaminated with blood or body fluids and when caring for patients on isolation precautions for Clostridium difficile ... PPE 7. Disposable gloves will be worn when caring for the patient or touching the patient’s equipment at the dialysis station, this will include patients and visitors assisting with procedures such as self-cannulation or holding access sites. a. Gloves should be changed when: i. When soiled with blood, dialysate or other body fluids ii. When going from a “dirty” area or task to a “clean” area or task ... Patient Care Technician (F) Observation on 02/18/2025 at 9:32 a.m., revealed Patient Care Technician (F) was cleaning and disinfecting station #20 after the patient vacated the station. Patient Care Technician (F) wiped the wall box, removed her gloves, reached into the clean glove box and donned a clean pair of gloves without performing hand hygiene. Subsequent observation revealed Patient Care Technician (F) began to wipe the hemodialysis machine and the bleach towel fell to the ground. Patient Care Technician (F) picked up the bleach towel and a food wrapper from the floor and threw them in the waste receptacle. Patient Care Technician (F) then grabbed a new bleach towel that was sitting on the machine and continued to clean the machine with the contaminated gloves. Care Technician (F) failed to remove her gloves and perform hand hygiene after picking up trash on the floor. Interview with Patient Care Technician (F) at 10:07 a.m.: the Surveyor notified Patient Care Technician (F) that she failed to perform hand hygiene after removing her contaminated gloves from cleaning the wall box and she failed to perform a glove change with hand hygiene after picking up trash from the floor. Patient Care Technician (F) said, “Okay.” Patient Care Technician (D) Observation on 02/18/2025 at 9:54 a.m., revealed Patient Care Technician (D) remove the bloodlines from the hemodialysis machine at station #22 after the hemodialysis treatment. Patient Care Technician (D) placed the dirty blood lines into the biohazard, removed her gloves, grabbed clean gloves from the box on the chairside computer cart, donned the clean gloves and walked over to the patient at station #24 and applied the access clamp the patient’s vascular access. Patient Care Technician (D) failed to perform hand hygiene after removing her contaminated gloves. Interview with Patient Care Technician (D) at 10:10 a.m.: the Surveyor notified Patient Care Technician (D) that she failed to perform hand hygiene after removing his contaminated gloves. Patient Care Technician (D) said, “Yes, ma’am.” Patient Care Technician (E) Station #1 Observation of Patient Care Technician (E) on 02/18/2025 at 10:49 a.m. revealed her at station #1 terminating the patient’s hemodialysis treatment. Patient Care Technician (E) disconnected the patient’s blood lines from their vascular access, she removed her gloves, pulled up her face shield and began to type on the chairside computer keyboard without performing hand hygiene. Subsequent observation revealed Patient Care Technician (E) don clean gloves from the box on the chairside computer cart, push down the leg rest of the hemodialysis chair, pull out the footrest, and roll the Sharp’s container to the chairside from the center of the floor. With the same gloves, she picked up a roll of tape from the clean field, tore strips of tape and applied them to the patient’s vascular access for the patient to hold (apply pressure to) his vascular access. Patient Care Technician (E) did not perform a glove change with hand hygiene after touching contaminated objects. Patient Care Technician (E) then removed the dirty bloodlines and bibag from the hemodialysis machine as well as her contaminated gloves. She grabbed clean gloves from the box on the chairside computer cart, donned the gloves and then walked over to the clean supply counter and picked up supplies to set up the machine at station #3. Patient Care Technician (E) did not perform hand hygiene after removing her contaminated gloves. Station #3 Subsequent observation of Patient Care Technician (E) at station #3 revealed she set the clean supplies in the hemodialysis chair, walked over to the gray waste receptacle on wheels, and moved it closer to the hemodialysis machine. With the same gloves she opened the bloodline and dialyzer packages and threw the wrappers into the waste receptacle. She then began to set up the hemodialysis machine at station #3. After setting up the machine, Patient Care Technician (E) pushed the waste receptacle back to the center of the floor, removed her gloves and began to type on the chairside computer cart. Patient Care Technician (E) failed to change her gloves and perform hand hygiene after touching the waste receptacle with her gloves. Interview with Patient Care Technician (E) at 11:00 a.m.: the Surveyor notified Patient Care Technician (E) that she failed to perform hand hygiene after glove removal and she failed to perform a glove change and hand hygiene after touching contaminated objects. Patient Care Technician (E) said, “Okay.” Patient Care Technician (C) Observation of Patient Care Technician (C) on 02/18/2025 at 11:47 a.m. revealed her to cannulate a patient at station #9. The patient’s vascular access was pulsating and blood began to leak out of it. Patient Care Technician (C) immediately applied gauze and pressure to the patient’s vascular access. The patient’s vascular access continued to bleed and soak the gauze with blood. Patient Care Technician (C) continued to change out the bloody gauze until another Patient Care Technician relieved her and stopped the patient’s bleeding. After providing care to the patient, Patient Care Technician (C) removed her bloody gloves and used hand rub to clean her hands. She then grabbed clean supplies from the clean counter, took them to station #8 and began to set up the hemodialysis machine. She failed to wash her hands after contamination with blood or other infectious material as per policy. The Surveyor immediately notified Patient Care Technician (C) that she failed to wash her hands after her gloves became contaminated with visible blood. Patient Care Technician (C) said, “Oh, I was supposed to wash my hands?””

    Rule V0113. Standard-level.

  • Ic - Clean/Dirty Areas, Med Prep Area, No Common Med Carts

    The inspectors’ words, 492 words

    “IC-CLEAN/DIRTY;MED PREP AREA;NO COMMON CARTS CFR(s): 494.30(a)(1)(i) Clean areas should be clearly designated for the preparation, handling and storage of medications and unused supplies and equipment. Clean areas should be clearly separated from contaminated areas where used supplies and equipment are handled. Do not handle and store medications or clean supplies in the same or an adjacent area to that where used equipment or blood samples are handled. When multiple dose medication vials are used (including vials containing diluents), prepare individual patient doses in a clean (centralized) area away from dialysis stations and deliver separately to each patient. Do not carry multiple dose medication vials from station to station. Do not use common medication carts to deliver medications to patients. If trays are used to deliver medications to individual patients, they must be cleaned between patients. This Standard is not met as evidenced by: 48020 Based on observation, interview and record review, the facility’s direct care staff failed to: prevent cross contamination by storing several chairside computer carts in between hemodialysis machines in use (in the splash zone) B) prevent cross contamination by storing a contaminated face shield on the clean computer cart keyboard: Patient Care Technician (C) Findings: Review of the facility’s current policy and procedure: Infection Control for Dialysis Facilities, Policy 1-05-01, directs the staff as follows: “DISINFECTION 15. The chair side cart, terminals mounted on the counter, monitor and keyboard are considered clean areas. FACILITY HYGIENE 16. Clean areas should be clearly designated for the preparation, handling, and storage of medications and unused supplies and equipment. Clean areas should be clearly separated from contaminated areas where used supplies and equipment are handled.” Chairside Carts: Observation of the hemodialysis treatment area on 02/18/2025 at 7:13 a.m. revealed several chairside computer carts stored in between hemodialysis machines in use (in the splash zone). The chairside computer carts were stored between: Stations 1 & 2 Stations 3 & 4 Stations 5 & 6 Stations 7 & 8 Stations 9 & 10 Stations 11 & 12 Stations 17 & 18 Stations 19 & 20 Stations 21 & 22 Stations 23 & 24 The Surveyor notified Charge Nurse (A) during an interview at 8:00 a.m. that the staff failed to prevent cross contamination by storing several chairside computer carts in between hemodialysis machines in use. Charge Nurse (A) said, “Okay, we will pull them out.” Patient Care Technician (C) Observation of Patient Care Technician (C) on 02/18/2025 at 11:47 a.m. revealed her to cannulate a patient at station #9. After providing care the to patient at station #9, Patient Care Technician (C) walked over to station #7, removed her face shield that had condensation on the inside of it and laid it on the keyboard of the chairside computer. The Surveyor immediately notified Patient Care Technician (C) that she failed to prevent cross contamination by laying her contaminated face shield on the clean chairside computer keyboard. Patient Care Technician (C ) said, “Yes, ma’am.””

    Rule V0117. Standard-level.

  • Ic - Clean, Disinfect Surfaces & Equipment/Written Protocols

    The inspectors’ words, 1,402 words

    “IC-DISINFECT SURFACES/EQUIP/WRITTEN PROTOCOL CFR(s): 494.30(a)(4)(ii) [The facility must demonstrate that it follows standard infection control precautions by implementing- (4) And maintaining procedures, in accordance with applicable State and local laws and accepted public health procedures, for the-] (ii) Cleaning and disinfection of contaminated surfaces, medical devices, and equipment. This Standard is not met as evidenced by: 48020 Based on observation, interview and record review, the facility’s direct care staff: failed to clean and disinfect stethoscopes, intravenous poles and rungs, hemodialysis machine, dialysate lines and chase counter tops behind the dialysis stations according to the facility’s policy in 4 of 6 staff observed: Patient Care Technician (F), (E), (O), (P) B) failed to prevent cross contamination by wiping the wall boxes and using the same towel to wipe the chase cabinet and dialysate lines in the back of the hemodialysis machine in 3 of 6 staff observed: Patient Care Technician (F), (O), (P) C) failed to ensure that infection control was maintained as evidenced by hemodialysis chairs with tape and tape residue in 13 of 24 chairs. D) failed to ensure that infection control was maintained as evidenced by tears in the vinyl of the hemodialysis chairs in 2 of 24 chairs. Findings: Review of the facility’s current policy and procedure: Infection Control for Dialysis Facilities, Policy 1-05-01, directs the staff as follows: DISINFECTION 13. At the end of each treatment, the dialysis station will be cleaned and disinfected. a. Surfaces to disinfect include but are not necessarily limited to: all surfaces in contact with the patient or their belongings (e.g., dialysis chair, tray tables, blood pressure cuffs) and frequently contacted by healthcare personnel (e.g., control panel; top, front and sides of dialysis machine; touchscreens; countertops). i. The Wall box, Drain and Water supply lines are considered part of the dialysis delivery system ...” Patient Care Technician (F) Station #19 Disinfection of the hemodialysis station: Observation on 02/18/2025 at 9:51 a.m. revealed Patient Care Technician (F) terminally cleaning station #19 post hemodialysis treatment of a patient. Patient Care Technician (F) failed to clean and disinfect the stethoscope, intravenous pole and rungs, dialysate lines and chase cabinet countertop behind the hemodialysis machine according to policy. Cross contamination of the hemodialysis station: Subsequent observation of Patient Care Technician (F) terminally cleaning station #19 revealed she wiped the wall box and with the same towel, wiped the chase cabinet The Surveyor immediately notified Patient Care Technician (F) that she failed to clean and disinfect the dialysis station according to policy. She was also notified that she failed to prevent cross contamination by wiping the wall box and with the same towel, wiping the chase cabinet at station #19. Patient Care Technician (F) said, “Okay.” Patient Care Technician (E) Station #3 Observation of Patient Care Technician (E) on 02/18/2025 at 10:42 a.m. revealed her at station #3 taping the vascular access of the patient. Patient Care Technician (E) returned to station #3 and began cleaning and disinfecting the blood pressure cuff, the cuff dropped and touched the ground, she wiped the cuff again and hung it on the IV pole of the hemodialysis machine that she did not disinfect. Subsequent observation revealed Patient Care Technician (E) walk over to the patient at station #1 and assist in terminating the patient’s hemodialysis treatment. Patient Care Technician (E) then returned to station #3 and began to clean and disinfect the hemodialysis chair and then she walked over to the clean counter, picked up supplies, returned to station #1 and began to set up the hemodialysis machine. The Surveyor continuously observed Patient Care Technician (E) at station #1 and station #3 and did not see her clean and disinfect the hemodialysis machine, dialysate lines, chase and wall box at station #1. The Surveyor immediately notified Patient Care Technician (E) that she failed to clean the hemodialysis machine, dialysate lines, chase and wall box at station #1. Patient Care Technician (E) said, “Okay. I did clean the machine.” The Surveyor asked her if she was trained to clean the chase and wall box and Patient Care Technician (E) said, “I know that I am supposed to wipe the wall box and chase.” Patient Care Technician (O) Station #17 Disinfection of the hemodialysis station: Observation on 02/19/2025 at 9:55 a.m. revealed Patient Care Technician (O) terminally cleaning station #17 post hemodialysis treatment of a patient. Patient Care Technician (O) failed to clean and disinfect the intravenous pole and rungs, dialysate lines and chase cabinet countertop behind the hemodialysis machine according to policy. Cross contamination of the hemodialysis station: Subsequent observation of Patient Care Technician (O) terminally cleaning station #17 revealed she wiped the wall box and with the same towel, wiped the chase cabinet. Station #18 Disinfection of the hemodialysis station: Observation on 02/19/2025 at 10:06 a.m. revealed Patient Care Technician (O) terminally cleaning station #18 post hemodialysis treatment of a patient. Patient Care Technician (O) failed to clean and disinfect the intravenous pole rungs and chase cabinet countertop behind the hemodialysis machine according to policy. Cross contamination of the hemodialysis station: Subsequent observation of Patient Care Technician (O) terminally cleaning station #18 revealed she wiped the wall box and with the same towel, wiped the chase cabinet and dialysate lines connected to the wall box. The Surveyor immediately notified Patient Care Technician (O) that she failed to clean and disinfect the dialysis station according to policy. She was also notified that she failed to prevent cross contamination by wiping the wall box and with the same towel wiping the chase cabinet and dialysate lines connected to the wall box at station #s 17 and 18. Patient Care Technician (O) said, “Okay.” Patient Care Technician (P) Station #2 Cross contamination of the hemodialysis station: Observation on 02/19/2025 at 10:29 a.m. revealed Patient Care Technician (P) terminally cleaning station #2 post hemodialysis treatment of a patient. Patient Care Technician (P) wiped the wall box and with the same towel, wiped the chase cabinet and dialysate lines connected to the wall box. The Surveyor immediately notified Patient Care Technician (P) that she failed to prevent cross contamination by wiping the wall box and with the same towel, wiping the chase cabinet and the dialysate lines connected to the wall box. Patient Care Technician (P) said, “Yes, ma’am.” Tape and tape residue on hemodialysis chairs: Observation of the hemodialysis treatment area on 02/18/2025 at 10:11 a.m. revealed the following: Stations #s 9, 10, 11, 12, 14, 17, 18, 22, 24- dirty pieces of tape and tape residue on the chairside tables of the hemodialysis chairs at station. Station #11 had clean supply set-up for the next patient on the chairside table with the dirty tape on it. Station #5- dirty pieces of tape and tape residue on the arms of the hemodialysis chair. Station #s 6, 7, 16- dirty pieces of tape and tape residue on the tray tables and arms of the hemodialysis chairs. Interview during the walkthrough with Facility Administrator (H) and Manager of Clinical Safety (N) at 10:20 a.m. confirmed the findings. Tears in vinyl of hemodialysis chairs: Observation of the hemodialysis treatment area on 02/18/2025 at 10:00 a.m. revealed the following: Two hemodialysis chairs had tears in the vinyl: Stations #22- The hemodialysis chair has three tears in the vinyl of the seat cushion the look like a cross. There is a vertical tear that runs from the back of the seat cushion to the middle and has some of the vinyl is missing exposing the material underneath. There are two horizontal tears, one on each side of the vertical tear. Both of the horizontal tears have the tape that is used to tape vascular accesses on them holding them together. The vinyl on the arms of the chair also has small tears. During the observation, the Surveyor observed a patient receiving a hemodialysis treatment and after the seat was vacated, Patient Care Technician (D) attempted to clean and disinfect the chair. Interview with Patient Care Technician (D) at 10:10 a.m. confirmed the hemodialysis chair should have been removed from the treatment area. Patient Care Technician (D) said, “It’s supposed to be pulled but it is still here, so I just cleaned it.” Station #16- The hemodialysis chair had small tears in the arms and seat cushion of hemodialysis chair. Interview during the walkthrough with Facility Administrator (H) and Manager of Clinical Safety (N) at 10:20 a.m. confirmed the findings above.”

    Rule V0122. Standard-level.

  • Md Resp - Ensure All Adhere To P&P

    The inspectors’ words, 286 words

    “MD RESP-ENSURE ALL ADHERE TO P&P CFR(s): 494.150(c)(2)(i) The medical director must- (2) Ensure that- (i) All policies and procedures relative to patient admissions, patient care, infection control, and safety are adhered to by all individuals who treat patients in the facility, including attending physicians and nonphysician providers; This Standard is not met as evidenced by: 48020 Based on observation, interview and record review, per the TAC 117.33(b)(1)(A), the facility’s nurses failed to perform the daily automated external defibrillator (AED) checks as required by the facility’s policy. Findings: Review of the facility’s current policy and procedure: Emergency Equipment Checks, Policy #05-02-08, directs staff as follows: PURPOSE: Verify that emergency equipment is maintained in a ready-to-use condition. POLICY: 1. Emergency equipment, including, but not limited to, oxygen, airways, suction, automated external defibrillator (AED), and artificial resuscitator (ambu bag), and emergency drugs will be on the premises at all times. 2. The following equipment checks will be performed by a licensed nurse teammate to verify the designated equipment is available and functional: Daily: “ Check Status Indicator light for Philips Heart Start FR2+ ... “ Check Status Indicator for green check for Zoll AED ... “ Manufacturer’s AED pads are present on cart “ Break away lock is intact Emergency Cart: Observation of the emergency cart on 02/18/2025 at 8:03 a.m. revealed a Zoll AED Plus automated external defibrillator sitting on top of the emergency cart. Review of the DAILY ZOLL AED and Emergency Medication Lock Log, Procedure: 1-02-08E revealed daily check was not performed on the following days: 08/06/2024, 08/13/2024, 11/15/2024, 12/02/2024, 12/10/2024, 12/19/2024, 01/07/2025, and 01/30/2025. Interview during the walkthrough with Facility Administrator (H) and Manager of Clinical Safety (N) at 10:20 a.m. confirmed the findings.”

    Rule V0715. Standard-level.

All 2 inspections in the last three years
Inspections on record
DateVisitWhat the record says
Mar 26, 2025Complaint inspectionNo deficiencies cited
Feb 19, 2025Standard inspection6 deficiencies cited

Is it certified?

  • Medicare-certified dialysis facility, certified or last recertified on Sep 2, 1994.
  • Run for profit.
  • Cited at in the last three years: it didn’t meet a whole condition of Medicare’s rules for dialysis facilities.
  • Chain: DaVita.
Source:

CMS, Dialysis Facility - Listing by Facility. Released Jul 15, 2026. Updated quarterly.

CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.

Has it been penalized?

  • CMS doesn’t publish fines or other penalties for dialysis facilities.
  • None of the deficiencies cited in the last three years came from an inspection that included a complaint investigation.
Source:

CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.

What does it offer?

  • Offers in-center hemodialysis.
  • Doesn’t offer peritoneal dialysis, home hemodialysis training and a shift starting at 5 p.m. or later.
  • 25 dialysis stations.
  • CMS doesn’t publish staffing levels for dialysis facilities.
  • In CMS’s survey, patients rate its staff 1 of 5.
Source:

CMS, Dialysis Facility - Listing by Facility and Patient survey (ICH CAHPS) - Facility. Released Jul 15, 2026. Updated quarterly.

Who owns it?

  • Part of the DaVita chain, as CMS lists it.
  • CMS publishes no owners file for dialysis facilities, so no other owner is named.
Source:

CMS, Dialysis Facility - Listing by Facility. Released Jul 15, 2026. Updated quarterly.

How do patients fare?

  • CMS rates it 1 of 5 stars (Jan 1, 2021 to Dec 31, 2024).
  • Compared by CMS with what it expects for the facility’s patients: patient survival, as expected; hospital admissions, worse than expected; readmissions to hospital, as expected; emergency department visits, worse than expected; emergency department visits within 30 days of a hospital stay, as expected; bloodstream infections, better than expected; patients dialysing through a fistula, as expected; patients put on a kidney transplant waitlist in their first year of dialysis, as expected; patients on a kidney transplant waitlist, as expected.
  • Patients rate it 1 of 5 in CMS’s survey of in-center hemodialysis patients (36 interviews, Oct 18, 2024 to Jul 11, 2025): 59% rated the facility 9 or 10 out of 10.
Source:

CMS, Dialysis Facility - Listing by Facility and Patient survey (ICH CAHPS) - Facility. Released Jul 15, 2026. Updated quarterly.

Ratings and measures, as published
MeasureRating
Star ratingCMS’s star rating for dialysis facilities, 1 to 51 of 5
Patient survey ratingCMS star rating from its survey of the facility’s in-center hemodialysis patients (ICH CAHPS), 1 to 51 of 5

How does it compare nearby?

  • Of the 137 dialysis facilities CMS lists in Harris County, 124 have a star rating from CMS: 4 rated 5 of 5, 11 rated 4 of 5, 53 rated 3 of 5, 41 rated 2 of 5, 15 rated 1 of 5.
  • CMS rates this one 1 of 5.
Source:

CMS, Dialysis Facility - Listing by Facility. Released Jul 15, 2026. Updated quarterly.

What the record doesn’t say

  • CMS doesn’t publish fines or other penalties for dialysis facilities, so none are shown.
  • Only complaints that led to a citation appear; complaints that didn’t aren’t published.
  • QCOR says it has no dialysis inspection reports after February 19, 2026, while it moves to a new system: a later inspection is not shown yet.
  • CMS doesn’t publish staffing levels for dialysis facilities.
  • CMS publishes no owners file for dialysis facilities: the chain it lists is the only owner named.

Sources

If you believe something here is wrong, a correction starts with the agency whose record this copies: CMS. CMS’s own record is on Care Compare. If Hearth Record copied something wrongly, it will fix it and log the correction publicly, with its date: how corrections work.

Source:

This copy of the record was made on Oct 30, 2026.

From the facility

The public record above comes first. Anything the facility adds will appear here, below it, and say who wrote it.

Replies

None. Replies aren’t open yet. When they open, the facility will be able to answer any finding for free, and the reply will show beside that finding, unedited and dated.

Paid listing

None. Paid listings aren’t open yet. When they open, anything paid for will say “Paid by the facility”, and paying will never change a finding, a rating or the order of results.

How to read a record

Four things every record does, shown on an example record made up for this guide.

An example record, made up for this guide

An example nursing home

Made up for this guide: no real place is shown

Not fully inspected in over two years (CMS flag)

11 health citations at the latest inspection cycle

The state average is 14.3.

Source:

CMS, State and US Averages and Health Deficiencies. Released Oct 28, 2026. Updated monthly.

From the homeNone yet. Replies and paid listings aren’t open, and when they open they will sit here, below the record.

1 of 4

Every fact names its source.

Who published it, when, and how often it changes sit beside each fact, with a link to the agency’s own file.

Sign in

A free account keeps your watch list, shortlists, comparisons and saved searches on every device, and can email you when something you watch changes. Browsing never needs one.