Hearth Record

Fmc Columbia

A dialysis facility in Columbia, Tennessee 38401

861 West James Campbell Blvd, Columbia, Tennessee 38401. (931) 380-9099.

CMS’s own record, on Care Compare

Watch and the shortlist are kept with a free account, on every device. Your watch list. CMS’s own record is on Care Compare.

The short answer

Record last released by CMS on Oct 28, 2026.

The last 24 months 8 deficiencies in 1 month of the last 36. Last cited May 2025. Most serious: Standard-level. Every month

Each figure’s source sits beside it, in its section below.

What these words mean3
Star ratings
CMS rates some kinds of place from 1 to 5 stars, more stars meaning better on CMS’s own measures for that kind: for a nursing home, its health inspections, staffing and quality measures. A rating is CMS’s summary of those measures; it doesn’t promise good care. Source: CMS, Care Compare and the Five-Star Quality Rating System.
Inspection (survey)
A visit by state inspectors, often unannounced, who check a place against the rules it must meet. For nursing homes and other places Medicare pays, CMS calls these visits surveys: a standard survey of a nursing home comes at least every 15 months, and a complaint survey whenever a complaint calls for one. Source: CMS; 42 CFR 488.308.
Deficiency, citation, violation
What inspectors write up when a place didn’t meet a rule: the rule, what they saw, and when. CMS calls it a deficiency; states may say citation or violation. It is the inspectors’ finding, not a court’s, and the place is usually asked for a plan to correct it. Source: CMS, statement of deficiencies (Form CMS-2567); each state’s licensing agency.

What did inspectors find?

The last inspection on record was on May 7, 2025: a standard inspection.

8 deficiencies cited in the last three years.

Source:

CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.

When those deficiencies happened

8 deficiencies in 1 month of the last 36. Last cited May 2025. Most serious: Standard-level. The last 3 years, to Oct 30, 2026.

8 deficiencies by month over the last 3 years. Each cell is one month.
JanFebMarAprMayJunJulAugSepOctNovDec
2023 NovDec
2024 JanFebMarAprMayJunJulAugSepOctNovDec
2025 JanFebMarAprMayJunJulAugSepOctNovDec
2026 JanFebMarAprMayJunJulAugSepOct

Hover or focus a month to read it.

No visit on record Visited, nothing cited A stronger orange is more serious, on its source’s own levels, read onto four bands: from the least serious it publishes to the most
Source:

Hearth Record drew this from the dates and levels in the source’s own records.

Each deficiency, as cited

Rule titles as CMS’s inspectors cite them, set in sentence case.

Source:

CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.

May 7, 2025: standard inspection8 deficiencies
  • Ic - Wear Gloves/Hand Hygiene

    The inspectors’ words, 227 words

    “IC-WEAR GLOVES/HAND HYGIENE CFR(s): 494.30(a)(1) Wear disposable gloves when caring for the patient or touching the patient’s equipment at the dialysis station. Staff must remove gloves and wash hands between each patient or station. This Standard is not met as evidenced by: 49570 Based on facility policy review, observation and interview, the facility failed to ensure hand hygiene was performed according to facility policy to prevent the spread of infectious bacteria by 2 of 2 (RN #3 and CCHT #2) staff members observed in the lab area. The findings included: 1. Review of facility policy, “Hand Hygiene” published 11/06/2023 revealed, “ ...prevent transmission of pathogenic microorganisms to patients and staff through cross contamination...hands will be ...decontaminated using alcohol-based hand rub or by washing hands with antimicrobial soap and water when ...before and after direct contact with patients ...entering and leaving the treatment area ...Immediately after removing gloves ...” 2. Observations in the lab area on 05/05/2025 at 10:44 AM, revealed RN #3 and CCHT #2 opened the lab refrigerator door with gloved hands. The front of the refrigerator contained two 8.5 in. x 11 in. size signs that stated, “REMOVE GLOVES AND SANITIZE HANDS BEFORE TOUCHING REFREIGERATOR.” 3. During an interview on 05/07/2025 at 11:18 AM, the CM verified that hand hygiene should be performed before and after removing gloves and before opening the lab refrigerator door.”

    Rule V0113. Standard-level.

  • Ic - Sinks Available

    The inspectors’ words, 197 words

    “IC-SINKS AVAILABLE CFR(s): 494.30(a)(1)(i) A sufficient number of sinks with warm water and soap should be available to facilitate hand washing. This Standard is not met as evidenced by: 49570 Based on facility policy review, observation, and interview, the facility failed to ensure infection control measures were taken to protect items from contamination at 1 of 3 (Handwashing Sink #1) handwashing sinks. The findings included: 1. Review of facility policy, “Hand Hygiene” published 03/17/2023 revealed, “ ...to prevent transmission of pathogenic microorganisms to patients and staff through cross contamination ...Sink Policy: The hand washing sinks may be used for both staff and patients. Soap and a supply of paper towels protected from contamination must be available at each sink ...” 2. Observations on the treatment floor on 05/05/2025 at 11:20 AM, revealed 18 packs of closed and 1 pack of open absorbent wipes (used to disinfect patient care items with bleach and dry areas washed) sitting around the sink that was being used by patients and staff for handwashing. 3. During an interview on 05/07/2025 at 11:18 AM, the CM confirmed that absorbent wipes should not be placed around the sink due to the potential for contamination.”

    Rule V0114. Standard-level.

  • Ic - Clean/Dirty Areas, Med Prep Area, No Common Med Carts

    The inspectors’ words, 287 words

    “IC-CLEAN/DIRTY;MED PREP AREA;NO COMMON CARTS CFR(s): 494.30(a)(1)(i) Clean areas should be clearly designated for the preparation, handling and storage of medications and unused supplies and equipment. Clean areas should be clearly separated from contaminated areas where used supplies and equipment are handled. Do not handle and store medications or clean supplies in the same or an adjacent area to that where used equipment or blood samples are handled. When multiple dose medication vials are used (including vials containing diluents), prepare individual patient doses in a clean (centralized) area away from dialysis stations and deliver separately to each patient. Do not carry multiple dose medication vials from station to station. Do not use common medication carts to deliver medications to patients. If trays are used to deliver medications to individual patients, they must be cleaned between patients. This Standard is not met as evidenced by: 49570 Based on facility policy review, manufacturer’s guidelines for use and storage, observation, and interview, the facility failed to ensure the proper storage of medications to ensure patient safety measures were followed on 1 of 1 (05/05/2025) observation days. The findings included: 1. Review of facility policy, “Medication Preparation and Administration” published 02/06/2023 revealed, “ ...Medication refrigerators are designated for the storage of medications ...” 2. Review of the manufacturer’s guidelines for use and storage revealed, “ ...store between 2°-8° C (36°-46° F) ...” 3. Observations in the supply storage area on 05/05/2025 at 9:30 AM, revealed three (3) 0.5 mL pre-filled influenza vaccines sitting on top of lab vacutainers instead of inside the medication refrigerator. 4. During an interview on 05/06/2025 at 11:18 AM, the CM confirmed that medications intended for storage in the refrigerator should always be kept in the refrigerator.”

    Rule V0117. Standard-level.

  • Ic - Aseptic Techniques For Iv Meds

    The inspectors’ words, 354 words

    “IC-ASEPTIC TECHNIQUES FOR IV MEDS CFR(s): 494.30(b)(2) [The facility must-] (2) Ensure that clinical staff demonstrate compliance with current aseptic techniques when dispensing and administering intravenous medications from vials and ampules; and This Standard is not met as evidenced by: 49570 Based on facility policy review, observation and interview, the facility failed to ensure medications were labeled according to facility policy or discarded before their expiration date in 4 of 6 (3rd nursing station, medication room, main medication station, and medication refrigerator) medication prep/storage areas. The findings included: 1. Review of facility policy, “Medication Preparation and Administration” published 02/06/2023, revealed, “To administer medications with the goals of staff and patient safety, optimal therapeutic response, and infection control ...All medications in syringes not being administered immediately shall be labeled appropriately with the name of the medication, route, dose, name of patient, date, time and initials of the person who prepared the medication ...Expiration dates for all stored medications are to be monitored on a monthly basis. Expired medications are to be discarded ...” 2. Observations at the main medication station on 05/05/2025 at 9:00 AM, revealed seven (7) vials of Ceftriaxone (antibiotic) 1 g with an expiration date of 02/2025. Observations at the medication refrigerator on 05/05/2025 at 9:10 AM, revealed nine (9) syringes of Influenza vaccine with an expiration date of 04/2025. Observations at the 3rd nurses’ station on 05/05/2025 at 10:00 AM, revealed four (4) Hep Lock 2ml syringes labeled with no initial or time. Observations in the medication room on 05/05/2025 at 10:20 AM, revealed one (1) bottle of calcium carbonate (dietary supplement used to treat low levels of calcium) 750 mg opened with no label, time, date, or initials. 3. During an interview on 05/05/2025 at 10:15 AM, RN #1 verified the above medications were not labeled per facility policy and confirmed that she had drawn up the medications earlier that morning and did not properly label the syringes. During an interview on 05/07/2025 at 11:18 AM, the CM verified that medications should be labeled per facility policy and should be checked monthly and discarded on or before their expiration date.”

    Rule V0143. Standard-level.

  • Ic - Staff Education Re Catheters/Catheter Care

    The inspectors’ words, 344 words

    “IC-STAFF EDUCATION-CATHETERS/CATHETER CARE CFR(s): 494.30(a)(2) Recommendations for Placement of Intravascular Catheters in Adults and Children I. Health care worker education and training A. Educate health-care workers regarding the ... appropriate infection control measures to prevent intravascular catheter-related infections. B. Assess knowledge of and adherence to guidelines periodically for all persons who manage intravascular catheters. II. Surveillance A. Monitor the catheter sites visually of individual patients. If patients have tenderness at the insertion site, fever without obvious source, or other manifestations suggesting local or BSI [blood stream infection], the dressing should be removed to allow thorough examination of the site. Central Venous Catheters, Including PICCs, Hemodialysis, and Pulmonary Artery Catheters in Adult and Pediatric Patients. VI. Catheter and catheter-site care B. Antibiotic lock solutions: Do not routinely use antibiotic lock solutions to prevent CRBSI [catheter related blood stream infections]. This Standard is not met as evidenced by: 46831 Based on facility policy review, observation, and interview, the facility failed to ensure measures to prevent CVC related infections were followed for 1 of 1 (Patient #8). The findings included: 1. Review of the facility policy titled “Termination of Treatment Using a Central Venous Catheter and Optiflux Single Use Ebeam Dialyzer” published 02/07/2022, revealed, “...The following supplies are needed for this procedure...Under pad-if existing pad is soiled...Ensure that a clean under pad is below the catheter limbs to protect the work area and the clothing...” 2. Medical record review for Patient #8 revealed an admission date of 03/14/2024 with diagnoses which included Hypertensive Chronic Kidney Disease and ESRD. Review of the physician’s order dated 4/25/2025 revealed Patient #8 was to receive hemodialysis treatments via AVF three times a week. 3. Observations at Station #36 on 05/05/2025 at 11:50 AM, revealed blood present on the under pad beneath the CVC. RN #2 began to perform discontinuation of treatment of a CVC and did not place a clean under pad beneath Patient #8’s catheter. 4. During an interview on 05/07/2025 at 11:18 AM, the CM stated a new under pad should be placed under the CVC when visibly soiled.”

    Rule V0147. Standard-level.

  • Pe - Safe, Functional, Comfortable Environment

    The inspectors’ words, 368 words

    “PE-SAFE/FUNCTIONAL/COMFORTABLE ENVIRONMENT CFR(s): 494.60 The dialysis facility must be designed, constructed, equipped, and maintained to provide dialysis patients, staff, and the public a safe, functional, and comfortable treatment environment. This Standard is not met as evidenced by: 49570 Based on facility policy review, observation, and interview, the facility failed to follow infection control measures by not ensuring supplies were discarded before their expiration date on 1 of 1 (05/05/2025) observation days in 2 of 9 (crash cart and clean cart area 4) supply storage areas and failed to provide a safe environment by not locking 1 of 1 crash carts located on the treatment floor. The findings included: 1. Review of facility policy, “Emergency Medications, Equipment and Supplies” published 02/03/2025, revealed, “ ...An emergency cart, sometimes called ‘crash cart’ ...The Emergency cart must be checked monthly or after use for contents, expirations dates...Items approaching expiration must be reordered and replaced prior to the actual expiration date ... An emergency evacuation box must be checked monthly ...for ...expiration dates ...Items approaching expiration must be reordered and replaced prior to the actual expiration date ...The Emergency cart must be locked when not in use ...” Review of facility policy, “Storage of Supplies” published 04/05/2021 revealed, “ ...Proper storage conditions are necessary to provide a safe environment and to ensure supplies are not expired ...Supplies must be rotated First in-First Out (FIFO) to ensure products maintain quality and do not expire. Appropriately dispose of items that have reached the expiration date ...” 2. Observations at the crash cart on 05/05/2025 at 11:30 AM, revealed the following expired supplies: Four (4) Tri-Flo Suction Catheters with an expiration date of 09/30/2024 Two (2) Vacutainer Blood Collection Sets with an expiration date of 04/30/2025 Observations in Clean Cart Area #4 on 05/05/2025 at 11:40 AM, revealed two (2) 50 mL syringes with an expiration date of 10/31/2024. Observations on the treatment floor on 05/05/2025 at 10:45 AM, revealed 1 of 1 crash carts unlocked and accessible to staff and patients. During an interview on 05/05/2025 at 11:18 AM the CM verified that all supplies should be routinely checked and discarded when expired and verified that the crash cart should be locked at all times.”

    Rule V0401. Standard-level.

  • Manage Volume Status

    The inspectors’ words, 2,140 words

    “POC-MANAGE VOLUME STATUS CFR(s): 494.90(a)(1) The plan of care must address, but not be limited to, the following: (1) Dose of dialysis. The interdisciplinary team must provide the necessary care and services to manage the patient’s volume status; This Standard is not met as evidenced by: 46831 Based on facility policy review, medical record review and interview, the facility failed to implement measures to address hypertensive episodes for 5 of 10 (Patient #1, #2, #3, #7 and #10) sampled patients. The findings included: 1. Review of the undated facility policy titled “Standing Orders 2025 ...MD Specific Blood Pressure and Heart Rate Parameters” revealed, “...Notify MD for permission to START tx if ...SBP<100 or >190, DBP>110 or <40, HR>120 or <40...Hypertension...Intradialytic HTN...Clonidine 0.1 mg PRN may repeat Q1 hour x3 for persistent SBP>190mmHg...Hypotension ...Sustained Hypotension during tx...NS 200ml Bolus, may repeat x2. Repeat BP in 5-10 min after each administration...check bp q 10 min until stable...” Review of the facility policy titled “Hypertension” published 09/07/2021, revealed, “...Treating Hypertension...Notify the nurse in charge if a patient has a systolic blood pressure greater than 180 mm/Hg and/or diastolic blood pressure greater than 100 mm/Hg...The RN will assess the patient and determine if further nursing interventions are needed...Document in patient’s treatment record...” Review of the facility policy titled “Hypotension” published 05/06/2024, revealed, “...Treating Hypotension...The PCT must immediately report signs and symptoms to the [ESRD Company] RN...The [ESRD Company] RN will assume care of the patient...Document in the [ESRD Company] treatment record and/or Contracted Entity electronic documentation system per contractual agreement...” 2. Medical record review for Patient #1 revealed an admission date of 3/11/2025 with diagnoses which IgA Nephropathy, Berger’s Disease, and End Stage Renal Disease. Review of the physician’s orders dated 04/25/2025 revealed the Patient was to receive in-center hemodialysis treatments 3 times a week via a CVC. Review of the Treatment Sheet dated 04/07/2025, revealed missed blood pressure documentation during treatment. The treatment was initiated at 12:53 PM and ended at 4:18 PM. The Patient’s blood pressures were as follows: 180/101 at 2:02 PM 175/101 at 2:34 PM 175/101 at 2:46 PM 182/100 at 3:00 PM Facility staff failed to address Patient #1’s high blood pressures. There was no documentation the CN was notified or completed an assessment on the patient. Review of the Treatment Sheet dated 04/14/2025, revealed missed blood pressure documentation during treatment. The treatment was initiated at 12:10 PM and ended at 4:12 PM. The Patient’s blood pressures were as follows: 189/101 at 12:18 PM 184/108 at 12:49 PM 180/104 at 1:00 PM 181/104 at 1:42 PM 178/102 at 2:02 PM 177/100 at 2:23 PM 196/107 at 2:54 PM 189/104 at 3:04 PM 197/101 at 3:29 PM 208/105 at 4:03 PM 185/115 at 4:12 PM Facility staff failed to address Patient #1’s high blood pressures. There was no documentation the CN was notified or completed an assessment on the patient. Review of the Treatment Sheet dated 04/25/2025, revealed missed blood pressure documentation during treatment. The treatment was initiated at 11:57 AM and ended at 3:44 PM. The Patient’s blood pressures were as follows: 189/104 at 12:23 PM 187/101 at 12:23 PM 191/98 at 2:45 PM 184/94 at 3:02 PM 192/102 at 3:24 PM Facility staff failed to address Patient #1’s high blood pressures. There was no documentation the CN was notified or completed an assessment on the patient. Review of the Treatment Sheet dated 04/28/2025, revealed missed blood pressure documentation during treatment. The treatment was initiated at 12:17 PM and ended at 4:24 PM. The Patient’s blood pressures were as follows: 188/105 at 12:18 PM. Facility staff failed to address Patient #1’s high blood pressure. There was no documentation the CN was notified or completed an assessment on the patient. Review of the Treatment Sheet dated 05/02/2025, revealed missed blood pressure documentation during treatment. The treatment was initiated at 12:15 PM and ended at 4:22 PM. The Patient’s blood pressures were as follows: 199/105 at 12:19 PM 161/103 at 12:44 PM 181/92 at 1:04 PM 177/102 at 1:22 PM 184/98 at 1:41 PM Facility staff failed to address Patient #1’s high blood pressures. There was no documentation the CN was notified or completed an assessment on the patient. 3. Medical record review for Patient #2 revealed an admission date of 4/20/2023 with diagnoses which included Systemic Lupus Erythematosus and End Stage Renal Disease. Review of the physician’s orders dated 04/16/2025, revealed the Patient was to receive in-center hemodialysis treatments 3 times a week via AVF. Review of the Treatment Sheet dated 03/26/2025, revealed missed blood pressure documentation during treatment. The treatment was initiated at 9:49 AM and ended at 2:09 PM. The Patient’s blood pressures were as follows: 169/105 at 10:14 AM 174/103 at 10:23 AM 173/105 at 10:55 AM Facility staff failed to address Patient #2’s high blood pressures. There was no documentation the CN was notified or completed an assessment on the patient. Review of the Treatment Sheet dated 04/09/2025, revealed missed blood pressure documentation during treatment. The treatment was initiated at 10:23 AM and ended at 2:23 PM. The Patient’s blood pressures were as follows: 158/100 at 11:03 AM 163/103 at 12:08 PM 166/100 at 1:02 PM 165/102 at 1:22 PM Facility staff failed to address Patient #2’s high blood pressures. There was no documentation the CN was notified or completed an assessment on the patient. Review of the Treatment Sheet dated 4/11/2025, revealed missed blood pressure documentation during treatment. The treatment was initiated at 10:31 AM and ended at 2:36 PM. The Patient’s blood pressures were as follows: 175/105 at 11:21 AM Facility staff failed to address Patient #2’s high blood pressure. There was no documentation the CN was notified or completed an assessment on the patient. Review of the Treatment Sheet dated 4/16/2025, revealed missed blood pressure documentation during treatment. The treatment was initiated at 10:36 AM and ended at 2:37 PM. The Patient’s blood pressures were as follows: 173/101 at 12:53 PM 183/109 at 2:02 PM Facility staff failed to address Patient #2’s high blood pressures. There was no documentation the CN was notified or completed an assessment on the patient. Review of the Treatment Sheet dated 4/23/2025, revealed missed blood pressure documentation during treatment. The treatment was initiated at 10:04 AM and ended at 2:06 PM. The Patient’s blood pressures were as follows: 169/105 at 10:04 AM 179/104 at 10:23 AM 186/106 at 10:42 AM 211/109 at 11:09 AM 209/116 at 11:26 AM 189/118 at 11:41 AM 183/101 at 12:07 PM Facility staff failed to address Patient #2’s high blood pressures. There was no documentation the CN was notified or completed an assessment on the patient. 4. Medical record review for Patient #3 revealed an admission date of 07/28/2023 with diagnoses which included Acute Kidney Failure and End Stage Renal Disease. Review of the physician’s orders dated 05/02/2025, revealed the Patient was to receive in-center hemodialysis treatments 3 times a week via an CVC. Review of the Treatment Sheet dated 04/04/2025, revealed missed blood pressure documentation during treatment. The treatment was initiated at 10:47 AM and ended at 2:14 PM. The Patient’s blood pressures were as follows: 171/126 at 1:31 PM Facility staff failed to address Patient #3’s high blood pressure. There was no documentation the CN was notified or completed an assessment on the patient. Review of the Treatment Sheet dated 04/07/2025, revealed missed blood pressure documentation during treatment. The treatment was initiated at 11:06 AM and ended at 2:23 PM. The Patient’s blood pressures were as follows: 96/40 at 2:22 PM Facility staff failed to address Patient #3’s low blood pressure. There was no documentation the CN was notified or completed an assessment on the patient. Review of the Treatment Sheet dated 04/09/2025, revealed missed blood pressure and pulse documentation during treatment. The treatment was initiated at 10:58 AM and ended at 1:58 PM. The Patient’s blood pressures were as follows: 140/108 at 1:00 PM 92/72 at 1:44 PM Facility staff failed to address Patient #3’s blood pressures. There was no documentation the CN was notified or completed an assessment on the patient. Review of the Treatment Sheet dated 04/11/2025, revealed missed blood pressure and pulse documentation during treatment. The treatment was initiated at 10:40 AM and ended at 1:41 PM. The Patient’s blood pressures were as follows: 89/70 at 11:01 AM 99/58 at 1:29 PM Patient’s pulse was as follows: 37 at 11:24 AM Facility staff failed to address Patient #3’s low blood pressure and pulse. There was no documentation the CN was notified or completed an assessment on the patient. Review of the Treatment Sheet dated 04/14/2025, revealed missed blood pressure documentation during treatment. The treatment was initiated at 11:07 AM and ended at 2:14 PM. The Patient’s blood pressures were as follows: 96/67 at 12:22 PM 99/56 at 1:50 PM 91/55 at 2:13 PM Facility staff failed to address Patient #3’s low blood pressures. There was no documentation the CN was notified or completed an assessment on the patient. Review of the Treatment Sheet dated 04/21/2025, revealed missed blood pressure documentation during treatment. The treatment was initiated at 10:47 AM and ended at 1:59 PM. The Patient’s blood pressures were as follows: 88/54 at 11:13 AM 97/54 at 11:14 AM 90/44 at 11:20 AM 98/50 at 11:46 AM 99/59 at 12:42 PM Facility staff failed to address Patient #3’s low blood pressures. There was no documentation the CN was notified or completed an assessment on the patient. Review of the Treatment Sheet dated 05/02/2025, revealed missed blood pressure and pulse documentation during treatment. The treatment was initiated at 10:48 AM and ended at 1:48 PM. The Patient’s blood pressures were as follows: 147/104 at 1:09 PM. Facility staff failed to address Patient #3’s high blood pressure. There was no documentation the CN was notified or completed an assessment on the patient. 5. Medical record review for Patient #7 revealed an admission date of 03/14/2024 with diagnoses which included Hypertensive Chronic Kidney Disease and End Stage Renal Disease. Review of the physician’s orders dated 04/30/2025 revealed the Patient was to receive in-center hemodialysis treatments 3 times a week via an CVC. Review of the Treatment Sheet dated 03/31/2025, revealed missed blood pressure and pulse documentation during treatment. The treatment was initiated at 11:38 AM and ended at 1:45 PM. The Patient’s blood pressures were as follows: 85/39 at 1:02 PM 90/43 at 1:30 PM 84/41 at 1:32 PM Facility staff failed to address Patient #7’s low blood pressures. There was no documentation the CN was notified or completed an assessment on the patient. Review of the Treatment Sheet dated 05/02/2025, revealed missed blood pressure documentation during treatment. The treatment was initiated at 11:32 AM and ended at 2:56 PM. The Patient’s blood pressures were as follows: 97/56 at 1:21 PM 98/54 at 1:47 PM 84/52 at 2:05 PM 88/57 at 2:22 PM Facility staff failed to address Patient #7’s low blood pressures. There was no documentation the CN was notified or completed an assessment on the patient. 6. Medical record review for Patient #10 revealed an admission date of 07/07/2023 with diagnoses which included Type 2 Diabetes Meletus and End Stage Renal Disease. Review of the physician’s orders dated 04/09/2025, revealed the Patient was to receive in-center hemodialysis treatments 3 times a week via an AVF. Review of the Treatment Sheet dated 04/09/2025, revealed missed blood pressure documentation during treatment. The treatment was initiated at 10:17 AM and ended at 2:35 PM. The Patient’s blood pressures were as follows: 94/60 at 11:40 AM 94/60 at 11:53 AM 92/58 at 12:00 PM 92/54 at 12:20 PM 97/59 at 12:42 PM 92/60 at 2:35 PM Facility staff failed to address Patient #10’s low blood pressures. There was no documentation the CN was notified or completed an assessment on the patient. Review of the Treatment Sheet dated 04/14/2025, revealed missed blood pressure documentation during treatment. The treatment was initiated at 10:20 AM and ended at 2:39 PM. The Patient’s blood pressures were as follows: 98/61 at 1:48 PM 91/50 at 2:07 PM Facility staff failed to address Patient #10’s low blood pressure. There was no documentation the CN was notified or completed an assessment on the patient. Review of the Treatment Sheet dated 04/25/2025 revealed missed blood pressure documentation during treatment. The treatment was initiated at 10:11 AM and ended at 2:34 PM. The Patient’s blood pressures were as follows: 94/63 at 10:44 AM 98/57 at 11:40 AM 93/51 at 2:24 PM Facility staff failed to address Patient #10’s low blood pressures. There was no documentation the CN was notified or completed an assessment on the patient. 7. During an interview on 05/07/2025 at 11:18 AM, the CM stated if a patient experienced hypertension or hypotension during treatment, the PCT/CCHT should notify the CN, who should then assess the patient. The CM stated that all staff should document their notifications and interventions.”

    Rule V0543. Standard-level.

  • Vascular Access - Monitor/Referrals

    The inspectors’ words, 238 words

    “POC-VASCULAR ACCESS-MONITOR/REFERRALS CFR(s): 494.90(a)(5) The interdisciplinary team must provide vascular access monitoring and appropriate, timely referrals to achieve and sustain vascular access. The hemodialysis patient must be evaluated for the appropriate vascular access type, taking into consideration co-morbid conditions, other risk factors, and whether the patient is a potential candidate for arteriovenous fistula placement. This Standard is not met as evidenced by: 51246 Based on facility policy review, observation, and interview, the facility failed to ensure infection control measures were taken during initiation and discontinuation of hemodialysis with an AVG/AVF on 1 of 2 (05/05/2025) observation days. The findings included: 1. Review of facility policy “Access Assessment and Cannulation” published 05/05/2025 revealed, “...Skin Disinfection: Step 1: Disinfect cannulation site as follows...70% isopropyl alcohol pad: using gentle friction, clean the access site beginning in the center and continuing outward 2 inches in a concentric circle for 30 seconds and allow to dry before cannulating...Do not touch cannulation sites after skin disinfection...” 2. Observations at Station #31 on 05/05/2025 at 10:03 AM, revealed PCT #1 initiated hemodialysis on Patient #10. PCT #1 palpated and cleaned the access site, then re-palpated the access site with a gloved finger. PCT #1 failed to reclean the site before cannulation and did not allow for dry time. 3. During an interview on 05/07/2025 at 11:18 PM, the CM verified that if PCT #1 palpated the access site, it should have been re-cleaned before cannulation.”

    Rule V0550. Standard-level.

The one inspection in the last three years
Inspections on record
DateVisitWhat the record says
May 7, 2025Standard inspection8 deficiencies cited

Is it certified?

  • Medicare-certified dialysis facility, certified or last recertified on Apr 29, 1998.
  • Run for profit.
  • No deficiency on record in the last three years.
  • Chain: Fresenius Medical Care.
Source:

CMS, Dialysis Facility - Listing by Facility. Released Jul 15, 2026. Updated quarterly.

CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.

Has it been penalized?

  • CMS doesn’t publish fines or other penalties for dialysis facilities.
  • None of the deficiencies cited in the last three years came from an inspection that included a complaint investigation.
Source:

CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.

What does it offer?

  • Offers in-center hemodialysis, peritoneal dialysis and home hemodialysis training.
  • Doesn’t offer a shift starting at 5 p.m. or later.
  • 42 dialysis stations.
  • CMS doesn’t publish staffing levels for dialysis facilities.
  • In CMS’s survey, patients rate its staff 3 of 5.
Source:

CMS, Dialysis Facility - Listing by Facility and Patient survey (ICH CAHPS) - Facility. Released Jul 15, 2026. Updated quarterly.

Who owns it?

  • Part of the Fresenius Medical Care chain, as CMS lists it.
  • CMS publishes no owners file for dialysis facilities, so no other owner is named.
Source:

CMS, Dialysis Facility - Listing by Facility. Released Jul 15, 2026. Updated quarterly.

How do patients fare?

  • CMS rates it 3 of 5 stars (Jan 1, 2021 to Dec 31, 2024).
  • Compared by CMS with what it expects for the facility’s patients: patient survival, as expected; hospital admissions, as expected; readmissions to hospital, as expected; blood transfusions, worse than expected; emergency department visits, as expected; emergency department visits within 30 days of a hospital stay, as expected; bloodstream infections, better than expected; patients dialysing through a fistula, as expected; patients put on a kidney transplant waitlist in their first year of dialysis, as expected; patients on a kidney transplant waitlist, as expected.
  • Patients rate it 3 of 5 in CMS’s survey of in-center hemodialysis patients (37 interviews, Oct 18, 2024 to Jul 11, 2025): 65% rated the facility 9 or 10 out of 10.
Source:

CMS, Dialysis Facility - Listing by Facility and Patient survey (ICH CAHPS) - Facility. Released Jul 15, 2026. Updated quarterly.

Ratings and measures, as published
MeasureRating
Star ratingCMS’s star rating for dialysis facilities, 1 to 53 of 5
Patient survey ratingCMS star rating from its survey of the facility’s in-center hemodialysis patients (ICH CAHPS), 1 to 53 of 5

How does it compare nearby?

  • Of the 3 dialysis facilities CMS lists in Maury County, 3 have a star rating from CMS: 1 rated 5 of 5, 2 rated 3 of 5.
  • CMS rates this one 3 of 5.
Source:

CMS, Dialysis Facility - Listing by Facility. Released Jul 15, 2026. Updated quarterly.

2 compared
PlaceStar rating
Davita Columbia Dialysis3
Fkc Spring Hill TN5

What the record doesn’t say

  • CMS doesn’t publish fines or other penalties for dialysis facilities, so none are shown.
  • Only complaints that led to a citation appear; complaints that didn’t aren’t published.
  • QCOR says it has no dialysis inspection reports after February 19, 2026, while it moves to a new system: a later inspection is not shown yet.
  • CMS doesn’t publish staffing levels for dialysis facilities.
  • CMS publishes no owners file for dialysis facilities: the chain it lists is the only owner named.

Sources

If you believe something here is wrong, a correction starts with the agency whose record this copies: CMS. CMS’s own record is on Care Compare. If Hearth Record copied something wrongly, it will fix it and log the correction publicly, with its date: how corrections work.

Source:

This copy of the record was made on Oct 30, 2026.

From the facility

The public record above comes first. Anything the facility adds will appear here, below it, and say who wrote it.

Replies

None. Replies aren’t open yet. When they open, the facility will be able to answer any finding for free, and the reply will show beside that finding, unedited and dated.

Paid listing

None. Paid listings aren’t open yet. When they open, anything paid for will say “Paid by the facility”, and paying will never change a finding, a rating or the order of results.

How to read a record

Four things every record does, shown on an example record made up for this guide.

An example record, made up for this guide

An example nursing home

Made up for this guide: no real place is shown

Not fully inspected in over two years (CMS flag)

11 health citations at the latest inspection cycle

The state average is 14.3.

Source:

CMS, State and US Averages and Health Deficiencies. Released Oct 8, 2026. Updated monthly.

From the homeNone yet. Replies and paid listings aren’t open, and when they open they will sit here, below the record.

1 of 4

Every fact names its source.

Who published it, when, and how often it changes sit beside each fact, with a link to the agency’s own file.

Sign in

A free account keeps your watch list, shortlists, comparisons and saved searches on every device, and can email you when something you watch changes. Browsing never needs one.