Hearth Record

Davita Cypress Gardens Dialysis

A dialysis facility in Sumter, South Carolina 29150

418 Broad Street, Sumter, South Carolina 29150. (803) 418-5129.

CMS’s own record, on Care Compare

Watch and the shortlist are kept with a free account, on every device. Your watch list. CMS’s own record is on Care Compare.

The short answer

Record last released by CMS on Oct 28, 2026.

The last 24 months 7 deficiencies in 1 month of the last 36. Last cited May 2024. Most serious: Condition-level. Every month

Each figure’s source sits beside it, in its section below.

What these words mean4
Star ratings
CMS rates some kinds of place from 1 to 5 stars, more stars meaning better on CMS’s own measures for that kind: for a nursing home, its health inspections, staffing and quality measures. A rating is CMS’s summary of those measures; it doesn’t promise good care. Source: CMS, Care Compare and the Five-Star Quality Rating System.
Inspection (survey)
A visit by state inspectors, often unannounced, who check a place against the rules it must meet. For nursing homes and other places Medicare pays, CMS calls these visits surveys: a standard survey of a nursing home comes at least every 15 months, and a complaint survey whenever a complaint calls for one. Source: CMS; 42 CFR 488.308.
Deficiency, citation, violation
What inspectors write up when a place didn’t meet a rule: the rule, what they saw, and when. CMS calls it a deficiency; states may say citation or violation. It is the inspectors’ finding, not a court’s, and the place is usually asked for a plan to correct it. Source: CMS, statement of deficiencies (Form CMS-2567); each state’s licensing agency.
Condition-level deficiency
For hospices, home health agencies, hospitals and dialysis facilities, CMS writes deficiencies at two levels. Standard is the usual one; condition-level is the more serious, when a problem is serious enough that the provider doesn’t meet a whole condition of taking part in Medicare. Source: CMS, State Operations Manual.

What did inspectors find?

The last inspection on record was on May 23, 2024: a standard inspection.

7 deficiencies cited in the last three years, 1 of them at condition level, the most serious.

1 deficiency at condition level, the more serious of CMS’s two levels

Source:

CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.

When those deficiencies happened

7 deficiencies in 1 month of the last 36. Last cited May 2024. Most serious: Condition-level. The last 3 years, to Oct 30, 2026.

7 deficiencies by month over the last 3 years. Each cell is one month.
JanFebMarAprMayJunJulAugSepOctNovDec
2023 NovDec
2024 JanFebMarAprMayJunJulAugSepOctNovDec
2025 JanFebMarAprMayJunJulAugSepOctNovDec
2026 JanFebMarAprMayJunJulAugSepOct

Hover or focus a month to read it.

No visit on record Visited, nothing cited A stronger orange is more serious, on its source’s own levels, read onto four bands: from the least serious it publishes to the most
Source:

Hearth Record drew this from the dates and levels in the source’s own records.

Each deficiency, as cited

Rule titles as CMS’s inspectors cite them, set in sentence case.

Source:

CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.

May 23, 2024: standard inspection7 deficiencies
  • Cfc - Water And Dialysate Quality

    The inspectors’ words, 107 words

    “CFC-WATER & DIALYSATE QUALITY CFR(s): 494.40 This Condition is not met as evidenced by: 30011 Based on observation, interview and review of facility policy and procedure, the dialysis facility failed to ensure the testing of the water quality was completed appropriately by knowlegeable staff. The findings include: Cross Reference to V0196: The dialysis facility failed to ensure 3 of 4 staff members performed the total chlorine monitoring for the water system according to manufacturer’s guidelines. Cross Reference to V0197: The dialysis facility failed to ensure 3 of 3 Patient Care Technicians was able to identify the maximum allowable limit for total chlorine in the dialysis quality water.”

    Rule V0175. Condition-level.

  • Ic - Sanitary Environment

    The inspectors’ words, 153 words

    “IC-SANITARY ENVIRONMENT CFR(s): 494.30 The dialysis facility must provide and monitor a sanitary environment to minimize the transmission of infectious agents within and between the unit and any adjacent hospital or other public areas. This Standard is not met as evidenced by: 30011 Based on observation and interview, the dialysis facility failed to ensure the patient medication refrigerator was not located in the dirty laboratory area located beside the nursing station in the facility. The findings include: Observation on 5/20/24 at 9:20 AM of the treatment room floor revealed a patient medication refrigerator located in the lab area next to the lab refrigerator noted with used blood collection tubes. Further observation revealed a clean sink located beside (2) centrifuge machines on the countertop above the patient medication refrigerator. During an interview on 5/23/24 at 3:00 PM, the Facility Administrator stated, “I don’t know why the medication refrigerator is located in the lab area”.”

    Rule V0111. Standard-level.

  • Carbon Adsorption - Monitoring, Testing Frequency

    The inspectors’ words, 695 words

    “CARBON ADSORP-MONITOR, TEST FREQUENCY CFR(s): 494.40(a) 6.2.5 Carbon adsorption: monitoring, testing freq Testing for free chlorine, chloramine, or total chlorine should be performed at the beginning of each treatment day prior to patients initiating treatment and again prior to the beginning of each patient shift. If there are no set patient shifts, testing should be performed approximately every 4 hours. Results of monitoring of free chlorine, chloramine, or total chlorine should be recorded in a log sheet. Testing for free chlorine, chloramine, or total chlorine can be accomplished using the N.N-diethyl-p-phenylene-diamine (DPD) based test kits or dip-and-read test strips. On-line monitors can be used to measure chloramine concentrations. Whichever test system is used, it must have sufficient sensitivity and specificity to resolve the maximum levels described in [AAMI] 4.1.1 (Table 1) [which is a maximum level of 0.1 mg/L]. Samples should be drawn when the system has been operating for at least 15 minutes. The analysis should be performed on-site, since chloramine levels will decrease if the sample is not assayed promptly. This Standard is not met as evidenced by: 30011 Based on observations, interviews, and review of manufacturer’s guidelines, the dialysis facility failed to ensure 3 of 4 staff members performed the total chlorine monitoring for the water system according to the manufacturer’s instructions for use. (Patient Care Technicians (PCT) #1, #2 and #3). The findings include: Review of manufacturer’s guidelines entitled, “Ultra-Low Total Chlorine Test Strips” on 5/22/24 at 12:45 PM revealed, “1) Collect a fresh 100 ml (milliter) sample of water in clean plastic sample cup...2) Remove one test strip from its foil package and swish it in the sample for the amount of time indicated according to the following temperatures ranges...3) Remove the strip and shake once, briskly, to removes excess water. 4) Wait 20 seconds for the test strip color to develop. While waiting, fold the white plastic handle of the test strip under the reagent area aperture so that it provides a consistent viewing background. 5) After the 20 second wait period, immediately compare the strip color to the...color chart to determine the Total Chlorine level in the sample...”. Observation of the chlorine water check on 5/22/24 at 11:58 AM to 11:59 AM revealed PCT #1 along with observation by PCT #2 obtained a 100 ml sample of water from post primary carbon tank port. PCT #1 opened a total chlorine test strip, placed it in the water sample and swished it for 30 seconds. Post swishing of the test strip, PCT #1 immediately folded the strip in half and read the strip based on the color chart and stated the result was 0.00. PCT #1 failed to swish the strip in the water for 60 seconds then wait 20 seconds prior to reading the test strip. During an interview on 5/22/24 at 11:59 AM, PCT #1 stated, “We only swish the strip for 30 seconds and then we immediately read the strip”. During an interview at 12:00 PM, PCT #2 who observed stated, “I agree with the way he/she performed the test. That’s the way we do it”. Observation of the chlorine water check on 5/22/24 at 12:14 PM to 12:16 PM revealed PCT #3 along with observation by Registered Nurse (RN) #1 obtained over 100 ml sample of water from post primary carbon tank port. PCT #3 opened a total chlorine test strip, placed it in the water sample and swished it for 30 seconds. Post swishing of the strip, PCT #3 removed the test strip and immediately began to read the strip when RN #1 stated, “The strip should have been swished for 60 seconds”. RN #1 proceeded to open another test strip and perform the test. RN #1 swished the strip for 60 seconds, placed the strip together and then immediately read the results based on the color chart as 0.00. During an interview on 5/22/24 at 12:18 PM, RN #1 stated, “We are to swish the strip for 60 seconds”. During an interview on 5/22/24 at 12:18 PM, PCT #3 stated, “I wasn’t really looking at the clock when I was doing it and we didn’t wait for 20 seconds before reading the strip”.”

    Rule V0196. Standard-level.

  • Carbon Adsorption - Action If First Test Positive

    The inspectors’ words, 445 words

    “CARBON ADSORP-ACTION IF FIRST TEST + CFR(s): 494.40(a) 5.2.5 Carbon adsorption: action if first test positive When samples from the first sampling port are positive for chlorine or chloramine, operation may be continued for a short time (up to 72 hours) until a replacement bed is installed, provided that samples from the second sampling port remain negative. The replacement bed should be placed in the second position, and the existing second bed should be moved to the first position to replace the exhausted bed. If it is not possible to rotate the position of the beds, both beds should be replaced. This Standard is not met as evidenced by: 30011 Based on observations, interviews, and review of facility policy and procedures, the dialysis facility failed to ensure 3 of 3 Patient Care Technicians was able to state the maximum allowable limit for total chlorine in dialysis quality water. (PCT #1, #2 and #3). The findings include: Observation on 5/22/24 at 11:58 AM to 11:59 AM of the chlorine water testing revealed PCT #1 performed the chlorine testing of the water and PCT #2 observed during the process. When asked the maximum allowable limits for the chlorine water testing, PCT #1 stated, “I really don’t know but I thing the maximum allowable limit is greater than 0.01. Anything more than 0.01 we will recheck the water and if its high then we check at the post carbon port past the secondary carbon tank. PCT #2 stated, “What PCT #1 stated is correct and I agree with that”. Observation on 5/22/24 at 12:14 PM to 12:18 PM of the chlorine water testing revealed PCT #3 performed the chlorine water testing and Registered Nurse (RN) #1 observed during the process. When asked the maximum allowable limits for the chlorine water testing, PCT #3 stated, “Greater than 0.01” and RN #1 stated, “0.10 is action level”. Review of personnel files on 5/22/24 at 1:20 PM revealed PCT #1 was deemed competent for “Total Chlorine Testing” on 3/20/24, PCT #2 was deemed competent on 3/20/24 and PCT #3 was deemed competent on 4/19/24. Facility policy, entitled “Daily Water System Total Chlorine Monitoring” revealed, “11. If the results of Total Chlorine testing from the primary carbon filter or set of tanks indicate a level of less than or equal to 0.1 ppm (parts per million) (<-0.1 ppm), Record results on the “Routine Total Chlorine Testing” log...a. If the results of Total Chlorine testing from the primary carbon filter indicate a level of greater than 0.1 ppm (parts per million) (>0.1 ppm), the test should be immediately repeated on a freshly drawn sample to verify the results are not a “false positive...”.”

    Rule V0197. Standard-level.

  • Personnel - Training Program/Periodic Audits

    The inspectors’ words, 450 words

    “PERSONNEL-TRAINING PROGRAM/PERIODIC AUDITS CFR(s): 494.40(a) 9 Personnel: training program/periodic audits A training program that includes quality testing, the risks and hazards of improperly prepared concentrate, and bacterial issues is mandatory. Operators should be trained in the use of the equipment by the manufacturer or should be trained using materials provided by the manufacturer. The training should be specific to the functions performed (i.e., mixing, disinfection, maintenance, and repairs). Periodic audits of the operators’ compliance with procedures should be performed. The user should establish an ongoing training program designed to maintain the operator’s knowledge and skills. This Standard is not met as evidenced by: 30011 Based on observation, interview, review of facility policy and procedure and manufacturer guidelines, the dialysis clinic failed to ensure personnel staff labeled the Minncare disinfectant bottle post disinfection of the continuous water pressure (CWP) reverse osmosis (RO) machine and 1 of 2 Registered Nurses (RN #1) was checked off for competency to perform water testing for chlorine. The findings include: Observation on 5/20/24 at 9:04 AM of the Minncare bottle used to disinfect the CWP RO machine revealed a black mark noted on the bottle last dated 5/10/24. Signage on the CWP RO machine further revealed “Peractic Acid 5/16 at 12:00” with no black mark labeling a disinfection on 5/16/24. During an interview on 5/20/24 at 9:10 AM, the Biomedical Technician stated, “Staff are taught to use the signage to write down when they did the disinfection but also to mark the disinfectant bottle once they finish disinfections”. Facility policy, entitled “CWP Post Chemical Disinfect Start UP” revealed, “12. Mark the level of the disinfectant and the date on the Minncare disinfectant container, and verify that the disinfectant level is lower than the marking from the previous disinfection...”. Review of manufacturer guidelines revealed, “Step 6 Mark the fluid level and the date on the disinfectant container with a permanent marker...”. Review of RN #1’s personnel file on 5/22/24 at 1:20 PM revealed no documentation for total chlorine testing competency. Review of “Routine Total Chlorine Testing Log” revealed RN #1 documented “Verifying Each Test is Documented and Results Appropriate” on 5/17/24 at 12:45 PM and on 5/20/24 at 12:45 PM. During an interview on 5/22/24 at 12:35 PM, RN #1 stated, “I did check the water on Monday (5/20) because they were backed up”. During an interview on 5/22/24 at 12:20 PM, the Biomedical Technician stated, “RN #1 is not signed off yet (to check the water)”. During an interview on 5/22/24 at 1:30 PM, Facility B Clinic Manager stated, “Contract staff coming to the facility go through a check-off with the Biomed prior to doing water checks and RN #1 has not been checked off yet”.”

    Rule V0260. Standard-level.

  • Pe - Safe, Functional, Comfortable Environment

    The inspectors’ words, 206 words

    “PE-SAFE/FUNCTIONAL/COMFORTABLE ENVIRONMENT CFR(s): 494.60 The dialysis facility must be designed, constructed, equipped, and maintained to provide dialysis patients, staff, and the public a safe, functional, and comfortable treatment environment. This Standard is not met as evidenced by: 30011 Based on observations, interviews and review of facility policy and procedure, the dialysis facility failed to ensure expired supplies were removed from the patient care area. The findings include: Observation on 5/20/24 at 9:12 AM of the dialysis facility storage room revealed (250) 17 gauge x (by) 1 1/4 filter needles expired 1/31/22. During an interview on 5/20/24 at 9:15 AM, the Biomedical Technician verified the findings. Observation on 5/20/24 at 9:40 AM of the dialysis treatment room floor revealed (1) bottle of (50) EZ 6.8-8.5 pH test strips expired 4/30/24 . During an interview on 5/20/24 at 10:14 AM, Patient Care Technician (PCT) #4 stated, “Strips are used until the expiration”. Observation on 5/20/24 at 9:45 AM of the dialysis treatment room floor revealed (40) povidone-iodine prep pads expired 12/23. During an interview on 5/20/24 at 9:50 AM, Patient Care Technician (PCT) #3 verified the findings. Facility policy, entitled “Infection Control For Dialysis Facilities” revealed, “b. Expiration date and package integrity will be verified prior to use...”.”

    Rule V0401. Standard-level.

  • Manage Volume Status

    The inspectors’ words, 420 words

    “POC-MANAGE VOLUME STATUS CFR(s): 494.90(a)(1) The plan of care must address, but not be limited to, the following: (1) Dose of dialysis. The interdisciplinary team must provide the necessary care and services to manage the patient’s volume status; This Standard is not met as evidenced by: 30011 Based on record review, interview and review of facility policy and procedure, the dialysis clinic failed to ensure elevated blood pressures for 2 of 4 patient’s during treatment were reported to the physician. The findings include: Record review on 5/23/24 at 9:22 AM of Patient #3’s chart revealed Patient #3 was admitted to the dialysis clinic on 3/13/24 for acute kidney failure. Review of dialysis treatment sheets revealed the following elevated blood pressures (BP) post treatment: 5/01/24: BP 168/102 5/03/24: BP 162/112 5/06/24: BP 158/109 5/13/24: BP 160/100 5/17/24: BP 169/105 Further review of the treatment sheets revealed no documentation and/or interventions noted by the nurse. During an interview on 5/23/24 at 12:42 PM, Facility B Clinic Manager stated, “Some patients have orders in place for medications for elevated blood pressures but this patient doesn’t have any medications ordered nor do I see where the nurse notified the doctor”. Record review on 5/23/24 at 10:25 AM of Patient #4’s chart revealed Patient #4 was admitted to the dialysis clinic on 4/09/21 for end stage renal disease (ESRD). Review of the dialysis treatment sheets revealed the following elevated blood pressures post treatment: 5/01/24: BP 213/26 5/08/24: BP 159/138 5/10/24: BP 235/95 5/15/24: BP 217/90 5/17/24: BP 216/106 5/20/24: BP 200/84 Further review of the treatment sheets revealed no documentation and/or interventions noted by the nurse. During an interview on 5/23/24 at 1:09 PM, Facility B Clinic Manager stated, “This patient does not have any medications for elevated blood pressures nor do I see where the nurse notified the doctor”. Facility policy, entitled “Pre-Intra-Post Treatment Data Collection, Monitoring And Nursing Assessment” revealed, “Unless other abnormal parameters are established by the facility Governing Body and documented in the Governing Body Meeting minutes, the following are considered abnormal findings and should be reported to the licensed nurse and documented in the patient’s medical record...Blood Pressure Post Treatment: If the patient can stand: Standing systolic BP greater than 140 mm/Hg (millimeters/mercury) or less than 90 mm/hg; Standing diastolic BP greater than 90 mm/Hg or less than 50 mm/Hg...Sitting BP for patient’s that cannot stand: Sitting systolic BP greater than 140 mm/Hg or less than 90 mm/Hg; Sitting diastolic BP greater than 90 mm/Hg or less than 50 mm/Hg...”.”

    Rule V0543. Standard-level.

The one inspection in the last three years
Inspections on record
DateVisitWhat the record says
May 23, 2024Standard inspection7 deficiencies cited

Is it certified?

  • Medicare-certified dialysis facility, certified or last recertified on Dec 15, 2015.
  • Run for profit.
  • Cited at in the last three years: it didn’t meet a whole condition of Medicare’s rules for dialysis facilities.
  • Chain: DaVita.
Source:

CMS, Dialysis Facility - Listing by Facility. Released Jul 15, 2026. Updated quarterly.

CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.

Has it been penalized?

  • CMS doesn’t publish fines or other penalties for dialysis facilities.
  • None of the deficiencies cited in the last three years came from an inspection that included a complaint investigation.
Source:

CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.

What does it offer?

  • Offers in-center hemodialysis.
  • Doesn’t offer peritoneal dialysis, home hemodialysis training and a shift starting at 5 p.m. or later.
  • 20 dialysis stations.
  • CMS doesn’t publish staffing levels for dialysis facilities.
Source:

CMS, Dialysis Facility - Listing by Facility and Patient survey (ICH CAHPS) - Facility. Released Jul 15, 2026. Updated quarterly.

Who owns it?

  • Part of the DaVita chain, as CMS lists it.
  • CMS publishes no owners file for dialysis facilities, so no other owner is named.
Source:

CMS, Dialysis Facility - Listing by Facility. Released Jul 15, 2026. Updated quarterly.

How do patients fare?

  • CMS rates it 1 of 5 stars (Jan 1, 2021 to Dec 31, 2024).
  • Compared by CMS with what it expects for the facility’s patients: patient survival, as expected; hospital admissions, as expected; readmissions to hospital, as expected; emergency department visits, as expected; emergency department visits within 30 days of a hospital stay, as expected; bloodstream infections, better than expected; patients dialysing through a fistula, as expected; patients on a kidney transplant waitlist, as expected.
  • CMS gives no : “Too few completed survey responses to report.”
Source:

CMS, Dialysis Facility - Listing by Facility and Patient survey (ICH CAHPS) - Facility. Released Jul 15, 2026. Updated quarterly.

Ratings and measures, as published
MeasureRating
Star ratingCMS’s star rating for dialysis facilities, 1 to 51 of 5
Patient survey ratingCMS star rating from its survey of the facility’s in-center hemodialysis patients (ICH CAHPS), 1 to 5Not rated

How does it compare nearby?

  • Of the 6 dialysis facilities CMS lists in Sumter County, 5 have a star rating from CMS: 1 rated 3 of 5, 2 rated 2 of 5, 2 rated 1 of 5.
  • CMS rates this one 1 of 5.
Source:

CMS, Dialysis Facility - Listing by Facility. Released Jul 15, 2026. Updated quarterly.

What the record doesn’t say

  • CMS doesn’t publish fines or other penalties for dialysis facilities, so none are shown.
  • Only complaints that led to a citation appear; complaints that didn’t aren’t published.
  • QCOR says it has no dialysis inspection reports after February 19, 2026, while it moves to a new system: a later inspection is not shown yet.
  • CMS doesn’t publish staffing levels for dialysis facilities.
  • CMS publishes no owners file for dialysis facilities: the chain it lists is the only owner named.

Sources

If you believe something here is wrong, a correction starts with the agency whose record this copies: CMS. CMS’s own record is on Care Compare. If Hearth Record copied something wrongly, it will fix it and log the correction publicly, with its date: how corrections work.

Source:

This copy of the record was made on Oct 30, 2026.

From the facility

The public record above comes first. Anything the facility adds will appear here, below it, and say who wrote it.

Replies

None. Replies aren’t open yet. When they open, the facility will be able to answer any finding for free, and the reply will show beside that finding, unedited and dated.

Paid listing

None. Paid listings aren’t open yet. When they open, anything paid for will say “Paid by the facility”, and paying will never change a finding, a rating or the order of results.

How to read a record

Four things every record does, shown on an example record made up for this guide.

An example record, made up for this guide

An example nursing home

Made up for this guide: no real place is shown

Not fully inspected in over two years (CMS flag)

11 health citations at the latest inspection cycle

The state average is 14.3.

Source:

CMS, State and US Averages and Health Deficiencies. Released Oct 28, 2026. Updated monthly.

From the homeNone yet. Replies and paid listings aren’t open, and when they open they will sit here, below the record.

1 of 4

Every fact names its source.

Who published it, when, and how often it changes sit beside each fact, with a link to the agency’s own file.

Sign in

A free account keeps your watch list, shortlists, comparisons and saved searches on every device, and can email you when something you watch changes. Browsing never needs one.