Fresenius Kidney Care Spartanburg
A dialysis facility in Spartanburg, South Carolina 29307
128 Dillon Dr, Spartanburg, South Carolina 29307. (864) 587-1507.
Watch and the shortlist are kept with a free account, on every device. Your watch list. CMS’s own record is on Care Compare.
The short answer
Record last released by CMS on Oct 28, 2026.
- 3of 5 CMS’s star rating
- 3of 5 patient survey rating
- 6 deficiencies cited in the last three years
- 24 dialysis stations
Each figure’s source sits beside it, in its section below.
What these words mean3
- Star ratings
- CMS rates some kinds of place from 1 to 5 stars, more stars meaning better on CMS’s own measures for that kind: for a nursing home, its health inspections, staffing and quality measures. A rating is CMS’s summary of those measures; it doesn’t promise good care. Source: CMS, Care Compare and the Five-Star Quality Rating System.
- Inspection (survey)
- A visit by state inspectors, often unannounced, who check a place against the rules it must meet. For nursing homes and other places Medicare pays, CMS calls these visits surveys: a standard survey of a nursing home comes at least every 15 months, and a complaint survey whenever a complaint calls for one. Source: CMS; 42 CFR 488.308.
- Deficiency, citation, violation
- What inspectors write up when a place didn’t meet a rule: the rule, what they saw, and when. CMS calls it a deficiency; states may say citation or violation. It is the inspectors’ finding, not a court’s, and the place is usually asked for a plan to correct it. Source: CMS, statement of deficiencies (Form CMS-2567); each state’s licensing agency.
What did inspectors find?
The last inspection on record was on Jan 24, 2024: a standard inspection.
6 deficiencies cited in the last three years.
CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.
When those deficiencies happened
6 deficiencies in 1 month of the last 36. Last cited Jan 2024. Most serious: Standard-level. The last 3 years, to Oct 30, 2026.
| Jan | Feb | Mar | Apr | May | Jun | Jul | Aug | Sep | Oct | Nov | Dec | |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 2023 | Nov | Dec | ||||||||||
| 2024 | Jan | Feb | Mar | Apr | May | Jun | Jul | Aug | Sep | Oct | Nov | Dec |
| 2025 | Jan | Feb | Mar | Apr | May | Jun | Jul | Aug | Sep | Oct | Nov | Dec |
| 2026 | Jan | Feb | Mar | Apr | May | Jun | Jul | Aug | Sep | Oct |
Hover or focus a month to read it.
Hearth Record drew this from the dates and levels in the source’s own records.
Each deficiency, as cited
Rule titles as CMS’s inspectors cite them, set in sentence case.
CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.
Jan 24, 2024: standard inspection6 deficiencies
-
Ic - Sanitary Environment
The inspectors’ words, 176 words
“IC-SANITARY ENVIRONMENT CFR(s): 494.30 The dialysis facility must provide and monitor a sanitary environment to minimize the transmission of infectious agents within and between the unit and any adjacent hospital or other public areas. This Standard is not met as evidenced by: 22313 Based on observations and interviews, the facility failed to ensure that a sanitary environment is maintained in the patient care area. The findings are: On 1/23/24 at 12:05 PM, observations of the patient in dialysis station 9 showed the patient had placed a large bag of personal items on the shelf behind the dialysis treatment chair. At 3:14 PM, the patient finished the dialysis treatment and left with the bag. Patient Care Technician (PCT)#3 cleaned dialysis station 9 preparing for the next patient but neglected to clean the shelf behind the dialysis treatment chair. At 12:15 PM, PCT#3 reported “Oh, I didn’t know that he put anything back there!.” Facility policy, entitled, ‘Infection Control Guidelines’, reads, “Supplies or patient’s belongings should not be kept or stored behind the machine at the patient station”.”
-
Dialysate Proportioning - Monitor Ph/Conductivity
The inspectors’ words, 528 words
“DIALYS PROPORT-MONITOR PH/CONDUCTIVITY CFR(s): 494.40(a) 5.6 Dialysate proportioning: monitor pH/conductivity It is necessary for the operator to follow the manufacturer’s instructions regarding dialysate conductivity and to measure approximate pH with an independent method before starting the treatment of the next patient. This Standard is not met as evidenced by: 28883 Based on observations, interview, and review of the facility’s policies, “Checking pH of Final Dialysate with Precision pH Control Paper” and “Pre-Treatment Safety Checks Procedure”, two of two Patient Care Technicians (PCTs) observed for initiation of dialysis treatments, (PCT #1 and #2) failed to either perform the independent pH check accurately or perform the independent pH check at all before attempting to start a patient treatment. The findings included: Observations on 1/22/24 at 11:30 AM revealed Patient Care Technician #2 at dialysis machine 6 in dialysis station 12 preparing the hemodialysis machine for patient treatment. At 11:37 AM, PCT #2 placed a pH test strip under the dialysis machine drain line at the wall box and wetted the strip with the fluid. PCT #2 compared the color of the strip to those shown on the pH strip container. During an interview on 1/22/24 at 12:01 PM, PCT #2 stated she/he was performing the independent pH check by getting a sample from the drain line at the wall box. Review on 1/23/24 at 11:18 AM of the facility policy, provided by the dialysis clinic, entitled, “Checking pH of Final Dialysate with Precision pH Control Paper” revealed staff are to “...Obtain sample from the blue Hanson connector of the dialysis machine and place in plastic cup...Dip the test strip into the solution to be tested about 1/2 (inch) for 1-2 seconds...Match color of strip to the color chart...”. Observations on 1/22/24 between 12:22 and 12:41 PM revealed Patient Care Technician (PCT) #1 and Registered Nurse (RN) #1 at dialysis machine 15 in dialysis station 17 preparing the patient and hemodialysis machine for dialysis treatment. At 12:43 PM, PCT #1 disconnected the dialysis lines, rinsed the lines of saline, and handed them to the nurse to attach to the patient’s central venous catheter ports. PCT #1 verified they were getting ready to start the patient’s treatment. When the surveyor asked if PCT #1 had completed all steps necessary before starting the patient’s dialysis treatment, PCT #1 stated that the dialysis machine does its own independent pH check. When PCT #1 was asked to show where the data had been documented, PCT #1 reported the dialysis machine showed that an independent conductivity check had been completed, but not an independent pH check. RN #1 who was present for the interview stated “They usually do the pH check”. Review on 1/24/24 at 4:16 PM of the facility policy, provided by the dialysis clinic, entitled, “Pre-Treatment Safety Checks Procedure” revealed that two direct patient care staff, prior to treatment initiation are to “...Verify conductivity and pH readings: To verify conductivity and pH readings, both staff watch the independent test being performed at the same time or if the test is not performed and results observed by both people, the second person must perform the test a second time to verify the initial test results...”.”
-
Pe - Safe, Functional, Comfortable Environment
The inspectors’ words, 347 words
“PE-SAFE/FUNCTIONAL/COMFORTABLE ENVIRONMENT CFR(s): 494.60 The dialysis facility must be designed, constructed, equipped, and maintained to provide dialysis patients, staff, and the public a safe, functional, and comfortable treatment environment. This Standard is not met as evidenced by: 22313 Based upon observations, record review, and interview(s), the trash cans are overflowing, clinic floor is dirty, and expired supplies are found. The findings are: On 1/22/24 at 11:15 AM, observations in the dialysis treatment room revealed overflowing trash cans in 2 of 3 aisles with soiled gloves and other trash coming out of the top of the trash container. PCT#2’s responded “Not me! It’s always like this.” Facility Policy, entitled, “General Cleanliness and Infection, reads, “All areas must be kept clean and organized, including but not limited to the treatment area. Walkways must be kept clear of debris and free of clutter”. On 1/22/24 at 11:42 AM, during the initial tour, observations showed three suture removal kits expired 9/30/23. Registered Nurse (RD) #2 verified the finding. Facility Policy, entitled, “Storage of Supplies”, reads, “Supplies must be rotated First in-First Out (FIFO) to ensure products maintain quality and do not expire. Appropriately dispose of items that have reached the expiration date”. Observation on 1/22/24 at 11:50 AM of the Emergency “Crash” cart revealed the crash box was unlocked with 3 vials of Atropine inside along with other medical supplies. The Emergency “Go” box for emergency evacuations is unlocked and open with medications/supplies inside. Registered Nurse (RN) #1 reported “The Pharmacist was here last week and she had trouble getting it closed so just left it open”. Facility policy entitled “Medication Preparation/Administration under ‘Securement’ reads: “All medications will be kept in a locked cabinet except when in use”. On 1/23/24 at 12:40 PM, observations in the dialysis treatment room showed Registered Nurse #2 going from dialysis station to dialysis station checking breath sounds with the individual stethoscope that stays hanging at each station. RN #2 did not sanitize the stethoscope prior to or after use on each patient. Patient Care Technician #5 reported “I guess we really ought to do that”.”
-
Pe - Hemodialysis Patients In View During Treatments
The inspectors’ words, 180 words
“PE-HD PTS IN VIEW DURING TREATMENTS CFR(s): 494.60(c)(4) Patients must be in view of staff during hemodialysis treatment to ensure patient safety, (video surveillance will not meet this requirement). This Standard is not met as evidenced by: 22313 Based upon observation(s) and interview(s), the facility failed to ensure patients’ access ports are uncovered at all times. The findings are: On 1/23/24 at 9:55 AM, observations of the random patient at dialysis station 13 had a blanket pulled up over his head completely covering the access site. The patient was observed intermittently over 3 hours while Registered Nurse (RN)#2 and Patient Care Technician (PCT)#2 returned again and again to check the dialysis machine, but neither staff uncovered the patient’s fistula access at any time. At 1:00 PM, when the patient’s treatment was ending, PCT#2 reported “Oh, he just likes to sleep while he’s dialyzing. I can pull the blanket down, but he will just pull it up again.” Facility policy, entitled, ‘Patient Assessment and Monitoring,’ reads, “Ensure each patient’s face is visible and uncovered. Ensure access remains uncovered throughout the treatment”.”
-
Assess B/P & Fluid Management Needs
The inspectors’ words, 179 words
“PA-ASSESS B/P, FLUID MANAGEMENT NEEDS CFR(s): 494.80(a)(2) The patient’s comprehensive assessment must include, but is not limited to, the following: Blood pressure, and fluid management needs. This Standard is not met as evidenced by: 22313 Based on record review and interview, the facility failed to ensure patient(s) are monitored regularly per policy for 1 of 15 patients. (Patient #2) The findings are: On 1/12/24, Patient #2 underwent a 4 hour dialyzing treatment. Review of the patient’s medical record showed the patient’s blood pressure was checked at the following times: 1/10/24: 12:39, 13:44 by Registered Nurse #3 with a 65 minute gap between monitoring the blood pressure of the patient. 1/12/24: 13:32, 14:28, 15:53 by Patient Care Technician #5 with a 56 minute and an 85 minute gap between monitoring the blood pressures of the patient. Facility Policy, entitled, “Patient Assessment and Monitoring” read, “Obtain blood pressure and pulse rate every 30 minutes or more as needed but not to exceed 45 minutes or per state regulations.” The Facility Manager was interviewed 1/24/24 at 1:00 PM and confirmed the findings.”
-
Preconfig Hd Sys -Testing Water/Dialysate Follow Dfu/Fda
The inspectors’ words, 274 words
“H-PRECONFIG HD SYS-TEST H20/DIALY PER DFU/FDA CFR(s): 494.100(c)(1)(v) Services include, but are not limited to, the following: testing of the water and dialysate system in accordance with- (A) The recommendations specified in the manufacturers’ instructions; and (B) The system’s FDA-approved labeling for preconfigured systems designed, tested, and validated to meet AAMI quality (which includes standards for chemical and chlorine/chloramine testing) water and dialysate. This Standard is not met as evidenced by: 28883 Based on record review, interview, and review of the facility policy, “Nxstage PureFlow SL”, the dialysis clinic home therapy nursing staff failed to ensure 8 of 9 home hemodialysis patients had a tap water chemical analysis documented in the past year. The findings included: Review on 1/23/24 and 1/24/24 of the facility’s water chemical analysis reports and home hemodialysis patient dialysate culture and endotoxin reports revealed no tap water AAMIs had been provided. During an interview on 1/24/24 at 9:25 AM, the Home Therapy Program Manager stated they had not gotten all the home hemodialysis patients tap water AAMIs annually, and she/he believed all the home hemodialysis patients were on municipal/city water. Review on 1/24/24 from 9:45 AM through 10:20 AM revealed 8 of the 9 home hemodialysis patients in the clinic did not have documented chemical analyses of their tap water in the past year. Review on 1/24/24 at 2:24 PM of the facility policy provided by the dialysis clinic, entitled, “NxStage PureFlow SL Testing for Water Quality-Chemical”, revealed, that Source water (tap) that does not exceed the NxStage Pureflow SL source water limits would need a chemical analysis for contaminants initially and annually if using municipal or city water sources.”
The one inspection in the last three years
| Date | Visit | What the record says |
|---|---|---|
| Jan 24, 2024 | Standard inspection | 6 deficiencies cited |
Is it certified?
- Medicare-certified dialysis facility, certified or last recertified on May 16, 2012.
- Run for profit.
- No For hospices, home health agencies, hospitals and dialysis facilities, CMS writes deficiencies at two levels. Standard is the usual one; condition-level is the more serious, when a problem is serious enough that the provider doesn’t meet a whole condition of taking part in Medicare. Source: CMS, State Operations Manual. deficiency on record in the last three years.
- Chain: Fresenius Medical Care.
CMS, Dialysis Facility - Listing by Facility. Released Jul 15, 2026. Updated quarterly.
CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.
Has it been penalized?
- CMS doesn’t publish fines or other penalties for dialysis facilities.
- None of the deficiencies cited in the last three years came from an inspection that included a complaint investigation.
CMS, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies. Released Oct 28, 2026. Updated monthly.
What does it offer?
- Offers in-center hemodialysis, peritoneal dialysis and home hemodialysis training.
- Doesn’t offer a shift starting at 5 p.m. or later.
- 24 dialysis stations.
- CMS doesn’t publish staffing levels for dialysis facilities.
- In CMS’s survey, patients rate its staff 1 of 5.
CMS, Dialysis Facility - Listing by Facility and Patient survey (ICH CAHPS) - Facility. Released Jul 15, 2026. Updated quarterly.
Who owns it?
- Part of the Fresenius Medical Care chain, as CMS lists it.
- CMS publishes no owners file for dialysis facilities, so no other owner is named.
CMS, Dialysis Facility - Listing by Facility. Released Jul 15, 2026. Updated quarterly.
How do patients fare?
- CMS rates it 3 of 5 stars (Jan 1, 2021 to Dec 31, 2024).
- Compared by CMS with what it expects for the facility’s patients: patient survival, as expected; hospital admissions, as expected; readmissions to hospital, as expected; blood transfusions, as expected; emergency department visits, as expected; emergency department visits within 30 days of a hospital stay, as expected; bloodstream infections, better than expected; patients dialysing through a fistula, as expected; patients put on a kidney transplant waitlist in their first year of dialysis, as expected; patients on a kidney transplant waitlist, as expected.
- Patients rate it 3 of 5 in CMS’s survey of in-center hemodialysis patients (36 interviews, Oct 18, 2024 to Jul 11, 2025): 56% rated the facility 9 or 10 out of 10.
CMS, Dialysis Facility - Listing by Facility and Patient survey (ICH CAHPS) - Facility. Released Jul 15, 2026. Updated quarterly.
| Measure | Rating |
|---|---|
| Star ratingCMS’s star rating for dialysis facilities, 1 to 5 | 3 of 5 |
| Patient survey ratingCMS star rating from its survey of the facility’s in-center hemodialysis patients (ICH CAHPS), 1 to 5 | 3 of 5 |
How does it compare nearby?
- Of the 9 dialysis facilities CMS lists in Spartanburg County, 9 have a star rating from CMS: 1 rated 5 of 5, 4 rated 3 of 5, 4 rated 2 of 5.
- CMS rates this one 3 of 5.
CMS, Dialysis Facility - Listing by Facility. Released Jul 15, 2026. Updated quarterly.
What the record doesn’t say
- CMS doesn’t publish fines or other penalties for dialysis facilities, so none are shown.
- Only complaints that led to a citation appear; complaints that didn’t aren’t published.
- QCOR says it has no dialysis inspection reports after February 19, 2026, while it moves to a new system: a later inspection is not shown yet.
- CMS doesn’t publish staffing levels for dialysis facilities.
- CMS publishes no owners file for dialysis facilities: the chain it lists is the only owner named.
Sources
-
Centers for Medicare & Medicaid Services, Dialysis Facility - Listing by Facility (23ew-n7w9).
Released Jul 15, 2026 and checked Oct 30, 2026. Updated quarterly. Public domain (U.S. Government work).
-
Centers for Medicare & Medicaid Services, Patient survey (ICH CAHPS) - Facility (59mq-zhts).
Released Jul 15, 2026 and checked Oct 30, 2026. Updated quarterly. Public domain (U.S. Government work).
-
Centers for Medicare & Medicaid Services, QCOR Dialysis Facility (ESRD) 2567 statements of deficiencies (ESRD_2567s_2018_to_2026YTD.xlsx).
Released Oct 28, 2026 and checked Oct 30, 2026. Updated monthly. Public domain (U.S. Government work).
If you believe something here is wrong, a correction starts with the agency whose record this copies: CMS. CMS’s own record is on Care Compare. If Hearth Record copied something wrongly, it will fix it and log the correction publicly, with its date: how corrections work.
This copy of the record was made on Oct 30, 2026.
From the facility
The public record above comes first. Anything the facility adds will appear here, below it, and say who wrote it.
Replies
None. Replies aren’t open yet. When they open, the facility will be able to answer any finding for free, and the reply will show beside that finding, unedited and dated.
Paid listing
None. Paid listings aren’t open yet. When they open, anything paid for will say “Paid by the facility”, and paying will never change a finding, a rating or the order of results.