Hearth Record

Usrc Travelers Rest Dialysis

A dialysis facility in Travelers Rest, South Carolina 29690

36 S Main St, Travelers Rest, South Carolina 29690. (864) 660-2050.

CMS’s own record, on Care Compare

Watch and the shortlist are kept with a free account, on every device. Your watch list. CMS’s own record is on Care Compare.

The short answer

Record last released by CMS on Oct 14, 2026.

The last 24 months 5 deficiencies in 1 month of the last 36. Last cited Jul 2024. Most serious: Standard-level. Every month

Each figure’s source sits beside it, in its section below.

What these words mean3
Star ratings
CMS rates some kinds of place from 1 to 5 stars, more stars meaning better on CMS’s own measures for that kind: for a nursing home, its health inspections, staffing and quality measures. A rating is CMS’s summary of those measures; it doesn’t promise good care. Source: CMS, Care Compare and the Five-Star Quality Rating System.
Inspection (survey)
A visit by state inspectors, often unannounced, who check a place against the rules it must meet. For nursing homes and other places Medicare pays, CMS calls these visits surveys: a standard survey of a nursing home comes at least every 15 months, and a complaint survey whenever a complaint calls for one. Source: CMS; 42 CFR 488.308.
Deficiency, citation, violation
What inspectors write up when a place didn’t meet a rule: the rule, what they saw, and when. CMS calls it a deficiency; states may say citation or violation. It is the inspectors’ finding, not a court’s, and the place is usually asked for a plan to correct it. Source: CMS, statement of deficiencies (Form CMS-2567); each state’s licensing agency.

What did inspectors find?

The last inspection on record was on Jul 3, 2024: a standard inspection.

5 deficiencies cited in the last three years.

Source:

CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 14, 2026. Updated monthly.

When those deficiencies happened

5 deficiencies in 1 month of the last 36. Last cited Jul 2024. Most serious: Standard-level. The last 3 years, to Oct 19, 2026.

5 deficiencies by month over the last 3 years. Each cell is one month.
JanFebMarAprMayJunJulAugSepOctNovDec
2023 NovDec
2024 JanFebMarAprMayJunJulAugSepOctNovDec
2025 JanFebMarAprMayJunJulAugSepOctNovDec
2026 JanFebMarAprMayJunJulAugSepOct

Hover or focus a month to read it.

No visit on record Visited, nothing cited A stronger orange is more serious, on its source’s own levels, read onto four bands: from the least serious it publishes to the most
Source:

Hearth Record drew this from the dates and levels in the source’s own records.

Each deficiency, as cited

Rule titles as CMS’s inspectors cite them, set in sentence case.

Source:

CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 14, 2026. Updated monthly.

Jul 3, 2024: standard inspection5 deficiencies
  • Ic - Wear Gloves/Hand Hygiene

    The inspectors’ words, 364 words

    “IC-WEAR GLOVES/HAND HYGIENE CFR(s): 494.30(a)(1) Wear disposable gloves when caring for the patient or touching the patient’s equipment at the dialysis station. Staff must remove gloves and wash hands between each patient or station. This Standard is not met as evidenced by: 28883 Based on observations, interviews, and review of the facility policy “Hand Hygiene”, two of three Patient Care Technicians (PCTs) observed, PCTs #2 and #3, failed to perform hand hygiene to prevent potential cross contamination. The findings include: Observation on 7/1/24 at 9:02 AM of the treatment room floor revealed Patient Care Technician (PCT) #3 at station #5, machine #9, caring for a patient whose treatment had finished. PCT #3 donned gloves, took the patient’s temperature with a thermometer, documented the result on the hemodialysis machine screen then went to a clean supply cart and retrieved an alcohol pad and used it to clean the thermometer. PCT #3 did not remove gloves and perform hand hygiene after touching the hemodialysis machine and/or prior to going to the clean supply cart. During an interview on 7/1/24 at 9:25 AM, PCT #3 stated s/he usually tries to perform hand hygiene before leaving the station. Observation on 7/1/24 at 10:10 AM of the treatment room floor revealed PCT #2 at station #7, machine #11. PCT #2 with gloved hands removed a Band-Aid from the patient’s arm, folded the Band-Aid, and placed it in the trash. PCT #2 then opened a needle pack and removed 2 dialysis needles. PCT #2 then felt the patient’s access (fistula), listened to the access with a stethoscope (cleaning the stethoscope before and after with an alcohol pad), then picked up the needles with the same gloves, set them down, and placed a tourniquet on the patient’s arm. PCT #2 had not removed the gloves and/or performed hand hygiene after removing the Band-Aid. During an interview on 7/1/24 at 10:32 AM, PCT #2 verified the observation. Review on 7/2/24 at 2:44 PM of the facility policy, entitled “Hand Hygiene”, revised 08/2020, revealed hand hygiene will be performed before and after touching a patient, before clean/aseptic procedure, after body fluid exposure risk, and after touching patient surroundings to include the dialysis machine.”

    Rule V0113. Standard-level.

  • Ic - Transducer Protectors: Not Wetted/Changed

    The inspectors’ words, 401 words

    “IC-TRANSDUCER PROTECTORS-NOT WETTED/CHANGED CFR(s): 494.30(a)(1)(i) Use external venous and arterial pressure transducer filters/protectors for each patient treatment to prevent blood contamination of the dialysis machines’ pressure monitors. If the external transducer protector becomes wet, replace immediately and inspect the protector. If fluid is visible on the side of the transducer protector that faces the machine, have qualified personnel open the machine after the treatment is completed and check for contamination. This includes inspection for possible blood contamination of the internal pressure tubing set and pressure sensing port. If contamination has occurred, the machine must be taken out of service and disinfected using either 1:100 dilution of bleach (300-600 mg/L free chlorine) or a commercially available, EPA-registered tuberculocidal germicide before reuse. Change filters/protectors between each patient treatment, and do not reuse them. Internal transducer filters do not need to be changed routinely between patients. This Standard is not met as evidenced by: 28883 Based on interview and review of facility policy, the dialysis facility failed to ensure one of two nursing staff, Registered Nurse (RN) #2, interviewed about infection control measures for a wetted transducer protector was not knowledgeable about the action to take if blood was noted on the transducer protector side facing the machine. The findings include: During an interview on 7/3/24 at 9:00 AM, RN #2 was asked what action to take if the transducer protector was observed to have blood on the front side. RN #2 stated s/he would change the transducer protector, inspect the side facing the machine and if there was blood/red visible on the backside, s/he would pull the machine and disinfect it with bleach. When asked to elaborate, the nurse stated s/he would pull the machine immediately and have the Patient Care Technicians bleach disinfect the machine before it could be used again. When informed this was not the correct answer, RN #2 asked if s/he could find out the correct answer. RN #2 returned and reported that the Biomedical Technician would be notified and the machine taken out of service after the dialysis treatment was completed. Review on 7/3/24 at 9:26 AM of the facility policy, entitled “Intradialytic Monitoring of Patient”, revised 09/2020, revealed information that “If transducer filter becomes wet, replace immediately. Inspect the side of the protector that faces the machine. “...If fluid is visible, biomed tech will be notified and machine taken out of service after dialysis treatment is completed...”.”

    Rule V0120. Standard-level.

  • Ic - Clean, Disinfect Surfaces & Equipment/Written Protocols

    The inspectors’ words, 235 words

    “IC-DISINFECT SURFACES/EQUIP/WRITTEN PROTOCOL CFR(s): 494.30(a)(4)(ii) [The facility must demonstrate that it follows standard infection control precautions by implementing- (4) And maintaining procedures, in accordance with applicable State and local laws and accepted public health procedures, for the-] (ii) Cleaning and disinfection of contaminated surfaces, medical devices, and equipment. This Standard is not met as evidenced by: 22313 Based on observation, interview and review of facility policy, the dialysis facility failed to ensure one of three PCTs observed, Patient Care Technician (PCT) #2, did not disinfect the prime waste bucket after patient use. Findings include: Observation on 07/01/24 at 11:05 AM showed Patient Care Technician PCT#2 dumped the saline from the prime waste container after patient treatment. PCT#2 returned the prime waste container to the hemodialysis machine without sanitizing it inside or out. During an interview on 07/01/24 at 11:15 AM, PCT#2 stated, “I usually just return it to the machine then go over the whole machine before putting on the next patient”. After the interview, PCT#2 was observed setting up the machine for the next patient without disinfection of the prime waste bucket. Review of the facility’s policy titled, “Disinfection and Cleaning of Dialysis Machine Equipment,” showed that staff are to disinfect all surfaces of the prime waste bucket, inside and out, with a cloth moistened in a solution of 1 part bleach to 100 parts water before returning it the to the dialysis machine.”

    Rule V0122. Standard-level.

  • Carbon Adsorption - Action If First Test Positive

    The inspectors’ words, 309 words

    “CARBON ADSORP-ACTION IF FIRST TEST + CFR(s): 494.40(a) 5.2.5 Carbon adsorption: action if first test positive When samples from the first sampling port are positive for chlorine or chloramine, operation may be continued for a short time (up to 72 hours) until a replacement bed is installed, provided that samples from the second sampling port remain negative. The replacement bed should be placed in the second position, and the existing second bed should be moved to the first position to replace the exhausted bed. If it is not possible to rotate the position of the beds, both beds should be replaced. This Standard is not met as evidenced by: 22313 Based on observation, interview and review of facility policy, the dialysis facility failed to ensure one of two staff observed performing the Total Chlorine test, Patient Care Technician (PCT) #1, was unable to verbalize the appropriate port to check for chlorine breakthrough. Findings include: During observation on 07/01/24 at 10:50 AM, Patient Care Technician (PCT)#1 and Registered Nurse (RN)#1 performed the Total Chlorine test correctly. PCT#1 performed the test on the water on the first carbon port. PCT#1 was then asked, “What would you do if the test failed?” PCT#1 stated the next step was to go to the second carbon port and repeat the test. PCT#1 began looking for the second port between the two carbon tanks. PCT#1 then came back to the bank of ports. PCT#1 then pointed to the water softener port and indicated that is where she would go for the test. RN#2 was asked if that was the right port to check and she said “No”, that s/he would check the carbon polisher port. The test procedure is posted in the water room and the water ports are labeled. During an interview on 07/01/24 at 11:12 AM, PCT#1 stated, “I got confused. I’m sorry.””

    Rule V0197. Standard-level.

  • Pe - Equipment Maintenance - Manufacturer’S Dfu

    The inspectors’ words, 240 words

    “PE-EQUIPMENT MAINTENANCE-MANUFACTURER’S DFU CFR(s): 494.60(b) The dialysis facility must implement and maintain a program to ensure that all equipment (including emergency equipment, dialysis machines and equipment, and the water treatment system) are maintained and operated in accordance with the manufacturer’s recommendations. This Standard is not met as evidenced by: 22313 Based on record review, interview and review of facility policy, the dialysis facility failed to ensure the weekly documentation for weekly machine bleach disinfection was completed for 3 of 15 hemodialysis machines reviewed. (Dialysis machines #1, #10 and #12). Findings include: Record review on 07/03/24 at 12:30 PM of the documentation for bleach disinfection of the hemodialysis machines showed missed dates of disinfection. Documentation for Machine #1 showed no bleach disinfection for 05/07/24, 05/14/24, 06/11/24 and 06/18/24. Machine #10 showed no documentation of bleach disinfection for 05/14/24, 05/21/24, 06/4/24, 06/11/24 and 06/18/24. Machine #12 showed no documentation of bleach disinfection for 05/14/24 and 06/18/24. During an interview on 07/03/24 at 1:30 PM, the Biomedical Technician (BMT) stated, “I talked to staff. They said they did it, just did not document it correctly. I am going to take care of that. All fifteen of the machines were missing documentation for the bleach documentation.” Review of the facility’s policy titled, “Disinfection Protocols,” dated 04/2022, showed that once weekly, the dialysis machine(s) must go through an acid rinse followed by bleach disinfection. Dialysis machine disinfection must be documented on the Machine Disinfection Log.”

    Rule V0403. Standard-level.

The one inspection in the last three years
Inspections on record
DateVisitWhat the record says
Jul 3, 2024Standard inspection5 deficiencies cited

Is it certified?

  • Medicare-certified dialysis facility, certified or last recertified on Nov 20, 2015.
  • Run for profit.
  • No deficiency on record in the last three years.
  • Chain: US Renal Care, Inc.
Source:

CMS, Dialysis Facility - Listing by Facility. Released Jul 15, 2026. Updated quarterly.

CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 14, 2026. Updated monthly.

Has it been penalized?

  • CMS doesn’t publish fines or other penalties for dialysis facilities.
  • None of the deficiencies cited in the last three years came from an inspection that included a complaint investigation.
Source:

CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 14, 2026. Updated monthly.

What does it offer?

  • Offers in-center hemodialysis.
  • Doesn’t offer peritoneal dialysis, home hemodialysis training and a shift starting at 5 p.m. or later.
  • 13 dialysis stations.
  • CMS doesn’t publish staffing levels for dialysis facilities.
Source:

CMS, Dialysis Facility - Listing by Facility and Patient survey (ICH CAHPS) - Facility. Released Jul 15, 2026. Updated quarterly.

Who owns it?

  • Part of the US Renal Care, Inc. chain, as CMS lists it.
  • CMS publishes no owners file for dialysis facilities, so no other owner is named.
Source:

CMS, Dialysis Facility - Listing by Facility. Released Jul 15, 2026. Updated quarterly.

How do patients fare?

  • CMS rates it 3 of 5 stars (Jan 1, 2021 to Dec 31, 2024).
  • Compared by CMS with what it expects for the facility’s patients: patient survival, as expected; hospital admissions, as expected; readmissions to hospital, as expected; emergency department visits, as expected; emergency department visits within 30 days of a hospital stay, as expected; bloodstream infections, better than expected; patients dialysing through a fistula, as expected; patients put on a kidney transplant waitlist in their first year of dialysis, as expected; patients on a kidney transplant waitlist, as expected.
  • CMS gives no : “Too few completed survey responses to report.”
Source:

CMS, Dialysis Facility - Listing by Facility and Patient survey (ICH CAHPS) - Facility. Released Jul 15, 2026. Updated quarterly.

Ratings and measures, as published
MeasureRating
Star ratingCMS’s star rating for dialysis facilities, 1 to 53 of 5
Patient survey ratingCMS star rating from its survey of the facility’s in-center hemodialysis patients (ICH CAHPS), 1 to 5Not rated

How does it compare nearby?

  • Of the 12 dialysis facilities CMS lists in Greenville County, 10 have a star rating from CMS: 1 rated 5 of 5, 3 rated 4 of 5, 5 rated 3 of 5, 1 rated 2 of 5.
  • CMS rates this one 3 of 5.
Source:

CMS, Dialysis Facility - Listing by Facility. Released Jul 15, 2026. Updated quarterly.

What the record doesn’t say

  • CMS doesn’t publish fines or other penalties for dialysis facilities, so none are shown.
  • Only complaints that led to a citation appear; complaints that didn’t aren’t published.
  • QCOR says it has no dialysis inspection reports after February 19, 2026, while it moves to a new system: a later inspection is not shown yet.
  • CMS doesn’t publish staffing levels for dialysis facilities.
  • CMS publishes no owners file for dialysis facilities: the chain it lists is the only owner named.

Sources

If you believe something here is wrong, a correction starts with the agency whose record this copies: CMS. CMS’s own record is on Care Compare. If Hearth Record copied something wrongly, it will fix it and log the correction publicly, with its date: how corrections work.

Source:

This copy of the record was made on Oct 19, 2026.

From the facility

The public record above comes first. Anything the facility adds will appear here, below it, and say who wrote it.

Replies

None. Replies aren’t open yet. When they open, the facility will be able to answer any finding for free, and the reply will show beside that finding, unedited and dated.

Paid listing

None. Paid listings aren’t open yet. When they open, anything paid for will say “Paid by the facility”, and paying will never change a finding, a rating or the order of results.

How to read a record

Four things every record does, shown on an example record made up for this guide.

An example record, made up for this guide

An example nursing home

Made up for this guide: no real place is shown

Not fully inspected in over two years (CMS flag)

11 health citations at the latest inspection cycle

The state average is 14.3.

Source:

CMS, State and US Averages and Health Deficiencies. Released Oct 28, 2026. Updated monthly.

From the homeNone yet. Replies and paid listings aren’t open, and when they open they will sit here, below the record.

1 of 4

Every fact names its source.

Who published it, when, and how often it changes sit beside each fact, with a link to the agency’s own file.

Sign in

A free account keeps your watch list, shortlists, comparisons and saved searches on every device, and can email you when something you watch changes. Browsing never needs one.