Hearth Record

Dci Brownsville

A dialysis facility in Brownsville, Tennessee 38012

378 N. Dupree St., Brownsville, Tennessee 38012. (731) 772-2151.

CMS’s own record, on Care Compare

Watch and the shortlist are kept with a free account, on every device. Your watch list. CMS’s own record is on Care Compare.

The short answer

Record last released by CMS on Oct 28, 2026. We couldn’t read Centers for Medicare & Medicaid Services’ list since Nov 2, 2026: qcor.cms.gov now refuses our reader. This record is as of then.

The last 24 months 6 deficiencies in 1 month of the last 36. Last cited Jan 2025. Most serious: Standard-level. Every month

Each figure’s source sits beside it, in its section below.

What these words mean3
Star ratings
CMS rates some kinds of place from 1 to 5 stars, more stars meaning better on CMS’s own measures for that kind: for a nursing home, its health inspections, staffing and quality measures. A rating is CMS’s summary of those measures; it doesn’t promise good care. Source: CMS, Care Compare and the Five-Star Quality Rating System.
Inspection (survey)
A visit by state inspectors, often unannounced, who check a place against the rules it must meet. For nursing homes and other places Medicare pays, CMS calls these visits surveys: a standard survey of a nursing home comes at least every 15 months, and a complaint survey whenever a complaint calls for one. Source: CMS; 42 CFR 488.308.
Deficiency, citation, violation
What inspectors write up when a place didn’t meet a rule: the rule, what they saw, and when. CMS calls it a deficiency; states may say citation or violation. It is the inspectors’ finding, not a court’s, and the place is usually asked for a plan to correct it. Source: CMS, statement of deficiencies (Form CMS-2567); each state’s licensing agency.

What did inspectors find?

The last inspection on record was on Jan 8, 2025: a standard inspection.

6 deficiencies cited in the last three years.

Source:

CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.

When those deficiencies happened

6 deficiencies in 1 month of the last 36. Last cited Jan 2025. Most serious: Standard-level. The last 3 years, to Oct 30, 2026.

6 deficiencies by month over the last 3 years. Each cell is one month.
JanFebMarAprMayJunJulAugSepOctNovDec
2023 NovDec
2024 JanFebMarAprMayJunJulAugSepOctNovDec
2025 JanFebMarAprMayJunJulAugSepOctNovDec
2026 JanFebMarAprMayJunJulAugSepOct

Hover or focus a month to read it.

No visit on record Visited, nothing cited A stronger orange is more serious, on its source’s own levels, read onto four bands: from the least serious it publishes to the most
Source:

Hearth Record drew this from the dates and levels in the source’s own records.

Each deficiency, as cited

Rule titles as CMS’s inspectors cite them, set in sentence case.

Source:

CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.

Jan 8, 2025: standard inspection6 deficiencies
  • Ic - Wear Gloves/Hand Hygiene

    The inspectors’ words, 220 words

    “IC-WEAR GLOVES/HAND HYGIENE CFR(s): 494.30(a)(1) Wear disposable gloves when caring for the patient or touching the patient’s equipment at the dialysis station. Staff must remove gloves and wash hands between each patient or station. This Standard is not met as evidenced by: 19001 Based on policy review, observation and interview, the facility failed to ensure hand hygiene was performed during the termination of dialysis treatments for a patient with a CVC access for 1 of 2 (RN #1) observations. The findings included: 1. Review of the facility policy “Hand Antisepsis” issued August 2014, revealed, “...Hand antisepsis will be followed per CDC guidelines...Use of an alcohol-based hand rub may be done in the following instances: After handling of equipment, supplies or environmental surfaces at the patient station, Before patient contact...” 2. Observations on 1/6/2025 at 3:05 PM, at Station #2, revealed RN #1 terminated treatment for RP #1. RN #1, with clean gloved hands, reinfused the extracorporeal circuit and touched the dialysis machine. RN #1 then cleaned the CVC connections with alcohol. RN #1 did not perform hand hygiene after touching the dialysis machine. 3. During an interview on 1/7/2025 at 8:01 AM, the NM verified staff should remove gloves, perform hand hygiene, and don clean gloves after touching a dialysis machine and before providing care to RP #1’s CVC access.”

    Rule V0113. Standard-level.

  • Ic - Clean/Dirty Areas, Med Prep Area, No Common Med Carts

    The inspectors’ words, 301 words

    “IC-CLEAN/DIRTY;MED PREP AREA;NO COMMON CARTS CFR(s): 494.30(a)(1)(i) Clean areas should be clearly designated for the preparation, handling and storage of medications and unused supplies and equipment. Clean areas should be clearly separated from contaminated areas where used supplies and equipment are handled. Do not handle and store medications or clean supplies in the same or an adjacent area to that where used equipment or blood samples are handled. When multiple dose medication vials are used (including vials containing diluents), prepare individual patient doses in a clean (centralized) area away from dialysis stations and deliver separately to each patient. Do not carry multiple dose medication vials from station to station. Do not use common medication carts to deliver medications to patients. If trays are used to deliver medications to individual patients, they must be cleaned between patients. This Standard is not met as evidenced by: 19001 Based on observation and interview the facility failed to ensure staff disposed of fluids from prime waste container into a dirty sink for 1 of 2 (RN #1) observations during cleaning of the dialysis machine. The findings included: 1. Observations on 1/6/2025 beginning at 9:23 AM revealed RN #1 cleaned the dialysis machine at Station #2. RN #1 removed the prime waste container and disposed of the prime fluids in the designated clean sink. 2. During an interview on 1/6/2025 at 11:35 AM, the Nurse Educator stated there was no specific policy to address where staff should dispose of the prime waste. The Nurse Educator verified the prime fluids should be taken to a dirty sink instead of a clean sink when cleaning and disinfecting the dialysis machine. 3. During an interview on 1/7/2025 at 11:34 AM, the NM verified the expectation was for staff to dispose of the prime container fluids into the dirty sink.”

    Rule V0117. Standard-level.

  • Ic - Aseptic Techniques For Iv Meds

    The inspectors’ words, 192 words

    “IC-ASEPTIC TECHNIQUES FOR IV MEDS CFR(s): 494.30(b)(2) [The facility must-] (2) Ensure that clinical staff demonstrate compliance with current aseptic techniques when dispensing and administering intravenous medications from vials and ampules; and This Standard is not met as evidenced by: 19001 Based on observation and interview, the facility failed to dispose of expired medication for 1 of 2 (medication refrigerator) medication storage areas. The findings included: 1. Observations of the medication refrigerator on 1/7/2025 at 1:16 PM revealed the following items were expired: Retacrit (erythropoiesis-stimulating agent (ESA), which is a prescription medicine used to treat anemia) 20,000 units/2 mL 9 vials expired on 12/31/2024. 2. During an interview on 1/7/2025 at 1:17 PM, the NM verified the medication should have been disposed. The surveyor requested the facility policy for disposing of expired medications. During an interview on 1/7/2025 at 1:37 PM, the NM stated she was unable to locate a policy for expired medication disposal. The NM further stated nurses were required to check it at the end of every month for expired medications. The NM stated nursing staff were also required to check a medication for the expiration date before administration.”

    Rule V0143. Standard-level.

  • Ic - Staff Education Re Catheters/Catheter Care

    The inspectors’ words, 384 words

    “IC-STAFF EDUCATION-CATHETERS/CATHETER CARE CFR(s): 494.30(a)(2) Recommendations for Placement of Intravascular Catheters in Adults and Children I. Health care worker education and training A. Educate health-care workers regarding the ... appropriate infection control measures to prevent intravascular catheter-related infections. B. Assess knowledge of and adherence to guidelines periodically for all persons who manage intravascular catheters. II. Surveillance A. Monitor the catheter sites visually of individual patients. If patients have tenderness at the insertion site, fever without obvious source, or other manifestations suggesting local or BSI [blood stream infection], the dressing should be removed to allow thorough examination of the site. Central Venous Catheters, Including PICCs, Hemodialysis, and Pulmonary Artery Catheters in Adult and Pediatric Patients. VI. Catheter and catheter-site care B. Antibiotic lock solutions: Do not routinely use antibiotic lock solutions to prevent CRBSI [catheter related blood stream infections]. This Standard is not met as evidenced by: 19001 Based on facility policy review, observation, and interview the facility failed to ensure CVC exit site care was performed according to policy for 2 of 2 (RN #1 and LPN #1) staff observed performing CVC care. The findings included: 1. Review of the facility policy “Central Venous Catheter Exit Site Care” issued June 2009, revealed, “... Place pre-printed label over dressing. This label should state the concentration and amount of Heparin instilled in each catheter lumen along with the date and initials of nurse changing the bandage ...” 2. Observations on 01/06/2025 of 2 of 2 patients receiving CVC Exit Site Care revealed the following: a. RP #1 received CVC Exit Site Care by RN #1 at 10:35 AM at Station #2. RN #1 did not place a label over the dressing at the end of site care. b. Patient #5 received CVC Exit Site Care by LPN #1 at 11:20 AM at Station #11. LPN #1 did not place a label over the dressing at the end of site care. 3. During an interview on 01/07/2025 at 9:15 AM with the NM, she stated there was an expectation that staff place a label on the CVC dressing every time the dressing was changed. The NM confirmed there are pre-printed labels available for staff use, and that occasionally a patient would refuse the label; however, that should be documented in the chart if that was the case.”

    Rule V0147. Standard-level.

  • Carbon Adsorption - Two Tanks/Sample Ports

    The inspectors’ words, 498 words

    “CARBON ADSORPTION-TWO TANKS/SAMPLE PORTS CFR(s): 494.40(a) 5.2.5 Carbon adsorption: two tanks/sample ports Refer to RD62:2001, 4.3.9 Carbon adsorption media: Carbon adsorption systems shall be adapted specifically to the maximum anticipated water flow rate of the system. Two carbon adsorption beds shall be installed in a series configuration. 5.2.5 Carbon adsorption Two carbon beds shall be installed in series with a sample port following the first bed. A sample port shall also be installed following the second bed for use in the event of free chlorine or chloramine breaking through the first bed. This Standard is not met as evidenced by: 19001 Based on policy review, observation and interview, the facility failed to ensure 2 of 3 (RN #1 and CCHT#1) staff observed were competent in total chlorine testing for RO water to ensure patient safety. The findings included: 1. Review of the facility policy “R.O.Water Testing” issued 11/15/2023 revealed, “Purpose: To provide AAMI quality of water for hemodialysis...Total chlorine testing will be performed on the water after the first carbon tank at sample port S4...Procedure...Collect a fresh 100 ml sample of RO water in a plastic sample cup at S4. Remove the test strip from its foil package...Using timer for 60 seconds: dip the test strip in the water sample. Moving test strip back and forth at a constant rate...Remove the test strip after 60 seconds. Briskly shake the test strip once to remove excess water. Using the timer wait 20 seconds for the test strip to develop...After the 20 second wait period, immediately compare the test strip color to the color chart to determine total chlorine level of the sample...” 2. Observations on 1/6/2024 at 12:15 PM revealed RN #1 rinsed the sample cup three times with RO water, filled the cup to 90 mL, then swirled the test strip for 20 seconds. RN #1 then removed the test strip, shook the test strip to remove excess water and waited 60 seconds to read/ compare the test strip to the color chart to determine the total chlorine results. RN #1 did not follow the facility protocols for water testing. Observations on 1/6/2025 beginning at 3:15 PM revealed CCHT #1 rinsed the sample cup three times with water just past the water softener tank, filled the sample cup with 90 mL of water from the area used to check water hardness, not the S4 first carbon tank sample port. CCHT #1 then swirled the test strip for 1 minute and 20 seconds. CCHT #1 then removed the test strip, shook the excess water, and compared the strip to the color chart to determine the total chlorine results. CCHT #1 did not follow the facility protocols for water testing. 3. During an interview on 1/6/2025 at 3:50 PM, the Nurse Educator stated all clinical staff were trained upon hire and annually to determine competence for water testing. Personnel file review revealed both RN #1 and CCHT #1 had been trained in 2024 on the facility policy for water testing.”

    Rule V0192. Standard-level.

  • Achieve Adequate Clearance

    The inspectors’ words, 3,215 words

    “POC-ACHIEVE ADEQUATE CLEARANCE CFR(s): 494.90(a)(1) Achieve and sustain the prescribed dose of dialysis to meet a hemodialysis Kt/V of at least 1.2 and a peritoneal dialysis weekly Kt/V of at least 1.7 or meet an alternative equivalent professionally-accepted clinical practice standard for adequacy of dialysis. This Standard is not met as evidenced by: 19001 Based on policy review, medical record review and interview, the facility failed to ensure 5 of 5 (Patient #1, 2, 3, 4 and 5) sampled patients received the prescribed dialysis prescription for BFR and/or Heparin. The facility also failed to notify the physician of changes to the dialysis prescriptions. The findings included: 1. Review of the facility policy “Heparin” issued January 2019, revealed... “Administer dose per standing orders or by specific patient order per MD...” 2. Medical record review for Patient #1 revealed an admission date of 06/19/2024 with diagnoses which included Hypertensive Chronic Kidney Disease. A physician’s order dated 05/29/2024 revealed dialysis 3 times per week with a BFR of 400. A physician’s order dated 10/23/2024 revealed an hourly dose of IV Heparin 1000 units for 3 hours and 30 minutes during dialysis. Review of the 12/04/2024 Hemodialysis Flowsheet revealed the BFR was 350 from 6:54 AM to 8:05 AM and 300 from 8:05 AM until the treatment ended at 10:25 AM. The nurse documented 2500 units of Heparin was infused during the treatment. There was no documentation that revealed why the BFR was not delivered at the ordered rate of 400, or why 3500 units of Heparin was not infused. There was no documentation the physician was notified of the BFR not being administered at the prescribed rate or the failure to administer Heparin as ordered. Review of the 12/06/2024 Hemodialysis Flowsheet revealed the BFR was 300 from 8:06 AM to 10:05 AM and 200 from 10:35 AM until the treatment ended at 10:37 AM. The nurse documented 2500 units of Heparin was infused during the treatment. There was no documentation that revealed why the BFR was not delivered at the ordered rate of 400, or why 3500 units of Heparin was not infused. There was no documentation the physician was notified of the BFR not being administered at the prescribed rate or the failure to administer Heparin as ordered. Review of the 12/09/2024 Hemodialysis Flowsheet revealed the BFR was 300 from 9:31 AM to 12:42 PM and 200 from 12:42 PM until the treatment ended at 12:43 PM. At 10:37 AM, a note documented the BFR was decreased to 300 due to multiple alarms; however, no further documentation was found to explain the decrease from 300 to 200. RN #1 documented 2500 units of Heparin was infused during the treatment. There was no documentation that revealed why 3500 units of Heparin was not infused and no documentation that the physician was notified of the BFR not being administered at the prescribed rate or the failure to administer Heparin as ordered. Review of the 12/11/2024 Hemodialysis Flowsheet revealed the BFR was 350 from 6:54 AM to 8:05 AM and 300 from 8:05 AM until the treatment ended at 10:25 AM. At 8:06 AM, a note documented by RN #1 revealed the BFR was decreased to 350 due to arterial alarms; however, there was no further documentation that revealed why the BFR was not delivered at the ordered rate or that the physician was notified of the BFR not being administered at the prescribed rate. Review of the 12/13/2024 Hemodialysis Flowsheet revealed no documented Heparin administration of 1000 units per hour. There was no documentation the physician was notified of the failure to administer Heparin as ordered. Review of the 12/16/2024 Hemodialysis Flowsheet revealed the BFR was 350 from 7:02 AM to 8:01 AM; 300 from 8:01 AM to 10:31 AM and 200 from 10:31 AM until the treatment ended at 10:51 AM. At 8:14 AM, a note documented the BFR was decreased to 300 due to multiple alarms and that the Charge Nurse was notified. The nurse documented 2500 units of Heparin was infused during the treatment. There was no documentation that revealed why 3500 units of Heparin was not infused, and no further documentation that revealed why the BFR was not delivered at the ordered rate of 400. There was no documentation the physician was notified of the BFR not being administered at the prescribed rate or the failure to administer Heparin as ordered. Review of the 12/18/2024 Hemodialysis Flowsheet revealed the BFR was 300 from 7:31 AM to 10:01 AM and 200 from 10:01 AM until the treatment ended at 11:05 AM. At 7:43 AM a note documented the BFR was decreased to 300 due to multiple alarms. There was no further documentation that revealed why the BFR was not delivered at the ordered rate of 400 and changed to 200. The nurse documented 2500 units of Heparin was infused during the treatment. There was no documentation that revealed why 3500 units of Heparin was not infused and no documentation that the physician was notified of the BFR not being administered at the prescribed rate or the failure to administer Heparin as ordered. Review of the 12/20/2024 Hemodialysis Flowsheet revealed the BFR was 350 from 6:22 AM to 7:01 AM; 300 from 7:01 AM to 7:31 AM and 200 from 7:31 AM until the treatment ended at 10:00 AM. At 7:31 AM, a note documented the BFR was decreased to 200 and that the CN was notified; however, there was no documentation that revealed why the BFR was not delivered at the ordered rate of 400 and changed to 200 or that the charge nurse was notified of the change from 350 to 300. Review of the 12/27/2024 Hemodialysis Flowsheet revealed the BFR was 300 from 7:00 AM to 9:00 AM; 200 from 9:00 AM to 09:33 AM and 300 from 9:33 AM until the treatment ended at 10:24 AM. At 7:00 AM, a note documented by RN #1 revealed the BFR was lowered to 300 due to elevated arterial pressure; however, there was no documentation that revealed why the BFR was not delivered at the ordered rate of 400 and changed from 300 to 200 and then from 200 to 300 or that the physician was notified of the changes. Review of the 12/30/2024 Hemodialysis Flowsheet revealed the BFR was 200 from 6:09 AM to 6:30 AM; 350 from 6:30 AM to 8:00 AM; 300 from 8:00 AM to 9:30 AM and 200 from 9:30 AM until the treatment ended at 10:00 AM. At 8:14 AM, a note documented the BFR was decreased due to multiple alarms. There was no further documentation that revealed why the BFR continued to not be delivered at the ordered rate of 400. There was no documented Heparin administration of 1000 units per hour. There was no documentation the physician had been notified of the BFR not being administered at the ordered rate, or the failure to administer Heparin as ordered. Review of the 01/01/2025 Hemodialysis Flowsheet revealed the BFR was 300 from 7:00 AM to 9:00 AM and 200 from 9:00 AM until the treatment ended at 9:42 AM. At 7:16 AM, a note documented the BFR was decreased to 300 due to multiple alarms. There was no further documentation that revealed why the BFR continued to not be delivered at the ordered rate of 400. There was no documented Heparin administration of 1000 units per hour. There was no documentation the physician had been notified of the BFR not being administered at the ordered rate, or the failure to administer Heparin as ordered. 3. Medical record for Patient #2 revealed an admission date of 10/9/2024 with diagnoses which included Hypertension and Unspecified Renal Failure. A physician’s order dated 11/18/2024 revealed dialysis 3 times per week with a BFR of 500. A physician’s order dated 10/07/2024 revealed an hourly dose of Heparin 2000 units for 3 hours and 30 minutes during dialysis. Review of the 10/16/2024 Hemodialysis flowsheet revealed there was no documented Heparin administration of 2000 units per hour. There was no documentation stating why 6500 units of Heparin was not infused. There was no documentation the physician was notified of the failure to administer Heparin as ordered. Review of the 10/21/2024 Hemodialysis flowsheet revealed the BFR was 450 from 8:35 AM PM until the treatment ended at 11:16 AM. There was no documented Heparin administration of 2000 units per hour. There was no documentation stating why the BFR was not delivered at the ordered rate of 500, or why the Heparin was not administered as ordered. There was no documentation the physician was notified of the change in the BFR or the failure to administer Heparin as ordered. Review of the 10/23/2024 Hemodialysis flowsheet revealed there was no documented Heparin administration of 2000 units per hour. There was no documentation stating why 6500 units of Heparin was not infused. There was no documentation the physician was notified of the failure to administer Heparin as ordered. Review of the 10/25/2024 Hemodialysis flowsheet revealed there was no documented Heparin administration of 2000 units per hour. There was no documentation stating why 6500 units of Heparin was not infused. There was no documentation the physician was notified of the failure to administer Heparin as ordered. Review of the 10/28/2024 Hemodialysis flowsheet revealed there was no documented Heparin administration of 2000 units per hour. There was no documentation stating why 6500 units of Heparin was not infused. There was no documentation the physician was notified of the failure to administer Heparin as ordered. Review of the 10/30/2024 Hemodialysis flowsheet revealed there was no documented Heparin administration of 2000 units per hour. There was no documentation stating why 6500 units of Heparin was not infused. There was no documentation the physician was notified of the failure to administer Heparin as ordered. Review of the 11/1/2024 Hemodialysis flowsheet revealed there was no documented Heparin administration of 2000 units per hour. There was no documentation stating why 6500 units of Heparin was not infused. There was no documentation the physician was notified of the failure to administer Heparin as ordered. Review of the 11/4/2024 Hemodialysis flowsheet revealed there was no documented Heparin administration of 2000 units per hour. There was no documentation stating why 6500 units of Heparin was not infused. There was no documentation the physician was notified of the failure to administer Heparin as ordered. Review of the 11/6/2024 Hemodialysis flowsheet revealed the BFR was 300 from 8:01 AM PM until 8:31 AM, and was 400 from 8:31 AM until the treatment ended at 11:08 AM. There was no documented Heparin administration of 2000 units per hour. There was no documentation stating why the BFR was not delivered at the ordered rate of 500, or why the Heparin was not administered as ordered. There was no documentation the physician was notified of the change in the BFR or the failure to administer Heparin as ordered. Review of the 11/8/2024 Hemodialysis flowsheet revealed there was no documented Heparin administration of 2000 units per hour. There was no documentation stating why 6500 units of Heparin was not infused. There was no documentation the physician was notified of the failure to administer Heparin as ordered. Review of the 11/11/2024 Hemodialysis flowsheet revealed there was no documented Heparin administration of 2000 units per hour. There was no documentation stating why 6500 units of Heparin was not infused. There was no documentation the physician was notified of the failure to administer Heparin as ordered. 4. Medical record review for Patient #3 revealed an admission date of 11/27/2024 with diagnoses which included Acute Kidney Failure. A physician’s order dated 11/22/2024 revealed dialysis 3 times per week with a BFR of 350. Review of the 12/6/2024 Hemodialysis Flowsheet revealed the BFR was 400 from 10:31 AM until 11:05 AM. There was no documentation stating why the BFR was not delivered at the ordered rate of 350. There was no documentation the physician was notified. Review of the 12/9/2024 Hemodialysis Flowsheet revealed the BFR was 400 from 11:09 AM until 12:02 PM. There was no documentation stating why the BFR was not delivered at the ordered rate of 350. There was no documentation the physician was notified. Review of the 12/16/2024 Hemodialysis Flowsheet revealed the BFR was 395 from 11:01 AM until 12:01 PM and 400 from 12:02 PM until 1:00 PM. There was no documentation why the BFR was not delivered at the ordered rate of 350. There was no documentation the physician was notified. Review of the 12/23/2024 Hemodialysis Flowsheet revealed the BFR was 200 from 12:45 PM until 1:30 PM and 300 from 1:31 PM until 2:08 PM. There was no documentation stating why the BFR was not delivered at the ordered rate of 350. There was no documentation the physician was notified. Review of the 1/3/2025 Hemodialysis Flowsheet revealed the BFR was 400 from 11:32 AM until 12:01 PM and 200 from 1:02 PM until 1:31 PM. There was no documentation stating why the BFR was not delivered at the ordered rate of 350. There was no documentation the physician was notified. 5. Medical record review for Patient #4 revealed an admission date of 8/23/2024 with diagnoses that included ESRD. A physician’s order dated 8/23/2024 revealed dialysis 3 times per week with a BFR of 350. A physician’s order dated 10/18/2024 revealed an hourly dose of Heparin 1000 units for 4 hours during dialysis. Review of the 12/6/2024 Hemodialysis flowsheet revealed the BFR was 300 from 1:31 PM until the treatment ended at 3:01 PM. There was no documented Heparin administration of 1000 units per hour. There was no documentation stating why the BFR was not delivered at the ordered rate of 350. There was no documentation the physician was notified of the change in the BFR or the failure to administer Heparin as ordered. Review of the 12/9/2024 Hemodialysis flowsheet revealed the BFR was 300 from 2:02 PM until the treatment ended at 3:18 PM. The nurse documented 3000 units of Heparin was infused during the treatment. There was no documentation stating why the BFR was not delivered at the ordered rate of 350, or why 4000 units of Heparin was not infused. There was no documentation the physician was notified of the change in the BFR or the failure to administer Heparin as ordered. Review of the 12/11/2024 Hemodialysis flowsheet revealed the BFR was 400 from 11:12 AM until 12:32 PM, and was 300 from 1:32 PM until the treatment ended at 3:17 PM. The nurse documented 3000 units of Heparin was infused during the treatment. There was no documentation stating why the BFR was not delivered at the ordered rate of 350, or why 4000 units of Heparin was not infused. There was no documentation the physician was notified of the change in the BFR or the failure to administer Heparin as ordered. Review of the 12/13/2024 Hemodialysis flowsheet revealed the BFR was 300 from 12:02 PM until the treatment ended at 3:20 PM. There was no documented hourly Heparin administration of 1000 units per hour. There was no documentation stating why the BFR was not delivered at the ordered rate of 350. There was no documentation the physician was notified of the change in the BFR or the failure to administer Heparin as ordered. Review of the 12/16/2024 Hemodialysis flowsheet revealed there was no documented hourly Heparin administration of 1000 units per hour. There was no documentation stating why 4000 units of Heparin was not infused. There was no documentation the physician was notified of the failure to administer Heparin as ordered. Review of the 12/18/2024 Hemodialysis flowsheet revealed the BFR was 250 from 12:02 PM until the treatment ended at 3:25 PM. There was no documented Heparin administration of 1000 units per hour. There was no documentation stating why the BFR was not delivered at the ordered rate of 350, or why 4000 units of Heparin was not infused. There was no documentation the physician was notified of the change in the BFR or the failure to administer Heparin as ordered. Review of the 12/26/2024 Hemodialysis flowsheet revealed the BFR was 400 from 8:49 AM until 12:04 PM. There was no documented Heparin administration of 1000 units per hour. There was no documentation stating why the BFR was not delivered at the ordered rate of 350, or why 4000 units of Heparin was not infused. There was no documentation the physician was notified of the change in the BFR or the failure to administer Heparin as ordered. Review of the 12/27/2024 Hemodialysis flowsheet revealed the BFR was 400 from 11:18 AM until the treatment ended at 3:22 PM. There was no documentation stating why the BFR was not delivered at the ordered rate of 350. There was no documentation the physician was notified of the change in the BFR. 6. Medical record review for Patient #5 revealed an admission date of 04/08/2022 with diagnoses that included ESRD. A physician’s order dated 05/29/2024 revealed dialysis 3 times per week with a BFR of 350. A physician’s order dated 05/06/2024 revealed a Heparin IV loading dose of 5000 units. Review of the 12/09/2024 Hemodialysis Flowsheet revealed the BFR was 450 from 9:50 AM to 11:31 AM and 200 from 11:31 AM until the treatment ended at 11:45 AM. There was no documentation the physician was notified of the BFR not being administered at the prescribed rate. Review of the 12/16/2024 Hemodialysis Flowsheet revealed no documented Heparin loading dose administration of 5000 units. There was no documentation the physician was notified of the failure to administer Heparin as ordered. Review of the 12/18/2024 Hemodialysis Flowsheet revealed the BFR was 405 from 10:32 AM to 12:02 PM and 200 from 12:03 PM until the treatment ended at 12:04 PM. There was no documentation the physician was notified of the BFR not being administered at the prescribed rate. Review of the 01/03/2025 Hemodialysis Flowsheet revealed the BFR was 400 from 9:43 AM to 12:44 PM and 195 from 12:44 PM until the treatment ended at 12:45 PM. There was no documentation the physician was notified of the BFR not being administered at the prescribed rate. Review of the 01/06/2025 Hemodialysis Flowsheet revealed the BFR was 315 from 11:26 AM to 11:32 AM; 350 from 11:32 AM to 12:04 PM; 200 from 12:04 PM to 1:02 PM; 350 from 1:02 PM to 1:03 PM and 200 from 1:03 PM until the treatment ended at 1:04 PM. There was no documentation the physician was notified of the BFR not being administered at the prescribed rate. 7. During an interview on 1/7/2025 at 9:00 AM, the NM stated the Heparin infusion had to be manually entered by the nurses on the dialysis flowsheets. The NM stated an internal audit had identified the nursing staff were not correctly documenting the hourly infusion of Heparin. The NM stated the hourly infusion was programmed into the machine and delivered correctly, but staff were failing to manually enter the infusion amounts on the dialysis flowsheets. During an interview on 1/7/2025 at 2:09 PM, the NM stated she was unable to locate a policy related to BFR. The NM stated if the BFR was adjusted during dialysis the staff should notify the charge nurse and document why the adjustment was made on the dialysis flowsheets.”

    Rule V0544. Standard-level.

The one inspection in the last three years
Inspections on record
DateVisitWhat the record says
Jan 8, 2025Standard inspection6 deficiencies cited

Is it certified?

  • Medicare-certified dialysis facility, certified or last recertified on Feb 28, 1987.
  • Run as a non-profit.
  • No deficiency on record in the last three years.
  • Chain: Dialysis Clinic, Inc.
Source:

CMS, Dialysis Facility - Listing by Facility. Released Jul 15, 2026. Updated quarterly.

CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.

Has it been penalized?

  • CMS doesn’t publish fines or other penalties for dialysis facilities.
  • None of the deficiencies cited in the last three years came from an inspection that included a complaint investigation.
Source:

CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.

What does it offer?

  • Offers in-center hemodialysis.
  • Doesn’t offer peritoneal dialysis, home hemodialysis training and a shift starting at 5 p.m. or later.
  • 16 dialysis stations.
  • CMS doesn’t publish staffing levels for dialysis facilities.
Source:

CMS, Dialysis Facility - Listing by Facility and Patient survey (ICH CAHPS) - Facility. Released Jul 15, 2026. Updated quarterly.

Who owns it?

  • Part of the Dialysis Clinic, Inc. chain, as CMS lists it.
  • CMS publishes no owners file for dialysis facilities, so no other owner is named.
Source:

CMS, Dialysis Facility - Listing by Facility. Released Jul 15, 2026. Updated quarterly.

How do patients fare?

  • CMS rates it 3 of 5 stars (Jan 1, 2021 to Dec 31, 2024).
  • Compared by CMS with what it expects for the facility’s patients: patient survival, as expected; hospital admissions, as expected; emergency department visits, as expected; emergency department visits within 30 days of a hospital stay, as expected; bloodstream infections, as expected; patients dialysing through a fistula, as expected; patients on a kidney transplant waitlist, worse than expected.
  • CMS gives no : “Too few completed survey responses to report.”
Source:

CMS, Dialysis Facility - Listing by Facility and Patient survey (ICH CAHPS) - Facility. Released Jul 15, 2026. Updated quarterly.

Ratings and measures, as published
MeasureRating
Star ratingCMS’s star rating for dialysis facilities, 1 to 53 of 5
Patient survey ratingCMS star rating from its survey of the facility’s in-center hemodialysis patients (ICH CAHPS), 1 to 5Not rated

How does it compare nearby?

  • Of the 2 dialysis facilities CMS lists in Haywood County, 2 have a star rating from CMS: 2 rated 3 of 5.
  • CMS rates this one 3 of 5.
Source:

CMS, Dialysis Facility - Listing by Facility. Released Jul 15, 2026. Updated quarterly.

1 compared
PlaceStar rating
Davita Brownsville Dialysis3

What the record doesn’t say

  • CMS doesn’t publish fines or other penalties for dialysis facilities, so none are shown.
  • Only complaints that led to a citation appear; complaints that didn’t aren’t published.
  • QCOR says it has no dialysis inspection reports after February 19, 2026, while it moves to a new system: a later inspection is not shown yet.
  • CMS doesn’t publish staffing levels for dialysis facilities.
  • CMS publishes no owners file for dialysis facilities: the chain it lists is the only owner named.

Sources

If you believe something here is wrong, a correction starts with the agency whose record this copies: CMS. CMS’s own record is on Care Compare. If Hearth Record copied something wrongly, it will fix it and log the correction publicly, with its date: how corrections work.

Source:

This copy of the record was made on Oct 30, 2026.

From the facility

The public record above comes first. Anything the facility adds will appear here, below it, and say who wrote it.

Replies

None. Replies aren’t open yet. When they open, the facility will be able to answer any finding for free, and the reply will show beside that finding, unedited and dated.

Paid listing

None. Paid listings aren’t open yet. When they open, anything paid for will say “Paid by the facility”, and paying will never change a finding, a rating or the order of results.

How to read a record

Four things every record does, shown on an example record made up for this guide.

An example record, made up for this guide

An example nursing home

Made up for this guide: no real place is shown

Not fully inspected in over two years (CMS flag)

11 health citations at the latest inspection cycle

The state average is 14.3.

Source:

CMS, State and US Averages and Health Deficiencies. Released Oct 28, 2026. Updated monthly.

From the homeNone yet. Replies and paid listings aren’t open, and when they open they will sit here, below the record.

1 of 4

Every fact names its source.

Who published it, when, and how often it changes sit beside each fact, with a link to the agency’s own file.

Sign in

A free account keeps your watch list, shortlists, comparisons and saved searches on every device, and can email you when something you watch changes. Browsing never needs one.